Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; 214; CB041656; PermitJob Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 Commercial/lndustriaI Permit Permit No: (26041 656 1905 CALLE BARCELONA CBAD St: 214 TI Sub Type: COMM Lot#: 0 Status: ISSUED $53,580.00 Construction Type: NEW Applied: 05/12/2004 REJ EUVl NE Plan Approved: 07/02/2004 1,786 SF SHELL TO RETAIL Issued: 07/02/2004 Reference #: Entered By: MDP Inspect Area: Plan Check#: Owner: SI MACCONSTRUCTION I NC 15938 BERMUDA CENTER DR SD 921 27-1828 858-674-9880 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee $369.46 $0.00 $240.15 $0.00 $0.00 $1 1.25 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Red. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $975.16 $0.00 $0.00 $0.00 $0.00 $0.00 $83.00 $1 10.00 $39.50 $0.00 $0.00 $0.00 $0.00 $1,828.52 Total Fees: $1,828.52 Total Payments To Date: $240.15 Balance Due: $1,588.37 5793 07/02/04 0902 01 CGP 02 1588 * 37 FINAL APPROVAL Inspector: Date: 9 r'9, ocf Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exadons hereafter collectively referred to as "feesiexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. 6-z 5 2 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. &- \&G 3, \*o Plan Ck. Deposit "r y a. ti Date - c\ \LI k Validated By I Name Address City Statelzip Telephone # issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code1 or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001). S/Mi% c ONS7L2t/C7/Dd 3m 7 U/N& &a$€ 13 L sz *A"&q&&W (3A - 737- nix? Name Address city StatelZ: State License # 4tJGOSB Designer Name Address city ' Statelzip Telephone License Class ' City Business License # ?zh% # PdM IAJ7U IOM~ 27 r .(;&&g*i4d ALVD RPVkdLY #/& J c9 909/? G2- 7606 Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 of the work for which this permit is issued. 0 issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars l$100,000L in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. 4. number I contractors license number): 5. of work): I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type Business and Professions Code for this reason: PROPERTY OWNER SIGNATURE DATE IN$ PER Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 0 YES 0 NO DING AGENCY is a construction len LENDER'S NAME LENDER'S ADDRESS CERTl e read City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the authorized by such permit is not commen at any time after the work is commenced APPLICANT'S SIGNATURE DATE itation and become null and void if the building or work e date of such permit or if the building or work authorized by such permit is suspended or abandoned ection 106 4.4 Uniform Building Code). city Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite %- Plan Check #: Permit #: CB041656 Project Name: REJEUVINE Address: 1905 CALLE BARCELONA #214 Lot: Contact Person: ROSS Phone: 8585832787 Sewer Dist: LC Water Dist: 0 1,786 SF SHELL TO RETAIL Date: Permit Type: Sub Type: 0 09/01/2004 TI COMM .......................................................................................................................................................... By: Inspected d- k$aL-) E;ected: s/ 33 /$t Approved: disapproved: Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Comments: ........................................................................................................................................................... City of Carlsbad Bldg Inspection Request For: 09/08/2004 Permit# CB041656 Inspector Assignment: PS Title: REJEUVINE Description: 1,786 SF SHELL TO RETAIL Type: TI Sub Type: COMM Job Address: 1905 CALLE BARCELONA Suite: 21 4 Lot 0 Location: APPLICANT SIMACCONSTRUCTION INC Owner: Remarks: Total Time: CD Description 19 Final Structural Phone: 8585832787 Inspector: 43 Requested By: ROSS Entered By: CHRISTINE * 29 Final Plumbing 39 Final Electrical t 49 Final Mechanical Associated PCRs/CVs Inspection History Date Description Act lnsp Comments 09/03/2004 89 Final Combo co PS 09/01/2004 89 Final Combo CA PS RESETTOTHURS 08/24/2004 84 Rough Combo AP PS T-BAR 08/23/2004 84 Rough Combo CO PS ONT-BAR 0811 1/2004 17 Interior Lath/Dtywall AP PS 0811 0/2004 17 Interior Lath/Drywall CA PS BYROSS 08/09/2004 84 Rough Combo PA PS CKBRACINGLATER 08/06/2004 14 Frarne/Steel/Bolting/Welding WC PK 08/06/2004 17 Interior LatWDrywall PA PK WALLSONLY 08/03/2004 14 Frame/Steel/Bolting/Welding AP PY 08/03/2004 21 Underground/Under Floor AP PY 08/03/2004 24 RougNTopout AP PY 08/03/2004 34 Rough Electric AP PY 07/27/2004 TUE 11:21 FAX +++ MTGL-ANAHEIM @l002/005 Corporate: San Diego/lmperisl County: 2992 E. La Palrna Ave., Suite A Anaheim, CA 92806 731 3 Carroll Road, Suite G San Diego, CA 921 21 Tel: 71 4.632.2999 Fax. 71 4.632 2974 Tel: 858.537.3999 Fax: 858.537.3990 Inland Empire: 14320 Elswotth Stwet, Suite Ctol Moreno Valley. GA 92553 Te[: 909.653.4999 Fax: 909.653.4666 FIELD REPORT I LUNCH PERIOD; TRAVEL TIME; VERIFIED BY: E@&&& I I DO CERTIFYTHAT I HAVE PERSONALLY OBSERVED ALL OF THE WORK LISTED ABOVE AND THAT THIS WORK COMPLIES WITH THE SOIL INVESTIGATION RECOMMENDATIONS. 4ND /OR THE APPROVED PLANS, SPEClFlCATlQNS AND APPLICABLE SECTION OF THE BUILDING CODE, UNLESS OTHERWISE NOTED IN THE DEFiCIEkCV REPORT Print Name EsGil - Corporation In Partnership with Government for Quiliiing Safety 0, PP ICANT R& 0 PLAN REVIEWER Q FILE DATE: 6/30/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1656 SET: I11 PROJECT ADDRESS: 1905 Calle Barcelona Suite 214 PROJECT NAME: Rejeuvine Medspa - TI w 0 0 w w The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 REMARKS: Applicant to provide completed Mail Telephone Fax In Person form to City for Field Welding. / By: Doug Moody Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 6/16/04 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for BuiGfing safety DATE: 6/ 16/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1656 0 PLAN REVIEWER 0 FILE SET: I1 PROJECT ADDRESS: 1905 Calle Barcelona Suite 214 PROJECT NAME: Rejeuvine Medspa - TI 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant w The applicant’s copy of the check list has been sent to: contact person. Simac Construction / John Sullivan 2067 Wineridge Place Suite A, Escondido, CA 92024 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: John Sullivan Date contacted: &/I ?/or (by: 6.) Telephone #: 760-737-21 00 Fax #: 760-737-21 10 Mail Jelephone Fax/ In Person 0 REMARKS: By: Doug Moody Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ PC 611 0/04 tmsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 04-1656 61 1-6/04 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1656 PROJECT ADDRESS: 1905 Calle Barcelona Suite 214 SET: rr DATE PLAN RECEIVED BY ESGIL CORPORATION: 6/10/04 H I DATE RECHECK COMPLETED: 6/ 16/04 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, I997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit three new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo City of Carlsbad 04-1656 6/ 16/04 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustria1 projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 5. Please note on the plans “AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits”. Not indicated on the plans. 6. Please provide the mounting and structural attachment of the new 30 KVA transformer in the ceiling. Please clarify the plan the resubmitted plans did not show the location of the electrical panels. Please show the location and the required working clearance. 13. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 635# rooftop air handler unit. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. The provided structural plans indicate new structural member to be welded to the existing frame. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM * FIELD WELDING REQUIRED? REMARKS City of Carlsbad 04-1656 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. * 6/16/04 . 14. Please provide a platform detail for the mounting of the 40 gallon water heater above the restroom ceiling. Please revise the plans to show a platform adequate to support the 400# water heater. 15. Please revise the discharge location of the T&P for the waster heater the indirect waste receptor may not be enclosed with in the cabinet per section 804.1 of the UPC. The plans still show an indirect waster receptor in the cabinet. Please revise the discharge location. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Cailsbad 64-1656 6/30/04 BUILDING DEPARTMENT -MENT FOR SPECIAL INSPECTION Da Not Remove Fkom Plans Plan clseck NO. 04-1656 Job Address or Legal Description 1905 Cue Bwcdooa Suite 214 You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet. The Regiartered Special ln~pe~tor &dl be approved by the City of Carlsbad Building Department prior to the issuance of the building pennit. Special Inspectorn having a cmt certification from the City of $an Diego, Los Angeles, or ICBO are approved as Special Xnspectore for the type of construction for which they are cdfied. The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department. The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code. The Special Inspector is not authorized to inspect and approve any work other than that for which hdshe is specifically assigned to inspect. The Special Inspector is not authorized to accept alternate materials, structural changes, or any quests for plan changes. The Special Znqector is required to submit Written reports to the City of Carlsbad building department of all work that hdshe inspected and approved. The final inspection approval will not be given until all Special Inppection reports have been received and approved by the City of Carlsbad building department. Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet. ZO'd t€:6 POOZ I 'dt103 119S3 . Cityof-lsbad 04-1656 6/30/04 SPECIAL INSPECTION PROGRAM PLAN CHECK NUMBER: 04-1656 OWNER’S NAME: eA-m.ANw me. ~~ “REJ&dVUu C’’ I, as the owner, or agent of the owner (contractors may cefliw that I, or the architectlenginesr of record, will be responsible for employing the special required by Uniform Building Code (UBC) Section 1701.1 for the construction employ the special inspector), the sit) lismove. UBC Section 106.3.5. I, as the engineer/arohiteot of roaord, cdfy that I have prepad &e following qyspacial inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. A 1. List of work requlrlng speclal Inspection: c] Soils Compliance Prior to Foundation Inspection 0 structural Concrete mer 2500 PSI 0 Prestressed Concrete structural Masonry Tz] Deslgner Specified 0 Other ~Fleld%%lding 0 Hlgh Strength Bolting 0 ExpansionlEpoxy Anchors 0 Sprayedan Flreprooflng 2. Name(@ of IndlvldUal(S) or flrm(8) responsible for the special inspections llsted above: A s. C. 3. k 8. C, Duties of the special inspectors for the work listed above: CJ cl&w AiU nw PEL957 €0 ‘d ZE:6 POOZ I IT ’dt103 119’3 Pleas6 make all corrections on the orlginal traclngs, as requested in the correction list. Submit three sets of plans for c~mrne~xial/industrlal pmjects (two sets of plans for residential projeds). For expedttloue pmcesslng, corrected sets can be submitted in one of two ways: 1, Deliver all corrected sets of plans and calculationslrepoh directly to the Clty of Cedsbad Building Department, 1635 Faraday Ave., Cerlsbad, CA 92008, (760) 602-2700. The City wlll mute the plans to EsGit Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one cortsated set of plans and calculationdreports to EsGil Corporation, 0320 Chesapeake Drive, Sub 208, San Diego, CA 92123, (858) 560-1466. Deliver all remaining sets of plans and calculations/rep,orts directly io the City of Carlsbad Building Department for muting to their Planning, Engineering and Fire DmIrtmenb. NOTE: Plans that are submitted directly to EsGil Corporation only wlll not be reviewed by the Clty Planning, Engineering and Fire Departments until review by EsGil Corporation Is complete. Provlde a section view of all new interior partltions. Show: e) b) c) d) SE?L qsc 4-9.0 S SKVOt\l3/Aa-O I. Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended cellhg has been designed for partition k&ml load). Wall sheathing material and details of attachment (aize and spacing of fasteners). Show helght of partition and suspended ceiling, end height from floor to roof framlng or floor framing. ,- Provide 8 section vlew of the new sofflts in the receptlon, Show: a) Type, size and spaclng of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or Indicate "to be ICE30 approved", b) Method of attaching top to the structure and lateral bracing. c) Wall sheathing material and details of attslchrnent (slza and spacing of fasteners). d) Show height of the soffit from floor, soffit to roof framing or floor framing. In Groups 8, F, HI M and S Occupancies, if the number of employees exceeds four, provide separate toilet facilities for men and women, If "the total number of employees will not exceed four", and only one restroom is provided, note the words In quotation above on the floor plan, Section 2902.3. I. Please clarify the door schedule to show door 6. Please note on the plans "AC Cablo i; rist allowed in A, 8, E, H, and I occupancies. NM cable is restrictad (without City approval) to one and two family dwellings. Note on plans that an equipment ground conduCtOr is to be installed in all flexible conduits". PO'd 95:PT PoOt LZ fW4 9LST09S8SN : 'dt103 1I9S3 50 35" as ~WIS BT'EZLEL09L ZP :P0 P002/0Z/50 " ? s=- ) f ( 8, €3.0 s€€ 11. .- Please mrred the LTG forms to show the correct square footage. Please clarify panel schedule HA to show the over-current device and load from panelLA. . Please revise the main over-current device in petngl LA to be limited to 125% of the transformer secondary. -- Please provlde the mounting and structural attachment of the new 30 KVA transformer in the celling. 1 # Please revise the plans to show the tsstroom to be equipped wlth an envlronmental air exhaust fan shed to provide a minimum of 4 alr changes per hour. Section 1202,2.2.1 of the UBC. Please imprint on the plans the City of Cerlsbad Pollclea and Proceduree for Roof Mounted Equipment to the plans. The completed and signed MECH-1 forms must be imprinted on the plans. Please provide plans and aelculations signed by the California State licensed engineer or architect for the structural support of the 635## rooftop air handler unit. Include all calculations and finding on the plans. Please include the Califomla license number, seal, date of license expiration and date plans are signed. Business and Professlons Code. Please provide a platform detail for the mounting of the 40 gallan water heater above the restroom ceiling, Please revise the discharge location of the TBP for the waster heater the indirect waste receptor may not be enclosed with in the cabinet per section 804.1 of'the UPC. Please revbe the plans to show a disabbd accessible transection Counter located at Q section of counter that is at least 36" long and no more than 28" to 34" high, Section 1 1228.4. 1 Show that grab bars comply wlh the following, per Section 1 1158.8: a) They shall be securely attached 33" above the floor, and parallel, NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33". the rear grab bar only may be installed as hlgh 86 36". To speed up the review process, note on this list (or e copy) where each correction hem has been addressed, Le., plan sheet, note or detall number, calculatlon page, etc. .. * I Y of Cubbad' 0446S6 17/04 Please indicate here if any changes have been made to the plans that are not a n~lt of corrections from this list. If there are other changes, please briefly describe them and where they are located In the plans. haveghenges been made to the plans not resulting from this correction list? qieaae indicate: Yes EQ -No c1 -- .. The jurisdidion has contracted with Esgil Corporation louated at 9320 # Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 85W560-1488, to perform the plan dew for your project. If you havg any questions regarding these plan review Items, please contact Doug Moody at Esgil Corporation. Thank you. i -- - -- .. IPMENT kND an Integrd roved, it shall uste. ihdl be lnsida nant shall be pproval from 1 hzve one o back or in snd use the ; to back or In - EsGil - Corporation In (Partncrsfiip witfi tjovernment for QuiHing Safety DATE: 5/27/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1656 0 PLANREVIEWER 0 FILE SET: I PROJECT ADDRESS: 1905 Calle Barcelona Suite 214 PROJECT NAME: Rejeuvine Medspa - TI 0 The plans transmitted herewith have been corrected where necessary and substantially comply The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list with the jurisdiction’s building codes. and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Simac Construction /John Sullivan 2067 Wineridge Place Suite A, Escondido, CA 92024 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: John Sullivan (q, r/l) Date contacted: 5 /t 3/09 (by: p- ) Telephone #: 760-737-21 00 Fax #: 760-737-21 10 Mail “elephone --- Fax In Person 0 REMARKS: By: Doug Moody Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ PC 5/13/04 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 SanDiego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 c City of Carlsbad 04-1656 5/27/04 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS OCCUPANCY: B USE: Spa TYPE OF CONSTRUCTION: VN ACTUAL AREA: 1786sf ALLOWABLE FLOOR AREA: STORIES: 2 HEIGHT: SPRINKLERS?: YES OCCUPANT LOAD: 17 DATE PLANS RECEIVED BY JURISDICTION: 5/12/04 A DATE PLANS RECEIVED BY ESGIL CORPORATION: 511 3/04 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Doug Moody I COMPLETED: 5/27/04 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change, All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked UP list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforu.dot City of Carlsbad 04-1656 .5/27/04 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustria1 projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1, Deliver all corrected sets of plans and calculationsheports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculationslreports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculationslreports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a section view of all new interior partitions. Show: a) b) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). Wall sheathing material and details of attachment (size and spacing of fasteners). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. c) d) 2. Provide a section view of the new soffits in the reception. Show: a) b) c) d) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top to the structure and lateral bracing. Wall sheathing material and details of attachment (size and spacing of fasteners). Show height of the soffit from floor, soffit to roof framing or floor framing. 3. In Groups B, F, H, M and S Occupancies, if the number of employees exceeds four, provide separate toilet facilities for men and women. If "the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 2902.3. 4. Please clarify the door schedule to show door 6. 5. Please note on the plans "AC Cable is not allowed in A, B, E, HI and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". City of Carlsbad 04-1656 . 5/27/04 6. 7. 8. 9. IO. 11. 12. 13. 14. 15. 16. 17. Please correct the LTG forms to show the correct square footage. Please clarify panel schedule HA to show the over-current device and load from panel LA. Please revise the main over-current device in panel LA to be limited to 125% of the transformer secondary. Please provide the mounting and structural attachment of the new 30 KVA transformer in the ceiling. Please revise the plans to show the restroom to be equipped with an environmental air exhaust fan sized to provide a minimum of 4 air changes per hour. Section 1202.2.2.1 of the UBC. Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. The completed and signed MECH-1 forms must be imprinted on the plans. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 635# rooftop air handler unit. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Please provide a platform detail for the mounting of the 40 gallon water heater above the restroom ceiling. Please revise the discharge location of the T&P for the waster heater the indirect waste receptor may not be enclosed with in the cabinet per section 804.1 of the UPC. Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36" long and no more than 28" to 34" high. Section I 1228.4. Show that grab bars comply with the following, per Section I1 15B.8: a) NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. They shall be securely attached 33" above the floor, and parallel. bar at 33", the rear grab bar only may be installed as high as 36". City of Carlsbad 04-1656 5/27/04 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. CITY OF CARLSGAD POLlCIES AND PROCEDURE ' !UMBER: 80-6 I SUBJECT: ROOF MOUNTED EQUIPMENT - EFFECTIVE: 5/1/92 SECTION: BULLDIN G 0 EPARTM ENT \ SUPERSEDES: 80-6(9/1 OlSO) 1 . 80-6(5/01/81) - PURPOSE: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED E@UIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. INTENT: A. 8. C. POLICY: 1. 2. 3. 4. 5. - '6. .. . 7. Maintain roof integrity. Preveni'hazardous condition io firemen who must fighi fire on ;he roaf. Provide an installation that is aesthetically sensitive to the building and ?he adjoining properties: . a All equipment shall be conceded from view and the design* sh~ll mest ;he . . approval of. the Planning Department. All equipment shall bs specificqlly designed and approved for exterior use 2nd shall be approved by the City of Carisbad Building Department. All roof mounted equipmen: shall be on i! platform which shall be En integr2.l part of the roof-flashsd and wsterproofed. Wnen a screen is'app;ovsd, it shall have as few roof connections 2s possible and be structurally adequEte. All electrical, plumbing, mechsnical duct work and related piping shzll be inside the building'and not on ;he roof. All connections related to equipment shall be made in the same roof opening on the platform or have the prior Epprovsl from the building official. Sewer vents shall be brouqht to one main vent below the roof 2nd have one penetration where restrooms or other plumbing fixtures ijre back to back or in the general proximity, Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms 2nd other equipment are back to back or in general proximity. Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior.approval from the buiiding official. .Where new equipment is installed; unused'or abandoned equipment, including . all roof mounted piping, electrical, mechanical, duct, and other' r'elated appurtenances shall be removed from roof and unused openings p.roperly sealed .to maintain roof integrity. .. e. The architect should, through de'sign, cancezl the heating/AC unit and other equipment whethet * they are on the roof or elsewhere. . B rnitiated By: Approved 8 City of Carlsbad 04-1656 5/27/04 PALUATION AND PLAN CHECK FEE Air Conditioning Fire Sprinklers TOTAL VALUE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody 53,580 PLAN CHECK NO.: 04-1656 DATE: 5/27/04 BUILDING ADDRESS: 1905 Calle Barcelona Suite 214 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN Jurisdiction Code Icb By Ordinance 1994 UBC Building Permit Fee I V 1 1994 UBC Plan Check Fee w Type of Review: Complete Review 0 Structural Only 0 Repetitive Fee 71 Repeats I 0 Other Hourly -1 Hour * Esgil Plan Review Fee 0 I $360.46 1 $234.301 I $201.861 Comments: Sheet1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMJT NUMBER CB I(@%' DATE RESIDENTIAL RESlDENTIAL ADDmON MINOR (< $10,aao.00~ CARLSBAD COMPANY STORES VILLAGE FAlRE C0M-E OFFICE BUILDING OTHER PLANNER DATE 9 - 19 -04 c- - ENGINEER. DATE 4 " Carlsbad Fire Department 041 656 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan A# Date of Report: 05/78/2004 Reviewed by: Name: John Sullivan Address: 2067 Wineridge PI City, State: Escondido CA 92024 Job#: 041656 Plan Checker: Job Name: Rejeuvine Blda #: CB041656 Job Address: 1905 Calle Barcelona Ste. or Bldg. No. 214 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. IXI c] Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. c] Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2 nd 3 rd Other Agency ID FD Job # 041656 FD File # - Carlsbad Fire Department 041656 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 An Plan Review Requirements Category: Building Plan Date of Report: 05/17/2004 Reviewed by: bG& Name: Nadel Architects Address: City, State: 5465 Morehouse Drive Suite 165 San Diego CA 92121 Job #: 041656 Plan Checker: Job Name: Rejeuvine Bldg #: CB041656 Job Address: 1905 Calle Barcelona Ste. or Bldg. No. 214 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 0 Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2nd 3rd Other Agency ID FD Job # 041656 FD File # 04 1 656 . Carlsbad Fire Department 1635 Faraday Ave. Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report: 05/17/2004 Reviewed by: Name: Nadel Architects Address: 5465 Morehouse Drive Suite 165 City, State: San Diego CA 92121 Plan Checker: Job Name: Rejeuvine 041 656 Job Address: 1905 Calle Barcelona Ste. or Bldg. No. 214 Carlsbad Fire Department require that all business occupancies provide this agency with a key to the main access door only if the owners hardware has been changed at or prior to final inspection. , Requirements Category: Building Plan ~ Requirement: Pending 05.22 Exit Door Hardware 9. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exception: In group B occupancies, key locking hardware may be used on the Main Exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or adjacent to the door stating, "This door to remain unlocked during business hours." For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is occupied." See item 32 for additional exit door hardware requirements. Thumb-turm locks are not permitted for use in occupied businesses. CFD requires that double cylinder (keyed) deadbolts be installed. Page I 0511 7/04 0 I. I *. .. ' A R c H --I N T E..R I o R s - oaigrii G~OU~, Inc. , I -. 1 _.- 7 .-_ 275 South Rob&? Boulevard I Beverly Hdk, C4 9021 I llX 310 652-7600 FAX310 652-7602 www.an%interwrs.com /. -, P John Sullivan ,- SIMAC CONSTRUCTION INC. 2067 Wineridge Place, Suite A Escondido, CA 92029 / VIA MAIL . ! , r - -8 June 8,2004 - PROJECT 345 - REJEUVINE MED SPA , PLAN CHANGE - DELTA 2 \ '3 AFLCe\T&CdUL SHEET A-0.2 i I. Revised contractors information. Y I. 2. Added note. . 3. Revised sheet index. 4. Revised code analysis. ' SHEET A-2.0 1 1. Revised doors @ storage 1 12 2. Added key note and dimension to niche. 3. ' Revised storefront door and add6d door number @ room 108. 4. Revised key notes. c 'L * 5 5. Revised wall types legend. - .- 6. Added section cuts and call-outs. __ . ' -. - SHEET A-2.3 -- . * , 1. * Added supplies-and returns to R.C. 2,. Added note 5 to HVAC notes. %' 3. Revised ceiling @ restroom. P. i c ‘7 MESM ENGINEERIING INC. 1 STRUCTURAL CONSULTING 2 180 GARNET AVE., SUITE 2E SAN DIEGO, CALIFORNIA 921 09 [PI 858 273 8701, IF] 858 273 6758 email: mikemesri@aol.com ADDITION OF THE TWO 520 POUND EQUIPMENT FOR THE REJEWINE T.I. AT THE FORUM AT CARLSBAD BLDG 1 DATE: June 8,2004 CLIENT: SIMAC CONSTRUCTION -- - ........ _---_ -. - ... ___- .......... .. -. - - . - . ......... ...... - ..... .. ............... ,,/lI IO,, , , ........ .. ...... ..... - . ......... -. - .. ..... -.., .__. ............ .. To specify your title block on Title : Job # Dsgnr: Date: 1:53PM, 8 JUN 04 Description : Scope : these five lines, use the SETTINGS . selection on the main menu and enter your title block information will be printed on each page. --_ Rev 506001 Single Span Beam Analysis I Description FORUM AT CARLSBAD - ' General Information I ~~ ~ ~~~ ~~ ~ ___ Center Span 44.00 n Moment of Inertia 510.000 in4 Left Cantilever ft Elastic Modulus 29,000 ksi Right Cantilever ft Beam End Fixity Pin-Pin -. . Uniform Loads I I On Center Span ... On Left Cantilever ... On Right Cantilever ... #1 0.290 wn #1 klft #1 wn __ .~ . Point Loads I Magnitude 0.130 k 0.130 k Location 13.000 ft 38.000 ft k ft k n k n Query Values I Center Location 0.000 n Left Cant 0.000 ft Right Cant 0.000 ft Moment 0.00 k-n 0.00 k-n 0.00 k-n Shear 6.49 k 0.00 k 0.00 k Deflection 0.00000 in 0.00000 in 0.00000 in ~ Moments ... Shears ... Reactions ... ~ Max + @ Center 71.42 k-ft at 21.96 ft @ Len 6.49 k @ Left 6.49 k 1 6.53 k @ Right 6.53 k I Max - @ Center 0.00 k-ft at 44.00 ft @ Right Maxim u m 6.53 k @ Len Cant 0.00 k-ft @ Right Cant 0.00 k-ft Deflections ... @ Center -1.685 in at 21.96ft @ Left Cant. 0.000 in at 0.00 ft @ Right Cant 0.000 in at 0.00 ft Maximum = 71.42 k-ft (c) 1983-98 ENERCALC KW-0603482, Ver 5.0.6, 15-Jul-1998. Win32 r la-. ,-7 .... i.i ---- L I 44.w ll 0 0 Mrnax= 71.41 k-hat21.95khomleh Omax = -1.6854 in at 2 1.95 h from leh RI = 6.489 k Vrnax @ leh = 6.489 k Rr = 6.556 k Vmaa @ n = 0.530 k . .. -t- 3 JI 1 .- L u 4 4 . -=k 3 J r \\ L) -. 3 I 5