Loading...
HomeMy WebLinkAbout1915 CALLE BARCELONA; ; PC140019; Permit07-09-2015 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No: PC140019 Building Inspection Request Line (760) 602-2725 Job Address: 1915 CALLE BARCELONA CBAD Permit Type: PLANCK Status: Parcel No: 2550120400 Lot#: 0 Applied: Valuation: $0.00 Construction Type: Entered By: Reference #: Plan Approved: Issued: Project Title: THE FORUM-DIVIDE UP EXISTING Inspect Area: RETAIL SPACE NBAQCK TO COLD/DARK SHELL (CURRENTLY Applicant: KOHN ARCHETECTURE STE 100 9320 CHESAPEAKE DR SAN DIEGO CA 92123 858 274-1812 Owner: T-C FORUM AT CARLSBAD LLC C/O TIAA-CREF 4675 MACARTHUR CT #1100 NEWPORT BEACH CA 92660 FINAL 04/28/2014 RMA 06/26/2014 Plan Check Fee Additional Fees $533.34 $0.00 Total Fees; $533.34 Total Payments To Date: $533.34 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must followi the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information v^ith the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv othenAfise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: OPLANNING •ENGINEERING •BUILDING •FIRE •HEALTH •HAZMAT/APCD ^ CITY CARLSBAD O F Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov I Plan Check No. Est. Value Plan Ck. Deposi Date SWPPP SUITE#/SPACE#/UNrr# APIM '255 -Oil -OH -oo CT/PROJECT# LOT# PHASE# #OFUNiTS # BEDROOIVIS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP M ESCRIPTION OF WORK: Include Sffuare Feet of Affected Area(s) , . Con\;er4 Avi m^'wTu^ CC^<K\\ '^f^t (6o"»4^ ie»5 A\ lo,oai -^r) mv $ '^ftKra^\f EXISTING USE ^ « . < PROPOSED USE , GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIRCONDITIONING FIRE SPRINKIiERS YES|~|# N0| 1 YES QNO Q YES[^fNO| | APPLICANTNAME- Iv- 1 X 1 • _ 1 - ArcUr-iviar-f PROPERTVOWNERNAME ^ t— 1 ^ 1 1 • i ^ ^^bU) CJiy^AdJ^W Dr. 100 1105 CtAlk 5af6-c(toi1A 4 Zc?o ' '""{est) £2.7-^72.c? FAX EMAIL -Ctui^J<^KV( (Pi^i iVJ. j 1/. c<7i7y\ DESIGN PROFESSIONAL / CONTRACTOR BUS. NAME ~ -pop co-TiTLwecRvJ cociilO tajr>£ -?>'C ADDRESS / ADDRESS 7/-^ uJ G- ^ ih^ 37<=> CITY STATE ZIP CITY STATE ZIP PHONE FAX \ PHONE FAX EMAIL EMAIL <^ y\ STATE LiC. # ., ^ATE LiC.# CLASS CITY BUS. LIC.# R TO A/'^V V (Sec. 7031.5 Business and Professions Code; Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a siaied statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a Civil penalty of not more than five hundred dollars {$500)). WORKERS Workers' Compensation Declaration; / hereijy affirm under penalty of perjury one ofthe foiiowing deciarations: • I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this pennit is issued. • I have and will maintain workers' compensation, as required bv Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. p^Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to the Workers'Compensation Laws of Califomia. WARNING; Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damaoes as provided f^ in §^on,3706 of the Labor code, interest and attomey's fees. ^ CONTRACTOR SIGNATURE / hereby afTirm that I am exempt from Contractor's Ucense Law for the following reason: I I I, as owner of the property or my employees with wages as their sole compensalion, will do the wori( and the stmcture is not intended or offered for sale (Sec. 7044, Business and Professions Code; The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements ane not Intended or offered for sale. If, however, the building or Improvemenl is sold within one year of completion, the owner-builder will have Ihe burden of proving that he did not build or improve for the purpose of sale). I I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves Ihereon, and coniracts for such projecis with contraclor(s) licensed pursuant lo the Contractor's License Law). • I am exempt under Section Business and Professions Code for this reason; 1. i personally plan to provide the major labor and materials for consiruction of the proposed property improvement. QVes j iNo 2.1 (have / have not) signed an application for a building pemiit for the proposed work. 3.1 have contracted with the following person (fimi) to provide the proposed consiruction (Include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person lo coordinate, supen/ise and provide the major work (include name / address / phone / contractors' license number): 5.1 will pravide some of the work, but I have conlracled (hired) the following persons lo provide the work indicated (include name / address / phone / type of work); ^PROPERTY OWNER SIGNATURE QAGENT DATE COMPLETE THiS SECTION F O R N O M - R E SI D E M T i A L BUILOiNG PERMITS ONLY Is the applicant or future building occupant required to submit a business plap<asutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acl? Yes f No/ Is the applicant or future building occupant required lo obtain a pemill fronNtie^pollulion control district or air quality management district? Yes No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFiCE OF EMERGENCY SERViCES AND THE AIR POLLUTION CONTROL DISTRICT. C ONSTRUCTION LENDING A 4S i M C I hereby affirm that there is a construction lending agency for the performance ofthe work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certify that 1 have read the application and state ttiat the above infbnnaton is conect and tliat the infbimation on ttie plans is accurate. I agree to compiy witti aii Ci^oidlnances and State iaws relating to buiiding constmctton. I hereby authorize repnssentative of the City of Cartsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HAf^LESS THE CfTY OF CARLSBAD AGAINST Aa LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: Afl OSHA permit is required for excavations over SO' deep and demolitbn or construction of structures over 3 stories in height. EXPIfRATION: Every permit issued by the Buikjing Official under the pnovisions of this Code shall expire by limitation and become null and void if the building or authorized by such pemnit is not commenced within 180 days fiom the date of such pemiit or if the buildinaprwori( authorized by such p^it is suspended or abandoned at any time after the wori< is commenced for a period of 180 days (Sectbn 106.4.4 Uniform Building Code). ygf APPLICANT'S SIGNATURE iibinaorwork authonzed by sucf DATE 20 April STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email buildina(5)carlsbadca.gov or Mali the completed forni to City of Carlsbad, Bullding Division 1635 Faraday Avenue, Carlsbad, Califbmia 92008. C0#: (Office Use Oniy) CONTACT i«IAME OCCUPANT NAiVIE ADDRESS BUILDING ADDRESS CITY STATE ZIP CiTY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAILTO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) IVIAIL/FAX TO OTHER: ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION >eS'APPLICANT'S SIGNATURE DATE EsGil Corporation In PartnersHip witH government for (BuiCtfing Safety DATE: 06/06/2014 • APPLICANT • JURIS. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLAN CHECK NO.: PC14-0019 SET: II PROJECT ADDRESS: 1915 Calle Barcelona Suite 134 PROJECT NAME: The Forum TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: 1X1 EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person • REMARKS: By: John Le Vey Enclosures: EsGil Corporation • GA • EJ • MB • PC 06/02/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (PartnersHip witH government for (BuiCcCing Safety DATE: 05/07/2014 •APPLICANT ^aTjURis. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLAN CHECK NO.: PC14-0019 SET: I PROJECT ADDRESS: 1915 Calle Barcelona Suite 134 PROJECT NAME: The Forum TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: Kohn Architecture 9320 Chesapeake Dr. Suite 100 San Diego Ca, 92123 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IX EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kohn Architecture Telephone #: Date contacted: (by: ) Email: steven(gkhondesign.com Fax #: y^Mail ^ iTelephone Fax In Person • REMARKS: By: John Le Vey Enclosures: EsGil Corporation • GA • EJ • MB • PC 04/29/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 Carlsbad PC 14-0019 05/07/2014 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PC14.0019 JURISDICTION: Carlsbad OCCUPANCY: M USE: Retail TYPE OF CONSTRUCTION: VB ACTUAL AREA: 10,067 ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: 35' SPRINKLERS?: yes OCCUPANT LOAD: unknown REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 04/28/2014 DATE PLANS RECEIVED BY ESGIL CORPORATION: 04/29/2014 DATE INITIAL PLAN REVIEW COMPLETED: 05/07/2014 PLAN REVIEWER: John Le Vey FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required priorto the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval ofthe plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. Carlsbad PC 14-0019 05/07/2014 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Section 109.3 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide the designer's or contractor's construction cost estimate of all work proposed. 2. Please provide a complete vertical and lateral analysis for the proposed project. 3. Each sheet of the plans must be signed by the person responsible for their preparation, California State Law. 4. Please provide a note that the store front for suite 134 will be under a separate tenant improvement permit. If the new store front is to be installed provide ENV forms to show the new glazing. 5. Please provide connections to the new jamb and head tracking for the new store front, if the new store front is to be installed, the details do not clearly show connections on sheet A5 details 5 and 6. 6. Please provide an electrical single line diagram, show grounding, working clearances, AlC to be consistent throughout. 7. Please show the restrooms that serve the area of improvement to be accessible, provide dimensions. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Carlsbad PC 14-0019 05/07/2014 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please brieflv describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: • Yes • No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact John Le Vey at Esgil Corporation. Thank you. • Carlsbad PC 14-0019 05/07/2014 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: PC14-0019 PREPARED BY: John Le Vey DATE: 05/07/2014 BUILDING ADDRESS: 1915 Calle Barcelona Suite 134 BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl cost estimate 92,000 Air Conditioning Fire Sprinklers TOTAL VALUE 92,000 Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: [Zl Complete Review $656.42 $426.67 • Structural Only J]I]^Repetitive Fee ~"i Repeats • Other |—j Hourly EsGil Fee Hr. @ * $367.60 Comments: Sheet 1 of 1 macvalue.doc + PLAN CHECK PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www.carlsbadca.gov DATE:04/30/14 PROJECT NAME: THE FORUM PROJECT ID: CB14-0959 PLAN CHECK NO: 1 SET#: ADDRESS: 1915 CALLE BARCELONA STE 133 APN: 255-012-04 VALUATION: $30,698 / This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: KATHLEEN LAWRENCE 04/30/14 A Final Inspection by the Division is required Yes / No This plan check review is NOT COMPLETE. Itenns nnissing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: STEVEN@KOHNDESIGN.COIVI You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. for questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 Chris.Sexton@carlsbadca.gov / Kathleen Lawrence ^ 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Grefiorv.Rvan@carlsbadca.fiov Gina Ruiz Gina.Ruiz@carlsbadca.gov Linda.Ontiveros@carlsbadca.fiov Cynthia.Wonfi@carlsbadca.fiov Dominic.Fieri@carlsbadca.gov Remarks: NO ENG FEES NO CHANGE IN USE •5. CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-28 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov DATE: 6/4/14 PROJECTNAME: T.l. PROJECTID: PLAN CHECK NO: PC140019 SET#: ADDRESS: 1915 CALLE BARCELONA APN: ^ This plan check review is complete and has been APPROVED bv the PLANNING Division. By: A Final Inspection by the PLANNING Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. Q This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: STEVEN@K0HNDESIGN.COM For questions or clarifications on the attached checklist piease contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERiNG 760-602-2750 FIRE PREVENTION 760-602-4665 Chris Sexton 760-602-4624 Chrls.Sexton@carlsbadca.gov I I Kathleen Lawrence 760-602-2741 Kathleen.La wrence@carlsbadca.fiov 1 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov X Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.fiov Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov • • 1 I Dominic Fieri 760-602-4664 Domlnic.Fieri@carlsbadca.gov Plan Check No. PC140019 Address 1915 CALLE BARCELONA Date 6/4/14 Review # 2 Planner GINA RUIZ Phone (760) 602- 4675 Type of Project & Use: LL Net Project Density: DU/AC Zoning: P-C General Plan; R/O/RMH Facilities Management Zone: 23 CFD (in/out) # 1 Date of participation: 5/14/1996 Remaining net dev acres: (For non-residential development: Type of land use created by this permit: ) REVIEW #: 12 3 Legend: ^ Item Complete • Item Incomplete - Needs your action S • • Environmental Review Required: YES • NO |E1 TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: lEI • • Discretionary Action Required: YES • NO |EI TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? if not, state conditions which require action. Conditions of Approval: • • Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES El NO Q CA Coastal Commission Authority? YES Q NO El If Catifornia Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): EXEMPT • • Habitat Management Plan Data Entry Completed? YES • NO E If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) • • Inclusionary Housing Fee required: YES • NO El (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Tracking Form (form P-20) completed: YES • NO • N/A El p-28 Page 2 of 3 07/11 Site Plan: EDO City Council Policy 44 - Neighborhood Architectural Design Guidelines EDO 1 • Applicability: YES • NO E E • • 2. Project complies: YES • NOO Zoning: • • • • EDO • ED Setbacks: Front: Interior Side: Street Side: Rear: Top of slope; Required Required Required Required Required 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear; Structure separation: 3. Lot Coverage; Required Required Required, Required Required. Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown, Shown Architecture Compatibility; Required MUST BE CONSISTENT WITH ORIGINAL ARCHITECTURE PLANS Shown REMOVAL OF GABLE ROOF REPLACING WITH FLAT IS NOT CONSISTENT. SEE BELOW FOR MORE INFORMATION. PER REVIEW OF THE PROPOSED CHANGES TO THE FIRST SUBMITTAL TO COMPLY WfTH ARCHITECTURAL COMPATIBILITY. THE FORUM PLANNER & CITY PLANNER ACCEPTED MODIFICATIONS ON 5/13/14. EDO • ED Spaces Required, Shown 5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Commonts #1. PER SHEET A 3. THE REMOVAL OF THE GABLE ROOF ANO REPLACEMENT WITH A FLAT ROOF LINE IS NOT CONSISTENT WITH THE ORIGINAL ARCHITECTURE PLANS, NOR IS IT SUPPORTED BY STAFF. PLEASE REVISE THE PLANS. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER GINA RUIZ DATE 6/4/14 P-28 Page 3 of 3 07/11 Steven Kohn From: Gina Ruiz [Gina.Ruiz@carlsbadca.gov] Sent: Tuesday, May 13, 2014 3:28 PM RECORD PODV To; steven@kohndesign.com • •••WWni^ wwr • Subject: RE; PC140019-1915 CALLE BARCELONA Christer discussed the revisions with the City Planner and they came to the conclusion that the revisions are acceptable. Please revise the plans accordingly and resubmit directly to the Building Division as part of your Building Permit resubmittal. They will internally route it back to me for review. Please let me know if you have any further questions. City of Carlsbad Gina Ruiz Planning Technician II Planning Division City of Carlsbad 1635 Faraday Ave. Carisbad, CA 92008 www.carlsbadca.gov P: 760-602-4675 F: 760-602-8558 gina.ruiz(5) carlsbadca.gov From: Steven Kohn fmailto:steven@kohndesign.com] Sent: Monday, May 12, 2014 5:19 PM To: Gina Ruiz Subject: RE: PC140019-1915 CALLE BARCELONA KOHN ARCHITECTURE A PROFESSIONAL CORPORATION 9320 CHESAPEAKE DR. SUITE 100 SAN DIEGO, CALIFORNIA 92123 858.274.1812 / 858.227.5720 (FAX) Gina, Thank you for affording us the opportunity to address this issue through plan check. After conferring with the owner, we have made changes to the architecture which I believe stay true to the spirit of the original design. CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 06/27/14 PROJECTNAME: shell PLAN CHECK N0:pcl40019 SET#: I PROJECT ID: ADDRESS: 1915 calle barcelona APN: ^Opy ^ This plan check review is connplete and has been APPROVED by the flre Division. By: cwong A Finai Inspection by the Division is required El Yes • No Q This pian check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: OTC appointment for 6/25/14 set (hard copy sent via USPS) Vou may a/so have corrections from one or more of the divisions Usted below. Approval from these divisions may be required prior to the issuance of a building permit Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marl<ed: 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.eov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.^ov 1 1 Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.eov 1 1 Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov X Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.eov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fleri@carlsbadca.gov Remarks: 6/27/14 **APPROVED: Page 1 of 2 THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. 6/25/14 ***Bubble Ali Changes*** 1. Sheet A-1. Demising waii detail calls out (2) sheets 5/8' Type X gypsum Board. This wiii go back to original 1 hr wall between tenants to be consistent with remainder of mall as built. Label on plans. This may be done with an appointment. This is set for 9:00 AM on Friday with Steven Kohn. Page 2 of 2 Carlsbad Fire Department Plan Review Requirements Category: PLANCK Date of Report: 06-27-2014 Reviewed by: Q^A^iJ Name: Address; KOHN ARCHETECTURE STE 100 9320 CHESAPEAKE DR SANDIEGO CA ATTN:STEVEN 92123 Permit #: PC140019 Job Name: THE FORUM-DIVIDE UP EXISTING Job Address: 1915 CALLE BARCELONA CBAD TNrfTUPm IU iH^JMW UAii Huu^uiiiim|||| ll ' ' iiii[Hin||,ili I '.this qffice cannot adequately conduct a n n ^ In rii li'ltiiiin i niiijili iin with the applicable coHerSBd^r-^dandards. Please review carefully all mj^xuiwrrrrs attar.hpH Please resubmit the necessary plans and/or specifications, witlTChsa^^^^'clouded", to this office for review and approval. Conditions: Cond: CON0007399 [NOT MET] ***Bubble All Changes*** 1. Sheet A-1. Demising wall detail calls out (2) sheets 5/8' Type X gypsum Board. This will go back to original 1 hr wall between tenants to be consistent with remainder of mall as buih. Label on plans. This may be done with an appointment. This is set for 9:00 AM on Friday wdth Steven Kohn. Cond: CON0007404 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 06/27/2014 By: cwong Action: AP SLDa DEPT COPY RECOMMENDED FOR APPROVAL Daryl K. James & Associates, Inc. ^^JL/ Op Chptked by: ROBERT SCOTT c' & Date: June 9. 2014 APPUCANT: Kohn Architecture JURISDICTION: Carlsbad Fire Department PROJECT NAME: Retail Space Conversion PROJECT ADDRESS: 1915 Calle Barcelona Mercato PROJECT DESCRIPTION: PC140019, T.l. of 10,067^ of existing retail store - currently suite 135. Convert space into 3 separate suites; numbered and square footage for each suite as follows: Suite #133 at 827 sq. feet; suite #134 at 6,023 sq. feet; and suite #135 at 3,217 sq. feet. Work includes revert original area back to shell space and new entry/exit for end suite; replace gable roof fagade-and install parapet, install new demising walls; also HVAC, electrical work. The items below have all been corrected or clarified. CB140019 is recommended for approval for permit issuance. II -Revise Section for titled 'Fire Notes' and retitle as 'Deferred Submittals': Provide the following list of Deferred Submittals -Fire Sprinkler System - 2013 CFC 903 and 2013 NFPA 13 -Fire Alarm System - 2013 CFC 907 and 2013 NFPA 72, including CFC 907.2. ADD the following Information section to reflect current codes: -Ust of Applicable Codes in Code Information: 2013 California Building Code based on ttie 2012 International Building Code 2013 California Fire Code based on the 2012 International Fire Code 2013 California Electrical Code based on the 2012 National Electrical Code 2013 California Mechanical Code ...based on the 2012 Uniform Mechanical Code 2013 California Plumbing Code based on the 2012 Uniform Plumbing Code 2013 California Energy Code T1-cont. -Add note that reads: a C-16 licensed fire protection contractor shall perform all fire sprinkler system work. A C-10 licensed fire alarm contractor shall perform all fire alarm system work. No fire protection system work shall be performed without fire dept. approved plans. The contractor shall notify the fire department if fire sprinkler system will be out of service overnight. -Add Note to read: Each suite shall be equipped with one fire extinguishers rated at 2A-10BC. Maximum Travel distance to fire extinguishers shall not exceed 75 feet. All fire extinguishers shall be mounted in accessible and visible location, not to exceed 5 feet above finished floor to top of extinguisher. CFC 906. A2 Hardware general notes; revise note for sign above door and provide to read as follows: -THIS DOOR SHALL REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED'. Minimum one-inch high letters are required. A sign is required on each suite door that is equipped with a double-cylinder keyed deadbolt. -Add note: the means of Egress in each suite shall be illuminated at all times building space is served, in accordance with and as required by CA. Building Code, Section 1006.1; 1006.2.,1006.3. A-3 Add Note: Address numbers shall be mounted on building in visible location. Numbers shall be minimum 12 inches in height, with 1-1/2 Inch stroke and contrast in color to background. **Show location of proposed numeric address on building. CBD 17.04.320 A-4 Add Notes to Roof Plan: -Imprint Carlsbad Policy 80-6 on to roof plan. -Provide a note that Intent B (Fireman Safety) will be provided on roofs of new buildings. Recommend Approval R. Scott 4 ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL ^7 Community & Economic Development Department k^ 1635 Faraday Avenue '<Jf^ Carlsbad CA 92008 ^ y^^ww.carlsbadca.gov — DATE: 06/25/14 PROJECTNAME: shell PLAN CHECK N0:pcl40019 SET#: 1 PROJECT ID: ADDRESS: 1915 calle barcelona APN: Q This plan check review is compiete and has been APPROVED by the fire Division. By: cwong ^ A Final Inspection by the Division is required |^ Yes • No ^ This pian check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: OTC appointment for 6/25/14 set (hard copy sent via USPS) you may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on ttie attached checklist please contact the following reviewer as marked: 1 1 Chris Sexton 760-602-4624 Chrls.Sexton@carlsbadca.gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov 1 1 Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Glna.Rulz@carlsbadca.gov 1 1 Linda Ontiveros 760-602-2773 Llnda.Ontiveros@carlsbadca.^ov X Cindy Wong 760-602-4662 Cvnthla.Wong@carlsbadca.gov • • 1 1 Dominic Fieri 760-602-4664 Domlnlc.Flerl@carlsbadca.gov Remarks: 6/25/14 ***Bubble All Changes*** Page lofl 1. Sheet A-1. Demising wall detail calls out (2) sheets 5/8' Type X gypsum Board. This wiii go back to original 1 hr wall between tenants to be consistent with remainder of mall as built. Label on plans. This may be done with an appointment. This is set for 9:00 AM on Friday with Steven Kohn. Page 2 of 2 Carlsbad Fire Department Plan Review Requirements Category: PLANCK , Date of Report: 06-25-2014 Name: Address: KOHN ARCHETECTURE STE 100 9320 CHESAPEAKE DR SANDIEGO CA ATTN:STEVEN 92123 Permit #:PC140019 Job Name: THE FORUM-DIVIDE UP EXISTING Job Address: 1915 CALLE BARCELONA CBAD Reviewed by: INCOMPLETE The item you have submitted for review is incomplete. At this time, this office caimot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0007399 [NOT MET] Bubble All Changes*** 1. Sheet A-1. Demising wall detail calls out (2) sheets 5/8' Type X gypsum Board. This will go back to original 1 hr wall between tenants to be consistent with remainder of mall as built. Label on plans. This may be done with an appointment. This is set for 9:00 AM on Friday with Steven Kohn. I'age 1 or z CORRECTION LIST BLDG, DEPT COPY Daryl K. James & Associates, Inc. Checked by: ROBERT SCOTT Date: Mav 19. 2014 APPLICANT: Kohn Architecture JURISDICTION: Carlsbad Fire Department PROJECT NAME: Retail Space Conversion PROJECT ADDRESS: 1915 Calle Barcelona Mercato PROJECT DESCRIPTION: PC 14-0019, T.l. of 10,067a] of existing retail store - currently suite 135. Convert space into 3 separate suites; numbered and square footage for each suite as follows: Suite #133 at 827 sq. feet; suite #134 at 6,023 sq. feet; and suite #135 at 3,217 sq. feet. Work includes revert original area back to shell space and new entry/exit for end suite; replace gable roof fa?ade-and install parapet, install new demising walls; also HVAC, electrical work. This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. INSTRUCTIONS FOR EXPEDITED PLAN REVIEW SERVICE • CORRECTIONS OR MODIFICATIONS TO THE PLANS MUST BE CLOUDED AND PROVIDED WITH NUMBERED DELTAS AND REVISION DATES ALONG WITH A DESCRIPTIVE NARRATIVE OF CORRECTIONS ADDRESSING ALL COMMENTS. PLEASE BE SURE TO PUT FIRE REVISIONS ON THE BUILDING DEPT. PLAN CHECK SET. - PLEASE DIRECT ANY QUESTIONS REGARDING THIS REVIEW TO: ROBERT SCOTT 760- 402-3976 OR FYRWISE07@GMAIL.COM • CORRECTED PLANS, DESCRIPTIVE NARRATIVE OF REVISIONS FOLLOWING EACH COMMENT ON THIS FORM, AND A COPY OF BUILDING DEPARTMENT (ESGIL) - ONE COMPLETE PLAN CHECK SET (initial or revised) MUST BE DELIVERED DIRECTLY TO THE FOLLOWING ADDRESS TO AVOID DELAY: ROBERT SCOTT 4906 CHAUCER AVE SAN DIEGO, CA. 92120 COMMENTS - Additional comments made shall be generated by response on revised set and Clouded 11 -Revise Section for titled 'Fire Notes' and retitle as 'Deferred Submittals': Provide the following list of Deferred Submittals -Fire Sprinkler System - 2013 CFC 903 and 2013 NFPA 13 -Fire Alarm System - 2013 CFC 907 and 2013 NFPA 72, including CFC 907.2. Fage z or z II ADD the following Information section to reflect current codes: -List of Applicable Codes in Code Information: 2013 California Building Code based on the 2012 International Building Code 2013 California Fire Code based on the 2012 International Fire Code 2013 California Electrical Code based on the 2012 National Electrical Code 2013 California Mechanical Code ...based on the 2012 Uniform Mechanical Code 2013 California Plumbing Code based on the 2012 Uniform Plumbing Code 2013 California Energy Code -Add note that readsia C-16 licensed fire protection contractor shall perform all fire sprinkler system work. A C-10 licensed fire alarm contractor shall perform all fire alarm system work. No fire protection system work shall be performed without fire dept. approved plans. The contractor shall notify the fire department if fire sprinkler system will be out of service overnight. -Add Note to read: Each suite shall be equipped with one fire extinguishers rated at 2A-10BC. Maximum Travel distance to fire extinguishers shall not exceed 75 feet. All fire extinguishers shall be mounted in accessible and visible location, not to exceed 5 feet above finished floor to top of extinguisher. CFC 906. A2 Hardware general notes; revise note for sign above door and provide to read as follows: -THIS DOOR SHALL REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED". Minimum one-inch high letters are required. A sign is required on each suite door that is equipped with a double-cylinder keyed deadbolt. -Add note: the means of Egress in each suite shall be illuminated at all times building space is served, in accordance with and as required by CA. Building Code, Section 1006.1; 1006.2., 1006.3. A-3 Add Note: Address numbers shall be mounted on building in visible location. Numbers shall be minimum 12 inches in height, with 1-1/2 inch stroke and contrast in color to background. **Show location of proposed numeric address on building. CBD 17.04.320 A-4 >4dd Notes to Roof Plan: -Imprint Carlsbad Policy 80-6 on to roof plan. -Provide a note that Intent B (Fireman Safety) will be provided on roofs of new buildings. MESRI ENGINEERING STRUCTURAL CONSULTING PROJECT; FACADE REMODEL AT #134.1915 CALLE BARCELONA. CARLSBAD. CA ROOF LOADS (FLAT); ROOFING 3.0 (NO GRAVEL) PLYWOOD 1.8 RAFTERS 3.0 CLO. + INSULATION 3.0 SPRINKLER 2.0 MISC. 2.2 ROOF LOADS fSLPOED); MANSARDS / TOWERS ROOFING 12.0 PLYWOOD 1.8 RAFTERS 3.0 CLG. + INSULATION 0.0 SPRINKLER 0.0 MISC. 1.2 DEAD LOAD LIVE LOAD TOTAL LOAD WALL (EXT.): 16.0 PSF WALL (INT.): 10.0 PSF 15.0 PSF DEAD LOAD 20.0 PSF LIVE LOAD 35.0 PSF TOTAL LOAD AT TOWERS ADD CLG LOAD, AND STUCCO AS REQIJIRED=10.0 PSF 18.0 PSF 20.0 PSF 138.0 PSI^ BEAMS: #1 POSTS: #1 • • • • • • JOIST & I?l!tftiaiSG:#2 Ol.Si , J , STUDS & PLATES: #2 OR # 1 fcltONi • • • • ALL CONCRETE TO BE A MIN. OF 3000 PSI AT 28 DAYS STRENGTH. (SEE PLANS FOR SPECIAL INSPECTION REQUIREMENTS) Ss =1.089 Fa = 1.064 Sins=I. 159, Sds = 0.773, R=6.5, 1=1.0, SFTE CLASS D, P=l.3 WIND: CBC20I3 EXP. B, 110 MPH, 3 SBC GUST SOIL PRESSURE: 1500 psf @ 18" BELOW GRADE BY: CBC MIN. THESE CALCULATIONS ARE NOT VALID OR USABLE WITHOUT THE WET SIGNATURE OF ONE OF THE PRINCIPALS OF THE MESRI ENGINEERING. THESE CALCULATIONS ARE ONLV FOR THE ITEMS INCLUDED HEREIN. SPECIFIED BY THE CLIENT AND DO NOT IMPLY APPROVAL OF ANV OTHER PART OF THE STRUCTURE BY THIS OFFICE. JOB NO.: 0.001416 DATE: 04-21-14 DESIGNED BV: M.M CHECKED BY P {^i?/>.sT ^^vv^--^ ^^\Q3r5' • • • • • • • • • • • • • • • 4^ K^^^.^i^.^-^^-"-' «««« »«««« • • • ytdJj^m • • • • •••• •••• -1b> 1 I'M- X ^S" To specify your title block on these five lines, use the SETTINGS main menu selection, choose the Printing & Title Block tab, and ent your title block Information. Title: Dsgnn Description; Scope: Date: Job# 2:33PM, 21 APR 14 Rev- 560100 Uaar. KW-0604834. Var S.6.1.25-Ocl-20()2 Single Span Beam Analysis e\e»ailertliohrtttil3« facade imedtReanepy b " ' ' Description CANOPY BEAM General Information Center Span Left Cantilever Right Cantilever 36.00 ft ft ft Moment of inertia Elastic Modulus Beam End Rxity 7.080.000 In4 1,700 ksi Pin-Pin Uniform Loads \ On Center Span.. #1 0.349 k/ft On Left Cantilever... #1 m On Right Cantilever... #1 k/ft Point Loads Ij Magnitude Location 2.613 k 9.000 ft k ft k ft k ft k ft* Ct !. V V Query Values O ... ^ , •1 Center Location Moment Shear Deflection 0.000 ft 0.00 k-ft 8.24 k 0.00000 in Left Cant 0.000 ft 0.00 k-ft 0.00 k 0.00000 in RlghsCaot 0.000 ft 0 00. k-ft O.OOCCOJP Moments... Max + @ Center Max - @ Center @ Left Cant @ Right Cant 68.91 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft at at 16.16ft 0.00 ft Shears... @Left ©Right Maximum Deflections... 8.24 k 6.94 k 8.24 k I^AItoTi6.. @Left @ Right ©Center -1.347 in at 17.60 ft Maximum = 68.91 k-ft @ Left Cant. 0.000 in at 0.00 ft @ Right Cant 0.000 in at 0.00 ft '8.24 k 6.Mk 1- 2.$fk [iriiTmiTTn iTmTfmiTfTiiTMTTTiTnn] 36.00 ft Mmax = 68.90 k-ft at 16.16 ft from left Pmax = -1.3472 in at 17.60 ft from left Ri = 8.241 k vmax® left =8.241 k • • • • • • .. • Rr = 6.9^k *Vmax$(tj:^^Sk • t 3_ To specify your title block on these five lines, use the SETTINGS main menu selection, choose the Printing & Title Block tab, and ent your title block Infbrmation. Titte: Dsgnr: Description: Scope: Job# Date: 2:35PM, 21 APR 14 Rev 560100 Uur IWM)604834, var S.6.1,2S4}cl-2aa2 (0)1903-2002 ENERCALC Englnearina Software Single Span Beam Analysis gVc«d)ile«\kehrtM>134 toda remodrtVanopy b Description CANOPY BEAM General Infbrmation Center Span Left Cantiiever Right Cantiiever 36.00 ft ft ft Moment of Inertia Elastic Modulus Beam End Fixity 7,080.000 in4 1,700 ksi Pin-Pin Uniform Loads On Center Span... #1 0.329 k/ft On Left Cantilever.. #1 k/ft On Right Cantilever... #1 Point Loads Magnitude Location 1.240 k 9.000 ft k ft Query Values 0.000,ft o^qp.ii-ft ).00(JO,0,i{i Center Location lament Shear Deflection IMoments... Max + @ Center Max - @ Cenier igl Left Cant @ Right Cant 0.000 ft 0.00 k-ft 6.85 k 0.00000 In Left Cant 0.000 ft 0.00 k-ft 0.00 k 0.00000 in •••••• Riglf Ca(t ; • • • • • •—•— 59.02 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft at at 17.03 ft 0.00 ft Shears... @Left @ Right Maximum Deflections... 6.85 k 6.23 k 6.85 k • • • • • Reaotlo«w«.* (gLeft ©Right 6.a»k* @ Center -1.152 in at 17.82 ft Maximum = 59.02 k-ft @ Left Cant 0.000 in at 0.00 ft @ Right Cant 0.000 in at 0.00 ft 4- • • I toAo ^z-ia^ 5^-2,0./ ... A • • • • • • • • • • • • • • • • • • • • • • • • • • • • • / As / \ (01 Design Maps Summaiy Report Page 1 of 1 Design Maps Summary Report User-Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS lia^sftl data available in 2008) Site Coordinates 33.0709°N, 117.26535°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III • mapquest \ USGS-Provided Output Ss = 1.089 g Sl = 0.420 g SMS — SMI — ncinitas Solana Beach ®2014F Esco NORTH: AMERICA t- I' * • • • • • • • »»»» t • • . a • a a a • a a a a a a a a a a a '^AapQiwst a a a a a < 1.159 g 0.664 g Sos = 0.773 g Sox = 0.442 g a a a a a a a a a For information on how the SS and Sl values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCEn Response Spectrum R Vt 0.20 « io o.co oao 1.00 >.20 1 40 I.co i.ao ;oa Period. T(sec) Design Response Spectrum n i)On 0 2<. 0 40 0 to 0 «0 t 00 1 iO I «0 t CO Period. T(sec) .so 2 00 Although this information Is a product of the U.S. Geological Survey, we provide no warranty, expressed or iin|)iied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge. http://ehp4-earthquake.cr.usgs.gov/designmaps/us/summary.php?... 4/21/2014 Latitude and Lormitudc of a Point Paae 2 of 2 1 I Clear / Reset Remove Last Blue Marker Center Red Marker Get the Latitude and Longitude of a Point When you click on the map, move the marker or enter an address the latitude and longitude coordinates of the point are inserted in the boxes below. Latitude: 33.070897 Longitude: :-ii7.265347 Show Point from Latitude Longitude Use this if you know the latitud coordinates of a point and war on the map the point is. Use: + for N Lat or E Long 1/1/Long. Example: +40.689060 -74.04 Note: Your entry should not he embedded spaces. . Decimal Deg'I'^^itude:'. Decimal Deg.etongitud^*. hltp://itouchmap.com/latlong.htnil 4/21/2014 /^Ay:?^^^^^ fn^a-tr - ^^^^ / a ^ aa'aa* • ^ alaa a aaa aaaa • a aaaa CJT • a aaaa aaa a a a a a aaaa < M 'z^5-is a... ; a^aaa a a a a aaaa aaaa G? at S 52 TTPIOAU I?ETAILS 53 5HEAR PANEL SCHEDUUE 54 ROOF FRAMING PLAN - FOUNDATION PLAN 55 BUILPIN6 5ECTION5 56 STRUCTURAL DETAIL5 EUftiBlblfix PI PLUMBINO PLAN n rrrTwirriM i El ELECTRICAL COVER SHffiT E2 POi« PLANS BUUMNO SUMMARY JURISPI^TIPN. THE CITY OF CARLSBAI? APPLICABLE COPESi THIS PROJECT SHALL COMPLY WITH THE 20IS CALIFORNIA BUILPIN6 COI?E, WHICH ADOPTS THE 20I2 IBC, 20I2 Uh4C, 20I2 UPC, AND THE 20II NEC. OCCUPANCY &ROUP. M (HERCANTILE^ 95'-0" OVERALL HEKSHT ABOVE FINISH FLOOR. WMBER OF STSBlKi. I CONSTRUCTION TYPE. V/B (FULLY SPRINKLERED; BASIC ALLOWABLE BUILDING AREA. IPOO SOUARE FEET ?WABLE BUILDINtS AREA. UNLIMITH? (PER CB.C. SECTION 5050) EXISTIN<& BUILDINGS AREA. l7jS02 SQUARE EXISTIN© SUITE ISO TO REMAIN. EXISTING SUITE 132 TO REMAIN. EXISTINA 9UI1E 199 TO BE DMPEDi NEW SUITE 133. NEW SUITE 134. NEW SUITE 135. 6S05 SF IPSS SF lOjOeTSF 527 SF 6P25 SF 3217 SF C(i,iqoUl VICNTY MAP r y to Son Dlaao / toLA K WIS CALLE BARCELONA, SUITES 134,135,136 CARLSBAD, CALIFORNIA ^2026 LOT 4 OF CITY OF CARLSBAD TRACT NO. ^2-05, ©RffiN VALLEY, IN THE CITY OF CARLSBAD, COWTY OF SAN DIESO, STATE OF CALIFORNIA, ACCORDING TO MAP THEREOF NO. I3«!^T, AS FILED IN OFFICE OF THE COUNTY FECC7RDER. OF SAN DIEGO COUNTY, DATED JULY IO, 2000 AS FILE NO. 2000-3625M. ASSESSOR'S PARCEL NUMBERS. 255-OI2-04 SCOPE CJF WC3RK DEMISE A SUITE IN AN EXISTING THRffi-TENANT BUILDING INTO THRffi SEPARATE SUITES FOR A TOTAL OF FIVE INDIVIDUAL RETAIL SUITES. REMOVE EXISTING INTERIOR CEILINGS, FURNISHINGS, FIXTURE, FINISHES, HVAC DISTRIBUTION, PLUMBING, AND ELECTRICAL CONSTRUCTED BY TWE ORIGINAL TENANT. AI?D A NEW STOREFRONT ENTRY AND EXIT ACCESS FOR THE NEWLY-CREATED END-CAP SUITE. RE-DKIGN THE ELECTRICAL SWITCHGEAR TO SERVICE THE NEW SUITES BY REPLACING A SINGLE ©OOA SERVICE WITH TWO 400A SERVICES; AND USING AN AVAILABLE 200A METER SOCKET. REPLACE EXISTING GABLE ROOFED FACADE WITH A NEW PARAPET AND SOFFIT THAT WILL ACCOMMODATE THE PROPOSED TENANT'S STOREFRONT fSUBMITTED UNDER SEPARATE PERMIT;. AJtOtiTgCTUaAL. Tl PROJECT INFORMATION Dl DEMOLITION PLAN D2 DEMOLITION REFERENCE PLANS Al BUILDING FLOOR PLAN A2 STOREFRONT DEMOLITION A3 NEW STOREFRONT ELEVATION A4 ROOF AND SOFFIT PLAN A5 SECTIONS gTTWWKALi 51 TYPICAL NOTES Sl.l SPECIAL INSPECTION 52 TYPICAL DETAILS 53 SHEAR PANEL SCHEDULE 54 ROOF FRAMING PLAN - FOUNDAT 55 BUILDING SECTIONS 56 STRUCTURAL DETAILS PI PLUMBING PLAN n ITrTKirrfN I El ELECTRICAL COVER SH^T E2 POWER PLANS I ARCHITECT KOHN ARCHITECTURE <!320 CHESAPEAKE DRIVE, SUITE lOO SAN DIEGO. CA <^2I23 PRACTICAL DESIGN ENGINKRING BLACK MOUNTAIN ROAD JURISDICTION. THE CITY OF CA APPLICABLE CODES. THIS PROJECT S BUILDING CODE, SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / Business Name i-. 1 1 1 Business Contact I > Project Address 1*115 (^|lr fojtr/iflbvi/^^'^ C^A^rJi ^'^CA Zip Code , APN# Mailing Address Zip Code , Plan Filet ^ Ft l4ool? Project Contact Telephone # ^ . ^ . - The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): Occupancy Rating: 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD>: If the answer to anv ofthe questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building pennit. FEES ARE REQUIRED. 1. 2. 3. 4. 5. 6. 7. YES • • • • • • • Project Completion Date: / / Expected Date of Occupancy: / / • CalARP Exempt I Date Initials • CalARP Required I Date Initials • CalARP Complete I Date Initials NO^ (for new construction or remodeling projects) H'^ IS your business listed on the reverse side of this fonn? (check all that apply). HyWill your business dispose of Hazardous Substances or Medical Waste in any amount? \M Will your business store or handle Hazardous Substances In quantities equal to or greater than 55 gallons, 500 pounds, y^OO cubic feet, or carcinogens/reproductive toxins in any quantity? [9yWill your business use an existing or install an underground storage tank? HyWill your business store or handle Regulated Substances (CalARP)? I your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your fecility with a total storage capacity equal to or greater than 1,320 gallons? (Califomia's Aboveground Petroleum Storage Act). PART HI: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more infbrmation. YES m X 1. D [H Will the subject facility or construction activities indude operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://wvw.sdapcd.org/info/fact5/pennits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). • f^SWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? ^!p/rardr\ the Califomia School Directory at http://www.cde.ca.qov/re/sd/ for public and private schools or contact the appropriate school district). ^y/(as a survey been performed to determine the presence of Asbestos Containing Materials? 0^ Wrti there be renovation that involves handling of any friable asbestos materials, or disturialng any material that contains non-friable asbestos? H^Will there be demolition involving the removal of a load supporting structural member? 2. • 3. • 4. • 5. • Briefly describe business activities: . ^ . Briefly^describe p^roposed project: i , i 1 r I declar^^dar penaltyj»fpefiic^that to the best of my knowledge and belief the responses made herein are true and correct. Name of ler or Authorized Signature of Owner or Authorized Agent U /Z7 / Date ' FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD A stamp in this box onlv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) Coimty of San Diego - DEH - Hazardous Materials Division LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM THE COUNTY OF SAN DIEGO DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISiON Check all that apply: AUTOMOTIVE • Battery Manufacturing/Recycling • Boat Yard • Car Wash • Dealership Maintenance/Painting • Machine Shop • Painting • Radiator Shop • Rental Yard Equipment O Repair/Preventive Maintenance • Spray Booth • Transportation Services • Wrecking/Recycling CHEMICAL HANDLING • Agricultural supplier/distributor • Chemical Manufacturer • Chemical Supplier/Distributor • Coatings/Adhesive • Compressed Gas Supplier/Distributor • Dry Cleaning • Fiberglass/Resin Application • Gas Station • Industrial Laundry • Laboratory • Laboratory Supplier/Distributor • Oil and Fuel Bulk Supply • Pesticide Operator/Distributor CHEMICAL HANDLING • Photographic Processing • Pool Supplies/Maintenance • Printing/Blue Printing • Road Coatings • Sw/imming Pool • Toxic Gas Handler • Toxic Gas Manufacturer METAL WORKING • Anodizing • Chemical Milling/Etching • Ftnish-Coating/Painting • Flame Spraying • Foundry • Machine Shop-Drilling/Lathes/Mills • Metal Plating O Metal Prepping/Chemical Coating • Precious Metal Recovery • Sand Blasting/Grinding • Steel Fabricator • Wrought Iron Manufacturing AEROSPACE • Aerospace Industry • Aircraft Maintenance • Aircraft Manufacturing OTHERS AND MISCELLANEOUS • Asphalt Plant • Biotechnology/Research O Chiropractic Office • Co-Generation Plant • Derital Clinic/Office • Dialysis Center • Emergency Generator • FnDzen Food Processing Facility • Hazardous Waste Hauler • Hospital/Convalescent Home • Laboratory/Biological Lab • Medical Clinic/Office • Nitrous Oxide (NOx) Control System • Pharmaceuticals • Public Utility • Refrigeration System • Rock Quarry • Ship Repair/Construction n Telecommunications Cell Site • Veterinary Clinic/Hospital • Wood/Fumiture Manufacturing/Refinlshing ELECTRONICS • Electronic Assembly/Sub-Assembly • Electronic Components Manufacturing • Printed Circuit Board Manufacturing NOTE: THE ABOVE LIST INCLUDES BUSINESSES, WHICH TYPICALLY USE, STORE, HANDLE, AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST, WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS DIVISION (HMD) REVIEW OF BUSINESS PLANS. FOR MORE INFORMATION CALL (858) 505-6880. LIST OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses, which include any of the following operations or equipment, will require clearance from the Air Pollution Control District. CHEMICAL COMBUSTION ROCK AND MINERAL 47 - Organic Gas Sterilizers 34 - Piston Intemal - Combustion Engines 04 - Hot Asphalt Batch Plants 32 - Acid Chemical Milling 13 - Boilers & Heaters (1 million BTU/hr or larger) 05 - Rock Drills 33 - Can & Coil Manufacturing 14 - Incinerators & Crematories 06 - Saeening Operations 44 - Evaporators, Dryers & Stills Processing 15-Bum Out Ovens 07 - Sand Rock & Aggregate Plants Organic Materials 16-Core Ovens 08 - Concrete Batch, CTB, Concrete Mixers, Mixers 24 - Dry Chemical Mixing & Detergent Spray 20 - Gas Turbines, and Turbine Test Cells & Stands & Silos Towers 48 - Landfill and/or Digester Gas Flares 10 - Brick Manufacturing 35 - Bulk Dry Chemicals Storage 55 - Chrome Electroplating Tanks ELECTRONICS OTHER 29 - Automated Soldering 01 - Abrasive Blasting Equipment COATINGS & ORGANIC SOLVENTS 42 - Electronic Component Mfg 03 - Asphalt Roofing Kettles & Tankers 27 - Coating & Painting 46 - Reverse Osmosis Membrane Mfg 37 - Plasma Arc & Ceramic Deposition Spray FOOD 51 - Aqueous Waste Neutralization Booths 12 - Fish Canneries 11 - Tire Buffers 38 - Paint, Stain & Ink Mfg 12 - Smoke Houses 17 - Brake Debonders 27 - Printing 50 - Coffee Roasters 23 - Bulk Grain & Dry Chemical Transfer & Storage 27 - Polyester Resin/Fiberglass Operations 35 - Bulk Flour & Powered Sugar Storage 45 - Rubber Mixers 35 - Bulk Flour & Powered Sugar Storage 21 - Waste Disposal & Reclamation Units METALS SOLVENT USE 36 - Grinding Booths & Rooms 18 - Metal Melting Devices 28 - Vapor & Cold Degreasing 40 - Asphalt Pavement Heaters 19 - Oil Quenching & Salt Baths 30 - Solvent & Extract Driers 43 - Ceramic Slip Casting 32 - Hot Dip Galvanizing 31 - Dry Cleaning 41 - Periite Processing 39 - Precious Metals Refining 40 - Cooling Towers - Registration Only 39 - Precious Metals Refining 91 - Fumigation Operations ORGANIC COMPOUND MARKETING 56 - WWTP (1 million gal/day or larger) & Pump (GASOLINE. ETC) Station 25 - Gasoline & Alcohol Bulk Plants & Terminals 25 - Intermediate Refuelers 26 - Gasoline & Alcohol Fuel Dispensing NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (858) 586-2600. HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division INDUSTRIAL WASTEWATER DISCHARGE PERMIT SCREENING SURVEY Date -^.^g'/^ ^it^ I I II/- Business Name TC f^orav^ C^Y^b^tif i-LQ street Address Email Address fi^j . Cl7bLi7i^(i.\Ai P Avm .jll . Covn PLEASE CHECK HERE IF YOUR BUSINESS IS EXEIVIPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility: Acid Cleaning Assembly Automotive Repair Battery Manufacturing Biofuel Manufacturing Biotech Laboratory Bulk Chemical Storage Car Wash Chemical Manufacturing Chemical Purification Dry Cleaning Electrical Component Manufacturing Fertilizer Manufacturing Film / X-ray Processing Food Processing Glass Manufacturing Industrial Laundry Ink Manufacturing Laboratory Machining/Milling Manufacturing Membrane Manufacturing (i.e. water filter membranes) Metal Casting / Forming Metal Fabrication Metal Finishing Electroplating Electroless plating Anodizing Coating (i.e. phosphating) Chemical Etching / Milling Printed Circuit Board Manufacturing Metal Powders Forming Nutritional Supplement/ Vitamin Manufacturing Painting / Finishing Paint Manufacturing Personal Care Products Manufacturing Pesticide Manufacturing / Packaging Pharmaceutical Manufacturing (including precursors) Porcelain Enameling Power Generation Print Shop Research and Development Rubber Manufacturing Semiconductor Manufacturing Soap / Detergent Manufacturing Waste Treatment/Storage SIC Code(s) (if known): Brief description of business activities (Production / Manufacturing Operations):. Description of operations generating wastewater (discharged to sewer, hauled or evaporated): Estimated volume of industrial wastewater to be discharged (gal / day): List hazardous wastes generated (type / volume): Date operation began/or will begin at this location: Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority? Yes No If yes, when: Site Contact, ^fi^ C^^^m- Signature_ ENCINA WASTE _Titie ^TUt/rA y\7f^Mc^l^ Phone No. ,TER AUTHORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760)438-3941 FAX: (760)476-9852 PLUMBING, Development Services ELECTRICAL, Building Division ^ CITY OF MECHANICAL 1635 Faraday Avenue 760-602-2719 CARLSBAD WORKSHEET B-18 www.carlsbadca.gov Building@carlsbadca.gov Project Address: Permit No.: Information provided below refers to work being done on the above mentioned permit onfy. This form must be completed and returned to the Building Division before the permit can be issued. Bullding Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains ^ New building sewer line? Ves No I Number of new roof drains? Install/alter water line? ^/ /^^ Number of new water heaters? ^ Number of new, relocated or replaced gas outlets? / \ Number of new hose bibs? Residential Pennits: New/expanded service: Number of new amps: Minor Remodel onfy: Ves No Commercial/industrial: Tenant Improvement: Number of existing amps involved in this project: Number of new amps involved in this proiect: \^Q0& New Construction: Amps per Panel: Single Phase Number of new amperes Three Phase Number of new amperes Three Phase 480 Number of new amperes Number of new furnaces, A/C, or heat pumps? ^ New or relocated duct worb? Ves No Number of new fireplaces? Number of new exhaust fans? ^ Relocate/install vent? ^ Number of new exhaust hoods? Number of new boilers or compressors? Number of HP B-18 Pagelofi Rev.03/09 UJ7 ' ' (^\^^^ ^ cj^^i^oi^l uj^^ expired le^v^r^u^i^ ' Final Inspection required by: V '5/l IH £u>^t?^ h<^^ a Plan • CM&I • Flre • SW QlSSUED •cv. Approved By BUILOING PLANNING ENGINEERING 7/3--//^ FIRE Expedite? (T) N Old DIGfTAL FILES Required? Y N HazMat (Jl>-?ll^ APCD Health Forms/Fees HazHealthAPCD School Stormwater Special Inspection CFD: Y LandUse: Due? By Density: ImpArea: FY: Comments Date Building 5/7//^ Planning Engineering Fire g/fa/'4 Need? . • Done 4^! Done a Done • Done