HomeMy WebLinkAbout1911 Calle Barcelona; 151; CBC2018-0349; Permit(City of
Carlsbad
Commercial Permit
Print Date: 10/30/2018 Permit No: CBC2018-0349
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
It Dwelling Units:
Bedrooms:
1911 Calle Barcelona, 151
BLDG-Commercial
2550120400
$91,066.58
Work Class: Tenant Improvement
Lot#:
Reference #:
Construction Type:
Bathrooms:
Orig. Plan Check It:
Status:
Applied:
tssued:
Permit
Finaled:
Inspector:
Closed -Finaled
06/26/2018
08/27/2018
MColl
Plan Check#:
Final
Inspection: 10/30/2018 10:15:00AM
Project Title:
Desc ri pti on: SEOERA: 1,958 SF RETAIL TO RETAIL Tl
Applicant: Owner: Contractor:
STEPHANIE BISHOP
143 S Cedros Ave, L
T-C FORUM AT CARLSBAD LLC ELYSIAN CONTRACTORS INC-INACTIVE
Solana Beach, CA 92075-1914
760-419-6860
4675 Macarthur Ct Tiaa-Cref, 110
NEWPORT BEACH, CA 92660
143 S Cedros Ave, Ste AlOS
Solana Beach, CA 92075-1914
760-632-8533
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
5B1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $1,141.00 Total Payments To Date: $1,141.00 Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" offees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$592.06
$414.44
$60.00
$45.00
$4.00
$25.50
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: •PLANNING •ENGINEERING
('cicyof
Carlsbad
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUllE#/SPACEf/UNIT#
16 \
•BUILDING
PHASE# # BEDROOMS # BATHROOMS TENANT BUSINESS NAME
•FIRE
SC.D Rt\
•HEALTH OHAZMATIAPCD
-O{)
occ. GROUP
D~;°;;,;0;;,~udeiq~Fptg;cto~~~e~T tflov/l Wlµb 0\0RG To 5ttOG
s-roR6..,, ,-.)Gv-J GQe53 l/'-)~ R.a::>cvt ~ f '5,o0.AG,£ vJ A-l,L-
e,-t. L-L°"t-rr-Reitorv~i~v~100 I Cl5't ~F
PA nos (SF) DECKS (SF)
CIT'/ BUS. LIC.#
FIRE SPRINKLERS
YES•No•
(Sec. 7031.5 Business and Professions Co<le: Any City or County which requires a permit to construct. alter, improve, demolish or repair ant structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code I or that he Is exemi;,t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than fwe hundred dollars ($500)).
Workers' Compensation Declarallon: I hereby affirm under penally of petjury 0/le of the following declaralions, Q I have and will maintain a certificate of consent to self-Insure for workers" compensatlon as provided by Seclion 3700 o! the Labor Code, for the performance of the work for which this permit is issued.
ps.11 have and will maintain wo~compansation. as reQuired by Section 3700 of the Labor Code. for the performance of the work for which this permit is issued. My workers' compensalion insura;rcarri_x and policy
numberaro:lnsuranceco. R{¼oM:Y:) l~2RP,clt-G Ct) PollcyNo.6t,..W(!.A7B9q:z E~piralionDale .5-,J ,,
J.llii,_ section need not be compleled if lhe permit is for one hundred dollars ($100) o, less. LJ Certificate of Exemption: I certify that in the pelformance of the work for which this permil is issued, I shall not employ any person in any manner so as lo become subject to the Workers' Compensation laws of
Calttomia. WARNING: Failure to se<;ure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and clvtl fines up to one hundred thousand dollars (&100,000), in
addition to !he cost of compensaUon, d m e provided IBP-lq_ Section 370 of the La or code, Interest and attorney's fees.
RS CONTRACTOR SIGNATURE .
I hereby affirm that I am exempt from C011fraclor'5 Ucense Law for the following reason: •
• •
I, as owner of the property or my employees with wages as their sole compensafion, wlll do the work and the structure is not intended or offered for sale (Sac. 7044, Business and Professions Code: The Contractor's
Licarise Law doos not apply to an owner of property who builds or improves thereon, end who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, lhe building or improvement is sold within one year of completion, the owner•builder will have the burden al proving thal he did not build or improve for the purpose of sale).
t, as owner of the property, am exclusively contracting with licensed co,tractors to construct lhe project (Sec. 7044, Business and Professions Code: The Contractor"s License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projecls with contractor(s) licansed pursuant to the Contractor"s License Law).
I am exempt under Section ___ ~Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement 0Yes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have conlracted with the following person (firm) to provide the proposed construction (lncluue name address r phone I contractors' license number):
4. 1 plan lo provide portions of Iha work, but I have hired the following person to coordinate, supervise and provide lhe major work (include name I address I phone I contractors· license numberf:
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the worll indicale<l {include name I address I phone I type of work):
RS PROPERTY OWNER SIGNATURE •AGENT DATE ,~----•~J
. . .
C (U/1 ft I,,; E T ! sf tU ii uu; Jr u:q1~ I ~ I. NJ.'> Jj , R 11,t,! ~ fH'if ~Jt ' l.l°:U D UUri 'IU" I MLIJI\S O ~ I 111 . ' :< : ' 'p 00
\0 ' '
Is the applicant or future blJilding occupant required to submit a business Pl,, acutely hazardous materials registration form or risk managernen1 and prevention program under Sectio!ls 25505, 25533 or 25534 of the
Presle}" Tanner Hazardous Substance Account Act? • Yes r, No tL
Is the applicant or future building occupant required to obtain a pem,it from the air pollution control diwict or air.~ality management district? • Yes 1" No
Is the facility to be C(lllstructed within 1,000 feet of the outer boundary of a school stte? • Yes ~ No
IF Atf't OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND ntE AIR POLLUTION CONTROL DISTRICT.
I C8l1lly that I have read the appllcatlon and slats that the above lnfonnation Is correct and that the lnfoonation on the pl811S Is accurate. I agree to comply with all Cify ordinances and State laws relating to building construction.
I hereby alAhorize representative of 1he Ctty of Carlsbad to enter upon the above mentioned property fur inspection purposes. I ALSO AGREE TO SAVE, INOEMNFY ANO KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN Af«WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: M OSHA penri is requiTed for excavations over 5'0' deep and demolition or construction of sbuctures over 3 stories in height
EXPIRATION: Every permit issued by 1he Building Official under the provisions of this Code shal expire by irntaliOn and become nul and void if the bulding or v.ork au1horized by such permit is not (l)nlrr,enced within
180 days from the date of such pennil or if. bu or work authorized pem, · is susµended or abandoned at any lime after Iha work is oomrnenced for a period ol 180 days (Section 10&4. 4 Uniform Buiding Code~
A!$ APPLICANT'S SIGNATURE
PERMIT INSPECTION HISTORY REPORT (CBC2018-0349)
Permit Type: BL DG-Commerci a I Application Date: 06/26/201 B Owner:
Work Class: Tenant Improvement Issue Date: 08/27/201 B Subdivision:
Status: Closed -Finaled Expiration Date: 04/17/2019 Address:
IVR Nurnber: 12151
Actual Scheduled
Date Start Date Inspection Type Inspection No.
08/28/2018 08/2812018
08/30/2018 08/3012018
1011612018 10/1612018
1011912018 10/1912018
10/3012018 10/30/2018
BLDG-14
Frame/Steel/Bolting/
Welding (Decks)
068337-2018
Checklist Item
BLDG-Building Deficiency
BLDG-34 Rough
Electrical
068338-2018
Checklist Item
BLDG-Building Deficiency
BLDG-17 Interior
Lath/Drywall
068747-201 B
BLDG-Final
Inspection
BLDG-Final
Inspection
BLDG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
073193-2018
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Electrical Final
073674-2018
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Electrical Final
074461-201 B
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Plumbing Final
BLDG-Electrical Final
BLDG-Electrical Final
NOTES Created By
Inspection Status Primary Inspector
Passed Michael Collins
COMMENTS
Back of house & fitting rm walls
Passed Michael Collins
COMMENTS
Walls only at back of house & fitting room
Passed Michael Collins
COMMENTS
Failed Michael Colllns
COMMENTS
See ca rd for pick up
Cancelled Paul Burnette
COMMENTS
See card for pick up
Passed Michael Collins
COMMENTS
Mirror not installed in restroom.
See card for pick up
TEXT
T-C FORUM AT CARLSBAD LLC
CARLSBAD TCT#92-08 GREEN
VALLEY
1911 Calle Barcelona , 151
Carlsbad, CA 92009-8454
Re Inspection
Passed
Yes
Passed
Yes
Passed
Yes
Relnspection
Passed
No
No
No
Reinspe<ction
Passed
No
No
No
Passed
Yes
No
No
Yes
No
Yes
Complete
Complete
Complete
Complete
Complete
Complete
Complete
Created Date
Michael Collins mirror not installed at restroom. Fitting room
compliance ok.
10/30/2018
October 30, 2018 Page 1 of 1
✓• EsG1I
A SAFEbuilt Company
D APPLICANT
,,,ZJURIS.
DATE: 08/22/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-0349 SET: III
PROJECT ADDRESS: 1911 Calle Barcelona
PROJECT NAME: Sedera T.I.
[8'.I The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
[8'.I EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted:
Mail Telephone
0 REMARKS:
Telephone#:
(by~ Email:
Fax In Person
By: Dwight Ashman (For M.B.)
EsGil
08/15/2018
Enclosures:
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
DATE: 8/9/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-0349
✓• EsG1I
SET: II
PROJECT ADDRESS: 1911 Calle Barcelona
PROJECT NAME: Sedera T.I.
• APPLICANT • JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Es Gil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Stephanie Bishop
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
•
Person contacted: Stephanie Bishop Telephone#: 760-809-4587
Date contacted: 1{:)/\0 (by:~) Email: StephanieBishop@msn.com; ,-
katherine el s c .com ,,-
Mail ~e Fax In Person
REMAR~
By: Morteza Beheshti
EsGil
8/2
Enclosures:
9320 Chesapeake Drive. Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
City of Carlsbad CBC2018-0349
8/9/2018
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK#.: CBC2018-0349
OCCUPANCY: M
TYPE OF CONSTRUCTION: VN
ALLOWABLE FLOOR AREA:
SPRINKLERS?: Y
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 1/9
DATE INITIAL PLAN REVIEW
COMPLETED: 8/9/2018
FOREWORD {PLEASE READ):
JURISDICTION: City of Carlsbad
USE: Retail
ACTUAL AREA: 1958 sf
STORIES: 1
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/2
PLAN REVIEWER: Morteza Beheshti
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBC2018-0349
8/9/2018
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
• PLANS
1. Provide a Building Code Data Legend on the Title Sheet. Include the following
code information for each building proposed: DUE TO OCCUPANCY LOAD
THE EMERGENCY LIGHTING AND EGRESS DOORS MUST BE SPECIFIED.
2. Sales and service counters shall have a portion of the counter which is at
least 36" in length with a maximum height of 34 inches. Section 11 B-904.4.1
DRESSING ROOMS
3. Mirrors shall be installed with the bottom edge of the reflecting surface 20
inches (508 mm) maximum above the finish floor or ground. Mirrors shall
be full length with a reflective surface 18 inches (457 mm) wide minimum
by 54 inches (1372 mm) high minimum and shall be mounted in a position
affording a view to a person on the bench as well as to a person in a
standing position. 11 B-803.6
ELECTRICAL, and ENERGY COMMENTS
4. Please provide a completed electrical lighting, controls and power design for
review. ONE OF THE ELECTRICAL PANELS DOES NOT HAVE THE CODE
REQUIRED CLEARNCE DUE TO PART OF THE 2' BENCH IN FRONT.
5. Please demonstrate how emergency egress exit lighting will be provided.
6. Please provide completed energy compliance forms for review. PLEASE
INCLUDE TRACK LIGHTING ENERGY FORMS.
DISABLED ACCESS REVIEW LIST
City of Carlsbad CBC2018-0349
8/9/2018
DEPARTMENT OF STATE ARCHITECT
TITLE 24
ACCESSIBLE PARKING
1. The words "NO PARKING" shall be painted on the ground within each
loading and unloading access aisle (in white letters no less than 12" high
and located so that it is visible to traffic enforcement officials). Section 118-
502.3.3.
2. Show that a bumper or curb is to be provided, and located at each space, to
prevent encroachment of cars into the required width of walkways, per
Section 118-502.7.2.
3. Show or note that the maximum slope of the parking surface at the
accessible space and adjacent access aisle, in any direction, is :S 1 :48, per
Section 11 B-502.4.
4. Show or note on the plans that the accessible parking spaces are to be
identified by a reflectorized sign, permanently posted immediately adjacent
to and visible from each space, consisting of:
a) A profile view of a wheelchair with occupant in white on dark blue
background.
b) The sign shall :t:70 in.2 in area.
c) When in the path of travel, they shall be posted :t:B0" from the bottom
of the sign to parking space finished grade.
d) Signs may also be centered on the wall of the interior end of the
parking space.
e) Van-accessible spaces shall have an additional sign "Van-Accessible"
mounted below the symbol of accessibility.
f) In addition, the surface of each accessible space is required to be
marked with the international symbol of accessibility.
END OF DOCUMENT
To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes. please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction
list? Please indicate: • Yes • No
City of Carlsbad CBC2018-0349
8/9/2018
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Morteza Beheshti at Esgil. Thank you.
✓• EsG1I
DATE: 7/11/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-0349
PROJECT ADDRESS: 1911 Calle Barcelona
PROJECT NAME: Sedera T.I.
SET: I
D APPLICANT
D JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Es Gil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Stephanie Bishop
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Stephanie Bishop
Date contacted: o/\'v (by~) Email:
~~\lephone Fax In Person
0 ~RKSi ~ ~
By: Morteza Beheshti
EsGil
6/28
Telephone#: 760-809-4587
Stephanie Bishop~~~(,,(h\be,t'""
Enclosures:
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
City of Carlsbad CBC2018-0349
7/11/2018
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK#.: CBC2018-0349
OCCUPANCY: M
TYPE OF CONSTRUCTION: VN
ALLOWABLE FLOOR AREA:
SPRINKLERS?: Y
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 1/9
DATE INITIAL PLAN REVIEW
COMPLETED:7/11/2018
FOREWORD (PLEASE READ):
JURISDICTION: City of Carlsbad
USE: Retail
ACTUALAREA: 1958sf
STORIES: 1
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 6/28
PLAN REVIEWER: Morteza Beheshti
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list {or a copy) where each
correction item has been addressed. i.e., plan sheet number. specification section. etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBC2018-0349
7/11/2018
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
• PLANS
1. Provide a Building Code Data Legend on the Title Sheet. Include the following
code information for each building proposed:
• Occupancy Classification(s)
• For Mixed Occupancy Buildings, state whether the "nonseparated" or
"separated" option was chosen from Sections 508.3/508.4.
• Type of Construction
• Sprinklers: Yes or No
• Stories
• Height
• Occupant Load
• Justification to exceed allowable area in Table 506.2 (if applicable)
• Justification to exceed allowable height or stories in Tables 504.3/504.4 (if
applicable)
2. All Plans and calc's to be signed by the responsible professional.
3. Indicate 2016 California Electrical Code on cover sheet.
4. Sales and service counters shall have a portion of the counter which is at least 36"
in length with a maximum height of 34 inches. Section 11 B-904.4.1
DRESSING ROOMS
5. A circular or t-shaped turning space complying with Section 11 B-304 shall be
provided within the dressing rooms. 11 B-803.2.
City of Carlsbad CBC2018-0349
7/11/2018
6. Doors shall not swing into the dressing/fitting room unless a turning space
complying with Section 11 B-304.3 is provided beyond the arc of the door swing.
11 B-803.3
7. A bench complying with the provisions of section 11 B-903 shall be provided
within the dressing/fitting room. 11 B-803.4
8. The bench shall be 48" long and 20" minimum to 24" maximum deep.
9. The bench shall be 17" minimum to 19" maximum above the finish floor.
10. The bench shall be affixed to the wall or floor and shall withstand a vertical or
horizontal force of 250 pounds.
11. A clear floor or ground space in compliance with 11 B-305 shall be provided at
the end of the bench parallel to the short axis of the bench.
12. Coat hooks provided within the room shall be located within one of the reach
ranges specified in Section 11 B-308. Shelves shall be 40 inches (1016 mm)
minimum and 48 inches (1219 mm) maximum above the finish floor or ground.
Coat hooks shall not be located above the bench or other seating in the room.
11 B-803.5
13. Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches
(508 mm) maximum above the finish floor or ground. Mirrors shall be full length
with a reflective surface 18 inches (457 mm) wide minimum by 54 inches (1372
mm) high minimum and shall be mounted in a position affording a view to a
person on the bench as well as to a person in a standing position. 11 B-803.6
• SITE PLAN
14. Provide a fully dimensioned site plan drawn to scale. Sec. 107.2. Include the
following:
a) Clearly dimension building setbacks from property lines, street centerlines,
and from all adjacent buildings and structures on the site plan.
b) North arrow.
c) Property lines/easements.
d) Streets/alleys.
e) Existing and proposed buildings and structures.
15. Show dimensioned parking layout, including any required disabled access
spaces. Section 107.2.
• ACCESSIBILITY
City of Carlsbad CBC2018-0349
7/11/2018
16. Each lot or parking structure where parking is provided for the public, as clients,
guests or employees, shall provide accessible parking as required by Section 11 B-
208.2.
17. Show a sufficient space in the toilet room for a wheelchair to enter the room
(including approach from hallway ) and close the door, per Section 11 B-603.2. The
space is required to be:
a) ;::60" diameter.
b) AT-shaped space as shown in Figure 11 B-304.3.2.
c) Doors are not permitted to encroach into this space by more than 12
inches.
18. Show that the water closet is located in a space which provides (see picture guide
below):
a) A clear space at the water closet in compliance with Section 11 B-604.3.2
(this prohibits any fixtures from encroaching into the clear space at the rear
wall).
b) A clear space in front of the water closet measuring 60" wide by 48" in front.
Section 11 B-604.3.1. See the following figures.
i) Please notice that the 28" clearance required in the previous code
(between the water closet and the lavatory) has been changed to a
60" clearance as shown in the figure.
City of Carlsbad CBC2018-0349
7/11/2018
Nf~ ~~
FLUSH
ACTIVATOR
ON WIDE
SIDE---
60"MlN.
CENTERLINE
OF
FIXTURE
CENTERLINE
OF
FIXTURE
iT-18"
I
~ ~ ~ I N 2
\
\
18~
MIN.
I .2s•M1N, rHJ
TOEDGE L_j
OF 'NATER -' CLOSET
\ .. ~-9:-z 0::: \ ~ < ~~ ¼~ UJ '<:I~ (J'v ) ~ -1 00 0 <}'t-' ~ /
/
/ --_,,.
I 18" \ 32" MIN
-MIN.~
ELECTRICAL, and ENERGY COMMENTS
19. Please provide a completed electrical lighting, controls and power design for
review.
20. Please demonstrate how emergency egress exit lighting will be provided.
21. Please provide completed energy compliance forms for review.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
ACCESSIBLE PARKING
City of Carlsbad CBC2018-0349
7/11/2018
1. Show on the site plan the required number of accessible parking spaces for new
facilities.
2. Show that the accessible parking spaces are located, per Section 11 B-208.3.1 as
follows:
a) On the shortest possible route to an accessible entrance, when serving a
particular building.
3. The words "NO PARKING" shall be painted on the ground within each loading and
unloading access aisle (in white letters no less than 12" high and located so that it
is visible to traffic enforcement officials). Section 11 B-502.3.3.
4. Show that a bumper or curb is to be provided, and located at each space, to
prevent encroachment of cars into the required width of walkways, per Section
11B-502.7.2.
5. Show or note that the maximum slope of the parking surface at the accessible
space and adjacent access aisle, in any direction, is s 1 :48, per Section 11 B-
502.4.
6. Show or note on the plans that the accessible parking spaces are to be identified
by a reflectorized sign, permanently posted immediately adjacent to and visible
from each space, consisting of:
a) A profile view of a wheelchair with occupant in white on dark blue
background.
b) The sign shall '270 in.2 in area.
c) When in the path of travel, they shall be posted 280" from the bottom of the
sign to parking space finished grade.
d) Signs may also be centered on the wall of the interior end of the parking
space.
e) Van-accessible spaces shall have an additional sign "Van-Accessible"
mounted below the symbol of accessibility.
f) In addition, the surface of each accessible space is required to be marked
with the international symbol of accessibility.
END OF DOCUMENT
To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes. please briefly
describe them and where they are located in the plans.
City of Carlsbad CBC2018-0349
7/11/2018
Have changes been made to the plans not resulting from this correction
list? Please indicate: • Yes • No
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Morteza Beheshti at Esgil. Thank you.
Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and
Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the
review process, note on this list (or a copy) where the corrected items have been
addressed on the plans.
City of Carlsbad CBC2018-0349
7/11/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: Morteza Beheshti
BUILDING ADDRESS: 1911 Calle Barcelona
BUILDING OCCUPANCY: S 1 /B
BUILDING AREA Valuation
PORTION (Sq.Ft.) Multiplier
Tenant Improvement
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
1997 UBC Building Permit Fee
1997 UBC Plan Check Fee
Type of Review:
D Repetitive Fee
.., Repeats
Comments:
By Ordinance
...
....
Complete Review
0 Other
u Hourly
EsGII Fee
PLAN CHECK#.: CBC2018-0349
DATE: 7/11/2018
Reg. VALUE ($)
Mod.
per city
91,067
$587.161
$381.651
D Structural Only
$334.681
Sheet of
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS
QUESTIONNAIRE
OFFICE USE ONLY
RECORD ID# _________________ _
PLAN CHECK# ________________ _
BP DATE
The following questions represent th cility's ctivities, NOT the specific project description.
PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not required for projects within the City of San
Diego}: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled,
applicant must contact the Fire Protection Agency wilh jurisdiction prior to plan submittal.
Occupancy Rating: Facility's Square Footage (including proposed project):
1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives
2. Compressed Gases 6. Oxidizers 10. Cryogenics
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
A Other Health Hazards CY None ofThese.
PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS DIVISION (HMO}: If the answer to any of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Avenue, Suite 110, San Diego, CA 92123.
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy: • Ca!ARP Exempt
I
1. Is your business listed on the reverse side of this form? (check all that apply).
Y~ES INO (for new construction or remodeling projects) Date Initials
2. Will your business dispose of Hazardous Substances or Medical Waste in any amount?
3. Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 • CalARP Required
I
4.
5.
6.
7.
8.
• • • • •
pounds and/or 200 cubic feet? ro Will your business store or handle carcinogenslreproductive toxins in any quantity?
'rgj, Will your business use an existing or install an underground storage tank?
~ Will your business store or handle Regulated Substances (CalARP)?
,81, Will your business use or install a Haz.ardous Waste Tank System (Title 22, Article 10)?
~ Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to
or realer than 1,320 allons? California's Above round Petroleum Stora e Act .
Date Initials
• CalARP Complete
I
Date Initials
PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCOl: Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San
Diego, CA 92131 apcdcomp@sdcounty.ca.goy (858) 586-2650). [*No stamp required if 01 Yes and 03 Yes and 04-06 No]. The following questions are intended
to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not identified by these questions. For comprehensive
requirements contact APCD. Residences are typically exempt, except -those with more than one building• on the property; single buildings with more than four
dwelling units; townhomes: condos; mixed-commercial use: deliberate burns; residences forming part of a larger project. rExcludes garages & small outbuildings.]
1.
2.
3.
4.
5.
6.
YES NO • .5 Will the project disturb 160 square feet or more of existing building materials?
B ~ Will any load supporting structural members be removed? Notification may be required 10 working days prior to commencing demolition.
(ANSWER ONLY IF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance
Technician? •
•
•
D (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 10 working days prior to commencing asbestos removal. Ji{J Will the projecl or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet
(www.sdapcd.org/info/facts/permits,pdf) for typical equipment requiring an APCD permit. D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda
Briefly describe business activities:
{p I ,;;J,5 I /fl
Signature of Owner or Authoriz.ed Agent Dale
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: _____________________________ _
BY: DATE: I I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMO* APCD COUNTY-HMO APCD COUNTY-HMO APCD
. . *A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other perm1tt1ng requirements may still apply .
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
(City of
Carlsbad
WASTE MANAGEMENT
PLAN
B-59
RECety~t ~er~i_c~s
ldmg D1vmon
JUN 2 6 ZOJB635 Faraday Avenue
760-602-2719
CITY OF CARLS~1ttfarlsbadca.gov
DIVISION
Owner: Contractor: -6k'/5tAN ~£l~ci<6 y,.;L
Job Address:} 9 f I CALL6 {3Pe.C-6LONA Phone Number: 7/oQ-310 ~q .J3{o
Permit#: Estimated Cost of Project: $....,,'9_,,,().,,_1,_.0IX)........,."-'-""'----------
Type of Project: D New Construction )[Remodel or T.I. • Residential ~ Commercial • Demolition
(check all that apply) D Other ------------------------------
Non-hazardous construction waste generated during the course of this project shall be recycled and/or salvaged for re-use at a
minimum of 65% per CALGreen Sec. 5.408.1. Failure to comply may result in a penalty fee up to $1,000. For projects which
consist of mainly equipment and/or racking, that have a combined weight of new construction disposal that does not exceed 2
lbs per square foot of building area affected by this permit, may be deemed to meet the 65% minimum requirement upon
approval of Building Department.
ALTERNATIVE FORMS OF COMPLIANCE: (If selected, do not complete Tables 1 & 2 below)
D Construction waste shall not exceed 2 lbs. per sf. of area. All receipts shall be provided to the Building Official prior to
final. (This option not applicable for most construction projects.)
Square feet of construction area. _______ X 2 lbs.= ________ lbs. of allowable waste.
~ I plan on using a WASTE MANAGEMENT roll-off bin. All receipts shall be provided to the Building Official prior to final.
Table 1 -Estimated Waste (To be filled out prior to permit issuance -refer to example on Page 2.)
MATERIALS lbs. of waste to be taken to lbs. of waste to be Waste Hauling Company or Re-Use Method LANDFILL RE-USED or RECYCLED
Asphalt / Concrete
Brick/ Masonry
Cardboard I fl!)/)
Drywall ""---...... ,.j'DM \N0.6Tl5 M Dr..._,Af>_,,,nMr;:,#Sl -r:r .JI JI.,/
Landscape Debris r I
Lumber/ Wood 470
Metals ~ nn11
Mixed Waste '
Trash/ Garbaf!e I AfJV
Other: !
TOTAL lbs:
Estimated Percentage to be Re-Used or Recycled_~7i'-'5 ___ %
Official Use Only
D Plan Approved D Plan Denied D Project Valuation Approved
Reviewed/ Approved by: ________________ ~
Page 1 of 2 REV.01-2017