HomeMy WebLinkAbout1921 PALOMAR OAKS WAY; 300; CB090649; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-04-2009 Commercial/Industrial Permit Permit No: CB090649
Building Inspection Request Line (760) 602-2725
Job Address 1921 PALOMAR OAKS WY CBAD St: 300
Permit Type TI Sub Type: INDUST
Parcel No 2120911800 Lot# 0 Status. ISSUED
Valuation $331870.00 Construction Type- 5B Applied: 04/20/2009
Occupancy Group: Reference #: Entered By: JMA
Project Title: INTEGRITY APP.. 9482 SF OFFICE Plan Approved: 06/04/2009
TO OFFICE Issued 06/04/2009
Inspect Area
Plan Check#:
Applicant: Owner:
DOWNLING CONSTRUCTION .. COGNAC PLAZA L L C
5735 KEARY VILLA RD C/O PRUDENTIAL REAL ESTATE INVEST
#103 4 EMBARCADERO CTR #2700
SAN DIEGO, CA 92123 SAN FRANCISCO CA 94111
858-279-7988
Building Permit $1,490.41 Meter Size
Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00
Plan Check $968.77 Meter Fee $000
Add'l Plan Check Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $0.00
Strong Motion Fee $6969 PFF (3105540) $0.00
Park Fee $000 PFF (4305540) $0.00
LFM Fee $0.00 License Tax (3104193) $0.00
Bridge Fee $000 License Tax (4304193) $0.00
BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00
BTD #3 Fee $000 Traffic Impact Fee (4305541) $000
Renewal Fee $000 PLUMBING TOTAL $4100
Add'I Renewal Fee $0.00 ELECTRICAL TOTAL $185.00
Other Building Fee $0.00 MECHANICAL TOTAL $60.00
Pot. Water Con. Fee $000 Master Drainage Fee $0.00
Meter Size Sewer Fee $0.00
Add'I Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00
Red. Water Con. Fee $0.00 Additional Fees $0.00
Green Bldg Stands (SB1473) Fee $12.00 HMP Fee ??
TOTAL PERMIT FEES $2,826.87
Total Fees. $2,826 87 Total Payments To Date. $2,826 87 Balance Due: $0.00
kjL4 1r'r J1J
N STORAGE
ATTACHED
____
FINAL APPROVAL
Inspector: Date 97 Clearance:
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as feesIexactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
City of Carlsbad Plan Check No. t33Q L9
1635 Faraday Ave., Carlsbad, CA 92008
760-602-2717/ 2718/ 2719
0a'
Est. Value 3'31, ,?71 ________________
Plan Ck. Deposit 3. Fax: 760-602-8558
Building Permit Application Date q. (o (o °t cj ivv\
JOB ADDRESS Jf'j foifi'ni'k' SuITE#/SPACE#/uNIT# APN I CT/PROJECT# 1LOT# 1 PHASE # J#OFUNITS 1#11E 1#BATHROOMS 1TENAN I uubmtSS Nmit CONSTR'I'PE 0CC GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
Thc (fri
ce
'.
GARAGE (SF) PATIOS (SF) DECKS (SF) Fl R1E AIRCONDITIONING I FIRE SPRINKLERS
SOMEONE_________________________________
IPRO L I YES NOW YESNOII YESNOE
CONTACT NAME (if Different FOm Applicant)
ADDRESS ADDRESS 1~2 f "A -~F14W CITY STATE ZIP CITY STATE I ZIP 42ff PHONE FAX
PHONE 6 ,ZAX &.726
EMAIL EMAIL
- Li o-
CONTRACTOR BUS NAME ?ROPERTYOWNERNAME
APPLICANT NAME c#ic.tv•• -
i/p4 l--(ej--
ADDRESS
( j ADDRESS
_______________ CITY StATE ZlP47 CITY q ZIP Alti
(2. PHONE PHONE' FAX 19 AX EMAIL f SX 7I
,
EMAIL
ARCFVDESIGNV ___r ____________________ STATE LIC# 7'RT CLASS I CITY IA i
toec ruji. o ousrness anorroxessions i.00e: Afl ciry Or UOUflt wnicn requires a permit to construct, alter, improvo, demolish or repair anystructure, prior to its ifsiihnce. also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License LawfChapter 9, commending with Sction 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for ape su ects the a aDt tea civil penalty of not more than five hundred dollars ($500)) \ I _)P1 [ I.
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the fo!lowirç declarations
Ell have and will maintain a certificate of consent to self.insure for workers' compensatIon as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued
I have and will maintain workers' compensation, as required bSchon 370001 the Labor Code, for the performance of the work for which this permit is sued My workers' compensation insurance carner and policy
number are* Insurance Co_J&€.tIT IJc2* Policy No Expration Data r( L
Nl
section need not be completed if the permit is for one hundred dollars ($10 or less
Certificate of Exemption: I certify that in the perform of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
omia WARNING: Failure to se re workers' co p sation coverage is unlawful, and shall subject an employer to criminal penalties and cijl finT p to one hundred thousand dollars (&100,000), in
addition to the coat of compeisatio , n1ag as pro I fd?in Section 3706 of the Labor code, interest and attorney's fees. (
CONTRACTOR SIGNATURE DATE (, j -( ) 9
I hereby affirm bat am exempt from Confracto?s License Law for the following reason'
[J I, an owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered lbr sale (Sec 7044, Business and Protessions Code The Contractor's
License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sate If, however, the building or improvement Is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). [] I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code. The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contiactofs License Law)
[] I am exempt under Section _____________Business and Professions Code for this reason.
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (:Jves I:jio
2 I (have! have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone! contractors' license number).
4 I plan to provide portions of the work, bull have hired the following person to coordinate, supervise and provide the major work (include name! address / phone I contractors' license number).
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name! address / phone! type of work)
.'PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a businesWiag, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? [J Yes Lmo
Is the applicant or future building occupant required to obtain a permit froln the air pollution control district or r ty management district' I:Iyes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' I:JYes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED S THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
[CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code).
Lender's Name Lenders Address
tILAPPLICANT—CERTIFI C ATI O N
I ceribfythatl have read the application and state thatthe above information Is correct and thatthe infonnabon an the plans is accurate. I agreeta complywith all City ordinances and State laws ,elabngto building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned pro pe for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN A A ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavate over 50' deep and demolition or co utho 5 over 3 stones in height
EXPIRATION Every permit issued by the Buildin th vise IN s I re by itation and become nut and mid tithe building or work authorized by such permit is not commenced within
180 days from the date of such permit or tithe ing or a said on rrnti i ded abandoned at any time after the work acommenced for period of 180 days (Section 10644 Uniform Building Code)
A5APPLICANTIS SIGNATURE DATE A j _I--- - 4-17-M
V V -
City of Carlsbad Bldg Inspection Request
For. 08/27/2009
Permit# CB090649 Inspector Assignment: RB
Title: INTEGRITY APP.: 9482 SF OFFICE
Description: TO OFFICE
Type: TI Sub Type: INDUST
Phone: 6199934160
Job Address 1921 PALOMAR OAKS WY
Suite: 300 Lot 0
Location: Inspector:
APPLICANT DOWNLING CONSTRUCTION
Owner:
Remarks: a lease
Total Time: Requested By: MARK
Entered By: CHRISTINE
CD Description Act Comments
19 Final Structural 9 P' f r€- 4QS s,ie_d" C PP
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
CV970015 CLOSED EXPIRED BLD PERMIT CB940766,
PCR93010 APPROVED ADD/2X2 LIGHTS/REMOVE 13 CANS, ADD 4 OUTLETS RELOCATE SINK
Inspection History
Date Description Act Insp
07/21/2009 84 Rough Combo PA RB
07/15/2009 17 Interior Lath/Drywall CA RB
07/13/2009 17 interior Lath/Drywall AP RB
07/08/2009 14 Frame/Steel/Bolting/Welding AP RB
07/08/2009 24 Rough/Topout AP RB
07/08/2009 34 Rough Electric AP RB
06/25/2009 17 Interior Lath/Drywall AP RB
06/25/2009 24 Rough/Topout NR RB
06/18/2009 17 Interior Lath/Drywall PA RB
06/17/2009 14 Frame/Steel/Bolting/Welding AP RB
06/17/2009 17 Interior Lath/Drywall PA RB
06/09/2009 14 Frame/Steel/Bolting/Welding PA RB
Comments
OK TO DROP TILES - SEE JOB CARD
DONE
COMPLETED
WALLS ONLY COMPLETED
COMPLETED
WALLS ONLY COMPLETED
1ST PHASE
SEE JOB PLANS
ON CORRECTIONS
SEE JOB OLANS
City of Carlsbad
Finil Building Inspection
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check#: Date: 08/27/2009
Permit #: CB090649 Permit Type: TI
Project Name: INTEGRITY APP: 9482 SF OFFICE Sub Type: INDUST
TO OFFICE
Address: 1921 PALOMAR OAKS WY #300 Lot: 0
Contact Person: MARK Phone: 6199934160
Sewer Dist: CA Water Dist: CA
, h)ó By:
Inspected
Inspected: Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved.
Comments:
EsGil Corporation
In (Partnership with Government for ouilding Safety
DATE: 6/3/09 U APPLICANT
U JURIS.
JURISDICTION: City of Carlsbad u PLAN REVIEWER
U FILE
PLAN CHECK NO.: 09-0649 SET: III
PROJECT ADDRESS: 1921 Palomar Oaks Suite 300
PROJECT NAME: Integrity Applications - TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
Lull The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
Elil The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LIII The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LII The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
1-1 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: Applicant to hand carry the plans directly to the City of Carlsbad this does not
assure a permit will be issued the city may have other corrections.
By: Doug Moody Enclosures:
EsGil Corporation
LIGA El MB [IEJ !:]PC LOG
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
EsGil Corporation
In Partners flip with covernment for Building Safety
DATE: 5/29/09
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 09-0649 SET: II
PROJECT ADDRESS: 1921 Palomar Oaks Suite 300
PROJECT NAME: Integrity Applications - TI
U APPL-IC.ANT
(Jus
U PrANRVIEWER
U FILE
El The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LII The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The'plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Gensler Architects I Ralph Linder
225 Broadway Suite 1600, San Diego, CA 92101
Lii Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Ralph Linder
Date contacted:C (j lo 1 (by: (')Vc)
Mail Telephone Fax' In Person
LI REMARKS:
By: Doug Moody
EsGil Corporation
El GA EMB EEJ L1pc
Telephone #: 619-557-2522
Fax #: 619-557-2520
Enclosures:
5/20/09
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
City of Carlsbad 09-0649
5/29/09
RECHECK CORRECTION LIST
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 09-0649
PROJECT ADDRESS: 1921 Palomar Oaks Suite 300 SET: II
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED:
ESGIL CORPORATION: 5/20/09 5/29/09
REVIEWED BY: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Building Code,
Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy
conservation, noise attenuation and disabled access. This plan review is based on regulations
enforced by the Building Department. You may have other corrections based on laws and
ordinances enforced by the Planning Department, Engineering Department or other
departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
Please make all corrections on the original tracings and submit new complete sets of
prints to:
To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
Please indica1e here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
LJYes UNo
City of Carlsbad 09-0649
5/29/09
Please make all corrections on the original tracings, as requested in the correction list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete.
These corrections are in response to items not fully addressed or as the result of
information provided, the text in bold print indicates the unresolved issue.
Note : When alterations, structural repairs or modifications or additions are made to an existing
building, that building, or portion of the building affected, is required to comply with all of the
requirements for new buildings, per Section 1134B.2. These requirements apply as follows:
A primary entrance to the building and the primary path of travel to the altered
area, must be shown to comply with all accessibility features.
Existing sanitary facilities that serve the remodeled area must be shown to comply
with all accessibility features.
15. It is unclear from the plans if the restrooms servicing the tenant improvement are
disabled accessible, please provide a dimensioned restroom plans showing the restroom
to be accessible compliant. The restrooms as shown are non-compliant, please
provide complete dimensioned plans showing the restrooms fully accessible.
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any Changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes El No U
City of Carlsbad 09-0649
5/29/09
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform
the plan review for your project. If you have any questions regarding these plan review
items, please contact Doug Moody at Esgil Corporation. Thank you.
EsGil Corporation
In Partnership with covernmentforBui(izng Safety
DATE: 4/24/09
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 09-0649 SET: I
PROJECT ADDRESS: 1921 Palomar Oaks Suite 300
PROJECT NAME: Integrity Applications - TI
O P-EIJCNT
UyFS)
U PLAN REVIEWER
U FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
El The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
Lii The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
Lnsl The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
Li The applicant's copy of the check list is enclosed for the jurisdiction to forvvard to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Gensler Architects / Ralph Linder
225 Broadway Suite 1600, San Diego, CA 92101
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Ralph Linder
Date contacted: Lff21[ot (by:c—..
Mail Telephone' Fax/ In Person
LII REMARKS:
By: Doug Moody
EsGil Corporation
EGA [:1 MB EEJ 0Pc
Telephone #: 619-557-2522
Fax #: 619-557-2520
Enclosures:
4/21/09
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
City of Carlsbad 09-0649
4/24/09
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 09-0649
IOCCUPANCY: B
ITYPE OF CONSTRUCTION: Unknown
ALLOWABLE FLOOR AREA:
SPRINKLERS?: YES
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 4/20/09
DATE INITIAL PLAN REVIEW
COMPLETED: 4/24/09
JURISDICTION: City of Carlsbad
USE: Office
ACTUAL AREA: 9482sf
STORIES: 3
HEIGHT:
OCCUPANT LOAD: 148
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 4/21/09
PLAN REVIEWER: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
required prior to the issuance of a building permit.
Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2006 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad 09-0649
4/24/09
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments. -
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
Each sheet of the plans must be signed by the person responsible for their
preparation, even though there are no structural changes. Business and
Professions Code.
2. Please provide a statement on the Title Sheet of the plans to show compliance
with the current Codes. The following are the correct current Codes:
The 2007 edition of the California Building Code (CBC) adopts the 2006
International Building Code (IBC) and the 2007 California Amendments.
The 2007 edition of the California Electrical Code (CEC) adopts the 2005
National Electrical Code (NEC) and the 2007 California Amendments.
The 2007 edition of the California Mechanical Code (CMC) adopts the
2006 Uniform Mechanical Code (UMC) and the 2007 California
Amendments.
The 2007 edition of the California Plumbing Code (CPC) adopts the 2006
Uniform Plumbing Code (UPC) and the 2007 California Amendments.
The 2007 edition of the California Fire Code (CFC) adopts the 2000
Uniform Fire Code (UFC) and the 2007 California Amendments.
The 2005 edition of the California Energy Efficiency Standards.
3. Exit doors shall swing in the direction of exit travel when serving an occupant
load of 50, please revise the door swing of door #355. Section 1008.1.2.
4. Exit signs are required whenever two exits are required. Show all required exit
sign locations. Please revise the plans to show exit signs at doors 385 and
385.2. Section 1011.1.
City of Carlsbad 09-0649
4/24/09
5. Please provide notes on the plans to show the suspended ceilings in Seismic
Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as
follows:
All ceilings shall use a Heavy Duty T-bar grid system.
The width of the perimeter supporting closure angle shall be not less than
2 inches.
In each orthogonal horizontal direction, one end of the ceiling grid shall be
attached to the closure angle.
The other end in each horizontal direction shall have a 3/4" clearance from
the wall and shall rest upon and be free to slide on a closure angle or a
listed assembly.
Ceiling areas over 1,000 ft.2 must have horizontal restraint wires (typically
restraint would consist of four 12 gauge wires splayed 900 to each other
and sloped 450 to the horizontal, spaced 12" o.c.).
Ceiling areas over 2500 ft.2 must have seismic separation joints or full
height partitions that break the ceiling into areas not exceeding 2500 ft.2
Ceilings without rigid bracing must have 2" oversize trim rings for
sprinklers and other ceiling penetrations.
6. Please note in the general wiring notes on the plans "AC Cable is not allowed in
A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City
approval) to one and two family dwellings. Note on plans that an equipment
ground conductor is to be installed in all flexible conduits".
7. Please correct the LTG-1-C forms to show the correct floor area 9482 sq ft and
not 10641 sq ft.
8. Please correct the LTG-1-C part 2 of 4 mandatory automatic controls portion of
the LTG-1 -C forms to show occupancy sensors.
9. Please have the principle designer check the appropriate box(s) and complete
the Statement of Compliance System Acceptance section of the LTG-1 -C part 4
of 4 documents to show occupancy sensors and indicate who will be providing
the required forms to the building inspector.
10. Please clarify the lighting plans to indicate why there is not daylight switching in
rooms 345 and 318?
11. Please review the requirements, revise the plans appropriately and imprint on
the plans the City of Carlsbad Policies and Procedures for Roof Mounted
Equipment to the plans.
12. Please clarify the electrical plans to show the circuits feeding the new HVAC
equipment mounted in the ceiling and on the roof.
13. GFCI protected receptacle outlets are required within 25 feet of all mechanical
equipment (heating, air-conditioning and refrigeration equipment). Please show
on plans. NEC 210.63.
City of Carlsbad 09-0649
4/24/09
Note : When- alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to comply
with all of the requirements for new buildings, per Section 11 34B.2. These requirements
apply as follows:
A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
Existing sanitary facilities that serve the remodeled area must be shown to
comply with all accessibility features.
Show on the site plan the complying disabled accessible path of travel from the
disabled accessible parking spaces to the primary entrance of the tenant space.
Please provide detailed plans of the path of travel, indicate slope and width, any
pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking
stall details etc.
It is unclear from the plans if the restrooms servicing the tenant improvement are
disabled accessible, please provide a dimensioned restroom plans showing the
restroom to be accessible compliant.
Show that the space between two consecutive door openings in a vestibule, which
serves spaces other than a required exit stairway:
Provide ~!48" clear space from any door opening into the vestibule when
door is open 900, per Section 11 33B.2.4.4.
Doors in series shall swing either:
In the same direction.
Away from the space between the doors.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes El No U
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
City of Carlsbad 09-0649
4/24/09
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
City of Carlsbad 09-0649
4/24/09
[DO NOT PAY — THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 09-0649
PREPARED BY: Doug Moody DATE: 4/24/09
BUILDING ADDRESS: 1921 Palomar Oaks Suite 300
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: Unknown
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
TI 9482 34.37 325,896
Air Conditioning
Fire Sprinklers
TOTAL VALUE 325,896
Jurisdiction Code lCD IBY Ordinance I
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review LJ Complete Review
I $1,355.61
I $881.151
LI Structural Only
Repetitive Fee
IIEEII Repeats
LII Other
LI Hourly Hr. t *
EsGil Fee I $759.141
Comments:
Sheet 1 of 1
macvalue doc +
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB090649 DATE 4120109
ADDRESS 1921 PALOMAR OAKS WY
RESIDENTIAL ADDITION- POOL/SPA
MINOR (4179000.00)
TENANT IMPROVEMENTj
RETAINING WALL
COMPLETE OFFICE BUILDING
VILLAGE FAIRE
OTHER
PLANNEF
ENGINEE
DATE 4/20/09
DATE f ) /6~
II\ADMtN\C011TER/PLANMN/ENGINEERlNC APPROVALS
i
15
I.'
Carlsbad Fire Department
Plan Review Requirements Category. TI , INDUST
Date of Report: 06-02-2009
Name: DOWNLING CONSTRUCTION
Address: 5735 KEARY VILLA RD
#103
SAN DIEGO, CA
92123
Reviewed by:
1Ltha IDEPT Copy
Permit #: CB090649
Job Name: INTEGRITY APP.: 9482 SF OFFICE
Job Address: 1921 PALOMAR OAKS WY CBAD St: 300
submitte.dfor-revie.w-is-incon plt -Atthis1ime,--thjs..qffice cannot
-- adequately conduct a review ë-Withthaplicabj codes and/or standards. Please review
carefully all comnentfihed Please resubmit the necessary plans an or speci rcation.. with changes "clouded",
to thiu 010dr-r-eview and approval. -.
Conditions:
Cond: C0N0003451
[NOT MET]
Provide egress plan and occupant load for tenant improvement.
The following or similiar phrase shall be added to the Fire Notes:
"(If required) Complete plans and specifications for fire alarm systems, fire extinguishing
systems, including automatic sprinklers and wet and dry standpipes; halon systems and other special
types of automatic fire protection systems and appurtances thereto shall be submitted to Carlsbad
Fire Department for review and approval PRIOR to installation. (CFC 901.2)"
Indicate in building information if building is sprinklered or not.
Entry: 05/06/2009 By: cwong Action: CO
Cond: C0N0003480
[NOT MET]
In reference to sheets submitted for corrections: Occupant load factors used shall coincide with
Table 1004.1.1. i.e. Conference rooms, lobby areas, break rooms shall use factor of 15.
Specify scale.
Indicate in building information if building is sprinklered or not.
Indicate number of occupants exiting to determine door width.
5. Room 31 C 1 - showroom- add EM lighting.
Entry: 05/26/2009 By: cwong Action: CO
Cond: C0N0003489
[MET]
*
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW.
Entry: 06/02/2009 By: cwong Action: AP
Carlsbad Fire Department
Plan Review Requirements Category: TI , 1NDUST
Date of Report: 05-26-2009 Reviewed by:
Name: DOWNLING CONSTRUCTION
Address: 5735 KEARY VILLA RD
#103
SAN DIEGO, CA
92123
Permit #: CB090649
Job Name: INTEGRITY APP.: 9482 SF OFFICE
Job Address: 1921 PALOMAR OAKS WY CBAD St: 300
..........
INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review
carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval.
Conditions:
Cond: C0N0003451
[NOT MET]
Provide egress plan and occupant load for tenant improvement.
The following or similiar phrase shall be added to the Fire Notes:
"(If required) Complete plans and specifications for fire alarm systems, fire extinguishing
systems, including automatic sprinklers and wet and dry standpipes; halon systems and other special
types of automatic fire protection systems and appurtances thereto shall be submitted to Carlsbad
Fire Department for review and approval PRIOR to installation. (CFC 901.2)"
Indicate in building information if building is sprinklered or not.
Entry: 05/06/2009 By: cwong Action: CO
Cond: C0N0003480
[NOT MET]
In reference to sheets submitted for corrections: Occupant load factors used shall coincide with
Table 1004.1.1. i.e. Conference rooms, lobby areas, break rooms shall use factor of 15. (, C—
r c- Specify scale.
Indicate in building information if building is sprinklered or not.
Indicate number of occupants exiting to determine door width.
Entry: 05/26/2009 05/26/2009 By: cwong Action: CO
Carlsbad Fire Department
Plan Review Requirements Category: TI , INDUST
Date of Report: 05-06-2009 Reviewed by:
Name:
Address:
Permit #: CB090649
DOWNLING CONSTRUCTION
5735 KEARY VILLA RD
#103
SAN DIEGO, CA
92123 LD D1Sp COpy
Job Name: INTEGRITY APP.: 9482 SF OFFICE
Job Address: 1921 PALOMAR OAKS WY CBAD St: 300
INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review
carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval.
Conditions:
Cond: C0N0003451
[NOT MET]
Provide egress plan and occupant load for tenant improvement.
The following or similiar phrase shall be added to the Fire Notes:
"(If required) Complete plans and specifications for fire alarm systems, fire extinguishing
systems, including automatic sprinklers and wet and dry standpipes; halon systems and other special
types of automatic fire protection systems and appurtances thereto shall be submitted to Carlsbad
Fire Department for review and approval PRIOR to installation. (CFC 901.2)"
Indicate in building information if building is sprinklered or not.
Entry: 05/06/2009 By: cwong Action: CO
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
07-07-2009 Plan Check Revision Permit No:PCR09082
Building Inspection Request Line (760) 602-2725
Job Address. 1921 PALOMAR OAKS WY CBAD
Permit Type PCR Status: ISSUED
Parcel No 2120911800 Lot# 0 Applied: 06/29/2009
Valuation: $0.00 Construction Type: NEW Entered By: JMA
Reference #. CB090649 Plan Approved 07/07/2009
PC # Issued: 07/07/2009
Project Title INTEGRITY: PLUMBING REV. TO Inspect Area:
RESTROOMS
Applicant Owner:
RICK LEIN COGNAC PLAZA L L C
C/O PRUDENTIAL REAL ESTATE INVEST
4 EMBARCADERO CTR #2700
SAN FRANCISCO CA 94111
619-339-7425
Plan Check Revision Fee $000
Additional Fees $6000
Total Fees: $6000 Total Payments To Date $6000 Balance Due: $0.00
FINAL APPROVAL
Inspector: Date. Clearance:
NOTICE Please take NOTICE that approval of your project includes the imposition of fees, dedications, reservations, or other exactions hereafter collectively
referred to as fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
BUILDING DEPARTMENT
1635 Faraday Avenue, Carlsbad, CA 92008
Phone: 760-602-7541/ Fax: 760-602-8558
Plan Check Comments /2007 Codes
To: N T- -
From: Steve Borossay
Fax:
- - ao Pages:
Phone: G - T4 Date: 9
7.
Re: PQR &j _A,2. Ic ,qcddress: -zi 'R I r'1 OA czi' (h
+ Please make corrections referred to below and run TWO new prints. If red marks are on
plans as a part of this Plan Check response please return red marked set with the new prints.
+ This is a BUILDING REVIEW ONLY. Comments or approval do not apply to any other City.
department review. For information on the status of approval from other departments please
contact staff @760-602-2717/2718/.2719.
40
V
—cc, sL.0j Q—o
(4& X
"
VL -k-t -e rc cF C b ( 4-- 1
PCR09082 1921 PALOMAR OAKS WY
INTEGRITY PLUMBING REV TO
RESTROOMS
(zq/ôy- Q,pei
c 77-
@
7/y, f, -r! tA -
i (ays (zr
7i7(O-