1919 Estrella De Mar Ct; ; CBC2018-0261; Permit
{city of Carlsbad Print Date: 08/06/2018 Job Address: Perm it Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 1919 Estrella De Mar Ct BLDG-Commercial 2151700223 $9,000.00 Commercial Permit Work Class: Cogen Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: CASITAS DE LA COSTA: 406 SF SOLAR POOL HEATING SYSTEM FOR SOUTH POOL Applicant: Owner: Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Contractor: Permit No: CBC2018-0261 Closed -Finaled 05/15/2018 06/13/2018 TFraz 8/6/2018 9:13:48AM SOLAR TECH INTERNATIONAL INC PETER RUTIKAY CASITAS DE LA COSTA HOMEOWNERS CORP SOLAR TECH INTERNATIONAL INC 9410 Bond Ave El Cajon, CA 92021-2875 619-743-9193 BUILDING PERMIT FEE ($200D+) BUILDING PLAN CHECK FEE (BLDG) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-COMMERCIAL Total Fees: $183.87 2146 Encinitas Blvd, 102 Encinitas, CA 92024-4371 760-635-1405 Total Payments To Date: $183.87 2514 Jamacha Rd El Cajon, CA 92019-4363 619-743-9193 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $1D6.09 $74.26 $1.00 $2.52 D D D D D D {city of Plan Check No.(Yl.C.;l.018" -0~/n I Est Value 9000 Carlsbad Plan Ck. Deposit Date t; / JLl fl 5( JOB ADDRESS 1919 ESTRELLA DE MAR CT SUITE.t/SPACE#/UNrT# 1"'215 170 02 uu --- CT/PROJECT# I LOT# t PHASE# I # OF UNITS I# BEDROOMS # BATHROOMS I TENANT BUSINESS NAME ICONSTR. TYPE I ()CC GROUP DESCRIPTION OF WORK: Include Square Feet of AWecl.ed Area(•) TO INSTALL A INSTALL 406 SQ FT SOLAR POOL HEATING SYSTEM ON ROOF OF BUILDING ADJACE '"1 1U I Hcc>UUI n r'UULKI vf\ul lr-.v UC LK \_;U;jlA \_;UI\JJ~ ... I\JIU,v, EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE TAIR CONDITIONING I FIRE SPRINKLERS YESQ N<Q YEsONoD vEsONoO APPLICANT NAME Peter H uttkay PROPERTY OWNER NAME 1919 Estrella De Mar Ct Prtnan contact ADDRESS 9410 Bond Ave ADDRESS 1901 Alga Rd CITY t:1 GaJon STATE \_;A ZIP <J;:>U;:>l CITY Garisoaa STATE GA ZIP </;:"UU</ PHONE tlotl-;:>UU-bb 1 8 I FAX PHONE bl !:i-tltltl-01 /1 IFAX EMAIL peter (.g) sdsol arperm its. com EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS. NAME ::;01ar I ecn energy ::;ysrems ADDRESS ADDRESS 941 o Bond Ave CITY STATE ZIP CITY cl GaJon STATE GA ZIP <J;:>U;:'l PHONE !FAX PHONE tlotl-344-o::iu 1 YAX EMAIL EMAIL Jt(.g)solartechonl1ne.com I STATE LIC # STATE UC# tlbo0;:"l l'LASC-4b !"1Ysus "~~;;1<1;:-0 (Sec. 7031.5 Business and P_rofess1ons Code Any City or Co_unty which requires a permit to construct. alter. improve, demolish or repair any structure. prior to its issuance, also requires the applicant for such permit to file a signed statement that he 1s licensed pursuant to the prov1s1ons of the Contractor's License Law {Chapter 9, commending with Section 7000 of D1v1s1on 3 of the B_usmess and Professions Code} or that he is exemP.t there.from. and the basis for the alleged exemption. Any v1olat1on of Section 7031.5 by any applicant for a permit subJects the applicant to a c1v1I penalty of not more than five hundred dollars {$500}) WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjur;one of the following declarations D I have and will maintain a certificate of consent to self-insure for WO<kers' compensation as provided by Section 3700 of the Labor Code, for the perbrmance of 1he work for which this permit 1s issued ~ I have and will maintain workers' com_pensa1ion'vas ~ired by_ Section 3700 of the Labor Code, for the performance of the work for which lh1~ ~rm1t is issued. My WO<kers' compensation insurooce canier and pohcy ~ eo t:ien(;nma, K insurance L,Ompany Pol vvc;1v1L,r't:ll\Ju;:>l:l<1u1 _ 0 0111,::u I ti num....,r are· Insurance . icy No. Exp1rat10n ate---------- ~ secbon need not be completed 1f the permit is for one hundred OOllars ($100) or less LJ Certificate of Exemption: I certify that in the performance of the oork for which this permit is issued, I shall not employ any person 1n any manner so as lo become subject to the Workers' Compensation Laws of CaHomia WARNING: Fallure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in :i;~:;:::::::~:::lon, damages a~ , interefl and attorney's fee~ AGENT DATE 6 Pf I? OWNER-BUILDER DECLARATION I hereby affirm that I am exempt m)(1J Contractor's License Law for the following reason. D D D I, as owner of the property or my empbyees wrth wages as their sole compensation, will 00 the work and 1he structure is not intended or offered for sale (Sec 7044, Business and Professions Code· The Contractor's License law ooes not apply to an owner of property who builds or improves thereon, and 'Mlo cbes such wo!k himself or through his o'Ml empbyees, prov1d3d that such improvements are not intended or offered for sale. If, ho'o\ever, the building or improvement is sold within one year of completion, the owner-builder will have !he burden of proving !hat he did not build or improve for the purpose of sale) I, as owner of the property, am exclusively contracting with licemed controctors to construct the proJeC1 (Sec. 7044, Business and Professions Code· The Contra:tor's License law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contracto~s) licensed pursuant to the Contractor's License Law) I am exempt under Section ________ Business and Professions Code for this reason 1. I personalty pl011 to provide the major labor and matenals for construction of the prop:ised property improvement 0Yes 0No 2. I {have I have not) signed an applicat10n for a building permit for the proposed work 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contra:tors· license number) 4. I plan to provide portions of the work, but I have hired the folk:>wing person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number) 5 I will provide some of the work, but I have contra;ted (hired) the following persons to provide the work indicated (include name I address I phone I type of WO<k) AS PROPERTY OWNER SIGNATURE QAGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required kl submit a business plan, ocutety hazardous materials registration form or risk management and pr~ntion progam under Sections 25505, 25533 or 25534 of the Presley-Tanner HazarOOus Substance Account Act? D Yes O No Is the applicant or future building occupant required to obtain a permrt from the air pollution control district or air qua~ty management district? D Yes O No Is the focili!y to be constructed wittiin 1,000 feet of the outer boundary of a school site? D Yes O No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. lcetlly .... l hmo ieacllleapplicalonand-dlattlleaoowinlmnation~oom,ctand lhattlle.-..ammtlleplans~--1-mconwllllh all a1,-....and--relalil1!m buldllW- 1 hareby >.Jlhooze representauve olthe Cily cf Calsboo to <>1ter upon the-e rrertoredproperty lor inspectrn purposes. I ALSO AGREE TO SAVE. INDEMNIFY M-JD KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUD3MENTS. COSTS AND EXPENSES \'>HIGH MAY IN ANY WAY ACCRLE AG/,JNST SAID CITY IN CONSEQUENCE OF THE GR.ANTING OF THIS PERMIT OSI-IA_ AA OSI-V\ perm~ is required fCf exe&1ations over 5'0 ~ i:lld demciitkxl cr o:>rsructicri cJ s1n.x:!Lres over 3 &ories in hag ht. EXPIRATION: Every pemiit issooj by the Bukilng O!icial urm the l)"ovis()flS of this Ci:xie shall e)q.)lfe by imila:bn ard oorone null ard void if the tll!k:ling or WOO< authaize::l by sudl permit is net commfflced wrth!n 100 <Eys from the date ct such J')c!rmit or if the bulkmg cr v.ork autoorized su:ti permit is ~cied or al::an:bloo ct any tirte ctter the 00/k is o:mrrerced for a perm of 100 ctiys {Sa::ti:Jn 100.4. 4 Unifam Buik:Jng Cede) ~APPLICANT"SSIGNATURE DATE ,1,7/~,it'f 1 , '" ~'1 ' ~. ·,r Jd >; ; ' , ~' '1 , , ' , v ' , ' ', 'p,' >'':':"' :4''' PERMIT INSPECTION HISTORY ~EPdRT (CBC20184l261) Permit Typo: BLDG-Commercial Application Date: 0511512018 Owner: CASITAS DE LA COSTA HOMEOWNERS CORP Work C\a~s: Cogen Issue Date: 0611312018 Subdivision: LA COSTA CONDOMINIUM# 1 UNIT# 2 Status: Closed -Finaled Expiration Date: 0210412019 Address: 1919 Estrella De Mar Ct Carlsbad, CA 92009-6128 IVR Number: 11359 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete -·-·---------·-·· -·--·-· 0810612018 08/0612018 BLDG-28 Solar 066120-2018 Passed Tim Frazee Complete Water Heater Checklist lten1 COMMENTS Passed BLOG-Building Deficiency Pool solar system OK Yes BLDG-Final 066119-2018 Passed Tim Frazee Complete Inspection Checklist Item COMMENTS Passed BLDG-Plumbing Final Yes BLDG-Electrical Final Yes ----·----·---··------------·,~ .. August 06, 2018 Page 1 of 1 ~ Es Gil A SAfEbuilt Cornµ;i:1y DATE: 5/28/2018 JURISDICTION: Carlsbad D _)ld"'PUCANT _,,,;21 JURIS. D PLAN REVIEWER D FILE PLAN CHECK NO.: cbc2018-0261 SET: I PROJECT ADDRESS: 1919 Estrella De Mar Ct. PROJECT NAME: Casitas De La Costa HOA Solar Pool Heating system D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: _ -J) Telephone#: Date contacted: _ (b~ ) Email: Fax #: Mail Telephone Fax In Person D REMARKS: By: Morteza Behesbti EsGil Corporation 0 GA O EJ O MB O PC Enclosures: 5/17 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad cbc2018-0261 5/28/2018 [DO NOT PAY -THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK#.: cbc2018-0261 PREPARED BY: Morteza Beheshti DATE: 5/28/2018 BUILDING ADDRESS: 1919 Estrella De Mar Ct. BUILDING OCCUPANCY: BUILDING AREA Valuation PORTION (Sq.Ft.) Multiplier Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance -------, 1997 UBC Buildin Permit Fee ... g .~I ------, -~997 UBC Plan Ch~~~ Fe~ _ _ __ -~i Type of Review: Complete Review D Repetitive Fee ~ Repeats Comments: D Other D Hourly EsGil Fee Reg. VALUE Mod. D Structural Only ($) 9,000 9,000 $60.26/ Sheet of SCOPE OF WORK DEH2018-FAMD-005191 TO INSTALL A INSTALL 406 SQ FT SOLAR POOL HEATING SYSTEM ON ROOF OF BU ILDING ADJACENT TO THE SOUTH POOL AT CASITAS DE LA COSTA CONDOMINIUM SYSTEM INCLUDES A BYPASS VALVE, SOLAR CONTROLLER, AND BOOSTER PUMP LOCATED AT 1919 ESTRELLA DE MAR CT, CARLSBAD CA 92009, APN: 215-170-02 -------------- €stre11a Det 11 .. '"1ar Court --, l~ ' ' ' .... Aviara Pl<wy _ ~ ·--~ '" ,1. !:!). n ~ 3 5· 0 ,0 I /0 + ~ i Alga Rd Alga Rd fn~"•d~ •• + - ' ' " . ..,,,,() ~ \ \ \ CG (.) Ul \ \ \ QI " I .. ........ ........ r -........ --' Property Line/ .. CWN I Y Of $AN UtEGO DEPARTMENT OF ENVIRONMEHTAL HEALTH PLAN REVIEW ........ ........ ........ ........ ........ ........ I.. ~ Q) a ~ ~ -V) UJ '""' C't E :, Ill 1' ~ 41 a:: Q 8+- 1919 e'ltNM<I do Mlor Ct.C..tlabH,CAll200II " Vicinity Map C lty of Carlsbad Bu Ud ing Division Jtr·.J 1 3 2018 APPRO\l[D E. r: fn B (~) ISSUEC :Y: -~'--'-"W'-'-____ _ ... ,J<•'\1,6 r,,~tt-~ \•'' '>.. <;. -Alga Rd K - -• ·•/> <;.,... ~ .. <;. ~- PlANSACCEPTe·8·R--BJECTTOTHE REOUlREMENTS Of THE STATE ANO LOCAL REGULATIONS. THIS STAMP tS NO ASSURANCE ™AT TiiE A.ANS OR SPEC~ FICATtONS ARE CORRECT lN EVERY RESPECT ERRORS fN Existing Commercial Building OEStGN OR CONSTRUCTION MUST BE CORRECTED. .. · .. (R---sz:il1'a ~D FOAfll.A.-.s s.tuir R!kAiN OH TM! JOa IITI OURmG CONSTIIUCT10N ce,c.2. ol I ~ I () UJ ~ D:: ct -I co .nO • "1" • E,A • 0 $v, ..- • (I) • N >, ('() W) e.. LO >, N CO O> 0 co '-N :it Q) Q) O> ('() . C > CJ) U ._W<(<(..-:.::J o.c-oOo,> '- -U C ·('() 0 C.> Q) 0 C -.:;t t5 f 1-en .Q,r---ro -!;:. 0 (U ...--.!:; C~ 00> C 0 0 ..... ..-0 -.:t-co () (f) O> w ........ o CD >--st ~\ .· i o_ ~ ~ N ~ ID ~ Q.) t:: co L. Q) co a. .!l 'It (/) 0 . C: a: ,!,! (11 ...J a:: Cl C <{ :§ 0 0 ::J I co ca ro 0) ro ._ iii 0 ~0 ·-e1> 0 o 0~ c:Oa..Q>NQ> ~ ca.com E 0...J5ca<1'.E Q)O Q>Oo ~Cl (J) .!:: -o·O C1> (/) (/) in cu Cl Q.~ ~ .0.£ ·-·-0) (/) -0 (/) (/) .-1: .!!? ... cacu a,cax 0..0 0 .-0W Drafted By: San Diego Solar Permits www.wndttgotOillJpPtrr1lls. "' 4203 Gtl""'W-. A._., Sui• 1C SanOWgo. CA 92117 't,'19:C 189-fl997 T-01 u EQUIPMENT SUMMARY SUNSTAR filn.- IR INTELLIFLO® VSF VARIABLE SPEED AND FLOW PUMP -BOOSTE BYPASS AND AUTO CONTR CUSTOMER PERF AIN COVERS: AQUASTAR 10AVR101 10 INCH ANTI-ENTRAPMENT COVER @4.8 FPS POOL VOLUME -12,700 GALLONS EXISTING DRAIN COVERS: AAQUASTAR A8R102 8" SUPER HIGH FLOW ANTI-ENTRAPMENT COVER EXISTING FILTER PUMP: PENTAIR INTELLIFLO VARIABLE SPEED PUMP COLLECTORS ATTACHED WITH QUICKMOUNT PV EAGLECLAW MOUNTS AND FLASHINGS ALL APPLICABLE LOCAL BUILDING DEPARTMENT PERMITS AND FINAL APPROVAL SIGNATURES WILL BE OBTAINED PRIOR TO PLAN CHECK FIELD INSPECTION. LEGENO -----HOTWAn:R i5f2J V/llJJUIA RfUlf VALVE --COID WATER ---WIIE/CONOUIT -&-CW/# ON FLOW MfTIR _£_ ACIUA11NG ISOIATION VALVE --tx5:J--IAU VAL VE --Jh-IH-!JNE FLOW SENSOt! -f'--J--o«1: VALVE -t--ACTIJATlNG J.WAY VALVE 1. 5UNS!AISTUOC0lllCTOl{10TOTAl,SltCNO. IOOOIB88) 8. IXISTN;POOLfLTEl(S) 2 IAU VALVE {N.O.) 9. El0$TN)CONVINT10NAI. POOL HEATEl(S) 3. OAMJ'.QN FIOW METIi 10. SOW t.T!ICONNICOON N)IN! -4. ACII.IATING 'J.WAY VALVE (NON-IOSITM 3fAI) 11. NeN SOW IIOOS19 l'\.WI (3.0 HP l'fNTAll llfflUIRD) 5. VACWl,\ lftlf VALVE {INSTAU. {1) ON UP\Y lH Al EAVE OF IOOfJ 12. NEW SOW POOL HEATHG CONTIOUBI 6. IMMEISION-TYPf TEWIIATUIE SENSOI 13. OtEOC VALVE 7, EXJmlG RLTEI l'\.WI {l'fNTAII IHIRlltO) NOT& THIS DIAGIMI IS-TO $HOW HOW 1IIE SOlAI l'OOl HEATHG SYm/,1 m MO TltE EXISTING POOL SYSWtl. NOT AU. CQI\Pa,ftNTS Alf SHOWN. SE£ OOSTING l'OOl PlANS FOt FIJfrn!l ll*<lR>MllON IEGAR!lt«; 11tE POOL 1H QU:S1IOk ADltEIII: TO All LA11:S1 PUJMIW, MEOiANICAI, ANO l'OOl COllES. I I I I N011:o ElfCIIICAUY 1Nm1ocux1S11NG mm PUMP WITH I NEW SOW IIOOSTll l'I.WI, SOLAI SUPPlY PUIIP , ! 1 SW.U. IE INSTAUED SO THAT IT CAN ONlY 111.N WHEN _J * THE EXIS!tlG PUMP IS ll\ffilNG. r::--i ~-11 , I ' I _ _J 'I 1---------------~. I MAIN RLTBI POOL.RUB I @ PUMP A I l ,., K 911---< >---;-I 1"-f-------{:)/c:'.}.---L 9 ~1--, I I - ~OEMICAL RIOl,IM>JN OWN FIOM SIOMMII I I I TOPOOI Turnover rate will not be reduced below minimum required amount due to solar system installation nor will it have pipe velocity exceeding 6 feet per second in any suction piping or 8 feet per second in any portion of the return system. ~ Robert B Wheat, C-46 #865321 f!l!I) N)IN! ~ I~ Pool (E) Stairs t::: :t () LJ.J l-o: c( .., (0 41)0 . ,. • ~IA • ~ ... v, ..- • (I) • N >, ('f) ~ e .p. LO >. N <O Ol O ex:> '-N =l:t: Q) Q) O'> ('f) . C> ,...._u ~LU<(<(~:::J o.c-oOq '- -U C -('f) 0 UQ)QC....ro ~I-en .Q..r-,;.. ro -~ 0 (\'J -.!::; C: ~ ..--(.) O'> C oo"-t"-«io 0 (J) O'> LU ._(.) >,. <D ,~ -st t'O ' Q) 0 .c . :':: ;:;i Ill (") t: ~ Q) co ..c 'II: 0 . ct: " ('El a. ::::; O> C: <( ~ 0 ..; ·3 I O CD ro ro m co ~ ti 0 ~o ·0 cuoo o .... c:Oa..Q)NQ) ;::ro.comE Q.....l"5.!!!<( E a,0 a:;Oo ~o Cl) !::. -c-o ... (/) (/) w(/) ro e> "" <ti <ti .0 C: C..-t::~a, (/)~ 0 (/) (/) .:: (/) ~ <ti <tlo, ro ·x a.oo..-ow Drafted By: ~ S.m Diego Solar Permits o4·,,,., ~ ~dieg,""SOJ«pem,,h (.Offl 4, .~·"W:~A-,Suit~ 103 CA 92111 -97 PV-01 . .. -.l ~ ... -."!-._ . ~ , _v TECHNICAL INFO RMATIO N AND SPECIFI .,-.:,. : ~1·;;> i•suNSTAR • SOLAR POOL HEATING Technology of tomorrow available today. Innovative design, rugged construction and reliable operation make SunStar the perfect choice for your swimming pool heating needs. ADVANCED DESIGN "Individual tube design" allows wind load to be virtually eliminated, hence no straps across the collectors. The individual tubes also prevents moisture from being trapped under the collector. Cracks and leaks due to thermal expansion and contraction are eliminated since each tube is able to expand and contract independently. SINGLE PIECE CONSTRUCTION Headers and risers are molded together forming one solid piece. There are no seams or welds between the header and risers that can crack with age and stress. SQUARE HEADER The SunStar collector's unique square header cre- ates added hydraulic turbulence. This unique header shape maximizes flow charac- teristics and increases efficiency. ONLY FOUR ROOF PENETRATIONS Years of research and testing have led to an inte- grated panel mounting system that in most cases requires only four roof penetrations per collector. ~wtl SUNSTAR ~~ SOLAR POOL HEATING Double Your Swim Season / / / /· / / \. / / /~ / / / . / / / / / / ~ MOUNTING SunStar has eliminated the need for hoses and hose clamps. This makes a SunStar installation aesthetically pleasin g, sleek and strong. WARRANTY Limited Lifetime warranty is non-prorated for the first twelve years and includes freeze protection. This warranty is simply the best in the industry. No other solar collector manufacturer offers this kind of protection and peace of mind. Using the power of the sun to heat your pool A. Using your existing pool pump, pool water is directed through a series of valves to your solar collectors. L Pool water enters the solar collectors at the bottom and rises to the top through the individual tubes of the collector. C. As the water rises through the collector it is heated by the sun's radio nt energy D. The water is then returned to the pool to repeat the cycle until your pool has been warmed by the sun. C D • •• ~ ,ii SPECIFICATIONS & TECHNICAL INFORMATION UNIQUE TECHNICAL FEATURES: CERTIFICATION DATA • The individual tube design allo NS for expansion and contraction eliminating cracks and leaks. • One piece 'overmolded' const ·uction elim inates welds. • No moisture build-up under co llectors to cause roof deterioration. • Integrally pigmented for efficie • Design certified to withstand h straps across the collectors. • Low collector head loss rate re icy and appearance. ,rricane win d load, yet no need for foces pump requirements. BTUs PER DAY Certifying Organization lnt'I Standard ORTECH Equivalent of 948 BTU/sq ft National Standard SRCC Equivalent of 948 BTU/sq ft Florida Standard SUNSTAR STR-40 STR-40 38,550 38.550 956 BTU's/ft Collector Rating Number Thousands of BTU 's per day per panel Solar lnsolation Category T("F) 2,000 BTU/ft2 1,500 BTU/ft2 l ,000 BTU/ft2 A (-9) 82.16 64.96 Water Temp. B (+9) 53.37 36.62 Minus Air C (+36) 19.04 6.36 Temp D (+90) 0 0 E (+ 144) 0 0 HEAD LOSS PER FLOW RATE i ~ ~ ...J 0.600 ~~-----,------~ ... ~ ~~? <::, <::, .--- I C ~ 0200 1 --+-r-- 1 :i: 0.000 ~-!lll-11!'1111 _____ .__ 2 6 7 3 4 FLOW RATE GPM l 1~SUNSTAR 'V4" SOLAR POOL HEATING 47.83 19.94 0 0 0 STR-50 p, 'erformance Equations 46,1 50 .872 -3.729 (Ti-TA) I I Kl = 1.00-.041 (S) 46,1 50 .87 -3.735 (Ti-TA) I I = l.00-.0316(S) .. 0104(S)2 KAX = .828 -3.26 (Ti-TA) I I Kl= 1.00 -.l l(S) SU NSTAR STR-50 Rating Number Collector Thousands of BT U's per day per panel Solar lnsolation Category T(°F) 0 BTU/ft2 2,000 l ,500 BTU/ft2 1,000 BTU/ft2 A(-9) 9 18.74 78.07 57.49 Water Temp. B (+9) 6 ,4.13 44.01 23.96 Minus Air C (+36) 2 '2.91 7.64 0 Temp D (+90) 0 0 0 E (+ 144) 0 0 0 COLLECTOR DAi A. Collector Model STR-4Q ., STR-50 Size, Nominal 4' X 10.5' 4' X 12.5' Width 49" 49" Length 127• 151.5" Area (sq. ft) 40.7 48.7 Manifold Diameter 2· 2· Weight (dry) 19 lbs 22 lbs Volume Capacity 3.3gal 3.7 gal Working Pressure 90psi 90psi Burst Pressure 270 psi 270 psi Recommended Flow 4 gpm 5 gpm I (.) UJ ..... a:: c( _, co wO e ~ E O , a>(/) • --..-~ Cl) e N >. C") (f) • .f.... L.() >. N CO 0) 0 CX) '-N ::t:t: Q) Q) (J) ('I) . C> (J)U ._W<(<(..-~ o..c,:,Oq '- -U C -('I) 0 UQ)QC"¢U f I-CD .Q.,I'-CO -'-o<U -.b c:co..-omc 00,;t--coO 0 W m w --0 >, (0 en -'<I' !~ "' ' Ql () ~ ~ co C') -tO ~ (0 Ql CX) .D 'II: 0 . ('ll a:: .!.! a:: ...J C) C: <( :Q 0 ..... ::, I 0 CD .... ~_mmro ... (/) o~0 ·u Q>Oo o._ c:Oa..(l)N(l) ~m..c:OO>E O--':i ~<C E (l)O °QiOo ~0(1) ~.;O (/) (/) (/) (1J C) G>n,n,W..oc: C.:!= :!=a>~~ 0 (/) 11).,.... '-·-'-<1J<1J a,<1J >< a..oo ..-ow Drafted By: ~ an Diego Solar Permits ~J"1w . ..=td~.g .. ~solarpt'rmi11.com 4lc·~ '""""s.. Aw, (j,u1i.-101 !.Y1i ~~~.CA92ll7 "-'~ ••9-3997 PV-02 Eagl~~laW ............ MUUN !'ING SYSTEM Eagle Claw Flashed Mounts From Quick Mount PV Protect your solar investment with the industry standard in waterproof roof mounts. Developed by Quick Mount PV, the solar industry's leader in code complian t waterproof mounting systems, in partnership with Aquatherm Industries. WHY EAGLE CLAW FLASHED MOUNTS 0 Superior Waterproofing & Strength • Patented Elevated Water Seal technology • Meets or exceeds all roofing codes, standards and best practices • Engineered to withstand extreme wind and rain & Quality That Lasts Manufactured and engineered to last the life of the solar array. • A ll aluminum 9" x 12" flashing • Sta in less steel hardware • No maintenance required • 12 year warranty 6 Made In The USA ~uick Mount PV· RE&PECT THE ROOF Eagle Claw Flashed Mounts I QMECM Elevated Water Seal Technology® THIS EDGE TOWARDS ROOF RIDGE ITEM. NO. 1 2 3 4 5 6 12.00 1.75 3.00 I r-,J I. ;==4.50=:j ---9.00 · 1.00F . 12 t - - DESCRIPTION QTY. FLASHING, 9" X 12'' X .0.0", .l005. BWNZE ANODIZED I QBLOCK. POOL. UNIVERSAL BASE. PLASTIC. BLACK 1 QBLOCK, POOL UNIVERSAL CAP. l", 6061-T6. BRONZE 1 RUBBER GASKET, l/16'Xl/4"xl"xl /8" ID, EPDM 2 WASHER, SEALING, l /4" ID X 3/4" OD, EPDM BONDED SS 2 LAG SCREW. GRK RSS WASHER HEAD. 1/4"X 2· 1/2", T-25, PHEINOX SS 2 6 Quick Mount PY TllLE: QMECM: QMPV EAGLE CLAW FLASHED MOUNT FLASHING AVAILABLE IN MILL AND BRONZE ANODIZED FINISHES l>llf~OllfER\IIIISEsPEClfS>: SIZE D~AWH SY: DFM REV ___ c_M,_111 :'~.ffl.W~'::!i.~~~~".s:'r~TIIMVIT""•J,IY•"'~'CIH"''•s09•' HEADER BRACKET (NOT INCLUDED) STRAP (NOT INCLUDED) HEADER BRACKET (NOT INCLUDED) OtME"ISIOl"fi~PftlN::HES 10..f.ltANCe;: fllACTIOtW.t IJI TWO f'L,1,CE DfOMAL 1.11 11-0tf:Ef'V,Cf0fa.1AL t,12$ ----- A O..TE: 11 /25/201' 1 SCAH: 1:3 ""'9GHT:0.'3 ~~efl l on \ I ~ --__ ,_,,.,...l Bl 7.2.3-25 NOTE: Quick Mount PY Flc: QMECM: QMPV EAGLE CLAW FLASHED MOUNT 1) RECTANGLE GASKETS ONLY USED WITH HEADER BRACKETS AND POOL CAPS .,,mo,,""'"''c•,,o 2) ABOVE ARE REPRESENTATIONS OF POSSBILE WASHER AND GASKET ORIENTATIONS ,'<·~:;~'." .,..,,... ~IZf Di!I\WN !!Y: DIV. t R(V -·--~-·--· T"ll'~n:;)H(O'l••"'tDt1MJ~~-Mn.l!,..,.....Of0..:::{"'1QU<J"'Y 4'lfl' .... ~tQll'i""-"IOIIAl •.....:::U~..,.,,,..,'lli,i__,..~,c:u,:,MQI.Hl',V"~ 19,l.'.."lK)l>,l;,.ll 14 CO,_OTiCAUOtlo"W'll,IG l'h:)l">CJ:C(C"-' ... ~ I, I 'W'HPI.Jl<:.!OEC"'•' t n A .JATt: t11:~no1: -· 1 \C°"o.l l:3 -~.,.;C,6.3 ,S>i<fl,.•::f'i: Jan-2017, Rev 2 I () LLJ ~ D: <t ..I (0 il)o • ,. ~ E,A • 0 $v1 r- • Cl) e N >, Cf) CJ) " I.() >-•N co CJ) 0 (X) ,._ N :it Q) Q) 0) Cf) . C > ""' (.) w <( <( ...,, ·-... r-_J 0 .c "O O o;> ,._ -(.) C -('f) 0 (.)Q)QC"<:tU ~ t-(D .Q.I'-co -ro a co -.b C:-r-00) C 00"<:t-coo u w m w .._..o >, (0 en --.:I' ('G ' ~~ 0, (.) Cl} • r. . cii S:: N 0. (l'.) C') Cl} t:: ~ ct 0, a) en .0 'Ila 0 . C 0:: 0 ~ a.. ::i O> C <( 32 0 .,..; ::, I 0 CI) $_romrn '-~ o~g ·~ Q)o 0 <1>N<1> c: o..OO>E ~ ctl.C Q-'-=,~< E <l>O Q>Oo >-o Cl) ~ -c-o t:: (/) (/) (/) ctl 0) Q) $ $ w .0 .£: c.._ ·-0) (/) -0 (/)C/l~"'i::::.!!! ... ctl ctl 0) ctl >< o..oo ~ow Drafted By: ~ San Diego Solar Permits rw-::'. :YidMl'qc ,-alarp,Prmir~corn 4;,-::l C..MiH A..,., Suitt> 103 1)~911, CA <f'1l 17 ... -~Cl..899? PV-03 SolarTouch TM Solar Controller System Installation and User's Guide System Status Water 60F. Target Temp 80F 900 Menu .._ More .·~~ ' I ·~ .• Enlilt' ------OPERATION _____ _ Menu: Press to access menu and scroll through options. LeaaJMore: Press arrows to lower or raise target temperature. Move cursor up/down to adjust setting within menus. Enter: Press to select a menu item. Save a setting. Disable and R~Enable SolarTouch ayatem: Press and hold Enter for three seconds. ~(TYl'E3) Conwl-® ==.:=i-'"' C VL • ELECTRICAL RATINGS: E324842 ""'""""'--No.1-'to11AWOcc:inctJckn ..-to< ....... 80'C(1<0'f). INPUT POWER: 120VAC, .4AMP or 240VAC, .2AMP-51WO Hz. CONNECrlO ONE SOURCE ™-Y. SEE AC WIRING DIAGRAM INSIDE ENCLOSURE. OUTl'IITS: LOW VOLTAGE: 24 VAC, .85 AMP ttGH VOLTAGE: ISOLATED ORY CONTACT· MAXIMUM 240 VN:,, 50/80 HZ, 10AMP PER RB.AV CONTACT 0011'\JT. A 'Y Pe:alalr Water -. Ptal 111dSp1" IMPORTANT SAFETY INSTRUCTIONS .PENTAIR SOLAR SYSTEMS AND PARTS CATALOG ~!9o• .... ;~ • --:-:;,;-t:Pt.i..nr,,.:::--_ ... 4 ~~ ............ "'"'"··--...... -...... ""---~ ~... ..... ........ ...... ._ ·-... ~-..... ---· ....... ~ ...... ~ SOLAR SYSTEMS & PART T pentai rpool.com I () w ..... a: C .J CD ,cnQ . ~ E O • Cl)IA e -..... v, ...... •<I) e N >, Cf) W A LO >..,N CD 0) 0 (X) '-N :it Cl) Cl) (j) Cf) . C> ,.._(..) '-W<(<(~:.::i 0 .1:: "O O a;> '- -(..) C -('() 0 (.) CD O C "-t t5 ~ I-CD .Q,r--,;.. ro -~ o ro ......... .t:. S::~...--00'> C oo...r-_©o u (f) (j) w ........ o £ i~ co <O -..,. (ll • Q) (.) .c ~ N co (") t: ~ Q) co .J:J 'lie 0 . Cl:'. 0 a: ::i 0) C <( 32 0 ~ ::, I (.) co <ti «j 0) ni '-iii O c::: 0 ·-'" o ..::::a 0 ...,(.)o<1>NG> s:: o..Oa>E 3: <ti .c 0...J:5~< E <1>0 -0o >, 0 (I) t ,:j (.) t::(/)(1)(/)('CJO) (1) ~ ~ w .0 .E:; C.,_ ·-0) (/) .... 0 (/) (I).,.....::.~ '-<tl<tlo,<tlX Q.00..-(.)W Drafted By: ~ San Diego Solar Permits www.1«tdiego).Ola,permits.com 4203 G.n.s.e Aw, ~uite-10] Sar. o~;o. CA 92111 .611}• }'159-8997 PV-04 -11 Forming a watertight seal, patented PPC panel clamps eliminate rubber hoses and metal clamps that require regular rooftop maintenance and ·replacement, saving time and money. Clamps also allow for closer mow1ting of panels which is more visually appealing and more efficiem. CERTIFICATIONS • Certified NSF Standard 50 by the National Sanitation Foundation, ensuring the safety and performance of its products when used for public pools, spas, and recrealional water facilities. STR-001 &ochl.n&-Canmercial indd 3 • Certified TSO 9001 for quality management and ISO 1-1001 for environmental protection by the International Organization for Standardization. @ The tu1ique square header shape maximizes flow and increases efficiency. Headers and risers are molded together forming one solid piece eliminating seams and welds that can crack with age and stress. This single piece construction produces the strongest possible connection and ensures a low Low liead-loss riser tubes eliminate high head pressures, maximize efficiency, and protect against clogging. Tubes expand and contract independendy, helping to eliminate cracks. The rowtd design captures more heat. • Certified SRCC OG-100 for safety, durability, and performance by the Solar Rating and Certification Corpora lion. ~· 1<Y.l2AMI - UMASOLAR 950 Sunshine Lane Altamonte Springs, FL 32714 www.sunstarsolar.com 1-800-79-SOLAR (76527) I STR-001 Broc:hur..comme,c:il:Undd 4 SUNSTAR. SOLAR POOL HEATING @ STR-001 1404 ©2014 UMA Solar 51511 4 10:32 AM I :t () UJ l- o:: C ..I co '1)0 . "'1" §Cl) C ~ Cl) e N >, Ct') W ..-LO »""N CO 0) 0 co L... N :it (l) (l) 0) Ct') • C > "" (.) w -<-< ...,, ·-~ -...... ...... ..-_J o.c-oOo;> L... -(.) C -Ct') 0 (.)(l)OC-..;tU E 1-m .Q.r---,;.. co -:.. 0 co .-. .!= C:~..-00> C o o'<:t-co o U <f> 0> w -0 >. I~ (ll a.. ~ 0 -I 0 co -"'3' m ' Q) 0 ..c: • s: 1'i co C'l -ll) ~ co Q) a) ..0 'II: 0 . Ct: (.J ::i C> C: :§ :, CD _!g _ ro m ro ~ (/) o~o ·-a, o O oe c:Oa..<l>N<l> := ro.com E O__J:i~~ E <1>oa:;Oo ~o Cl) .!:.-o-o (/)(1)(/)CIJC) C1>roroW.oc:: Q. :<=: :!:: O') (/) :;:; 0 (/) (/) ..... .:.~ ~CllCllo,Cll >< D..00..-0W Drafted By: ~ San Diego Solar Permits WWW-~INJOSOl.-p.rmit!i.Com 4103 Gtrw~Aw, Suii. lOl Mn OM'go, CA 9211 7 6191 289-8997 PV-05