HomeMy WebLinkAbout1915 CALLE BARCELONA; 135; CB032562; Permit.-N Ij
1 1-05-2003
Job Address:
Permit Type: Parcel No: Valuation:
Occupancy Group:
Project Title:
Applicant:
JAKE WEBSTER
STE H 1327 POST AV 90501
31 0 328-6300
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Building Inspection Request Line (760) 602-2725
Commercialllndustrial Permit Permit No: CB032562
191 5 CALLE BARCELONA CBAD St: 135
TI Sub Type: COMM Lot#: 0 status: $300,420.00 Construction Type: NEW Applied:
Reference #: Entered By:
Z GALLERIE-10,014 SF SHELL TO Plan Approved:
RETAIL Issued: Inspect Area:
Plan Check#:
Owner:
ISSUED 0911 712003
RMA
1 1l0312003
1 1 /03/2003
83.00 U/05/03 0002 01. 02
CGB 593.6 * 37
Building Permit
Add'l Building Permit Fee Plan Check Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee LFM Fee Bridge Fee
BTD #2 Fee
BTD #3 Fee Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee
$1,165.64 $0.00 $757.67
$0.00
$0.00
$63.09 $0.00 $0.00 $0.00
$0.00
$0.00 $0.00 $0.00
$0.00
$0.00
$0.00
$0.00
Meter Size
Add'l Recl. Water Con. Fee Meter Fee SDCWA Fee
CFD Payoff Fee
PFF
PFF (CFD Fund) License Tax
License Tax (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund) PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees
TOTAL PERMIT FEES
$0.00 $0.00 $0.00
$0.00
$5,467.64
$0.00
$0.00
$0.00
$0.00
$0.00
$1 18.00 $60.00
$42.00
$0.00
$0.00 $0.00 $0.00
$7,674.04
Total Fees: $7,674.04 Total Payments To Date: $757.67 Balance Due: $6,916.37
Date: Clearance: -q 6 *
NOTICE: Please take NOTICE that approval of your project includes the'lmpcktion" of f&s, dedications, reservations, or other exactions hereafter collectively
referred to as "feedexactions." You have 90 days from the date this permit was issued to protest imposition of these feedexactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
IT APPLlCATl
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck. Deposit
Business Name (at this address; Address (include BldgISuite #)
Legal Description Lot No.
a 6~116w&
Total # of units
St& d€ t3s-
mm Anrr;'&
Subdivision NamelNumber
&LL &hwioufl
Assessor's Parcel # Existing Use Proposed Use
E7 8 53 Description of Work SO. FT. #of Stories # of Bedrooms CG$pf Bathroom
ec. 7031.5 Business and Professions .'? issuance, also requires the applicant for such permit to file a signed statement that he IS licensed pursuant to the provisions of the Contractor's License Law 9 [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
pption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [85001).
3-0 tRnoM-p4 bn/rW/( OTWC5d %k A5 -7(s k-4 73,ALdEIC c- 5 34 9 /mXK%F' 72 b 622-2 r3-d city Statelzip Telephone # Address 8 78 Z License Class 6 City Business License # (2 { 6 7 67
ner Name Address City State/Zip Telephone
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
1 a I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
of the work for which this permit is issued.
issued. My worker's compensation insurance carrier and policy number are:
a644 Insurance Company TC P OF AM Policy NO. 3 z 5-q~ L Expiration Date 4- 1- 2 6of c /
THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
r
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0
1.
2.
3.
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number / contractors license number):
Business and Professions Code for this reason:
UNO
4.
number I contractors license number):
5.
of work):
PROPERTY OWNER SIGNATURE DATE
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number I type
PLETE THIS SIE
Is the applicant or f
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES e NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
0 YES &NO
YES @ NO
re is a construct
LENDER'S NAME LENDERS ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply wlth all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES.
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE &fl/pn/ &?z- DATE
. .
c
WHITE: File YELLOW: Applicant PINK: Finance
r L
Clty Df Carlsbad
Final Building lnsnection
Dept: Building Engineering Planning CMWD St Lite
Plan Check It:
Permit #: CEO32562
Project Name: Z GALLERIE-10,014 SF SHELL TO
RETAIL
Address: 191 5 CALLE BARCELONA #135 Lot:
Fire
Date:
Permit Type:
Sub Type:
0
02/24/2004
TI
COMM
Contact Person: WES HARPER Phone: 5209776541
Sewer Disk Water Dist: ..........................................................................................................................................................
/ Date Inspected: d7/& Approved: Disapproved:
Date
By: Inspected: Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved: ...........................................................................................................................................................
Comments:
Inspection List
Permit#: CB032562 Type: TI COMM Z GALLERIE-10,014 SF SHELL TO
RETAIL
Date Inspection Item Inspector Act Comments
02/24/2004 89
02/24/2004 89
0211 312004 89
0211 312004 89
0211 112004 89
0211 It2004 89
02/09/2004 84
02/06/2004 84
02/03/2004 84
01/28/2004 14
0 1 /28/2004 1 7
01 /28/2004 24
01/28/2004 39
01 /27/2004 17
01 /27/2004 39
01/23/2004 14
01 /23/2004 34
01 I1 312004 18
12/31/2003 14
12/31/2003 17
12/30/2003 17
12/23/2003 16
12/23/2003 17
1211 912003 17
1211 912003 34
1211 912003 44
1211 712003 14
1211 712003 34
1211 712003 44
1211 512003 14
1211 512003 24
1211 512003 34
1211 112003 14
1211 112003 24
1211 112003 34
1211 012003 84
12/09/2003 14
12/04/2003 17
12/02/2003 11
12/02/2003 17
1 1/26/2003 17
1 1/25/2003 1 1
1 1 /24/2003 1 1
1 1 I2412003 14
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Final Combo
Rough Combo
Rough Combo
Rough Combo
FramelSteellBoltingNeldin
Interior LatWDrywall
Roug hfropout
Final Electrical
Interior LatWDrywall
Final Electrical
Frame/Steel/BoltingNeldin
Rough Electric
Exterior Lath/Drywall
Frame/SteeI/Bolting/Weldin
Interior LathIDrywall
Interior LathIDrywall
Insulation
Interior Lath/Drywall
Interior LathIDrywall
Rough Electric
RoughlDuctsIDarnpers
Frame/SteeVBolting/Weldin
Rough Electric
Rough/Ducts/Dampers
FramelSteellBoltingNeldin
Roughflopout
Rough Electric
FramelSteeVBoltingMIeldin
Roughfropout
Rough Electric
Rough Combo
Frame/SteeI/Bolting/Weldin
Interior LathIDrywall
FtgIFoundationlPiers
Interior LathIDrywall
Interior LathIDrywall
Ftg/Foundation/Piers
Ftg/Foundation/Piers
FramelSteellBoltingNeldin
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
TP
TP
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
PS
AP
RI
RI
co
RI
co
PA
co
co
wc
AP
wc
co
PA
NR
AP
AP
AP
AP
AP
AP
AP
co
AP
AP
AP co
co
co
AP
AP
AP
co
co
co co
PA
PA
AP
PA
AP
AP co co
AM PLEASE
OK’TO STOCK ONLY
T-BAR
SPLAY WIRE NOT 45 DEGREE ANGLE
T-BAR
COMPLETE
EMR
2 FLYING CEILING
SUPP. GYP CElL
@ FIRE DAMPER
BACK OF HOUSE
WALLS SALES AREA
CONDUIT SALES AREA
CEILINGS (SEE NOTICE ATTACHED)
BACK OF HOUSE
NO FIRE APPROVAL
FRONT AREA
NOTED ON PLANS
@ WALK OFF AREA
NORTH WALL
PATCH BACK
Tuesday, February 24,2004 Page 1 of 2
# 1
11/24/2003 34 Rough Electric
1111 912003 17 Interior Lath/Drywall
1111 912003 21 Undergroundmnder Floor
11/17/2003 17 Interior Lath/Drywall
1 1 /17/2003 22
1 1/17/2003 31 Underground/Conduit-Wirin
11/13/2003 17 Interior Lath/Dtywall
Sewerwater Service
Tuesday, February 24,2004
PS PA COLUMN & D-WALLS
PS PA ABOVE TJI S PREM WALLS
PS AP
PS PA
PS co
PS AP
PS PA SOUTH WALL & EAST WALL TO
BOTTOM OF TJI
Page 2 of 2
City of Carlsbad Bldg Inspection Request
For: 02/24/2004
Permit# CB032562 Inspector Assignment: PS
Title: 2 GALLERIE-10,014 SF SHELL TO
Description : RETAIL
Type: TI Sub Type: COMM
Job Address: 191 5 CALLE BARCELONA
Suite: 135 Lot
Location:
APPLICANT JAKE WEBSTER
Owner:
Remarks: AM PLEASE
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
0
Phone: 5209776541
lnspecto
Requested By: WES HARPER
Entered By: CHRISTINE
Associated PCRs/CVs
PCR04010 ISSUED Z GALLERY REV DRYWALL CEILING
InsDection Historv
Date
02/13/2004
02/11/2004
02/09/2004
02/06/2004
02/03/2004
0 i/2812004
0 1/28/2004
01 /28/2004
01/28/2004
01/27/2004
01/27/2004
01/23/2004
01 /23/2004
0111 W2004
12/31 12003
12/31/2003
Description
89 Final Combo
89 Final Combo
84 Rough Combo
84 Rough Combo
84 Rough Combo
14 FramelSteellBoltinghVelding
17 Interior Lath/Drywall
24 Rough/Topout
39 Final Electrical
17 Interior Lath/Drywall
39 Final Electrical
14 Frame/Steel/BoltinghVelding
34 Rough Electric
18 Exterior LatMDrywall
14 Frame/Steel/Bolting/Welding
17 Interior LatWDrywall
Act lnsp Comments
CO PS OKTOSTOCKONLY
co PS
PA PS T-BAR
CO PS SPLAY WIRE NOT 45 DEGREE ANGLE
CO PS T-BAR
wc PS
AP PS COMPLETE wc PS
CO PS EMR
PA PS 2 FLYING CEILING
NR PS
AP TP S1
AP TP
AP PS
AP PS @
AP PS
'P. GYP CElL
'IRE DAMPER
City of Carlsbad Bldg Inspection Request
For: 02/11/2004
Permit# CB032562 Inspector Assignment: PS
Title: 2 GALLERIE-10,014 SF SHELL TO
Description: RETAl L
Type: TI Sub Type: COMM
Job Address:
Location:
191 5 CALLE BARCELONA
Suite: 135 Lot 0
APPLICANT JAKE WEBSTER
Owner:
Remarks:
Phone: 5209776541
Inspector!
Total Time:
CD Description
19 Final Structural
Requested By: WES
Entered By: CHRISTINE & Comment
29 Final Plumbing
39 Final Electrical r 49 Final Mechanical
Associated PCRs/CVs
PCR04010 ISSUED 2 GALLERY REV DRYWALLCEILING;
Date
02/09/2004
02/06/2004
02/03/2004
01/28/2004
01/28/2004
01/28/2004
01 /28/2004
01/27/2004
0 1 /27/2004
01/23/2004
01 /23/2004
01/13/2004
12/31/2003
12/31/2003
12/30/2003
12/23/2003
Inspection History
Description
84 RoughCombo
84 RoughCombo
84 RoughCombo
14 Frame/Steel/BoltingMlelding
17 Interior Lath/Drywall
24 RougWopout
39 Final Electrical
17 Interior LathlDrywall
39 Final Electrical
14 Frame/Steel/BoltingMlelding
34 Rough Electric
18 Exterior LathIDrywall
14 Frame/Steel/BoltingMlelding
17 Interior LatWDrywall
17 Interior Lath/Drywall
16 Insulation
Act lnsp Comments
CO PS SPLAY WIRE NOT 45 DEGREE ANGLE
CO PS T-BAR
wc PS
AP PS COMPLETE wc PS
CO PS EMR
PA PS 2 FLYING CEILING
NR PS
AP TP SUPP.GYPCElL
AP TP
AP PS
AP PS @ FIREDAMPER
AP PS
AP PS BACKOFHOUSE
AP PS
PA PS T-BAR
1 I
CITY OF CARLSBAD NOTICE (760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
FORMATION, CONTACT
PHONE
@ BUILDING ~NSPECTOR CODE ENFORCEMENT OFFICER
City of Carlsbad Bldg
For: 01 /28/2004
Permit# CB032562
Title: Z GALLERIE-l0,014 SF SHELL TO
Description: RETAIL
Type: TI Sub Type: COMM
Job Address:
Location:
191 5 CALLE BARCELONA
Suite: 135 Lot 0
APPLICANT JAKE WEBSTER
Owner:
Remarks: FRAME 0 HARD LIDS & PERM ELEC
Total Time:
Inspection Request
Inspector Assignment: PS
Phone: 5209776541
Inspector: ?I
Requested By: WES
Entered By: CHRISTINE
CD Description Act Comment
14 - Frame/SteeUBolting/Welding ~ 4
24 Roughmopout L
Y T7
Associated PCRsKVs
Inspection History
Date Description Act lnsp Comments
PCR04010 ISSUED Z GALLERY REV DRYWALL CEILING,
01 127/2004
01 /27/2004
01123/2004
01123/2004
01/13/2004
12/31/2003
12/31/2003
12/3012003
12/23/2003
12/23/2003
12/1 912003
12/1 912003
12/19/2003
12/1 712003
12/17/2003
12/1 712003
la1 512003
12/1 512003
17 Interior LathlDrywall
39 Final Electrical
14 Frame/Steel/Boltin@Velding
34 Rough Electric
18 Exterior LatWDrywall
14 FramelSteellBoltin@Velding
17 Interior LathIDrywall
17 Interior LathIDrywall
16 Insulation
17 Interior LathIDrywall
17 Interior LathlDrywall
34 Rough Electric
44 RougWDuctsIDampers
14 Frame/SteellBoltin@Velding
34 Rough Electric
44 RougWDuctsIDampers
14 Frame/Steel/BoltingiWelding
24 RoughlTopout
PA PS
NR PS
AP TP
AP TP
AP PS
AP PS
AP PS
AP PS
AP PS co PS
AP PS
AP PS
AP PS
co PS
co PS
co PS
AP PS
AP PS
2 FLYING CEILING
SUPP. GYP CElL
@ FIRE DAMPER
BACK OF HOUSE
WALLS SALES AREA
CONDUIT SALES AREA
CEILINGS (SEE NOTICE AlTACHED)
BACK OF HOUSE
.IAN-2 7-2004 02 : 14PM FQOM-TR I UMPH BU I LEERS
I
T-793 P.001/001 F-256 520 622 5688
Triumph Buiklers, Inc,
3450 E.Broadmont Dr. Suite 110 Tucson, Amorrr 85713
Ph. 520622-2884
Fax52W22-0888 www. triumphbuiklers.com
January 27,2004
City of Carlsbad
Building Department
1635 Faraday Ave.
Carlsbad, CA 92008
Dear Sir or Madam:
We hereby request to have our meter set for permanent power and for testing purpes, and
final punchout. This request is lbr building permit number C8832562 at Z-Gdlerie, 1915 Calk
Barcelona, Suite 135, in Carlsbad, Caliibmia,
We understand there is to be no store stocking until Certificate of Occupancy is obtained.
Sincerely, A
/ .. Wes Harper
Project Manager
Cc: File
01/27/28134 12: 31 3186381230 ZGPlUERIE LOSS PREV PAGE 81
Z GALIERIE. Facilities and New Construction
January 27,2004
C@ of Carlsbad, Building Dept.
To Whom It May Concern:
Z Gdlerie, Inc. quossts that the power be turned on at wr retall lbcatian on 1916 Calk Barcelona, in Carisbad, CA. This requast is submitted pursuant to buitdq permit number C8032562.
We undeMand that the stwe is not to be stocked or othQtwi6e occupied una all finah have beon received, including the final Certificate of Occuprvrcy.
Please call with any questions or concerns.
Director, Fadllttes & New Construction
2 Gallerie, Inc.
1855 w. 139" st.
Gardena, CA 90249
31 0-7 10.0 1 29 Jwa~Zgallerie.ccm
City of Carlsbad Bldg Inspection Request
For: 1 1/13/2003
Permit# CB032562 Inspector Assignment: V?
Title: 2 GALLERIE-10,014 SF SHELL TO
Description: RETAIL
Type: TI Sub Type: COMM
Job Address: 1915 CALLE BARCELONA
Suite: 135 Lot 0
Location:
APPLICANT JAKE WEBSTER
Owner:
Remarks: AM PLEASE
Total Time:
CD DescriDtion Ac Commen
Phone: 5209776541
lnspecto f631-
Requested By: WES HARPER
Entered By: CHRISTINE
Associated PCRs/CVs
Date Description Act lnsp Comments
- N CITY OF CARLSBAD
BUILDING DEPARTMENT
OTICE (760) 602-2700
1635 FARADAY AVENUE
TIME
PERMIT NO.
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? YES
PHONE
@ CODE ENFORCEMENT OFFICER
.
City of Carlsbad Bldg Inspection Request
For: 1 1/17/2003
Permit# CB032562 Inspector Assignment: PS
Title: 2 GALLERIE-10,014 SF SHELL TO
Description: RETAl L
Type: TI Sub Type: COMM
Job Address: 1915 CALLE BARCELONA
Suite: 135 Lot 0
Location:
APPLICANT JAKE WEBSTER
Owner:
Remarks:
Phone: 5209776541
Inspector: v
Total Time: Requested By: WES
CD Description
Entered By: KAREN 2 Comment 17 Interior LatWDrywall
31 UndergroundKonduit-Wiring &?-
22 Sewerwater Service &z
Associated PCRsKVs
lnsuection History
Date Description Act lnsp Comments
11/13/2003 17 Interior Lath/Drywall PA PS SOUTH WALL & EAST WALL TO BOTTOM OF TJI
, N * *-
CITY OF CARLSBAD
BUILDING DEPARTMENT
OTlCE (760) 602-2700
1635 FARADAY AVENUE
TIME
- PERMIT NO. "3 zs
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? YES
PHONE
CODE ENFORCEMENT OFFICER @
City of Carlsbad Bldg
For: 1 1/24/2003
Permit# CB032562
Title: 2 GALLERIE-10,014 SF SHELL TO
Description: RETAIL
Type: TI Sub Type: COMM
Job Address:
Location:
191 5 CALLE BARCELONA
Suite: 135 Lot 0
APPLICANT JAKE WEBSTER
Owner:
Remarks:
Total Time:
Inspection Request
Inspector Assignment: PS
Phone: 5209776541
Inspector: c;5
Requested By: LES
Entered By: CHRISTINE
CD Description Act Comment a T- 11 Ftg/Foundation/Piers
14 Frame/SteeVBolting/Welding
34 Rough Electric
Associated PCRs/CVs
InsDection History
Date Description Act lnsp Comments
1 1/19/2003 17 Interior Lath/Drywall PA PS ABOVE TJI S PREM WALLS
AP PS 11/19/2003 21 UndergrouncUUnder Floor
11/17/2003 17 Interior LatWDtywall PA PS
co PS 11/17/2003 22 SewerANater Service
11/17/2003 31 Underground/Conduit-Wiring AP PS
1 111 3/2003 17 Interior LathIDrywall PA PS SOUTH WALL & EAST WALL TO BOTTOM OF TJI
NOTICE (760) 602-2700
', Aa
CITY OF CARLSBAD BUILDING DEPARTMENT 1635 FARADAY AVENUE
ri FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? YES
PHONE ~FC~MATION, CONTACT
;V&f [/<+
@ BUILDING INS~EC~OR CODE ENFORCEMENT OFFICER
City of Carlsbad Bldg Inspection Request
For: 12/17/2003
Permit# CB032562 Inspector Assignment: PS
Title: Z GALLERIE-10,014 SF SHELL TO
Description: RETAIL
Type: TI Sub Type: COMM
Job Address: 1915 CALLE BARCELONA
Suite: 135 Lot 0
Location:
APPLICANT JAKE WEBSTER
Owner:
Remarks:
Total Time:
Phone: 5209776541
Inspector: '3s
Requested By: WES
Entered By: ROBIN
CD Description
14 Frame/SteeVBolting/Welding
/
I f 34 Rough Electric
44 Rough/Ducts/Dampers
___- Associated PCRs/CVs
Inspection Historv
Date Description
12/1 512003
12/1 512003
12/1 512003
12/1 112003
12/1 112003
12/11/2003
12/1 Ol2003
12/09/2003
12/04/2003
12/02/2003
12/02/2003
11/26/2003
11/25/2003
11/24/2003
11/24/2003
11/24/2003
1 111 912003
1 111 912003
1 111 7/2003
14
24
34
14
24
34
84
14
17
11
17
17
11
11
14
34
17
21
17
Frame/Steel/BoltinyWelding
RoughITopout
Rough Electric
Frame/Steel/BoltingAWelding
Rough Electric
Rough Combo
Frame/Steel/BoltingNVelding
Interior LatWDrywall
FtgIFoundationlPiers
Interior LatWDrywall
Interior LathlDrywall
FtgIFoundationlPiers
FtglFoundatiodPiers
FramelSteeVBoltingNVelding
Rough Electric
Interior Lath/Drywall
UndergroundlUnder Floor
Interior LatWDrywall
Roughl-ropout
Act lnsp
AP PS
AP PS
AP PS
co PS
co PS
co PS
co PS
PA PS
PA PS
AP PS
PA PS
AP PS
AP PS co PS
co PS
PA PS
PA PS
AP PS
PA PS
Comments
BACK OF HOUSE
NO FIRE APPROVAL
FRONT AREA
NOTED ON PLANS
@ WALK OFF AREA
NORTH WALL
PATCH BACK
COLUMN & 0-WALLS
ABOVE TJI S PREM WALLS
Carlsbad 03-2562
10/31/03 - EsGil Corporation
In Turtmrship with @wernmcnt for BuiGfing Sufety
DATE: 10/31/03
J U RI S D I CTl ON : Carlsbad
PLAN CHECK NO.: 03-2562 SET III
PROJECT ADDRESS: 1915 Calle Barcelona, Suite 135
PROJECT NAME: 2- Gallerie TI
0
0
0
0
0
El
n PLANREVIEWER
0 FILE
The plans transmitted herewith have been corrected where necessary and subsfantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant‘s copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: )
Mail Telephone Fax In Person
REMARKS: City to field verify that the existing &k$ parking complies with the
current standards. I/
By: Chuck Mendenhall Enclosures:
Esgil Corporation
GA MB 0 EJ 0 PC 10/27/03 tmsrn%.dot
EsGil Corporation
In Tartmrsfiip with Gouernment for Buiuing Safety
DATE: 10/17/03
JURISDICTION : Carlsbad
PLAN CHECK NO.: 03-2562
0 PLAN REVIEWER a FILE
SET: I1
PROJECT ADDRESS: 1915 Calle Barcelona, Suite 135
PROJECT NAME: Z Gallerie TI
The plans transmitted herewith have been corrected where necessary and substantially comply
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
with the jurisdiction’s building codes.
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
‘
Corporation until corrected plans are submitted for recheck.
contact person.
The applicant’s copy of the check list has been sent to:
Jake Webester
1327 Post Ave., Suite ‘H’, Torrance, CA 90501
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Jake Webster Telephone #: (31 0) 328-6300 X 1 14
Date contacted: p I . (by: by) F~x #: (310) 328-8545
Mail C/ Telephone Fax/ In Person
REMARKS:
By: Chuck Mendenhall Enclosures:
Esgil Corporation
GA 0 MB 0 EJ 0 PC 1 0/13/03 tmsmtkdot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 (858) 560-1468 Fax (858) 560-1576
' ..
CITY OF CARLSBAD NOTICE 1760) 602-2700
BUILDING DEPARTMENT 1635 FARADAY AVENUE
TIME
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? E YES
mFm .E6 INFORPATION, CONTACT
,,
/ . Fn -- PHONE
xi/,/ /
@ - 'BUILDING I~~SPECTOR' CODE ENFORCEMENT OFFICER
Carlsbad 03-2562
10/17/03
The items listed below are from the previous correction list. These
remaining items have not been adequately addressed. The numbers of the
items are from the previous check list and may not necessarily be in
sequence.
Please make all corrections on the original tracings, as requested in the
correction list. Submit three sets of plans for commerciaVindustriaI projects
(two sets of plans for residential projects). For expeditious processing,
corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA
92008, (760) 602-2700. The City will route the plans to EsGil Corporation
and the Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculationsheports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123,
(858) 560-1 468. Deliver all remaining sets of plans and calculations/reports
directly to the City of Carlsbad Building Department for routing to their
Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until
review by EsGil Corporation is complete.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
NOTE:
e ACCESSIBLE PARKING
lone of the disabled access items listed below were addressed with
this resubmittal
6.
7.
Show on the plans the disabled accessible parking and the path of travel
from the parking to the tenant space.
Show on the site plan the required number of accessible parking spaces for
new facilities. Per Table 1 18-7 the minimum number of spaces is:
a)
b)
1 for each 25 spaces up to 100 total spaces.
1 additional space for each 50 spaces for between 101 and 200 total
spaces.
Carlsbad 03-2562
10/17/03
8.
9.
10.
11.
12.
13.
Show that accessible parking spaces comply with Section 11298.4.1 as
follows:
a) Single spaces shall be 14' wide and outlined to provide a 9' parking
area and a 5' loading and unloading area on the passenqer side of
the vehicle.
When more than one space is provided, in lieu of providing a 14'
space for each space, two spaces can be provided within a 23' area
with a 5' loading zone between each 9'0" wide space.
Each space is to be a minimum of 18' in depth.
b)
c)
At least one in every 8 accessible parking spaces shall be served by an
access aisle 296" in width and designated as VAN ACCESSIBLE, per
Section 1 129B.4.2.
The words "NO PARKING" shall be painted on the ground within each 8'
loading and unloading access aisle (in white letters no less than 12" high
and located so that it is visible to traffic enforcement officials). Section
1 129B.4.2.
Ramps shall not encroach into any accessible parking space or the
adiacent access aisle. Section 1 129B.4.3.
0 COUNTERS AND TABLES
The tops of service counters shall be 28 to 34" from the floor. Show that
the cash wrap counter will have ) at least a 36 long area and no more than
28 to 34" high. Section 1 122B.4.
0 REST ROOM FIXTURES
Show in detail 21 A8 that water closet grab bars comply with the following,
per Section 1 1 15B.8:
a) They shall be securely attached 33" above the floor. The detail
shows 36 height.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet, note or detail
number, calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone
number of 858/560-1468, to perform the plan review for your project. If
rc
Carlsbad 03-2562
10/17/03
you have any questions regarding these plan review items, please contact
Chuck Mendenhall at Esgil Corporation. Thank you.
EsGil Corporation
In !Partnership with tjouernmnt for Building safety
DATE: 9/26/03
JURISDICTION: Carlsbad
PLAN CHECK NO.: 03-2562
Cl PLAN REVIEWER
0 FILE
SET: I
PROJECT ADDRESS: 1915 Calle Barcelona, Suite 135
PROJECT NAME: Z- Gallerie TI
CI
0
0
w
0
w
o
rn
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Jake Webester
1327 Post Ave., Suite ‘H’, Torrance, CA 90501
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Jake Webster Telephone #: (310) 328-6300 X 114
Date contacted: 9 129 /03 (by: tc ) F~x #: (310) 328-8545
Mail eelephone Faxv In Person
REMARKS:
By: Chuck Mendenhall Enclosures:
Esgil Corporation
GA 0 MB 0 EJ 0 PC 9/18/03 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 (858) 560-1468 + Fax (858) 560-1576
Carlsbad 03-2562
9/26/03
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 03-2562
OCCUPANCY: M
TYPE OF CONSTRUCTION: VN
ALLOWABLE FLOOR AREA: no change
SPRINKLERS?: yes
REMARKS:
DATE PLANS RECEIVED BY
J U RIS D I CTl ON :
DATE INITIAL PLAN REVIEW
COMPLETED: 9/26/03
JURISDICTION: Carlsbad
USE: retail store
ACTUAL AREA: 10,014 TI Only
STORIES: no change
HEIGHT: no change
OCCUPANT LOAD: 276
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 9/18/03
PLAN REVIEWER: Chuck Mendenhall
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet number, specification section, etc.
Be sure to enclose the marked UP list when vou submit the revised plans.
I*
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1 997UBC) fifowdot
Carlsbad 03-2562
9/26/03
1.
2.
3.
4.
5.
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
Smoke/ fire dampers shall be installed per Section 713.10 at all ducted or
unducted air openings at penetrations of:
a) Corridors or horizontal exit walls. Show on sheet Mi that the HVAC duct
and transfer grill ducts penetrating the corridor walls will be
equipped with smoke and fire dampers.
Show in detail 1/Al that the existing roof assembly above the fire rated corridor
is one hour construction.
Include with the plans the design and construction details for the entry awning as
shown in section l/AlO.
ELECTRICAL
Provide multiple switch lighting controls within site of the sales floor lighting per
Title 24, Part 6.
Detail required exterior lighting controls. “Exterior lighting controlled from a
lighting panel within the building shall be controlled by a directional photocell or
astronomical time switch that automatically turns off exterior lighting when
daylight is available.’’
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
? Carlsbad 03-2562
9/26/03
0 REMODELS, ADDITIONS AND REPAIRS
When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B.2. These
requirements apply as follows:
a)
b)
The area of specific alteration, repair or addition must comply as "new"
construction.
A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
0 ACCESSIBLE PARKING
6.
7.
Show on the plans the disabled accessible parking and the path of travel from the
parking to the tenant space.
Show on the site plan the required number of accessible parking spaces for new
facilities. Per Table 1 1 B-7 the minimum number of spaces is:
a) 1 for each 25 spaces up to 100 total spaces.
b) 1 additional space for each 50 spaces for between 101 and 200 total spaces.
Show that accessible parking spaces comply with Section 11296.4.1 as follows:
a) Single spaces shall be 14' wide and outlined to provide a 9' parking area and a 5' loading and unloading area on the passenaer side of the vehicle.
b) When more than one space is provided, in lieu of providing a 14' space for each space, two spaces can be provided within a 23' area with a 5' loading
zone between each 9'0'' wide space.
Each space is to be a minimum of 18' in depth.
8.
c)
At least one in every 8 accessible parking spaces shall be served by an access
aisle 296" in width and designated as VAN ACCESSIBLE, per Section 1 1296.4.2.
9.
10. The words "NO PARKING" shall be painted on the ground within each 8' loading
and unloading access aisle (in white letters no less than 12 high and located so
that it is visible to traffic enforcement officials). Section 1129B.4.2.
Ramps shall not encroach into any accessible parking space or the adjacent
access aisle. Section 1 129B.4.3.
11.
0 COUNTERS AND TABLES
Carlsbad 03-2562
9/26/03
12. The tops of service counters shall be 28” to 34” from the floor. Show that the cash
wrap counter will have ) at least a 36 long area and no more than 28” to 34” high.
Section 1 122B.4.
0 REST ROOM FIXTURES
13. Show in detail 2/ A8 that water closet grab bars comply with the following, per
Section 11 158.8:
a) They shall be securely attached 33” above the floor. The detail shows 36
height.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet, note or detail number,
calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Chuck Mendenhall
at Esgil Corporation. Thank you.
.
Bldg. Permit Fee by Ordinance
Cksbad 03-2562
9/26/03
V
PALUATION AND PLAN CHECK FEE
JURI SD lCTl ON: Carlsbad PLAN CHECK NO.: 03-2562
PREPARED BY: Chuck Mendenhall DATE: 9/26/03
BUILDING ADDRESS: 1915 Calle Barcelona, Suite 135
3UILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN
Jurisdiction Code (cb By Ordinance I
Plan Check Fee by Ordinance 1 V 1
Type of Review:
Ozrtitive ~ee Repeats
Complete Review Structural Only
Other
I3 Hourly -1 Hour *
Esgll Plan Revlew Fee
I $1,165.641
I $757.671
Comments:
Sheet 1 of 1
macvalue.doc
PLANNINC/ENCINEERING APPROVALS
PERMIT NUMBER CBn3 - gFb2 DATE ?-/%-O3
RESIDENTIAL / TENANT IMPROVEM~T
RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL
( < $1 0,000.00)
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
Docmisforms/Pianning Engineering Approvals
$2 d
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CS&Wa Address /(-?Is Ed muc -elon&
Planner Chris Sexton
APN: ~255 />/a 15
Type of Project & Use: -f-t Net Project Density: DU/AC
Zoning: P-pd General Pla#b! R
CFD (inlout) #-Date of participation:
Phone 1760) 602-4624 - -
tf Facilities Management Zone:
Remaining net dev acres:
(For non-residential development: Type of land used created by this
permit: 1 Circle One
Leaend: Item Complete 0 Item Incomplete - Needs your action
Environmental Review Required:
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES - NO TYPE
APPROVAURESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
YES - NO LTYPE
Coastal Zone AssessmenVCompliance
Project site located in Coastal Zone? YES- l/ NO-
CA Coastal Commission Authority? YES- NO-
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego CA 92108402; (61 9) 767-2370
Determine status (Coastal Permit Required or Exempt): GXem ot'
Coastal Permit Determination Form already completed?
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
9
YES-' NO-
Follow-Up Actions:
1)
2)
Stamp Building Plans as 'Exempt" or 'Coastal Permit Required" (at mininium Floor Plans).
Complete Coastal Permit Determination Log as needed.
(Effective date of lnclusionary Housing Ordinance - May 21 , 1993.)
lnclusionary Housing Fee required: YES - NO - /
Data Entry Completed? YES - NO -
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YM,
Enter Fee, UPDATE!)
Site Plan:
H:\ADMIMCOUNTER\BldgPlnchkRevChklst Rev glD1
/
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, prope-ty. lines. easements, existing and proposed StrUCtureS, streets, existing street improvements, right-of-wav
width, dimensional setbacks and existing topographical lines (including all side and rear y&
slopes).
2. Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Guidelines
1. Applicability: YES NO
2. Project complies YES NO
Zoning:
1. Setbacks:
Front: Required .+k-, Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Top of slope: Required Shown
2. Accessory structure setbacks:
Front: Required
Interior Side: Required
Street Side: Required
Rear: Required
Structure separation: Required
3. Lot Coverage: Required @L Shown
4. Height: Required f34t-4 Shown
5. Parking: Spaces Required & Shown
Residential Guest Spaces
Additional Comments
(breakdown by uses for commercial and industrial projects required)
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER m- D*T~?/~YA~
H:\ADMIMCOUNTER\BldgPnchkRevChklst Rev MI1
-,Carlsbad Fire Department 032562
1635 Faraday Ave. Fire Prevention
aICarlsbad, CA 92008 (760) 602-4660
Plan Review Requirements Category; Building Plan
Date of Report: 10/01/2003 Reviewed by:
Name: Express Permits
Address: 1327 Post Av #H
City, State: Torrance CA 90501
Job #: 032562 Plan Checker:
Job Name: Z Gallerie Bldg #: CB032562
Job Address: 191 5 Calle Barcelona Ste. or Bldg. No.
0 Approved The item you have submitted for review has been approved. The approval is
based on plans, information and I or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. .At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2nd 3 rd Other Agency ID
FD Job # 032562 FD File #
Carlsbad Fire Department 032562
*.
' 1635 Faraday Ave. . Carlsbad, CA 92008
Plan Review
Date of Report: 10/01/2003
Name: Express Permits
Fire Prevention
(760) 602-4660
Reviewed by:
Address: 1327 Post Av #H
City, State: Torrance CA 90501
032562 Plan Checker:
Job Name: 2 Gallerie
Job Address: 1915 Calle Barcelona Ste. or Bldg. No.
Fire does not require the proposed Fire Alarm system be installed. It is strongly suggested that the
proposed Fire Alarm system be omitted. Local smoke detection is acceptable. Central station
monitoring is not required by either UFC or UBC. If applicant strongly desires to have installed said
alarm system, plans must be submitted seperatefy.
Requirements *, Category: Building Plan
0
Requirement: Pending 05. I a Fire Extinguishers Required
Provide one 2AlOBC fire extinguisher for each 6000 square feet or portion thereof with a travel
distance to the nearest extinguisher not to exceed 75 feet of travel. Provide notes on the plans that
the extinguisher will be provided.
Page 1 10101 I03
,
c
200m coo
Y 8n
I sir
-1
City of Carlsbad 1 It
1635 Faraday Av Carlsbad, CA 92008
01 -1 5-2004 Plan Check Revision Permit No: PCR04010
Building Inspection Request Line (760) 602-2725
Job Address: Permit Type: PCR Status: ISSUED Parcel No: Lot #: 0 Applied: 01/15/2004
Valuation: $0.00 Construction Type: NEW Entered By: SB
Reference #: Plan Approved: 01/15/2004
Issued: 01/15/2004 Project Title: Z GALLERY REV DRYWALL CEllLlNG Inspect Area:
191 5 CALLE BARCELONA CBAD St: 135
Applicant:
TRIUMPH BUILDERS
3450 E BROADMOUNT 85713 520-977-6541
Owner:
Plan Check Revision Fee
Additional Fees
$60.00 $0.00
Total Fees: $60.00 Total Payments To Date: $0.00 Balance Due: $60.00
FINAL APPROVAL I
Inspector: Date: Clearance:
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "feeslexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified feeslexactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
feeslexact ions of which YOU ha ve Drevioustv been a iven a NOT ICF similar to this. or as to wh ich the statute o f limitations has ore viouslv otherwise exoired.
, (. PERMIT APPLICATION
FOR OFFICE USE ONLY
PLAN CHECK NO.
CITY OF CARLSBAD BUILDING DEPARTMENT I
1635 Faraday Ave., Carlsbad, CA 92008
EST. VAL.
Plan Ck. Deposit
Validated By -55
Date 1 1 II, lrjcr
%c& RZ
Business Name (at this address)
Legal Description Lot No. Subdivision NamelNumber Unit No. Phase No. Total # of units
ssessor's Parcel # Existing Use Proposed Use
Description of Work SQ. FT. #of Stories t of Bedrooms # of Bathrooms
Name Address city Statelzip Telephone # Fax #
Name Address City Statelzip Telephone t
State License #
Designer Name Address city Statelzip Telephone
City Business License #
State License #
8. WO~ltSf.'C0#PENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 of the work for which this permit is issued.
0 issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS I81001 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful. and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ~8100.000~. In addition to the cost of compensatlon, damages as provided for in Section 3706 of the Labor code, interest and attorney's fens.
SIGNATURE DATE
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
0
1.
2.
3.
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
I have and will maintain workers' compensation. as required by Section 3700 of the Labor Code, for the Performance of the work for which this permit is
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0
I (have / have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name l address I phone number / contractors license number):
Business and Professions Code for this reason:
4.
number / contractors license number):
5.
I plan to provide-portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address l phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address I phone number / type of work):
PROPERTY OWNER SIGNATURE DATE
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
0 YES 0 NO
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THiS PERMIT.
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is permit or if the building or work authorized by such permit IS suspended or abandoned
at any time after the work is Uniform Building Code).
APPLICANT'S SIGNATURE DATE /5:0/
Applicant PINK: Finance
. I., EsGil Corporation
In Partmrsfiip witfi ~overnmcnt for BBuiliiing Safety
DATE: 1/15/04 0 APPLICANT
JURI SD I CTlO N: Carlsbad 0 PLAN REVIEWER
PLAN CHECK NO.: 03-2562 (PCRO4-010) SET:REV 1, I
0 JURIS.
0 FILE
PROJECT ADDRESS: 1915 Calle Barcelona, Suite 135
PROJECT NAME: 2- Gallerie TI
The revised plans transmitted herewith have been corrected where necessary and substantially
0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when
comply with the jurisdiction’s building codes.
minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at Esgil
0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
Corporation until corrected plans are submitted for recheck.
contact person.
0 The applicant’s copy of the check list has been sent to:
0 Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Triumph Builders Telephone #: In Person
Date contacted: 1/15/04 (by: CM) Fax #:
Mail Telephone Fax In Person
REMARKS:
By: Chuck Mendenhall Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC walk in trnsmtl.dot
I I I.
Plan Check Fee by Ordinance
VALUATION AND PLAN CHECK FEE
v
JURISDICTION:. Carlsbad PLAN CHECK NO.: 03-2562 (PCRO4-010)
PREPARED BY: Chuck Mendenhall DATE: 1/15/04
BUILDING ADDRESS: 1915 Calle Barcelona, Suite 135
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN
Valuation Reg. VALUE ($)
Multiplier Mod.
1 I I I I I I I
Misc Rev I NA I Hrlv I I I
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code (cb IBy Ordinance
Bldg. Permit Fee by Ordinance
I
I V
Type of Review: 0 Complete Review
u Repetitive Fee Repeats
I $60.00~
Structural Only
0 Other
Hourlv 10.5) Hour*
Esgll Plan Review Fee I $48.001
* Based on hourly rate
Comments:
Sheet 1 of 1
macvalue.dcc