Loading...
HomeMy WebLinkAbout1911 CALLE BARCELONA; 154; CB080979; Permit07-17-2008 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB080979 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title Applicant MARY RYAN P 0 BOX 3749 92690 949 582-3735 1911 CALLE BARCELONA CBADSt 154 Tl Sub Type 2550120400 Lot* $133 350 00 Construction Type Reference # PAPER SOURCE-3810 SF RETAIL TO RETAIL COMM 0 NEW Status ISSUED Applied 05/27/2008 Lntered By RMA Plan Approved 07/15/2008 Issued 07/15/2008 Inspect Area PY Plan Check* Owner BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L C/O DELOITTE TAX LLP PO BOX 131071 CARLSBAD CA 92013 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add I Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add I Pot Water Con Fee Reel Water Con Fee $71049 Meter Size $0 00 Add'l Reel Water Con Fee $461 82 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $2800 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $0 00 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TO PAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $7600 $3500 $2600 $000 $000 $000 $000 7? $1 337 31 Total Fees $1,33731 Total F'ayments To Date $1,33731 Balance Due $000 BUILDING PLANS JS/L IN STORAGE ATTACHED FINAL APPROVAL Inspector Date LAPm Clearance NOTICE Please take NOTICE Ih6t approval of your project includes the Imposition of fees dedications reservations or olher exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection witn this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise exoired City of Carlsbad 1635 Faraday Ave Carlsbad CA 92008 760 602 2717 / 2718 / 2719/ 2721 Fax 7606028558 Building Permit Application Plan Check No . 67 7 //) D [JOB DESCRIPTION OF WORK FEN ANT BUSINESS NAME CONSTR TYPE I OCC GROUP -1 £»F- &TC . EXISTING USE CONTACT NAME APPLICANT NAME ADDRESS CITY PHONE £EHTYOWERN»ME CONTRACTOR BUS NAME 12_ADDRESS ARCH/DC5JGNERN4ME& ADDRESS (V Ml i tutiMii ud htlaiim Cftdt An]r Gly » Cunly vhidl nnnm I pennt u cmmcl, llur. mwgn jimbfl cr npiir an ipwturt pnir lo ID uiirct. lha n^arti It* uoliunl br tudi acini II file 1 Iffiid lUltmtfil llill ht K hunlil lunom n At pnnun ol ihi CnrnDri linnc In (OvpTif» oi™»nita[ Mh baia (COO ol Dmin 1 ilpit liiinn ral tntiiau Cidi) tr itJl h! « luiipi dunlin, vd dit k*» br Hit iltfldT«n»«on Hq nlUM ot Sicncn 70JI j (7 «r ipftui" Ix ) pm>i lut|iai Ihe ippbcinl 10 i ami poilqr d noi ran dim in hunind hlbn (ISM)) Wortwrt CMnpenufioA Dadirjtkm I h^yafimundarp(^yalpajuTy me tflhafoBawmg declarations t hive ind will maintain * eerUfkata of consant to i«lf Insura for wotkers compensation as provided by Section 3700 of the Labor Code for Ihe performance of lha woik for whch Ihi3 permit s issued 1 have end will maintain worXen compenutfon as required by Section 3700 of the Labor Code for Ihe perfrxmanoa of Ihe workfor which this permit is issued My workers compensation insurance earner and polcy number arc Insi^Co SvlftTC pLglJD . PolcyNo Q&V &^t*7 " 7&0~f &a»t»»nrti ^^I-Q^ Th 19 section need not be completed rf Ihe permit 0 for one hundrod dollars (S100} or teas Certificate of Exemption 1 certify that in the perform nee of the work for which this permit is issued I shall not employ any person in any m inner so as to become subject (o Ihe Workers ComponsaUon Laws of Gdrfomia WARNING Failure to awareworkeri comDetiutloncoverage l>unlawful and ihiH autyoct tnonvloyerb>cririnal pnalta^ In addition to the coit of comrxniation. damaoejai provided JoAjiSiiUonfflffl the^bor cod* Intarett and attorney • fees M$ CONTRAaOR SIGNATURE ^/^j^. /&r&%fr4f DATt J - / <^~~ Q g I hereby affinn M? I am exempt from Contractor's License I aw for the following reason t as owner of the property or my employees with wages as their sole compensation will do (he work and the Structure s not mended or offered for sale (Sec 7044 Business and Professions Code The Contractor's License Law does no) apply to an owner of property who burkta or improves thereon and wno does such work himself 01 through his own eriployees provided that such •nprovements are not ntendsd or offered for sale If however the building or improvement is sold within one year ot completion the owrat bidder wil have the burden of proving that he dd not buld or improve for the purpose of sale) I as owner of the property am exduswery contracting with licensed contractors to const/uct Ihe project (Sec 7044 Business and Professors Code The Contractor's bcense Law does not apply to an owner of property who burids 01 improvos thereon and contracts (or such protects wilh contractors) licensed pursuant to the Contractor's License Lav) I am exempt under Sector) Buamass and Professions Code for this mason 1 I personalty plan to provrie the major labor and materials for conslucUxi of lha proposed property improvement Yes No 3 I have contracted with Ihe loOowng person (fan) to provide the proposed conslnxtron (include name address / phone / contractors license number) 4 I plan lo provide portcra of the work but I hem hired the following person to coordinate supervise and provde the major work (include nwme/ address/ phone /contractors I Dense number) 5 I wil provide some of Ihe work but I hwe contracted (hired) the Wtowing persons to provide Ihe work indcaled(iriduxle name /addreis/ phone J type of work) PROPERTY OWNER SIGNATURE DATE **£. Is the applicant or future building occupant requited lo subrr.rl a business plan acutely hazardous materials registration form or nsk management aid prevention program under Sections 25505 25533 cr 25634 ol the Presley Tanner Hazardous Substance Account Act? Yes No Is the applicant or future bidding occupant required to obtain a permit from the air pollution control dstnct or air Quality management district? Yes No Is the lact'ity lo be constructed wrthm 1 000 feet of the outer boundary of a school site7 Yes No IF ANY OF THE ANSWERS ARE YES, A RNAL CEDTIFICATE OF OCCUPAN" EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 1 hereby afTmttiat them is a construction lending agency for the perfbimanca of the work this permit is issued (Sec 3097 (i) Civil Code] Undei'sNanw Lender's Address ^ I hereby aultatzaropnajnMwolttwCfyofCato^ MXNHF1 AND KEffHflRWHSS THE CITY OF CARLSBAD OSHA AnOSHApenntisrequ^for«i(cawBboMQv«5X7<^(nldeRnilicinvoQ(Ukuclxma(xb^^ EXPIRATION EwpenittisMdbylheBuildiigOlltaluiiderteprcvisiiiHrf 180 days torn fte data of sudi p«nntor t too buttng or wuk wtfnnzed by ajch permit 13 suspended or etaidonodatarr/lrodteltovatBainriBrKrifaaperodof 1Wday5[Seclm1^ f~)DATI City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Lite Cife1 Plan Check # Permit# CB080979 Project Name PAPER SOURCE 3810 SF RETAIL TO RETAIL 1911 CALLE BARCELONA #154 Lot Phone 6199942767 Water Dist O Address Contact Person MARK Sewer Dist LC Date 08/21/2008 Permit Type Tl Sub Type COMM 0 Inspecte By _ Inspected By Date Inspected ol n 1$*% Approved Inspected By Date Inspected Date Inspected Approved Approved Disapproved Disapproved Disapproved Comments City of Carlsbad Bldg Inspection Request For 08/21/2008 Permit* CB080979 Title PAPER SOURCE-3810 SF RETAIL TO Description RETAIL Inspector Assignment PY Type Tl Job Address Suite Location APPLICANT MARY RYAN Owner Remarks Sub Type COMM 1911 CALLE BARCELONA 154 Lot 0 Phone 6199942767 Inspec tor Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By MARK Entered By CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments 08/08/2008 14 Frame/Steel/Boltmg/Welding AP PY 08/08/2008 17 Interior Lath/Drywall AP PY 07/23/2008 21 Underground/Under Floor CA PD 07/23/2008 24 Rougti/Topout CA PD 07/16/2008 31 Underground/Condmt-Wirinq PA PY CONDUIT ONLY 05; 97? MTGi www mtglmc com Corporate 2992 E La Raima Ave Anaheim CA 92806 Tel 7146322999 Fax 714 632 2974 Dispatch 800 491 2990 Ste A MTGL Project #__ Perm,t*_tf A S>%fff ~1C]_ Report #_ PG. San Diego/Imperial County" 7313 Carroll Rd Ste G San Diego CA92121 Tel 8585373999 Fax 8585373990 Dispatch 888 844 5060 DAILY INSPECTION REPORT Inland Empire 14467 Meridian Pkvvy Bldg 2-A Riverside CA92518 Tel 951 653 4999 Fax 951 653 4666 Dispatch 800 491 2990 DSA/CITY File # .. DSA/OSHPDAPPL# DSA/LEA# Special Inspection Reports must be distributed to the parties listed below within 14 days of the inspection Reports of non compliant conditions must be distributed immediately Separate reports shall be prepared for each type of special inspection on a daily basis Each report shall be completed and signed by the special inspector conducting the inspection PROJECT NAML DATE ARCHITECT IME ARRIVED TIME DFPARTFD ENGINEER TRAVFI TIMt LUNCH TIMF CONTRACTO,SUB CONTRACTOR INSPECTION ADDRESS ADDRESS Ol PROJECT TYPE OF INSPECTION f ENGINEERED FILL i FOUNDATION •' BACK FILL " I BATCH PLANT H PT CONCRETE I SHOTCRETE _! CONCRETE MASONRY _ HIGH STRENGTH BOLTING WELDING _ SHOP WELD FIFJIEPROOFING Ir^'NCHOR/DOWEL NDE FIELD . NDESHOP J CEILING WIRE DSA/OSHPD/PROJECT APPROVED DOCUMENTS AVAILABLE APPROVED PLANS Y SOIL REPORT Y~l NH SPECS YL Nil APPROVED SHOP DRAWING Y j NT MATERIALS USED BY CONTRACIOR (INCLUDE RESEARCH RFPORT NO OH MATERIAL TEST REPORTS) " tee •£.. CONTRACTORS EOIIPMENT / MANPOWFR USED AREA GRIUUNLS PIECES INSPECTED STRUCTURAL NOTES DETAIL OR RFIS USFD L, V -? <S RLMAHKS INCLUDING MEETINGS 77.r7 y T REWORK AS PERCENT OF ALL WORK TODAY PERCENT PROJECT COMPLETE THE WORK WAS V WAS NOT" Inspected in accordance with the requirements of the DSA/OSHPD/PROJECT approved documents MATERIAL SAMPLING WAS I WAS NOT N/A Peiformed in accordance with DSA/OSHPD/PROJECT approved documents cc Proiect Architect Contractor Structural Engineer Building Department DSA Regional Office Owner School District THE WORK INSPEC FED MET i*DID NOT MEET J THE requirements of the DSA/OSHPD/PROJECT approved documents Samples taken (K~ Weather (^*"_ *-'<*"/ Temp __ *7 "^T* ^* ^^.^ - '-» fr^^-^^gy~, 7" *"*" « Signafure~of Special Inspector Print Name Certification Verified by J EsGil Corporation In (Partnership with government for Quiftfmg Safety DATE July 14, 20O8 O-ARpyc, JURISDICTION City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO 08-0979 , SET III PROJECT ADDRESS .M&SCalle Barcelona Suite 154 PROJECT NAME Paper Source - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes 2<] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has beeo completed _ Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person XI REMARKS OK to issue with applicant replacing sheets A10 & AVI in set II with the new sheets A10 & A11 marked set III Also Set II was incomplete Please pj/ce the sheet E201 marked Set I in set II Received one set only By Bryan Zuppiger Enclosures Set(&) I & II Esgil Corporation D GA D MB D EJ D PC 07/08/2008 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 + Fax (85S) 560-1576 EsGil Corporation In Partnership with government for <Buiftftng Safety DATE 6/25/08 JURIS JURISDICTION City of Carlsbad ^Q-Ptfl a FILE PLAN CHECK NO O8-0979 SET II -*93«PROJECT ADDRESS -*93« Calle Barcelona Suite 154 PROJECT NAME Paper Source - TI I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Permit Resources Inc / Mary Ryan P O Box 3749 Mission Viejo, CA 92690 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mary Ryan Telephone # 949-582-3735 Date contacted ^V^(byV*43) Fax # 949-768-8436 Maw Telephone Faxy^ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 6/19/08 9320 Chesapeake Drive Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 City of Carlsbad O8-O979 6/25/08 RECHECK CORRECTION LIST JURISDICTION City of Carlsbad PLAN CHECK NO O8-O979 PROJECT ADDRESS 1935 Calle Barcelona Suite 154 SET II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED ESGIL CORPORATION 6/19/08 6/25/O8 REVIEWED BY Doug Moody FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Building Code, Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations The approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit new complete sets of prints to B To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo City of Carlsbad O8-O979 6/25/08 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue 1 Please clarify the section view of all new interior partitions Show a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" b) Method of providing lateral bracing for wall type B Please indicate in the detail the method of attaching the brace to the floor slab and provide calculations for the attachment c) Please correct the wall legend for wall type C Ihe 2 Vz studs are not rated for the span to the roof as shown in the elevations as 27' 11 Show that the water closet is located in a space, per Section 1115B 3 2 3, which provides a) A minimum side clearance of either i) >28" from a fixture n) >32" from a wall on one side b) A clear space in front of the water closet measuring 60" wide by 48" in front Section 1115B 4 1 2 Please provide a copy of the manufacturer's specification for the tank type water closets in the rest rooms to show the 24" water closet to be elongated bowl and disabled accessible 12 Doors in the room shall not swing into the clear floor space required for any fixture Maintain the required clearances at the lavatory/water closet without the entry door swinging into those areas Section 1115B 3 2 2 See comment 11 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc City of Carlsbad O8-0979 6/25/08 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGil Corporation In Partnership witH government for <BuiC<fmg Safety DATE 6/4/08 OAPPLJCANT JURISDICTION City of Carlsbad Q FILE PLAN CHECK NO 08-0979 SET I PROJECT ADDRESS 1935 Calle Barcelona Suite 154 PROJECT NAME Paper Source - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Permit Resources Inc / Mary Ryan P O Box 3749 Mission Viejo, CA 92690 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Ma/y Ryan Telephone # 949-582-3735 Date contacted 4^/°^(by//£3) Fax # 949-768-8436 MaiV/ Telephone Fax^/ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 5/28/08 9320 Chesapeake Drive, Suite 208 * San Diego California 92123 * (858)560-1468 *• Fax (S5S) 560-1576 City of Carlsbad O8-O979 6/4/O8 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO O8-0979 OCCUPANCY M TYPE OF CONSTRUCTION VB ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 5/27/08 DATE INITIAL PLAN REVIEW COMPLETED 6/4/O8 JURISDICTION City of Carlsbad USE Retail ACTUAL ARE A 3810 STORIES I HEIGHT OCCUPANT LOAD 115 DATE PLANS RECEIVED BY ESGIL CORPORATION 5/28/08 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e, plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans City of Carlsbad 08-O979 6/4/08 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Dnve, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Ftte Departments until review by EsGil Corporation is complete 1 Please clarify the section view of all new interior partitions Show a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" b) Method of providing lateral bracing for wall type B c) Please correct the wall legend for wall type C the 2 Vz" studs are not rated for the span to the roof as shown in the elevations as 27' 2 Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 3 Please complete the LTG-1 -C part 2 of 4 mandatory automatic controls portion of the LTG-1-C forms 4 Please have the principle designer check the appropriate box(s) and complete the Statement of Compliance System Acceptance section of the LTG-1-C part 4 of 4 documents 5 Please revise the LTG-2-C form to show the track load from the LTG-9-C form 6 Please revise the plumbing plans to show the required clean-outs per section 707 and 719 of the UPC 7 Show P & T valve on water heater and detail drain line route from P & T valve to the exterior UPC Section 608 4 8 Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36" long and no more than 28" to 34" high ' City of Carlsbad 08-0979 6/4/O8 (the counter must be permanent a flip up counter is no longer permitted) Section 1122B5 9 Where fixed or built-in tables, counters or seats are provided for the public, and in general employee areas, 5% (but never less than one) must be accessible Please revise the plans to show the break room counters accessible Section 1122B 1 10 Plans shall indicate that drinking fountains comply with Section 1115B 4 6 as either a) Located completely in an alcove, >32" in width and >18" in depth b) Positioned to not encroach into accessible pedestrian ways 11 Show that the water closet is located in a space, per Section 1115B 3 2 3, which provides a) A minimum side clearance of either i) >28" from a fixture n) >32" from a wall on one side b) A clear space in front of the water closet measuring 60" wide by 48" in front Section 1115B 41 2 12 Doors in the room shall not swing into the clear floor space required for any fixture Maintain the required clearances at the lavatory/water closet without the entry door swinging into those areas Section 1115B 3 2 2 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporalion located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad O8-0979 6/4/O8 City of Carlsbad O8-O979 6/4/08 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O8-O979 PREPARED BY Doug Moody DATE 6/4/08 BUILDING ADDRESS 1935 Calle Barcelona Suite 154 BUILDING OCCUPANCY M TYPE OF CONSTRUCTION VB BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code Rlrlo Permit FPP hv Orrlina AREA (Sq Ft) 3810 cb Valuation Multiplier 3437 By Ordinance nee ! •v I Reg Mod VALUE ($) 130,950 130,950 $700 41 Plan Check Fee by Ordinance Type of Review [2 l~~i Repetitive Fee ~^~> Repeats Complete Review D Other (—1 Hourly Structural Only Hour* Esgil Plan Review Fee $455 27 $392 23 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB /7?D?79 DATE AHHPCCQ RESIDENTIAL RES IDENTIAL ADDITION MINOR (<$10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER ENGINEER DATE DATE Coc*Ui*»Tr»Rifinino En PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHEECKLIST i Calle Barcelona £ S(0 na Q 533 a a s0.0.0. EDO an an Plan Check No CB080979 Address; Planner Deborah Milam Phone (760) 602- 4619 APN 255-012-04 Type of Project & Use JJ Net Project Density DP/AC Zoning P-C General Plan R/O/RMH Facilities Management Zone _ CFD (in/out) #_Date of participation Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit Legend Item Complete Item Incomplete - Needs your action YES D NO D TYPEEnvironmental Review Required DATE OF COMPLETION _ Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval _ Discretionary Action Required YES D NO Q TYPE _ APPROVAL/RESO NO _ DATE _ PROJECT NO __ OTHER RELATED CASES _ Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES Q NO Q CA Coastal Commission Authority? YES Q NO Q If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan Data Entry Completed? YES D NO D If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') Inclusionary Housing Fee required YES D NO Q (Effective date of Inclusionary Housing Ordinance - May 21,1993) Data Entry Completed? YES Q NO D (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08 £• Site Plan EDO Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines IEI D D 1 Applicability YES D NO D D D D 2 Project complies YES Q NCQ n Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope Required. Required. Required. Required Required. D 2 Accessory structure setbacks Front Required. Interior Side Required. Street Side Required. Rear Required. Structure separation Required. 3 Lot Coverage Required. Shown. Shown. Shown. Shown. Shown Shown. Shown. Shown. Shown. Shown. Shown D D 4 Height Required Shown Spaces Required.Shown5 Parking not shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments Correction #1 Please show how new and moved roof-mounted equipment will be screened from around level view See attached handout Correction #2 Please show parking required and parking provided in a parking tabulation on the first page Parking required is 1 space per 200 square feet of gross floor area OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08 Carlsbad Fire Department Plan Review Requu emenls Categoiy TI, COMM Date ot Report 06-23-2008 MARY RYAN Re viewed by Name Address PO BOX 3 749 MISSION VIEJO CA 92690 BLDG. DEPT COPY Permit* CB080979 Job Name PAPER SOURCE-3810 SF RETAIL TO Job Address -r9S5 CALLE BARCELONA CBAD St 154 „,)„,-,, .„*„!.. ,J,,,>* „ .„ *„ ,!„*„....,..„„ n».««l.n«nn ,,,.tl- Conditions Cond CON0002817 [NOT MET] 1 Indicate- Fire Extmguishci locations Fire Extinguishers shall be located in conspicuous locations, readily accessible, and along normal paths of travel ChC 906 and 906 5 2 Note "(If requned) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry slandpipes, halon systems and other special types of automatic fire protection systems and appurtances thereto shall be submitted to Carlsbad Fue Department for review and approval PRIOR to installation (CTC 901 2)" 3 Note "Only mam exterior door or doois aie permitted to be equipped with a key-operated locking device from the egress side in accordance with CFC 1008 1 6 All others shall be no knowledge, single action in accordance with CFC 1008 1 8 and 1008 184" Indicate main entrance and note hardware for second exit Hntry 06/03/2008 By cwong Action CO Cond CON0002873 [METJ **APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF 1SSUEANCT OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT 1 O FIELD INSPECTIONS ANY REQUIRED 1ES fS, FIRE DEPARTMENT NOTATIONS, CONDi^HONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHAI L NOT BL HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 06/23/2008 By cwong Action AP Carlsbad Fire Department Plan Review Recfiiv ements Categot y TI, COMM Date of Report 06-03-2008 Reviewed by Name MARY RYAN Address P O BOX 3 749 MISSION VIEJO CA 92690 Pei nut # CB080979 BLDG. DEFT COPY Job Name PAPER SOURCE-3810 SF RETAIL TO JobAddiess -W35 CALLE BARCEl ONA CBAD St 154 INCOMPLETE 1 he item you have submitted Ibi review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/oi standards Please review carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval Conditions Cond CON0002817 [NOT MET] 1 Indicate Fire Extinguisher locations Fire Extinguishers shall be located in conspicuous locations readily accessible, and along normal paths of travel CTC 906 and 906 5 2 Note "(If required) Complete plans and specifications tor fire alarm systems, fiie extinguishing systems, including automatic spunklers and wet and dry standpipes, halon systems and other special types ot automatic tire protection systems and appurtances theielo shall be submitted to Carlsbad Fire Department for review and appioval PRIOR to installation (CFC 901 2)" 3 Note "Only mam exterior door or doois aie permitted to be equipped vvith a key-operated locking device from the egress side in accordance with CFC 1008 1 6 All others shall be no knowledge, single action in accordance with CFC 1008 1 8 and 1008 184" Indicate main enttance and note hardware for second exit Entry 06/03/2008 By cwong Action CO CADET™ RIGHT HEIGHT™ 14" ROUGH-IN ELONGATED TOILET VITREOUS CHINA CADET™ RIGHT HEIGHT™ 14" ROUGH-IN ELONGATED TOILET J 2998 014 • Vitreous china • Low-consumption (6 0 Lpf/1 6 gpf) • 16-1/2" rim height for accessible applications • 14" roughing-m • Elongated siphon action jetted bowl • AquaForce flushing technology • Fully glazed 2" trapway • Close-coupled tank with raised lip detail on tank cover • Color-matched trip lever • Speed Connect™ tank/bowl coupling system • Sanitary bar on bowl • 2 bolt caps • 100% factory flush tested J 3417 016 Bowl J 4114 016 Tank Alternate Tank Configurations Available G 4114 600 Tank complete with tank cover locking device J 4114 800 Tank complete with trip lever located on right hand side Nominal Dimensions 806x495x813mm (31-3/4" x 19 1/2" X 32") Fixture only, seat and supply by others Compliance Certifications - Meets or Exceeds the Following Specifications • ASME A11219 2M for Vitreous China Fixtures - includes Flush Performance, Ball Pass Diameter Trap Seal Depth and all Dimensions /- fiN SHED WALL !»' •ISiniT' i 6mm • TM * I A) 27Brnn 'ID _ BOfiTrn _ 11 3/11 470/mn ~"M6 1'?)" ^ C/L OF SEAT POST HOLE! / '•»"""•'«-""=™' To Be Specified J Color J Seat American Standard #5324 019 Rise and Shine" solid plastic closed front seat with cover J Seat American Standard #5311 012'Laurel" molded closed front seat with cover j Alternate Seat J Supply with stop NOTES THIS TOILET IS DESIGNED TO HOUGH IN AT A MINIMUM OIME.N jlON OF 356mm (14 ) FROM FINISHED WALL TO C/L OF OUTLET SUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDFRFD SEPARATELY • DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTFD IMPORTANT Dimensions ot fixtures are nominal and may vary within the it,n |t of tolerances established by ANSI Standard A112 19 2 These measurements are subject to change or cancellation No rpsporibihi'u/ -, assumed for use of superseded or voided pages MEETS THE AMI RICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117 1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES-CHECK LOCAL CODES ©2006 American Standard Inc K55 Revised 5/05 AtMn&w Sbwdtrd CADET™ RIGHT HEIGHT™ ELONGATED TOILET VITREOUS CHINA CADET™ RIGHT HEIGHT™ ELONGATED TOILET :j 2998012 • Vitreous china • Low-consumption (6 0 Lpf/1 6 gpf) • 16-1/2" rim height for accessible applications • Elongated siphon action jetted bowl • AquaForce flushing technology • Fully glazed 2" trapway • Close-coupled tank with raised lip detail on tank cover • Color-matched trip lever • Speed Connect™ tank/bowl coupling system • Sanitary bar on bowl • 2 bolt caps • 100% factory flush tested Q 3417 016 Bowl Q 4112 016 Tank J 2998164 with Slotted Rim for Bedpan holding LJ 3417164 Bowl CJ 4112 016 Tank Alternate Tank Configurations Available J 4112 300 Tank complete with chrome all metal trip lever _J 4112 500 Tank complete with Aquagard liner J 4112 600 Tank complete with tank cover locking device J 4112 700 Tank complete with Aquagard liner and tank cover locking device CJ 4112 800 Tank complete with trip lever located on right side J 4112 900 Tank complete with tank cover device and trip lever located on right side Nominal Dimensions 756 x 495 x 813mm (29-3/4' x 19-1/2" x 32") Fixture only, seat and supply by others Compliance Certifications - Meets or Exceeds the Following Specifications • ASME A112 19 2M for Vitreous China Fixtures - includes Flush Performance Ball Pass Diameter Trap Seal Depth and all Dimensions To Be Specified J Color j Seat American Standard #5324 019 Rise and Shine" solid plastic closed front seat with cover j Seat American Standard #5311 012'Laurel" molded closed front seat with cover j Alternate Seat _i Supply with stop NOTESTHIS TOILET IS DESIGNED TO ROUGH IN AT A MINIMUM DIMENSION OH 305MM (12 ) FROM FINISHED WALL TO C/L OF OUTLETSUPPLY NOT INCLUDE D WITH FIXTURE AND MUST BE ORDEREDSEPARATELY* DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED IMPORTANT Dimensions of fixtures are nominal and may vary within the ra igi of tolerances established by ANSI Standard A112 19 2 These measurements aie subject to change or cancellation No responsibility is assumed for use ol superseded or voided pages MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117 1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES-CHECK LOCAL CODES €> 2006 American Standard Inc K53 Revised 5/05 CADET™ RIGHT HEIGHT™ 10" ROUGH-IN ELONGATED TOILET VITREOUS CHINA CADET™ RIGHT HEIGHT™ 10" ROUGH-IN ELONGATED TOILET J 2998 010 • Vitreous china • Low-consumption (6 0 Lpf/1 6 gpf) • 16-1/2" rim height for accessible applications • 10" roughing in • Elongated siphon action jetted bowl • AquaForce flushing technology • Fully glazed 2" trapway • Close-coupled tank with raised lip detail on tank cover • Color-matched trip lever • Speed Connect™ tank/bowl coupling system • Sanitary bar on bowl • 2 bolt caps • 100% factory flush tested J 3417 016 Bowl J 4110 016 Tank Alternate Tank Configurations Available J 4110 600 Tank complete with tank cover locking device J 4110 800 Tank complete with trip lever located on right hand side Nominal Dimensions 705 x 495 x 813mm (27-3/4" x 19-1/2" x 32") Fixture only, seat and supply by others Compliance Certifications - Meets or Exceeds the Following Specifications • ASME A112 19 2M for Vitreous China Fixtures - includes Flush Performance, Ball Pass Diameter, Trap Seal Depth and all Dimensions To Be Specified -i Color J Seat American Standard #5324 019 Rise and Shine" solid plastic closed front seat with cover j Seat American Standard #5311 012'Laurel" molded closed front seat with cover J Alternate Seat J Supply with stop NOTESTHIS TOILET IS DESIGNED TO ROUGH IN AT A MINIMUM DIMENSION OF 254mm (10 ) FROM FINISHED WALL TO C/L OF OUTLETSUPPLY NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED SEPARATELY« DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED IMPORTANT Dimensions of futures are nominal and may vary within the of tolerances established by ANSI Standard A112 19 2 These measurements are subjec t to change or cancellation No responsibility is assumed for use of superseded or voided pages MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117 1 REQUIREMENTS FOR ACCESSIBLE AND USABLE BUILDING FACILITIES-CHECK LOCAL COOES <g2006 American Standard Inc K54 Revised 5/05 •Rr (&«-.-"r>?--> -v,. "-'-SHl f;*-i /P=*-y\,> ,j"f ?•' ,. ,, - jipf^wjfftfi.^ i f K>W&'ff3J&g*isl ",''•?**?'''^1"/rj- ' ^W^'^e^'.H"-,-^^^ ^'i^""^ , •'«%^4.^ -:-:;5, -r CERTHOLDER COPY COMPENSATION INSURANCE PO BOX 420807, SAN FRANCISCO CA 94142-0807 F-UND CERTIFICATE OF WORKERS' COMPENSATION INSURANCE ISSUE DATE 02-15-2008 GROUP OOO238 POLICY NUMBER 0008967-2007 CERTIFICATE ID 1 CERTIFICATE EXPIRES O2-01-2009 02-08-2008/02-01-2009 SD SUMMIT DEVELOPMENT. INC PO BOX 1131 CARDIFF BY THE SEA CA 92007-7131 SO JOB OR OE SANTOS 3257 LOS COCHES ROAD CARLSBAD CA 92007 This is to certify that we have issued a valid Workers Compensation insurance policy in a form approved by the California Insurance Commissioner to the employer named below for the policy period indicated This policy is not subject to cancellation by the Fund except upon 10 days advance written notice to the employer We will also give you 10 days advance notice should this policy be cancelled prior to its normal expiration This certificate of insurance is not an insurance policy and does not amend extend or alter the coverage afforded by the policy listed herein Notwithstanding any requirement term or condition o'f any contract or other document with respect to which cms certificate of insurance may be issued or to which it may pertain the insurance afforded by the policy described herein is subject to all the terms exclusions and conditions of such policy JTHORIZED REPRESENTATIVE PRESIDENT EMPLOYER'S LIABILITY LIMIT INCLUDING DEFENSE COSTS $1 OOO 000 PER OCCURRENCE ENDORSEMENT #16OO - HARDING MATTHEW R P S T - EXCLUDED EMPLOYER CASCADE ELECTRICAL CONTRACTING CORP DBA SAFEWAY ELECTRIC 2245 ENTERPRISE ST ESCONDIDO CA 92029 SD (REV 1 051 [B16SD] PRINTED 02-15-2008 Check A License Contractor's License Detail Page 1 of2 Skip to CSLB Home | Content | Footer | Accessibility I Searct- Department of Consumer Affairs GOV Contractors State License Board i L:i ft -r^iff] rtfmn nrnfTi iffmrfrrmffi^ 1 01 1 02 1 03 1 ' CONSUMERS 1 CONTRACTORS APPLICANTS P1^ V" * * /"* •Kv^'V ** ^-?^P^5 ^Qp^Ptpl^^l1^ About CSLB CM B Newsroom g-J'^^&itCv^^t^J JO (2<^I£.tf^»^ i&Zz'.dCf •&'''r*£s%f&fj3//£tf ; 3iiMiiffMnrii iiTnmmiill i 04 1 05 1 fl JOURMEYMEN PUBLIC WORKS B .^ ,^,,or^ ^a^^^j|H^^K e ' o? ! ' UILD1HE OFFICIALS GENERAL INFO c c w n@^e VB.< E m& E&un H^CONTJ^TOR'sYlCENSEpETAiL; '-. '.V^^^.i-'l'^'"' | •'..•/' ''^•'^^•..rl^ !"' ' ^\ A B<...<>rd eind Committee Mt I'll I..'!! 0 « .slet Information C onl ••• CSL6 U'hniy F ro(|u»ntiy Asked Gin ^liiins Online Services o ^ ^eci- ,fl Licsnse or HIS f 1'ing a Crnstfuciion Co ipl«ji,n y ii i >\ i ) ^ ' x lii i I ni-i rjiio ( if ai v i i fpvisa'! r Cc How to Participate ili D/SCLA/MER A //cense steti/s cnecA provides information taken from the CS/.B license database Before relying on this information, you should be awat the following limitations • CSLB complaint disclosure is restricted by law (B&P 7124 6) If this entity is subject to pu complaint disclosure a link for complaint disclosure will appear below Click on the link oi obtain complaint and/or legal action information • Per B&P 7071 17 only construction related cii/il judgments reported to the CSLB are disc • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitr, • Due to workload there may be relevant information that has not yet been entered onto th license database License Number Business Information Entity Issue Date Expire Date License Status Classifications Bonding 568818 Extract Date 07/15/21 SUMMIT DEVELOPMENT & BROKERAGE INC p O BOX 1131 CARDIFF CA 92007 Business Phone Number (760) 634 1888 Corporation 05/23/1989 05/31/2009 This license is current and active All information below should b reviewed GEN.ERAL BUILDING CONTRACTOR This license filed Contractor's Bond number 100021213 in the of $12,500 with the* bonding company AMERICAN CONTRACTORS INDEMNITY COMPANY Effective Date 04/04/2007 Contractors Bonding History 1 The Responsible Managing Officer (RMO) STEVEN MERRIL MURRAY certified that he/she owns 10 percent or more of ttn voting stock/equity of the corporation A bond of qualifying individual is not required Effective Date 05/23/1989 http /Avww2 cslb ca gov/General-lntormalion/mteractive-tools/check-a-license/License+ 07/15/2008 Check A License Contractor's License Detail Page 2 of2 Workers This license has workers compensation insurance with the Compensation STATE COMPENSATION INSURANCE FUND Policy Number 18 14467 Effective Date 01/01/2005 Expire Date 01/01/2009 Workers Compensation History Personnel listed on this license (current or disassociated) are listed on other licenses Consumers | Contractors | Applicants | Journeymen | Public Works | Building Officials | General Info CSLBHome | Conditions of Use | Privacy | Contact CSLB Copyright © 2007 State of California http //ww\v2 cslb ca gov/General-Information/inteiactive-tools/check-a-hcense/License+ 07/15/2008