HomeMy WebLinkAbout1913 ALGA RD; F; CB940005; PermitBUILDING PERMIT
01/12/94 15:12
Job Address: 1913 ALGA RD
Page 1 of 1
Permit Type: MISCELLANEOUS
Parcel No: 215-170-03-16
Valuation: 32,000
Construction Type: NEW
Occupancy Group:
Description: REPAIR FOUNDATION
I F' Suite :
Lot#:
Reference#:
=
Project No: A9400006
Permit No: CB940005
Development No:
~ .. .. ,I .~. . . .,
.. f-
.. .
Applied: 01/04/94
Status: ISSUED
Apr/Issue: 01/12/94 Entered By: DC
Awwl/Ownr : SOIL ENGINEERING CONSTRUCTION 619 741-9170 "
456 N. QUINCE STREET
ESCONDIDO, CA 920
*x* Fees Required d & Credits
""""""""""""
Fees :
- - - - - - - - - - -
Adjustments: .oo
Total Fees: 194.00
298.00
Fee description Ext fee
"""""""""" - - - - - - - - - - -
Miscellaneous Fee # 194.00
Miscellaneous Fee # * MISCELLANEOUS TOT
298.00
492.00
*x*
Data
PLANCHECK
BLDGPERMIT
INbP. DATE
LEARANCE //
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
P abL7 LlCATlON
City of Carlsbad Building DepartlPnt 2075 Las Palms Dr., Carlsbad, U pzwp (619) 438-1161
A . 0 Commercial U New Bulldlng U'lenant Improvement
UL/- 5- PLAN CHECK NO. /
B - 0 Industrial 0 New Building OTenant Improvement
C - OResidential OApartment OCondo OSingle Family Dwelling OAdditiom/Alteration ;f"l&
0 Duplex 0 Demolition 0 Relocation 0 Mobile Home 0 Electrical 0 Plumbing
0 Mechanical OPool 0 Spa ORetaining Wail OSolar OOther &G(y I
2 PRmmKMAnoN FOR OFFICE USE ONLY ?9"1.; A~+bm tlulldlng or Sum No.
Nearest Crm Street 5ul-w F bL6" a
ON Lot No. Subdlnsron NamdNumber Unit No. Phase No.
__ . "" . . . . -. -. . .. . . " .
02 Energy Cala 0 2 Structural Calcs 02 Soils Report 0 1 Addressed Envelope
USE
NAMF
INSURANCE COMPANY c E -(
Certltlcate of Exemptlon: 1 certlty that In the pertorman& ot rhe work 1or Whlch thls perm11 IS Issued. I Shall not employ any person I" any manner
so as to home subjex to the Warken' Compensation Laws of California.
mum NO& C/QU~+, EXPIRATION DATE / a - / 9
SIGNATURE DATE
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
Owner-Bullder Declaration: 1 hereby atflrm that 1 am exempt from the Contractor's license Law tor the tollawtng reason:
offered far sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improver thereon, and who dm such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, rhe owner-builder will have the burden
of proving that he did nor build or improve for the purpose of sale.).
0 I, as owner of the property, am exclusively contracting with licensed contracton to construct the project (Sec. 7044, Busings and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projecu with conuactor(s) licensed pursuant to the Contractor's License Law).
0 I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to tile a signed statement that he is licensed pursuant to the provisions of the Contractor's License law (Chapter 9, commencing with Section 7000 of Division 3 of the Busings and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subject, the applicant to a civil penalty of not more than five hundred dollan [$.500]).
SIGNAlllRe Mn? COa
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
Is the applicant or future building occupant required to obtain a permir from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
IPANYOFmAN~AREYE$APINAL~~~n?OFOCCUPAN~~YNOTBElSSUED-JULY1,1989UNIPSS~APPUCANT
0 YES
OYES
0 YES
0 NO
0 NO
0 NO
HAS m OR IS MFE~~~G nce wuummas OF nce oma OF EMERGENCY mwa AND m AIR FO-N OD~OL DISIIUCT.
I hereby altmn that there IS a constructm lendmg agency lor the performance of the work lor Whlch thls permlt IS tssued (sec 3097(1) unl we).
LENDER'S NAME LENDER'S ADDRESS
1 certlty that 1 have read the appllcatron and state that the above lnformatlon IS correcr. 1 agree to comply wlth all Clty ordlnances ana State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
AND EXF'ENSFS WlUOl MAY IN ANY WAY ACCRUE AGAINST SAID (TIY IN mNSEQUENCE OF niE GRANTING OF llm WIMFI:
MU: An OSHA permit is required for excavations over SO" deep and demolition or construction of structures over 3 stories in height
purposes. IAlsoffiREEmsAvE~EMNIEYANDKEEp~~~(TIyoFuRIsBIu)ffi~~Au.IuB~JuDG~cosIs
"
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 02/25/94 PERMIT# CB940005
DESCRIPTION: REPAIR FOUNDATION INSPECTOR AREA TP
PLANCK# CB940005
OCC GRP
CONSTR. TYPE NEW TYPE: MISC
JOB ADDRESS:
APPLICANT: SOIL ENGINEERING CONSTRUCTION PHONE: 619 741-9170
1913 ALGA RD STE : LOT :
OWNER: CONTRACTOR:
REMARKS : MH/ROSS/ INSPECT0
SPECIAL INSTRUCT:
TOTAL TIME:
CD LVL DESCRIPTION ACT COMMENTS
11 ST Ftg/Foundation/Piers
"
"
" -
***** INSPECTION HISTORY *****
DATE DESCRIPTION
012794 Ftg/Foundation/Piers
022294 Steel/Bond Beam
ACT INSP COMMENTS
PA PD
AP TP POST PILE FTNS INT.
SLAB-PENDING ENG. APPROVAL
c .
CML ENGINEERING CONSULTANTS
619 So. Vulean A~auq Suite 210
C. J. Rand19 P.E, Resident
Endnltar, Callfmnia 92024
phone: (619) 5444124
February 21, 1994 Fm (615') 942-6043
City of Carlsbad Building Inspection Department
Carlsbad, California 92009
2075 Las Palmas Drive
Attention: Building Inspection Department
Slab and Reinforcement Observations Ross Residence
1913-F Alga Road Carlsbad. California
Gentlemen:
This letter has been prepared to confirm that Civil Engineering Consultants has observed the preparation of the slab subgrade and
reinforcing steel placement for the slab-on-grade at 1913-F Alga Road, in Carlsbad. The purpose of these observations was to assess the conformance of the slab subgrade and reinforcement preparation
with the intent of the construction drawing prepared by Soil Engineering Construction.
An engineer from this office visited the site on February 22, 1994 to observe slab subgrade and reinforcement preparation. Contractor retied steel reinforcement to comply with the construction drawing
prepared by the undersigned. Our observations indicated that the slab and reinforcing steel placement comply with the construction drawing and was approved for concrete placement.
-0oo-
additional information, please feel free to call us. If you have any questions regarding our report, or require
Very truly yours,
CIVIL ENGINEERING CONSULTANTS
L-hWQa JJ%&"
Charles J. Randle, R.C.E. 22096
JwN:cJR:oo1
CNIL. STRVCTUPAL, AND SOILS ENGINEERNO GEOLOGY .SUtiVEY CERTlFlED INSPECnON .SOIL AND MATERIM TESTING FEPSl0lLilV STUDIES CONTR4Cl MANAGEMENT
N.C.E.E. #4170 CA R.C.E. #G22098 AZ RC.E. #I1971 0 NV R.C.E. #3037 0 WA C.E. 110776
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO. CA 92123-1021
(619) 660-1468
January 11, 1994
Mr. Pat Kelley Building Official City of Carlsbad
Carlsbad, CA 92008
2075 Las Palmas Drive
RE: Plan Check #94-05 Address: 1913 Alga Rd., Unit F Carlsbad
Dear Mr. Kelley:
Transmitted herewith are plans for proposed foundation repairs, to attempt to mitigate continued settlement of the existing foundation and to further prevent resulting structural damage.
Esgil Corporation cannot offer any guarantees that the proposed system will resolve the.present problems, nor should the City offer
may result in enhanced foundation support system from the current such representation. However, acceptance of the proposed remedies
situation.
At the time of permit issuance the following should be noted on the plans: "Prior to the City building inspector approving final inspection, the responsible design professional shall notify the building official, in writing, that the proposed foundation repairs have been installed in accordance with the design".
Sincerely, ESGIL CORPORATION
Ali Sadre, S.E. Plan Check Engineer
AS/cc
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208
SAN DIEGO. CA 92 I23
(619) 560-1468
'PY
?LAN CHECK NO: os 4rt - 03 SET: r EUPS
PROJECT ADDRESS : lq I3 &\.%a ed . *F DDESIGXR
v
0 necessary and substantially comply with the jurisdiction's The plans transmitted herewith have been corrected where
building codes.
fl with the iurisdicfion's buildins codes when minor deficien- The plans transmitted herewith will substantially. comply -
' cies idenfified - are resolved and
checked by building department staff.
0 identified on the enclosed check list and should be corrected
The plans transmitted herewith have significant deficiencies
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
plans zre submitted for recheck.
The applicant's copy of the check list is enclosed for the
The plans are being held at Esgil Corp. until corrected
0 jurisdiction to return to the epplicant contact person. m The applicant's copy of the check list has been sent to:
Chuck 'i2&6d\r CEL . bi4 3 .du/~- QUCC,
81 Esgil staff did not advise the applicant contact person that plan check has been completed.
0 Esgil staff did advise applicant that the plan check has been completed. person contacted:
Date contacted: Telephone B
-
0 REMARKS:
By : rL\, sAhe Enclosures: Jeonb,
ESGIL CORPOMTION
OGA 0 CM 0 PC
I t
JANUARY 5. 1994
TO: DORlSlMlKE
FROM: PAT K.
RE: CB 94-5 FOUNDATION REPAIR
I WANT ESGIL'S ENGINEERS TO APPROVETHIS PLAN PRIOR TO AUTHORIZING ANY
CONSTRUCTION ON THIS PROJECT.
PLEASE HAVETHE APPLICANTCOMPLETE THE APPLICATION PRIORTO ISSUANCE,
SUCH AS DESCRIPTION OF WORK AND WORKERS COMPENSATION CATEGORY.
ALSO, THE APPLICATION LISTS ONE ADDRESS AND THE PLANS SAY TWO
BUILDINGS (THEY ARE MULTI-UNIT BUILDINGS). PERHAPS A SITE PLAN
ACCURATELY SHOWING WHICH UNITS ARE SUBJECT TO THIS REPAIR PERMIT
WOULD FOCUS THIS DISCREPANCY.
/
September 20, 1993 Revised September 21, 1993
Casitas de la Costa Homeowners Associatbn
c/o William Wyman, Attorney at Law
6994 El Camino Real, #201
Carlsbad, CA 92029
RE: Summary of Findings at 1913 and 1937 Alga Rd.,
La Costa. CA -
Ref. No. '93-283
Dear Mr. Wyman:
The following report presents additional iriformation which has been developed since
our interim report dated August 24, 1993. Also as a part of this transmission is
an estimate to construct three areas which are deemed necessary for first phase
repair.
Since our meeting of August 24, 1993 this office has advanced four observation
wells located across the northerly perimeter of the building 1913 .and they were
located in such a manner as to incorporate units D, E, F, and G. An additional
two borings (i.e. observation wells) were located at the southerly end of building
1937 unit G. As of this date moisture is beginning to collect within these wells
with exception of the well located in front of the Ross residence (1913-F). In this
observation well water was located an approximate 5.5 feet below grade. Due to
the nature of the impervious soil material the observation wells will be reflective of
the actual groundwater conditions within the coming two to three weeks.
Structural observations were conducted within units E, F, and G at building 1913
on September 17, 1993 by the undersigned and Osman Pekin, PE, PhD. the
primary reason for our site visitation was to evaluate the conditions of the adjacent
units to the Ross condominium and more particularly to determine the conditions of
the timber roof system consisting of roof joists and a ridge beam, which is common
to both units F and G. However, unit E is constructed on a separate system of
bearing walls and has little or no common support systems with units F and G.
+
456 N. Outnce Street Escondldo. CA 92025 * (619) 741-7645 * FAX 1619) 741-9170
September 20, 1993
Casitas de la Costa
Page two
Conclusions based upon visual observations by Dr. Pekin, P.E. indicate that the
structural capabilities of the roof system is adequate at the present .time. There is
no cause for immediate repairs or associated danger to the residents or the
structure. However, it is important to recognize that the continued observation of the two units F and G should be considered relative to the forthcoming several
months. This particularly relates to the wood support structures and additional
items which will be mentioned later in the text of this report.
A system of two survey monuments were established at the front and rear of the
condominium unit F. The second check on September 15, 1993 reflected no
movement. Based on this relatively stable condition it has been determined that the
continued monuments evaluation will be done on a monthly basis, pending any change in movement detected at either the north or southerly foundation.
The extent of repairs summarized here for your information will be further
expanded upon within the text of this report. The first and probably foremost requirement will be the installation of a "French drain" cut off wall constructed
across the northerly wall system for units F and G. A detail for this construction
work is also attached for your edification (see plate D). The approximate length of
this French drain system will be on the order of fifty lineal feet constructed to a
depth of at least 6 feet (contingent on the location of the footings for units F and
G.) The easterly terminus of the French drain will require connection to a closed
system which will then run underground to the southerly parking lot and be
outletted in such a manner as to not create any erosion and align with existing
drainage. The estimated cost for this type of drain system is attached in Appendix
G.
Installation of four 4" diameter hydraugers, entering beneath the footing are further
recommended to be located as noted in exhibit C, where as these borings will be
installed horizontally beneath the deepened footing along the southerly wall. This
system will then be incorporated to a closed drain system to be outletted through
the slopes and ultimately to toe of the slope and into existing drainage facilities.
The interior slab in the lower portion of the Ross condominium should be removed
in its entirety. Measured from the southerly rear patio door approximately 14 feet
into the condominium. The removal of this slab and of course ultimate
replacement is necessitated due to the extensive cracking and ground water intrusion
through the slab concrete mass either by capillary action or in some areas where
the cracks are wide enough to provide a conduit for moisture intrusion. However,
portions of the slab reflected a rather heavy concentration of mildew parallel to and
adjacent to the slab on grade patio door way. The results of core boring tests
reflected the water conditions throughout the sub-slab area in the Ross unit.
September 20, 1993
Casitas de la Costa Page three
To further assure that the gross foundation stability of the condominium units can
be relied upon a system of mini-piles are recommended to be placed around the
periphery of the load bearing footing within the lower half of the split level unit F.
These piles should be driven to refusal and will be designed to withstand well in
excess of the design loads of the wood frame condominium structure. These piles
will logically be spaced at or about 5 feet center to center and then be connected
in a manner as to assure vertical support for the existing bearing foundation
structure. Please be advised mini-piles are for vertical support only and at this
particular plan of repair, lateral support appears to be unnecessary. In the event
this situation develops lateral supports may simply be the inclusion of a tieback
located at the condominium unit to depths necessary to obtain the ability to
withstand any lateral movement. These tiebacks can either become a part of the
pipe-pile system or some manner of grade beam system which may have to be
constructed at a later date. However, based on our evaluation of the surrounding
site and the report which has been previously provided to the homeowners
association by American Geotechnical, it becomes evident that the degree of the
stress relates almost entirely to the excessive water which has been noted throughout
our investigation.
To further determine the source of the underground water problems it is highly
recommended that existing ponds and waterways throughout the development be
tested with a dye to trace the course of any waters which may have leaked through
the waterway system either through cracks, overflow or other means of water loss.
Regarding the continuing sow of water movement throughout the condominium
project, alternate aesthetic landscape methods should be thoroughly evaluated by the homeowners association. The undersigned and several of my associates who have
consulted with me on this project conclude that the constant exposure to water and
moisture does nothing but precipitate the problem and in fact works almost in a
catalytic manner. In order to maintain the apparently well received aesthetic value which incorporates the running water, appropriate means should be employed to
ensure that this system i.e. waterfalls and streams are not involved in any leaks.
In summary the work necessary in a phase I approach to the repair of unit F and
parts of unit G relates to the removal of the conditions causing the settlement,
unacceptable moisture conditions and essential differential movement throughout the
structure; this specifically relates to groundwater control.
September 20, 1993
Casitas de la Costa
Page four
Requirements for repair of the slab in the Ross condominium is necessitated by the
significant amount of water encountered during our investigation. Normally
adequate drainage would solve this type of excessive moisture content. However,
the impervious nature of the soils and the medium to highly expansive nature of
these soils which comprise the foundation system for building 1913 will be slow to
give up water thus a system of drains or other means would not provide a prompt solution to the over wet conditions. Therefore it is prudent to remove the slab and
a minimum of 24 inches of sub slab soil to be replaced with coarse gravel (not
sand) and compacted to an equivalant 95% of relative compaction. The gravel shall
be covered with a visqueen 6 mil. minimum membrane overlain with at least 2
inches of sand. The concrete slab shall be at least 5 inches in thickness, all edges
shall be constructed to prevent bond with the existing footings. Minimum slab
reinforcement shall be #4 bars at 12" O.C. each way placed at the mid point.
Finally some effort will be made to release any additional water which has collected
beneath the zone measuring 24 inches below the bottom of the proposed new slab.
These corings and drainage instruments will aid in the final correction to the
groundwater conditions which are so prevalent at unit F. This procedure requires
four lateral drains be located below the existing southerly deepened footing and be
outletted through the southern slope in a controlled manner to the existing drains
located in the parking lot.
The basis of this report initially was to direct our attention. to the conditions
surrounding the condominium owned by Ms. Ross mainly unit F .within building
1913. However, in light of the surrounding conditions which has been previously
reported by American Geotechnical and our visual observations of the slopes (the
trees leaning significantly downslope) indicate that there is an underlying problem
within the immediate area which require prompt attention. This consideration may
best be handled by the installation of slope monitoring devices to assure that the slope stability is adequate and will not affect the structures. Further observations
of the water wells is recommended to ensure that the groundwater conditions do
not reach unacceptable limits. The monitoring which is recommended for the
timber structural members in units F and G could very easily be accommodated by
the inclusion of "tattletale" monitoring tapes which will be installed at various
critical areas. Constant observation and measurement of these devices will indicate
the continued movement and/or distress. Additionally measurements should be taken
to ensure that the structural members are not undergoing any sign~f~cant differential
settlement. At first observation it would appear that the large structural members
have undergone some 'form of torquing from front to back (i.e. from north to
south). The movement apparently is significant enough to create the crack
observed. However, it is difficult to establish the exact direction of the movement
September 20, 1993
Casitas de la Costa
Page five
when structural members undergo both rotational and settlement deformations. We
have included a compilation of construction costs which have been developed by
our firm for your board of directors review and hopeful approval of this work.
It is the undersigned's opinion that the extent of work be limited to the proposed
water/French drain system along the northern wall, slab replacement and the
monitoring devices. The work necessary to auger and create additional drainage
facilities will be an important part of the repair; however, this might be set aside or
become a part of Phase I1 operations contingent on the results of continued
monitoring, evaluations of the slope stability and determination of the extent of
water caused throughout the system.
We look forward to your review of this report and the attached preliminary report. Our sketches and recommended corrective procedures are all attached as Plates A
through G.
Thank you for this opportunity to provide our service to your organization.
Sincerely, , A
Charles J. Randle, PE
RCE 220% CA
CJWsr
cc: William Wyman
Leslie Leonhardt @man Pekin
Roger Zimmerman
ill
I Sottom @ 6.5‘
Ltefusal or concrete debris
- FIELD LOG
I m I
I 1 I
I c
I
CC Dark Brown, soft, saturated sc/cc
nottom @ a 1/2'
I
Gray Brown Fine Sand, traces of clay moist
Numerous chunks of asphalt and concrete debris
Wet
Bottom of Boring 12 3'
= Urive Samples
1 PROEE=T HALE Alga 1913 IFCURE HC.
Plate A-4
L- I
Dace: 8-16-93 Field Reo.: CT
Drill Rig: Hand Awered
BORW NO. 2 SOIL DESCRIPTION
Fill
Bottom of boring 4 +/- feet
Refusal or chunks of asphalt and concrete debris
FIELD LOG
T
i
i
I
I
i
'i'
i
PLATE B BORING LOCATIONS
I
I
- " __ " -, . __ .. . .. ." .- - " -. . - - - . .- -- - - - - .. .- "" '' ..
- This procedure requires four lateral drains be located below the existing
southerly deepened tooting and be outletted through the southern slope in
a controlled manner to the existing drains located in the parking lot. ,m PLATE C
MINI-PILE/HYDRAUGER LOCATION:
m
cn m m
JJ m 77 0
;D "I
0 JJ >
Z > 0 m
H
m
"I 0
n
0 cn m 0
r
r
Z rn
H
Z 0 n "I I
-n 0 Z
c Z
-4
H
.. cn
-+
0 m rz-
"I
LJ- m
I+
r
-rl
JJ m Z
c"1 Z
-0 zn < om r-"
.U r-
f-
5 "I m
m
GENERALNOTES
1. The pipe pile design contained on this
Engineering Construction. Inc. The sheet is the property of Soil
details presented illustrate the patented Mini-PileTM system. This
Engineering Construction. Inc. and its design is for the sole use of Soil
clients.
2. Drive Mini-PileTM with properly operating 90 lb. pneumatic or hydraulic hammer.
3. Unless otherwise noted. all concrete shall attain a minimum strength of 2000 psi at 28 days.
4. Rebar shall be gr. 40 or better.
PLATE E - 2
LABORATORY RESULTS
Location
Cores H-1 @ 11"
58"
36"
72"
H-2 @ 21"
H-3 @ 16"
36"
65"
84"
98"
Borings B-1 @ 56"
72"
B-2 @ 36"
DENSITY TESTS
Location
Boring B-1 @ 56"
M.C. UBC
(Exp. Index)
24.5 59
26.0
22.1
23.3
22.0
20.0
22.6
20.7
22.0
25.6
13.0
20.0
15.0
87
03
MAXIMUM DENSITY /OPTIMUM MOISTURE
Density Max. Den. Opt. Moist.
#/C€ X/C€ %
108.2 121.3 13.0
PLATE F
- SOIL
-v-
Casitas de In Costa Homeowners' Assn.
c/o William Wyman, Attorney at Law
6994 El Camino Real #201
Carlsbad. CA 92009
Suhject: Investigative Report, suhsurface conditions and associated settlement
Reference: SEC, Inc.
and distress noted at 1913 Alga Rd., Unit F, La Costa, CA
Bid No. 93-283
Dear Mr. Wyman:
The following report is considered to be interim, pending our complete report which will
include nll soil data information and boring logs relative to our investigation of the subject
site.
Essentiillly, the results of our investigation reflect the continued moisture intrusion due to
a lack of i\de(]uafe drainwge, both surface and suhsurface, in and around the building wllich
is known as 1013 Alga Road. Our investigation was directed only at Unit 1913-E
Prior to our investigation we reviewed the reports by American Geotechnical, which are as
follows: Mmh 7, 1987 and December 7, 19x7, file No. 20221; file No. 20623 which is dated
November 7, 198X, M~ch 13, 1989 and August 23, 1989. Information presented by
American Geotechnical is, for all intents and purposes, identical to the findings which we
encountered during our investigation. It is possibly significant to recognize that the
measured differential settlement repoeeti hy American Geotechnical across the rear portion
of the condominium lower floor has increased nominally, by possihly .25 inches, based on
our recent measurements.
Our investigation involved the mapping of the numerous cracks noted within the slab-on-
grade and is reflected in the attachment to this report. In addition to this original survey of
the cracked areas, a m:lnometer was run throughout the first and second floors of this rlnit.
The mnximum settlement appears to he on the order of two inches at the sliding glass door
exit to the concrete patio, measured relative to the gradient observed at the laundry
entrance area (see sketch).
The problcm is a lack of adcquatc subsudacc drainage aud surface drainage controls. This
condition continues to influence the foundation system lor Unit F. Moisture intrusion
ccmtinues throughout the basement area and is reflecled in sxtrcnxly high saturated
moisture contents in. three Iccatiom where concrete co:cc I?!!::: cut t!iwugh ;!IC lowcr shb.
Upo~ c~~~~plction of the coring of the concretc 3 Iland auger was uscc! tn samplc to depths
varykg from three to nine feet. AI1 moisture contents were in cxxss sf 20%. with some as
liigh as 26%. T!we values a:e at, or near, saturatian. To compound this cmdition, thc soils
wiliill !IG.;~ besl ni~~surtxi rcflcc: :I ltigll crpansivc hc~vc po!cllti2!.
Casitas de la Costa Homeowners' Assn.
August 24, 1993
Page 3
This system can then be constructed in a manner t pilc cap and, ultimately,
a new grade beam to be placed along the existing y foundation stemwall. This new
structural system may then be jacked back to the approprkte elevations. It should be noted
that duiizs t11c jacking process extrenwcarz should-be t&en..to assure thal.the structural -
member, Le. exposed timber roof system, nct ufidcrgo azy further distress-and, with the
reestablisl~ment of initial garie, the IongiPadinal Sties cracks should be reduced. In the
event this stress is not relived within the timber struhra! system, further analysis should be
unuertakcrl to assure that the niemhers he. adequate sirxturrrl capcity. Repairs in rhis
area arc not .witithin !:ic.purview of this report; howcvcr, tkis- not a significant!y cxpcnsive
rcpair sb~uld il be repired.
The slab-on-grade nlay :hen be reconstructed on a ytem of =hi-piles drivcn to refusal at
approximately eight foot on center grid pattern. The slab should te five inches in thickness
and reinforced according to the structural engineer's standards. This new slab will then be
constructed in such a maniier as to preclude any further distress from settlement and the
expansive soil andition will be negated due to the removal to a depth of 24 inches and
replaccmeut with gravel.
Finally, the exterior slope and lower retaining wall which was previously recommended for
repair should not be overlooked. The lateral resistance to thc structure's stability is
dependent on a dense and adequately constructed engineered slop. This will require
removal of the expansive materials and replacement with materials w!l!ch are approved by
the soil engineer. These materials should be non-expansive and granular in nature.
Adequate drains will be required behind the cut areas where the slope has been removed
and drained in a positive manner away from the building and into the cn-site drainage
system. The replacement should be done according to accepted eagineering practices
relative to proper and adequate compaction. This operation should be reviewed by a
representative of this office. in order to ensure that the work is completed according to
applicable standards.
The lower retaining structure should be replaced with an adequate masonry wall and footing
system placed at such a depth as to ensure the structural integrity of the wall against
overturning, as noted within the existing StiudViC.
Our final report wili be forthcoming; however, I hope this information will be adequate in
order to permit the Homeowners' Association to evaluate the conditions surrounding 1913-F
Alga Road and !he decision for re~edial repair to be undertaken without furthe: delay.
In closing, 1 wish to ir?dicaie that I reviewed this property in the 1970s wit11 similar drainag
control recommendations. At that time the repairs were considered to be excessive and too
expensive.
.., - . ...
Casitas de la Costa Homeowners’ Assn.
August 24, 1993
Page 4
Approximately 10 years later, American Geotechnical has reported the situation and made
recommendations which again were not followed by the Homeowners’ Association. It is now
August, 1993, approximalely two to three months away from a new rainy season and the
distress continues will1 little or nothing having been done to cxacerbate. .the ccrldition which
has been discussed herein. I hope that youi prudent evaluation of this informztion and the
conditions surrounding Building 19i3 be reviewed in its entirety to ensure that the dist:ess
described in this ir.terim report can be promptly corrected.
RCE 22096
cc: Wyman (2)
HOA (5 j
Leslic Lzonhart (2)
L -
" Y-Y . .. ~-
I I I
wc PATm
3 r
I
li~
"
"
"
"
I
;Et Dark Brown w/C)live clay silty clayey fine sands SC/CL
Bottom i3 6.5'
FIELD LOG
H' f-i
I
t
Date: 8-16-93 Field Rep.: CT
dJ Drill Rig: Hand Auger i2
BORW NO. H-3 SOIL DESCRIPTION I:n"rrP+P pnrp '{ I/y" SM Yellow Brown, Loose, Wet, SM
CC light Olive gray, soft, wet to saturated, CC/SC
CC Dark Brown, soft, saturated sc/cc
Bottom cd 8 1/2'
I Date: 8-16-93 Field Rep.: CT
Drill Rig: Hand Auger
H-2 BORWQ NO. SOL DESCRIPTION
Concrete core 3 1/2 'I
Olive gray, soft, very wet, CL
se. wet. silt" fine sand
Itefusal or concrete debris
1 PROJECT NAUZ Alga 1913 IFGURE HC.