Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; ; CB033404; Permit,J 0 1 -1 5-2004 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 Commercial/lndustriaI Permit Permit No: CB033404 Applicant: STANFORD SIGNS INC 1905 CALLE BARCELONA CBAD TI Sub Type: COMM Lot #: 0 Status: ISSUED $9,960.00 Construction Type: NEW Applied: 12/08/2003 FORUM ERECT AWNING OVER COSWA Plan Approved: 0111 512004 ESCLATOR IST TO 2ND FLOOR Issued: 01/15/2004 Reference #: Entered By: MEL Inspect Area: Plan Check#: 2556 FAIVRE ST. CHULA VISTA, CA 9191 1 61 9-423-6200 Owner: Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee $99.69 $0.00 $64.80 $0.00 $0.00 $2.09 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Recl. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $166.58 Total Fees: $1 66.58 Total Payments To Date: $64.80 Balance Due: $1 01.78 h APPROVAL * I FOR OFFICE USE ONLY PERMIT APPLICATION 0495 lt3/081'03 NO2 g.I $2 Legal Description Lot No. Subdivision Name/Number Unit No. Phase &Gb total # of unit+% 30 CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 [Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requiras the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law city Statelzip City Business License # State License # 4~ b i 7 Name ' Designer Name Address City State/Zip Telephone License Class /z 1 34 cb 0 I have and will rnaintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for whicb this permit is issued. I have and will maintain workers' co pensation, as required by Section 3700 of the Labor Coda, for the performance of the work for which this permit is &ed. My worker's cmid carrier and policy number are: Insurance Company - (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS I$lOOl OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failurn to secure workers' compensation coverage is unlawful. and shall subject an employer to criminal penaltlea and civil fine6 up to one hundred Policy NO. auado 7 6 4 Zsa T Expiration Date thousand dolla I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Businesa and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees. provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year i:if completion, the owner-builder will have the burden of proving that ha did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. 4. number / contractors license number): 5. of work): I am exempt unlder Section I personally plapl to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number / contractors license number): I plan to provide1 portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address I phone I will provide same of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number I type Business and Professions Code for this reason: PROPERTY OWNER SIGNATURE DATE COMPLETE 'THIS SECTION FOR NON-R&S/D€IVTlAL BUILDING PEWITS ONLY- Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Preslay-Tanner Hazardous Substance Account Act? Is the applicant or fulure building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be canstructed within 1,000 feet of the outer boundary of a school site? NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REOUIREMENTS OF 'THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0 YES fi NO 0 YES '@ NO 0 YES I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Coda). LENDER'S NAME - LENDER'S ADDRESS I certify that I have r,sad the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such psrrnit is not commenced within 180 days from the date of such Dermit or if the buildina or work authorized bv such Derrnit is susoended or abandoned at any time after the work is 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 02/24/2004 Permit# CB033404 Inspector Assignment: PS Title: FORUM ERECT AWNING OVER COSWA Description: ESCLATOR 1 ST TO 2ND FLOOR Type: TI Sub Type: COMM Job Address: 1905 CALLE BARCELONA Suite: Lot 0 Location: APPLICANT STANFORD SIGNS INC Owner: Remarks: AWNING FINAL Phone: 9097723766 InsDector: G3 Total Time: Reauested Bv: JEFF CD Description 19 Final Structural Entered By: CHRISTINE TOmment Associated PCRs/CVs PCR03076 PCR03098 PCR03115 PCR03125 PCRO3131 PCR03143 PCR03240 PCR032Li3 PCR04032 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED PENDING ISSUED PENDING FORUM-BLDG I-ARCH REV,PLUMB,; & ELECTRIC THE FORUM @ CARLSBAD; ADD ESCALATOR FORUM-BLDG 1 -REVISE FRAMING; & CONSTRUCTION DETAILS THE FORUM-LIGHT STANDARDS,CURB; & RAMP REVIS.& ELEC TO MONUMENT SI FORUM @ CARLSBAD BLDG # 1; ADD GREASE INTERCEPTOR FORUM-BLDG 1-ELECTRIC REVISION; THE FOURM BLDG # 1 REV ELEC; FOR ESCALATORS & ELEVATORS FOURM BLDG #I REV SHEET TO; SHOW ALLUMINUM STOREFRONT DETAILS BLDG 1, ULTA, RELOCATE TRANSFORMER,PLUMBING VENTS & SATELLlTE COND Inspection History Date Description Act lnsp Comments 02/05/2004 19 Final Structural CO PS S.I. REPORT FALSE 01/26/2004 19 Final Structural CO PS NO S.I. REPORT WELDING 01/21/2004 19 Final Structural CO PS NOSUPERONSITE . I hq KLEINFELDER AI, employee owned company February 24,2004 Project No. 40758 Paul Smith City of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Subject: Project: Report of Welding Inspection Services Carlsbad, California Permit # CB 033404 Dear Mr. Smith: As requested, on February 4, 2004 a representative of our firm visited the subject project to perfom field welding special inspection. Our representative, Robert Turchick, is an ICBO certified welding Special Inspector. We were requested to check welds on canopy cover framing over the escalator at the Forum. The welds were completed prior to our arrival, however all of the welds were single-pass fillet welds less than 5/16” in size. Our representative visually checked the completed welds for size, length, profile, fusion, cracks, and porosity. No rejectable indications were observed or noted. A copy of Robert’s field report is attached. A representative of Stanford Signs and Awning indicated the he had performed the welding and presented his welder’s certifications to our Inspector. Subsequent to our site visit, a copy of the welder’s certification and a welding procedure were faxed to our office. Copies of these are attached. We appreciate the opportunity to be of services. Please contact our office if you have any questicns cr need additional information. Sincerely, KLEINFELDER, INC. LLLC-T-b-Q- Ronald C. Thomson Operations Manager RCT:mlm cc: Jeff Kamark, VCC David LeSage, Stanford Signs Attachments 40758/SDI4L049.doc February 24,2004 Copyright 2004 Kleinfelder, Inc. K L E I N F E L DE R 501 5 Shoreham Place, San Diego, CA 921 22 (858) 320-2000 (858) 320-2001 fax hq KLEINFELDER Construction Observation Report Client / Project No. DFR No. Project Location 1 $?& &1s b IC,* P- c .&,,k Ad Contractors!&& ildg. Permit No.d2!?&3& Reviewed by - Date Reviewed -___-_ Weei-Time Time Arrived - Time Departed ____ 2 w% -- -=ma- ~ wpe of Observations 0 Masonry 0 Batch plant n Foundations n Concrete Welding 0 Reinforcement Steel 0 Fireproofing il Soil 0 Bolting 0 Pre-Post Tensioned Tendon Metal Decking D Other -.~___-___ __ - Documents Referenced F 6Lport items co Acknowledged by ___-- Representing __ Page __ of ___ F-1 19/93) 619-423-8566 P.2 . ._ .- - .. ..... ..... .. ... sE;E320;v391 P . n3/23 L. .. . Appendix A: Sample Welding Procedure Farm WELDING PROCEDURE Feb 20 04 04:47p Stanford Sign 619-423-8566 P -- ENGINEEHNG S& Diego. CA 921 17 , CONSULTANTS ‘T.858;272.0823. F.858.273.53 15. P.3 9 .. .. ! .- .-, i. . . . ._ . . ... Feb 17 04 Cll:49p Stanford Sign 619-423-8566 P.7 SMAW Single DCEP bo . Exhibit 8.1 [Revised, Form E-4, Annex El305 Dl .1-98) WELDER QUALIFICATION TEST RECORD 1 SMAW I Type of Welder Name Jose A. Palacios Identification No. 84971 Welding Procedure Specification No. G ROP 37-A Single Revison No. Date of Yes A-108 to A-108 Variables Processmype Fable 4.10, Item (211 Electrode (single or multiple) Table 4.9, Item (9) CurrentlPolarrty Position (Tablle 4.10, hem (5) Backing (Yes or No) [Table 4.90, Item (S)] Material/Spec.Vable 4.i 0, Item(1)J Base Metal Weld Progression {Table 4.10, Item (811 Thickness: Plate Backing revision RECORD ACTUAL VALUES 1 Q UALl FI CATION Groove Fillet Groove Thickness: (Pipenube) Sch 80 RANG€ I USED IN QUALIFICATION 118 AND THICKE 118 AND THICKER 3116 AND THICKER Result TY Pe Result Type Specimen 1. Side X \Root Passed X Specimen 3 Side 1 X IRoot Passed X Specimen 2 Side X IRoot Passed X ISpecimen 4 Side 1 X (Root Passed X Apperance Fillet Size Fracture Test Root Penetration Macroets h (Describe the location, nature, and size of any crack or tearing of the specimen.) Film Identification I I I - FILLET TEST RESULTS (4.30.2.3 AND 4.30.4.1) RADIOGRAPHIC TEST RESULTS (4.30.3.1) I i I Film Identification Number Results Remarks Number Results Re marks I 2-G 11-G AND 2-G 1 . . -. Growe Fillet Spec. No. Class Filler Metal Fable 4.10, Item(3)j F-NO GaslFlux type Fable 4-10, Item (411 Other 1 6 Inch 14 inch IO and larger 1 l-F AND 2-F 3 4 I NIA I VISUAL INSPECTION Guided Bend Test Results (4.30.5) Acceptable Yes NO 0 r- L I Interpreted b] Test Number Organization Date We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared. and tested in accoordance with the requirements of section 4 of ANSllAWS D1.1,1998 Structural Welding Code-Steel. 1 hereby certify that I was not involved in t Date Tested: 4/23/2001 Signed by Signed by Facility Manager - Rop Director Titfe LQTporale Kepesentattv e Feb 17 04 01:49p w. . Stanford Sign 619-423-8566 THIS CERTIFICATEy IS AN QFFICE FILE COPY. PLEASE HAVE WELDER SIGN ON INDICATED LXNE. Photo ID. Required GJvssment Unbn Htcn schoor c*shiu /R/o/P/p+z-i VOCATlONAL 6 ROP SERVICES lder No. 84971 Date: PAGENO. 7 I I L EsGil Corr>oration In Partnersfiip witfi (jovemmcnt for Buififing Safety DATE: 1/14/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-3404 SET: I1 PROJECT ADDRESS: 1903 CaUe Barcelona PROJECT NAME: Awing Over Escalator Carlsbad Forum 0 APPLICANT 0 PLAN REVIEWER 0 FILE @iE$s 0 w 0 0 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the! jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corpor’ation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contacli: person. The aplplicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steve Date contacted: /dOV (by: ) Fax #: REMARKS: I. Provide special inspectio program to the building official prior to issuance of the building permit. See attached form. 2. J rovide specification for the Sunbrella-Firesist fabric to Telephone #: (61 9)277-3539 t5C Mail Telephone - Fax In Person show the fabric is State Fire marshal approved material. Mike Peterson) will allow him hand carried the approved stated that city (Mr. city. Please verify. trnsrntl.dot By: DavidYao Enclosures: Esgil Corporation 0 GA 0 MB EJ 0 PC 118 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 . City of Carlsbad 03-3404 12/18/03 -- City of Carlsbad BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 03-3404 Job Address or Legal Description 1903 Calle Barcelona Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of thi,!; sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a cu:trent certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept ahemate materials, structural changes, or any requests for plan changes. The Special Inspector is relquired to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) City of Carlsbad 03-3404 12/ 18/03 ~PECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER’S NAME: I, as the owner, or agent of the owner (contractors may poJ employ the special inspector), certify that I, or the architecvengineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5. Signed I, as the engineerlarchitect of record, certify that I have prepared the follow@g special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. Signed I. List of work requiring special inspection: 0 0 0 Soils Compliance Prior to Foundation Inspection Structural Concrete Over 2500 PSI Hig Strength Bolting Prestressed Concrete 0 ExpansionlEpoxy Anchors Structural Masonry Sprayed-On Fireproofing Designer Specified 0 Other Field Welding 2. Name@) of individual(s) or firm@) responsible for the special inspections listed above: A. B. C. 3. A*, B. C. Duties of the special inspectors for the work listed above: EsGil Corporation In Purtnership with Governmentfor BuiUing .Yufcty WT DATE: 12/18/03 JURISDICTION: City of Carlsbad REVIEWER PLAN CHECK NO.: 03-3404 SET: I PROJECT ADDRESS: 190$ Calle Barcelona PROJECT NAME: Awing over escalator 0 FILE 5 [CazLS6Aa bk~) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. c] The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant @ The applicant's copy of the check list has been sent to: contact person. Stephen Aheberry Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Stephen Aheberry Date contacted: /L11?/Q, (by: \C- ) Telephone #: (61 9)277-3539 Fax #: (b/7)7~3,S5bL. Mail 0 REMARKS: Telephone c, Fax- In Person By: DavidYao Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 12/11 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 03-3404 121 18/03 PLAN REVIEW CORRECTION LIST COMMERCIAL r ALLOWABLE FLOOR AREA: STORIES: PLAN CHECK NO.: 03-3404 OCCUPANCY: M USE: JURISDICTION: City of Carlsbad TYPE OF CONSTRUCTION: ACTUAL AREA: S PRI N KLE RS? : REMARKS: DATE PLANS RECEIVED BY JURISDICTION: HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 1211 DATE INITIAL PLAN REVIEW PLAN REVIEWER: David Yao ll COMPLIETED: 12/ 18/03 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to 1,he issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a COPY) where each correction item has been addressed, Le., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 03-3404 12/18/03 GENERAL / 1. (1 Please make all corrections on the original tracings and submit two new complete sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (858) 560-1468. 0 PLANS 2. Provide the names, addresses and telephone numbers of the owner and the responsible desian professionals on the Title Sheet. Sec. 106.3.3. 3. All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible fo? the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. 4. Provide a statement on the Title Sheet of the plans that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 5. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? * FIELD WELDING * EXPANSION/EPOXY ANCHORS * OTHER * HIGH-STRENGTH BOLTS DESIGNER-SPECIFIED REMARKS 6. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. 0 SITE PLAN 7. Provide a fully dimensioned site plan drawn to scale. Sec. 106.3.3. Include the following: a) North arrow. b ) c) Property I in es/easem en ts . S treetda Ile ys . City of Carlsbad 03-3404 12/18/03 d) Existing and proposed buildings and structures. 8. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. 9. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan." ROOFS IO. Provide specification for the laced roof to show the lace is state firemarsher approved fire retarded material.. 0 STRUCTURAL I I. Provide complete structural details on the plans with cross referencing as needed to show the structural framing will comply with the design calculations and building code requirements. Section 106.3.3. 12. Provide minimum structural specifications on the plans to show that all structural materials will comply with the design calculations and building code requirements. 13. Provide calculations for main vertical and horizontal framing members and post footings. Section 106.3.3. 14. Provide calculations for lateral loads(wind) and show how the lateral force has been resisted? Section 106.3.1.7. 15. Provide plan to identify all the member size and connections.(which members are main frame? Is the guardrail around the escalator existing? Please clarify on the plan. X bracing size? All connections..etc) 0 ADDITIONAL 16, To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 17. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: 0 Yes 0 No City of Carlsbad 03-3404 12/ 18/03 18. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. City of Carlsbad 12/18/03 03-3404 -- City of Carlsbad BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No. 03-3404 Job Address or Legal Description 1903 Calle Barcelona Owner Address You are hereby notified that in addition to the inspection of construction provided by the Bu:i lding Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this; sheet. The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit. Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Spccial Inspectors for the type of construction for which they are certified. Thle inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not authorized to inspect and approve any work other than that for which hel’she is specifically assigned to inspect. The Special Inspector is not authorized to accept a1tl:mate materials, structural changes, or any requests for plan changes. The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that hei’she inspected and approved. The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. (over) City of Carlsbad 03-3404 121 18/03 'SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architecvengineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701 .I for the construction project located at the site listed above. UBC Section 106.3.5. Sig,ned I, a:; the engineer/architect of record, certify that I have prepared the followi~g special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. Signed 1. List of work requiring special inspection: 0 Soils Compliance Prior to Foundation Inspection Structural Concrete Over 2500 PSI 0 Prestressed Concrete Structural Masonry 0 Designer Specified 0 Other Field Welding 0 High Strength Bolting ExpansiodEpoxy Anchors c] Sprayed-On Fireproofing 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. B. C. 3. A. B. C. Duties of the special inspectors for the work listed above: . City of Carlsbad 03-3404 121 18/03 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-3404 PREPARED BY: David Yao DATE: 12/18/03 BUlLDlNlG ADDRESS: 1903 Calle Barcelona B U I L D I N G 0 C C U PAN CY: TYPE OF CONSTRUCTION: IB u I LD I NC-~~I Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. awing per city 9,960 I I I I Air Conditionina I I I I I "I I I Fire Stxinklers I I I I I TOTAL VALUE 9,960 Jurisdiction Code lcb By Ordinance I Bldq. Permit Fee by Ordinance 7 I Plan Check Fee by Ordinance 1 Type of Review: Repetitive Fee _T1 Repeats Complete Review 0 Other I $99.69 I $64.80 I 0 Structural Only Hourly I I Hour * Esgil Plan Review Fee 0 I $55.831 Comments: Sheet I of 1 macvalue.doc PLANNING/ENCINEERING APPROVALS -- RESIDEIWDAL ' TENANT IMPROVEMENT RESlDElrPTlAL ADDIT1ON MINOR PLAZA CAMlNO REAL (<$lO~emo.~~ CARLS&A;D COMPANY STORES VILLAGE FARE COMPLEeE OFFICE BUILDING PLANNER b.JwhmA- DATE 19-19-03 Carlsbad Fire Department 033404 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 6024660 Plan Review Requirements Category: Building Plan Date of Report: 01/08/2004 Reviewed by: Plan Review Requirements Category: Building Plan Date of Report: 01/08/2004 Reviewed by: Name: Stanford Sign I Address: 2556 Farre St City, State: Chula Vista CA 91 91 1 Plan Checker: - Job #: 033404 Job Name: Carlsbad Forum Bldg #: CEO33404 Job Address: '1905 Calle Barcelona Ste. or Bldg. No. Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 0 Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1st 2nd 3rd Other Agency ID FD Job # 033404 FD File # Carlsbad Fire Department 033404 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan Date of Report: 12/1712003 Reviewed by: Name: Stanford Sign Address: 2556 Farre St City, State: Chula Vista CA 91 91 1 Job #: 033404 Plan Checker: Job Name: Carlsbad Forum Bldg #: CB033404 Job Address: 1905 Calle Barcelona Ste. or Bldg. No. 0 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. 0 Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 1ncomplet:e The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1st 2nd 3rd Other Agency ID I FD Job# 033404 FD File # I. Requirements Category: Building Plan ~ ~ Requirement: Pending 05.32 Additional Requirements or Comments 1. This item shall be referred to as a canopy v. awning per CBC and CFC definition. 2. Per Article 32, Section 3207 of the CA Fire Code the canopy material shall be required to be flame retardant. The applicanffManufacturer of this canopy shall be required to submit evidence that the materials to be used are manufactured in such a way as to meet the requirements of the CA State Fire Marshal. 3. The canopy shall have a permanently affixed label indicating compliance with Article 32 or Sectior 11 03 of the CA Fire Code. Page 1 1211 7/03 manufactured 1 1-22-2003 REGISTERED ISSUED BY APptl CATION CONCERN No. IFA-36801] (phone) 336/2274211 (Fax) 336/229-4030 Glen Raven Custom Fabrics, LLC 1831 North Park Avenue Glen Raven, NC 27217 This is to cerhifL that the materials described below have hgenflanre-retaraht treated (or are inherently nonflammable). STANFORD SIGNS a AWN INC CHUU VISTA CA $l914ooOO Certification is hereby made -et: (Check "a" or "b") (3 .The d-d- Mtsate have betn~aed-yith a flame-retyiant chemical aeproved and registered by the State Fin Marshal and that the application of said chemical was done in conf'o&m dth thc laws of the State of California and the Rules and Regulations of the State Fire Marshal. Name of chemical used Chem. Reg. No. 0 Method of application (b) 'he articles dcscrii below are made from a tlame-nsistant fabric or material registered and approved by the State Fire Marshal for such use. Trade nanx of flameresistaat fabric or material used IXI 8031l60 SUNBREUA FR BURGUNDY FR 8unbd8 Reg. No. F-368.01 The Flame-Retardant Process Used WILL NOT Be Removed By Washing Glen Raven Custom Fabrics, LLC ' Name ofApplictUor w Ihduclian SupUMadcllt Control Number 74868 Order Number 84505 Invoice Number 922642 Quantity 61 .OO -* *... -. k STRUCTURAL CALCULATION The Forum at Carlsbad. 1903 CaUe Barcelona Carlsbad, ~ CA Canvas Covered Canopy L. 3 PREPARED FOR: Stanford Signs and Awning DATE: December 30,2003 Answer to Plan Check Comments. Item 3, Item 4 Item 5 Item 6 Item 10 Item 11 Item 12 Item 13 Item 14 Item 15 Plans are signed See Bases of Design note on sheet S-3 Special Inspections per sheet S- 1 Inspection program per note 2 on Sheet S-1 Sunbrella-Fireskt fabric is a fne safe material. Plans and details per sheet S-1, S-2 and S-3 Per General Notes on sheet S-3 Calculations page 1 through 21. per calculations page 4 through 21 Framing plan ,elevation, sections & details per S-1 , S-2,S-3 ., . ...., . .-, .. . , . .. . . . 1 14 . .. . , . .. ., ... . .. -. . . . . . . .. I I STRIYCTURAL ENGINEERING COAKVLTNVT SheetNo .3 of 2-l Project : Errg inedki Datc: 46.67'7 wroF K v= t . .. ! Y? - I\ ! I .. . . . . , . . ,. ,.... 3.." ,... . . . .. . .. .. . . .. , ... Basic Load, Case Data BLC No. I {asic Load Case Category Category Gravity Load Type Totals Boundarv Conditions Joint Label X Translation Y Translation Rotation Wi (Wm) (K-Wad) Reaction I Reaction 1 I R:act.:n I Reaction 1 Steel Desiqrn / NDS Parameters Member Section Length Lb out Lb in LmP Cb Sway Label Set le out le in le-bend Kout Kin CH Cm B out in Joint Coordinates Joinf Load'WEnforced DisRlacemenfs. Cateuorv : DL. BLC 1 : DL N5 N? L Y -14.6 L Y -17.7 Na N4 L Y -11.i: Joint LoauWEnforced DisRlacements, Cateuorv : LL. BLC 2 : LL Joint Libel [LJoad or Diredion Magnitude [Dlisplacement (Lb, K-ft, In, rad) L Y -12.9 L Y -48.7 L Y *71.7 L Y -71.7 L Y 48.7 NlO L Y -12.9 1 RISA-2D Version 5.1 a [WRiSAbrlsbadcanopy. no_bracefinal.r2d] Page 2 L Y -17.1 L Y -14.0 L Y -11.17 . ._,I . , ,. ~ .... 1 9 OF 21 Joint L0ad::;Enforced Displacements, Cateaorv : EM, BLC 3 : E 1 X L X L X i N 128.3 4 8 LW. I L Y 1 I I 7&2D Vr'rsion 5.la [C:VilSA\carlsbadcanopy. no-wd] Page 3 Envelope Nlfernber Section Forces, ,(continued) Member &bel Section Axial Lc Shear Lc Moment Lc Enve/ooe Member Stresses MemberLsbel Section Axial Shear Bending top Bending bot I_ RISA-2D t’ ., L . .. .. .. .. - Envelope Member Stresses, (continued) Member Label Section Axial Shear Bending top Bending bot I RISA-20 Version 5.la [C\RISA\carlsbddcanopy. no-brawfinal.Rd] Page 5 ~ ) ---.-v /, Envelolbe Memb ASD 9th Code Checks MemberLabel Codehk Loc ShearChk Lac Fa Ft Fb AS0 Ean. i . ..' .. , 2 0.191 A 0 2 i LEa REA-2D Vsrsion 5. la [C:WlSAkarlsbadcanopy. no-bracefinal.fld] Page 7 0.002 0 2 14.097 21.6 23.76 HI-2 0 0 1 21.194 21.6 23.76 H2-I 0.037 0 2 20.758 21.6 23.76 HI-2 * Po Lo Y c- a Basic Load Case Data BLC No. Ilasic Load Case Category Category Gravity Load Type Totals Boundan, (:onditions Joint Label X Translation Y Translation Rotation Win (Win) (K-fthd) Reaction I Reaction I Joint Coorciinafes Joint Label X Coordinate Y Coordinate Joint Temperature 3 N9 NlCl E L Y -11.17 L Y -14.8 L Y -17.14 L Y -17.14 L Y -14.8 t Y -11.t7 L Y L Y L Y ' E---? N10 L Y L Y Joint hkl llload or Direction Magnitude -48.7 -71.7 -71r7 -12.9 -48.7 N17 Joint Load,s/Enforced Displacements. Cafeuorv : wu(. BLC 4 : W horiz L X 128.3 L X 28.1 L X I 28.1 L Joint LoadsEnforced Displacements, Catesorv : WL+Y. BLC 5 : W uvlift Y 58 1 Joint La bel lLload or Direction Mapnitude t L Y 581 Envelope Reactions Joint Label X Force Moment Envelope Member Section &mes MemberLabel Section Axial Lc Shear Lc Moment Lc i .- h Id Oy-2-t Envelope Member Section Forces, [continued) Member Label Section Axial Lc Shear Lc Moment Lc racedcanopy. final.Rd .. .. .. .. I- ., .. \q.QFz\ Envelope filember Section Forces, (continued) Member Label Section Axial Lc Shear Lc Moment Lc ” Envekme Allember Stresses Memberlabel Section Mal Shear Bendina too Bendina bot Member D4,sta Section End Releases Endoffsets Inactive Member Member Lahel I Joint J Joint Rotate Set I-End J-End I-End J-End Code Lenath OF Mtkbeipi fa (continued) Section End Releases End Offsets Inactive Member Member Lab ?I I Joint J Joint Rotate Set I-End J-End I-End J-End Code Length M20 Enveloue Member AISC ASD 9th Code Checks MemberLabel CodeChk Loc ShearChk Loc Fa Ft Fb AS0 Ean. + RISA-2D Version 5,la [C:WlSAkarlsbadbracedcanopy. final.Rd] Page 7 . .. .. . .