Loading...
HomeMy WebLinkAbout1914 PALOMAR OAKS WAY; ; CB992016; Permit2RecI-Watêr Con. Re I '2 ddjl Reel /,r Cpn. Fee Payoff Fee FF PFF(CFDFund) License Tax J Tax'(CFDFund) , $600 iTraffi&-Irndt CIIJ Fun'd) $booOi fii1Z I U $0.00' PLUMBING TOTAL $000ELEqjtCAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee: Sewer Fee: $0.00 TOTAL PERMIT FEES $0.00 $0.00 $0.00 $2,967.00 $0.00 $0.00 - $0.00 - . $1,474.00 $0.00 $670.00 $69.00 $110.00 $75.50 $0.00 $2,354.58 $10,812.55 ? City of Carlsbad 07/09/1999 Commercial/industrial Permit Permit No: 0B992016 Building Inspection Request Line (760)438-3101 •t,. - •: - 'Job Address 1914 PALOMAR OAKS WY CBAD St 250 Permit Type: TI Sub Type: INDUST Parcel No: 2120920500 ' Lot #: 41 , . •' Status: ISSUED :.'Valuatiôn: $441,140.00 Construction Type:VN Applied:,, 05/26/1999 •." •. Occupancy Group: Reference #: . •. . Entered By:' RMA - .Projéct Title: INTERACT Plan Approved: '07/09/1999 5843 SF OFFICE,9912 SF WAREHOUSE & MEZZANINE Issued: 07/09/1999 Inspect Area Applicant Owner -. DESlGNCORP . CA-&-ASSDClATES L L C STE 175 ' C/O LARRYOQDWARD 4445 CEDROS 90 WILLOW CREK RD #400 SOLANA BEACH CA 92075 760 794-3222' 1721 07/09/99 000101 02 0 C—FRMT 9613.0 80 Total Fees: $10,812.55 2tal PaFnentsiQa Due: $9,630.80 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD#2Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size' AddI Pot. Water Con. Fee FINAL APPROVAL Inspector: Date: ( ' - Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of lees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. - CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 -I- FoRoFF!cE USE ONLY PERMIT APPLICATION PLAN CHECK NO EST q ~10ITY OF CARLSBADBUILDIN&DEPARTMENT 'J .2075Las'PaImêsDr.',CarI bad CA 92009 -.r--' , Ck P9posit- (760) 438-1161 — — :ted By___________________ te tJEcJNRMATIoN • Ic1I4 PoA2,4S IAJo( S*ic'- p49 CA Address (include Bldg/Suite #) Business Name (at this addre ),.. 41 Legal Desc iption . . Lot No.--.-- Subdivision Name/Number -, - _. Unit No. . • PhaeNo., I/ Total of units Al'4 515, Assessor's Parcel # Existing Use Proposed Use '- 1-%_ Description of Work.. , SQ. FT. #ofStôries . : # of Bedrooms :. #,ofBathrooms AC ift m palit 444 . c °7c 74 XW t7,4419: Name .. , Address - Y ...,City' - tite Z p Tilcphone # Fax # r3APLICANt D tcOnt f & cc, ntraci 0 o 'AIen? Ownr T'1 Name 'City .-. ., - -. - . - -Addro - - C t - stmo Zip Telephone '# --- - — RTW:'+,QWNER51 OWNEP Name -____ ___q_'2-' 1 Addreo Coy Stao Zip Telephone NAME ___. (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, impi Qe5is wits issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the c J11pr 5 Lucens11L?5 [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is e m xept therefrom and the basis for the a,Uëged 'axe m tion. Any vi latiçin of Section 7031.5 by any applicant for a permit subjects the applicant to a civilpenalty of not more than five hundred dollars ($50011. - ___Ni-- _ S0___4zs2-I4-236 -- - Name - . i--- - ,• --State/Zip -' . Telephone # ddress1 City State Liàense # •LicenseClas -___ I 1 City Business License* •_444 S ..c _ Sin L_ Designer Name -: ,.. - -, Address City • State/Zip ,Telephone State License # I •, . • . - : - .. - -, - - - -. T' - - iWorkers Compensation Declaration I hereby affirm und r penalty of perjury one of the following declarations 0 I haveand will maintain a certificate of consent to self insure tcr workers compen tion 's provided by Section 3700 of the Labor Code for the performance of t work for which this permit is issued. -- - Ihave and wifl.maintain workers', compensation, as required by Section 3700of the-Labor Code, for, the performanceof the work- for. viihichthis permit is issued. My worker's compensation insurance carrier and policy number are: -. -, .. , - . , •, , - - -- insijfa'ce Comp&ny 66k11I1%tl_1s'I19 e..9Cj)?Policy No. IJ DJ1$P5I34I9O2. Expiration Date_______________ -(THIS SECTION, NEED-NOT .BE COMPLETED IF THE-PERMIT IS FORONE HUNDRED DOLLARS I$100IOR LESS) - - • it D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not -employany person in any manner so,as to become subjt to th r er oni'pensation La of California — WARNING: - Fa!lur o - ecure rker comp sa' coverage is unlawful, end .shall subject an ernpIoyr t'ciminiI penalties anji civilirAs up to re htindred thousand dollars ($100 , in additi n t a f compensation, damages as provided for in Section 3706 of theLabolcode, ijterest end attorney's fees. SIGNATURE ____'' -..'- DATE ' ?f11- ILDERLARAJbJL — ___ - ( . il hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 -1,—as o,ner'of the property or rn'y employees withwages as jhiéir sole compensation, will'doth'e 'work ndthe structuré"is'not intended or offered for sale t(Sec 7044 Business and Professions Code:,The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided thatsuch improvements are not intended or offered for sale. If, however, the building orimprovement is sold-within one,year of.completion,..theowner-builder will havethe burden of,provingthat he did not build or improvefor the purpose of salà).-, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, -Business and Professions Code: The - Contraótor'iLicense Law does not apply' to' an Ow'iier f propert who builds -or improves thereon, 'and contracts for such projects with contractor(s) licensed :pursuant to the Contractor's License Law(. lam exempt under Section - Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D,'E 1 ; []NO ir 2 ,2. I (have / have nàtl signed an applicatiOn fOr a building'permit for the proposed work. ' . - ...........•. . - - - - - I have contracted with the following person .(fjrm).tp provide theproposed construction (include name I address J phone numbbr/ cdntactorsjicené ntmber): - I plan to provide portions of the work,but I have hired the following person-to coordinate,* supervise and provide the major work (include name /address/ phones ,number / contractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work)' -...--- . - .. --- . .. - :is'. - -• . PROPERTY OWNER SIGNATUE DATE • t IL _MITSEONLY, ,ls"he aplicáni 'or future' building 'occupant reuired to submit a business plan, acuteiS' hazardous mterials registration forndr risk manaä ertiandr'everition : program under Sections 25505, 25533 or 25534 of.the Presley'TennerHazardous Substance Account Act? .0 YES'D. NO -• - Is the applicant or future building occupant required to obtain a permit from the air pollution" control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000-feet of the outer boundary of a school site? 0 YES 0 NO • -.. - , - .• - • IF ANY OF THE ANSWERS ARE YES.A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUEDUNLESS THE APPLICANT HAS-MET OR IS MEETING ,THE REQUIREMENTS OF THE OFFICE OF EMERGENCYSERVICES AND THEAIR POLLUTION CONTROL DISTRICT: I hereby affirm that there is a construction lending agency for.the.performance of the,work for which this permit •od (Sec i097(i) Civil Code). LENDER'SNAME - _-•_'.-- _.,, ___________- 'LENDER'S ADDRESS _ '.•. _-•--. ___-- - Li AICCERRFICION - - - T - - certify thatl have read the' application and state that the above information is correct and that the information on the Ians is accurate; ,l agreetoicómp(y with all - - City -ordinances and State Iaws relating to building construction. I hereby authorize representatives of the Cit' of arlsbad to enter- upon the,above mentioned property for inspection purposes. I ALSO AGREE -TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF. CARLSBAD GAINST ALL LIABILITIES, - .'JUDGMENTS, COSTSAND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE-OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit isrequired for excavations over 5 0 deep and demolitiont or construction of structures over '3 stories in height - EXPIRATION: Every permit issued he BuildingOfficial underih provisionsof his Ccde hallexpird by Iimitatin.ndbecome null ard'vdid.if,the buildingor - work authorized by such permit isfy . r " t ommencd within ys the date of ch permit or ifthe building or work authorized by such permit is suspended '1 orabadoned at anytime after- theoIco?nr4nid foi a nod f days (S 106.4.4 Uniform'Buildin Code). '' - ,. ..'.. • - APPLICANT S SIGNATURE * DA %TE MAY" WHITE File YELLOW Applic nt PINK Finance City of Carlsbad Inspection Request L : J For: 8/18/99 Permit# CB992016 Inspector Assignment: DH Title: INTERACT Description: 5843 SF OFFICE,9912 SF WAREHOUSE & MEZZANINE Type: TI Sub Type: INDUST Phone: 6198430649 Job Address: 1914 PALOMAR OAKS WY Suite: 250 Lot 41 Location: APPLICANT DESIGNCORP Owner: C A C ASSOCIATES L L C Remarks: PM PLEASE Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: LYNN Entred By: CHRISTINE Act Comments Inspection History Date Description Act lnsp Comments 8/13/99 19 Final Structural CO OH LOWER KIT COUNTER TO 34" 8/13/99 29 Final Plumbing CO DH MOVE SPRINKLER IN ELECTRIC RM 8/13/99 39 Final Electrical CO DH FIRE CAULK IN ELECTRIC RM 8/12/99 89 Final Combo NR Dl-I FINISH HARDWARE, DOORS 7/30/99 14 Frame/Steel/Bolting/Welding NR DH INSTALL SUPPLY & RETURN GRILLS 8/4/99 34 Rough Electric AP DH AP ON 8/3/99 ABOVE T-GRID 8/4/99 44 Rough/Ducts/Dampers AP DH AP ON 8/3 ABOVE T-GRID 8/3/99 84 Rough Combo AP OH T-GRID 7/28/99 17 Interior Lath/Drywall AP OH 7/26/99 17 Interior Lath/Drywall PA OH NOTED ON CARD 7/22/99 24 Rough/Topout AP DH 7/19/99 14 Frame/Steel/Bolting/Welding CA OH 7/19/99 34 Rough Electric CA OH 7/16/99 14 Frame/Steel/Bolting/Welding AP DH WALLS 7/16/99 34 Rough Electric AP DH 7/13/99 21 Underground/Under Floor AP DH 7/12/99 21 Underground/Under Floor CA DH City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: Date: 8/12/99 Permit #: CB992016 Permit.Typ: TI Project Name: INTERACT Sub Type:, INDUST 5843 SF OFFICE,9912 SF WAREHOUSE & MEZZANINE Address: 1914 PALOMAR OAKS WY Lot: 41 Contact Person: LYNN Phone: 6198430649 Sewer Dist: CA Water Dist: CA Inspected By:, Date Inspected: QQ Approved: b Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved:_ Disapproved: Comments: EsGil Corporation in Partnership with government for Building Safety DATE: 7/7/99 0 P-P NT 0 JURIS. JURISDICTION: Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 99-2016 SET: III PROJECT ADDRESS: 1914 Palomar Oaks Way Suite 250 PROJECT NAME: INTERACT T.I. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. F-1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: fl Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Candace Merritt Telephone #: Date contacted: h (by: D'( ) Fax #: Mail Telephone Fax In Person REMARKS: 1-City-t-verify-that the-path-of-travel from the handicapped-parking-spaceiQtbe remodel are nts. 2. The applicant —carr ed the approved pn back to tha city.(O.K. per Mr hand Pain By: David Yao Enclosures: Esgil Corporation 0 0 GA j MB j EJ IJ PC log tmsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnership with government for Wui(ing Safety DATE: 7/1/99 U APPLICANT JURIS. JURISDICTION: Carlsbad REVIEWER U FILE PLAN CHECK NO.: 99-2016 SET: II PROJECT ADDRESS: 1914 Palomar Oaks Way Suite 250 PROJECT NAME: INTERACT T.I. ElI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for-your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Candace Merritt 444 S. Cedros Studio 175 Solona Beach CA 92075 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LII REMARKS: By: David Yao Enclosures: Esgil Corporation GA UMB flEJ F-1 PC 6/23 trnsmtLdot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad 99-2016 II 7/1/99 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 99-2016 PROJECT ADDRESS: 1914 Palomar Oaks Way Suite 250 SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 6/23 7/1/99 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code,' the approval of the 'plans does not permit the violation of any state, county or city law. 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760)438- 1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. A. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. Carlsbad 99-2016 II 7/1199 The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copybf the - prior .coriectión Iist,-. we have enclosed those pages containing the outstanding corrä'ctidhs. Please contact me if you have any questions rèaFdiihese items. Please indicate here if any changes have been made to the plansthat are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes No Carlsbad 99-2016 II 7/1/99 1. City to verify that the path of travel from the handicapped parking space to the remodel area comply with all the current disabled access requirements. PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Glen Adamek ENERGY CONSERVATION The lighting energy design (LTG-forms) shows the conditioned floor area is only 5,843 square feet. The ENV-1 and MECH-1 forms shows the conditioned floor area is 6,591 square feet. Please correct. On the plans clearly show the 9 inch thick concrete walls and R-1 9 roof insulation, as per the energy design. The Lighting energy design on the LTG-2 on sheet E-213 does not show the lighting in the conditioned Manufacturing area. Please correct. On the electrical plans show the light fixtures as per the energy design. The 2 X 4 light fixture symbol used on the lighting plans does not match the Legend. Please correct. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131(d). Complete the "Mandatory Automatic Controls" section of LTG-1 part 2 of 2 on sheet E-213 and detail the lighting control system to be used for automatic shut-off controls. Please correct the light switching to provide the required bi-level lighting controls as per Title 24, Part 6, Section 131(b). Show the daylit areas and required daylit area lighting controls for lighting in daylit areas. Title 24, Part 6, Section 131(c). Please correct the light switching in the first floor Conference and Open Area. The corrected, completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. The ENV-1 part 2 of 2, MECH-1 part 2 of 3 and the MECH-1 part 3 of 3 are missing from the plans and the data from the forms is not in schedules on the plans. 15. The Documentation Author and the Principal Lighting Designer must sign the LTG-1 form. Carlsbad 99-2016 II 7/1/99 17. Complete energy plan check will be done when complete corrected energy designs are provided. Note: If you have any questions regarding this plumbing, mechanical and energy plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. EsGil Corporation In Partnership with government for Building Safety DATE: 6/7/99. U APPLICANT JURISDICTION: Carlsbad U PLAN REVIEWER U FILE PLAN CHECK NO.: 99-2016 SET:I PROJECT ADDRESS: 1914 Palomar Oaks Way Suite 250 PROJECT NAME: INTERACT T.I. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Candace Merritt 444 S. Cedros Solana Beach CA 92075 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person LII REMARKS: By: David Yao' Enclosures: Esgil Corporation GA Z MB EJ Li PC 5/27 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (619)560-1468 • Fax (619) 560-1576 Carlsbad 99-2016 6/7/99 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 99-2016 JURISDICTION: Carlsbad OCCUPANCY: B/S-i USE: office/ warehouse TYPE OF CONSTRUCTION: V-N ACTUAL AREA: 15755 sfT.I. ALLOWABLE FLOOR AREA: STORIES: 2 HEIGHT: ISPRINKLERS?: ? REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 6/7/99 OCCUPANT LOAD: -78 DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/27 PLAN REVIEWER: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1994 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot Carlsbad 99-2016 6/7/99 Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Indicate the use of all spaces adjacent to the area being remodeled or improved. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 807. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 708.(if applicable) Storage areas exceeding 1000 sq. ft. in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. Section 309.2.2.(Is this building sprinkler?) . CITY OF CARLSBAD SUPPLEMENT Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official. (City Policy) All roof-mounted equipment shall be concealed from view. Provide structural detailing for the screening. If it is desired to appeal the requirement for upgrades regarding disabled access provisions, please fill Out the enclosed "Application for Unreasonable Hardship" and submit it to the Building Department. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA Carlsbad 99-2016 6/7/99 92009, (760) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . MISCELANEOUS Please refer to the following corrections for mechanical, plumbing, energy and electrical items. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are nota result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes El No El The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. PLUMBING, MECHANICAL AND ENERGY CORRECTIONS PLAN REVIEWER: Glen Adamek The licensed designer must sign each sheet of the plans. Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. a) Clearly show types of hazardous material is being stored or used. Provide a list of the proposed hazardous materials as per the types in UBC, Tables 3-D, and 3-E. Provide the material safety data sheets (MSDS). Carlsbad 99-2016 6/7/99 Clearly show the amounts of each type of hazardous material to be stored and in use. Clearly show where in the buildings each type of hazardous material is being stored or used. MECHANICAL (1994 UNIFORM MECHANICAL CODE) Detail required roof access ladder to roof mounted HVAC equipment. UMC, Section 321.8 In Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or Ill-A liquids are used (in any amount), mechanical exhaust shall be provided sufficient to produce six air changes per hour. Such mechanical exhaust shall be taken from a point at or near the floor. UBC, Section 1202.2.2. "Equipment, machinery or appliances which generate finely divided combustible waste or which use finely divided combustible material shall be equipped with an approved method of collection and removal." UBC, Section 306.8 ENERGY CONSERVATION Provide plans, calculations and worksheets to show compliance with current energy standards. Provide a copy of the envelope energy designed approved with the shell building design. Envelope energy design was not required for the shell building. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. The Lighting energy design does not show the lighting in the conditioned manufacturing area. Please correct. On the electrical plans show the light fixtures as per the energy design. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131(d). Show bi-level lighting controls as per Title 24, Part 6, Section 131(b). Show the daylit areas and required daylit area lighting controls for lighting in daylit areas. Title 24, Part 6, Section 131(c). The corrected, completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. Carlsbad 99-2016 6/7/99 The Documentation Author and the Principal Envelope Designer must sign the ENV-1 form. The Documentation Author and the Principal Lighting Designer must sign the LTG-1 form. The Documentation Author and the Principal Mechanical Designer must sign the MECH-1 form. Complete energy plan check will be done when complete corrected energy designs are provided. Note: If you have any questions regarding this plumbing, mechanical and energy plan review list please contact Glen Adämek at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. ELECTRICAL PLAN REVIEW 1993 NEC PLAN REVIEWER: MORTEZA BEHESHTI Submit complete service and feeder one line diagram. NEC 215-5. Show the available fault current (Isc) from the serving utility co. and at the equipment where Isc exceeds 10,000 amps. Show the ampere interrupting capacity (AIC) ratings of the service and subservice equipment. NEC 110-9, 230-65. Show or note on the plans the method used to limit fault currents to 10,000 amps on branch circuits. Show the grounding system required for each building, structure, or service. NEC 250- 80(a), 81(c). Show the grounding electrode conductor size and wire type (AL/CU). NEC 250- 94. Show the l nearest electrode" used for each transformer secondary ground system (i.e., building steel, cold water pipe). NEC 250-26(c). Submit load calculations. Include long continuous loads (LCL) and the largest motor loads. NEC 220. Carlsbad 99-2016 6/7/99 Indicate main service size (amperage rating) and the total load demand on the service. Show on the plan the location of the service(s) NEC 110-16, 230-2. Submit complete panel schedule(s). Provide GFI protected receptacle(s) in the bathrooms. NEC 210-8 Provide multiple switch light controls so that the lightingcan be reduced by one half in a uniform pattern. The switches must be located within sight of the lights which they control. CBC Title 24, Sec 131 a-b Show exit signs on the lighting plan(s) at all required exits and specify them as being self-luminous or having a second source of power (battery or generator). This is required when two exits are required per the UBC. UBC 1013.4 and NEC 700-16. In all occupancies where the exit system serves 100 or more occupants, provide a minimum of 1 foot-candle of emergency illumination at the floor level and specify a second source of power for the emergency illumination (battery or generator). UBC 1012.2 & NEC 700-16. Note: If you have any questions regarding this electrical plan review list please contact Morteza Beheshti at (619) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL TITLE 24 DISABLED ACCESS REQUIREMENTS . REMODELS, ADDITIONS AND REPAIRS City to verify that the path of travel from the handicapped parking space to the remodel comply with all the current disabled access requirements. SANITARY FACILITIES 2. Note that the doorways leading to sanitary facilities shall be identified, per Section 1115B.5, as follows: a) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per Section 1117B.5.9. Carlsbad 99-2016 6/7/99 . SINGLE ACCOMMODATION FACILITIES Revise plans to show a sufficient space in the toilet room for a wheelchair to enter the room and close the door, per Section 111 5B.7.2. The space is required to be: a) Doors are not-permitted to encroach into this space by more than 12 inches. Show that the water closet is located in a space, per Section 111 5B7.2, which provides: a) A minimum side clearance of either: i) ~28" from a fixture. GENERAL ACCESSIBILITY REQUIREMENTS SIGNAGE Where permanent identification is provided for rooms and spaces, raised letters shall also be provided and shall be accompanied by Braille. Section 111 7B.5. Provide a note on the plans stating that the signage requirements of Section 111713.5 will be satisfied. END OF DOCUMENT Carlsbad 99-2016 6/7/99 VALUATION AND PLAN CHECK FEE. JURISDICTION: Carlsbad PLAN CHECK NO.: 99-2016 PREPARED BY: David Yao DATE: 6/7/99 BUILDING ADDRESS: 1914 Palomar Oaks Way Suite 250 BUILDING OCCUPANCY: B/S-i TYPE OF CONSTRUCTION: V-N BUILDING PORTION BUILDING AREA .(ft.2) VALUATION MULTIPLIER VALUE ($) Office 5843 Warehouse 9912 Air Conditioning Fire Sprinklers TOTAL VALUE 441140 (per city) E 199 UBC Building Permit Fee Bldg. Permit Fee by ordinance: $ 1818.08 199 UBC Plan Chebk Fee Plan Check Fee by ordinance: $ 1181.75 Type of Review: Complete Review Structural Only L Hourly J Repetitive Fee Applicable fl Other: Esgil Plan Review Fee: $ 945.40 Comments: Sheet I of I macvalue.doc 5196 Carlsbad 11F0 bli( BUILDING PLANCHECK CHECKLIST DATE: (o I ) PLANCHECK NO.: CB 39 O I(o BUILDING ADDRESS: 111 ?CU onta-&. OS \tcu so PROJECT DESCRIPTION: 1U 13ub 0ut' ASSESSOR'S PARCEL NUMBER: - I 2.. o EST. VALUE: L/c/1 It/o ENGINEERING DEPARTMENT ri:J JJsI'kiI The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. U Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please s attached report of deficiencies marked ith 0. ke necessary corrections to plans or sped for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By 41J 1 Date: By: Date: By: Date:. FOR.OFFICIALUSE ONLY By G.AUTHORIZATION TO ISSUE WILDING PERMIT ATTACHMENTS Li Dedication Application LI Dedication Checklist Li Improvement Application LI Improvement Checklist Li Future Improvement Agreement LI Grading Permit Application LI Grading SUbmittal Checklist Li Right-of-Way Permit Application J Right-of-Way Permit Submittal Checklist and Information Sheet Li Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name:. KATHLEEN M. FARMER City of Carlsbad Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Phone: (619) 438-1161, ext. 4374 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: A-4 576 • (760) 438-1161 • FAX (760) 431-5769 BUILDING PLANCHECK CHECKLIST SITE PLAN 1 ST/ 2NDI 3RDI Ii 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Property Lines Existing & Proposed Structures E. Easements Existing Street Improvements F. Right-of-Way Width & Adjacent Streets G. Driveway widths 2. Show on site plan: A. Drainage Patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography 3. Include on title sheet: Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. • EXISTING PERMIT NUMBER DESCRIPTION DISCRETIONARY-APPROVAL COMPLIANCE Ii Q a 4a. Project does not comply with the following Engineering Conditions of approval for ProjectNo._______________________________________________ U U U 4b. All conditions are in compliance. Date: \ASPALMAS\SYSLIBRARV\ENG\WORDDOC$\CHKLST\BuiIdifl9 Pland,eck Cktst BP000I Form KF.doc Rev. 9/3/97 BUILDING PLANCHECK CHECKLIST DEDICATION REQUIREMENTS 1ST/ 2ND/ 3RDJ 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $_, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 1,4fl x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: - IMPROVEMENT REQUIREMENTS LI 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $_, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: LI LI LI 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $_________________ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: \\LSPALMAS\SYSUBRARYENG\WORD\DOCS\CHKLSTBuiIdbig Plaflcfleck Cwt OP0001 Form KF.doc Rev. 9/3/97 BUILDING PLANCHECK CHECKLIST ndI 3rdl cl Li Li 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: Li Li 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. Li Li Li Li Li Li Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Gradina Permit must be issued and rouah aradina approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: -- Date: Li Li Li Li Li Li Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) No Grading Permit required. Li Li Li 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS Li Li Li 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for: \LA$PALMAS\SYS\LIBRARVENG\WORO\DOCS\CHKLS1'BuidIng Plantheck Cklst BP000I Form KF.doc Rev. 913197 BUILDING PLANCHECK CHECKLIST 1st/ 2' 3rdl 9. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. LI 10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for assistance. Industrial Waste permit accepted by: Date: LI 11. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES). permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. LI LI LI 12. LI Required fees are attached . LI No fees required (1I LI LI 13. Additional Comments: Pla,thedc Cklst 6P0001 Form KFdoc Rev. 9/3/97 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant. O Calculation based on building plancheck plan submittal. Address: ( I'4 PI-k V'-O- OCLI<S \4&1Idg. Permit No. --o v Prepared by: Date: Checed by: Date: ( (-t (c- EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq. Ft./Units: EDU's: Types of Use: Sq. Ft./Units: EDU's: ADT CALCULATIONS: List types and square footages for all uses. Typeè of Use: Sq. Ft./Units: ADT's: (fl Types of Use: Sq. Ft./Units: ADT's: FEES REQUIRED: WITHIN CFD: 0 YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) 0 NO lfi. PARK-IN-LIEU FEE PARK AREA & #: FEE/UNIT: X NO. UNITS:_______ = $____________ 2. TRAFFIC IMPACT FEE q ADT's/UNITS: X FEE/ADT: =$ ZONE TRANSPORTATION ADT'S (ol X $10 .=$ -7 0. 0-3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 DIST. #2 DIST. #3 ADT's/UNITS: X FEE/ADT: $____________ 4. FACILITIES MANAGEMENT FEE ZONE:________ UNIT/SQ.FT.: X FEE/SQ.FT./UNIT: =$ _- 5. SEWER FEE 3 PERMIT No. I.2-'? EDU's: X. FEE/EDU:J- =s___________ BENEFIT AREA: DRAINAGE BASIN:_______ EDU's: X FEE/EDU: = $ 6. SEWER LATERAL ($2,500) = $ _.- 7. DRAINAGE FEES PLDA : HIGH /LOW______ ACRES: X FEE/AC: = $____________ TOTAL OF ABOVE FEES*:$ *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. P:DOCS\MISFORMSFEE CALCULATION WORKSHEET REV 4/29/99 Ww fZ L/~000 _ - 3q9 - PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST tr Plan Check No. CB Address(1t 4 vtt Octl'i- Planner Y.CkCVJ(Ar& 1-iiredy Phone (619) 438-1 161, extension 43? APN: OL (01 —D°.--O • Type of Project & Use:o 1C/C tu0Jet Project Density: DU/AC j Zoning: P-_4 General Plan: Pt Facilities Management Zone: _________ CFD 1inIn,,t #Date of participation: Remaining net dev acres:______ Circle One > >. > (For non-residential development: Type of land used created by this permit:__________________________________________________ 1771 Legend: Item Complete Item Incomplete - Needs your action Environmental Review Required: YES NO -Y TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. / Conditions of Approval: Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. Elf_°tl-o(.o OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:____________________________________________________ Coastal Zone Assessment/Compliance . . Project site located in Coastal Zone? YES____ NO-k CA.,Coastal Commission Authorit'y? YES * NO____ I If California Coastal Commission Authdrity: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 - Determine status (Coastal Permit Required or Exempt): • Coastal Permit Determination Form älreàdy completed? YES NO____ - If NO,complete Coastal Permit Determination Forn now. Coastal Permit Determination Log # - • . J. . •• - - * Follow-Up Actions: •- - ,-. - •- * 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (atrninimurn Floor Plans). • :. . . -. * V * ; .2) Complete coastal, Permit Determination Log as needed. E IncIusionäryHousingFee required: YES NO)( (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) - Data Entry. Completed? YES NO - (A/P/Ds, Activity Maintenance,, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!) Site Plan: - - Provide a fully dimensional site plan drawn to 'scale; Show: North arrow, 'property lines, easements, existing and proposed structures, streets, existing Street improvements, right-of-way width, dimensional setbacks and existing topographical lines. * Provide legal description of property and assessor's parcel number. Zoning: ' Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Accessory structure setbacks: Front: Required Shown Interior Side: Required ' Shown Street Side: Required Shown Rear: Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required Shown Height: Required Shown hit ,1'fk- iee jr, p er'enie13 411, uses n 4')..,, b id 'n , icji4in, V&eai 04 Parking: Spaces Requird 1S3 Shown Guest Spaces Required Shown E Additional Comments(I) ThUP. (A co- 1)1/A1 AAA t(m(1 -\4L IL4tAan Iitc \iie441o. o -f (tx,c eQu13• Crtevw c Lit tk,Lc P,Yj*,42 (LJt?,4- Yr'taj 1. U1 A. LI re e .. cl. 1bL) (düs5 - as tit"&,fecl IL Ie,dio,i. Lliup. Vi Cec To' L1 O C& (( 1 tJ , OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 4L&d3—) DATE 'liON B—B )T 10 SCALE cast / CROUNDs ATRItIV. GA1E 1000* DRAIN fffiEsiO Ow AM liON C—C T 10 SCALE / .casr.GROM -. GRATE ANDDOm DRAIN: :.Pu / 1 AMP I' I -: AI OWNER C A C ASSOCIATES LLC, A CALIFORNIA LIMITED LIABILITY COMPANY 9820 WILLOW. CREEK ROAD, SUITE 400 SAN DIEGO, CALIFORNIA 92131 SUBDA VIDER C A C ASSOCIATES LLC, A CALIFORNIA LIMITED LIABILITY COMPANY 9820 WILLOW CREEK ROAD, SUITE 400 SAN DIEGO, CALIFORNIA 92131 ic ENGINEER DOUGLAS lfi, MASSON DATE MASSON AID 'ASSOCIATES, INC. 200 EAST: WASHINGTON AVENUE, SUITE 200 ESCONDIDO, CALIFORNIA 92025-1816. (760) 741-3570 DATE,,-0'F- PREPARATION SEPTEMBER 5,-1997 REVISED: 12-17-97 NOTES.. ASSESSOR tRARCEL..NUMBER: 212-092-05 £AMINOFV1DA ROBLE, CARLSBAD, CALIFORNIA SITE ACREAGE(-4.645" AC EXIS11NGZONING:.PM. GENERAL PLAN'DESIGNAllON: P1 EXISTING" LANDUSE: VACANT PROPOSED LAND 'USE: 2 INDUSTRIAL LOTS .. - ' - .4. TOTAL .BUILDINGCOVERAGE: 27% BUILDING SOU 'ARE F:OOTAGE: 65,967 SQUARE FEET LANDSCAPECOVERAGE:'9% - NUMBER '.OF':PARKING.SPACES REQ .. UIRED -1 'SPACES' - NUMBEROE-RARKINGSPACES PROV1DED: 195:SPACES. 'REGULAR PARKING-SPACE DfMENSIONS:1885!/!20'i8.5" COMPACT PARKING:-SPACE DIMENSIONS::..15 x8'-- .i AVERAGE DAILY TRAFFIC: :70Z1 ,. ". '.• .•-,_j - •. .•• -- --,, •.. . I TTI'. : SEWER: CARLSBAD MUNICIPAL WATER -DISTRICT ('I-1flrW fl,TPlr'T• ('API PAI 0-75 MW DITCH OR 4". ATRIUM GRATE AND DOVIN DRAIN AS SHOWN ON PLAN 1 -irc SQc 1Or(L- 5S4 7 '1tLek- 748 PS. 0 CCU Ji2•. F?z k cCeS PL46 J 19Q /rIsbad Fire Department 990232 /2560 Orion Way Fire Prevention Carlsbad CA 92008 (760)931-2121 Plan Review Requirements Category: Building Plan Date of Report: 06/01/1999 Reviewed by: Name: CANDACE MERRITT Address: #175 444 S CEDROS City, State: SO LANA BEACH CA Plan Checker: Job #: 990232 Job Name: Interact - CB992018 Job Address: 1914 Palomar Airport Rd Ste. or Bldg. No. 250 Approved The item you have submitted for review has been approved. The approval is based on plans, information and I or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments - attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. O Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the - applicable codes and I or standards. Please review carefully all comments attached. Please resubmit the necessary plans and I or specifications to this office for review and approval. Review 1st 2nd 3rd Other Agency ID ED Job # 990232 ED File # i.Hzardou5 Materials I4 SAN DIEGO REGIONAL "øc C" HAZARDOUS MATERIALS QUESTIONNAIRE Management Division suit, up ass Bilge Business Name Contact Person Telephone L-L i-\AhJ Js - 44ô- 1474 Mailing Address City State Zip Plan Filet ICA Site Address City State Zip Plan Filet 'I 14 rAL-0 PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION: OCCUPANCY CLASSIFICATION Indicate by circling the Item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Explosive or Blasting Agents 4. Flammable Solids 7. Pyrophorics 10. Cryogenics 13. Corrosives Compressed Gases S. Organic Peroxides 8. Unstable Reactive. 11. Highly Toxic or Toxic Materials 14. Other Health Hazards Flammable or Combustible Liquids 6. Oxidizers 9. Water Reactive. 12. Radioactive. PART It: COUNTY OF SAN DIEGO HEALTH DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION: CONTINGENCY PLAN REVIEW: If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Management Division, 1255 Imperial Avenue, 3rd Floor, San Diego, CA 92186-5261. Telephone (619) 338-2222 prior to the issuance of a building permit. FEES MAY BE REQUIRED Yes No Is your business listed on the reverse side of this form? Will your business dispose of Hazardous Substance. or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet or carcinogens/reproductive toxins in any quantity? CR Will your business use an existing or install an underground storage tank? S-= # Will your business store or handle Acutely Hazardous Material.? OFFICE USE ONLY 0 RMPP Exempt Date Initials RMPP Required Date Initials 0 RMPP Completed Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes, applicant must contact the Air Pollution Control District, 9150 Chesapeake Drive, San Diego, CA 92123. Telephone (619) 694-3307 prior to the issuance of a building permit. YES NO Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution Control District Permit Categories, on the reverse side of this form? (ANSWER ONLY IF QUESTION 1 IS YES.) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12) as listed in the current Directory of School and Community College Districts, published by the San Diego County Office of Education and the current California Private School Directory, compiled in accordance with provisions of Education Code Section 331907 rietly aescribe nature of the intended business activity: Name of Owner or Authorized Agent: kl002 V JA2-c T- LL Agent: I de and correct. Signature of Owner or(Auz that to the best of my knowledge and belief the responses made herein are true _________________________________ Date: MA( 17 Vt99 Do not write below this Tine FIRE DEPARTMENT OCCUPANCY CLASSIFICATiON:_____________________________________________________________________ BY: Date:_______________________________________ EXEMPT FROM PERMIT REQUIREMENTS COUNTY-HMMD APCD APPROVED FOR BUILDING PERMIT BUT NOT OCCUPANCY COUNTY-HMMD APCD APPROVED FOR occupANcy COUNTY-HMMD APCD Eaviroamciitai Health Servcca . coimly of Sim Diego DHS:HM-9 171 (6/92) Deparftociet of Health Screiccs