Loading...
HomeMy WebLinkAbout1921 PALOMAR OAKS WAY; 104; CB060280; Permit. 4:-..• .. - . 9 - • : -, - . . • • - City of ~Gaelsbaid, 1635 FaradayAv Carlsbad, CA92OO8.•- i- 05-04-2006 Commercial/Industrial Permit Permit No C13060280 Building lnspectionRequest Line (760) 602-2725 I I. - 4 Job Address 1921 PALOMAR OAKS WY CBAD St 104 Permit Type TI , Sub Type COMM Parcel No 2120911800 Lot# 0 Status - ISSUED Valuation - $34,125.06-11 * Construction Type NEW AppIied 02/06/2006 Occupancy Group -. Reference # "Entered By SB Project] itle REGENTS BANK 975 SF TI Plan Approved 05/04/2006 OFFICES/ BREAKROOM TO SAME Issued 05/04/2006 — flnspect Area 4 - - - ,'Plan Check#: - Applicant _Owner-.---... MONTELLO GEORGE . • PRENTISS PROPERTIES ACQUISITION PARTNERS LP -. C/OLYNNMINNICI 471560THST . 389OW NORTHWEST HWY#400 ' SAN DIEGO CA 92115 — DALLAS TXL75220 619229 0642 Building Permit. / .. $270:79 Meter Se SN . Add 'I Building Permit Fee ,/ $0'0'7, Add I Red )Nater Con Fee j 40.00 Plan Check 7 $176.01fr'Meter Fee \ C \ .. $000 ' 4 Add 'I Plan Check Fee / $0.00: ' ISDCWA Fee \ \ $0.00 Plan Check Discount . f . - $0.00 - CFDPaoffFeé- •..• . . $0.00 Strong Motion .Fee : I $7.17PEF(3105540 . v •'$O.00 - Park Fee' j / $0b0..PFF(4305540)i $o oUr LFMFee -. . $O.00 License•Tx(3i04193yt' )J - $0.00 Bridge Fee $000 BTD #2 Fee J $0 00 lraffic Impact Fee (3105541) $000 BTD #3 Fee $0 00 \ Traffilrnct Fee (4305541) J $0 00 Renewal Fee $0 00% PLUMBING TOTALr\ / I $000 Add I Renewal Fee $0 00 ELECTRICAL\TOTAL / I .,$35.00 Other Building Fee $0 00\ MECHANICALTOTAL' / I $24.00 S - d00_ I •- Pot. Water Con' . Fee . . • $0.00iMaster Drainage Fee j $0.00 (Meter Size / / J $000 AddI Pot. Water Càn.Fee . . $0.00 SRedi Parkiñg Fee $0.00 Recl Water Con Fee $0 00jçAdditionaL Fees $0 00 \ (R / - ... $512.97 Total Fees: ( $5i297 'BIanciDue: _ u 'BJJUD{NJPLANS ATTACHED .4. . 5- - . - , - - . .-: -, •--: . - . - '5 FINAL APPROVAL lnspect(. Date _____________ i ,clearance:. NOTICE Please take N6'TICE that approval of your project includes the imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for1 processing in accordance with Carlsbad Municipal Code Section 332030 Failure to timely follow that procedure will bar any subsequent legal action to attack review, set aside void or annul their imposition ' 4- - You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning,'zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this or as to which the statute of limitations has previously otherwise exoired - I. - -•• .•• ,. .•.- 4 . . .. ••,• .5 . . .. s.i_•. - . - . -.. - - - -4. - - .5 • -,•._ , e ,. 5-. - - . - S : • -. --:'--- ... . -S. -a'. 4 1 • 4 4 _S.. 4 0603701-1 0026 02/06/2006 001 11 PERMIT APPLICATION I PLAN-CHECK,o-o2 EST VAL.!l-~'fir CITY OF CARLSBAD BUftDING DEPARTMENT-—,,Plan Ck Deposit - - - Validated By__ * Date 2i6/cL TTIOM Address (include Bldg/Suite #) '.' ness Name (at this address)"' Legal Description.. -, ' Lot No.'' . Subdivision Name/Number " - "'Unit No. Phase No:, Total # of units - I Assessor's Parcel # •' .: .Exise .'. ' '•,," . . ,,, ;. " Proposal U,s, '...' IL Description of Work * / '''.. SQ. FT.,-' . . #of'Storiés # of Bedrooms '' # of Bathrooms , I' 5' .tLX1fr " T3T r 7-oiNdiffeir—At5from 1 cr f ov Name -Ad- ress C t State/Zip Telephone # F x F !3 AW'1 I C&ctr gent "Contrac OwneT' fl Agent for Ov.n r e.j' - tfrITh1 7— riLr Q Name .'.'... Address . City Stat 7, Tvlvpory P (Pr JADt ] Marne Address ,. fj City '. State/Zip . Telephone# " ISec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structue, prior. to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s LicenseLaw lchepter,9, commending with Section 7000 of Division 3 of the Business and Professions. Code], or: rri that he is exepttheréfrrn o, and the basis for the. alleged exemption Any violation of Section 7031:5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 11$5001) , . 0' ' ' . . . '.....•''"" :' 5' Name Address City State/Zip F Telephone # State License # i Licenile Class ' City Business License ' Designer Name .. , , Address - . ',.,., , City State/Zip Telephone i s License ,# ' *WORS_QLSTIQ!r1 ._ Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations 1 0 I have and will maintain a certificate of consent Ao self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued - , - . I -have and will maintain workers'Scompensation as required by Section 3700 of the Labor Code; for the performance of the work for which this 'permit is ( issued My worker's compensation insurance carrier and policy number are 4' .................. ... .- ,--.-. ..................-'. . . . ....................... Insurance Company . . Policy No. , ., Expiration Date _ , '. . ....VC (THIS SECTION NEED NOT. BE COMPLETED IF THE. PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS)' o CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner- so as to become subject to the Workers Compensation Laws of California Tit WARNING: Failure to secure workers' compensation coverage is unlawful; and shall, subject an employer to-criminal penalties and civil finesT up to one hundred 4 thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest,and attorney s fees. i,'SIGN'ATURE . ... DATE 1WF JI LDEEtARATIOIiJ Ldi I hereby affirm that I am exempt from the Contractor's License Law for the following reason 0 I, as owner of the property or my employees with wages as their sole compensation, will do, the work and the structure is, not intended or offered for sale"' e. (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who, does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). ...............' ' '!. , 0 I as owner, of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The :r'Cóntractor's' Licensle Law does not apply to an owner of pro'perty"who builds or improves thereon, and contracis for such projects, with contractor(s) !icensed pursuant to the Contractor's License Law) ' I I :0. I am exempt under Section Business and Professions Code for this reason A. I personally plan to provide the major labor and materials for construction of the proposed property improvement 0 YES NO, 2 'I '(have / have not) signed an application for a building permit for the proposed work'.- 13 I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number / contractors license numbed .-.'-i 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise ard provide the major work (include name I address / phone number I contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / types of work): ' ,,, ,,, ,,• .,,,,. ,, ,,, 'I ,,.,'. ,,,,,, . ",, ' ',*, ' . ,. . ', PROPERTY OWNER SIGNATURE . 1DATE d.. low NG!007M.—ITS : :771 - Is the applicant or future building occupant required to submit a'business plan, acutely hazardous materials registration form-or risk management vnl prevvnrion . y.program under Sections. 25505, 25533 or 25534 of the Presley-Tanner. Hazardous Substance Account-Act? 0: YES 0 N0', Is the applicant 0r1'future building 'occupant required to obtain a permit m fro the air pollution control district or air quality managementdistrict? YES EJ NO is the facility to be constructed within 1 000 feet of the;outer boundary of a school site? ,.0 YES E NO 1 IF ANY OF THE ANSWERS ARE YES; A FINAL CERTIFICATEOF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS1 MET'OR IS MEETING THE*4 :.. :REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES'AND THE AIR POLLUTION CONTROL DISTRICT [81cONSTRUcTION_LENDING_AGENCY 'I hereby affirrn.that there is a construction lending agency for the oerforimance of the 'ork for v,hich thy' p'rrnit IS v' red (Sec 3097(,) Civil Code) LENDER'S NAME L- APPUCANT 1.ERFICN -. I certify that [have read the application 'and state that the above information is correct ind that the information on the plans is'accurate) I agree t complij vith all S City,ordinancesand State laws relating to building 'construction, I hereby authorize representatives of, the 'Cit'. of, to enter upon the .above mentioned i .1 property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY. OF CARLSBAD, AGAINST ALL LIABILITIES," 'JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN'CONSEQ1ENCE OF THE GRANTING OF THIS PERMIT., OSHA An OSHA it perm is required for excavations over 5'0" deep and demolition or construction of structurés over 3 stories in height ' EXPIRATION: Every permit issued byihe building Official under. the .provisionof this Code shall expirsl by limitatiorfand become 'null and void if the building or work , : authorized by such permit is not commenced within 180 da from the date of such permit or lithe building oii,work authorized by su permit is suspended or abandoned',''' APPLidANTSSIGNATURE at any time after the work is comrnenc ysS:tion__10644_UniformBuildingCode) A/&N TE WHITE File YELLOW Applicant PINK Finance I' I a - City of Carlsbad Bldg Inspection Request For: 06/29/2006 Permit# CB060280 Inspector Assignment: PD Title: REGENTS BANK 975 SF TI Description: OFFICES! BREAKROOM TO SAME Type: TI Sub Type: COMM Phone: 6194545583 Job Address: 1921 PALOMAR OAKS WY Suite:. -.104 Lot 0 .. Location: Inspector : APPLICANT MONTELLO GEORGE . Owner: -. Remarks: Total Time: . . . Requested By: NA Entered By: BINSPECT CD Description •• Act Comment .19 Final Structural 4' 29 Final Plulithing . 39 Final Electrical . 49 Final Mechanical Comments/Notices/Hold. . . Associated PCRs/CVs Original PC# - Inspection History Date Description . Act Insp comments . 06/16/2006 14 Frame/Steel/Bolting/Welding AP TP T CElL 06/16/2006 34 Rough Electric AP TP CElL LITES 06/16/2006 44 Rough/Ducts/Dampers . AP TP DUCTS . 05/15/2006 17 Interior Lath/Drywall AP PD . . . . 05/09/2006 14 Frame/Steel/Bolting/Welding • AP PD WALLS . 05/09/2006 34 Rough Electric AP PD . • - 05/05/2006 21 Underground/Under Floor AP PD • 05/05/2006 24 Rough/Topout AP PD 21N FOR SINK . - r - - - ,Oft oICarIshad .. y. Final Building Insoection - -. : Dept: Building Engineering Planning CMWD St Lite F..ke Plan Check #: Date: 06/29/2006 Permit #: CB060280 - • Permit Type: TI . • Project Name: REGENTS BANK 975 SF TI Sub Type: COMM OFFICES/ BREAKROOM TO SAME • . Address: - 1921 PALOMAR OAKS WY #104 a Lot: 0 Contact Person NA Phone: .6194545583 • - Sewer 01st: CA - • • Water Dist: CA Inspected — 1.) Date • • By: 1L-7iLL,J Inspected: Approved: ,Disapproved: Inspected '— Date • By: Inspected: Approved:.______ Disaproved: Inspected Date • S By: Inspected: • Approved: Disapproved: _____ • Comment S. .• - .5 - 1. .. S i--.- -- EsGul Corporation - In Partners/lip with Government for Building Safety DATE: May 2, 2006 APP ANT UJURI JURISDICTION: City of Carlsbad U PLAN REVIEWER U FILE' PLAN CHECK NO. 06-0280 SET: III ' • PROJECT ADDRESS: 1921 Palomar Oaks Pkwy Suite 104 PROJECT NAME: Regents Bank - TI - The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. - - - The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. - V: LI .The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. . LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. , The applicant'&côpy of the check list has been sent to: : V Esgil Corporation staff did not advise the applicant that the plan chck has been completed. . LI Esgil Corporation staff did advise the applicant that the plan check has been completed. :. Person contacted: - * . Telephone #: ' •• Date contacted:,'(by ) Fax ,#: Mail Telephone , Fax In Person - •: - LI REMARKS - By:.Bryan Zuppiger ' Enclosures Esgil Corporation • . EGA' [:],MB LI EJ [I] PC LOG . • .. •' , .'. - V . '• . . trnsmtl.dot 'V ''• V - V • V; V 4 1 9320 Cheapeak Drive; Suite 208• San Diego, California 92123• (858) 5601468• Fx (858)560-1576 "V - - V, V -: -- -' •' •1' , V V - , •V ' , .• * - . • ' .' '' V EsGul Corporation In (Partnership with government for(Building Safety DATE:April 24, 2006 . LI APPLICANT _PINA IS JURISDICTION: City of Carlsbad EVIEWER UFILE 'PLAN CHECK NO.: 06-0280 SET: II . . -. PROJECT ADDRESS: 1921 Palomar Oaks Pkwy Suite 104 PROJECT NAME: Regents Bank - Ti . * LI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. .. , .., LII. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans'trànsmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. .. . . 'U The check list transmitted herewith is for your information. The plans are being held at Esgil ' Corporation until corrected plans are submitted for recheck The applicaht's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. 'U The applicant's copy of the check list h been sent to: ' .. . Kim Castle 4715 601h Street, San Diego, CA 9211,5 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check-has been completed. Person contacted: Ki Castle ' . .. Telephone #: 619-994-5557 , Date contacted: 'I/B(bY() '. Fax #: 619-229-0642 ' Mail Telephone Fax—" in Person LI REMARKS: . ' :.; " *.•', By Bryan Zuppiger Enclosures Esgil Corporation . . :LI GA El -MB E EJ E PC 04/17/06 trnsmti.dot . ( 9320 Chesapeake Drive Suite 208 • San Diego California 92123 • (858)'560-1468 • Fax (858) 560-1576 JURISDICTION: City of Carlsbad . PLAN CHECK NO.: 06-0280 PROJECT ADDRESS 1921 Palomar Oaks Pkwy Suite 104 SET: II DATE PLAN RECEIVED BY '. ' ,. - DATE RECHECK COMPLETED: ESGIL CORPORATION: 04/17/06 * . * ' - April 24, 2006 - . .• ' - .' .4.. ' . REVIEWED BY: Bryan Zuppiger - ' . '- ' . • -4 FOREWORD (PLEASE READ) This plan review is limited to'.the technical requirements contained in the Uiiiform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws arid, ordinances enforced by the Planning Department, Engineering Department or other departments The following *,items. listed need. clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or •' citylaw. ' , .• ,. , . . A: Please make all corrections on the original tracings and submit new complete sets of prints to: ,• 'See next page. '. . .' ••• ft '•' B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised. plans C.; The following ithrns have'. not been resolved from the previous plan reviews. The original ' correction number has been given for your reference. In case you did not keep a copy of the prior correction 'list, we, have enclosed those pages containing the outstanding corrections. Please contact me-if you have any questions regarding these items. D' Please indicate here if any changes have been made to the plans that are not 'a result of:, corrections from this list. If there are other changes, please briefly describe them and where they - are located on the plans. Have changes been made not resulting from this list? * , •' , .'- UYes LINO 4 4 4'. .' • , , - , 4 4_ ft - ' •- • City of Carlsbad 06-0280 April'24, 2006 Please make all corrections on the original tracings, as requested in the correction list Submit 'three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: .1; Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)602-2700. The City will' route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire - Departments * 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2.' Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits Unable to locate on the plans 3.1 Please indicate on the plans the location of the required automatic shut-off controls and over- ride switch for the lighting as per Title 24, Part 6, Section 131(d) Unable to locate on the plans The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code). To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.; * The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the" * plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you r ' * ci .. EsGil Corporation .. In Tartnership with govement for Ouifding Safety DATE: 2/16/06 U APPLICANT S. JURISDICTION: .City of Carlsbad U PLAN REVIEWER -: E3 FILE PLAN CHECK NO.: 06-0280 SET: I PROJECT ADDRESS: 1921 Palomar Oaks Pkwy Suite 104 PROJECT NAME: Regents Bank - TI. • F The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes., .;• LII The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list• and should be corrected and resubmitted for a complete recheck. - • The check list transmitted herewith is for your information. The plans we being held at Esgil Corporation until corrected plans are submitted for recheck. • The applicant's copyoMhe check list.is enclosed for the jurisdiction to forward to the applicant contact person. -. - The applicant's copy of the check list has been sent to: - Kim.Castle • - :- . 4715 60 th Street, San Diego, CA 92115 • Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kim Castle Telephone #: 6199945557, . * Date contacted: L\1-0\e (by: ') ) Fax # 619-229-0642 Mail Teiephone. -Fax"Tin Person • LI REMARKS: - H • : - -: • - By: Doug Moody - Enclosures: • - • Esgil Corporation• •. '• - •• ..' • .• ' GA LI MB LI EJ 171 PC 2/7/06 trnsmtl dot - 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 • • - 1 • PLAN CHECK NO 06-0280 / JURISDICTION City of Carlsbad OCCUPANCY :B USE Office TYPE OF CONSTRUCTION JuN ACTUAL AREA 823sf ALLOWABLE FLOOR AREA STORIES 1 A HEIGHT F SPRINKLERS? YES OCCUPANT LOAD 19 REMARKS DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY F JURISDICTION 2/6/06 ESGIL CORPORATION 2/7/06 DATE INITIAL PLAN REVIEW PLAN REVIEWER Doug Moody COMPLETED 2/16/06 FOREWORD (PLEASE READ) - This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sc 1064 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw dot I t ) - * City of Carlsbad 06-0280 - 2/16/06 Please make all corrections on the original tracings, as requested in the correction • list. Submit three sets of plans for commercial/industrial projects (two sets of plans ' . for residential projects). For expeditious processing, corrected sets can be . submitted in one of two ways: - - 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) • 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad • Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. 'Deliver all remaining sets of plans and calculations/reports directly to the City of • Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. - NOTE:. Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete I Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 editions of the California Building/Plumbing/Mechanical Codes and the 2004 edition of the California Electrical Code, which adopt the 1997 UBC, 2000UMC, 2000 UPC and the 2002 NEC. 2, Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be, installed in all flexible conduits". 3. Please indicate on the plans the location of the required automatic shut-off • controls and over-ride switch for the lightingas per Title 24, Part 6, Section • 131(d). • . 4.- Please have the principle designer check the appropriate box(s) in the Statement of Compliance System Acceptance section of the LTG-1 -C part .4 of 4 documents. • • 5 Indicate the location on the plans of the approved fixture to receive the main • condensate discharge from air conditioning units. (UMC Section 309) 0 - 6. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing duct work; please note or • show mechanical ventilation will be provided capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1. T. Please revise the plumbing plans to show the hew sink to gravity drain.to the sanitary waste system per 709 of the UPC - •. • ; V V .. City of of Carlsbad 06-0280- V V * 2/16/06 V To.speed up the review process, note on this list (ora copy) where each V correction item has been addressed, i.e., plan sheet, note or detail number, V calculation page, etc. .• V .. V V V Please indicate here if any changes have been made to the plans that are not a V V r result of corrections from this list. If there are other changes, please briefly V V V • . describe them and where they are.located in the plans. • V V V . V Have changes been made to the plans not resulting from this correction list? V V Please indicate: . V • • V V Yes NoU . - V . V V *V • V V 0 V . V • V • V' •V• * V The jurisdiction has contracted with Esgil Corporation located at 9320 V Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of V 858/560-1468, to perform the plan review for your project. If you have any V V ; questions regarding these plan review items, please contact Doug Moody at V Esgil Corporation. Thank you. - V • V V • • : - .• . . . V - V V •V • V * . • V VV •V City of Carlsbad 06-0280 2/16/06 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 06-0280 PREPARED BY: Doug Moody DATE: 2/16/06 BUILDING ADDRESS: 1921 Palomar Oaks Pkwy Suite 104 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: JuN BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 823 City Valuation 34,125 Air Conditioning, Fire Sprinklers TOTAL VALUE 34,125 Jurisdiction Code cb By Ordinance' $270.791 I Bldg. Permit Fee by Ordinance Fan check Fee byordinance 1 , I $176.o1I Type of Review:' Complete Review Structural Only LII Other E Repetitive Fee Repeats ' Hourly , Hour ESgil Plan Review Fee $151 .641 Comments: Sheet of 1 macvalue.doc Carlsbad Fire Department Plan Review Requirements Category:. TI, COMM Date of Report: 02-08-2006 * Reviewed by: Name: Address: S ñiB08? S. / Job Name: REGENTS BANK 975 SF TI Job Address: 1921 PALOMAR OAKS WY CBAD St: 104 time, this office cainiot standards. Please rcview INCOMPLETE The item have for is incomplete. you submittod review At this to determine adeguately conduct a rc'iew compliance with the applicable codes andlor carefully all Please ti% with changes "clouded", oommenta attaohcd. caubrnit necessary plans and/or specifications, t0-this office for review and approval: Conditions: Cond: C0N0001087 [MET] APPROVEDTHIS PROJECT HAS BEEN REVIEWED AJSD APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE S AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. - THIS APPROVAL SHALL NOT BE HELD TO PERMIT S S OR APPROVE THE VIOLATION OF ANY LAW. . Entry: 02/08/2006 By: GR Action: AP 4.