HomeMy WebLinkAbout1921 PALOMAR AIRPORT RD; 200 | 250; PC130022; Permit10-28-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No PCI30022 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 1921 PALOMAR OAKS WY CBAD PLANCK 2120911800 $0 00 Lot# Construction Type NSA & SPEC SUITE - OFF TO OFF // 3,671 SF FOR NSA IN STE 250 //121 SF SPEC SUITE Status Applied Entered By Plan Approved Issued Inspect Area PENDING 03/27/2013 SKS Applicant VICTORIA MELVIN STE 207 3160 CAMINO DEL RIO SOUTH SAN DIEGO CA 92108 619-624-0521 X 14 Owner COGNAC PLAZA LLC C/O PRUDENTIAL REAL ESTATE INVEST 4 EMBARCADERO CTR #2700 SAN FRANCISCO CA 94111 Plan Check Fee $599 44 Additional Fees $0 00 Total Fees $599 44 Total Payments To Date $599 44 Balance Due $0 00 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired -C^l--^^ /( Cy^\^ oYVf. OLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE LANNING NGINEERING UlLDING •HEALTH ] HAZMAT/APCD i <W/ CITY OF , CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@cadsbadca gov www carlsbadca gov ^ t-^ Plan Check No. ^C- | ^ - Z 2- Est. Value ( 0(p^ 75^^ Plan Ck. Deposit Datejr/i? it ^ SWPPP JOBADDRESS' 9 SUITE#/SPAOE#/UNIT# APN >^ 0-1/ M^l'n-pt. CT/PR0JECT# LOT# PHASE # tt OF UNITS tt BEDROOMS # BATHROOM^>. TENANT BUSINESSKAljJE CONSTR TYPE OCC GROUP DESCRIPTION OF WORK Include Square Feet of Affected Areafs) uA"rttiN^fii uviK> T:!' 3(^11 (^z^o) / / 2-( <: EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRESMNKLERS YESQ* NoQ YES^NOQ YEg^NoQ APPLICANT NAME (Primary Contact) APPUCANT NAME (Secondary Contact) ADDRESS ADDRESS Cny STATE ZIP CITY STATE ZIP PHONE ^ FAX PHONE FAX EMAir .« 1 EMAIL PROPERTY OWNER NAME ' ' CONTRACTOR BUS NAME \ f 1 r ADDRESS ADDRESS , ' . -t' ft 1 CITY_ STATE ZIP CITY^ STATE ZIP PHONE _ FAX PHONE ^ EMAIL EMAIL 1 ' ,1 ARCH/DESIGNER NAME & ADDRESS STATE LIC # STATELIOfe •• CLASS CITY BUS LIC # (Sec 70315 Business and Professions Code Any City or County viihich requires a permit to construct, alter improve demolish or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he -' ' " ........ . . - - — ... . ^ . r, „ Business and Professions Code) or tnat he is exempt therel civil penalty of not more than five hundred dollars ($500)) applicant for such permit to file a signed statement that he is licensed pursuant to the provisions ofthe Contractor s License Law (Chapter 9 commending with Section 7000 of Division 3 ofthe Business and Professions Code) or tnat he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a Workers' Compensation Declaration / terehy affirm under penaity of perjury one of the following declarations i7H I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued have and will maintain workers' compensation as required by Section 3700 of the Labor Code for the perfonnance of the work for which this permit is issued My workers compensation insfirance can-er and policy number are InsuranceCo VlfiA-^r'lC?\Q) C .^rvS UVovi^ Cf* PolicyNo ^ 1 "2- M ?>M Expiration Date "7_ I 7.^ [ | t-| Th|£ section need not be completed if the permit is for one hundred dollars ($100) or less Certificate of Exemption I certify that in the perfomiance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fmes up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damagesa^rovided for in Section 3706 ofthe Labor code, interest and attomey's fees ^eS" CONTRACTOR SIGNATURE f >L>^ ASC^ JSQGENT DATE fli / terefcy affimi fhaf / an'i exempf from Contractor's Ucense Law for the following reason I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however the building or improvement is sold within one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I I I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement tDYes j |NO 2 I (have / have not) signed an application for a building permit tor the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) ^PROPERTY OWNER SIGNATURE GENT DATE \ Is the applicant or future building occupant required to submit a^business [jlan^cutely hazardous matenals registration form or nsk management and preventon program under Sections 25505 25533 or 25534 of the ^"resley Tanner Hazardous Substance Account AcP ' Yes cP''' )m1ne air Yes ^S^o , the applicant or future building occupant required to obtain a permit froniihe air pollution control distnct or air quality management distncP Is the facility to be constructed within 1,000 feet of the outer boundary of a school site'' , Yes " j^No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lender's Address I certi^ that I have isad the application and state thatthe above infomiation is oonBCt and that the infoimation on the plans is accurate I agree to complywith all City oidmances and State laws relating to building consttuction I hereby authorize representative ofthe City of Carlsbad to enter upon the above mentioned property Ibr inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA pennit is required for excavations over S'O deep and demolitKin or constmction of stmctures over 3 stones in height EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or vwrk authorized by such penrnt is not commenced within 180 days from the date of such pemnit or if the buildiilg or WDri< authonzed by such pennit is suspended or abandoned at any time after the woik is commenced for a penod of 180 days (Section 106 4 4 Unilbnn Building Code) ygf APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CERTIFICATE OF OCCUPAMCY fCommercial Projects Onf Fax (760) 602-8560, Email buildinataicarlsbadca aov or Mail the completed form to Citv of Carlsbad, Buildina Division 16 35 Faraday Avenue, Carlsbad, Califomia 92008 C0# (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX ElVIAIL OCCUPANT'S BUS LIC No DEUVERY OPTIONS PICK UP CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) IVIAIL TO CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg 1) MAIL/FAX TO OTHER _ ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION , CHANGE OF USE / NO CONSTRUCTION ^g? APPLICANT S SIGNATURE DATE City of Carlsbad VALUATION WORKSHEET Building Division Permit No: i^ddress AssessoiPc-irccI No. SFD and Duplexes $110 17 $0 00 Residential Additions $131 73 $0 00 Remodels / Lofts $57 48 $0 00 Apartments & Multi-family $98 20 $0 00 Garages/Sunrooms/Solanums $28 74 $0 00 Patio/Porch/Carport $9 58 $0 00 Enclosed Patio $15 51 $0 00 Decks/Balconies/Stairs $15 57 $0 00 Retaining Walls, concrete,masonry $19 16 $0 00 Pools/Spas-Gunite $40 72 $0 00 Tl/Stores, Offices 3792 $37 12 $140,759 04 Tl/Medical, restaurant, H occupancies $50 30 $0 00 Photovoltaic Systems/ # of panels $400 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 $0 00 Fire Spnnkler System $3 11 $0 00 Air Conditioning - commercial $5 03 $0 00 Air Conditioning - residential $4 19 $0 00 Fireplace/ concrete, masonry $3,855 98 $0 00 Fireplace/ prefabricated Metal $2,621 34 $0 00 $0 00 $0 00 TOTAL $140,759 04 Valuation: $140,759 Comm/Res (C/R): 0 Building Fee $856 34 Plan Check Fee $599 44 Strong Motion Fee $30 00 Green Bldg Stand Fee $4 00 Green Bldg PC Fee $150 00 License Tax/PFF $4,926 57 License Tax/PFF (in CFD) $2,561 81 CFD 1st hour of Plan CheckFire Expedite Plumbing TBD Mechanical TBD Electncal TBD CFD 0 Yes (PFF= 1.82%) 0 No (PFF = 3 5%) Land Use. Density Improve Area: Fiscal Year Annex Year. Factor' CREDITS PFF and/orCFD Explanation: EsGil Corporation In (Partnership wtth government for (BuiCding Safety DATE 5/1/13 q.,APPUaANT JURIS JURISDICTION City of Carlsbad ^"TtTikPrREViEWER • FILE PLAN CHECK NO PC13-22 SET II PROJECT ADDRESS 192^ Palomar Oaks Way Suites 200 and 250 PROJECT NAME National Search Associates - TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to IAI EsGll Corporation staff did not advise the applicant that the plan check has been completed I I EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person n REMARKS By Doug Moody (by KC) Enclosures EsGll Corporation • GA • EJ • PC 4/25/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (partnership -with government for (BuiCding Safety DATE 4/9/13 • APPLICANT JURISDICTION City of Carlsbad • PLAN'REVIEWER • FILE PLAN CHECK NO PC13-22 SET I PROJECT ADDRESS ^i^2S-Palomar Oaks Way Suites 200 and 250 PROJECT NAME National Search Associates - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to fonward to the applicant contact person X The applicant's copy of the check list has been sent to Maggetti Elam / Victona Melvin 3160 Camino Del Rio South Suite 207, San Diego, CA 92108 I I EsGll Corporation staff did not advise the applicant that the plan check has been completed IX EsGll Corporation staff did advise the applicant that the plan check has been completed Person contacted Victona Melvin Telephone # 619-624-0512 ext 14 Date contacted '^l/of,5(by fc:^,) Email victona(5).maggettielam com Fax # 619-624-0530 & Mail ^Telephone y^ Fax In Person • REMARKS By Doug Moody Enclosures EsGll Corporation • GA • EJ • PC 4/1/13 9320 Chesapeake Dnve, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad PC13-22 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO PC13-22 JURISDICTION City of Carlsbad OCCUPANCY B USE Office TYPE OF CONSTRUCTION IIIB ACTUAL AREA 3792sf ALLOWABLE FLOOR AREA STORIES 2 HEIGHT SPRINKLERS'? Yes OCCUPANT LOAD 87 REMARKS DATE PLANS RECEIVED BY JURISDICTION 3/2713 DATE PLANS RECEIVED BY ESGIL CORPORATION 4/1/13 DATE INITIAL PLAN REVIEW COMPLETED 4/9/13 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required pnor to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. City of Carlsbad PC 13-22 Please make all corrections on the onginal tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGll Corporation is complete 1 Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code 2 Provide a section view of all new intenor glazed partitions at conference room 213 Show a) Please provide the ICC listing and installation information b) Method of attaching top and bottom plates to structure c) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing 3 Please clarify the mechanical plan to show the new HVAC unit to be installed? Please provide an equipment schedule Section 107 2 4 Please review the requirements, revise the plans appropnately and impnnt on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans 5 Provide complete energy designs for the proposed changes in the mechanical systems Provide the completed MECH- forms showing energy compliance 6 The completed and signed MECH-1 forms must be impnnted on the plans 7 Please sign and date the statement on sheet TI-0 2 of the plans that as the designer the restrooms serving the area of tenant improvement and path of travel to the area of improvement have been reviewed and fully comply with the current disabled accessibility requirements if not please provide complete plans and details showing the restrooms and path of travel to be brought into compliance City of Carlsbad PC13-22 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please bnefly descnbe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes • No • The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you EsGil Corporation In (Partnership wtth government for (BuiCding Safety DATE 04/09/13 • APPLICANT • JURIS JURISDICTION Encinitas • PLAN REVIEWER • FILE PLAN CHECK NO enl3-405,407 SET I PROJECT ADDRESS 1951 Avenida Joaquin PROJECT NAME Pena 4200 Watt Solar Photovoltaic System I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to I I Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Alex Sink Telephone # 619-857-9209 Date contacted (by ) Fax # Mail Telephone Fax In Person E-mail asink@solarcity com • REMARKS By John Le Vey Enclosures EsGll Corporation • GA • EJ • PC 04/02/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Encinitas enl3-405,407 04/09/13 GENERAL PLAN CORRECTION LIST JURISDICTION Encinitas PLAN CHECK NO enl3-405,407 PROJECT ADDRESS 1951 Avenida Joaquin DATE PLAN RECEIVED BY DATE REVIEW COMPLETED ESGIL CORPORATION 04/02/13 04/09/13 REVIEWED BY John Le Vey FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review IS based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department or other departments The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations The approval of the plans does not permit the violation of any state, county or city law • Please make all corrections and submit two new complete sets of pnnts to ESGIL CORPORATION • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please bnefly descnbe them and where they are located on the plans Have changes been made not resulting from this list? • Yes • No Encinitas en13-405,407 04/09/13 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: John Le Vey ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) 1 Please provide an approved method for the re routing of the plumbing vent(s) the method you are showing is not an approved method, please provide an alternate method , for approval Note: If you have any questions regarding this Electncal and Energy plan review list please contact John Le Vey at (858) 560-1468 To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans The following note should be given with each correction list Please make all corrections on the ongmal tracings, as requested in the correction list Submit two complete sets of plans For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Encinitas Building Department, 505 S Vulcan, Encinitas, CA 92024, (760) 633-2730 The City will route the plans to EsGil Corporation and the Encinitas Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Encinitas Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete City of Carlsbad PC13-22 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO PC13-22 PREPARED BY Doug Moody DATE 4/9/13 BUILDING ADDRESS 1925 Palomar Oaks Way Suites 200 and 250 BUILDING OCCUPANCY B TYPE OF CONSTRUCTION IIIB BUILDING PORTION AREA (Sq Ft) Valu ation Multiplier Reg Mod VALUE ($) Tl 3792 37 12 140,759 Air Conditioning Fire Spnnklers TOTAL VALUE 140,759 Junsdction Code cb By Ordinance Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance $856 34 $556.62 Type of Review 0 Complete Review • Structural Only Q Re petit ve Fee ~ Repeats • Other l~l Hourly EsGfl Fee Hr @* $479 55 Comments Sheet 1 of 1 macvalue doc + CITY OF PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 w/ww carlsbadca gov DATE: 03/28/13 PROJECT NAME: NATIONAL SEARCH ASSOCIATES I PLAN CHECK NO: 1 VALUATION: $140,759 SET#: 1 ADDRESS: 19^ PALOMAR OAKS WY PROJECT ID: PC 13 22 APN: 212-091-iUr^l ^ '^'^ I I This plan check review is complete and has been APPROVED by the ENGINEERING J Division. By: KATHLEEN LAWRENCE 03/28/13 A Final Inspection by the Division is required !.jYes L/JNO 1 This plan check review is NOT COMPLETE. Items missing or incorrect are listed on —' the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked te - ,'k '760-602*46101" / !¥^ENGINlERI!^G-^'Vr! "'fi i^%4imQ-602i2750#5t', f- *?! €^^^m^(im665,\: J:U ''•->;*i''"?r'P,y<'#»'®^ '•^•'f.^Hi.!k/ r Chris Sexton 1 1 760-602-4624 Chris Sexton@carlsbadca fiov j yl Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca fiov 1 1 Greg Ryan L _ J 760-602-4663 Gregory Rvan@carlsbadca fiov j j Gina Ruiz 1 760-602-4675 Gma Ruiz@carlsbadca fiov 1 ~l Linda Ontiveros ' ' 760-602-2773 Lmda Ontiveros@carlsbadca fiov 1 1 Cindy Wong '• — 760-602-4662 Cvnthia WonfiOcarlsbadca fiov • 1 1 Dominic Fien ' ' 760-602-4664 Dominic Fieri@carisbadca gov Remarks: W CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www carlsbadca gov ENGINEERING Plan Check for PC 13-22 Date 03/28/13 Project Address 1925 PALOMAR OAKS WY APN 212-091-41 Project Description Tl OFFICE TO OFFICE Valuation $140,759 ENGINEERING Contact Kathleen Lawrence Phone 760-602-2741 Email kathleen.lawrence@carlsbadca.gov Fax 760-602-1052 ] RESIDENTIAL INTERIOR [Zl TENANT IMPROVEMENT LJ RESIDENTIAL ADDITION MINOR (<$20,000.00) PLAZA CAMINO REAL [ J CARLSBAD PREMIER OUTLETS • COMPLETE OFFICE BUILDING iOTHER: CELL ANTENNAS OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY. KATHLEEN LAWRENCE DATE- 03/28/13 REMARKS NO ADDITIONAL ENG. FEES-BUILDING AT 100% SEE BOOK €-36 Notification of Engineering APPROVAL has been sent to via EMAIL on 03/28/13 Page 1 of 1 REV 4/30/11 ^ CITY OF STORM WATER COMPLIANCE ASSESSMENT B-24 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www carlsbadca gov am applying to the City of Carlsbad for the following type(s) of construction permit ^ Building Permit • Right-of-Way Permit Wiviy project IS categorically EXEMPT from ^ ^ the requirement to prepare a storm water pollution prevention plan (SWPPP) because it only requires issuance of one or more of the following permit types Electrical Fire Additional Fire Alarm Fixed Systems Mechanical Mobile Home Plumbing Patio/Deck Photo Voltaic Re-Roofing Sign Spa-Factory Spnnkler Water Discharge Project Storm Water Threat Assessment Criteria* Wo Theeat Assessment Cnteria yj My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because it meets the "no threat" assessment criteria on the City s Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier Level My project does not meet any of the High Moderate or Low Threat cntena descnbed below Tier1 - Low Threat Assessment Cntena • My project does not meet any of the Significant or Moderate Threat cntena, is not an exempt permit type (See list above) and the project meets one or more ofthe following critena • Results in some soil disturbance and/or • Includes outdoor construction activities (such as saw cutting, equipment washing, matenal stockpiling, vehicle fueling, waste stockpiling) Tier 2 - Moderate Threat Assessment Criteria • My project does not meet any of fhe Significant Threat assessment Cntena descnbed below and meets one or more of the following cntena • Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15 16 of the Carlsbad Municipal Code), or, • Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following cntena • Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or • Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or • Disturbed area is located along or within 30 feet of a storm dram inlet, an open drainage channel or watercourse, and/or • Construction will be initiated dunng the rainy season or will extend into the rainy season (Oct 1 through Apnl 30) T/ef3 - Significant Threat Assessment Critena • My project includes cleanng, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas and/or • My project is part of a phased development plan that wili cumulatively result in soil disturbance totaling one or more acres including any associated construction staging, equipment storage, refueling and maintenance areas or, • My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant potential for contnbuting pollutants to nearby receiving waters by way of storm water runoff or non-stonn water discharge(s) / certify to the best of my knowledge that the above checked statements are true and correct I understand and acknowledge that even though this project does not require preparation of a construction SWPP, I must still adhere to, and at all times during construction activities for the permit type(s) check above comply with the storm water best management practices pursuant to Title 15 ofthe Carlsbad Municipal Code and to City Standards *The City Engineer may authorize minor variances from the Storm Water Threat Assessment Cnteria in special circumstances where it can be shown that a lesser or higher Construction SWPPP Tier Level is warranted Assessor Parcel No Project Acidress Owner/Owners Authorized Agent Name A^^UV/ w Owner/Owner s Authorized Agejjt^ignature City Conjwrrence QNO 3 Title Dale Project ID B-24 Page 1 of 1 Rev 03/09 \ 4^1 CITY OF : ARLSBAD CONSTRUCTION THREAT ASSESSMENT WORKSHEET FOR DETERMINATION OF PROJECT'S PERCEIVED THREAT TO STORM WATER QUALITY E-33 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www carlsbadca gov Construction SWPPP Tier Level Construction Threat Assessment Criteria* Perceived Threat to Storm Water Quality Tiers Tier 3 - Hiqh Construction Threat Assessment Cntena XJ Project site is 50 acres or more and grading will occur dunng the rainy season • Project site is 1 acre or more in size and is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA • Soil at site IS moderately to highly erosive (defined as having a predominance of soils with USDA-NRCS Erosion factors kf greater than or equal to 0 4) • Site slope IS 5 to 1 or steeper • Construction is initiated dunng the rainy season or will extend into the rainy season (Oct 1 through Apnl 30) • Owner/contractor received a Storm Water Notice of Violation within past two years High Tiers Tier 3 - Medium Construction Threat Assessment Cntena • All projects not meeting Tier 3 High Construction Threat Assessment Cntena Medium Tier 2 Tier 2 High Construction Threat Assessment Cntena • Project IS located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA • Soil at site IS moderately to highly erosive (defined as having a predominance of soils with USDA-NRCS Erosion factors kf greater than or equal to 0 4) • Site slope IS 5 to 1 or steeper • Construction is initiated dunng the rainy season or will extend into the rainy season (Oct 1 through Apnl 30) • Owner/contractor received a Storm Water Notice of Violation within past two years • Site results in one half acre or more of soil disturbance High Tier 2 Tier 2 - Medium Construction Threat Assessment Critena Medium Tier 2 • All projects not meeting Tier 2 High Construction Threat Assessment Cntena Medium Tier 1 Tier 1 - Medium Inspection Threat Assessment Cntena • Project IS located within the Buena Vista or Agua Hedionda Lagoon watershed, within or directly adjacent to an environmentally sensitive area (ESA) or discharges directly to an ESA • Soil at site is moderately to highly erosive (defined as having a predominance of soils with USDA-NRCS Erosion factors kf greater than or equal to 0 4) • Site slope IS 5 to 1 or steeper • Construction is initiated dunng the rainy season or will extend into the rainy season (Oct 1 through Apnl 30) • Owner/contractor received a Storm Water Notice of Violation within past two years • Site results in one half acre or more of soil disturbance Medium Tier 1 Tier 1 - Low Insoection Threat Assessment Cntena Low Tier 1 Q All projects not meeting'Tier 1 Medium Construction Threat Assessment Cntena Low Exempt , , ' - Not Applicable -Exempt *The city engineer may authorize minor vanances from the construction threat assessment cntena in special circumstances where it can be shown that a lesser or higher amount of storm water compliance inspection is warranted in the opinion of the city engineer E-33 Page 1 of 1 REV 4/30/10 4. CITY OF CARLSBA PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1535 Faraday Avenue (760) 602-4610 www carlsbadca eov DATE: 3-28-13 PROJECT NAME: PROJECT ID: PLAN CHECK NO: PC 13-22 SET#: 1 ADDRESS: 192^ Palomar Oaks Way APN: 212-091-11 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. I I This plan check review is NOT COMPLETE, Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: victoria@maggettielam.com For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chns Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov 1 1 Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 1 Gma Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov n Cindy Wong 760-602-4662 Cvnthia Wong@carlsbadca gov • • 1 1 Dominic Fieri 760-602-4664 Dominic Fieri@carlsbadca gov Remarks: office to office - no new roof mounted HVAC BUILDING DEPZ DATE: 05/15/2013 PROJECT NAME: NSA & Spec Suite PLAN CHECK NO: 2 SET#: 1 ADDRESS: 1921 PALOMAR OAKS WY PROJECT ID: PC130022 APN: • This plan check review is complete and has been APPROVED by the FIRE Division. By: GR A Final Inspection by the FIRE Division is required ^ Yes n No This plan check review is NOT COMPLETE. Items missing ci incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: Applicant Yow may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the Issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked M,: .--PLANNING' . ,76^02,46101*^^.^' -': -iElSlNE^ING^ • 760^02-27,5? . ... ,.<rC^'^ Flf^BRiVENTlON^. '-*^760-602-4665 i 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov X Greg Ryan 760-602-4663 Gregorv Ryan@carisbadca gov 1 1 Gma Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 1 -nda Ontiveros@carlsbadca gov 1 1 Cindy Wong 760-602-4662 Cynf^ia Wong@carlsbadca gov • • 1 Dommic Fieri 760-602-4664 Dommic Fieri@carlsbadca gov Remarks- SEE ATTACHED Carlsbad Fire Department Plan Review Date of Report Requirements Category PLANCK 05-15-2013 Reviewed by Name Address VICTORIA MELVIN 3160 CAMINO DEL RIO SOUTH STE 207 SAN DIEGO CA 92108 Permit # PC130022 Job Name Job Address NSA & SPEC SUITE - OFF TO OFF 1921 PALOMAR OAKS WY CBAD Please review carefully all comments attached. CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: w/ COMMENTS THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW > NOTE Fire Alarm submittals shall be a deferred submittal and this plan shall be approved prior to any ceiling inspections > A Pre-dawn or dark-hours test of the emergency lighting shall be conducted by CFD staff prior to FINAL inspection Entry 05/15/2013 By GR Action AP BLDG. DEPT COPY ^'^'^ of 2 CONDITIONAL RECOMMENDATION FOR APPROVAL OVER THE COUNTER CONDITIONS Remove Keyed Construction Note 5 sheet T1-2.0 Room was reduced to SSm. Slip sheet E-1 revised means of egress illumination foot-candles near exit in area 214. Daryl K. James & Associates, Inc Checked by: Darvl Kit James 205 Co//na Terrace Date: Mav 6, 2013 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT Victoria Melvm JURISDICTION: Carlsbad Fire Department PROJECT NAME. NSA & Spec Suite ADDRESS: 1921 Palomar Airport R-d 200/250 PROJECT DESCRIPTION: PCI 3-22 1210] Suite 200 (Spec), 3,671 iS Suite 250 (NSA) Tenant Improvement, new demising partition, intenor partitions, new power & data, new ceiling grid, 2 new sinks, increase in lighting load Spec Suite This plan was reviewed in order to venfy conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The items below require correction, clanfication or additional information before this plan check can be approved for permit issuance CORRECTIONS Each sheet in the plans must signed by the person responsible for their preparation, even if there are no structural changes Business and Professions Code Engineenng sheet to be stamped and signed •TI-0.0 Project Data Justify the omission of Suite 205 It appears that demolition and construction will take place in Suite 250 Building Data Revise No of Floors to 2 Deferred Submittals Add Fire Alarm System 2010 CFC 907 including CFC 907 2 sections specific to occupancy groups and 2010 NFPA 72 •T1-0.3 Note the occupant load factor for each area Justify determined occupant loads for Reception areas 200 & 214 and Break/Data 218 T1-2.0 • Denote Storage Room 202 as an incidental, accessory use area and show construction compliance in accordance with CBC 508 2 5 Room size reduced to SScn N/A • Provide symbol for full height smoke resistant walls under Construction Plan Legend with a reference to full height wall details N/A Remove Keyed Construction Note 5. Room was reduced to 98m Over the counter correction. Door & Window Schedule •Rl symbolizes a pair door The floor plan shows doors tagged as Rl are single doors Please revise • Denote N3 door as being equipped with self-closing device and smoke seals CBC 508 2 5 2 N/A Floor Plan • Denote type and location of fire extinguisher(s) CFC 906 Page 2 of 2 •Tl-1-5 0 Provide specifications and California State Fire Marshal listings as well as other acceptance cntena for flame spread and smoke developed index for new carpet, padding and carpet base CFC 804 Provide specifications and California State Fire Marshal listings and other acceptance critena for flame spread and smoke developed index for wall finish material and rubber base CBC 803 •Tl-1-6.0 Detail 3 Rated wall detail to include ICC evaluation report #, UL Listing or reference to Item number in 2010 CBC Table 720 1(2) If penetrating any rated assemblies, provide details including fireproofing product listings Provide a wall detail in accordance with CBC 508 2 5 2 (Storage Room 202) N/A E.1 •Add the following note The means of egress system shall be illuminated at all times with a level not less than 1 foot-candle at the walking surface Indicate means of egress illumination that denotes means of egress illumination throughout the Means of Egress System, which consists of the Exit Access, Exit and Exit Discharge The exit access is that portion of the means of egress system that consists of all floor areas that lead from usable spaces within the building to the exit or exits serving that floor area Exit access begins at the furthest points within each room or space and ends at the entrance to the exit, that portion of the means of egress system between the exit access and the exit discharge or public way E-1-EM Demonstrate that the lighting plan complies with CBC 1006 2 for the means of egress system within the permitted area from the exit access to the extenor exit discharge Slip sheet revised means of egress illumination foot- candles near exit in area 214. Deputy Fire Marshal, Greg Ryan can be contacted at 760-602-4665, for clarification • M0.1 & MO 2 Denote air-moving systems supplying air in excess of 2000 cfm equipped with smoke detectors approved and listed by the California State Fire Marshal CMC 609 N/A Denote units provided with smoke detectors on plans N/A Denote smoke dampers in air transfer openings in Accessory Incidental Use Storage Room 202 CBC 711 7 N/A END OF COMMENTS BLDG. DEPT COPY Page 1 of 2 PLAN CHECK COMMENTS 2 Daryl K. James & Associates, Inc Checked by: Darvl Kit James 205 Co//na Terrace Date: Apnl 26. 2013 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Victona Melvin JURISDICTION: Carlsbad Fire Department PROJECT NAME: NSA & Spec Suite ADDRESS;>9^Palomar,£^arn?d^0^50 PROJECT DESCRIPTION: PCI 3-22 12151 Suite 200 (Spec), 3,671 m Suite 250 (NSA) Tenant Improvement, new demising partition, intenor partitions, new power & data, new ceiling gnd, 2 new sinks, increase in lighting load Spec Suite This plan was reviewed in order to venfy conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The items below require correction, clanfication or additional information before this plan check can be approved for permit issuance PLEASE ADDRESS ALL REMAINING COMMENTS WRITTEN IN BLUE FONT. RESUTOffALlfSTRUCflQNST • All corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates • Provide a written response following each comment, on this correction list, explaining how and where each plan review comment has been addressed • Provide a copy of original Building Department (EsGil) comments Input fire revisions onto the corrected Building Dept plan check set • Please direct any questions regarding this review to Daryl K James 760-724-7001 or kitfire@sbcglobal net - COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS, NO SIGNATURE REQUIRED.TO AVOID DELAY: DARYL K JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 CORRECTIONS Each sheet in the plans must signed by the person responsible for their preparation, even if there are no structural changes Business and Professions Code Engineering sheet to be stamped and signed •TI-0.0 Project Data Justify the omission of Suite 205 It appears that demolition and construction will take place in Suite 250 Building Data Revise No of Floors to 2 Deferred Submittals Add Fire Alarm System 2010 CFC 907 including CFC 907 2 sections specific to occupancy groups and 2010 NFPA 72 Page 2 of 2 T1-0.3 Note the occupant load factor for each area Justify determined occupant loads for Reception areas 200 & 214 and Break/Data 218 •T1-2 0 Denote Storage Room 202 as an incidental, accessory use area and show construction compliance in accordance with CBC 508 2 5 Room size reduced to SSiti N/A Provide symbol for full height smoke resistant walls under Construction Plan Legend with a reference to full height wall details N/A Remove Keyed Construction Note 5 Room was reduce to SBiti | Door & Window Schedule • Rl symbolizes a pair door The floor plan shows doors tagged as Rl are single doors Please revise • Denote N3 door as being equipped with self-closing device and smoke seals CBC 508 2 5 2 N/A Nl symbolizes double doors on Construction Plan Door & Window Schedule symbols shows door Nl as a single door Please revise Floor Plan • Denote type and location of fire extinguisher(s) CFC 906 •Tl-1-5.0 Provide specifications and California State Fire Marshal listings as well as other acceptance cntena for flame spread and smoke developed index for new carpet, padding and carpet base CFC 804 Provide specifications and California State Fire Marshal listings and other acceptance cntena for flame spread and smoke developed index for wall finish matenal and rubber base CBC 803 •Tl-1-6.0 Detail 3 Rated wall detail to include ICC evaluation report #, UL Listing or reference to Item number in 2010 CBC Table 720 1(2) If penetrating any rated assemblies, provide details including fireproofing product listings Provide a wall detaii in accordance with CBC 508 2 5 2 (Storage Room 202) N/A iJ. •Add the following note The means of egress system shall be illuminated at all times with a level not less than 1 foot-candle at the walking surface Indicate means of egress illumination that denotes means of egress illumination throughout the Means of Egress System, which consists of the Exit Access, Exit and Exit Discharge The exit access is that portion of the means of egress system that consists of ail fioor areas that lead from usable spaces within the building to the exit or exits serving that floor area Exit access begins at the furthest points within each room or space and ends at the entrance to the exit, that portion of the means of egress system between the exit access and the exit discharge or public way E-I-EM Demonstrate that the lighting plan complies with CBC 1006 2 for the means of egress system within the permitted area from the exit access to the exterior exit discharge Justify omission of egress illumination foot-candles near exit m area 214. Deputy Fire Marshal, Greg Ryan can be contacted at 760-602-4665, for clarification • M0.1 &M0.2 Denote air-moving systems supplying air in excess of 2000 cfm equipped with smoke detectors approved and listed by the California State'Fire Marshal CMC 609 N/A Denote units provided with smoke detectors on plans N/A Denote smoke dampers in air transfer openings in Accessory Incidental Use Storage Room 202 CBC 7117 N/A END OF COMMENTS BLDG, DEPT COP V^g^ ^ ^ PLAN CHECK COMMENTS 1 Daryl K. James & Associates, Inc Checked by: Darvl Kit James 205 Co//na Terrace Date: March 29, 2013 Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net APPLICANT: Victona Melvin . "^^^^^^^'.jJ JURISDICTION: Carlsbad Fire Department PROJECT NAME: NSA & Spec Suite /V ^^X^ ADDRESS: J.9^Palomar-/^iirport Rd 200/250 PROJECT DESCRIPTION: PC13-22 1210] Suite 200 (Spec), 3,6710] Suite 250 (NSA) Tenant Improvement, new demising partition, intenor partitions, new power & data, new ceiling grid, 2 new sinks, increase in lighting load Spec Suite This plan was reviewed in order to venfy conformance to minimum requirements of codes adopted by the Carlsbad Fire Department The items below require correction, clarification or additional information before this plan check can be approved for permit issuance „^ ^ .^^^^^^^^^^^ ^^pg-p^YED:^Rl(^HECK sERVl5Eg • Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates • Provide a written response following each comment, on this correction list, explaining how and where each plan review comment has been addressed • Provide a copy of Building Department (EsGil) comments Input fire revisions onto the corrected Building Dept plan check set • Please direct any questions regarding this review to Daryl K James 760-724-7001 or kitfire@sbcglobat net • COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS, NO SIGNATURE REQUIRED,TO AVOID DELAY: DARYL K. JAMES & ASSOCIATES, INC. 205 COLINA TERRACE VISTA, CA 92084 CORRECTIONS Each sheet in the plans must signed by the person responsible for their preparation, even if there are no structural changes Business and Professions Code Engineenng sheet to be stamped and signed TI-0.0 Project Data Justify the omission of Suite 205 It appears that demolition and construction will take place in Suite 250 Building Data Revise No of Floors to 2 Deferred Submittals Add Fire Alarm System 2010 CFC 907 including CFC 907 2 sections specific to occupancy groups and 2010 NFPA 72 T1-0.3 Note the occupant load factor for each area Justify determined occupant loads for Reception areas 200 & 214 and Break/Data 218 Page 2 of2 T1-2.0 Denote Storage Room 202 as an incidental, accessory use area and show construction compliance in accordance with CBC 508 2 5 Provide symbol for full height smoke resistant walls under Construction Plan Legend with a reference to full height wall details Door & Window Schedule Rl symbolizes a pair door The floor plan shows doors tagged as Nl are single doors Please revise Denote Rl doors as being equipped with a rating label, self-closing device and smoke seals Denote N3 door as being equipped with self-closing device and smoke seals CBC 508 2 5 2 Floor Plan Denote type and location of fire extinguisher(s) CFC 906 Tl-1-5.0 Provide specifications and California State Fire Marshal listings as well as other acceptance cntena for flame spread and smoke developed index for new carpet, padding and carpet base CFC 804 Provide specifications and California State Fire Marshal listings and other acceptance cntena for flame spread and smoke developed index for wall finish matenal and rubber base CBC 803 Tl-1-6.0 Detail 3 Rated wall detail to include ICC evaluation report #, UL Listing or reference to Item number in 2010 CBC Table 720 1(2) If penetrating any rated assemblies, provide details including fireproofing product listings Provide a wall detail in accordance with CBC 508 2 5 2 (Storage Room 202) EJ. Add the following note The means of egress system shall be illuminated at all times with a level not less than 1 foot-candle at the walking surface Indicate means of egress illumination that denotes means of egress illumination throughout the Means of Egress System, which consists of the Exit Access, Exit and Exit Discharge The exit access is that portion of the means of egress system that consists of all floor areas that lead from usable spaces within the building to the exit or exits serving that floor area Exit access begins at the furthest points within each room or space and ends at the entrance to the exit, that portion of the means of egress system between the exit access and the exit discharge or public way Provide a PHOTOMETRIC plan of all accessible areas Demonstrate that the lighting plan complies with CBC 1006 2 for the means of egress system within the permitted area from the exit access to the extenor exit discharge Deputy Fire Marshal, Greg Ryan, is preparing Photometnc Plan Guidelines Please contact Greg for clarification of this requirement at 760-602-4665 M0.1 & MO 2 Denote air-moving systems supplying air in excess of 2000 cfm equipped with smoke detectors approved and listed by the California State Fire Marshal CMC 609 Denote units provided with smoke detectors on plans Denote smoke dampers in air transfer openings in Accessory Incidental Use Storage Room 202 CBC 711 7 End of Comments BUILDING ENERGY ANALYSIS REPORT PROJECT: NSA 1921 Palomar Oaks Wasy Suite 250 Carlsbad, CA 92008 Project Designer: Maggetti Elam 3160 Camino Del Rio South Suite 207 San Diego, CA 92108 (619)624-0521 Report Prepared by: Greater San Diego Air Conditioning Co Inc. 3883 Ruffin Rd Ste C San Diego , CA 92123 619-469-7818 Job Number: 4613 Date: 4/18/2013 The EnergyPro computer program has been used to perform the calculations summariEed in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards This program developed by EnergySoft, LLC - www energysoft com EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-1871033 40 ID 4613 TABLE OF CONTENTS Cover Page Table of Contents Fonn MECH-1-C Certificate of Compliance Form MECH-2-C Air & Water System Requirements Form MECH-3-C Mechanical Ventilation Form MECH-4-C HVAC Misc Prescriptive Requirements 1 2 3 11 14 15 EnergyPro 5 1 by EnergySoft Job Number ID 4613 User Number 6272 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Parti of5) MECH-IC Project Name NSA Date 4/18/2013 Project Address 1921 Palomar Oaks Wasy Suite 250 Carlsbad Climate Zone Tolal Cond Floor Area 4,346 Addition Floor Area n/a GENERAL INFORMATION Building Type • Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School Bldg 12 Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction O New Construction • Addition • Alteration Approach of Compliance • Component Overall Envelope Energy TDV • Unconditioned (file affidavit) Front Orientation N, E, S, W or m Degrees Odeg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Cnteria Meets Cntena or Requirements Equipment^ Inspection Cnteria Pass Fail - Describe Reason^ Item or System Tags (le AC-1, RTU-1, HP-1) DNT-32 • • Equipment Type^ Packaged DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 16,397 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 37,873 Btu/fir • • Cooling Efficiency' 13 0 SEER/12 8 EER • • Duct Location/ R-Value Attic, Ceiling Ins, vented/4 2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment^ Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Pass Fail - Descnbe Reason' Item or System Tags (le AC-1, RTU-1, HP-1) DWr-33 • • Equipment Type^ Packaged DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 15,419 Btu/hr • • Mimmum Heating Efficiency' 7 70 HSPF • • Max Allowed Cooling Capacity' 45,739 Btu/hr • • Cooling Efficiency' 13 0 SEER/12 5 EER • • Duct Location/ R-Value Attic, Ceiling Ins, vented/4 2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1 If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from ihe building plans) the responsible party shall resubmit energy compliance (o include Ihe new changes 2 For additional detailed discrepancy use Page 2 of the Inspection Checklist Form Compliance fails if a Fail box is checked 3 Indicate Equipment Type Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-1ST10.33 40 ID 4613 Page 3 of 21 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 of 5) MECH-IC Project Name NSA Date 4/18/2013 Project Address 1921 Palomar Oaks Wasy Suite 250 Carlsbad Climate Zone Total Cond Floor Area 4,346 Addition Floor Area n/a GENERAL INFORMATION Building Type • Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School Bldg Bl Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction • New Construction • Addition • Alteration Approach of Compliance O Component Overall Envelope Energy TDV • Unconditioned (file affidavit) Front Orientation N, E, S, W or in Degrees Odeg HVAC SYSTEM DETAILS RELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Meets Cntena or Requirements Equipment^ Inspection Criteria Pass Fail - Describe Reason' item or System Tags (ie AC-1, RTU-1, HP-1) DNT-34 • • Equipment Type^ Packaged DX • • IMumber of Systems 1 • • Max Allowed Heating Capacity' 21,807 Btu/hr • • Minimum Heating Efficiency' 7.70 HSPF • • Max Allowed Cooling Capacity' 62,659 Btu/hr • O Cooling Efficiency' 13 0 SEER/121 EER • • Duct Location/ R-Value Attic, Ceiling Ins, vented/4 2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment^ Inspection Criteria RELD INSPECTION ENERGY CHECKLIST Equipment^ Inspection Criteria Pass Fail - Describe Reason' Item or System Tags (le AC-1, RTU-1, HP-1) DNT-35 • • Equipment Type^ Packaged DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 4,821 Btu/hr • • Minimum Heating Efficiency' 7 70 HSPF • • Max Allowed Cooling Capacity' 21,015 Btu/hr • • Cooling Efficiency' 13 0 SEER/IOO EER • • Duct Location/ R-Value Attic, Ceiling Ins, vented/4 2 • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • 1 If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or Irom the building plans) the responsible parly shall resubmit energy compliance to include the new changes 2 For additional detailed discrepancy use Page 2 of the Inspection Checklist Form Compliance fails if a Fail box is checked 3 Indicate Equipment Type Gas (Pkg or, Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other EnerqyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 4 of 21 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Parti of5) MECH-1 C Project Name NSA Date 4/18/2013 Project Address 1921 Palomar Oaks Wasy Suite 250 Cailsbad Climate Zone Total Cond Floor Area 4,346 Addition Floor Area n/a GENERAL INFORMATION Building Type El Nonresidential • High-Rise Residential O Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School Bldg IZl Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction • New Construction • Addition • Alteration Approach of Compliance • Component Overall Envelope Energy TDV O Unconditioned (file affidavit) Front Onentation N, E, S, W or in Degrees Odeg HVAC SYSTEM DETAILS FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Critena Meets Cntena or Requirements Equipment' Inspection Critena Pass Fall - Describe Reason' Item or System Tags (le AC-1, RTU-1, HP-1) DNT-36 • • Equipment Type' Packaged DX • • Number of Systems 1 • • Max Allowed Heating Capacity' 12,882 Btu/hr • • Minimum Heating Efficiency' 7 70 HSPF • • Max Allowed Cooling Capacity' 25,333 Btu/hr • • Cooling Efficiency' 13 0 SEER/12 8 EER • • Duct Location/ R-Value Attic, Ceiling Ins, vented / 4 2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS Wo • • Economizer No Economizer • • Thennostat Setback Required • • Fan Control Constant Volume • • Equipment' Inspection Criteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Criteria Pass Fail - Describe Reason' Item or System Tags (le AC-1, RTU-1, HP-1) DNT-37 • • Equipment Type^ Packaged DX • n Number of Systems 1 • • Max Allowed Heating Capacity' 23.551 Btu/hr • • Minimum Heating Efficiency' 7 70 HSPF • • Max Allowed Cooling Capacity' 47,899 Btu/hr • • Cooling Efficiency' 13 0 SEER/12 5 EER • • Duct Location/ R-Value Attic, Ceiling Ins, vented/4 2 • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer 0 • Thermostat Setback Required • • Fan Control Constant Volume • • 1 If the Actual installed equipment performance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes 2 For additional detailed discrepancy use Page 2 of the Inspection Checklist Form Compliance fails if a Fail box is checked 3 Indicate Equipment Type Gas (Pkg or, Split). VAV, HP (Pkg or split), Hydronic, PTAC, or other EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 5 of 21 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 1 of 5) MECH-IC Project Name NSA Date 4/18/2013 Project Address 1921 Palomar Oaks Wasy Suite 250 Carlsbad Climate Zone Total Cond Roor Area 4,346 Addition Floor Area n/a GENERAL INFORMATION Building Type Q Nonresidential • High-Rise Residential • Hotel/Motel Guest Room • Schools (Public School) • Relocatable Public School Bldg B Conditioned Spaces Unconditioned Spaces (affidavit) Phase of Construction • New Construction • Addition D Alteration Approach of Compliance • Component Overall Envelope Energy TDV • Unconditioned (file affidavit) Front Orientation N, E, S, W or in Degrees Odeg HVAC SYSTEM DETAILS RELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Cnteria Meets Cntena or Requirements Equipment' Inspection Cnteria Pass Fail - Descnbe Reason' Item or System Tags (I.e AC-1, RTU-1, HP-1) AC-1 • • Equipment Type' Split DX • • Number of Systems 1 • Max Allowed Heating Capacity' -570 Btu/hr • • Minimum Heating Efficiency' n/a • O Max Allowed Coolinq Capacity' 13,305 Btu/hr • • Cooling Efficiency' 13 7 SEER/II SEER • • Duct Location/ R-Value n/a • • When duct testing is required, submit MECH-4A & MECH-4-HERS No • • Economizer No Economizer • • Thermostat Setback Required • • Fan Control Constant Volume • • Equipment' Inspection Cnteria FIELD INSPECTION ENERGY CHECKLIST Equipment' Inspection Cnteria Pass Fai! - Descnbe Reason' Item or System Tags (le AC-1, RTU-1, HP-1) • • Equipment Type' • • Number of Systems • • Max Allowed Heating Capacity' • • Minimum Heating Efficiency' • • Max Allowed Cooling Capacity' • • Coohng Efficiency' • • Duct Location/ R-Value • • When duct testing is required, submit MECH-4A & MECH-4-HERS • • Economizer • • Thermostat • • Fan Control • • 1 If the Actual installed equipment perfomiance efficiency and capacity is less than the Proposed (from the energy compliance submittal or from the building plans) the responsible party shall resubmit energy compliance to include the new changes 2 For additional detailed discrepancy use Page 2 of the Inspection Checklist Form Compliance fajis if a Fail box is checked 3 Indicate Equipment Type Gas (Pkg or. Split), VAV, HP (Pkg or split), Hydronic, PTAC, or other EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 6 of 21 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 2 of 5) MECH-1 C Project Name NSA Date 4/18/2013 Discrepancies EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18X10 33 40 ID 4613 Page 7 of 21 CERTIFICATE OF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 3 of 5) MECH-1 C Project Name NSA Date 4/18/2013 Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans Listed below are all the acceptance tests for mechanical systems The designer is required to check the applicable boxes by all acceptance tests that apply and listed all equipment that requires an acceptance test If all equipment of a certain type requires a test, list the equipment descnption and the number of systems The NA number designates the Section in the Appendix of the Nonresidential Reference Appendices Manual that describes the test Since this form will be part of the plans, completion of this sechon will allow the responsible party to budget for the scope of work appropnately Building Departments: Systems Acceptance: Before occupancy permit is granted for a newly constructed building or space, or a new space-conditioning system serving a building or space is operated for normal use, all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance Systems Acceptance: Before occupancy permit is granted All newly installed HVAC equipment must be tested using the Acceptance Requirements The MECH-1 C form is not considered a completed form and is not to be accepted by the building department unless the correct boxes are checked The equipment requiring testing, person performing the test (Example HVAC Installer, TAB contractor, controls contractor, PE in charge of project) and what Acceptance test must be conducted The following checked-off forms are required for ALL newly installed equipment In addition a Certificate of Acceptance forms shall be submitted to the building department that certifies plans, specifications, installation, certificates, and operating and maintenance information meet the requirements of §10-103(b) and Title-24 Part 6 The building inspector must receive the properly filled out and signed forms before the building can receive final occupancy TEST DESCRIPTION MECH-2A MECH-3A MECH-4A MECH-5A MECH-6A MECH-7A MEGH-8A MECH-9A MECH-I OA MECH-11A Equipment Requiring Testing or Venfication Qtv Outdoor Ventilation For VAV & CAV Constant Volume & Single-Zone Unitary Air Distribution Ducts Economizer Controls Demand Control Ventilation DCV Supply Fan VAV Valve Leakage Test Supply Water Temp Reset Hydronic System Vanable Flow Control Automatic Demand Shed Control Fujitsu 12RL2ASUAOU 1 IZl m • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • n • • • • • • • • • • • • • • • • • ! • • EnerqyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 8 of 21 CERTIFICATE QF COMPLIANCE and FIELD INSPECTION ENERGY CHECKLIST (Part 4 of 5) MECH-1C Project Name NSA Date 4/18/2013 TEST DESCRIPTION MECH-12A MECH-13A MECH-14A MECH-15A Equipment Requiring Testing Qty Fault Detection & Diagnostics for DX Units Automatic Fault Detection & Diagnostics for Air & Zone Distnbuted Energy Storage DXAC Systems Thermal Energy Storage (TES) Systems Test Performed By Fujitsu 12RL2ASUAOU 1 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • n • • • • • • • • • • • EnerqyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 9 of 21 CERTIFICATE OF COMPLIANCE (Part 5 of 5) MECH-IC Project Name NSA Date 4/18/2013 Documentation Author's Declaration Statement certify that this Certificate of Compliance documentation is accurate and complete Name Company CL»^ (^i"lk/^p>y> Greater San Diego Air Conditioning Co Inc Date ZZZ^. 4/18/2013 Address 3883 Ruffin Rd Ste C GEA# GEPE# City/State/Zip San Diego, CA 92123 Phone 619-469-7818 The Principal Mechanical Designer's Declaration Statement • I am eligible under Division 3 of fhe California Business and Professions Code to accept responsibility for the mechanical design • This Certificate of Compliance identifies the mechanical features and performance specifications required for compliance with Title-24, Parts 1 and 6 ofthe California Code of Regulations • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application Name Ross Baillargeon Company Greater San Diego Air Conditioning Signature Date Address 3883 Ruffin Rd Suite C License # Clty/State/Zip san Diego, CA 92123 Phone (619)469-7818 Mandatory Measures Indicate location on building plans of Note Block for Mandatory Measures. MECHANICAL COMPLIANCE FORMS & WORKSHEETS (check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to tha 2008 Nonresidential Manual Note The Enforcement Agency may require all forms lo be incorporated onto the building plans IZl MECH-1 C Certificate of Compliance Required on plans for all submittals Ei MECH-2C Mechanical Equipment Summary is required for all submittals MEGH-3C Mechanical Ventilation and Reheat is required for all submittals with mechanical ventilatton El MECH-4C Fan Power Consumption is required for all prescnptive submittals EnergyPro 5 1 by EnergySoft User Number 6272 RunCode- 2013-04-18T10 33 40 ID 4613 Page 10 of 21 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name NSA Dale 4/18/2013 Item or System Tags (le AC-1, RTU-1, HP-1) Indicate Air Systems Type (Central, Single Zone, Package, VAV, or etc ) Item or System Tags (le AC-1, RTU-1, HP-1) DNT-32 DNT-33 DNT-34 Number of Systems 1 1 1 Indicate Paqe Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES T-24 Sections Heating Equipment Efficiency 112(a) 7 70 HSPF 7 70 HSPF 7 70 HSPF Cooling Equipment Efficiency 112(a) 13 0 SEER 712 a EER 130 SEER/12 5 EER 13 0 SEER 7121 EER HVAC Heat Pump Thermostat 112(b), 112(c) Yes Yes Yes Furnace Controls/Thermostat 112(c), 115(a) n/a n/a n/a Natural Ventilation 121(b) No No No Mechanical Ventilation 121 (b) 58 cfm 164 cfm 94 cfm VAV Minimum Position Control 121(0 No No No Demand Control Ventilation 121(c) No No No Time Control 122(e) Programmable Switch Programmable Switch Programmable Switch Setback and Setup Control 122(e) Setback Required Setback Required Setback Required Outdoor Damper Control 122(f) Auto Auto Auto Isolation Zones 122(3) n/a n/a n/a Pipe Insulation 123 Duct Location/ R-value 124 Attic, (filing Ins, vented/4 2 Attic, Ceiling Ins, vented/42 Attic, Ceiling Ins, vented/4 2 PRESCRIPTIVE MEASURES Calculated Design Heating load 144(a&b) 16.397 Btu/hr 15,419 Btu/hr 21,807 Btu/hr Proposed Heating Capacity 144(a&b) 14,917 Btu/hr 25,321 BtuMr 28,611 Btu/hr Calculated Design Cooling Load 144(a & b) 26,511 Btu/hr 32,017 Btu/hr 43,862 Btu/hr Proposed Cooling Capacity 144(a&b) 11,263 Btu/hr 17.202 Btu/hr 23,685 Btu/hr Fan Control 144(c) Constant Volume Constant Volume Constant Volume DP Sensor Location 144(c) Supply Pressure Reset (DDC only) 144(c) Yes Yes Yes Simultaneous Heat/Cool 144(d) No No No Economizer 144(e) No Economizer No Economizer No Economizer Heat Air Supply Reset 144(f) Constant Temp Constant Temp Constant Temp Cool Air Supply Reset 144(f) Constant Temp Constant Temp Constant Temp Electnc Resistance Heating' 144(g) Air Cooled Chiller Limitation 144(0 Duct Leakage Sealing If Yes, a MECH-4-A must be submitted 144(k) No No No 1 Total installed capacity (MBtu/hr) ol all electnc heat on this project exclusive of electric auxiliary heat for heat pumps If electric heat is used explain which exception(s) to §144(g) apply EnergyPro 5 1 by EnergySoft User Number 6272 RunCode. 2013-04-18T10 33 40 ID 4613 Page 11 of 21 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date NSA 4/18/2013 Item or System Tags (le AC-1, RTU-1, HP-1) Indicate Air Systems Type (Central, Smgle Zone, Package, VAV, or etc .) Item or System Tags (le AC-1, RTU-1, HP-1) DWr-35 DNT-36 DNT-37 Number of Systems 1 1 1 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value Indicate Pa ge Reference on Plans or Schedule and indicate the applicable exceptlon(s) MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value T-24 Sections MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 112(a) 7 70 HSPF 7 70 HSPF 7 70 HSPF MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 112(a) 13 0 SEER/WO EER 13 0 SEER/12 8 EER 13 0 SEER/12 5 EER MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 112(b), 112(c) Yes Yes Yes MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 112(c), 115(a) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 121(b) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 121(b) 100 cfm 77 cfm 151 cfm MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 121(c) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 121(c) No No No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 122(e) Programmable Switch Programmable Switch Programmable Switch MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 122(e) Setback Required Setback Required Setback Required MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 122(f) Auto Auto Auto MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 122{q) n/a n/a n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 123 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thermostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and Setup Control Outdoor Damper Control Isolation Zones Pips Insulation Duct Location/ R value 124 Attic, Ceiling Ins, vented/4 2 Attic, Ceiling Ins, vented/4 2 Attic, Ceiling Ins, vented/42 PRESCRIPTIVE MEASURES Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(3 & b) 4,821 Btu/hr 12,382 Btu/hr 23,551 Btu/hr Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(a&b) 18,054 Btu/hr 14,917 Btu/hr 25.321 Btu/hr Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(a & b) 14,711 Btu/hr 17,733 Btu/hr 33.530 Btu/hr Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(a & b) 12,409 Btu/hr 11,150 Btu/hr 17.441 Btu/hr Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(c) Constant Volume Constant Volume Constant Volume Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(c) Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(c) Yes Yes Yes Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(d) No No No Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(e) No Economizer No Economizer No Economizer Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(f) Constant Temp Constant Temp Constant Temp Calculated Design Healing Load Proposed Heating Capacity Calculated Design Cooling Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' 144(g) Air Cooled Chiller Limitation 144(l) Duct Leakage Sealing If Yes, a MECH-4-A must be submitted 144(k) No No No 1 Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electnc auxiliary heat for heat pumps If electric heat is used explain which exception(s) to §144(g) apply EnergyPro 51 by EnergySoft User Number 6272 RunCode. 2013-04-18T10 33 40 ID 4613 Page 12 of 21 AIR SYSTEM REQUIREMENTS (Part 1 of 2) MECH-2C Project Name Date NSA 4/18/2013 Item or System Tags (19 AC-1, RTU-1, HP-1) indicate Air Systems Type (Central, Single Zone, Packac e, VAV, or etc .) Item or System Tags (19 AC-1, RTU-1, HP-1) AC-1 Number of Systems 1 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value Indicate Page Reference on Plans or Schedule and indicate the applicable exception(s) MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value T-24 Sections MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(a) 137 SEER/11 SEER MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(b), 112(c) n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 112(c). 115(a) n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(b) Ocfm MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 121(c) No MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(6) Programmable Switch MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(e) Setback Required MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(f) Auto MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 122(g) n/a MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 123 MANDATORY MEASURES Heating Equipment Efficiency Cooling Equipment Efficiency HVAC Heat Pump Thennostat Furnace Controls/Thenmostat Natural Ventilation Mechanical Ventilation VAV Minimum Position Control Demand Control Ventilation Time Control Setback and S^up Control Outdoor Damper Control Isolation Zones Pipe Insulation Duct Location/ R-value 124 n/a PRESCRIPTIVE MEASURES Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(a& b) -570 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(a&b) 0 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(a & b) 9,313 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(a S b) 8.643 Btu/hr Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(c) Constant Volume Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(C) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(c) Yes Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(d) No Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(e) No Economizer Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(f) Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(f) Constant Temp Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(g) Calculated Design Heating Load Proposed Heating Capacity Calculated Design Coolmg Load Proposed Cooling Capacity Fan Control DP Sensor Location Supply Pressure Reset (DDC only) Simultaneous Heat/Cool Economizer Heat Air Supply Reset Cool Air Supply Reset Electnc Resistance Heating' Air Cooled Chiller Limitation 144(1) Duct Leakage Sealing If Yes, a MECH-4-A must be submitted 144(k) No 1 Total installed capacity (MBtu/hr) of ail sisotnc heat on this projecf exclusive of electric auxiliary heat for heat pumps If electric heat is used explain which exception(s) lo §144(g) apply EnergyPro 51 by EnergySoft User Number 6272 RunCode: 2013-04-18T10 33 40 ID 4613 Page13of21 MECHANICAL VENTILATION AND REHEAT MECH-3C Project Name NSA Date 4/^8/20^3 MECHANICAL VENTILATION (§121(b)2) REHEAT LIMITATION {§144(d)) AREA BASIS OCCUPANCY BASIS VAV MINIMUM A B C D E F G H 1 K L M N Zone/System Condition Area (ft^) CFM per ft^ Mm CFM By Area BXC Number Of People CFM per Person Mm CFM by Occupant EXF REQ'D VA Max of DorG Design Ventilation Air CFM 50% of Design Zone Supply CFM BX04 CFM/ft^ Max of Columns H, J, K, 300 CFM Design Minimum Air Setpoint Transfer Air Zone 2 385 015 58 58 58 DNT-32 Total 58 68 Zone 3 1,091 015 164 164 164 DNT-33 Total 164 164 Zone 4 625 015 94 94 94 DNT-34 Total 94 94 Zone 5 665 0 15 100 100 100 DNT-35 Total 100 100 Zone 6 512 015 77 77 77 DNT-36 Total 77 77 Zone 7 1,008 015 151 151 151 DNT-37 Total 151 151 Zone 1 60 0 15 9 9 0 9 AC-1 Total 9 0 Totals 1 Column 1 Total Design Ventilation Air C Minimum ventilation rate per Section §121, Table 121-A E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant load for egress purposes for spaces without fixed seating H Required Ventilation Air (REQ'D V A) is the larger of the ventilation rates calculated on an AREA BASIS or OCCUPANCY BASIS (Column D or G) I Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference J Desiqn fan supply CFM (Fan CFM) x 50%, or the design zone outdoor airflow rale per §121. K Condition area (ft^) x 0 4 CFM / ft^, or L Maximum of Columns H, J, K, or 300 CFM M This must be less than or equal to Column L and greater than or equal to the sum of Columns H plus N N Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M) Where required, transfer air must be greater than or equal to the difference between the Required Ventilation Air (Column H) and the Design Minimum Air (Column M), Column H minus M EnergyPro 51 by EnerqySoft User Number 6272 RunCode. 2013-04-18T10-33.40 ID 4613 Page 14 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Vanable Air Volume (VAV) Systems when using the Prescnptive Approach See Power Consumption of fan §144(c) B Fan Descnption Design Brake HP Efficiency Motor Dnve Number of Fans Peak Watts BXEX746/ (CXD) DWr-32 - Supply Fan 0 150 55 0% 97 0% 1 0 210 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 210 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) 600 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across Ihe fan (SP|) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across Ihe fan (SP|) on Line 5 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across Ihe fan (SP|) on Line 5 5) SP, B) Calculate Fan Adiuslment and enter on line 6 6) Fan Adjustment = 1-(SP,-1)/SP| C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0 350 W/CFM TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems EnergyPro 5 1 by EnergySoft User Number 6272 RunCode. 2013-04-18T10-33 40 ID 4613 Page 15 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescnptive Approach See Power Consumption of fan §144(c) A B Fan Description Design Brake HP Efficiency iViotor Dnve Number of Fans Peak Watts B X E X 746 / (CXD) DNT-33 - Supply Fan 0 200 60 0 % 970% 1 0 256 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 256 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) ^,000 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 5) SP, B) Calculate Fan Adjustment and enter on line 6 6) Fan Adjustment = 1-( SPa-1)/SP| C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0 256 W/CFM 1 TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 16 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescnptive Approach See Power Consumption of fan §144(c) A B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts BXEX746/ (CXD) DNT-34 - Supply Fan 0220 60 0% 970% 10 282 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 2S2 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) 1,200 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal thBn enter SPa on line 4 Enter Tolal Fan pressure drop across the fan (SP,) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal thBn enter SPa on line 4 Enter Tolal Fan pressure drop across the fan (SP,) on Line 5 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal thBn enter SPa on line 4 Enter Tolal Fan pressure drop across the fan (SP,) on Line 5 5) SP, B) Calculate Fan Adjustment and enter on line 6 6) Fan Adjustment = 1-( SPa-1)/SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0 235 W/CFM 1 TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems EnergyPro 5 1 by EnergySoft User Number 6272 RunCode- 2013-04-18T10 33 40 ID 4613 Page 17 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a tolal fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Vanable Air Volume (VAV) Systems when using the Prescnptive Approach See Power Consumption of tan §144(c) B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts BXEX746/ (CXD) DNT-35 - Supply Fan 0150 55 0% 97 0% 10 210 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 210 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) 800 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal Ihen enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal Ihen enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal Ihen enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 5) SP, B) Calculate Fan Adjustment and enter on line 6 6) Fan Adjustment = 1-( SPa-1)/SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0262 W/CFM 1 TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems \ EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18X10 33 40 ID 4613 Page 18 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescnptive Approach See Power Consumption of fan §144(c) B Fan Description Design Brake HP Efficiency Motor Dnve Number of Fans Peak Watts B X E X 746 / (CXD) DNT-36 - Supply Fan 0 150 55 0% 97 0% 1 0 210 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 210 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) 600 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 5) SP, B) Calculate Fan Adjustment and enter on line 6 6) Fan Adjustment = 1 -( SP, -1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0350 W/CFM TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems EnergyPro 6 1 by EnergySoft User Number 6272 RunCode. 2013-04-18T10 33 40 ID 4613 Page 19 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a total fan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using Ihe Prescnptive Approach See Power Consumption of tan §144(c) B Fan Description Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts B X E X 746 / (CXD) DNT-37 - Supply Fan 0200 60 0% 970% 10 256 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) 256 FILTER PRESSURE ADJUSTMENT Equation 144-A in §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) 1,000 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SP, on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SP, on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 4) SP, A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SP, on line 4 Enter Total Fan pressure drop across the fan (SP,) on Line 5 5) SP, B) Calculate Fan Adjustment and enter on line 6 6) Fan Adjustment = 1 -( SP, -1) / SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0 256 W/CFM TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems EnergyPro 5 1 by EnergySoft User Number 6272 RunCode 2013-04-18T10 33 40 ID 4613 Page 20 of 21 FAN POWER CONSUMPTION MECH-4C Project Name NSA Date 4/18/2013 NOTE Provide one copy of this worksheet for each fan system with a total tan system horsepower greater than 25 hp for Constant Air Volume (CAV) Fan Systems or Variable Air Volume (VAV) Systems when using the Prescriptive Approach See Power Consumption of fan §144(c) Fan Descnption Design Brake HP Efficiency Motor Drive Number of Fans Peak Watts BXEX746/ (CXD) AC-1 - Supply Fan 0 062 400% 99 0% 10 117 TOTALS AND ADJUSTMENTS FILTER PRESSURE ADJUSTMENT Equation 144-A m §144(c) of the Energy Standards 1) TOTAL FAN SYSTEM POWER (WATTS, SUM COLUM F) ff7 FILTER PRESSURE ADJUSTMENT Equation 144-A m §144(c) of the Energy Standards 2) SUPPLY DESIGN AIRFLOW (CFM) 400 A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the tan (SP,) on Line 5 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2) W/CFM A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the tan (SP,) on Line 5 4) SPa A) If filter pressure drop (SPa) is greater than 1 inch W C or 245 Pascal then enter SPa on line 4 Enter Total Fan pressure drop across the tan (SP,) on Line 5 5) SP, B) Calculate Fan Adjustment and enter on line 6 6) Fan Adjustment = 1-( SPa-1)/SP, C) Calculate Adjusted Fan Power Index and enter on Row 7 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' 0 292 W/CFM 1 TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0 8 W/CFM for Constant Volume systems or 1 25 W/CFM for VAV systems EnergyPro 5 1 by EnergySoft User Number 6272 RunCode- 2013-04-18T10 33 40 ID 4613 Page 21 of 21 ^ CITY OF CARLSBAD pmMB'JjJnn ECECTLiGAi.' ' MECjANtjCAD WDGDSQEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 . www carlsbadca gov Project Address: ^T& 2.^ PermitNc.; p6 IVZ'^ Informotlon provided bsiovi refers to work baing done on the oboue mentioned permit on^. This form mast be completed and returned to the Building Division before the permit tan ba issued. Building Dept Faxi ^60) 602-8538 o Number of new or relocated fixtures, traps, or floor drains New building sewer line? Ves No. Number of new roof drains? 0 Install/alter water line?... ^ Number of new water heaters? , Number of new, relocated or replaced gai outlets? Number of new hose bibs? ^ Residential Permits: New/expanded seruicei Number of new amps, Minor Remodel onfs/t Ves No Commerci al/Induttrl«lt Tenant Improuementi Number of eKisting amps involved in this pra/ecti N umber of new amps involved In this proiect. New Conttructioni Amps per Panel: Single Phase > , Number of new amperes Three Phase Numbei of new amperes Three Phase 480 , Number of new amperes Number of new furnaces, A/C, or hectt pumps? New or relocated duct worh? Yes No. Number of new fireplaces? Number of new exhaust fans?...... ..„.„.„.,., Relocate/install uent? Number of new exhaust hoods? ..i Number of new boilers or compressors? Number of HP B-ie Cage 1 of 1 RBV 03'09 CITY OF CARLSBAD PrnMBOUDD EDECTDECAm MECDANliiAD WDDDSDEET B-18 Deve!oi>ment Services Building Oivlston 1635 Faraday Avenue 760-602-2719 www carlsbadca gov Projecl Address: 1>T&E.y^ Permit No,: PC \%-7^ Information provided below refers to work being done on the above mentioned permit only This lorm must be completed and returned to tho Bvildlna PivisioM before the permit can ba Issued. Building Dept. Fax! (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains. New building sewer line? Number of new roof drains?...., Install/alter water line?„ , Number of new water heaters? Numbsr of new, relocated or reploced gas outlets?.. Number of new hose bibs? „. Ves No Residential Permits: New/expanded service: Number of new amps. Minor Remodel only: Ves No €ommereiaiyindu{triali Tenant Improvement: Number of ssisting amps Involved in this proied; Number of new amps rnvolvedln this project: New Construdion: Amps per Panel; Single Phase Number of new amperes_ Three Phase - Number of new amper6S_ Three Phase 480 Number of new ampere$_ 200 amps 125 amps Number of new furnaces, A/C, or heat pumps?. New or relocated duct work? .. Number of new fireplaces? ........... Number of new exhaust fans? - Relocate/install vent? , Number of new exhaust hoods? .Ves No Number of new boilers or compressors? „ Number of HP B-18 Page 1 of 1 Rev 03/09 CITY O F Paan/IBENDD EDECTDQKAm MECDANaSAD WnnnSnEET B-18 Deyei^.oment Services Building Division 1635 Faraday Avenue 760-602-2719 . www.carlsbadca.gov Project Address: 1>T& PermitNc; \>C Infomncllon provided below refers to work being done on the obove mentioned psrmft only This form must ba completed end relwraed io fhe Building Division before the aennit con faa issued. Buiiding Dept Fax (760) 602-6533 Number of new or relocated fixtures, traps, or floor drains, New building sewer line? „ ........ ,....„ Number of new roof drains?....,...,..,™. _ Install/alter water Ime? « Number of new water heaters? ,.,..„„ Number of new, relocated or replaced gas outlets? Number of new hose bibs? „_ — „ _ Ves No Resldenticd Pernittst New/expanded service: Number of new amps; Minor Remodel on^ Ves No Commereial/Induttricsh Tenant Improwement; Number of existing amps Involved(n ttiis proiect: Number of new amps invoSvecUti this project: Kaw Conftrudion: Amp; pet Panel; Single Phase — „. „.,„.„., Number of new ampenes_ Three Phase..... _ „.. ,...„ Number of new amperes_ Three Phase 480 , ~ ™. Number of new amp6res_ Number of new furnaces, A/C, or heat pumps?. New or relocated duct work? . „. Number of new fireplaces?.,,. Number of new exhaust fans? - ., Relocate/'Butail uent? .„.,„ Number of new exhaust hoods?.., . Number of new boilers or compressors? .Ves No .Number of HP B-18 Page 1 of 1 Rev. 03/09 Ac 3 2;V: 3 '•:'V SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE use ONLY UPFPiir W# BP DAFE / Business Manne Business CuiiSact Telephone # - /f>7 Project Address City Stale ^ Zip Code Willl/ifl Address Cily State Zip Code Project Contact Telephone* i ) The foDcwlng questions represent ttie fBclltty's activities, NOT ttie specific project doecrtptlon PART I. FIRg pePARTMEM- KAZAROOUS MATERIALS OIVISION! OCCUPANCY CLASSIFICATION- Indicate Dy circling itw Hem, whamsr your business WlH u9e, process or «»tsre any of lha following hszardous mnlsnals If any of Ihe items are circled, applicant must contact Ihe Fire ProiecUon Agency witn Juflsdlctton prior lo plan subminal Facility's Square Pootage (Including proposed prolecO: Occupancy RatJng. 1 ExplOSnrg or Blssbno Agenls 6 Organic Psrocides 2. Compi»jtiiiid G*s«» S 0)ddli6fS 3 Fbnimeblercombusllble Liquids 7 Pyrottiorics 4 Hsmirabls Solrds B Unalabla Reaclivss 9 Water Reactives (0. Cryogenics t1 Highly Toxie or loxicMateraia 12 Rsdloadives PART n. SAN DIEGO COUMTY DEPARTMBNT OP SNVIR0NIV1EHTA[. HEALTH - HA^AROOUS MATgRIALS PIV13IQN3 fHMDl. If lhe_an3Wcr ta sny of the aitons Is yas applicant must contact Ina CDL ' quoaitons Is yas applicant must coniacl lTi<j ciounly o( San Oiego Haiardous Matenals bluision 5500 overland Ave, Suite l io, San Dsego, CA 92'r23 Call (BS8) 505-6700 pnor lo the IMuencfl of ff building pemiit, FEES AR6 RSQgjRED Praject Completion Date. / / EnpectBd Dala of Occupancy '] ' / if) Dele Initials • CalARP Required Date inlUais (for now consiruciion or mmoaeiina pnjjgcS) Is your OLislriess listed on ine reverse side at this form' (eneck ail tnai apply) Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your Dusiness store or handle Haxardous Substances In quanllllcs equal ta or groQtcr than 55 gallons soo pounds 200 oifafc feel, or oercinogens'reprodLKlive toxins in any quantity? WiH your business uso an existing or Install an underground sioraga tank? Will your boBinesa store or handle Regulated Substances (CalARP)? Will your business use ot Install a Hazardous Wssia Tank Systani (\\W» 22 Article 10)? Will your busmees alore petroleum in tanks or container at your fadUty with a tolal atomge capsot/ ecjual lo or greater ihan 1,320 gallons' (California's Aboveground PatralauTn Storage Act) PART.JII SAN DIEGO CallNTY AIR POLLUTIQM CONTROL DISTRICT If IhS aniiWBr to sny of ths qusclians below Is yea. applicanl must contact Uie Air Pollution Control Distnct (APCO), 10-154 6W Srove Road, Sun Diego, CA 92131.1649, telephone (858) S8G-2600 pnorto Ibe Issuance of a huiWing or demolition permit Note If the answar to quasOons 4 or S Is yes applicanl must also submit an asbeslos nolHlcatlon form to Iho APCD at least 10 working days pncr lo cominanang demoWlnn or renovation, except ciRmnlibon or fynov^|ipi^ ofrescdenUal structures of (bur units or tees Contact ihe APCD for more infomiatian • CalAJ^P Exempt • CalARP Complala _I Oala inibala YES • • • • NO 1 will the subject facility or conslruc(io.T activHles Include operations or equlpmcnl (hat emit or are capable of emmtng an aif coiitamlnaftt? (Sea the APCD rscisnaat ai hltn./iwww agnprd org/infinffBn^^re^rmils ndf. and Ihe list of typical equipment requinng an APCD permil on the ceversc side of this from. Coniacl APCD If you have any quastloits} (ANSWER ONLY IF QUESTION 11S YES) Will the subject laciiily be located within 1.000 feet of the outer boundary of a school (K through My (Search the Califomia School Dlrsclory sl nttpy/wvyw cde ca oov/re/sd/ for public ana private schools or conlaci lha appropnate school distncf) Has a survey been porformad to dQiarmlna lha presenca of Asbasios ContaInlr\fl Materials' Wllf there be renovaiJon that Involves handling of any friable asbestos materials or disturbing any material iliai conlalns non-frlabie asbestos? Will there bo demolition Involving lha ramoval of a load supporting structural mamb*r? enefly deMtibe business aciivflies Idi re under peijally of psijuiy that la the best of Name of Ovmer o( Authorized Agent flies / ~~. ~TZ' ,/ DfieHy describe proposed projocf , lu^avMadge and bsUof the rosponsas msde riareln are true and cori^l Slgnaiiira af Owner or Aulhoni:a<i Ageni Dale PWe DB'ARTMErn" OCCUPANCY CUSSIFICATION. aY._ FOR OFFICIAL USE ONLY- DATE EXEMPTOR NO i^URTHERlNFaiWA'nON REQUIRCO RELEASED PORaUILOINC PBRUIT »UT NOf POR OCCUPANCIT neLEASSI FOI^ OCCUPANCY COUNiTY HI^D' APCO C0UNTY4^M0 APCO COUNTY-HMD APCO IIM-91?l(0:/ll) Coiint) of San Diego - DEH -Hazflfdoui Materials Division Serena Sakamoto From: Victona Melvin <victona(a)maggettielam com> Sent: Monday, April 08, 2013 2 24 PM To: Serena Sakamoto Cc: Janet Altar Subject: RE PC13-22 / 1925 Palomar Oaks Way Attachments: Permit Application pdf Categories: Yellow Category Hi Serena, i just noticed that the address is incorrect on the application I had written 1925, but it is actually 1921 Attached is the revised correct address for this project Please let me know if I need to do anything else to get this corrected at the city The title block on the plans is correct Thanks, Victona Melvin Project Manager/ Intenor Designer Maggetti Elam 3160 Camino del Rio South Suite 207 San Diego, Ca 92108 619 624 0521 x14 619 624 0530 fax victona@maqgettielam com From: Serena Sakamoto [mailto'Serena.Sakamoto(g)carlsbadca qovl Sent: Thursday, March 28, 2013 3:28 PM To: victona(S)maqqettielam.com Cc: Janet Altar Subject: PC13-22 / 1925 Palomar Oaks Way Attn Victoria Melvin We have 2 issues with the plan check for these 2 suites I left you a message regarding the first question What IS the total square footage for the spec suite #200 for 1925 Palomar Oaks Way' Also, the fire expedite fee of $115 has been created under CB130825 Please pay this as soon as possible Let us know if you have any questions Thank you. 5^ CtTY OF CARLSBAD Bui'Wfng Division Serena Sakamoto Technical Assistant City of Carlsbad INDUSTRIAL WASTEWATER DISCHARGE PERMIT ^ . SCREENING SURVEY DateV^lH> Business Name M^h^iA^ S^^r^ A^3<>C^r^-^^ Street Address <*12^ ?tf^(o/v^yA/L Oa|<, Oarti Czr *3'Z-Q06 Email Address U&^rigca f^^y jA^'^jUgfw^cg^ PLEASE CHECK HERE IF YOUR BUSINESS IS EXEIVIPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility Acid Cleaning Ink Manufactunng Nutritional Supplement/ Assembly Laboratory Vitamin Manufactunng Automotive Repair Machining/Milling Painting/Finishing Battery Manufacturing Manufacturing Paint Manufacturing Biofuel Manufacturing Membrane Manufactunng Personal Care Products Biotech Laboratory (i e. water filter membranes) Manufacturing Bulk Chemical Storage Metal Casting / Forming Pesticide Manufactunng / Car Wash Metal Fabrication Packaging Chemical Manufactunng Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroless plating Porcelain Enameling Electncal Component Anodizing Power Generation Manufactunng Coating (i e phosphating) Print Shop Fertilizer Manufactunng Chemical Etching / Milling Research and Development Film /X-ray Processing Pnnted Circuit Board Rubber Manufactunng Food Processing Manufactunng Semiconductor Manufacturing Glass Manufactunng Metal Powders Forming Soap / Detergent Manufactunng Industrial Laundry Waste Treatment / Storage SIC Code(s) (if known): Brief descnption of business activities (Production / Manufactunng Operations). Description of operations generating wastewater (discharged to sewer, hauled or evaporated) Estimated volume of industrial wastewater to be discharged (gal /day) List hazardous wastes generated (type / volume) Date operation began/or will begin at this location Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authonty'? Yes No If yes, when Site Contact Signature Title Ac^jCj/^X Phone No LU\- L1^%-0^'U. ENCINA WASTEWATER AUTHORITY, 6200 Avenida Enemas Carlsbad, CA 92011 (760)438-3941 FAX (760)476-9852 PC130022 1921 PALOMAR OAKS WY NSA & SPEC SUITE - OFF TO OFF CB130823 1921 PALOMAR OAKS WY 200 CB130825 250 1921 PALOMAR OAKS WY 3/2-"^//s. Tf ei^'^, eL-(^<^. e<,o,iu, i'P-iiZ^ ^<o, f/^/l^ SW •ISSUED •CV Approved Date, By BUILDING PLANNING i ^61]-^ ENGINEERING ^ FIRE Expedite? ( Y/I N ^)l5ll^> AFS Checked by HazMat APCD Health Forms/Fees sent Reed Due? By Encina '3/zn/i-2> Y N Fire Y N HazHealthAPCD Y N PE&M 'kiikU'-^ Y N School Y N Sewer Stormwater Y N Y N Special Inspecfion Y N CFD Y (N) LandUse Density ImpArea FY Annex Factor PFF Y (t^ Comments Date Date Date Date Building Planning Engineering Fire s/^-J/is Need? ' • Done • Done a Done