Loading...
HomeMy WebLinkAbout1905 CALLE BARCELONA; 226; CB052624; Permit01-13-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB052624 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1905 CALLE BARCELONA CBAD St: 226 Tl Sub Type: 2550120400 Lot#: $252,619.00 Construction Type: Reference #: MERINO DESIGN 8149 SF FROM OFFICE TO OFICE/SHOWROOM COMM 0 VN Applicant: STEVEN KOHN STE4 2168 BALBOA AV 92109 858-274-1812 Status: ISSUED Applied: 07/15/2005 Entered By: KG Plan Approved: 01/13/2006 Issued: 01/13/2006 Inspect Area: Plan Check*; Owner: BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L C/ BORDERS INC 300 VILLAGE GREEN CIR SE #200 SMYRNA GA 30080 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $1,017.80 $0.00 $661.57 $0.00 $0.00 $53.05 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0,00 $34.00 $60.00 $24.00 $0.00 $0.00 $0.00 $0.00 $1,850.42 Total Fees:$1,850.42 Total Payments To Date:$1,850.42 Balance Due:$0.00 BUILDING PLANS ^— IN STORAGE ATTACHED Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE flat approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32,030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise exoired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 FOR OFFICE USE ONLY PLAN CHECK EST VA Address (include Bldg/Suite #)Business Name (at this address) Legal Description Ot Lot No. Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use (Sec. 7031.5 Business and Professions Code; Any City or County which requires a permit to construct, after, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending wilh Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). Name State License# C3??9O Address License Class City State/Zip City Business License Designer Name State License # _ Address City State/Zip Telephone # Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declaralions: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company ^J^Tf ftftJQ Policy No._/j3L?_j^.?_?J? Expiration Date _<jjfL" jO 1 "3 ° Q j" (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify thai in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($100,000), in^djdltion to fhe cos£o{/onjp6^alion, damages are provided for in Section 3706 of the Labor Code, Interest and attorney's fees. I hereby affirm that I am exempt from the Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O !, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontraclors license number): __: ^ 5. I will provide some of the work, bull have contracted (hired) the following persons to provide the work indicated (include name/address/phone number/type of work): PROPERTY OWNER SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES B^NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES BT^NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097{l) Civil Code). LENDER'S NAME . LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that Ihe information on the plans is accurate, I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of Ihe City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations of 5*0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of ^Sp days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance CRytlGirtsftU Final Building Inspection Dept: Building Engineering Plan Check #: Permit #: Project Name: Address: Contact Person: Sewer Dist: Inspected Bv: Inspected Bv: Inspected Bv: Planning CMWD CB052624 MERINO DESIGN 8149 SF FROM OFFICE TO OFICE/SHOWROOM 1905 CALLE BARCELONA #226 STEVE LC x5J?—1 Phone: 6193165552 Water Dist: O Date , . Inspected: /'/ "^ [£< Date Inspected: Date Inspected: StLite tog Date: Permit Type: Sub Type: Lot: 0 * Aooroved: ^ Aooroved: Approved: 11/03/2006 Tl COMM Disaooroved: Disapproved: Disapproved: Comments: City of Carlsbad Bldg Inspection Request For: 11/03/2006 Permit* CB052624 Title: MERINO DESIGN 8149 SF FROM Description: OFFICE TO OF ICE/SHOWROOM Inspector Assignment: PY Type:TI Sub Type: COMM Job Address: 1905 CALLE BARCELONA Suite: 226 Lot 0 Location: Inspector: OWNER BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L Owner: Phone: 6193165552 Remarksf Total Time:Requested By: STEVE Entered By: CHRISTINE CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# PCR06016 ISSUED MERINO HOMES INTERIOR COSMETIC; CHANGES Inspection History Date Description Act 07/11/2006 17 Interior Lath/Drywall AP 06/21/2006 84 Rough Combo AP 06/15/2006 84 Rough Combo NR 04/12/2006 14 Frame/Steel/Bolting/Welding PA 04/12/2006 24 Rough^Topout AP 04/12/2006 32 Const. Service/Agricultural WC PY 04/12/2006 34 Rough Electric AP PY EMR#226 04/12/2006 44 Rough/Ducts/Dampers NR PY Insp Comments PY PY CEILING OK TO COVER PY NO ONE THERE DOOR LOCKED PY WALLS PY EsGil Corporation In {Partnership vritft (jovtmmtnt for <BuiCding Safety DATE: 8/24/05 Q AEEUCANT JURISDICTION: Carlsbad O PLAN REVIEWER a FILE PLAN CHECK NO.: 052624 SET: II PROJECT ADDRESS: 1905 Calle Barcellona. Suite 220 PROJECT NAME: Merino Home Furnishing Retail Store TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LJ The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 8/16/05 tmsmtf.dot EsGil Corporation In 3?artntTsfiip witk government for 'BuiCding Safety DATE: 7/29/05 a APPLICANT a(JURJSl> JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 052624 SET: I PROJECT ADDRESS: 1905 Calle Barcellona, Suite 220 PROJECT NAME: Merino Home Furnishing Retail Store TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Kohn Architecture 2168 Balboa Ave., Suite 4, San Diego, CA 92109 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Kohn Telephone #: (858) 274-1812 Date contacted:! W 'o$~"(by: fa*) Fax #: (858) 274-1433 Mail-^ Telephone Fax-/ In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 7/19/05 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad 052624 7/29/05 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 052624 JURISDICTION: Carlsbad OCCUPANCY: M USE: retail store TYPE OF CONSTRUCTION: VN ACTUAL AREA: 8149 TI Only ALLOWABLE FLOOR AREA: no change STORIES: no change HEIGHT: no change SPRINKLERS?: Yes OCCUPANT LOAD: 120 REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 7/19/05 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Chuck Mendenhall COMPLETED: 7/29/05 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You ma/have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tifow.dot Carlsbad 052624 7/29/05 • Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. The design architect of record must sign special note #1 on sheet T1 indicating compliance with the current disabled access standards. Otherwise provide complete details and notes on the plans for all access requirements. 3. The plans submitted to the city do not contain sheet A4. this sheet is listed in the Sheet Index on T1 as interior elevations. Incorporate this sheet into the plans. 4. Include as part of the plans details for the Hard lid ceiling construction and details for the construction of the coffered ceilings. See sectfon 1/A3 referencing detail 5/A2. There is no detail 5/A2. 5. Show in detail 12/A6 that the checkout counter heath is 28" to 34" high to accommodate the disabled. 6. Why don't AC units AC4 & AC1 shown on sheet MP-2 have duct smoke detectors? The air within these units circulates with the other units that do have duct smoke detectors. Provide smoke detection in the supply air duct of an "air- moving system" for required shut-off of equipment for smoke control. UMC Section 609.2. An "air-moving system" is a system designed to provide heating, cooling, or ventilation in which one or more air-handling units are used to supply air to a common space or to draw air from a common plenum or space. UMC Section 203.0. END OF REVIEW Carlsbad 052624 7/29/05 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 052624 7/29/05 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 052624 PREPARED BY: Chuck MendenhaU DATE: 7/29/05 BUILDING ADDRESS: 1905 Calle Barcellona, Suite 220 BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN BUILDING PORTION Store Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 8149 cb Valuation Multiplier City Est By Ordinance Reg. Mod. VALUE ($) 252,619 252,619 $1,017.80 Plan Check Fee by Ordinance Type of Review: I I Repetitive FeeRepeats Complete Review D Other ,—I Hourly Structural Only Hour Esgll Plan Review Fee $661.57 $569.97 Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) ^^^TENANT IMPROVEMENT — S PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER Y DATE OQCl/MMnf nuMMtutinn tnoini^na Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 08-19-2005 Reviewed by: Name: Address: STEVEN KOHN STE4 2168 BALBOA AV SAN DIEGO CA 92109 Permit #: CB052624 Job Name: MERINO DESIGN 8149 SF FROM Job Address: 1905 CALLE BARCELONA CBAD St: 226 udiuuuiuli rfB* PI i M •*fj-"**" •fen* idi'ui uuuidmdu. Pli d******tu UiU uffliL flu iLii Conditions: id u Cond: CON0000658 APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 08/19/2005 By: gr Action: AP Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 07-21-2005 Reviewed by: Name: STEVEN KOHN Address: STE4 2168 BALBOA AV SAN DIEGO CA92109 Permit #: CB052624 Job Name: MERINO DESIGN 8149 SF FROM Job Address: 1905 CALLE BARCELONA CBAD St: 226 INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0000571 Provide exit door hardware, which is openable from the inside without the use of a key or any special knowledge or effort. Show on door schedule location and type of hardware proposed. Note: Automatic door hold-open devices may require listed releasing devices when installed in rated assemblies. Doors shall be labeled to indicate that they are to remain unlocked during business hours. Entry: 07/21/2005 By: KV Action: CO MESRI ENGINEERING INC. STRUCTURAL CONSULTING 2180 GARNET AVE., SUITE 2E SAN DIEGO, CALIFORNIA 92109 IP] 858 273 8701, |F[ 858 273 6758 email: mlkemesri@aol.com MOVING THE 2500 POUND EQUIPMENT AT THE CARLSBAD FORUM BLDG #1 August 4, 2005 -. 20 -V oo 1^v' \ ( ^^> SO A To specify your title block on these five lines, use the SETTINGS main menu selection, choose the Printing & Title Block tab, and ent your title block information. Title: Dsgnr: Description Scope: Job# Date: 1:24PM, 4AUG05 Rev: 550100 User: KW-0604834, Ver 5.5.0, 25-Sep-2001 (c)1983-2001 ENERCALC Engineering Software Single Span Beam Analysis Page 1 Description CARLSBAD #1 EQUIP General Information Center Span Left Cantilever Right Cantilever Uniform Loads 18.00 ft ft ft Moment of Inertia Elastic Modulus Beam End Fixity \ 199.000 in4 29,000 ksi Pin-Pin I On Center Span... #1 0.322 k/ft On Left Cantilever... #1 k/ft On Right Cantilever... #1 k/ft Point Loads Magnitude Location Query Values Center Location Moment Shear Deflection K Summary Moments... Max + @ Center Max - @ Center @ Left Cant @ Right Cant Maximum = 0.470 k 0.470 k k 4.000 ft 12.000 ft ft 18.000ft Left Cant 0.00 k-ft -3.32 k 0.00000 in 3 Shears... 15.40 k-ft at 9.16ft ©Left 0.00 k-ft at 0.00 ft @ R'9ht Maximum0.00 k-ft 0.00 k-ft Deflections... @ Center 15'40k-ft ©Left Cant. @ Right Cant k ft 0.000 ft Right Cant 0.00 k-ft 0.00k 0.00000 in Reactions... 3.42 k @ Left 3.32 k @ Right 3.42 k -0.157 in at 9.02ft 0.000 in at 0.00ft 0.000 in at 0.00ft «mJl k ft 1 0.000 ft 0.00 k-ft 0.00 k 0,00000 in 3.42k 3.32k To specify your title block on these five lines, use the SETTINGS main menu selection, choose the Printing & Title Block tab, and ent your title block information. Rev: 550100 User: KW-0604834, Ver 5.5.0, 25-Sep-2001 (c)1983-2001 ENERCALC Engineering Software Description CARLSBAD #1 Single Span EQUIP Title : Job # Dsgnr: Date: 1:24PM, 4AUG05 Description : Scope : Roam Analueie Page 1 IUvCIIII micllyOlO I General Information | Center Span 18.00 ft Left Cantilever ft Right Cantilever ft Moment of Inertia Elastic Modulus Beam End Fixity 199.000 in4 29,000 ksi Pin-Pin Uniform Loads | On Center Span... #1 0.322 k/ft On Left Cantilever... On Right Cantilever... #1 k/ft #1 k/ft Point Loads f Magnitude 0.470 k Location 4.000 ft 0.470 k 12.000 ft k k k ft ft ft Query Values ( Center Location Moment Shear Deflection 18.000 ft Left Cant 0.000 ft Right Cant 0.000 ft 0.00 k-ft 0.00 k-ft 0.00 k-ft -3.32 k 0.00 k 0.00 k 0.00000 in 0.00000 in 0.00000 in 8 Summary Moments... Max + @ Center Max - @ Center @ Left Cant @ Right Cant Maximum = m 15.40 k-ft at 0.00 k-ft at 0.00 k-ft 0.00 k-ft 15.40 k-ft Shears... 9.16ft ©Left 0.00 ft © R'9ht Maximum Deflections... @ Center @ Left Cant. @ Right Cant 3.42 k 3.32 k 3.42 k -0.157 in at 0.000 in at 0.000 in at Reactions... ©Left @ Right 9.02ft 0.00ft 0.00ft 3.42 k 3.32 k "T M P- '< lf<34 To specify your title block on Title: Job # these five lines, use the SETTINGS Dsflnr: Da*e: 2:11PM, 4AUG05... . ,. DescnptTon:mam menu selection, choose the Printing & Title Block tab, and ent Scope • your title block information. rRwTssoToo"" «V~T „ _, I~~ , . " 'Dafv, " H User: KW-0604834, Ver 5.5.0, 25-Sep-2001 SlDCim SD3H H@am Ana IVSIS ra9e n (c)1983-2001 ENERCALC EnginaBrtna Software O• • IHIP O ptf M PB J111 Ml 1JIy tt l» ...__...._______ Description CARLSBAD #1^QUIP " ' »™^^~--™»^»^^^ General Information Center Span 18.00ft Moment of Inertia 340.000 in4 Left Cantilever ft Elastic Modulus 29,000 ksi Right Cantilever ft Beam End Fixity Pin-Pin Uniform Loads On Center Span... On Left Cantilever... On Right Cantilever... #1 0.334 k/ft #1 k/ft #1 k/ft Point Loads ,__ Magnitude 0.630 k 0.630 k k k k Location 4.000ft 12.000ft ft ft ft Query Values Center Location Moment Shear Deflection Summary Moments... Max + @ Center Max - @ Center @ Left Cant @ Right Cant Maximum - 18.000 ft o.oo k-n -3.57 k 0.00000 in Left Cant 0.000 ft o.oo k-ft 0.00 k 0.00000 in Right Cant 0.000 ft o.oo k-ft 0.00 k 0.00000 in 16.68 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft at at 16.68 k-ft Shears... 9.20 ft @ Left 0.00 ft @ R'9ht Maximum Deflections... @ Center @ Left Cant. @ Right Cant 3.71 k 3.57k 3.71 k Reactions. @Left @ Right 3.71 k 3.57 k -0.100 in at 9.02ft 0.000 in at 0.00 ft 0.000 in at 0-00 ft 0.63k 0.63k.3k ITTMTJ HTTH7] 1 R JTTTMMMIJ]' JTT 0.33 k/ft 18.00ft Mmax = 16.68 k-ft at 9.19 ft from left Dmax = -0.0997 in at 9.01 ft from left Rl = 3.705 k Vmax & left = 3.705 k Rr= 3.565k Vmax@rt= 3.565k 04-11-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR06016 Building Inspection Request Line (760) 602-2725 Job Address: 1905 CALLE BARCELONA CBAD St: 226 Permit Type: PCR Parcel No: 2550120400 Lot#: Valuation: $0.00 Construction Type: Reference #: CB052624 Project Title: MERINO HOMES INTERIOR COSMETIC CHANGES 0 NEW Applicant: MERINO DAVID STE3 7714 HOLLYWOOD BLVD LOS ANGELES CA 90046 323-436-2849 Status: ISSUED Applied: 02/03/2006 Entered By: KG Plan Approved: 04/11 /2006 Issued: 04/11/2006 Inspect Area: Owner: BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L C/0 DELOITTE TAX LLP PO BOX 131071 CARLSBAD CA 92013 Plan Check Revision Fee Additional Fees $120.00 $0.00 Total Fees:$120.00 Total Payments To Date:$120.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. . PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated By Date Address (include BIdg/Suite #) Legal Description Assessor's Parcel # ^ascription of Work__ ,- 1 Business Name (at this address) Lot No. ^Subdivision Name/Number Unit No. , Phase No. Total # of units Existing Use Proposed Use | , , SQ. FT. #of Stories # of Bedrooms # of Bathrooms Name Address City State/Zip Telephone # .•:.*•; >.,--**,>;„> (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requites the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). Name State License # Address License Class City State/Zip Citv Business License # Telephone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Fallura to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code. Interest and attorney's fees. SIGNATURE __ _._ DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: n I. as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). O I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES DlMO 2. 1 (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): , ___ PROPERTY OWNER SIGNATURE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES n NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all Citv ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void If the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit Is suspended or abandoned at any time after the work is commenced/rfVaperiod of 180 daysJggolon 106.4.4 Uniform Building Code). ^pPPLICANT'S SIGNATURE DATE LLOW: Applicant PINK: Finance PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CJL APPBKS RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10.000.001 DATE I-o<: ^^^—-^TENAWTTMPROVEMH*Tx PLAZA CAMINO REAL ' CARLSBAD COMPANY STORES VILLAGE PAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE EsGil Corporation In Partnership with government for 'Buitding Safety DATE: 3/20/06 a APPLICANT a JURIS. JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: 05-2624 (PCR06-016) SET: REV 1, Set II PROJECT ADDRESS: 1905 Calle Barcelona, Suite 226 PROJECT NAME: Merino Home Offices and Home Furnishing Display The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. CH The REMARKS check list below is transmitted herewith for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck, ~^\ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. CH The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. CH Esgil Corporation staff did advise the applicant that the plan check has been completed. ,*<*• \ Person contacted: Telephone #: / Date contacted: (by: ) If JF#x #: Mail Telephone Fax In Person KTrS REMARKS: The attached pyramid skylight detail must be included on the city set of plans to make an approved 2nd set of plans. / By: Chuck Mendenhall Enclosures: Esgil Corporationn GA n MB n EJ n PC FAX in 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In Partnership vntfi govtrnmtnt for ftidtding Safety DATE: 2/13/06 JURISDICTION: Carlsbad a PLAN REVIEWERa FILE PLAN CHECK NO.: 05-2624 (PCR06-016) SET: REV 1, Set I PROJECT ADDRESS: 1905 Calle Barcelona. Suite 226 PROJECT NAME: Merino Home Offices and Home Furnishing Display The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The REMARKS check list below is transmitted herewith for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. Submit responses and two sets of revised plans to Esgil or to the City BIdg Dept. for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Steven Kohn 2168 Balboa Ave., Suite 4, San Diego, CA 92109 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steven Kohn Telephone #: (858) 274-1812 Date contacted: 2HK (by: JA) Fax #: (858) 274-1433 Mail Telephone /^Fax f In Person \\^REMARKS: Provide the 1CBO approval or other agency approval for the pyramid skylight as shown detail 7/A4. if this is a custom built skylight provide design and construction details to demonstrate compliance with the code for skylights. End of review for revisions By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 2/6/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 4 Fax (858) 560-1576 Carlsbad 05-2624 (PCR06-016) 2/13/06 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 05-2624 (PCR06-016) PREPARED BY: Chuck Mendenhall DATE: 2/13/06 BUILDING ADDRESS: 1905 Calle Barcelona, Suite 226 BUILDING OCCUPANCY: B, M TYPE OF CONSTRUCTION: V N BUILDING PORTION Tl Rev Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) NA cb Valuation Multiplier Hrly By Ordinance Reg. Mod. VALUE ($) Plan Check Fee by Ordinance Type of Review; D Complete Review $120.00 IZ3 Repetitive Fee Repeats D Other m Hourly Structural Only Hour* Esgll Plan Review Fee $96.00 * Based on hourly rate Comments: Sheet 1 of 1 macvalue.doc