Loading...
HomeMy WebLinkAbout1901 CASSIA RD; ; CB032642; Permit04-08-2004 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: 04/08/2004 # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Residential Permit Building Inspection Request Line (760) 602-2725 1901 CASSIA RDCBAD COMRES Status: 2150201300 Lot#: 0 Applied: $360,398.00 Construction Type: V1 Entered By: Reference #: A9804388 1 Structure Type: SFA Issued: 2 Bathrooms: 2 Inspect Area: MANZANITA APT- CLUB HOUSE & Orig PC#: ACER'S UNIT)2935 SF CLUB.1249 SF UNIT-336 SF DECKPIan Check#: Permit No: CB032642 Applicant: MANZANITA PARTNERS L L C ATTN: KIM ROTH 1764 SAN DIEGO AVE SAN DIEGO CA 92110 Owner: MANZANITA PARTNERS L L C ATTN: KIM ROTH 1 764 SAN DIEGO AVE SAN DIEGO CA92110 ISSUED 07/28/2003 RMA Approved: 04/08/2004 PC030036 ~-a- "8004/08/04 • 20 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Meter Size Add'l Reel. Water Con. Fee Total Fees: $29,420.20 $1,350.44 $0.00 $877.79 $0.00 $0.00 $75.68 $0.00 $0.00 $0.00 $0.00 $9,900.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Payments To Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Redev Parking Fee Housing Impact Fee Housing In Lieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOTAL PERMIT FEES Date: $0.00 Balance Due: $0.00 $0.00 $6,836.65 $6,559.24 $0.00 $0.00 $0.00 $488.00 $0.00 $0.00 $330.00 $210.00 $0.00 $0.00 $0.00 $0.00 $0.00 $444.00 $2,348.40 $0.00 $29,420.20 $29,420.20 FINAL APPROVAL DATE /"*CLEARANCE SIGNATURE UNSCHEDULED BUILDING INSPECTION DATE v^o-gv\ INSPECTOR PERMIT # QHaj>v*-aL_ PLAN CHECK # JOB ADDRESS t^/^v DESCRIPTION CODE DESCRIPTION ACT COMMENTS \q City of Carlsbad Bldg Inspection Request For: 12/14/2004 Permit* CB032642 Title: MANZANITA APT- CLUB HOUSE & Inspector Assignment: RB Description: MANAGER'S UNIT-(UNIT #200) 935 SF CLUB,1249 SF UNIT- 336 SF DECK-managers unit=ste 200 Type: COMRES Sub Type: Job Address: 1901 CASSIARD Suite: Lot 0 Location: APPLICANT MANZANITA PARTNERS L L C Owner: Remarks: Phone: 6197267591 Inspector: Total Time:Requested By: GABRIEL Entered By: CHRISTINE CD Description 39 Final Electrical Act Comment Associated PCRs/CVs PCR04113 ISSUED MANZANITA APTS-TRUSS-DEFERRED; SUBMITTAL Inspection History Description Act Insp Comments AP RB AP RB NS RB PA RB Date 10/13/2004 23 Gas/Test/Repairs 10/07/2004 17 Interior Lath/Drywall 10/06/2004 17 Interior Lath/Drywall 10/04/2004 17 Interior Lath/Drywall 10/04/2004 44 Rough/Ducts/Dampers 10/01 /2004 17 Interior Lath/Drywall 09/29/2004 16 Insulation 09/28/2004 16 Insulation 09/27/2004 16 Insulation 09/23/2004 14 Frame/Steel/Bolting/Welding 09/23/2004 24 Rough/Topout 09/23/2004 34 Rough Electric 09/23/2004 44 Rough/Ducts/Dampers 09/20/2004 84 Rough Combo 09/15/2004 14 Frame/Steel/Bolting/Welding 09/02/2004 84 Rough Combo 08/26/2004 18 Exterior Lath/Drywall 08/24/2004 18 Exterior Lath/Drywall 08/24/2004 23 Gas/Test/Repairs 08/19/2004 34 Rough Electric 08/18/2004 14 Frame/Steel/Bolting/Welding 08/16/2004 14 Frame/Steel/Bolting/Welding 1ST LAYER OK IN LID AP RB PA RB ON 1ST LAYER PDAP NS NS AP AP AP RB RB RB RB RB NR RB CO RB NS RB PA RB CO ON 1ST FLR ONLY - OK TO INSTALL DROPS @ 1ST FLR AP PD CA PD PA PD U.G. GAS CA RB WILL DO FRMG NR RB nd pins approved for joist change WC RB Inspection List Permit*: CB032642 Type: COMRES Date Inspection Item Inspector Act 12/29/2004 19 12/29/2004 19 12/29/2004 39 12/29/2004 39 12/28/2004 39 12/28/2004 39 12/14/2004 39 10/13/2004 23 10/07/2004 17 10/06/2004 17 10/04/2004 17 10/04/2004 44 10/01/2004 17 09/29/2004 16 09/28/2004 16 09/27/2004 16 09/23/2004 14 09/23/2004 24 09/23/2004 34 09/23/2004 44 09/20/2004 84 09/15/2004 14 09/02/2004 84 08/26/2004 18 08/24/2004 18 08/24/2004 23 08/19/2004 34 08/18/2004 14 08/16/2004 14 08/16/2004 22 08/16/2004 23 08/16/2004 34 08/16/2004 83 08/12/2004 14 08/12/2004 34 08/10/2004 13 08/09/2004 15 08/09/2004 17 08/06/2004 13 08/06/2004 24 08/05/2004 14 08/05/2004 15 08/05/2004 16 Final Structural Final Structural Final Electrical Final Electrical Final Electrical Final Electrical Final Electrical Gas/Test/Repairs Interior Lath/Drywall Interior Lath/Drywall Interior Lath/Drywall Rough/Ducts/Dampers Interior Lath/Drywall Insulation Insulation Insulation Frame/Steel/Bolting/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo Frame/Steel/Bolting/Weldin Rough Combo Exterior Lath/Drywall Exterior Lath/Drywall Gas/Test/Repairs Rough Electric Frame/Steel/Bolting/Weldin Frame/Steel/Bolting/Weldin Sewer/Water Service Gas/Test/Repairs Rough Electric Roof Sheathing/Ext Shear Frame/Steel/Bolting/Weldin Rough Electric Shear Panels/HD's Roof/Reroof Interior Lath/Drywall Shear Panels/HD's Rough/Topout Frame/Steel/Bolting/Weldin Roof/Reroof Insulation RB - - RB - RB RB RB RB RB RB RB RB PD RB RB RB RB RB RB RB RB RB PD PD PD RB RB RB RB RB RB RB PD PD RB RB RB RB RB RB RB RB CO Rl Rl AP Rl CO CO AP AP NS PA AP PA AP NS NS AP AP AP NR CO NS PA AP CA PA CA NR we we we CA AP NS NS CO CO PA NR AP PA PA PA MANZANITA APT- CLUB HOUSE & MANAGER'S UNIT-(UNIT #200) 935 SF CL Comments emr emr 1901 CASSIA AND 1901 CASSIA STE 200 FOR SEO 1ST LAYER OK IN LID ON 1ST LAYER CO ON 1ST FLR ONLY - OK TO INSTALL DROPS® 1ST FLR U.G. GAS WILL DO FRMG nd pins approved for joist change BROKEN TRUSSES - DO NOT LOAD @ THIS AREA FIRE PLACE OK OK TO INSULATE E TOW PARTY OK TO PAPER ONLY @ FIREPLACE Wednesday, December 29,2004 Page 1 of 2 08/05/200417 Interior Lath/Drywall RB PA 08/04/2004 15 Roof/Reroof RB CA 08/03/200413 Shear Panels/HD's RB PA 08/03/200413 Shear Panels/HD's RB PA 08/03/2004 31 Underground/Conduit-Wirin RB PA 07/27/2004 17 Interior Lath/Drywall RB CA 06/24/200413 Shear Panels/HD's RB NR 06/22/2004 14 Frame/Steel/Bolting/Weldin RB PA 06/21/2004 14 Frame/Steel/Bolting/Weldin RB CO 06/17/2004 14 Frame/Steel/Bolting/Weldin RB PA 06/16/200422 Sewer/Water Service RB PA 06/15/200422 Sewer/Water Service RB PA 05/12/200481 Underground Combo RB AP 05/11/2004 11 Ftg/Foundation/Piers RB NR 05/11/2004 31 Underground/Conduit-Wirin RB NR 05/06/2004 21 Underground/Under Floor RB AP 05/06/200422 Sewer/Water Service RB PA 04/23/2004 31 Underground/Conduit-Wirin PS WC 04/22/2004 21 Underground/Under Floor RB PA @ ELECTRIC RM OK D.W. BEHIND FIREPLACE OK @ ELECTRIC RM TO POOL EQUIPMENT ON PRELIM 1STFLR NAILING OK STILL MISSING CO ON FLR NAILING ON FLR NAILING ON H20 - SEE PLANS MISSING SET BACK CERT. sewer only LOW VOLT ONLY @ CLUB HOUSE - SEE JOB PLANS Wednesday, December 29,2004 Page 2 of 2 ' City of Carlsbad Bldg Inspection Request For: 12/29/2004 Permit* CB032642 Title: MANZANITA APT- CLUB HOUSE & Inspector Assignment: RB Description: MANAGER'S UNIT-(UNIT #200) 935 SF CLUB,1249 SF UNIT- 336 SF DECK-managers unit=ste 200 Sub Type: 1901 CASSIA RD Lot Type: COMRES Job Address: Suite: Location: OWNER MANZANITA PARTNERS L L C Owner: Remarks: emr Phone: 6197267591 Inspector: Total Time:Requested By: GABRIEL Entered By: CHRISTINE CD Description 19 Final Structural 39 Final Electrical Act Comment Associated PCRs/CVs PCR04113 ISSUED MANZANITA APTS-TRUSS-DEFERRED; SUBMITTAL Inspection History Comments FOR SEO 1ST LAYER OK IN LID ON 1ST LAYER Date 12/14/2004 10/13/2004 10/07/2004 10/06/2004 10/04/2004 10/04/2004 10/01/2004 09/29/2004 09/28/2004 09/27/2004 09/23/2004 09/23/2004 09/23/2004 09/23/2004 09/20/2004 09/15/2004 09/02/2004 08/26/2004 08/24/2004 08/24/2004 Description 39 Final Electrical 23 Gas/Test/Repairs 17 Interior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 44 Rough/Ducts/Dampers 17 Interior Lath/Drywall 16 Insulation 16 Insulation 16 Insulation 14 Frame/Steel/Bolting/Welding 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers 84 Rough Combo 14 Frame/Steel/Bolting/Welding 84 Rough Combo 18 Exterior Lath/Drywall 18 Exterior Lath/Drywall 23 Gas/Test/Repairs Act CO AP AP NS PA AP PA AP NS NS AP AP AP NR CO NS PA AP CA PA lns| RB RB RB RB RB RB RB PD RB RB RB RB RB RB RB RB RB PD PD PD CO ON 1ST FLR ONLY - OK TO INSTALL DROPS @ 1ST FLR U.G. GAS To wham it may concern: on The staananUa Project, in fact Pitch Plastering recommends their product. The paper used to waterproof the Indlding has a. certain W rating and is onSy suppose to be exposed to the sun for a short period of time be/9re the scratch coat is appUed. We realise that the DrgwaU Subcontractor unU have to screw off att perimeter attachments in Ueu of nutting. We again agree with these terms. However If the DrgwaM is nailed on after the scratch. Con Amor the DrgwaU subcontractor win be heid responsible for any damage to the Plastering operations. fitch .Plastering -in • I 26801 VISta Terrace • Lake Forest. CA 92630 • Tel: <M9> 588-9545 • FaK <9«9) 588-1917 W 92:01 <Bfl WMK-S8-OW AUG.11*2004 D D B CONTRUCTION F.UOd/UU* -i ats j_| mt-Tun j M-02.14 T-M 3*2 GENERAL REPAIR NOTES: LTHIS REPAIR IS FOR DAMAGED TO AS SHOWN. 2.ATTACH 2X8 SCABS (OF NO^ OR BETTER) AS SHOWN TO EACH SIDE OF TRUSS WITH 10D NAILS (0.148" DIA X T LOT) £6?- O.C. 2 ROWS AND CLUSTERED AS SHOWN,. in (M» Mflrt VM(U) -031 11 A» 7IMS • tM 340 2X4DTNa2 tpPOHOMO ^^ C17180 exp.oeoortw AugtMt 10,2004 TTTT QWiinMKh Ift* KM rt1,.-^ AUG.11*2004 0»:58 8586680676 D D B CONTRUCfIONPMCV11AM TIME J<RXttX>AM $2424 P.004/004 •X ni JTW£ Ml II III! !*t or I ? "II * ** i 8 8 TOP CHORD § i i iil Z L. I S; 5 TOP CHORD i I Rug 12 04 04:01p Joe Nelle 18584813363 p.l ARCHITECTURE CONSTRUCTION DC V F. L O P M f! N T f"1 FIELD D1RECTIVE/CLARIFICATION NUMBER 37 MANZANITA APARTMENTS, CARLSBAD, CAPROJ. # CB-12899 8.12.04 To: Continental American Properties, LTD Response: \ Urgent fXJ Normal By Subject: Response to FBC Builders Inc. RF1 Letter 8-10-04 From: Joe Nolle, Architect Please perform the following work. Refer to attached drawing from the structural engineer. Attachments: RFI Letter dated 8-10-04, Response from Structural Engineer Response: Areliilcci Lie. «I'W72. Contactor I.K. -WjaWM. P.O. Box 1183. Del Mat. CA '«OI4-1iM. (H5S) 4SI-2887 flug 12 04 O4:01p Joe Helle 18584813363 p.2 F- (O9Z.)epuftn VO T I flue 12 04 04:01p Joe Melle 68/12/2004 16:12 85B-56B-B842 18584813363 HORCW1TZ TAYLOR KUSH PAGE 83 p.3 K& UP TP CONT iVxW" L6L RIMBOARD t1&TA24CW<& UP TP ran M9TC40CHPBLK ALL PLTHP EDGE& W/2X4 FL/H" BN«EN W/ 4x6. 2-2x4KS J1-;TA24CHP 4x4 ((CONSTRUCTION!) DATE: 8/24/04 NUMBER OF PAGES: 1 TO: DaveDixoo FROM: Frank (Hrianni MESSAGE: Manzanha Apartments This is to confirm that our diywall installers win attach the waflboaidwHh screws only at the interior side of all exterior walls that have previously received a stucco scratch coat 1937A Friendship Drive, El Cajon, Cafifarnia 02020 (619)562-5312 Fax (619) 562-5313