HomeMy WebLinkAbout1915 CALLE BARCELONA; 130; CB041289; Permit1635 Faraday Av Carlsbad, CA 92008
Building Inspection Request Line (760) 602-2725
\
&-'6-2004 Commercial/lndustriaI Permit Permit No: CB041289
Job Address:
Permit Type: TI Sub Type: COMM Parcel No: Lot#: 0 Valuation: $191,460.00 Construction Type: NEW Occupancy Group: Reference #: Project Title:
191 5 CALLE BARCELONA CBAD St: 130
SUR LA TABLE 6382 SF TI SHELL TO RETAIL
Applicant: DAVID MURPHY
SUITE 21 1 2101 9TH AVE 98121 206-341-9875
Owner:
Status: ISSUED Applied: 0411 612004
Plan Approved: 05/26/2004 Issued: 05/26/2004
Entered By: SB
Inspect Area: Plan Check#:
Building Permit
Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount
Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee
Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee
Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee
$829.92 $0.00 $539.45
$0 .oo
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$40.21
$0.00
$0.00
Meter Size
Add'l Recl. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF
PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund)
PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee
Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES
$0.00
$0.00 $0 .oo
$0.00 $3,484.57
$0.00
$0.00 $0.00 $0.00
$0.00
$90.00 $60.00 $43.50
$0.00
$0.00
$0.00
$0.00
$5,087.65
Total Fees: $5,087.65 Total Payments To Date: $529.44 Balance Due: $4,558.21
I I
. PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO. 29'
EST. VAL. / 57,460
Plan Ck. Deposit 529.4
Validated By , 5s
Date '(/]Ah L /
'f
1- , 7-
-_ Proposed use --= -31- Assessor's Parcel # Existmg Use No+ bCCUPikd It-
DescnptionofWork TWWT It.Weh)Wac\r SQ FT #of Stones #of Bedrooms # of Bathrooms 6352 I 0 2 "5VC LPm6"pFt&\~m
GL~%NG ButLDlW
PAYID Mu@?w Zlo\ 9" A=.5ai+e ZU sa wpc 4AI Zt ?D6 - 34 1 - 9875
Name Address statelzip Telephone #
Telephone #
for which this permit is issued
r the performance of the work for which this permit is issued. My
Insurance Company ExpirationDate /% af 0 y
IS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [OlOO] OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued. I shall not employ any person in any manner so as to
NING: Failure to se
rs(SlOO,OOO), in add
rkers' compensation coverage is unlawful, and shall Subject an employer to criminal penalties and civi
f compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorn
0 I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec 7044,
Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such wok himself or
through his own employees, provided that such improvements are not intended or offered for Sale If, however, the building or improvement is sold wthin one year of
completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
0 I, as Owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's
License Law does not apply to an Owner of property who builds or improves thereon, and contracts for such projects wth contractor(s) licensed pursuant to the Contractor's
License Law)
0
1
2
3
I am exempt under Section
I personally plan to provide the major labor and matenals for construction of the proposed property improvement 0 YES 0 NO
I (havehave not) signed an application for a building permit for the proposed work
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number)
Business and Professions Code for this reason
4.
5.
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone number I
Iontractors license number):
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type of work):
~ ~ ~___ ~___ ___ ~ ~
PROPERTY OWNER SIGNATURE DATE
WHITE: File YELLOW: Applicant PINK: Finance
'\ \
1
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad CA 92008
Page 2 of 2
COWLETETWSSECrX)NFORS/~BUKDtNGFERMWSONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under
Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES @ NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES E NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
8. CONSTRUCllON LE"GAG€NCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code).
LENDERS NAME LENDERS ADDRESS
e. ApwcANt~TloN
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City
ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is
EXPIRATION: Every permit by such permit is not comme the work is commenced for a pe
0 YES NO
Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after ection 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE I
WHITE: File YELLOW: Applicant PINK: Finance
\
Clty ef Carlsbad
Final Building lnsuection
7 Dept: Building Engineering Planning CMWD St Litcw
Plan Check #:
Permit #: CB041289
Project Name: SUR LA TABLE 6382 SF TI SHELL
TO RETAIL
191 5 CALLE BARCELONA #130 Address:
Contact Person: N/A Phone: 951 3239651
Sewer Dist: Water Dist:
Lot:
Date:
Permit Type:
Sub Type:
0
07/26/2004
TI
COMM
..........................................................................................................................................................
4 y Approved: %p proved: ,
Inspected Date
By: Inspected: Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved: ...........................................................................................................................................................
Comments:
City of Carlsbad Bldg Inspection Request
For: 08/12/2004
Permit# CB041289 Inspector Assignment: PS
Title: SUR LA TABLE 6382 SF TI SHELL
Description: TO RETAIL
Type: TI Sub Type: COMM
Job Address: 191 5 CALLE BARCELONA
Suite: 130
Location:
APPLICANT DAVID MURPHY
Owner:
Remarks:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Lot 0
Phone: 9513239651
Inspector: =
Requested By: GARY
Entered By: CHRISTINE
I- I
Associated PCRs/CVs
Inspection HiGory
Date Description
08/10/2004 89
07/29/2004 19
07/29/2004 29
07/29/2004 39
07/29/2004 49
07/26/2004 89
07/21/2004 23
07/20/2004 23
0711 312004 34
07/01/2004 17
06/30/2004 14
06/30/2004 44
06/29/2004 14
06/29/2004 24
06/29/2004 34
06/28/2004 17
Final Combo
Final Structural
Final Plumbing
Final Electrical
Final Mechanical
Final Combo
Gamest/ Repairs
Gamest/ Repairs
Rough Electric
Interior LathIDrywall
FramelSteellBoltingNVelding
Roug WDuctdDampers
FramelSteellBoltingNVelding
RougWopout
Rough Electric
Interior Lath/Drywall
Act lnsp
co PS
co PS
AP PS
AP PS
AP PS
eo PS
AP PS
PA PS
AP PS
AP PS
AP PS
AP PS co PS co PS co PS
AP PS
Comments
RELEASE GAS
24HR TEST
STARTED 24HR TEST
RELEASE 1915 C.B. STE 130A
HARD LID
EsGil - Corporation
In Partnership witih pmmnent for(2luiliiity Safety
DATE: 5/21/04
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 04-1289
0 APPLICANT
0 PLAN REVIEWER
Q FILE
amQ
SET: I1
PROJECT ADDRESS: 1915 Calle Barcelona Suite 130
PROJECT NAME: Sur La Table - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified it the remarks below are resolved and checked by building
department staff.
and should be corrected and resubmitted for a complete recheck.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
0 The check list transmitted herewith is for your information. The plans are .being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
0 The applicant's copy of the check list has been sent to:
contact person.
w Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1 Fax #:
REMARKS: Applicant to provide a completed special inspection form for field welding and add
notes in red to City Held sets.
Mail Telephone Fax In Person
By: Doug Moody Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 511 3/04 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In Partnership with Government for BuiGiiing Safety
DATE: 4/29/04
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 04-1289
0 PLAN REVIEWER
0 FILE
SET: I
PROJECT ADDRESS: 1915 Calle Barcelona Suite 130
PROJECT NAME: Sur La Table -TI
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list .
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
David Murphy
2101 9* Ave Suite 21 1, Seattle, WA 98121
0 Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: David Murphy d) Telephone #: 206-341-9875 ~203
Date contacted: Y/~?/ov (by: ) Fax #: 206-341 -91 77
Mail delephone1 Fad In Person 0 REMARKS:
By: Doug Moody Enclosures:
Esgil Corporation 0 GA MB 0 EJ PC 4/19/04 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
~~~~
City of Carlsbad 04-1289
4/29/04
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 04-1289
OCCUPANCY: M USE: Retail
TYPE OF CONSTRUCTION: VN ACTUAL AREA: 6382sf
ALLOWABLE FLOOR AREA: STORIES: 1
JURISDICTION: City of Carlsbad
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 4/16/04
HEIGHT:
OCCUPANT LOAD: 179
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/19/04
DATE INITIAL PLAN REVIEW
COMPLETED: 4/ 29/ 04
PLAN REVIEWER: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet number, specification section. etc.
Be sure to enclose the marked UP list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot
City of Carlsbad 04-1289
4/29/04
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commerciallindustrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
1.
2.
3.
4.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2001 edition of the California Building Code (Title 24), which
adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC.
Please provide plans and calculations signed by the California State licensed
engineer or architect for the structural support and lateral bracing of the
stockroom shelving. Include all calculations and finding on the plans. Please
include the California license number, seal, date of license expiration and date
plans are signed. Business and Professions Code.
Please provide plans signed by the California State licensed engineer for the
structural support of the HVAC clearly showing the findings in the calculations.
Please include the California license number, seal, date of license expiration and
date plans are signed. Business and Professions Code.
On the cover sheet of the plans, specify any items requiring special inspection, in
a format similar to that shown below. Section 106.3.2.
0 REQUIRED SPECIAL INSPECTIONS
In addition to the regular inspections, the following checked items will also require
Special Inspection in accordance with Sec. 1701 of the Uniform Building Code.
ITEM
FIELD WELDING
REQUIRED?
YES
REMARKS
5. When special inspection is required, the architect or engineer of record shall
prepare an inspection program which shall be submitted to the building official
for approval prior to issuance of the building permit. Please review Section
106.3.5. Please complete the attached form.
City of Carlsbad 04-1289
4/29/04
6. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I
occupancies. NM cable is restricted (without City approval) to one and two
family dwellings. Note on plans that an equipment ground conductor is to be
installed in all flexible conduits".
7. Show the ampere interrupting capacity (AIC) ratings of the sub-service
equipment. NEC 110-9.
8. Provide complete kitchen hood plans, details, and calculations to show
compliance with UMC, Chapter 5, Part II
a)
b)
c)
Provide the UL listing card showing the exhaust sizing requirements used
for the hoods.
Provide roof framing around new openings in the roof for the exhaust and
make-up air ducts for kitchen hoods.
Clearly show the material used to construct the exhaust duct to be 16
gauge and not 18 gauge. UMC, Sections 508.1.1 & 509.2
9. Please provide the ICBO listing and installation information for the duct wrap
system.
IO. Please review and imprint on the plans the City of Carlsbad Policies and
Procedures for Roof Mounted Equipment to the plans.
1 I. On the plans clearly show the wall and roof insulation locations, thickness, and
R-values, as per the energy design.
12. Please clarify the waste line diagram it appears to show a floor drain at the mop
sink not shown on the floor plans?
13. Please correct the gas line diagram it show the same line to be both 2%'' and 2"?
14. Please provide a detail showing the installation of the gas line to the island cook
top to comply with 121 1.4 of the UPC.
15. Please revise the plans to show a disabled accessible transaction counter located
at a section of counter that is at least 36 long and no more than 28" to 34" high.
Section 1 1228.4.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, Le., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
City of Carlsbad 04-1289
* 4/29/04
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 921 23; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad
9/29/04
04- 1289
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 04-1289
PREPARED BY: Doug Moody DATE: 4/29/04
BUILDING ADDRESS: 1915 Calle Barcelona Suite 130
BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN
1994 UBC Building Permit Fee
1994 UBC Plan Check Fee v
Type of Review: Complete Review 0 Structural Only
0 Other
0 Hourly -1 Hour *
Esgll Plan Revlew Fee
I $539.451
I $464.761
Comments:
Sheet 1 of 1
rnacvalue.doc
To: +I-7607299362 Page 3 of 3 2004-05-26 19:49:29 (GMT) 16233218006 From: Gary Stebbings
05/25/2004 17: 03 2063419177 MURPHYVAREY PAGE 03 2066243775 P.03 . ._-. - NRY-25-2004 15:38 COFFMFlN ENGINEERS-SER
MURPHW4REy PME 03 P. 03
@5/25/2004 15:06 206341921T7
FAX No. 760 602 8558 w'f-24-2uU4 !XIION 08:U AH CITY OF CARSLtlAD . -.
1.
R .n U nu
2.
A.
33,
C.
3.
'AI
B
C.
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST \9\5 ah-
Plan Check No. f,fioLf (m Address , TA&,
Planner Christer Westman Phone (760) 602-461 4
APN:
Type of Project & Use: Net Project Density: DU/AC
Zoning: General Plan: Facilities Management Zone:
CFD (inlout) # Date of participation: Remaining net dev acres:
Circle One
(For non-residential development: Type of land used created by
this permit: 1
Legend: @ Item Complete 0 Item Incomplete - Needs your action
TYPE Environmental Review Required: YES NO -
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required: YES - NO TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone AssessmentlCompliance
Project site located in Coastal Zone? YES- NO-
CA Coastal Commission Authority? - NO YES -
If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite
200, San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt) :
Coastal Permit Determination Form already completed?
If NO, complete Coastai Permit Deteimination Form now.
Coastal Permit Determination Log #: +. .
- YES- NO
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determiqation Log as needed.
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
olio
OUU
uno
oclo
oou
@n
lnclusionary Housing Fee required: YES - NO- (Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
?
Data 'Entry Completed? YES - NO- ($IP/Ds, Actiyity Maintenance. enter CB#, toolbar, SFreens, Housing Fees, .Construct Housing Y /N, Enter Fee UPDATE'' '
t
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow;
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number.
1.
2.
3.
4.
5.
Zoning:
Setbacks:
Front: Required Shown
Interior Side: Reauired Shown
Street Side: Required Shown
Rear: Required Shown
Accessory structure setbacks:
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Structure separation: Required Shown
Lot Coverage: Required Shown
Height: Required Shown
Par king : Spaces Required Shown
Guest Spaces Required Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE DATE 9\44?
H:\ADMIN\COUNTER\BldgPlnc hkRevC hklst
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB 0 qy/ L&' 9 DATE 4-40
RESIDENTIAL TENANT IMPROVEMENT \, .(
RES ID ENTIAL ADDITION M IN 0 R
(<$10,000.00)
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENGINEER DATE
DocsIMislormstPlannin 0 Engineerinp Approvals
Carlsbad Fire Department 041289
1635 Faraday Ave.
Carlsbad, CA 92008
Fire Prevention
(760) 602-4660
Plan Review Requirements Category: Building Plan
Date of Report: 05/18/2004 Reviewed by:
Name: Nadel Architects
Address: 5465 Morehouse Drive Suite 165
City, State: San Diego CA 92121
Job#: 041289 Plan Checker:
Job Name: Sur La Table Bldg #: C6041289
Job Address: 1915 Calle Barcelona Ste. or Bldg. No. 130
Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
0 Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2nd 3rd Other Agency ID
FD Job # 041289 FD File #
Christer Westman
City of Carlsbad Building Department
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-2700
Re: Plan Check Corrections for 1915 Calle Barcelona #130, Plan Check #04-1289
Christer:
The following is in response to Building Department plan review comments received by us on
4/26/04:
i. Signage is not part of this permit. Use raised panel service doors as used elsewhere
within Forum.
Sign contractor has submitted application for sign permit.
We will use raised panel service doors.
2. City of Carlsbad Plumbing - Electrical - Mechanical Worksheet attached.
Completed worksheet is attached.
Thank you,
I/ Karen Hovde
2101 Ninth Avenue Suite 211
Seattle, Washington 98121
T: 206. 341. 9875
F: 206. 341 . 9177
M
Carlsbad Fire Department 041 289
1635 Faraday Ave. Fire Prevention
Carlsbad, CA 92008 (760) 602-4660
t. Plan Review Requirements Cafegory; Building Plan
Date of Report: 04/29/2004 Reviewed by:
Name: Murphy Varey
Address: 2102 9th Ave. Suite 21 1
City, State: Seattle WA 98121
Job#: 041289 Plan Checker:
Job Name: Sur La Table Bldg #: CB041289
Job Address: 191 5 Calle Barcelona Ste. or Bldg. No. 130
0 Approved
Approved
Subject to
Incomplete
The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2nd 3rd Other Agency ID
FD Job # 041289 FD File #
Requirements Category: Building Plan
~~ ~
Requirement: Pending 05.22 Exit Door Hardware
Exit doors shall be openable from the inside without the use of a key or any special knowledge or
effort.
Exception, In group 8 occupancies, key locking hardware may be used on the Main Exit when the
main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or
adjacent to the door stating, "This door to remain unlocked during business hours."
For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is
occupied ."
See item 32 for additional exit door hardware requirements.
1. ALL EXIT DOORS SHALL BE PROVIDED WITH SINGLE ACTION HARDWARE OR PANIC
HARDWARE.
2. ALL DEADBOLT LOCKS SHALL BE DOUBLE CYLINDER. THUMBTURN LOCKSETS ARE
,NOT PERMITTED FOR USE.
Page 1 04/29/04
n
City of Carlsbad Building Department
1635 Faraday Avenue
Carlsbad, CA 92008
(760) 602-2700
Re: Plan Check Corrections for 1915 Calle Barcelona #130, Plan Check#oq-i28g
To Whom It May Concern:
The following is in response to Fire Department plan review comments received by us on
5/4/04:
i. All exit doors shall be provided with single action hardware or panic hardware.
See attached specification sheets.
2. All deadbolt locks shall be double cylinder. Thumbturn locksets are not permitted for use.
See attached specification sheets.
Thank you,
Karen Hovde
2101 Ninth Avenue Suite 211
Seattle, Washington 98121
T: 206. 341 . 9875
F: 206 . 341 . 9177
M
, Carlsbad Fire Department 041289
1635 Faraday Ave. Fire Prevention
Carlsbad, CA 92008 (760) 602-4660
Plan Review Requirements Category: Building Plan
Date of Report: O4/29/*oo4 Reviewed by:
Murphy Varey
2102 9th Ave.
Received
.QarPhy varey ps
Name:
Address: Suite 21 1 My 4 2004
City, State: Seattle WA 98121 m I
Job#: 041289 Plan Checker:
Sur La Table Bldg #: CB041289 - Job Name:
. ...
Job Address: 191 5 Calle Barcelona Ste. or Bldg. No. 130
Approved The item you have submitted for- review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
Specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
I-- 1- Review 2nd 3rd Other Agency ID
FD Job # 041289 FD File #
ReGuiremen fs Category: Building Plan
Requirement: Pending 05.22 Exit Door Hardware
Exit doors shall be openable from the inside without the use of a key or any special knowledge or
effort.
Exception: In group B occupancies, key locking hardware may be used on the Main Exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or
adjacent to the door stating, "This door to remain unlocked during business hours."
For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is
occupied."
See item 32 for additional exit door hardware requirements.
1. ALL EXIT DOORS SHALL BE PROVIDED WITH SINGLE ACTtON HARDWARE OR PANIC
HARDWARE.
2. ALL DEADBOLT LOCKS SHALL BE DOUBLE CYLINDER. THUMBTURN LOCKSETS ARE
NOT PERMITTECW USE. 5- -
Page 1 0412 9/04
Murphy Varey, PS - 2004 SUR LATABLE - THE FORUM AT CARLSBAD 08/03
4. Remote signal capability for connection to remote indicating panel.
B. Manufacturers:
1. Detex Corporation (DTX).
DOOR BOLTS
Door Bolts for Means of Egress Doors: All deadbolt locks shall be double cvlinder. Thumbturn A. I 2-10 locksets are not permitted for use.
B. Bolt Throw: Comply with testing requirements for length of bolts required for labeled fire doors, and
as follows:
1.
2.
3.
4.
5.
Half-Round Surface Bolts: Minimum 7/8-inch (22-mm) throw.
Interlocking Surface Bolts: Minimum 15/i6-inch (24-mm) throw.
Fire-Rated Surface Bolts: Minimum 1-inch (25-mm) throw; listed and labeled for fire-rated
doors.
Dutch-Door Bolts: Minimum 3/4-inch (19-mm) throw.
Mortise Flush Bolts: Minimum 3/4-inch (19-mm) throw.
C. Dustproof Strikes: BHMA A156.16.
D. Surface Bolts: BHMA Ai56.16, Grade i unless Grade 2 is indicated.
1. Flush Bolt Heads: Minimum of i/;?-inch- (13-mm-) diameter rods of brass, bronze, or
stainless steel with minimum 12-inch- (305-mm-) long rod for doors up to 84 inches (2134
mm) in height. Provide longer rods as necessary for doors exceeding 84 inches (2134 mm).
2. Available Manufacturers:
a. Burns Manufacturing Incorporated (BM). b. Don-lo Mfg., Inc. (DJO).
c. Door Controls International (DCI).
d.
e. Hager Companies (HAG).
f.
g. h. Trimco (TBM).
Glynn-Johnson; an Ingersoll-Rand Company (GJ).
IVES Hardware; an Ingersoll-Rand Company (IVS).
Stanley Commercial Hardware; Div. of The Stanley Works (STH).
E. Manual Flush Bolts: BHMA Ai56.16, Grade 1 unless Grade 2 is indicated; designed for mortising
into door edge.
1. Available Manufacturers:
a.
b.
d.
e.
f.
g. h.
i.
C.
i.
Adams Rite Manufacturing Co. (ARM).
Burns Manufacturing Incorporated (BM).
Don-Jo Mfg., Inc. (DJO).
Door Controls International (DCI).
Glynn-Johnson; an Ingersoll-Rand Company (GI).
Hager Companies (HAG).
Hiawatha, Inc. (HIA).
IVES Hardware; an Ingersoll-Rand Company (IVS).
Stanley Commercial Hardware; Div. of The Stanley Works (STH).
Trimco (TBM).
DOOR HARDWARE 08710 - io
F.
2.11
A.
B.
I c-
D.
E.
F.
G.
Automatic and Self-Latching Flush Bolts:
designed for mortising into door edge.
BHMA Ai56.3, Grade i unless Grade 2 is indicated;
I. Available Manufacturers:
a. Cal-Royal Products, Inc. (CRP).
b. Door Controls International (DCI).
c.
d. Hager Companies (HAG).
e.
f. Trimco (TBM).
Glynn-Johnson; an Ingersoll-Rand Company (GJ).
IVES Hardware; an Ingersoll-Rand Company (IVS).
EXIT DEVICES
Exit Devices: BHMA A156.3, Grade 1
Accessibility Requirements: Where handles, pulls, latches, locks, and other operating devices are
indicated to comply with accessibility requirements, comply with the U.S. Architectural &
Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA), Accessibility
Guidelines for Buildings and Facilities (ADAAG)." ANSI Aii7.1.1
I. Provide operating devices that do not require tight grasping, pinching, or twisting of the wrist
and that operate with a force of not more than 5 Ibf (22 N).
Exit Devices for Means of Egress Doors: All exit doors shall be provided with single action hardware
or panic hardware. Comply with NFPA 101. Exit devices shall not require more than 15 Ibf (67 N) to
release the latch. Locks shall not require use of a key, tool, or special knowledge for operation.
Panic Exit Devices: Listed and labeled by a testing and inspecting agency acceptable to authorities
having jurisdiction, for panic protection, based on testing according to UL 305.
Fire Exit Devices: Devices complying with NFPA 80 that are listed and labeled by a testing and
inspecting agency acceptable to authorities having jurisdiction, for fire and panic protection, based
on testing according to UL 305 and NFPA 252.
Outside Trim: Pull with cylinder; material and finish to match locksets, unless otherwise indicated.
I. Match design for locksets and latchsets, unless otherwise indicated.
Available Manufacturers:
1.
2.
3.
4.
5. 6.
7. 8.
9-
10.
11.
12.
13.
14.
Adam Rite Manufacturing Co. (ARM).
Arrow USA; an ASSA ABLOY Group company (ARW).
Cal-Royal Products, Inc. (CRP).
Corbin Russwin Architectural Hardware; an ASSA ABLOY Group company (CR).
Detex Corporation (DTX).
Door Controls International (DCI).
DORMA Architectural Hardware; Member of The DORMA Group North America (DAH).
Dor-0-Matic; an Ingersoll-Rand Company (DOR).
Locknetics; an Ingersoll-Rand Company (LSE).
Monarch Exit Devices & Door Hardware; an Ingersoll-Rand Company (MON).
Precision Hardware, Inc. (PH).
Rutherford Controls Int'l. Corp. (RCI).
SARGENT Manufacturing Company; an ASSA ABLOY Group company (SGT).
Von Duprin; an Ingersoll-Rand Company (VD).
Murphy Varey, PS - 2004 SUR LA TABLE - THE FORUM AT CARLSBAD 08/03
DOOR HARDWARE 08710 - 11
SUR LA TABLE
The Forum at Carlsbad
Carlsbad, California
Calculations
Existing Roof Framing Review
For New Mechanical Equipment
April, 2004
Prepared by:
OFFMAN 1F NGINEERS
1601 Fifth Avenue, Suite 900
Westlake Center Office Tower
Seattle, Washington 9
(206)623-0717 &q I
t 7' st 3'
1
NGINEERS
OFFMAN AF NGINEERS
NGINEERS
I I-
SEE WAJL 3
NOTES I
IOWOE THWMWATS WLOCKABLE COMR AND OW THIS Locanm.PRaVW)~ '7 PFIOGRAMMABLE TSTAT STYLE WECONOMIZER CAPASIUPT. PRovlDE Au WlRNG AND Fiu~Ys.
IM5.02
i
...... .... SHEET NO 1 BY G:..,*HAN!A! RACK DE$IGN & ENGINEERING CO. ................... DATE .............................. 5-3-04 3786 LA CREBCENTA AVE., dUITE 204
GLENDALE, CA. 91208 JOB NO. ....... R.D.78765,. SUBJECT. ...... -. ........ .- -. . TEL:( 81 8)957-2980 FAX:( 81 8)957-8603
SEISMIC ANALYSIS OF STORAGE
PlPP MOBILE SYSTEM FOR:
SUR LA TABLE Received
MA)’ 0 4 2004
19 15 CALLE BARCELONA, SPACE #A 30
CARLSBAD, CA. 92009 Murphy vareyPS
PER CBC 2001 EDITION
STORAGE S H E LVI N G CAPACITY:
100 # / LEVEL
CALCS. 1 THRU 4
DRAWINGS: RD-8765
SH. 1
....................................... SHEET NO 2 BY G. OHANIAN RACK DESIGN & ENGINEERING co. ........... ............ DATE ................................... 5-3-04 3786 LA C'REPC'ENTA AVE., @UITE 204 .. GLENDALE, CA. 91208 JOB NO. ....... RD. -8765...
.......................... SUBJECT. TEL(818)957-2980 FAx:(818)957-8603
1 60" 60"
I I
FIXED SHELVING SIDE VIEW
I, ,, AM
100 # / LEVEL
50 # / BEAM
K 60"~.05 = .3iK a M=
1 60" 60"
I I
MOBILE SHELVING SIDE VIEW
"K S R= = .02<.06 22
BY. ....... G.-...,!?!'!AN!*N...
DATE : 5-3-04 ................................
SU B J ECT. .........................
SHEET NO ........... 3 ............ - GLENDALE, C'A. 91208 JOB NO. ....... R.D.-8765..
RACK DE$IGN & ENGINEERING CO.
3786 LA CREPCENTA AVE., gUITE 204
TEL:(818)957-2980 FAx:(818)957-8603
SEISMIC DESIGN
V=
I= 1
R=5.6
Na=.44
W=D.L.+ L.L.
CEC 2001 SEC. 2222 2.5xCaxl R
I OAD PFR- COI UMN
p= - - 2
W=.05 +.2 E .25 D.L.
COLUMN ANALYSIS
3 1/4'
COMBINED STRESS RATIO
A=.40
i = . oa
Smin=.08
rmin=.54
Q=.75
KSI Fy=36
-
K .02 "K
-c--
.05 *
KSI Fa= 13.6
K Pa =Fa XA = 5.4
Ma =Zln.Fb= 1 .iK
0
=e+ 5 = .32<1.33
Pa Ma I .a
........ .... .... SHEET NO 4 BY 5: oHAN!AN RACK DE$IGN & ENGINEERING CO. ........... ............
................................. 5-3-04 DATE
SUBJECT. ..........................
3786 LA C‘REPC‘ENTA AVE., dUITE 204 RD-8765 .- GLENDALE, C‘A. 91208 JOB NO ...............................
TEL:( 8 18)957-2980 FAX:( 8 18)957-8603
MOMENT AT BEAM CONNFCTION
*K m5+*4 - .45 CONN.= 2 -
2 K v, = ‘25 x3.14 x80~.4=1.5 RIVET 4
K ”K Ma = 1.5 x1.5”x1.33=3.0 CONN
BAsLaAE
STATIONARY SHELVING
K ANCHOR SHEAR = = .03K 2
USE (2)-I /4”@ ANCHOR
PER EASE PLATE, 2” EMB.
3 3/4” 1-1
t=14GA.
OVFRTU RN ING (STATIONARY UNITS)
K “K MOT = .05 ~2~90”~.5~1.15 = 5.2
MR = .25 ~24”= 6 K “K
NO UPLIFT
MOBILE SHELVING
MOBILE TRACK ANCHORD TO FLOOR W/ 1/4”2. ANCHORS Q 24” O.C.
ANTI-TIP BOLTED TO MOBILE CARRIAGE W/ (2) 1/4”2 BOLTS
SHELVING POST CONNECTED TO CARRIAGE W/ (2) 1/4”2 TEK SCREWS PER POST
A- * 3 W
\
I