Loading...
HomeMy WebLinkAbout1915 CALLE BARCELONA; 130; CB041289; Permit1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 \ &-'6-2004 Commercial/lndustriaI Permit Permit No: CB041289 Job Address: Permit Type: TI Sub Type: COMM Parcel No: Lot#: 0 Valuation: $191,460.00 Construction Type: NEW Occupancy Group: Reference #: Project Title: 191 5 CALLE BARCELONA CBAD St: 130 SUR LA TABLE 6382 SF TI SHELL TO RETAIL Applicant: DAVID MURPHY SUITE 21 1 2101 9TH AVE 98121 206-341-9875 Owner: Status: ISSUED Applied: 0411 612004 Plan Approved: 05/26/2004 Issued: 05/26/2004 Entered By: SB Inspect Area: Plan Check#: Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee $829.92 $0.00 $539.45 $0 .oo $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $40.21 $0.00 $0.00 Meter Size Add'l Recl. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0 .oo $0.00 $3,484.57 $0.00 $0.00 $0.00 $0.00 $0.00 $90.00 $60.00 $43.50 $0.00 $0.00 $0.00 $0.00 $5,087.65 Total Fees: $5,087.65 Total Payments To Date: $529.44 Balance Due: $4,558.21 I I . PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. 29' EST. VAL. / 57,460 Plan Ck. Deposit 529.4 Validated By , 5s Date '(/]Ah L / 'f 1- , 7- -_ Proposed use --= -31- Assessor's Parcel # Existmg Use No+ bCCUPikd It- DescnptionofWork TWWT It.Weh)Wac\r SQ FT #of Stones #of Bedrooms # of Bathrooms 6352 I 0 2 "5VC LPm6"pFt&\~m GL~%NG ButLDlW PAYID Mu@?w Zlo\ 9" A=.5ai+e ZU sa wpc 4AI Zt ?D6 - 34 1 - 9875 Name Address statelzip Telephone # Telephone # for which this permit is issued r the performance of the work for which this permit is issued. My Insurance Company ExpirationDate /% af 0 y IS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [OlOO] OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued. I shall not employ any person in any manner so as to NING: Failure to se rs(SlOO,OOO), in add rkers' compensation coverage is unlawful, and shall Subject an employer to criminal penalties and civi f compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorn 0 I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such wok himself or through his own employees, provided that such improvements are not intended or offered for Sale If, however, the building or improvement is sold wthin one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) 0 I, as Owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an Owner of property who builds or improves thereon, and contracts for such projects wth contractor(s) licensed pursuant to the Contractor's License Law) 0 1 2 3 I am exempt under Section I personally plan to provide the major labor and matenals for construction of the proposed property improvement 0 YES 0 NO I (havehave not) signed an application for a building permit for the proposed work I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number) Business and Professions Code for this reason 4. 5. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone number I Iontractors license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type of work): ~ ~ ~___ ~___ ___ ~ ~ PROPERTY OWNER SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance '\ \ 1 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 COWLETETWSSECrX)NFORS/~BUKDtNGFERMWSONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES @ NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES E NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCllON LE"GAG€NCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDERS NAME LENDERS ADDRESS e. ApwcANt~TloN I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is EXPIRATION: Every permit by such permit is not comme the work is commenced for a pe 0 YES NO Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after ection 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE I WHITE: File YELLOW: Applicant PINK: Finance \ Clty ef Carlsbad Final Building lnsuection 7 Dept: Building Engineering Planning CMWD St Litcw Plan Check #: Permit #: CB041289 Project Name: SUR LA TABLE 6382 SF TI SHELL TO RETAIL 191 5 CALLE BARCELONA #130 Address: Contact Person: N/A Phone: 951 3239651 Sewer Dist: Water Dist: Lot: Date: Permit Type: Sub Type: 0 07/26/2004 TI COMM .......................................................................................................................................................... 4 y Approved: %p proved: , Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: ........................................................................................................................................................... Comments: City of Carlsbad Bldg Inspection Request For: 08/12/2004 Permit# CB041289 Inspector Assignment: PS Title: SUR LA TABLE 6382 SF TI SHELL Description: TO RETAIL Type: TI Sub Type: COMM Job Address: 191 5 CALLE BARCELONA Suite: 130 Location: APPLICANT DAVID MURPHY Owner: Remarks: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Lot 0 Phone: 9513239651 Inspector: = Requested By: GARY Entered By: CHRISTINE I- I Associated PCRs/CVs Inspection HiGory Date Description 08/10/2004 89 07/29/2004 19 07/29/2004 29 07/29/2004 39 07/29/2004 49 07/26/2004 89 07/21/2004 23 07/20/2004 23 0711 312004 34 07/01/2004 17 06/30/2004 14 06/30/2004 44 06/29/2004 14 06/29/2004 24 06/29/2004 34 06/28/2004 17 Final Combo Final Structural Final Plumbing Final Electrical Final Mechanical Final Combo Gamest/ Repairs Gamest/ Repairs Rough Electric Interior LathIDrywall FramelSteellBoltingNVelding Roug WDuctdDampers FramelSteellBoltingNVelding RougWopout Rough Electric Interior Lath/Drywall Act lnsp co PS co PS AP PS AP PS AP PS eo PS AP PS PA PS AP PS AP PS AP PS AP PS co PS co PS co PS AP PS Comments RELEASE GAS 24HR TEST STARTED 24HR TEST RELEASE 1915 C.B. STE 130A HARD LID EsGil - Corporation In Partnership witih pmmnent for(2luiliiity Safety DATE: 5/21/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1289 0 APPLICANT 0 PLAN REVIEWER Q FILE amQ SET: I1 PROJECT ADDRESS: 1915 Calle Barcelona Suite 130 PROJECT NAME: Sur La Table - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified it the remarks below are resolved and checked by building department staff. and should be corrected and resubmitted for a complete recheck. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list 0 The check list transmitted herewith is for your information. The plans are .being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant 0 The applicant's copy of the check list has been sent to: contact person. w Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: REMARKS: Applicant to provide a completed special inspection form for field welding and add notes in red to City Held sets. Mail Telephone Fax In Person By: Doug Moody Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 511 3/04 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for BuiGiiing Safety DATE: 4/29/04 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1289 0 PLAN REVIEWER 0 FILE SET: I PROJECT ADDRESS: 1915 Calle Barcelona Suite 130 PROJECT NAME: Sur La Table -TI 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list . and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: David Murphy 2101 9* Ave Suite 21 1, Seattle, WA 98121 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: David Murphy d) Telephone #: 206-341-9875 ~203 Date contacted: Y/~?/ov (by: ) Fax #: 206-341 -91 77 Mail delephone1 Fad In Person 0 REMARKS: By: Doug Moody Enclosures: Esgil Corporation 0 GA MB 0 EJ PC 4/19/04 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ~~~~ City of Carlsbad 04-1289 4/29/04 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 04-1289 OCCUPANCY: M USE: Retail TYPE OF CONSTRUCTION: VN ACTUAL AREA: 6382sf ALLOWABLE FLOOR AREA: STORIES: 1 JURISDICTION: City of Carlsbad SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 4/16/04 HEIGHT: OCCUPANT LOAD: 179 DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/19/04 DATE INITIAL PLAN REVIEW COMPLETED: 4/ 29/ 04 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, Le., plan sheet number, specification section. etc. Be sure to enclose the marked UP list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 04-1289 4/29/04 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciallindustrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 1. 2. 3. 4. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support and lateral bracing of the stockroom shelving. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Please provide plans signed by the California State licensed engineer for the structural support of the HVAC clearly showing the findings in the calculations. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. 0 REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM FIELD WELDING REQUIRED? YES REMARKS 5. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. City of Carlsbad 04-1289 4/29/04 6. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 7. Show the ampere interrupting capacity (AIC) ratings of the sub-service equipment. NEC 110-9. 8. Provide complete kitchen hood plans, details, and calculations to show compliance with UMC, Chapter 5, Part II a) b) c) Provide the UL listing card showing the exhaust sizing requirements used for the hoods. Provide roof framing around new openings in the roof for the exhaust and make-up air ducts for kitchen hoods. Clearly show the material used to construct the exhaust duct to be 16 gauge and not 18 gauge. UMC, Sections 508.1.1 & 509.2 9. Please provide the ICBO listing and installation information for the duct wrap system. IO. Please review and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 1 I. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. 12. Please clarify the waste line diagram it appears to show a floor drain at the mop sink not shown on the floor plans? 13. Please correct the gas line diagram it show the same line to be both 2%'' and 2"? 14. Please provide a detail showing the installation of the gas line to the island cook top to comply with 121 1.4 of the UPC. 15. Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36 long and no more than 28" to 34" high. Section 1 1228.4. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, Le., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad 04-1289 * 4/29/04 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 9/29/04 04- 1289 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1289 PREPARED BY: Doug Moody DATE: 4/29/04 BUILDING ADDRESS: 1915 Calle Barcelona Suite 130 BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee v Type of Review: Complete Review 0 Structural Only 0 Other 0 Hourly -1 Hour * Esgll Plan Revlew Fee I $539.451 I $464.761 Comments: Sheet 1 of 1 rnacvalue.doc To: +I-7607299362 Page 3 of 3 2004-05-26 19:49:29 (GMT) 16233218006 From: Gary Stebbings 05/25/2004 17: 03 2063419177 MURPHYVAREY PAGE 03 2066243775 P.03 . ._-. - NRY-25-2004 15:38 COFFMFlN ENGINEERS-SER MURPHW4REy PME 03 P. 03 @5/25/2004 15:06 206341921T7 FAX No. 760 602 8558 w'f-24-2uU4 !XIION 08:U AH CITY OF CARSLtlAD . -. 1. R .n U nu 2. A. 33, C. 3. 'AI B C. PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST \9\5 ah- Plan Check No. f,fioLf (m Address , TA&, Planner Christer Westman Phone (760) 602-461 4 APN: Type of Project & Use: Net Project Density: DU/AC Zoning: General Plan: Facilities Management Zone: CFD (inlout) # Date of participation: Remaining net dev acres: Circle One (For non-residential development: Type of land used created by this permit: 1 Legend: @ Item Complete 0 Item Incomplete - Needs your action TYPE Environmental Review Required: YES NO - DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES - NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone AssessmentlCompliance Project site located in Coastal Zone? YES- NO- CA Coastal Commission Authority? - NO YES - If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt) : Coastal Permit Determination Form already completed? If NO, complete Coastai Permit Deteimination Form now. Coastal Permit Determination Log #: +. . - YES- NO Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determiqation Log as needed. H:\ADMIN\COUNTER\BldgPlnchkRevChklst olio OUU uno oclo oou @n lnclusionary Housing Fee required: YES - NO- (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) ? Data 'Entry Completed? YES - NO- ($IP/Ds, Actiyity Maintenance. enter CB#, toolbar, SFreens, Housing Fees, .Construct Housing Y /N, Enter Fee UPDATE'' ' t Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow; property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. 1. 2. 3. 4. 5. Zoning: Setbacks: Front: Required Shown Interior Side: Reauired Shown Street Side: Required Shown Rear: Required Shown Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required Shown Height: Required Shown Par king : Spaces Required Shown Guest Spaces Required Shown Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE DATE 9\44? H:\ADMIN\COUNTER\BldgPlnc hkRevC hklst PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 0 qy/ L&' 9 DATE 4-40 RESIDENTIAL TENANT IMPROVEMENT \, .( RES ID ENTIAL ADDITION M IN 0 R (<$10,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE ENGINEER DATE DocsIMislormstPlannin 0 Engineerinp Approvals Carlsbad Fire Department 041289 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan Date of Report: 05/18/2004 Reviewed by: Name: Nadel Architects Address: 5465 Morehouse Drive Suite 165 City, State: San Diego CA 92121 Job#: 041289 Plan Checker: Job Name: Sur La Table Bldg #: C6041289 Job Address: 1915 Calle Barcelona Ste. or Bldg. No. 130 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. 0 Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 0 Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2nd 3rd Other Agency ID FD Job # 041289 FD File # Christer Westman City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-2700 Re: Plan Check Corrections for 1915 Calle Barcelona #130, Plan Check #04-1289 Christer: The following is in response to Building Department plan review comments received by us on 4/26/04: i. Signage is not part of this permit. Use raised panel service doors as used elsewhere within Forum. Sign contractor has submitted application for sign permit. We will use raised panel service doors. 2. City of Carlsbad Plumbing - Electrical - Mechanical Worksheet attached. Completed worksheet is attached. Thank you, I/ Karen Hovde 2101 Ninth Avenue Suite 211 Seattle, Washington 98121 T: 206. 341. 9875 F: 206. 341 . 9177 M Carlsbad Fire Department 041 289 1635 Faraday Ave. Fire Prevention Carlsbad, CA 92008 (760) 602-4660 t. Plan Review Requirements Cafegory; Building Plan Date of Report: 04/29/2004 Reviewed by: Name: Murphy Varey Address: 2102 9th Ave. Suite 21 1 City, State: Seattle WA 98121 Job#: 041289 Plan Checker: Job Name: Sur La Table Bldg #: CB041289 Job Address: 191 5 Calle Barcelona Ste. or Bldg. No. 130 0 Approved Approved Subject to Incomplete The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2nd 3rd Other Agency ID FD Job # 041289 FD File # Requirements Category: Building Plan ~~ ~ Requirement: Pending 05.22 Exit Door Hardware Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exception, In group 8 occupancies, key locking hardware may be used on the Main Exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or adjacent to the door stating, "This door to remain unlocked during business hours." For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is occupied ." See item 32 for additional exit door hardware requirements. 1. ALL EXIT DOORS SHALL BE PROVIDED WITH SINGLE ACTION HARDWARE OR PANIC HARDWARE. 2. ALL DEADBOLT LOCKS SHALL BE DOUBLE CYLINDER. THUMBTURN LOCKSETS ARE ,NOT PERMITTED FOR USE. Page 1 04/29/04 n City of Carlsbad Building Department 1635 Faraday Avenue Carlsbad, CA 92008 (760) 602-2700 Re: Plan Check Corrections for 1915 Calle Barcelona #130, Plan Check#oq-i28g To Whom It May Concern: The following is in response to Fire Department plan review comments received by us on 5/4/04: i. All exit doors shall be provided with single action hardware or panic hardware. See attached specification sheets. 2. All deadbolt locks shall be double cylinder. Thumbturn locksets are not permitted for use. See attached specification sheets. Thank you, Karen Hovde 2101 Ninth Avenue Suite 211 Seattle, Washington 98121 T: 206. 341 . 9875 F: 206 . 341 . 9177 M , Carlsbad Fire Department 041289 1635 Faraday Ave. Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Requirements Category: Building Plan Date of Report: O4/29/*oo4 Reviewed by: Murphy Varey 2102 9th Ave. Received .QarPhy varey ps Name: Address: Suite 21 1 My 4 2004 City, State: Seattle WA 98121 m I Job#: 041289 Plan Checker: Sur La Table Bldg #: CB041289 - Job Name: . ... Job Address: 191 5 Calle Barcelona Ste. or Bldg. No. 130 Approved The item you have submitted for- review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or Specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 0 Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. I-- 1- Review 2nd 3rd Other Agency ID FD Job # 041289 FD File # ReGuiremen fs Category: Building Plan Requirement: Pending 05.22 Exit Door Hardware Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exception: In group B occupancies, key locking hardware may be used on the Main Exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or adjacent to the door stating, "This door to remain unlocked during business hours." For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is occupied." See item 32 for additional exit door hardware requirements. 1. ALL EXIT DOORS SHALL BE PROVIDED WITH SINGLE ACTtON HARDWARE OR PANIC HARDWARE. 2. ALL DEADBOLT LOCKS SHALL BE DOUBLE CYLINDER. THUMBTURN LOCKSETS ARE NOT PERMITTECW USE. 5- - Page 1 0412 9/04 Murphy Varey, PS - 2004 SUR LATABLE - THE FORUM AT CARLSBAD 08/03 4. Remote signal capability for connection to remote indicating panel. B. Manufacturers: 1. Detex Corporation (DTX). DOOR BOLTS Door Bolts for Means of Egress Doors: All deadbolt locks shall be double cvlinder. Thumbturn A. I 2-10 locksets are not permitted for use. B. Bolt Throw: Comply with testing requirements for length of bolts required for labeled fire doors, and as follows: 1. 2. 3. 4. 5. Half-Round Surface Bolts: Minimum 7/8-inch (22-mm) throw. Interlocking Surface Bolts: Minimum 15/i6-inch (24-mm) throw. Fire-Rated Surface Bolts: Minimum 1-inch (25-mm) throw; listed and labeled for fire-rated doors. Dutch-Door Bolts: Minimum 3/4-inch (19-mm) throw. Mortise Flush Bolts: Minimum 3/4-inch (19-mm) throw. C. Dustproof Strikes: BHMA A156.16. D. Surface Bolts: BHMA Ai56.16, Grade i unless Grade 2 is indicated. 1. Flush Bolt Heads: Minimum of i/;?-inch- (13-mm-) diameter rods of brass, bronze, or stainless steel with minimum 12-inch- (305-mm-) long rod for doors up to 84 inches (2134 mm) in height. Provide longer rods as necessary for doors exceeding 84 inches (2134 mm). 2. Available Manufacturers: a. Burns Manufacturing Incorporated (BM). b. Don-lo Mfg., Inc. (DJO). c. Door Controls International (DCI). d. e. Hager Companies (HAG). f. g. h. Trimco (TBM). Glynn-Johnson; an Ingersoll-Rand Company (GJ). IVES Hardware; an Ingersoll-Rand Company (IVS). Stanley Commercial Hardware; Div. of The Stanley Works (STH). E. Manual Flush Bolts: BHMA Ai56.16, Grade 1 unless Grade 2 is indicated; designed for mortising into door edge. 1. Available Manufacturers: a. b. d. e. f. g. h. i. C. i. Adams Rite Manufacturing Co. (ARM). Burns Manufacturing Incorporated (BM). Don-Jo Mfg., Inc. (DJO). Door Controls International (DCI). Glynn-Johnson; an Ingersoll-Rand Company (GI). Hager Companies (HAG). Hiawatha, Inc. (HIA). IVES Hardware; an Ingersoll-Rand Company (IVS). Stanley Commercial Hardware; Div. of The Stanley Works (STH). Trimco (TBM). DOOR HARDWARE 08710 - io F. 2.11 A. B. I c- D. E. F. G. Automatic and Self-Latching Flush Bolts: designed for mortising into door edge. BHMA Ai56.3, Grade i unless Grade 2 is indicated; I. Available Manufacturers: a. Cal-Royal Products, Inc. (CRP). b. Door Controls International (DCI). c. d. Hager Companies (HAG). e. f. Trimco (TBM). Glynn-Johnson; an Ingersoll-Rand Company (GJ). IVES Hardware; an Ingersoll-Rand Company (IVS). EXIT DEVICES Exit Devices: BHMA A156.3, Grade 1 Accessibility Requirements: Where handles, pulls, latches, locks, and other operating devices are indicated to comply with accessibility requirements, comply with the U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility Guidelines for Buildings and Facilities (ADAAG)." ANSI Aii7.1.1 I. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist and that operate with a force of not more than 5 Ibf (22 N). Exit Devices for Means of Egress Doors: All exit doors shall be provided with single action hardware or panic hardware. Comply with NFPA 101. Exit devices shall not require more than 15 Ibf (67 N) to release the latch. Locks shall not require use of a key, tool, or special knowledge for operation. Panic Exit Devices: Listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for panic protection, based on testing according to UL 305. Fire Exit Devices: Devices complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire and panic protection, based on testing according to UL 305 and NFPA 252. Outside Trim: Pull with cylinder; material and finish to match locksets, unless otherwise indicated. I. Match design for locksets and latchsets, unless otherwise indicated. Available Manufacturers: 1. 2. 3. 4. 5. 6. 7. 8. 9- 10. 11. 12. 13. 14. Adam Rite Manufacturing Co. (ARM). Arrow USA; an ASSA ABLOY Group company (ARW). Cal-Royal Products, Inc. (CRP). Corbin Russwin Architectural Hardware; an ASSA ABLOY Group company (CR). Detex Corporation (DTX). Door Controls International (DCI). DORMA Architectural Hardware; Member of The DORMA Group North America (DAH). Dor-0-Matic; an Ingersoll-Rand Company (DOR). Locknetics; an Ingersoll-Rand Company (LSE). Monarch Exit Devices & Door Hardware; an Ingersoll-Rand Company (MON). Precision Hardware, Inc. (PH). Rutherford Controls Int'l. Corp. (RCI). SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT). Von Duprin; an Ingersoll-Rand Company (VD). Murphy Varey, PS - 2004 SUR LA TABLE - THE FORUM AT CARLSBAD 08/03 DOOR HARDWARE 08710 - 11 SUR LA TABLE The Forum at Carlsbad Carlsbad, California Calculations Existing Roof Framing Review For New Mechanical Equipment April, 2004 Prepared by: OFFMAN 1F NGINEERS 1601 Fifth Avenue, Suite 900 Westlake Center Office Tower Seattle, Washington 9 (206)623-0717 &q I t 7' st 3' 1 NGINEERS OFFMAN AF NGINEERS NGINEERS I I- SEE WAJL 3 NOTES I IOWOE THWMWATS WLOCKABLE COMR AND OW THIS Locanm.PRaVW)~ '7 PFIOGRAMMABLE TSTAT STYLE WECONOMIZER CAPASIUPT. PRovlDE Au WlRNG AND Fiu~Ys. IM5.02 i ...... .... SHEET NO 1 BY G:..,*HAN!A! RACK DE$IGN & ENGINEERING CO. ................... DATE .............................. 5-3-04 3786 LA CREBCENTA AVE., dUITE 204 GLENDALE, CA. 91208 JOB NO. ....... R.D.78765,. SUBJECT. ...... -. ........ .- -. . TEL:( 81 8)957-2980 FAX:( 81 8)957-8603 SEISMIC ANALYSIS OF STORAGE PlPP MOBILE SYSTEM FOR: SUR LA TABLE Received MA)’ 0 4 2004 19 15 CALLE BARCELONA, SPACE #A 30 CARLSBAD, CA. 92009 Murphy vareyPS PER CBC 2001 EDITION STORAGE S H E LVI N G CAPACITY: 100 # / LEVEL CALCS. 1 THRU 4 DRAWINGS: RD-8765 SH. 1 ....................................... SHEET NO 2 BY G. OHANIAN RACK DESIGN & ENGINEERING co. ........... ............ DATE ................................... 5-3-04 3786 LA C'REPC'ENTA AVE., @UITE 204 .. GLENDALE, CA. 91208 JOB NO. ....... RD. -8765... .......................... SUBJECT. TEL(818)957-2980 FAx:(818)957-8603 1 60" 60" I I FIXED SHELVING SIDE VIEW I, ,, AM 100 # / LEVEL 50 # / BEAM K 60"~.05 = .3iK a M= 1 60" 60" I I MOBILE SHELVING SIDE VIEW "K S R= = .02<.06 22 BY. ....... G.-...,!?!'!AN!*N... DATE : 5-3-04 ................................ SU B J ECT. ......................... SHEET NO ........... 3 ............ - GLENDALE, C'A. 91208 JOB NO. ....... R.D.-8765.. RACK DE$IGN & ENGINEERING CO. 3786 LA CREPCENTA AVE., gUITE 204 TEL:(818)957-2980 FAx:(818)957-8603 SEISMIC DESIGN V= I= 1 R=5.6 Na=.44 W=D.L.+ L.L. CEC 2001 SEC. 2222 2.5xCaxl R I OAD PFR- COI UMN p= - - 2 W=.05 +.2 E .25 D.L. COLUMN ANALYSIS 3 1/4' COMBINED STRESS RATIO A=.40 i = . oa Smin=.08 rmin=.54 Q=.75 KSI Fy=36 - K .02 "K -c-- .05 * KSI Fa= 13.6 K Pa =Fa XA = 5.4 Ma =Zln.Fb= 1 .iK 0 =e+ 5 = .32<1.33 Pa Ma I .a ........ .... .... SHEET NO 4 BY 5: oHAN!AN RACK DE$IGN & ENGINEERING CO. ........... ............ ................................. 5-3-04 DATE SUBJECT. .......................... 3786 LA C‘REPC‘ENTA AVE., dUITE 204 RD-8765 .- GLENDALE, C‘A. 91208 JOB NO ............................... TEL:( 8 18)957-2980 FAX:( 8 18)957-8603 MOMENT AT BEAM CONNFCTION *K m5+*4 - .45 CONN.= 2 - 2 K v, = ‘25 x3.14 x80~.4=1.5 RIVET 4 K ”K Ma = 1.5 x1.5”x1.33=3.0 CONN BAsLaAE STATIONARY SHELVING K ANCHOR SHEAR = = .03K 2 USE (2)-I /4”@ ANCHOR PER EASE PLATE, 2” EMB. 3 3/4” 1-1 t=14GA. OVFRTU RN ING (STATIONARY UNITS) K “K MOT = .05 ~2~90”~.5~1.15 = 5.2 MR = .25 ~24”= 6 K “K NO UPLIFT MOBILE SHELVING MOBILE TRACK ANCHORD TO FLOOR W/ 1/4”2. ANCHORS Q 24” O.C. ANTI-TIP BOLTED TO MOBILE CARRIAGE W/ (2) 1/4”2 BOLTS SHELVING POST CONNECTED TO CARRIAGE W/ (2) 1/4”2 TEK SCREWS PER POST A- * 3 W \ I