HomeMy WebLinkAbout1911 CALLE BARCELONA; 150; CB030671; PermitL City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
09-04-2003 Commercial/lndustrial Permit Permit No: CB030671
Building Inspection Request Line (760) 602-2725
Job Address: 191 1 CALLE BARCELONA CBAD St: 150
Permit Type: TI Sub Type:
Parcel No: Lot #:
Valuation: $286,650.00 Construction Type:
Occupancy Group: Reference #:
Project Title: TILLY'S
9,955 SF IMPROVEMENT
Applicant:
DATUM ARCHITECTS
STE 111
6 MORGAN
IRVINE 92618
949 581-2255
COMM 0 Status: ISSUED
NEW Applied: 03/06/2003
Plan Approved: 05/27/2003
Issued: 09/04/2003
Entered By: MDP
Inspect Area:
Plan Check#:
Owner:
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Recl. Water Con. Fee
$1 ,I 22.52
$0.00
$729.64
$0.00
$0.00
$60.20 $0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
$0.00 $0.00
$0.00
$0.00
Meter Size
Add'l Recl. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF
PFF (CFD Fund)
License Tax
License Tax (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00 $0.00 $0.00
$5,217.03
$0.00 $0.00 $0.00
$0.00
$0.00
$55.00
$60.00
$33.00
$0.00
$0.00 $0.00
$0.00
$7,277.39
Total Fees: $7,277.39 Total Payments To Date: $729.64 Balance Due: $6,547.75
3328 09/04/03 W2 01 02
CGF 6547.75
follow the protest procedures set forth in Government Code Section 66020(6), and file the protest and any other required informtion with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
- PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK ~0.03 -67 1
EST. VAL. w Plan Ck. Deposit
Validated By t
Date XI 31
Subdivision NamelNumber Phase No. Total # of units Unit No. Legal Description Lot No.
Proposed Use
PmNIr) Assessor's Parcel # Existing Use
# of Bathrooms Description of Work SO. FT. #of Stories # of Bedrooms
licant)
Name Address city Statelzip Telephone # Fax #
Name Address city Statelzip Telephone #
(Sac. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
148 22-6 qqy 2
City StatelZi
City Business License #
Name
State License # ~qc70 +C3
Designer Name Address City Statelzip Telephone
License Class
State License #
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 of the work for which this permit is issued.
0
issued. My worker's com-n insurance c
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1$1001 OR LESS)
0
to become subject to th
WARNING: Failu
thousand dollars (
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which thi per it IS
Expiration Date & 10 0 3
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit IS issued, I shall not employ any person in any manner so as
d policy number are: % 1?453'3
Insurance Company CY..! Pollcy NO.o+f -02-
sation Laws of California.
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0
1.
2.
3.
I am exempt under Section
I personally plan to provide the malor labor and materials for constructton of the proposed property improvement. YES
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
Business and Professions Code for this reason:
ON0
4.
number I contractors license number):
5.
of work):
PROPERTY OWNER SIGNATURE DATE
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
IS SECTION FOR NDhWESIDBVTIAL BUILMNG PERMI
Is the applicant or future building occupant required to submit a bu
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
0 YES 0 NO
0 YES 0 NO
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA. An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit IS suspended or abandoned
at any time after the work is corn
APPLICANT'S SIGNATURE DATE 3/($b3 0 days (Section 106.4.4 Uniform Building Code).
W WHITE: File YELLOW: Applicant PINK: Finance
City of Carlsbad
Final Building Inspection
Dept: Building Engineering Planning
Plan Check #:
Permit #: CB030671
Project Name: TILLY'S
Address: 191 1 CALLE BARCELONA #150
9,955 SF IMPROVEMENT
CMWD
Date:
Permit Type:
Sub Type:
Lot: 0
1 111 712003
TI
COMM
Contact Person: TOM
Sewer Dist:
Phone: 61 98908463
Water Dist: ..........................................................................................................................................................
Inspected
By: & 4 Date Inspected: Rhh3 Approved: /Disapproved:
Date Inspected
By: Inspected: Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved:
U
...........................................................................................................................................................
Comments:
City of Carlsbad Bldg Inspection Request
For: 1 1/25/2003
Permit# CB030671
Title: TILLY'S
Description: 9,955 SF IMPROVEMENT
Type: TI Sub Type: COMM
Job Address: 191 1 CALLE BARCELONA
Suite: 150 Lot 0
Location:
APPLICANT DATUM ARCHITECTS
Owner:
Inspector Assignment: PS
Phone: 61 98908463
InsDector: 95
Remarks: ER FOR YOU-
Total Time: Requested By: TOM
CD DescriDtion Act Comment
Entered By: CHRISTINE
19 Final Structural
29 Final Plumbing
39 Final Electrical /- 49 Final Mechanical
Associated PCRs/CVs
PCR03199 ISSUED TILLYS-ADD ROOF MOUNT EQUIPMEN; & RE-ORGANIZE DATA ON REMAINING SH
PCR03250 ISSUED TILLYS DEFERRED SUBMlTAL BACKROOM STORAGE SHELVING
Inspection History
Date Description
1 1 /20/2003 89
1 111 712003 89
11/05/2003 29
11/05/2003 39
11/05/2003 49
10/24/2003 14
10/22/2003 17
10/22/2003 18
10/21/2003 17
1011 712003 14
10/03/2003 17
10/02/2003 17
10/01/2003 14
09/30/2003 14
09/30/2003 34
Final Combo
Final Combo
Final Plumbing
Final Electrical
Final Mechanical
Frame/Steel/BoltingWelding
Interior Lath/Drywall
Exterior LathIDrywall
Interior LatNDrywall
Frame/Steel/BoltingWelding
Interior Lath/Drywall
Interior LathlDrywall
Frame/SteellBoltin@Velding
FramelSteellBoltingWelding
Rough Electric
Act lnsp Comments
co PS
CO PS OKTOSTOCK
co PS
CO PS EMR co PS
AP PS ROOFUNITS
AP PS
AP PS
NR PS
PA PK NORTH EXT WALL OK TO LATH AND ROCK
AP PS
CA PS BYTOM
AP PS CURBSFORHVAC
PA PS SOFFITS
PA PS
Inspection List
Permit#: CB030671 Type: TI
Date Inspection Item
1 1 /25/2003 89
1 1 /25/2003 89
1 1 /24/2003 89
1 1 /24/2003 89
11/20/2003 89
11/20/2003 89
1111 712003 89
1111 712003 89
11/05/2003 29
11/05/2003 39
11/05/2003 49
10/24/2003 14
10/22/2003 17
10/22/2003 18
10/21/2003 17
1011 712003 14
10/03/2003 17
10/02/2003 17
1 010 1 I2003 14
09/30/2003 14
09/30/2003 34
09/30/2003 44
09/29/2003 17
09/29/2003 34
09/29/2003 44
09/25/2003 17
09/23/2003 13
09/23/2003 16
0911 912003 14
0911 912003 34
0911 812003 14
0911 8/2003 24
0911 812003 34
0911 612003 1 1
0911 512003 1 1
0911 212003 21
0911 2/2003 31
0911 1 I2003 21
0911 112003 31
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Plumbing
Final Electrical
Final Mechanical
FramelStee WBoltingNeldin
Interior Lath/Drywall
Exterior Lath/Drywall
Interior LathIDrywall
Frame/Steel/BoltingNeldin
Interior LathIDrywall
Interior LathIDrywall
Frame/Steel/BoltingNeldin
FramelSteellBoltingNeldin
Rough Electric
Rough/Ducts/Dampers
Interior LathIDrywall
Rough Electric
Rough/Ducts/Dampers
Interior LathIDrywall
Shear PanelsIHD's
Insulation
Frame/Steel/BoltingNeldin
Rough Electric
Frame/Steel/BoltingNeldin
Roug hlTopout
Rough Electric
Ftg/Foundat ion/Piers
FtgIFoundat ion/Piers
UndergroundIUnder Floor
UndergroundIConduit-Wirin
UndergroundIUnder Floor
Underground/Conduit-W irin
COMM TILLY'S
9,955 SF IMPROVEMENT
Inspector Act Comments
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PK
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PD
PD
PS
PS
PS
PS
PS
PS
PS
PS
PS
AP
RI
RI
co
RI
co
RI
co
co co
co
AP
AP
AP
NR
PA
AP
CA
AP
PA
PA
NR
PA
CA
CA
AP
AP
AP
PA
PA
co
AP
co
CA
AP
AP
AP
CA
CA
HAS THE LETTER FOR YOU-
OK TO OPEN
FINAL TO MERCHANDISE ONLY
OK TO STOCK
EMR
ROOF UNITS
NORTH EXT WALL OK TO LATH AND
ROCK
BY TOM
CURBS FOR HVAC
SOFFITS
SOFFITS
HlGHLlTED ORANGE
PLYWOOD
WALLS
SEE NOTICE ATTACHED
NEED 41N VENT
DONE ON 911 5
POUR BACK
BY TOM
Wednesday, November 26,2003 Page 1 of 1
City of Carlsbad Bldg Inspection Request
For: 09/18/2003
Permit# CB030671
Title: TILLY'S
Description: 9,955 SF IMPROVEMENT
Type: TI Sub Type: COMM
Job Address: 191 1 CALLE BARCELONA
Suite: 150 Lot 0
Location:
APPLICANT DATUM ARCHITECTS
Owner:
Remarks:
Total Time:
Inspector Assignment: PS
Phone: 61 98908463
Inspector: 22
Requested By: TOM
Entered By: CHRISTINE 29 Comment
CD Description
14 FrarnelSteeVBoltingMIelding ~
24 Rough/Topout &em em c %f '?L/
34 Rough Electric &k
Associated PCRs/CVs
Inspection History
Date Description Act lnsp Comments
09/16/2003 1 1 Ftg/Foundation/Piers CA PS DONEON9/15
09/15/2003 11 Ftg/Foundation/Piers AP PS POURBACK
09/12/2003 21 UndergroundNnder Floor AP PS
09/12/2003 31 Undergroundlconduit-Wiring AP PS
09/11/2003 21 UndergroundlUnder Floor CA PS BYTOM
09/11/2003 31 UndergroundlConduit-Wiring CA PS
PCR03199 PENDING TILLYS-ADD ROOF MOUNT EQUIPMEN; & RE-ORGANIZE DATA ON REMAINING SH
CITY OF CARLSBAD NOTICE (760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
1 FOR INSPECTION 602-2725. RE-INSPECTION FEE DUE? LA YES
PHONE
@ CODE ENFORCEMENT OFFICER
ESGT Corporation
In Partnership with Government for Q)uiling safety
DATE: 5/22/03
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 03-671
R APPLICANT
R JURIS.
R PLAN REVIEWER
R FILE
SET: I11
PROJECT ADDRESS: 191 1 Calle Barcelona Suite 150
PROJECT NAME: TiUy’s - TI
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
IXI The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified in the remarks below are resolved and checked by building
department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant
0 The applicant‘s copy of the check list has been sent to:
contact person.
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1
REMARKS: Applicant to add note in red to
Mail Telephone Fax In Person
to City held sets.
By: Doug Moody Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 5/16/03 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 (858) 560-1468 + Fax (858) 560-1576
EsGil Comoration
In Partnership with Government for @uit&ng safety
DATE: 4/18/03
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 03-671 SET: I1
PROJECT ADDRESS: 1911 Calle Barcelona Suite 150
PROJECT NAME: Tilly’s - TI
0
0
w
o
w
o w
0 PLAN REVIEWER
0 FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Datum Architects
6 Morgan Suite I1 1 Irvine, CA 92618
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Datum Architects
Date contacted: Y I d D 3 (by: (-A >o
REMARKS:
Telephone #: 949-581 -2255
Fax #: 949-587-1263
Mail - Telephone Fax./ In Person
By: Doug Moody Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 411 1/03 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 03-671
4/ 18/03
RECHECK PLAN CORRECTION LIST
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-671
PROJECT ADDRESS: 191 1 Calle Barcelona Suite 150 SET: I1
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 4/11/03 I DATE RECHECK COMPLETED:
4/18/03
IREVIEWED BY: Doug Moody N
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A. Please make all corrections on the original tracings and submit three new sets of prints to:
ESG I L CORPORATION.
B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C. The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
D. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
OYes ONo
'- .
City of Carlsbad 03-671
4/18/03
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculationslreports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
These corrections are in response to items not fully addressed or as the
result of information provided, the text in bold print indicates the
unresolved issue.
3. Provide framing plans for the new display soffits. Show:
b) Method of attaching top to the structure and lateral bracing. Please
indicate the method of attaching the cantilevered joists to the
box headers and the full height wall equal to the uplift force.
5. Please revise the plans to show the door to display areas to be disabled
accessible. Display areas which exceed 200 square feet are required to be
accessible. Please revise the plans to show the display areas to equal the
square footage indicated on the plans.
EsGil - Corporation
In Partnership with government for QuiGiiing Safety
DATE: 3/20/03
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 03-671
0 FILE
SET: I
PROJECT ADDRESS: 191 1 Calle Barcelona Suite 150
PROJECT NAME: Tilly’s - TI
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Datum Architects
6 Morgan Suite 11 1, Irvine, CA 92618
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Datum Architects (M [CHf Telephone #: 949-581 -2255
Date contacted: 3)~~/a3 (by: GL )
Mail Telephone/ Fax 1 In Person 0 REMARKS:
By: Doug Moody Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 311 0103
Fax #: 949-587-1263
tmsmtl.dot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576
City of Carlsbad 03-671
3/20/03
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 03-671
OCCUPANCY: M USE: Retail
TYPE OF CONSTRUCTION: VN ACTUAL AREA: 9555sf
ALLOWABLE FLOOR AREA: STORIES: 1
J U Rl SDl CTl ON : City of Carlsbad
HEIGHT:
SPRINKLERS?: YES OCCUPANT LOAD: 245
REMARKS:
DATE PLANS RECEIVED BY
J U R I S DI CTI ON : 3/6/03 ESGIL CORPORATION: 3/10/03
DATE INITIAL PLAN REVIEW PLAN REVIEWER: Doug Moody
COMPLETED: 3/20/03
FOREWORD (PLEASE READ):
DATE PLANS RECEIVED BY
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed UP the recheck process, please note on this list (or a COPY) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
tiforwdot TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)
City of Carlsbad 03-671
3/20/03
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
I. Please provide plans and calculations signed by the California State licensed
engineer or architect for the structural support of the rooftop air handler units.
Include all calculations and finding on the plans. Please include the California
license number, seal, date of license expiration and date plans are signed.
Business and Professions Code.
2. Please revise the wall legend to be consistent with detail D on sheet 7 to show
the studs to be a minimum of 20 gauge.
3. Provide framing plans for the new display soffits. Show:
a)
b)
c)
d)
Type, size and spacing of studs. Indicate gauge for metal studs. Specify
manufacturer and approval number or indicate "to be ICBO approved".
Method of attaching top to the structure and lateral bracing.
Wall sheathing material and details of attachment (size and spacing of
fasteners).
Show height of the soffit from floor, soffit to roof framing or floor framing.
4. Please revise the plans to show the office to comply with section 1004.2.2. Exits
shall not pass through kitchens, storerooms, or spaces used for similar
purposes. Section 1004.2.2.
5. Please revise the plans to show the door to display areas to be disabled
accessible. Display areas which exceed 200 square feet are required to be
accessible.
6. Please revise the plans to show the required emergency egress lighting per
section 1003.2.9 of the UBC.
City of Carlsbad 03-671
3/20/03
7. Please note on the plans “AC Cable is not allowed in A, B, E, H, and I
occupancies. NM cable is restricted (without City approval) to one and two
family dwellings. Note on plans that an equipment ground conductor is to be
installed in all flexible conduits”.
8. Show that the minimum strike edge distances are provided at the level area on the
side to which a door swings for the door to restroom 108, per Section
I 1338.2.4.3:
a) 218” at interior conditions.
9. Show that the space between two consecutive door openings in a vestibule, which
serves spaces other than a required exit stairway:
a) Provide 248” clear space from any door opening into the vestibule when door is open 90°, per Section 1 1338.2.4.4.
b) Doors in series shall swing either:
i) In the same direction.
ii) Away from the space between the doors.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
8581560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad 03-671
3/20/03
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-671
PREPARED BY: Doug Moody
BUILDING ADDRESS: 1911 Calle Barcelona Suite 150
BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN
DATE: 3/20/03
Jurisdiction Code cb By Ordinance I
1994 UBC Building Permit Fee T I I $1,122.521
1994 UBC Plan Check Fee v I $729.641
Type of Review: El Complete Review 0 Structural Only
07 Fee Repeats
0 Other
~ouriy n Hour*
Esgil Plan Review Fee cl I $628.61 1
Comments:
Sheet 1 of 1
macvalue.doc
PLANNINCIENGINEERING APPROVALS
PERMIT NUMBER CB 0% 1 DATE
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL
(e $10,000.00)
CARLSBAD COMPANY STORES
VILLAGE FAlRE
COMPLETE OFFICE BUILDING
OTHER
- Cadsbad Fire Department 030671
1635 Faraday Ave.
b Carlsbad, CA 92008 Fire Prevention
(760) 602-4660
Plan Review Requirements Category: Building Plan
Date of Report: 3.10.03 Reviewed by:
Name: DATUM ARCHITECTS
Address: 6 MORGAN SUITE 11 1
Plan Checker:
City, State: IRVINE CA 92618
Job #: 030671
Job Name: Tilly's #I 50 Bldg #: CB030671
Job Address: 191 1 Calle Barcelona Ste. or Bldg. No. 150
Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
0 Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2nd 3rd Other Agency ID
FD Job # 030671 FD File #
, Reqqirements Category: Building Plan
‘r Requirement: Pending 05.1 1 Knox Box
Knox Box required when access to or within a structure or an area is unduly difficult because of
secured openings or where immediate access is necessary for life saving or fire-fighting purposes.
The Fire Department will determine the location for the key box and provide an authorized order
form.
Page 1 03.1 0.03
a. 3
ICBO Evaluation Service, Inc.
5360 WORKMAN MILL ROAD WHITTIER, CALIFORNIA 90601-2299
A subsidiary corporation offhe International Conference of Building Officials
EVALUATION REPORT Copyn.ght 0 2000 ICBO Evaluation Service, Inc.
ER-1372
Reissued March 1,2000
Filing Category: FASTENERS-Concrete and Masonry Anchors (066)
ITW RAMSET/RED HEAD SELF-DRILLING, TRUBOLT WEDGE, AND MULTI-SET II CONCRETE ANCHORS
ITW RAMSET/RED HEAD 1300 NORTH MICHAEL DRIVE WOOD DALE, ILLINOIS 60191
1.0 SUBJECT
ITW RamsetlRed Head Self-Drilling, TruboR Wedge, and MultiSet II Concrete Anchors.
2.1 ITW RarnsetlRed Head See-Drilling Anchor:
2.1.1 General: The ITW RamseURed Head anchor is a self- drilling concrete expansion shell anchorwith a single coneex-
pander. Both elements are made from heat-treated steel. The steel for the body conforms to AIS1 Cl2Ll4, and the steel for theplugconforrnstoAlSlC-lOl0.Theanchorhaseightsharp teeth at one end and is threaded internally at the other end. The outer surface of the tubular shell at the toothed end has annular broaching grooves and four milled slits. At its threaded end, the anchor is provided with an unthreaded chucking cone that has an annular break-off groove at its base for flush mounting. Anchor shell and expander cone are electrodeposit zinc and chromate-plated.
2.1.2 Installation: Embedment, spacing, edge distance, and concrete requirements are shown in Tables 1 and 2. The anchors are installed by a Model 747 Roto-Stop Hammer, by air or electric impact hammer, or by hand. The anchor is used as a drill in forming the hole in normal-weight concrete. After the hole is formed, the anchor must be removed and the hole thoroughly cleaned. The hole depth is regulated by the drill chuck. A Red Head plug must be set into the bottom of the an- chor prior to insertion in the hole. The concrete anchor must be driven over the plug, to cause expansion of the anchor in the hole. The chucking end of the anchor is broken off with a hammer blow. Verification that the anchor has been installed properly is evidenced by the fact that the anchor does not project above the surface of the concrete and the red plug is visible at the bottom of the hole.
2.2 ITW RamseURed Head Trubolt Wedge Anchor:
2.2.1 General: The Trubolt Wedge anchor is a stud bolt type of dropin anchor. The anchors are cold-formed or machined from zinc-plated and chromate-dipped carbon steel, hot-
dipped galvanized carbon steet or stainless steel. Steel used to produce the anchors complies with AIS1 C-1015 to AIS1 C-1022 and AIS1 C-1213 carbon steels, Type 304 or Type 31 6 stainless steels. Hot-dipped galvanizing complies with ASTM 153 Class C requirements. The expander sleeves are fabri- cated from stainlesssteel or carbon steel meeting the require-
2.0 DESCRIPTION
ments of Type 302 or AIS1 C-1010, respectively. Cold-formed anchor studs are available only for the '/d-inch-, 3/8-inch-,
'G-inch-, 5/8-inch- and a/d-inch-diameter (6.4,9.5,12.7, 15.9 and 19.1 mm) wedge anchors. The anchor stud is threaded at its upper end and has a straight cylindrical section reduced in diameter, around which the expander sleeve is formed. A
straight-tapered seclion enlarging to a cylindrical base actsto increase the diameter of the expander ring as the stud is tight- ened in the concrete hold. The expander ring, which is formed around the stud bolt, consists of a spii-ring element with a "coined" groove at each end. The expander ring is designed
to engage the walls ofthe concrete hold as the tapered portion of the stud is forced upward against its interior.
2.2.2 Installation: Embedment, spacing, edge distance, and concrete requirements are shown in Tables 3,4, 5 and IO. Holes must be predrilled in normal-weight or lightweight concrete with carbide-tipped masonry drill bits manufactured within the range of the maximum and minimum drill tip dimen- sions of ANSI 8212.15-1994. The anchors must be installed in holes the same nominal size as the anchor size, with a greater depth than the length of embedment desired, but no less than the minimum embedment. The hole must be cleaned out prior to installation of the anchor. The anchor must be tapped into the hole to the embedment depth desired, but no less than the minimum embedment. A standard hexag- onal nut and washer must be used over the material being fastened and the nut tightened until the minimum installation torque, as indicated in Tables 3 and IO, is reached.
2.3 ITW RamsetlRed Head Multi-Set I1 Anchor:
2.3.1 General: The Multi-Set anchors are designed to be installed in a predrilled hole equal to the anchor diameter. The anchor consists of a shell formed from carbon steel meeting the minimum requirementsof AIS1 C-1213 and an expansion plug formed from carbon steel meeting the minimum require- ments of AIS1 C-1010. The expansion end is divided into four
equal segments by radial slots. The expansion plug is preas- sembled and is cylindrical in cross section.
2.3.2 Installation: Embedment, spacing, edge distance, and concrete requirements are shown in Tables 6'7 and 9. Holes must be predrilled in normal-weight or lightweight con- crete with carbide-tipped masonry drill bits manufactured within the range of the maximum and minimum drill tip dimen- sions of ANSI 821 2.15-1 994. The anchors must be installed in predrilled holes, the hole depth and diameter for each an- chor size being listed in Tables 6, 7 and 9. After the hole is drilled, it is cleared of all cuttings. The anchor is set by instal- ling the expansion shell and then driving the cone expander with a setting tool provided with each anchor size. When the
Ewbrnrion reports of ICBO Evduation Service, Inc., are issuedsoleIy to provide in formdon to elms A members of ICBO, utilizhg the code upon which the report
is based. Evaluation reports we not io beconstnred as representing wsthetics or any other amhtes not spedficdt~~ addressed norm an endorsement or recommen- dation for use of the subject report
This report b basedupon independent tests or other technical dam submined by the rqplicant. The IC30 EvdurrtiQn Service, Inc., technical athas revhedthe
tcsl results an#or other da@ but does notpossess Icstfeciiities to make M independent venicmh. There is no warranty bylC30 Evaluation Service, Inc, express
or implie4 as toany ~F~~ng"oroLermaU~innherepo~ornrloonyprnBuclcowredby,yhe repoa Thisdisclaimerincludes, butisnoilimitedto, merchantabiiity.
Page 1 of 7
. Page 2 'of 7 ER-1372
3.0
cone expander is driven down into the anchor, the legs of the
shell expand.
2.4 Design:
Allowable static loads are as set forth in Tables 1,3,6,9 and 10. Allowable loads for anchors subjected to combined shear and tension forces are determined by the following equation:
(P*/ Pp3 + ( v,/ V,)5/3 I; 1
where:
Ps = Applied service tension load.
Pt = Allowable service tension load.
V, = Applied service shear load.
V, = Allowable service shear load.
The anchors cannot be subjected to vibratory loads. Sources of such loads include, for example, reciprocating en- gines, crane loads and moving loads due to vehicles.
2.5 Special Inspection:
When special inspection is required, compliance with Section 1701 S.2 of the code is necessary. The special inspector must be on the jobsite continuously during anchor installation to
verify anchor type, anchor dimensions, concrete type, con- crete compressive strength, hole dimensions, anchor spac- ings, edge distances, slab thickness, anchor embedment and tightening torque.
2.6 Identification:
The concrete anchors are identified by their dimensional characteristics, the anchor size, and by the length code stamped on the anchor. The conical-shaped expander plugs are colored red. See Figure I for additional details. Length codes are in Table 8. Packages are identified with the anchor type and size, the manufacturer'sname and address, and the name of the quality control agency, PFS Corporation.
EVIDENCE SUBMllTED
Data complying with the ICBO ES Acceptance Criteria for Ex- pansion Anchors in Concrete and Masonry Elements (ACOI), dated January 1999.
4.0 FINDINGS
That the ITW RamsetlRed Head fasteners described in this report comply with the 1997 Uniform Building
CodeTu, subject to the following condltions:
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
Anchor sizes, dimensions and installation are as set forth in this report.
Allowable shear and tension loads are as set forth in Section 2.4.
Calculations justtfying that the applied loads com- ply with this report are submitted to the building of-
ficlal for approval.
Special inspection is provided as set forth in Sec- tion 2.5.
Anchors are limited to installation in uncracked concrete, which Is concrete subjected to tensile stresses not exceeding 170 psl (1.2 MPa) as in-
duced by external loads, deformations and interior exposures.
Anchors are limited to nonflre-reslstive construc- tion unless appropriate data is submitted to dem- onstrate anchor performance is maintained in fire- resistive situations.
Anchors are manufactured at Highway 12, Nlichi- gan City, Indiana, with Inspections by PFS Corpora- tion (NER--51).
Use of electroplated or mechanically plated carbon steel anchors is limited to dry, interior locations. Use of hot-dipped galvanized carbon steel is per- mitted in exterior-exposure or damp environments.
Except for ITW RamsetlRed Head Carbon Steel and Stainless Steel Trubolt Wedge anchors embedded in normal-weight concrete, as noted in Table 3, use of anchors in resisting earthquake or wind loads is beyond the scope of this report.
The anchors are not subjected to vibratory loads, such as those encountered by supports for ncip rocating engines, crane loads and moving loads due to vehicles.
This report is subject to re-examination In two years.
TABLE l--TTw RAMSETRED HEAD SELF-DRILLING ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pound~)~.s.~
EMBEDMENT
For SI: 1 inch = 25.4 mm, 1 Ibf = 4.45 N, 1 psi = 6.89 Wa.
'The tabulated shear andtensile values are for anchors installed in normal-weight concrete having thc designntrdultimate compressive strength atthe tinie of installation.
%eSe tension values are applicable only when the anchors are installed with special inspection as set forth in Section 2.5.
3The minimum concrete thickness is ll/z times the embedment depth, or the embedment depth plus three times the anchor diameter, whichever is grater.
4The anchors are illustrated as follows:
Values have been tabulated for both ASTM A 307 and A 449 bolts installed with the device.
6
. Page 3'of 7 ER-1372
TABLE Z-RECOMMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR ITW RAfflSETlRED HEAD SELF-DRILLING ANCHOR'
BOLT MAMETER (Inch)
114
318
I /2
314
DESCRIPTION
Hin. Allowable Min. Anow8bk Spaclng Bemeen Anchor5 (Inches) Edge Dlstance Edge Distance Re~uhad to (Inches) MIN. OWln Max. DIAMETER Working Load = 0.95 for Tenslon EMBEDMENT = 0.85 for Tention = 0.70 for Shear WoRlng Load = 0.75 lor Shear DEPM (Jnches) (Inch) (Inches)
Load F8sMr AppW R$iEPtO Load F8dl Applied Obtaln Max. ANCHOR
(inches)
'116 1 3/32 115116 I 3718 11-V16
9~~6 17/32 211/16 131~ 5318 21'116
"132 215/3t 43/8 ~ 231'~ 8"/16 43ig
"116 2'/32 39/16 1'31~~ 7'18 39f16
~ 1 3114 51'116 27/8 1 131~ 5"/16
For SI: 1 inch = 25.4 mni.
'Linear interpolation may be used for intermediate spacing and edge distances.
25 318
'12 55
TABLE MTW RAMSETRED HEAD TRUBOLT WEDGE ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)*,2.4~~6
~.~
11/2 420 210 580 560 280
2114 1,165 580 1,190 1,275 640
3 870 435 1,000 1,485 740 4 1200 600 1,485 740
4'18 1,165 580 1.810 2,410 1,205 6 1.335 665 2.410 1.205
I I I f',. 2000 OII I f'.. 4.000 Dd I
90 518
DIAMETER I
2314 1,645 820 1,780 1,795 900
7'12 1,765 880 3,755 1,880 5'18 1,645 820 2,400 3,730 1,865
TeMIon
565 280
I75 314
Tension
825 410 825 410
3'/4 1,780 890 2,530 2,710 1,355
10 2.145 1.375 4.470 2.235 65/8 2,745 1,375 5,080 4.425 2,210
250 718
1- 3314 2,380 1,190 3,290 3,685 1,840 all4 3,665 1,835 5,220 5,235 2,620 8 3,665 1,835 5,580 2,790
1 3,485 1,745 4,020 5,045 2,520 3,650 1,825 7,170 5,995 3,000 911, 4.675 2.340 6,635 3,315
300 4% 7318
I 11.4 500 5'12 4,535 2,270 5,820 6,595 3,300 8 6,835 3,413 8,770 10,825 5,410 10 9.035 4.515 11.385 5-695
shear lnspedlon
350 475
655 1,035 1,530 1,530
1,190 1.760 1,810 2,705 2.705
5;935 5;065 I 5,895
4,145 4,355
6.090
9,485 8,315
7,365 8,410 11.065 11,385 --I-- 14.075
Speclal
410 420 410
1,125 v 765
1,355 1,355
1,215 2,405
1,665 3,995 2,530 5.935 2,950
3,045
2,650 6,120 4,160 9,520 4,160 y 5,695 12,640
For SI: 1 inch = 25.4 mm, 1 psi = 6.89 Pa, 1 Ibf . A = 1.355 818 N. m, 1 Ibf = 4.45 N.
'The tabulated shear and tensile values are for anchors installed in stoneaggregate concrete having the desipatedultimate compressive strength at the time of installation.
2The holes are drilled with bits complying with ANSI B212.15-1994. The bit diameter equals the anchor diameter.
%ese tension values are applicable only when the anchors are installed with special inspection as set forth in Section 2.5.
'%e mininium concrete thickaess is l1/2 times the embedment depth, or the embedment depth plus three times the anchor diameter, whichever is greater.
5Allowable static loads may be increased one-third for earthquake or wind resistance in accordance with Section 1612.3.3 of the code. No fiuther increase is allowed
anchors are illustrated as follows: n
ER-1372 .Page 4of 7
For SI: 1 inch = 25.4 mm.
'Linear interpolation may be used for intermediate spacing and edge distances.
2Spacings and edge distances shall be divided by 0.75 when anchors are placed in structwal lightweight concrete in accordance with Table 10.
TABLE 5-RECOHMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR SHEAR LOADS FOR ITW RAMSETIRED HEAD TRUBOLT WEDGE ANCHORS'
For SI: 1 inch = 25.4 mm.
N/A = Not applicable.
'Linear interpolation may be used for intemiediate spacing and edge distances
2Spacings and edge distances shaU be divided by 0.75 when anchors are placed in structural lightweight concrete in accordance with Table 10.
Mln. Alloumble spadno lktmn Anchon (Inc-I Load Factor Applied - 0.40
2 J
+age 5'0f 7 ER-I 372
CODE
N 0 P s S T U V W X Y z
~ ~~____ ~~
TABLE MTW RAMSETIRED HEAD MULTI-SET II ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (po~nds)~~~~~.~
LENGTH
(Inches)
8 8'12 8'/2 < 9 9 < 9'12 9l/2 < 10 10< 11 11 < 12 12 < 13 13 < 14 14< 15 15 < 16 16 < 17 17 < 18 18 < 19
For SI: 1 inch = 25.4 mm, I lbf = 4.45 N, 1 psi = 6.89 kPa.
'The tabulatedshear and tensile values are for anchars installed in stone-aggregate concrete having the designatedultimate compressive strength at the time of installation.
*The holes are drilled with bits complying with ANSI B212.15-1994. ?lu bit diameter equals the anchor diameter.
3These tension values are applicable only when the anchors are installed with special inspection as set forth in Section 2.5.
4The minimmu concrete thickness is 1112 times the embedment depth, or the embedment depth plus three times the anchor diameter, whichever is greater.
'The anchors are illustrated as follows:
Values have been tabulated for both ASTM A 307 and A 449 bolts installed with the device.
TABLE 7-RECOMMENDED SPACING AND EDGE DISTANCE REQUIREMENTS FOR TTW RAMSEWRED HEAD MULTI-SET II ANCHOR'
Fa SI: I inch = 25.4 mm.
'bear interpolation may be used for intermediate spacing and edge distances.
'Spacings and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete in accordance with Table 9.
TABLE %-LENGTH IDENTIFICATION CODES
Black
Yellow
G purple
K NIA L NIA M NIA
LENofn OF ANCHOR
I lnvnl ..
38 51 51 < 63 63 < 76 76 < 89 89 < 102 102 < 114 114 127 127 < 140 140 < 152 152 < 165 I65 178 178 < 191 191 < 203
ANCHOR
lmml ..
203 < 216 216 < 229 229 < 241 241 < 254 254 < 267 267 < 305 305 < 330 330 < 366 366 < 38 1 381 <406 406 < 432 432 < 457 457 < 483
.
-
(inch)
I 12
8OLT DIAMETER
318
Page 6 of 7 ER-1372
LOWER FLUTE Of STEEL DECK WlTH LIGHTWEIGHT CONCRETE LIGHTWEIGHT CONCRETE FILL r; = 3.wo pd r; = l.m psi
MINIMUM TensIan Tenslon EMBEDMENT DEPTHS Wlth Special Without Speclal With Spcclai Without Sped81 ANCHOR DIAMETER (Inch) (ICheSp inrp.ctlon3 Inwctlon Shmr lnspectlon lnrpectlon Shear
51, 2 1,020 510 1,410 800 400 1,235
'12 1~116 965 482 1,105 835 41 7 1,105
TABLE MTW RAMSETIRED HEAD MULTI-SET II ANCHOR ALLOWABLE SHEAR AND TENSION VALUES pound^)',^.^ -
(inch)
I 12
8OLT DIAMETER
318
LOWER FLUTE Of STEEL DECK WlTH LIGHTWEIGHT CONCRETE LIGHTWEIGHT CONCRETE FILL r; = 3.wo pd r; = l.m psi
MINIMUM TensIan Tenslon EMBEDMENT DEPTHS Wlth Special Without Speclal With Spcclai Without Sped81 ANCHOR DIAMETER (Inch) (ICheSp inrp.ctlon3 Inwctlon Shmr lnspectlon lnrpectlon Shear
51, 2 1,020 510 1,410 800 400 1,235
'12 1~116 965 482 1,105 835 41 7 1,105
ANCHOR DIAMETER (Inch)
318
'12
sh
314
LOWER FLUTE OF STEEL DECK WH LIGHlWElGHT LIGHTWEIGHT CONCRETE COUCRETE FJLL
TeMbll Tenaion
r; = 1,000 PSI r; = 3.m psi
MlNlMUM
With Sped81 Without S cia1 INSTALL "tEYm$NT WLV,S~~~~P da, ~ TORWE (h-lb.) 0nCbS)J hspectlon inspcdk Shear 1n.pntlon Ins&" Shear
25 1'12 530 265 930 475 23 7 790 3 735 367 1,060 710 355 1 ,OOo
55 2l14 900 450 1,760 850 425 1,345 3 1,180 590 1,655 1,120 560 1,655 4 NIA NIA 1,730 1,200 600 1,610
90 3 1,500 750 2,310 1,180 590 1,375 5 1,490 745 2,320 1,645 822 2,285
5l14 2,225 1,112 3,980 1,760 880 NIA 175 3l/4 1,790 895 3,150 1,460 730 2,220
For Si: 1 inch = 25.4 mru, 1 Ibf = 4.45 N, 1 psi = 6.89 kPa.
'The tabulated shear and tensile values are for anchors installedin stmctural lightweight concrete having the designated ultimate compressive strength at the time ofinstal-
2The holes are drilled with bit< complying with ANSI B212.15-1994. The bit diameter equals the anchor diameter.
'These tension values are applicable only when the anchors are installed with special inspection as set forth in Section 2.5.
41nstallation details are in Figure 3. Spacing and edge distances are in Table 7 as rnodified by Footnote 2.
lation. Values have been tabulated for both ASTM A 307 and A 449 bolts installed with the device.
TABLE IO-ITW RAMSETIRED HEAD TRUBOLT WEDGE ANCHOR ALLOWABLE SHEAR AND TENSION VALUES (pounds)lqz4
For SI: 1 inch = 25.4 mm, 1 psi = 6.89 Ha, 1 Ibf = 4.45 N.
NIA = Not applicable.
'The tabulated shear and tensile values are for anchors installed in strud lightweight concrete having the designated compressive strength at the time of installation.
2The holes are drilled with bits complying with ANSI B212.15-1994. The bit diameter equals the anchor diameter.
3These tension values are applicable only when the anchors axe installed with special inspection as set forth in Section 2.5.
41nstallati0n details are in Figure 3. Spacing and edge distances are in Tables 4 and 5 as modified by Footnote 2.
I I Self-Drills Trubolt Wedge Anchors Multi-Set li
S bolt size) ws Carbon Steel anchor size x length) RM-Carbon Steel {bolt size)
I I
FIGURE IIDENTFICATION SYMBOLS FOR THE VARIOUS ANCHORS
*Page 7'0f 7 ER-1372
1 .oo
0.60
0.20
E2 El E
FIGURE 2-LOAD FACTORS FOR TRUBOLT WEDGE ANCHOR SHEAR LOADS AT REDUCED EDGE DISTANCES (See also Table 5)
1' CLR. UN.
\ - TRUBOLT
LIbH7WLIBM GoslERm ONLY
1
E DEPTH OF EMBEDMENT
For SI: 1 inch = 25.4 mm.
FIGURE GTRUBOLT AND MULTI-SET It ANCHORS IN LIGHTWEIGHT CONCRETE (f' = 3,000 psi) AND STEEL DECK WITH LIGHTWEIGHT CONCRETE FILL (f; = 3,000 psif
Lu Lh
d tl
x-
w
J
3" Q
10-23-2003
Job Address: Perm it Type: Parcel No:
Valuation: Reference #:
Project Title:
Applicant: TIM LUX
949 581-2255
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision
Building Inspection Request Line (760) 602-2725
Permit No: PCR03199
191 1 CALLE BARCELONA CBAD St: 150
PCR Status: ISSUED Lot#: 0 Applied: 0911 512003
Pian Approved: 1012312003 Issued: 1012312003
$0.00 Construction Type: NEW Entered By: RMA
TILLYS-ADD ROOF MOUNT EQUIPMEN Inspect Area:
& RE-ORGANIZE DATA ON REMAINING SHEETS
Owner:
Plan Check Revision Fee Additional Fees $1 80.00
$0.00
Total Fees: $1 80.00 Total Payments To Date: $0.00 Balance Due: $1 80.00
E34 10/23/03 0002 51 92
CGP 185 = 00
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO
EST. VAL.
Plan Ck. Deposit
Date
this address)
Legal Description Lot No. Subdivision NamelNumber Unit No. Phase No. Total # of units
Assessor's Parcel # Existing Use Proposed Use
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1$5001).
Name Address City Statelzip Telephone #
State License # License Class City Business License #
Designer Name Address City Statelzip Telephone
State License #
0 of the work for which this permit is issued.
0 issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100.000). in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0
1.
2.
3.
4.
number I contractors license number):
5.
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES UNO
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number / contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
Business and Professions Code for this reason:
of work):
PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
0 YES 0 NO
ON LmJDlNQ
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
9
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is c
APPLICANT'S SIGNATURE DATE y,//c/Q3 180 days (Section 106.4.4 Uniform Building Code).
V WHITE: File YELLOW: Applicant PINK: Finance
w
0
0
U
0
O
w
0
EsGil Corporation
In Bartnersfiip witfi Government for @uil&ng Safety
DATE:‘ 10/21/03
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 03-671.PCR03-199 SET: I1
PROJECT ADDRESS: 191 1 Calle Barcelona Suite 150
PROJECT NAME: Tilly’s - Revision to Structural For WAC
0 PLAN REVIEWER
0 FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: Fax #:
Mail Telephone ‘ Fax In Person
REMARKS:
By: Doug Moody Endiosu res:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 1 0/14/03 tmsrntl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 6 (858) 560-1468 + Fax (858) 560
EsGil - Corporation
In Partnership with Government for suifiring Safety
DATE: 9/27/03
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 03-671.PCR03-199 SET: I
PROJECT ADDRESS: 1911 Calle Barcelona Suite 150
PROJECT NAME: Tilly’s - Revision to Structural for WAC
0
CI
0
w
0
w
w
cl
0 PLAN REVIEWER
0 FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Tim Lux
6 Morgan Suite 11, Imine, CA 92618
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Tim Lux Telephone #: 949-581 -2255 C~JAVA/LA~*)
Date contacted: 9/29/03 (by: ) Fax #:(qqq) SB 3 * 12 b3
Mail Aelephone Fax4 In Person
REMARKS:
By: Doug Moody Enclosures:
Esgil Corporation 0 GA 0 MB EJ PC 9/18/03 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 03-67 1 .PCRO3- 199
9/27jo3
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 03-671.PCR03-199
OCCUPANCY: M USE: Retail
TYPE OF CONSTRUCTION: VN ACTUAL AREA: 9555sf
ALLOWABLE FLOOR AREA: STORIES:
JURISDICTION: City of Carlsbad
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 9/15/03
HEIGHT:
OCCUPANT LOAD: 245
.
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 9/18/03
DATE INITIAL PLAN REVIEW
COMPLETED: 9/27/03
PLAN REVIEWER: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation , noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification , modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a COPY) where each
correction item has been addressed, Le., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tifom.dot
EsGil - Corporation
In Partnership with Government for @uilding Safety
DATE: 10/21/03
JURISDICTION: City of Carlsbad 0 PLAN REVIEWER - 0 FILE
PLAN CHECK NO.: 03-671.PCRO3-199 SET: I1
PROJECT ADDRESS: 191 1 Calle Barcelona Suite 150
PROJECT NAME: Tilly’s - Revision to Structural For WAC
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
(7 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
u The check list transmitted herewith is for your information. The plans are being held at Esgil
and should be corrected and resubmitted for a complete recheck.
‘
Corporation until corrected plans are submitted for recheck.
0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
.I Person contacted: Telephone #:
Date contacted: (by: 1 Fax #:
Mail Telephone - Fax In Person 0 REMARKS:
By: Doug Moody Enclosures:
Esgil Corporation
GA MB EJ 0 PC 1 0/14/03 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 e San Diego, California 92123 e (858) 560-1468 Fax (858) 560
~~-
. City of Carlsbad 03-671.PCROS-199
9/27/03
Revision
I
VALUATION AND PLAN CHECK FEE
Reg. VALUE ($) :;g;ioe: Mod.
1
JURISDICTION: City of Carlsbad
199
PLAN CHECK NO.: 03-671.PCRO3-
PREPARED BY: Doug Moody DATE: 9/27/03
I Air Conditioning
Fire Sprinklers
I I I I I
TOTALVALUE I
Jurisdiction Code Icb By Ordinance I
1994 UBC Building Permit Fee
--__-____
zj 1994 UBC Plan Check Fee - -- __
Type of Review: Complete Review Structural Only
- u Repetitive Fee 7 Repeats
I
* Based on hourly rate
Comments:
0 Other
Hourly -1 Hours*
Esgil Plan Review Fee
I $1 80.001
Sheet 1 of 1
macvalue.doc
-..
PLANNING/ENGINEERING APPROVALS
RESIDENilAl
RESIDENTIAL ADDmON MDNOR PLAZA CAMIN0 REAL
(< $10,oao.ao, \
CARkSW COMPANY STORES
VlLLAGI FABRE
COMPLETE OFFICE BUtLDtNC
OTHER
PLANNER I DATE I I 17/43
Carlsbad Fire Department 031 99
1635 Faraday Ave. Fire Prevention
Y Carlsbad, CA 92008 (760) 602-4660
Plan Review Requirements Category: Building Plan
Date of Report: 10/01/2003 Reviewed by:
Name: DATUM ARCHITECTS
Address: 6 MORGAN SUITE 111
City, State: IRVINE CA 92618
Plan Checker: Job#: 03199
Job Name: Tilly's Bldg #: PCR03199
Job Address: 191 1 Calle Barcelona Ste. or Bldg. No. 150
C] Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2nd 3 rd Other Agency ID
FD Job # 03199 FD File #
. Carlsbad Fire Department 031 99
1635 Faraday Ave Fire Prevention
Carlsbad, CA.92008 (760) 602-4660 I
Plan Review
Date of Report: 10/01~003 Reviewed by:
Name: DATUM ARCHITECTS
Address: 6 MORGAN SUITE 11 1
City, State: IRVINE CA 92618
03199 Plan Checker:
Job Name: Tilly's
Job Address: 191 1 Calle Barcelona Ste. or Bldg. No. 150
Fire Department does not require the propsed Fire Alarm system be installed. It is strongly suggested
that the proposed Fire Alarm system be omitted. Local smoke detection is acceptable. Central
station monitoring is not required by either UFC or UBC. If applicant strongly desires to have installed
said alarm, plans must be submitted seperately.
STBJOBNO. 03- r3s STB STRUCTURAL ENGINEERS, INC.
PROJECT: 1 ccY'5 - 6-c 5mD BYBDATE: B -03
DATE: CLIENT: Qztrua SHEET NO.-, 0F.A
n
6 m'5
c t
/ 27
SUPPORT AT OPENING
1 3/4" x 14" 1.9E MicroIlamO LVL @ 24" olc
THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS
FOR THE APPLICATION AND LOADS LISTED
User 2 9/8/2003 2 53 46 PM
Page 1 Engine Version 1 6 44
Member Slope: On2 Roof SlopeOn2
~ ~~ -~
All dimensions are horizontal. L" Product Diagram is Conceptual.
LOADS:
Analysis is for a Joist Member.
Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 15.0 Dead
Vertical Loads:
TYW Class Live Dead Location Appllcatlon Comment
Uniform(plf) Roof(1.25) 0.0 12.5 16' TO 28' Adds TO
Point(1bs) Roof(1.25) 0 1092 1'6
Point(lbs) Roof(1.25) 0 212 2'2 318" -
SUPPORTS:
Input Bearing Vertical Reactions (Ib) Ply Depth Nailing Detail Other
Wldth Length LivelDeadlUpllfWTotaI Depth
1 Glulam or solid sawn lumber beam 6.75 Hanger 560 I 1703 IO I2263 1 14.00 NIA Top MountHanger None
2 Glulam or solid sawn lumber beam 6.75 Hanger 560 I 591 IO Ill51 1 14.00 NIA TopMountHanger None
HANGERS: Simpson Strona-Ti& Connectors
support Model Slope Skew Reverse Top Flange Top Flange Support Wood
Flanger, Offset Slope Speclea
1 Top Mount Hanger MIT1.81I14 0112 0 NIA
2 Top Mount Hanger ITT14 0112 0 NIA
-Nailing for Support 1: Face: 2-10dI Top 4-10d, Member: 2-N10
-Nailing for Support 2: Face: 2-NlO , Top 4-Nl0, Member: 2-N10
DESIGN CONTROLS:
Maximum Design Control Control
Shear (Ibs) 2224 1050 5819 Passed (18%)
Moment (Ft-Lbs) 7417 7417 15768 Passed (47%)
Live Load Defl (in) 0.635 0.896 Passed (USOS)
Total Load Defl (in) 1.332 1.344 Passed (U242)
-Deflection Criteria: MlNlMUM(LL:U360,TL:L/240).
No 0 Douglas Fir
No 0 Douglas Fir
Location
Lt. end Span 1 under Roof loading
MID Span 1 under Roof loading
MID Span 1 under Roof loading
MID Span 1 under Roof loading
-Allowable moment was increased for repetitive member usage.
-Bracing(Lu): All compression edges (top and bottom) must be braced at 2' 8 OIC unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve
member stability.
ADDITIONAL NOTES:
-IMPORTANT! The analysis presented is output from software developed by TNS Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application. input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Associate.
-Not all products are readily available. Check with your supplier or TJ technical representative for product availability.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY!
-Allowable Stress Design methodology was used for Building Code UBC analyzing the TJ Custom product listed above.
PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
PROJECT INFORMATION:
03-135
TILLY'S- CARLSBAD
OPERATOR INFORMATION:
Ramon Sanchez
STB Structural Engineers, Inc.
21084 Bake Parkway Suite 100
Lake Forest. CA 92630
Phone : 949-599-0320
Fax : 949-599-0325
Copyright .' 2003 by Trus Joist, a Weyerhaeuser Business Hisrollamx is a registered trademark of Trus Joist.
Simpson Strong-Tie6 Connectors is a registered trademark of Simpson Strong-Tle Company, Inc.
J:\03-135\microlam.sms
STB STRUCTURAL ENGINEERS, INC. STBJOBNO. O3-
STB STRUCTURAL ENGINEERS, INC. STB JOB NO. 03-' 35
RSS BY: - DATE: PROJECT: TILLY'S CARLSBAD
DATE: CLIENT: DATUM SHEETNO. 5 OF 0
I II II II II II
I1 I
.I I I
II II I1O0 88 0 0 1100 0~;oOo
0 0 00 [ II Ill II I I jj I II II
II II II II
I; 0000 11 0 0 1; 00 11 00000
I II 0 II II 00000
I II II 11
II I II
I jj I I ij I I!
II II II II
I1 I
II II II II
$0000 11 0000 I1 0000 I1 00000 I1
I 0 0 0 II 00000 I:
I
I
I
I
I
I
II II II II II
00
II
nnYZ zzww
nann wwww -1-1-1-1 naaa naaa <<<a
II II
00
**
O II
II
STB JOB NO. 5 STB STRUCTURAL ENGINEERS, INC.
RSS BY: - DATE: - PRO JEcT: TILLY'S CARLSBAD -
DAT, DATE: CLIENT: DATUM SHEETNO. b OF-4
II I
I1 I II II I
88 8 8 0080 O
0 J5i
0 0
8 02
0 Ill
.I I I II
J 0 8s 00 888 000
0
I1 I II
0 0
3
9.
. Ill
.I I I
80990 0 00 88 8 8 0080 0 88 00
3
888 000
0 99999999 0 0 0 0 0 0 0 0 - 0 JS I
II I II I
0 B -
II
11
II
Ill
II I I1 I
$85 000
0 0 2%
6
m, $j ln a< cd
'I i i 11
9 8Fz
6" gii 4 ii Ill
I1
99999999 00000000
O II 0
ti II : II
E
i .c .5 .5 .- c E.E .E .c .. ..
c .- c
STB STRUCTURAL, ENGINEERS, INC. STB JOB NO. 03- 65-
PROJECT: lucY '5 - Cmsmn BY:@% DATE: ?/ 03
DATE: CLIENT: V&==mt SHEETNO. 2 OF.7
r
I
-4 --o
/ -G
--@
I
I
I 1
4
i i
3 r f ..
, . I..
1 1-1 8-2003
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision
Building Inspection Request Line (760) 602-2725
Permit No: PCR03250
Job Address:
Permit Type: PCR Status: ISSUED
Parcel No: Lot#: 0 Applied: 10l2912003
Valuation: $0.00 Construction Type: NEW Entered By: SB Reference #: CB030671 Plan Approved: 11/18/2003 Issued: 11/18/2003
Project Title: TILLYS DEFERRED SUBMITAL Inspect Area:
191 1 CALLE BARCELONA CBAD St: 150
BACKROOM STORAGE SHELVING
Applicant:
ARNElT CONSTRUCTION
SUITE # 108 401 0 MORENA BLVD 921 17
858-270-4792
Owner:
Plan Check Revision Fee
Additional Fees
$1 20.00
$0.00
Total Fees: $120.00 Total Payments To Date: $0.00 Balance Due: $120.00
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
.J 1 Address (include BldgISuite #) Business Name
FOR OFFICE USE ONLY
PLAN CHECK NO.&ZCa
EST. VAL.
Validated By
(ZL 4//s
(at this address)
Legal Description Lot No. Subdivision NamelNumber . Unit No. Phase No. Total # of units
JdBm Id72 L 06 -3 /-ab -= 12.4 a%4LSwAP? (Sp3&& - Sc/ELV//&
Proposed Use Existing Use
# of Bathrooms SO. FT. #of Stories # of Bedrooms
Name Address City StatelZip Telephone #
ER
Name Address city StatelZip Telephone #
(Sec. 7031.5 Business a
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001).
Name Address City StatelZip Telephone #
State License I License Class City Business License #
Designer Name Address city StatelZip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 of the work for which this permit is issued.
0
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ~$100,000). in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
SIGNATURE DATE
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
0
1.
2.
3.
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES UNO
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
Business and Professions Code for this reason:
4.
number I contractors license number):
5.
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
of work):
PROPERTY OWNER SIGNATURE DATE
SECTIO
r future
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
0 YES 0 NO
DIN
affirm ac
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit IS suspended or abandoned
at any time after the work is commenced for
APPLICANT'S SIGNAT DATE /d- 29 -
~~
EsGil Corporation
In partnership with Government for suiting safety
DATE: 11/10/03
JURISDICTION: City of Carlsbad WT 0 PLAN REVIEWER - 0 FILE
PLAN CHECK NO.: 03-671 rev(PCR03250) SET: I
PROJECT ADDRESS: 1911 Calle Barcelona Suite 150
PROJECT NAME: Storage Fixture for Tilly’s
0 The plans transmitted herewith have been corrected where necessary and substantialfy comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
-,
and should be corrected and resubmitted for a complete recheck.
[3 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant
[3 The applicant’s copy of the check list has been sent to:
contact person.
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted : Telephone #:
Date contacted: (by: ) Fax #:
REMARKS: Fire Department approval is required.
Mail Telephone Fax In Person
By: DavidYao Enclosures: original approved plan
Esgil Corporation
0 GA 0 MB 0 EJ 0 PC 1113 tmsmtl.dot
,
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
City of Carlsbad 03-671 rev(PCR03250)
11/ 10/03
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
rev(PCR03250)
PLAN CHECK NO.: 03-671
PREPARED BY: David Yao DATE: 11/10/03
BUILDING ADDRESS: 1911 Calle Barcelona Suite 150
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
Blda Permit Fee by Ordinance V I
Plan Check Fee by Ordinance -* I
Type of Review: 0 Complete Review 0 Structural Only
Repetitive Fee Repeats
0 Other
Hourly I ~ 11 Hour*
I Esgil Plan Revlew Fee
1 $1 20.001
I $96.00 I
Based on hourly rate
Comments:
Sheet 1 of I
rnacvalue.doc
Carlgbad Fire Department 03250
1635 Faraday Ave.
Carlsbad, CA 92008
Fire Prevention
(760) 602-4660
Plan Review Requirements Category: High Piled Combustible
Date of Report: 11/17/2003 Reviewed by:
Name: Eugene Arriola
Address: 10 Whatney
City, State: lrvine CA 92618
I
Plan Checker: Job#: 03250
Job Name: Tilly's Bldg #: PCR03250
Job Address: 191 1 Calle Barcelona Ste. or Bldg. No.
0 Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2 nd 3rd Other Agency ID
FDJob# 03250 FD File #
.Carlsbad Fire Department 03250
. Carlsbad, CA 92008
1635 Faraday Ave. Fire Prevention
(760) 602-4660
Plan Review
Date of Report: 1 1/17/2003 Reviewed by:
Name: Eugene Arriola
Address: 10 Whatney
City, State: Imine CA 92618
Plan Checker:
Job Name: Tilly’s
03250
Job Address: 191 1 Calle Barcelona Ste. or Bldg. No.
See specific note.
Requirements Category: High Piled Combustible Storage
~ r Requirement: Pending 15.17 Additional requirements or comments
A RENEWABLE STORAGE PERMIT SHALL BE REQUIRED TO BE OBTAINED AT/ OR PRIOR TO
FINAL INSPECTION. PLEASE CONTACT CARLSBAD FIRE DEPARTMENT AT 760-602-4666 TO
OBTAIN PERMlTlNG INFORMATION.
Page 1 1 1 /I 7/03
SElZMlC
MATERIAL HANDLING ENGINEERING
EST. 1985
STORAGE RACKS STEEL SHELVING SEISMIC ANALYSIS ALASKA INDIANA OHK)
DRIVE-IN RACKS MOVABLE SHELVING STRUCTURAL DESIGN ARIZONA
CANTILEVER RACKS STORAGE TANKS CITY APPROVALS CALIFORNIA MICHIGAN Cfmm
MEZZANINES MODULAR OFFICES STATE APPROVALS mm MINNESOTA PENNSYLVANIA
CONVEYORS GONDOLAS PRODUCT TESTING CONNECTICUT MISSOURI TEXAS
CAROUSELS BOOKSTACKS FIELD INSPECTION G!B=K34 MONTANA UTAH
PUSHBACK RACKS FLOW RACKS SPECIAL FABRICATION IDAHO NEVADA VIRGINIA
RACK BUILDINGS FOOTINGS PERMITTING SERVICES ILLINOIS NEW MEXICO WASHINGTON
OKLAHOMA KANSAS
LIGHT DUTY STORAGE FIXTURES
TILLY'S
191 1 CALLE BARCELONA STE 150
CARLSBAD, CA
JOB 8~03-1441
161 ATLANTIC STREET POMONA CA 917 ._ FILE COPY
PROJECT TILLY'S
mR TILLY'S
SHEET NO. 2 OF 10
CALCULATEDBY J.J. DATE 10121 /03
SEIZMIC @
MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0969 FAX: (909) 869-0981
161 ATIANTIC AVENUE POMONA CA 91768
LIGHT DUTY STORAGE FIXTURES:
PROJECT SCOPE
THE PURPOSE OF THIS ANALYSIS IS TO SHOW THAT THE FOLLOWING LIGHT DUTY STORAGE SYSTEM
COMPLIES WITH SECTION 1630.2.1 OF THE 2001 CBC/l997 UBC.
CRITICAL CONFIGURATION ANALYZED.
PARAMETERS
SHELVING UNITS WILL BE ANALYZED AS AN ELEMENT UTILIZING THE FOLLOWING
FOR MU LA:
V= 2.5xCaxIxW/R
WHERE:
Ca = 0.44
I= 1.0
R = 5.6 <== FOR MOMENT FRAMES
1.4 <=== WORKING STRESS REDUCTION
W= LUn+DL
n= 1
SPECIFICATIONS
STEEL - Fy = 36000 PSI
BOLTS - A307 UNLESS OTHERWISE NOTED
ANCHORS - 1/4"0 x 2" MIN. EMBED. HILT1 KWlK BOLT II ICBO 4627 (I.C.B.O. 4627)
SHELVES - PARTICLE BOARD OR PLYWOOD
SLAB - 5 IN x 3000 PSI
SOIL - 1,000 PSF
CON FIG U R AT1 ON S
CRITICAL CONFIGURATION ANALYZED
MATERIAL HANDLTNG ENGINEERING
TEL: (909) 869-0969 FAX: (909) 869-0981
PROJECT TILLY'S
FOR TILLY'S
CALCULATED BY J.J. DATE 10121 /03
SHEET NO. 3 OF 10
I /,t ~ ~
NOTE: THIS IS THE TRIBUTARY SYSTEM BEING ANALYZED.
PROJECT TILLY'S
m TILLY'S
SHEET NO. 4 OF 10
CALCULATEDBY J.J. DATE 10/21/03
SElZMlC @
MATERIAL HANDLING ENGINEERING
TEL: (909) 8694989 FAX: (909) 869-0981
STRESS= 45%
STRESS = 48%
#RIVETS= 2
161 ATLANTIC AVENUE POMONA CA 91768
I.C.B.O. # 4627
QUANTITY/(F.P.)= 1
SIZE= 1/4"0 x 2" MIN. EMBED.
SPECIFICATION TYPICAL FIXTURE
THE SUPPORT STRUCTURE SHALL BE ANALYZED WITH RESPECT TO THE REQUIREMENTS SET FORTH
IN THE 2001 CBC/l997 UBC. THE STRUCTURAL COMPONENTS SHALL BE ANALYZED
WITH RESPECT TO THE MOST CRITICAL CONFIGURATIONS OF LOADS RESULTING FROM STATIC AND
RIVET SIZE= 1/41N
STRESS= 52%
LATERAL FORCES.
COLUMN STEEL- 36,000 PSI
BEAM STEEL- 36,000 PSI
BASE STEEL- 36,000 PSI
BOLTS- A307 UNLESS OTHERWISE NOTED
SLAB- 5 IN * 3000 PSI
SOIL- 1000 PSF
SEISMIC FORMULA- 2.5 x Ca x I x W / R
STRESS (FULL)= 9%
STRESS (TOP)= 2%
SLAB AND SOIL
SLAB THICK= 5.0 IN
CONCRETE f'C= 3,000 PSI
SOIL BEARING= 1,000 PSF
STRESS(PUNCTURE)= 21 %
STRESS(TENSION)= 13%
(SECTION 1630.2.1 OF THE 2001 CBCll997 UBC)
SEISMIC ZONE 4
Na= 1*0
CONFIGURATION
SINGLE ROW UNITS
# LEVELS= 6 LVL
BEAM LENGTH= 72.0 IN
LULEVEL= 250 LB
DUL-EVEL= 20 LB
t FRONT VIEW 72" SIDE VIEW 24" I
3"
SUMMARY OF RESULTS (TYPICAL FIXTURE)
I BEAM I COLUMN I ANCHORS (OVERTURNING) I I TYPE=APHlO 1 TYPE= HILT1 KWlK BOLT II I TYPE= DRB I
PROJECT TILLY'S
Fa? TILLY'S
SHEET NO. 5 OF 10
CALCULATED BY J.J. DATE 10/21/03
SElZMlC a MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0989 FAX: (909) 869-0981
1 SEISMIC SHEAR
161 ATLANTIC AVENUE POMONA CA 91768
LOADS & DISTRIBUTION: TYPICAL FIXTURE
wx hx
81 0
7,560
12,960
19,710
24,300
30,510
RACK ANALYSIS WILL BE BASED ON SECTION 1630.2.1 OF THE 2001 CBCl1997 UBC, WHERE SEISMIC SHEAR IS
DERIVED AS:
V= 2.5xCaxIxWIR
Fi
1.9 LB
17.9 LB
30.7 LB
46.7 LB
57.6 LB
72.4 LB
Ca = 0.44
I= 1
R = 5.6
n= 1
1.4
95,850
#of SHELF LVLS = 6
SHELF LL = 250 LBlLVL
DULEVEL = 20 LBlLVL
TOTAL LL = 1,500 LB
TOTAL DL = 120 LB
227 LB
e== MOMENT FRAMES
<=== WORKING STRESS REDUCTION
V = 2.5 x 0.44 x 1 x (1500 LB l 1 + 120 LB) l 5.6 x 1.4
= 227 LB
LEVEL
1
2
3
4
5
6
wx(DL + LL)
270 LB
270 LB
270 LB
270 LB
270 LB
270 LB
1,620 LB
hx
3.0000 IN
28.0000 IN
48.0000 IN
73.0000 IN
90.0000 IN
113.0000 IN
TOTAL =
I I
502 IN-LB
1,475 IN-LB
3,412 IN-LB
5,186 IN-LB
8,176 IN-LB 1
PROJECT TILLY'S
FQR TILLY'S
SHEET NO. 6 OF 10
MATERIAL HANDLING ENGINEERING CALCULATEDBY J.J. DATE 10/2 1/03 TEL: (909) 869-0989 FAX: (909) 869-0981
161 ATLANTIC AVENUE POMONA CA 91768
TRANSVERSE ANALYSIS: TYPICAL FIXTURE
COLUMN FORCES
Mbase = 0 IN-LB
PcoKseisrnic) = Movt/d
= 782 LB
VCOI=V/~= 114LB
Mcol(1-1) = Vcol x hi - Mbase
= 114 LB x 3 IN - 0 IN-LB
= 341 IN-LB
Mcol(2-2) = [Vcol - SFi121 x hi12
= [114 - 11 LB x 25 IN 12
= 1,409 IN-LB
McoI(3-3) = 1,037 IN-LB
McoI(5-5) = 552 IN-LB
Mcol(6-6) = 416 IN-LB
BEAM TO COLUMN MOMENTS
Mconn(1-1) = [Mcol(l-l) + Mcol(2-2)l 1 2
Mconn(2-2) = 1,223 IN-LB
Mconn(3-3) = 1,071 IN-LB
= 875 IN-LB
<==BASE ASSUMED TO BE PINNED
PCOl(1-1) = 810 LB
PcoI(2-2) = 67.5 LB <== COLUMN CHECK
PcoI(3-3) = 540 LB
Pcol(5-5) = 405 LB
PcoI(6-6) = 270 LB
c== CONNECTION CHECK
PROJECT TILLY'S
FOR TILLY'S
SHEET NO. 7 OF 10
MATERIAL HANDLING ENGINEERING CALCULATED BY J.J. DATE 10/21/03 TEL: (909) 669-0989 FAX: (909) 869-0981
161 ATLANTIC AVENUE POMONA CA 91 768
COLUMN ANALYSIS: (APH10) TYPICAL FIXTURE
ANALYZED PER THE 2001 CBC/1997 UBC. SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION.
Ptotak 1,457 LB
Mmax= 1,409 IN-LB
KXLX~X = 1.2*25.5 lN10.6365 IN
= 48.1 e=== (Kl1r)rnax
= 37.7
KyLylry = 1.2*25.5 IN10.811 IN
AXIAL
Fe= xA2E/(KUr)maxA2
= 126.0 KSI
Fy12= 18.0 KSI
SINCE, Fe > Fy12
THEN, Fn= Fyll -Fy/4Fe)
= 36 KSI*[1-36 KS11(4*126 KSI)]
= 33.4 KSI
Pn= Aeff*Fn
= 13,137 LB
Qc= 1.92
Pa= PnlSlc
= 131 37 LB11.92
= 6,842 LB
P/Pa= 0.21 > 0.15
,FLEXURE
CHECK: P/Pa + (Crnx*Mx)/(Max*px) 5 1.33
P/Pao + MxlMax 2 1.33
Pno= Ae*Fy
= 0.393 IN"2 *36000 PSI
= 14,148 LB
Pao= PnolSlc
= 141 48 LBll.92
= 7,369 LB
Myield=My= Sy*Fy
= 0.138 IN"3 * 36000 PSI
= 4,972 IN-LB
Max= MylQf
= 4972 IN-LB11.67
= 2,977 IN-LB
Pcr= xA2EIl(KL)maxA2
= ~"2*29500000 PSI/(1.2*25.5 IN)^:
= 49,601 LB
THUS,
SECTION PROPERTIES
t = 0.075 IN
Aeff = 0.393 IN"2
IX = 0.160 IN"4
SX = 0.116 IN"3
TX = 0.637 IN
ly = 0.259 IN"4
Sy= 0.138 IN"3
ry = 0.811 IN
Kx= 1.2
Lx = 25.5 IN
Ky= 1.2
Ly = 25.5 IN
Fy= 36 KSI
E= 29,500 KSI
Of= 1.67
Crnx= 0.85
Cb= 1.0
px= {1/[1 -(Szc*P/P~r)l}~-l
= {1/[1-(1.92*1457 LB/49601 LB)]}"-l
= 0.94
(1 457 LB16842 LB) + (0.85*1409 IN-LB)/(2977 IN-LB*0.94) =
(1457 LB17369 LB) + (1409 IN-LB12977 IN-LB) =
0.64 c 1.33, OK
0.67 < 1.33, OK
PROJECT TILLY'S
FOR TILLY'S
SHEET NO. a OF 10
MATERIAL HANDLING ENGINEERING CALCULATED BY J.J. DATE 1 012 1 /03 TEL: (909) 869-0989 FAX: (909) 669-0981
= (1.88LB/IN)*(72 IN)"2/8
= 1,215 IN-LB
fb/Fb = M/(S x Fb)
= 1215/(0.125 1N"3*0.6*36000 PSI)
161 ATLANTIC AVENUE POMONA CA 91 768
/
/
/
' t=l4 ga.
/
DOUBLE RIVET BEAM (DRB) ANALYSIS: TYPICAL FIXTURE
ALTHOUGH CONNECTIONS PROVIDE SOME FIXITY, THE BEAM WILL BE ANALYZED AS A SIMPLE
SUPPORTED BEAM. NOTE THAT ANALYSIS WILL BE BASED ON MAXIMUM LOAD PER BEAM.
LOADEHELF = 270 LB
LOADSHELF W = LOAD/2 BEAMS
LOAD/BEAM w = W/2L
= (250 LB+20 LB)/(2*72 IN)
2 11/16" 1
CONNECTION ANALYSIS: TYPICAL FIXTURE
Mconn. = (Mupper + Mlower)
=
= 1,223 IN-LB
(M 7-1 + M 2-2)/2
a) SHEAR CAPACITY OF 1/4"0 RIVET
A= ((DIA.IA2)n/4
= .0491 IN"2
Pmax = Fy x Area
= 1178LB Ml-14
Mconn.allow= Pmax x d x 1.33 d (CTR TO CTR SPACING) = 1.5 IN
RIVET DIA. = .25 IN = 2,356 IN-LB
Mconn / Mconn allow = 0.52 e 1.00 O.K. COLUMN THK. = .0747 IN
RIVET (Fy) = 24,000 PSI
PROJECT TILLY'S
TILLY'S FOR SEIZMIC
SHEET NO. 9 OF 10
CALCULATEDBY J.J. DATE 10/21/03
-*
MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0989 FAX: (909) 869-0981
161 ATLANTIC AVENUE POMONA CA 91 768
OVERTURNING ANALYSIS: TYPICAL FIXTURE
EL n DEPTH = 24.0 in
TOP LEVEL HEIGHT = 120 in
FULLY LOADED:
Total Shear= 227 Ib EL 5
Mot = C(Fi*hi) * 1.15
= 21,570 in-lb
= (1620 Ib + 120 lb)*24 in/2
= 20,880 in-lb
MSt = C(Wp+wDL)*D/2 EL 4
Puplift = 1 (Mot - Mst)(Depth EL 3
= (21 570-20880)/24
= 29. Ib <= UPLIFT EL2
TOP SHELF LOADED:
SHEAR = 38 Ib
Mot = VtOp * ht * 1.1 5 EL 1
= 38Ib*120in*1.15
= 5,228 in-lb I I/
Mst = (Wp+wDL)*D/2 A
= (250 Ib + 120 lb)*24/2
= 4,440 in-lb
Puplift = 1 (Mot - Mst)/Depth
= 33 Ib <= UPLIFT
FLOOR ANCHORS:
QUANTITY= 1
PULLOUT = 353 LB
SHEAR = 533 LB
COMBINED STRESS1 = (29 LB/353 LB)"5/3 + (1 14 LB/533 LB)"5/3
= 0.09 e1.0 OK
COMBINED STRESS2 = (33 LB/353 LB)"5/3 + (19 LB/533 LB)"5/3
= 0.02 1.0 OK
USE (1) 1/40 x 2" MIN. EMBED. HILT1 KWlK BOLT II (I.C.B.O. #4627) OR APPROVED EQUAL
PULL OUT CAPACITY IS THAT OF WITHOUT SPECIAL INSPECTION.
WALL ANCHORS:
AlTACH REAR POSTS TO CONTINUOUS 1 X6 WOOD FURRING AT 3" FROM FLOOR, 60" FROM
FLOOR & 96" FROM FLOOR. USE (1) #8 SELF TAPPING SCREWS.
WALL ADEQUACY:
ANALYZED TO COMPLY TO SECTION 161 1.5 OF THE 1997 UBC.
Wall(Ht) = 10.0 FT
Trib(Width) = 6.0 FT
Fp = 3.79 PSF e 5 PSF O.K.
PER SECTION 161 1.5 INTERlORlPARTlTlON WALLS > THAN 6 FT IN HEIGHT MUST BE DESIGNED FOR A MINIMUM OF
5 PSF LATERAL LOADING.
PROJECT TILLY'S
m TILLY'S
SHEET NO. 10 OF 10
CALCULATED BY J.J. DATE 10/21/03
SEIZMIC @
MATERIAL HANDLING ENGINEERING
TEL: (909) 869-0989 FAX: (909) 869-0981
= [(5.25 IN + 92) + (2.5 IN + 5 1N/2)1*(2)*(5 IN)
= 127.5 IN"2 7L b ,'
161 ATLANTIC AVENUE POMbNA CA 91768
2
L B /
/
BASE PLATE
Weff. = 5.25 IN
Deff. = 2.5 IN
I L /
CONCRETE
t = 5.0 IN
f'c = 3,000 PSI
Y
8 x .-
8,
A-
3
3-