HomeMy WebLinkAbout191 CHERRY AVE; ; CB161976; PermitBuilding Permit Finaled
Residential Permit
Print Date: 10/06/2020
Job Address:
Permit Type:
Parcel#:
Valuation:
191 CHERRY AV, CARLSBAD, CA
BLDG-Residential
2042320100
$478,802.00
Occupancy Group:
#of Dwelling Units: 1
Bedrooms:
Bathrooms:
ProjectTitle: CHERRYFIELD BEACH HOMES
Work Class: Condo
Track#:
Lot#: 2
Project#: DEV15033
Plan#:
Construction Type:
Orig. Plan Check#: PC160031
Plan Check#:
Status:
Applied:
Issued:
(city of
Carlsbad
Permit No: CB161976
Closed -Finaled
05/19/2016
10/11/2017
Finaled Close Out:
Inspector:
Final Inspection:
TFraz
10/06/2020
Description: CHERRYFIELD TOWNHOMES:(UNIT 2) 3,372 SF LIV// 428 SF GAR// 560 SF DECKS
FEE
BUILDING PERMIT FEE $2000+
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FE.ES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement
STRONG MOTION-RESIDENTIAL
TRAFFIC IMPACT Residential Condo Outside CFD
WATER METER FEE 1" Displacement
WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 5/8" Displacement
Total Fees: $32,507.78 Total Payments To Date: $32,507.78
CoApplicant:
PROPHET SOLUTIONS INC
5845 AVENIDA ENCINAS, # 138
CARLSBAD, CA 92008-4432
(760) 999-2146
Balance Due:
AMOUNT
$1,971.45
$880.02
$66.00
$166.00
$92.00
$182.00
$16,758.07
$20.00
$5,029.00
$62.24
$2,632.00
$352.00
$4,169.00
$128.00
$0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Building Division Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY for (CB161976)
Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner:
Work Class: Condo Issue Date: 10/11/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 191 CHERRY AV
IVR Number: 714645 CARLSBAD.CA
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
09/08/2020 09/08/2020 BLDG-Final Inspection 137615-2020 Failed Paul Burnette Re inspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
10/06/2020 10/06/2020 BLDG-Final Inspection 140239-2020 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Plumbing Final Yes
BLDG-Mechanical Final Yes
BLDG-Structural Final Yes
BLDG-Electrical Final Yes
Tuesday, October 6, 2020 Page 5 of 5
PERMIT INSPECTION HISTORY for (CB161976)
Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner:
Work Class: Condo Issue Date: 10/11/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 191 CHERRY AV
IVR Number: 714645 CARLSBAD,CA
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 6" rigid foam over vaulted area Yes
Wall and Ceiling insulation OK 3/14/19
03/28/2019 03/28/2019 BLDG-17 Interior 087255-2019 Passed Tim Frazee Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/01/2019 04/01/2019 BLDG-18 Exterior 087576-2019 Passed Tim Frazee Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/26/2019 04/26/2019 BLDG-84 Rough 090120-2019 Passed Michael Collins Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Gage metal hard lid drops and soffits Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
02/14/2020 02/14/2020 BLDG-22 Sewer/Water 119590-2020 Passed Michael Collins Complete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Building supply from meter to unit Yes
04/15/2020 04/15/2020 BLDG-23 124811-2020 Passed Michael Collins Co~plete
Gas/Test/Repairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency EMR emailed to SDGE Yes
BLDG-Electric Meter 124935-2020 Passed Michael Collins Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency EMR emailed to SDGE Yes
06/22/2020 06/22/2020 BLDG-34 Rough 130777-2020 Passed Paul Burnette Complete
Electrical
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Yes
Tuesday, October 6, 2020 Page 4 of 5
PERMIT INSPECTION HISTORY for (CB161976)
Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner:
Work Class: Condo Issue Date: 10/11/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 191 CHERRY AV
IVR Number: 714645 CARLSBAD, CA
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Re inspection Inspection
Date Start Date Status
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Upper roof except star tower No
BLDG-Building Deficiency Flat roof deck nailing.OK to build cricket. Yes
Need height certification before roof
inspection.
12/11/2018 12/11/2018 BLDG-24 Rough/T opout 078457-2018 Partial Pass Paul Burnette Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
12/13/2018 12/13/2018 BLDG-15 Roof/ReRoof 078765-2018 Partial Pass Michael Colllns Reinspection Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency OSB over rigid foam Yes
BLDG-Building Deficiency Upper roof except star tower No
BLDG-Building Deficiency Flat roof deck nailing.OK to build cricket. Yes
Need height certification before roof
inspection.
BLDG-16 Insulation 078766-2018 Partial Pass Michael Colllns Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 6" rigid foam over vaulted area Yes
01/04/2019 01/04/2019 BLDG-13 Shear 080486-2019 Passed Tim Frazee Complete
Panels/HD (ok to wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
02/12/2019 02/12/2019 BLDG-16 Insulation 083658-2019 Partial Pass Paul Burnette Reinspection Incomplete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 6" rigid foam over vaulted area Yes
03/04/2019 03/04/2019 BLDG-84 Rough 084967-2019 Passed Tim Frazee Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
03/14/2019 03/14/2019 BLDG-16 lnsulatlon 086150-2019 Passed Tim Frazee Complete
Tuesday, October 6, 2020 Page 3 of 5
PERMIT INSPECTION HISTORY for (CB161976)
Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner:
Work Class: Condo Issue Date: 10/11/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 191 CHERRY AV
IVR Number: 714645 CARLSBAD.CA
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
04/12/2018 04/12/2018 BLDG-21 054763-2018 Passed Paul Burnette Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/17/2018 04/17/2018 BLDG-12 Steel/Bond 055312-2018 Partial Pass Michael Collins Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency HSS column tie in to CMU, see card Yes
BLDG-Building Deficiency 8" poured in place wall at shoring/ stairwell Yes
04/30/2018 04/30/2018 BLOG-11 056434-2018 Partial Pass Paul Burnette Reinspection Incomplete
Foundatlon/Ftg/Plers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
05/10/2018 05/10/2018 BLDG-11 057635-2018 Partial Pass Paul Burnette Reinspection Incomplete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
09/12/2018 09/12/2018 BLDG-14 069772-2018 Failed Michael Collins Re inspection Incomplete
Frame/Steel/Bolting/We
ldlng (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
09/18/2018 09/18/2018 BLDG-11 070339-2018 Passed Paul Burnette Complete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG•Building Deficiency No
10/09/2018 BLDG-15 Roof/ReRoof 072214-2018 Partial Pass Chris Renfro Reinspectlon Incomplete
(Patio)
Checklist Item COMMENTS Passed
BLOG.Building Deficiency Flat roof deck nailing.OK to build cricket. Yes
Need height certification before roof
inspection.
11/13/2018 11/13/2018 BLDG-15 Roof/ReRoof 075873-2018 Partial Pass Michael Collins Reinspection Incomplete
(Patio)
Tuesday, October 6, 2020 Page 2 of 5
Building Permit Inspection History Finaled
(city of
Carlsbad
PERMIT INSPECTION HISTORY for (CB161976)
Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner:
Work Class: Condo Issue Date: 10/11/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 191 CHERRY AV
IVR Number: 714645 CARLSBAD.CA
Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection
Date Start Date Status
11/21/2017 11/21/2017 BLDG-11 041160-2017 Passed Michael Collins Complete
Foundation/Fig/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Lower CMU footing/steel Yes
12/11/2017 12/11/2017 BLDG-11 042981-2017 Passed Chris Renfro Complete
Foundatlon/Ftg/Piers
(Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-66 Grout 042980-2017 Passed Chris Renfro Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/04/2018 01/04/2018 BLDG-66 Grout 045016-2018 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/26/2018 01/26/2018 BLDG-12 Steel/Bond 046976-2018 Partial Pass Andy Krogh Reinspection Incomplete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 8" poured in place wall at shoring/ stairwell Yes
03/14/2018 03/14/2018 BLDG-21 051716-2018 Failed Paul Burnette Reinspection Incomplete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-22 Sewer/Water 051717-2018 Failed Paul Burnette Reinspection Incomplete
Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03/19/2018 03/19/2018 BLDG-21 052092-2018 Passed Michael Collins Complete
Underground/Underflo
or Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
Tuesday, October 6, 2020 Page 1 ol 5
Construction Testing & Engineering, Inc.
··-·-·------·---·-·-__ .,_ -·--· --···
lnspecllon I Testlng I Geolechnlcal I Environmental & Construclion Engineering I Civil Engineering I Surveying
DAILY FIELD REPORT
Client: Proohet Solutions Job Number: 10-13893T
Job: Name: Che= Field Beach Homes Day( 5): Wednesdav
Job Location: 187, 191, 195, Chenv Ave. Carlsbad, CA 92009 Date(s): 12-19-18
Gen. Contractor:
Sub Contractor(s):
General Description:
195, Cherry Ave unit #1, permit number: CB161977
191, Cherry Street unit #2, permit number: CB161976
187, Cherry Streetunlt#3, permit number: CB161974
Engineer: La Costa Engineering
Shearwall Inspection
Inspected the Shear walls for buildings 1, 2 and 3 per sheets S2, S3, S4, S5 and the shear wall schedule on sheet SN3.
Verified materials, nailing, hold-down, foundation connection and shear transfer between floors/roof, Installation is compliant
with the approved plans except for the items listed on the areas of additional concern.
*Re-Inspection is required to check areas of concern.
• PLEASE NOTE ANY RE-INSPECTION/TESTING
COMMENTS/ AREAS OF ADDITIONAL CONCERN
Unit #1, level 2, shear transfer top plate to rim, A35 6"0/c on grid line D between grid line 3 through 3.5.
Unit #2, level 2, shear transfer top plate to rim, A35 6"0/c on grid line F between grid line 4 through 4.2.
Unit #2, level 2, shear transfer 3X bottom plate to joist below at grid fine 6 .
. Unit #3, deck level, shear transfer 3X bottom plate to rim below at grid line E.8/6.6.
___, /
~····•· BY: Bill Atwood .'1/·· ··::;r· -·-· ---DATE: 12-19-18
CERTIFICATION NO: 5012754 rurc =-
T
1441 MONTIEL ROAD ESCONDIDO, CA92026 (760) 746-4955 FAX (760) 746-9806
b~A,lnc.
land planning, civil engineering, surveying
November 29, 2017
w.o. 1001-1113-600
Mr. Paul Burnette
Senior Building Inspector
CITY OF CARLSBAD
Community and Economic Development
Building Division
1635 Faraday Avenue
Carlsbad, CA 92008
ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
RE: BUILDING LAYOUT AND SET BACK VERIFICATION OF UNITS 1, 2 AND 3,
CHERRY-FIELD BEACH HOMES, MS 15-08
Dear Mr. Burnette:
This letter is to attest that BHA, Inc. has staked the location for the building construction on
the above-mentioned units. In addition we have checked the layout of the proposed building
and found the horizontal and vertical location to conform to the grading plans prepared by our
office.
If you have any questions regarding this matter, please contact our office.
Sincerely,
Vice President
PLS5941
AAM:
cc: Randy Smith -Prophet Solutions
5115 Avenida Encinas, Suite L ° Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying
INSPECTION REPORT
PROJECT NAME ---=--'-""""''-+-,''---1--,/'--"'--'-'0::Z.......,..-'-!CJ'-=!..l~~ .... ,S. INSPECTION
ADDRESS ..µ,::.zf:..s...,.....LC'W--f-.£.7':_!__-=-4-4----LJ~=---0 CONCRETE
□
d <!'h~□ ARCHITECT
ENGINEER
CONTRACTOR
OTHER
INSPECTION DATE
/4 C,.,s t1 ~p;z.&.Rt;,_ 5 □
t'rt;,oAd-:lo1ahn,s l1tc, □
7
□
PLAN FILE/OTHER Pc I t..oo:3/
BLDG. PERMIT/OTHER
REINF. STEEL
MASONRY
P.T. CONCRETE
FIELD WELDING
SHOP WELDING
PAGE _j__ OF _j__
CTE JOB NO./t;7-/3'iJ] _3'
REPORT NO.
MATERIAL IDENTIFICATION
CONC. MIX NO. & lb/in2
GROUT MIX NO. & lb/in2
MORT AR TYPE & lb/in2
REINF. STEEL GR./SIZE If ~t)~ /4 ~I)-
7
STRUCTURAL STEEL
HIGH-STRENGTH BOLT
MASONRY BLOCK
OTHER
-----
-~
0 BATCH PLANT
0 EXP. ANCHOR
0 OTHER --------------~~
MATERIAL SAMPLING
' □ CONCRETE □ MORTAR □ GROUT □ FIREPROOFING □ MASONRY BLOCK
□ REINFORCING STEEL □ STRUCTURAL STEEL □ SOL TS □ OTHER "'
INSPECTfONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES.
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the appr_?\'.ed plans and specifications.
1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
b~A,lnc
land planning, civil engineering, surveying
October 9, 2018
w.o. 1001-1113-100
Mr. Paul Burnette
Building Inspector
CITY OF CARLSBAD
Community and Economic Development
Building Division
1635 Faraday Avenue
Carlsbad, CA 92008
o~~
~G
0~ ~~G ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
NOISl/\10 8NIO7\nS
8lOZ 6 iJO City "f "--'"'e;bad
peqstJi~ io Al!:l q .. j Cily of Carlsbad ·
, I ulVlS!C. J
OCT 9 2018
BUILDING DIVISION
RE: ROOF HEIGHT VERIFICATION OF UNITS 1 THRU 3, 187, 191 & 195 CHERRY
AVENUE, CHERRY-FIELD BEACH HOMES, MS 15-08
Dear Mr. Burnette:
This letter is to attest that BHA, Inc. has surveyed the roof height of the building for the
above-mentioned project.
The top of roof elevation for the center ridge line is shown on the building plans dated 01-04-
2018 as 91.0'. We have surveyed the elevation of the existing roof at the center ridge line as
90.94'.
Th"e top of roof elevation for the flat roof is shown on· the building plans dated 01-04-2018 as
85.0'. We have surveyed the elevation of the existing flat roof as 84.93'.
If you have any questions regarding this matter, please contact our office.
Sincerely,
b~A, Inc. -~~ \i~Al?A/
Ronald L. Holl-ow-a~--6
Senior Vice President
RCE 29271
RH:rh
cc: Matthew Castriotta
Randy Smith -Prophet Solutions
K:\Land Projects 3\826-1113-600\survey\roof height-verification-cherry.wpd
51 15 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780