HomeMy WebLinkAbout1923 CALLE BARCELONA; 136; CB080885; Permit07-01-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No
Building Inspection Request Line (760) 602-2725
CB080885
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
Applicant
1923 CALLE BARCELONA CBAD St 136
Tl Sub Type
2550120400 Lot#
$97,720 00 Construction Type
Reference #
LULU LEMON-2792 SF RETAIL TO
RETAIL
COMM
0
5B
Owner
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Plan Check*
ISSUED
05/14/2008
RMA
07/01/2008
07/01/2008
BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L
L
BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX
C/O DELOITTE TAX LLP
PO BOX 131071
CARLSBAD CA 92013
C/O DELOITTE TAX LLP
PO BOX 131071
CARLSBAD CA 92013
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$587 86 Meter Size
$0 00 Add'l Reel Water Con Fee
$38211 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$2052 PFF (3105540)
, $000 PFF (4305540)
$0 00 License Tax (3104193)
$0 00 License Tax (4304193)
$0 00 - Traffic Impact Fee (3105541)
$0 00 Traffic Impact Fee {4305541)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL ,
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
HMP Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$10400
$12000
$3700
$000
$000
$000
$000
77
$1,251 49
Total Fees $1,251 49 Total Payments To Date $1,251 49 Balance Due $000
Inspector
FINAL APPROVAL
NOTICE Please take NOTICPIhat approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this projf:t NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations lias previously otherwise expired
.Cityof Carlsbad
1635 Faraday Ave Carlsbad CA 92008
760 602 2717 / 2718 / 2719 / 2721
Fax 760-6028558
Building Permit Application
Plan Check No
Est Value
Plan Ck Deposit '
7, /
(Sec. 70315 Binmess and Professions Code Any City or County which require! a permit to coroirua alter, improve demornh or repair any structure pnor to in issuance, also requires the applii
ricensed bunuant to (tie provision! of tfie Contrattors Ucensc Law {Qiuter 9 (ominendimi with Section 7000 of Division J ol the Business and Proftsiioiu Code} or tfui he rs exempt therefromSection 70)1 S by anr appbcuil for i permit inject, the apptiunt to i ovil penalry of i»t more than fm hundred dollan {$SOO})
icant for ludi permit To hie a iigned Statement thVhe D
rom, and (he basis for the alleged exemption Any violation of
Workers Compensation Declaration I hereby affirm under penalty of perjury one of the
I I I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued
j^ I have and will maintain workers compensation as required by Section 3700 of the Labor Code for the performance ofthe work for whichttis permit isissued My workers compensation insurance earner and policy
number are Insurance Co £^flQ VH)./1>}l_ £^S PolcyNo <^?^5^^;SC Expiration Da(e /^~ 01 -<J^asection need not be completed if Ihe permit is for one hundred dollars ($100) or less
Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of
California. WARNING Failure to secure workers compeaBationc.jBB.wge is unlawful andshallsublectanemployertocrimlnalpenalUesandcivilfinesuptoonehundredthousanddollarsf&IOOOOO) in
addition to the cost of compensation damages as pro^ffid fy^nSectio) 3706 gf^gj^bor code interest and attorney's fees
>£T CONTRACTOR SIGNATURE *f*V^ — PATE ^*» / ~10 9>
/ hereby affirm (ftaf / am exempt from Contractor's License Law for the following reason
[""] I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor's
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale If however the building or improvement rs sold within one year of complelion the owner-builder will have the burden of proving that he did not build or improve for Ihe purpose of sale)
Kl as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of
property who builds or improves thereon and contracts fot such projects with contractors} licensed pursuant to the Contractor's License Law)
I 1 I am exempt under Section Business and Professions Code for this reason ^^ ^^
1 I personally plan to provide! the major labor and malenals for construction of the proposed properly improvement \__\ Yes [ JNo
2.1 (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work)
•^PROPERTY OWNER SIGNATURE DATE
ffCOOS L70S CO® O°CBS80®@G3'i70&ll OQBGllSOO® PSG3(aOT?8
Isttio applicant or future building occupant required to submit a business
Presley Tanner Hazardous Substance Account Act? I I Yes JflNo
Is Ihe applicant or future buiding occupant required to obtain a permit fromthe air pdluton control district or
ts the facility to be constructed within 1 000 feet of the outer boundary of a school site? QYes
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
acutely hazardous materials registration form 01 risk management and prevention p
o
y management district? I iVes
gram under Sections 25505 25533 or 25534 of the
S THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code)
Lentter's Name Lender's Address
iKttrlythatl have read ttie application and state that tlK above inform^onrs correct and ttiatte
OSHA. An OSHA permrt is requn^ for excavations rjwSVcleep and d^
EXPIRATION Every pemut issued by the Bulking Official under the prowswisoftrBsCocteshalexprety
180 days torn the date of such peimfl or if tr^bjjjraL^j^woritau^^
DATE^APPLICANTS SIGNATURE
City of Carlsbad
p)E<3Efl'
ITuCuEiRD
Final Building Inspection
Depf Building Engineering Planning CMWD St Lite <Fj?e?
Plan Check*
Permit #CB080885
Project Name LULU LEMON-2792 SF RETAIL TO
RETAIL
Address 1923 CALLE BARCELONA #136
Contact Person ROB Phone 6024187839
Sewer Dist LC Water Dist O
Date 09/11/2008
Permit Type Tl
Sub Type COMM
Lot
Inspected /)
By /> k
Inspected
By
Inspected
By
Comments
* Date /
's*»~"l Inspected 7/1
/ /Date
Inspected
Date
Inspected
n Qff Approved r1
Approved
Approved
Disapproved
Disapproved
Disapproved
Inspection List
Permit* CB080885 Type Tl COMM
Date Inspection Item
09/11/2008 89 Final Combo
09/11/200889 Final Combo
08/28/2008 23 Gas/Test/Repairs
08/18/2008 18 Exterior Lath/Drywall
08/15/2008 14 Frame/Steel/Boltmg/Weldin
08/06/200817 Interior Lath/Drywall
08/04/2008 14 Frame/Steel/Bolting/Weldm
07/31/2008 84 Rough Combo
07/28/2008 34 Rough Electric
07/28/2008 34 Rough Electric
07/21/2008 14 Frame/Steel/Boltmg/Weldin
07/21/200817 Interior Lath/Drywall
07/21/2008 24 Rough/Topout
07/21/2008 34 Rough Electric
07/11/2008 21 Underground/Under Floor
07/03/2008 44 Rough/Ducts/Dampers
Inspector
PY
TP
PY
PD
PY
PY
MC
PY
PY
PD
PD
PD
PD
PY
PY
Act
AP
Rl
AP
WC
PA
PA
PA
CO
PA
PA
PA
PA
PA
PA
AP
AP
LULU LEMON-2792 SF RETAIL TO
RETAIL
Comments. _
FIRE IS OK
@ AWNING
LID @ MAIN ROOM
CEILING
NO ACCESS, NO SUPER
EMR
EMR
WALLS
WALLS
WALLS
WALLS
Monday September 15 2008 Page 1 of 1
City of Carlsbad Bldg Inspection Request
Inspector Assignment PY
For 09/11/2008
Permit* CB080885
Title LULU LEMON-2792 SF RETAIL TO
Description RETAIL
Type Tl Sub Type COMM
Job Address 1923 CALLE BARCELONA
Suite 136 Lot 0
Location Inspector
OWNER BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L
Owner
Remarks FIRE IS OK
Phone 6024187839
Total Time Requested By ROB
Entered By JANEAN
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
IOR~A\VN1NG
Comments
^PCR08075— PENDING fcUI-UI-FMON -ADD TXTO
Insoection History
Date
08/28/2008
08/18/2008
08/15/2008
08/06/2008
08/04/2008
07/31/2008
07/28/2008
07/28/2008
07/21/2008
07/21/2008
07/21/2008
07/21/2008
07/11/2008
Description
23
18
14
17
14
84
34
34
14
17
24
34
21
Gas/Test/Repairs
Exterior Lath/Drywall
Frame/Steel/Bolting/Welding
Interior Lath/Drywall
Frame/Steel/Bolting/Welding
Rough Combo
Rough Electric
Rough Electric
Frame/Steel/Bolting/Welding
Interior Lath/Drywall
Rough/Topout
Rough Electric
Underground/Under Floor
Act
AP
we
PA
PA
PA
CO
PA
PA
PA
PA
PA
PA
AP
Insp
TP
PY
PD
PY
PY
MC
PY
PY
PD
PD
PD
PD
PY
@ AWNING
LID @ MAIN ROOM
CEILING
NO ACCESS, NO SUPER
EMR
WALLS
v' City of Carlsbad Bldg Inspection Request
For 08/28/2008
Permit* CB080885
Title LULU LEMON-2792 SF RETAIL TO
Description RETAIL
Inspector Assignment PY
Type Tl Sub Type COMM
Job Address 1923 CALLE BARCELONA
Suite 136 Lot 0
Location
Phone 6024187839
Inspector
APPLICANT BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L
Owner
Remarks GMR -GAUGE ON FOR TEST
Total Time Requested By ROB
Entered By CHRISTINE
CD Description
23 Gas/Test/Repairs
Act Comments
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
PCR08075 PENDING LULULEMON ADD EXTERIOR AWNING
Inspection History
Date Description Act
08/18/2008 18 Exterior Lath/Drywall WC
08/15/2008 14 Frame/Steel/Bolting/Weldmg PA
08/06/2008 17 Interior Lath/Drywall PA
08/04/2008 14 Frame/Steel/Bolting/Welding PA
07/31/2008 84 Rough Combo CO
07/28/2008 34 Rough Electric PA
07/28/2008 34 Rough Electric PA
07/21/2008 14 Frame/Steel/Bolting/Welding PA
07/21/2008 17 Interior Lath/Drywall PA
07/21/2008 24 RoughfTopOUt PA
07/21/2008 34 Rough Electric PA
07/11/2008 21 Underground/Under Floor AP
07/03/2008 44 Rough/Ducts/Dampers AP
Insp Comments
PY
PD @ AWNING
PY LID @ MAIN ROOM
CEILING
NO ACCESS, NO SUPER
EMR
PY
MC
PY
PY
PD
PD
PD
PD
PY
PY
WALLS
CITY OF CARLSBAD
BUILDING DEPARTMENT
DATE
NOTICE
(760) 602-2700
1635 FARADAY AVENUE
LOCATION
PERMIT NO
x~
1 p
—6
FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? ' YES
FOR FURTb'fitylNRORMATION, CONTACT
PHONE
BUILDING INSPECTOR CODE ENFORCEMENT OFFICER
EsGil Corporation
In (PartnenHip with government for (Bmhfing Safety
DATE June 19, 2O08
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 08-0885 SET II
i
PROJECT ADDRESS 1923 Calle Barcelona, Building 3, Suite #136
PROJECT NAME Lululemon Athletica TI
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
2<] Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Dan Schultz Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Bryan Zuppiger Enclosures
Esgil Corporation
D GA D MB D EJ D PC O6/12/2008
trnsmtl dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
EsGil Corporation
In Partnership -with government for (RmCcfing Safety
DATE May 27, 20O8
JURISDICTION Carlsbad Q~PLAN REVIEWER
a FILE
PLAN CHECK NO O8-0885 SET I
PROJECT ADDRESS 1923 Calle Barcelona, Building 3, Suite #136
PROJECT NAME Lululemon Athletica TI
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X3 The applicant's copy of the check list has been sent to
Dan Schultz
1422 South Allec?, #C?
Anaheim, CA 92805
Esgil Corporation staff did not advise the applicant that the plan check has been completed
X] Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted JBan/Schultz Telephone # 949 770 5752 x #102
Date contacted ^V^fbyV^ ) Fax # 949 770 9917
Mail Telephone ^X^Fax v In Person
REMARKS
By Bryan Zuppiger Enclosures
Esgil Corporation
D GA D MB D EJ D PC O5/19/2OO8
trnsmtl dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576
Carlsbad 08-0885
May 27, 2OO8
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 08-O885
OCCUPANCY M
TYPE OF CONSTRUCTION VN?
SPRINKLERS'? yes
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED May 27, 2008
JURISDICTION Carlsbad
USE clothing store
ACTUAL AREA 2792 ft2
OCCUPANT LOAD 93
DATE PLANS RECEIVED BY
ESGIL CORPORATION 05/19/2008
PLAN REVIEWER Bryan Zuppiger
This plan review is limited to the technical requirements contained in the International Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review is
based on regulations enforced by the Building Department You may have other corrections based on
laws and ordinances enforced by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to the
issuance of a building permit
Code sections cited are based on the 2007 CBC that adopts the 2006 IBC
The following items listed need clarification, modification or change All items must be satisfied before
the plans will be in conformance with the cited codes and regulations Per IBC Section 105 4 of the
2006 International Building Code, the approval of the plans does not permit the violation of any state,
county or city law
To speed up the recheck process, please note on this list (or a copy) where each correction
item has been addressed, i e., plan sheet number, specification section, etc Be sure to
enclose the marked up list when you submit the revised plans.
Carlsbad 08-O885
May 27; 2008
• PLANS
1 Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
2 Why is Detail 1B/A501 as referenced on Sheet A101 omitted on Sheet A501 ?
3 Provide the names, addresses and telephone numbers of the owner on the Title Sheet CBC
Section 106 1 1
4 Please revise the Building Code Data Legend, Section numbers and Notes on the Title Sheet
on the plans to match the 2006 IBC, as adopted by the State of California Include the
following code information for each building proposed
<> For Mixed Occupancy Buildings, state whether the "non-separated" or "separated" option
was chosen from IBC Section 508 3
• Type of Construction , please state all work will comply with VB,
5 Indicate the use of all spaces adjacent to the area being remodeled or improved
6 When alterations, structural repairs or modifications or additions are made to an existing
building, that building, or portion of the building affected, is required to comply with all of the
requirements for new buildings, per CBC Section 1134B 2 These requirements apply as follows
a) The area of specific alteration, repair or addition must comply as "new" construction
b) A primary entrance to the building and the primary path of travel to the altered area.
must be shown to comply with all accessibility features
c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all
accessibility features
7 Show on the site plan the complying disabled accessible path of travel from the disabled
accessible parking spaces to the primary entrance of the tenant space Please provide detailed
plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks,
handrails, provide dimensioned parking stall details etc
Carlsbad 08-O885
May 27, 2008
8 Please revise the plans to show a disabled accessible transaction counter located in the same
area as the counter for the general public and provide a section of counter that is at least 36"
long and no more than 28" to 34" high CBC Section 1122B 4
9 Doors in the room shall not swing into the clear floor space required for any fixture Maintain the
required clearances at the lavatory/water closet without the entry door swinging into those areas
CBC Section 1115B322
a) The clear space in front of the water closet measures 60" wide by 48" in front CBC
Section 1115B41 2
The person responsible for their preparation must sign all final sheets of plans (California
Business and Professions Code)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contact Bryan Zuppiger at Esgil Corporation Thank you
Carlsbad O8-O885
May 27, 2OO8
JURISDICTION Carlsbad
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO O8-O885
PREPARED BY Bryan Zuppiger DATE May 27, 2008
BUILDING ADDRESS 1923 Calle Barcelona, Building 3, Suite #136
BUILDING OCCUPANCY M TYPE OF CONSTRUCTION VN
BUILDING
PORTION
ti
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
2793
cb
RIHn Pprmif Fpp hv OrHmanrp ^ I
Valuation
Multiplier
3437
By Ordinance
Reg
Mod
VALUE ($)
95,995
95,995
$579 45
Plan Check Fee by Ordinance
Type of Review
I Repetitive FeeRepeats
Complete Review
D Other
r—I Hourly
Structural Only
Hour
Esgil Plan Review Fee
Comments
$376 64
$324 49
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB080885 DATE 5/14/08
ADDRESS 1923 Calle Barcelona
RESIDENTIAL ADDITION-
MINOR (<17,000.00)
RETAINING WALL
VILLAGE FAIRE
POOL/SPA
TENANT IMPROVEMENT
COMPLETE OFFICE BUILDING
OTHER
PLANNER Deborah Milam DATE 6/5/08
DATE <^
ii umii\\iiiii\n.ii/i'i..\\\iNi,/E\i;i\i;i;iiiv, AiTi
Carlsbad Fire Department
Plan Review Requirements Category TI , COMM
Date of Report 05-30-2008 Reviewed by O^jQ/Tf K
Name
Address
BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L
C/O DELOITTE TAX LLP
PO BOX 131071
CARLSBAD CA
92013
Permit # CB080885
Job Name LULU LEMON-2792 SF RETAIL TO
Job Address 1923 CALLE BARCELONA CBAD St 1 36
B*-DG.DEPTCOPY
^val
ftpfKMtifthMEeassa^^ review
gssat^^ams^H^gFgp^crftc'HtTuiiij,11 wiulwhtinges "clouded",
'Conditions:
Cond CON0002811
[MET]
** APPROVED
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS. FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Entrv 05/30/2008 Bv cwonc Action AP
05-07-2009
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR08075
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Reference #
PC#
Project Title
Applicant
ROB PHELPS
602-418-7839
1923 CALLE BARCELONA CBADSt 136
PCR
2550120400 Lot*
$0 00 Construction Type
CB080885
LULULEMON ADD EXTERIOR
AWNING
0
NEW
Statu
Applied
Entered By
Plan Approved
Issued
Inspect Area
JEXPIBED-
WT
JMA
Owner
BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L
C/0 DELOITTE TAX LLP
PO BOX 131071
CARLSBAD CA 92013
Plan Check Revision Fee
Additional Fees
$12000
$000
Total Fees $120 00 Total Payments To Date $0 00 Balance Due $12000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
Plan Check Revision No
Project Address
-Contact fefr ffiJ*
-Address dAPl^"^ OA
-7S"
Building Department
Original Plan Check No
Date
Ph
Business at this address LujJ j_ L^SflAfcf^J
APN
General Scope of Work ____
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised
n Plans G Calculations G Soi's D Energy Q Other __
2
Describe revisions in detail
feyrt JUoKl/WL @ fcfxtreV
5 Does this revision, in any way, alter the exterior of the project"?
O Does this revision add ANY new floor area(s)"? /"
7 Does this revision affectany fire related issues?
8 Is this a complete set trranreplaoel the original permitted set?
3
List page(s) where
each revision is
shown
& CO)
_k io\
4.Z01
jL^y2)
5 I
^ 2-
KL Yes D N
D Yes 0 N
D Yes IS, N
D Yes 01 N
4
List revised sheets
that replace
existing sheets
0
lo
0
lo
^Signature t^ML
1635 Faraday Avenue, Carlsbad, CA 92008 Phone 760-602-2717 / 2718 / 2719 / 7541 Fax 760-602-8558
EsGiB Corporation
In (Partnership with government for (BuiCd ing Safety
DATE July 25, 2008
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 08-0885 REV (PCR08-75) SET I
PROJECT ADDRESS 1923 Calle Barcelona, Building 3, Suite #136
PROJECT NAME Lululemon Athletica Awning
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
X3 The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Dan Schultz
1422 South Allec?, #C?
Anaheim, CA 92805
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Dan Schultz (\ M) Telephone # 949 770 5752 x #102
Date contacted T/Z_5/o9-(by l^ ) Fax # 949 770 9917
Mail Telephone "^ Fax^ In Person
REMARKS
By Bryan Zuppiger Enclosures
Esgil Corporation
D GA D MB D EJ D PC 07/21/2008
trnsmtl dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 O Fax (858) 560-1576
Qarlsbad O8-0885 REV (PCR08-75)
July'25, 2O08
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO O8-O885 REV (PCRO8-75) JURISDICTION Carlsbad
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION ESGIL CORPORATION 07/21/2008
DATE INITIAL PLAN REVIEW PLAN REVIEWER Bryan Zuppiger
COMPLETED July 25, 2008
This plan review is limited to the technical requirements contained in the International Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review is
based on regulations enforced by the Building Department You may have other corrections based on
laws and ordinances enforced by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to the
issuance of a building permit
Code sections cited are based on the 2007 CBC that adopts the 2006 IBC
The following items listed need clarification, modification or change All items must be satisfied before
the plans will be in conformance with the cited codes and regulations Per IBC Section 105 4 of the
2006 International Building Code, the approval of the plans does not permit the violation of any state,
county or city law
To speed up the recheck process, please note on this list for a copy) where each correction
item has been addressed, i e . plan sheet number, specification section, etc Be sure to
enclose the marked up list when you submit the revised plans
Carlsbad O8-0885 REV (PCRO8-75)
July 25, 2008
• PLANS
1 Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
2 Please submit the supporting calculations
The person responsible for their preparation must sign all final sheets of plans (California
Business and Professions Code)
Final structural plans, specifications and calculations must be signed and sealed by the
engineer or architect licensed by the State of California who is responsible for their
preparation Please specify the expiration date of license (California Business and Professions
Code)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contaetBryan Zuppiger at Esgil Corporation Thank you
Carlsbad O8-0885 REV (PCRO8-75)
July 25, 20O8
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO 08-O885 REV (PCR08-75)
PREPARED BY Bryan Zuppiger DATE July 25, 2008
BUILDING ADDRESS 1923 Calle Barcelona, Building 3, Suite #136
BUILDING OCCUPANCY M TYPE OF CONSTRUCTION VN
BUILDING
PORTION
ti
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
cb
Valuation
Multiplier
By Ordinance
• -v 1
Reg
Mod
VALUE ($)
Plan Check Fee by Ordinance
Type of Review H Complete Review
$12000
fj Structural Only
CH-Repetitive Fee
~^~| Repeats
Other
Hourly
Esgil Plan Review Fee
Hour*
$9600
* Based on hourly rate
Comments
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER O9'75
"
DATE
ADDRESS
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $17,000.00)
OTHER
PLANNER
ENGINE
DATE
DATE
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
Docs/Misforms/Piannmg Engineering Approvals
* * *o <D o>S 6 Sc c cIII
3 n n
D
D
D
D
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No PCR 08-75 Address 1923 Calle Barcelona
Phone (760) 602- 4619Planner Deborah Milam
APN 255-012-04
Type of Project & Use JJ Net Project Density
Zoning P-C General Plan R Facilities Management Zone 23
CFD (in/out) #_Date of participation Remaining net dev acres
DU/AC
Circle One (For non-residential development Type of land used created by this
permit )
Legend Item Complete
Environmental Review Required
DATE OF COMPLETION
I I Item Incomplete - Needs your action
YES D NO D TYPE
Compliance with conditions of approval7 If not, state conditions which require action
Conditions of Approval
Discretionary Action Required YES D NO D TYPE
APPROVAL/RESO NO DATE
PROJECT NO
OTHER RELATED CASES
Compliance with conditions or approval? If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone?YES EH NO Q
CA Coastal Commission Authority? YES Q NO d
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite
103, San Diego, CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Habitat Management Plan
Data Entry Completed? YES D NO Q
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat
Type impacted/taken, UPDATE')
Inclusionary Housing Fee required YES Q NO I I
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
Data Entry Completed? YES D NO D
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing
Y/N, Enter Fee, UPDATE')
H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08
Site Plan
D Provide a fully dimensional site plan drawn to scale Show North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes) Provide legal description of property and assessor's parcel number
Policy 44 - Neighborhood Architectural Design Guidelines
D D 1 Applicability YES D NO D
n D 2 Project complies YES D NCQ
D D
D
Zoning
1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope
Required
Required
Required
Required
Required
2 Accessory structure setbacks
Front Required
Interior Side Required
Street Side Required
Rear Required
Structure separation Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
3 Lot Coverage Required Shown
4 Height
5 Parking
Required Shown
Spaces Required Shown
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments Signs cannot be approved as part of this permit Please indicate that
they are not a part of this permit and that a separate sign permit will be processed for them
Application is attached and can be submitted to the Planning Department This permit can be
processed before the signs are applied for
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08
MESBJ ENGINEERING
STRUCTURAL CONSULTING ,|j| (to. 3830
PROJECT; CHANGE TO BUILDING #3. FORUM AT CARLSBAD
ROOF LOADS (FLAT)
ROOFING 3 0 (NO GRAVEL)PLYWOOD 18
RAFTERS 30
CLG + INSULATION 3 0
SPRINKLER 2 0
MISC 22
DEAD LOAD LIVE LOAD
150 PSF 200 PSF
TOTAL LOAD
35 0 PSF
WALL (EXT) 160 PSF BEAMS #1 JOIST & BLOCKING #2 OR #1
WALL(INT) 100PSF POSTS #1 STUDS & PLATES #2 OR #1 U ON
ALLCONCREIETOBEAMIN OF 3000 PSIAI 28 DAYS STRENGTH (SEE PUNS HOft SPECIAL INSPECTION REQUJREMbNTS)
Ss = l 225, Fa-1 02 Sds= 817
SOIL PRESSURE 2500 psf @ IS BELOW GRADF
WIND CBC2007 EXP B.70MPH, 12 PSF
BY GEOCONINC
ALL MASONRY TO BF, fm= If 00 psi U 0 N (SEE PLANS FOR SPECIAL INSPECTION REQU1REMEN fS, PRISM TESTS ARE
REQUIRED WHEN SPECIAL INSPECTION IS SPECIFIED)
ALL GLUE-LAMINATED BEAMS ARE 2400F-V4 (SIMPLE SPAN), AND 2400F-V8 (CANTILtVCR SPAN)
BALCONY UVE LOAD N/A
EXIT/CORRIDOR LIVE LOAD. N/A
THF MESR1 ENGINEERING
THESE CALCULATIONS ARE ONLY FOR THE ITEMS INCLUDED HEREIN. SPECIFIED BY THE CL1FNT AND DO NOT
IMPLY APPROVAL OF ANY OTHER PART OF THE STRUCTTIRF BY THIS OFFICE
JOB NO Qgi9 DATE.DESIGNED BY KM CHECKED BY.
coo®9NIH33NI9N3 IHS3R
« 4 .1. I
8£i9CiZ8S8 XVd IS 80 800S/OC/»0