Loading...
HomeMy WebLinkAbout1923 CALLE BARCELONA; 141; CB111055; Permit07-08-2011 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB111055 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 1923 CALLE BARCELONA CBAD St: 141 Tl Sub Type: 2550120400 Lot#: $64,552.00 Construction Type: Reference #: NICHOLE MILLER: 1,739 SF RETAI TO RETAIL COMM 0 NEW Applicant: MARGARET WHITLOCK 1711 28THST SAN DIEGO CA 92102 619-206-8328 Status: ISSUED Applied: 05/18/2011 Entered By: JMA Plan Approved: 07/08/2011 Issued: 07/08/2011 Inspect Area: Plan Check#: Owner: FOURTH QUARTER PROPERTIES XXX L L C C/O THOMAS TROPEA 45 ANSLEY DR NEWNAN GA 30263 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $486.68 Meter Size $0.00 Add'l Reel. Water Con. Fee $316.34 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $13.56 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 tScense Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees $1.00 HMPFee $250.00 TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $1,111.58 Total Fees:$1,111.58 Total Payments To Date:$1,111.58 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717/2718/2719 Fax: 760-602-8558 www.carlsbadca.gov Plan Check No. Est. Value Plan Ck. Deposit Date 11 SWPPP JOB ADDRESS S U IT£#/SPACE#/ U N IT# # BATHROOMS 1 TENANT BUSINESS NA!CONSTR. TYPE I OCC. GROUPCT/PROJECT ## OF UNITS I # BEDROOMS DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending wilKSection 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant JOT a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). •" Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: LJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this perm it is issued. (eh have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation, insurance carrier and policy number are: Insurance Co.f&<if<*&f-' /a^-c-ff-g. j^J^r Policy No.iAJC-OPf*?^ ^(f^Cf Expiration Date (0I&I )1— This section need not be completed if the permit is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure waders' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.0DO), in addition to the cost of compensation, dam/g* as provided for in Sec)jnn-J706 of the Labor code, interest and attorney's fees. & CONTRACTOR SIGNATURE |~| £JTOENT DATE ' f I hereby affirm that I am exempt from CoijtyKtor's License Law lor the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: D No1 . 1 personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes 2. 1 (have / have not) signed an application for a building permit for the proposed work. 3. 1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4. 1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5. 1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ^PROPERTY OWNER SIGNATURE OAGENT DATE te the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? OYes TjQto Is the applicant or future building occupant required to obtain a permit from me air pollution control district or air quality management district? Q Yes JfNo Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes WNo IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ' I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relatingto building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSH A: An OSHA permit is required for excavations over 5'G" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within City of Carlsbad Bldg Inspection Request For: 08/18/2011 Permit* CB111055 Title: NICHOLE MILLER: 1,739 SF RETAI Description: TO RETAIL Inspector Assignment: TP Sub Type: COMM 1923 CALLE BARCELONA 141 Lot: 0 Type: Tl Job Address: Suite: Location: OWNER FOURTH QUARTER PROPERTIES XXX L L C Owner: Remarks: Phone: Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: TIM Entered By: CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Original PC# Inspection History Date Description Act Insp Comments 08/16/2011 89 Final Combo CO TP City of Carlsbad final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check*: Permit#: CB111055 Project Name: NICHOLE MILLER: 1,739 SF RETAI TO RETAIL Address: 1923 CALLE BARCELONA #141 Phone: Date: 08/15/2011 Permit Type: Tl Sub Type: COMM Lot: Contact Person: Sewer Dist:LC Water Dist: 0 Inspected Bv: Inspected By: Inspected By: Date . Inspected: Date . Inspected: Date .Inspected: Approved: Approved: Approved: Disapproved: Disapproved: Disapproved: Comments: EsGil Corporation In {Partnership with government for Quitting Safety DATE: 7/5/11 O APPLICANT a JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 11-1055 SET: II PROJECT ADDRESS: 1923 Calle Barcelona Suite 141 PROJECT NAME: Nicole Miller Dress Shop - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person XI REMARKS: Applicant to hand carry the plans directly to the City of Carlsbad this does not assure a permit will be issued the city may have other corrections. By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 6/28/11 9320 Chesapeake Drive, Suite 208 > San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership -with government for (BuiCtRng Safety DATE: 06/08/2011 ' ' a APPLICANT Q JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 111186 SET: I PROJECT ADDRESS: 1923 Calle Barcelona, Ste. 141 PROJECT NAME: Storefront Modification The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation,staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person XI REMARKS: All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code. 5536.1). By: Aaron Goodman Enclosures: EsGii Corporation D GA D EJ D PC 06/02/2011 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 111 186 06/08/2011 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 111186 PREPARED BY: Aaron Goodman DATE: 06/08/2011 BUILDING ADDRESS: 1923 Calle Barcelona, Ste. 141 Set I BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: V-B Sprinklered BUILDING PORTION Storefront Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) cb Valuation Multiplier By Ordinance Reg. Mod. VALUE ($) 50,000 50,000 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: Repetitive Fee Repeats Complete Review D Other r-j Hourly EsGil Fee Structural Only Hr. @* $418.43 $271.98 $234.32 Comments: Sheet 1 of 1 macvalue.doc + EsGil Corporation In (Partnership with government for Quitting Safety DATE: 6/1/11 a AEEUSANT a (JURIS. J> JURISDICTION: City of Carlsbad a PLAN REVIEWER Q FILE PLAN CHECK NO.: 11-1055 SET. I PROJECT ADDRESS: 1923 Calle Barcelona Suite 141 PROJECT NAME: Nicole Miller Dress Shop - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 2<J- The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. A] The applicant's copy of the check list has been sent to: Architectural Concepts Inc. / Margit Whitlock 1711 28th Street, San Diego, CA 92102 Esgil Corporation staff did not advise the applicant that the plan check has been completed. 2<J Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Margit Whitlock Telephone #: 619-206-0328 (v'H.wor Date contacted: u>( | Ml (by: ^L) Email: margitwhitlock@gmail.com Fax #: Mail v Telephone Fax In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporationn GA n EJ n PC 5/23/11 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576 City of Carlsbad 6/1/11 11-1055 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 11-1055 OCCUPANCY: M TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: YS REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 5/18/11 DATE INITIAL PLAN REVIEW COMPLETED: 6/1/11 JURISDICTION: City of Carlsbad USE: Retail ACTUAL AREA: 1739sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 54 DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/23/11 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 11-1O55 6/1/11 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Please correct the scale on the plan (plans indicate 3/ie and appear Y*), Sec.107.2. 2. Please clarify the plans will the storefront be altered as indicated in note 2 on sheetAH? 3. Please revise the occupant load the correct occupant is 54 to this is a grade level M occupancy and the floor area should be divided by an occupant load factor of 30sf gross and not 60sf. 4. Exit doors shall swing in the direction of exit travel when serving an occupant load of 50 or more persons. Section 1008.1.2. 5. Please provide the ICC listing and installation of the new suspended gypsum ceiling. Section 107.2. 6. Please provide complete electrical plans. 7. Please provide panel schedules, indicate new and existing loads. 8. Please indicate on the plans the location of the electrical panel and detail the required working clearance. 9. Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 10. Please provide a lighting fixtures schedule. City of Carlsbad 11-1055 6/1/11 11. Please provide the required LTG forms. 12. Please have the document author and the principle designer of the LTG-1-C form sign the imprinted document. 13. Provide automatic shut-off controls for lighting as per Title 24, Part Q, Section 131(d). (5,000 square foot exemption has been eliminated-AB 970 energy design change). 14. Please complete the LTG-1-C part 3 of 4 mandatory automatic controls portion of the LTG-1-C forms. 15. Please have the principle designer check the appropriate box(s) and complete the Statement of Compliance System Acceptance section of the LTG-1-C part 4 of 4 documents. 16. Please provide the required LTG-5C form for the track lighting. 17. Please indicate if the mechanical system will be altered. If so please provide complete plans. Please provide the required MECH forms to show energy compliance. The MECH forms shall be signed and imprinted to the plans. 18. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing ductwork; please note or show mechanical ventilation will be provided capable of supplying the minimum rate of outside air required per minute per occupant as shown in Table 4-1 of the UMC. 19. Please revise the plans to show >1 fitting room or dressing room for the customers shall be provided as follows: i) Entry doors shall provide: a) >32" clearance. b) >18" strike edge. ii) The room dimension shall be >60" in width and length and no door shall encroach into the required space. iii) Show a wardrobe hook mounted <_48" from the floor, iv) Show a 24" x 48" bench: a) Fixed along the wall at the 48" dimension: b) Mounted >17" but < 19". 20. Please clarify the door schedule to show the new sliding doors to be provided with hand activated door opening hardware for the sliding door to be designed to provide passage without requiring the ability to grasp the opening hardware. City of Carlsbad 11-1055 6/1/11 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive/Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 11-1055 6/1/11 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 11-1055 PREPARED BY: Doug Moody DATE: 6/1/11 BUILDING ADDRESS: 1923 Calle Barcelona Suite 141 BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VB BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft.) 1739 cb Valuation Multiplier 37.12 By Ordinance Reg. Mod. VALUE ($) 64,552 64,552 $486.68 Plan Check Fee by Ordinance Type of Review: _TJ] Repetitive FeeRepeats Complete Review D Other i—| Hourly EsGil Fee Structural Only Hr. @ * $316.34 $272.54 Comments: Sheet 1 of 1 macvalue.doc + PLANNING/ENGINEERING APPROVALS PERMIT NUMBER C& H- \0155 DATE £^23/1n ADDRESS RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$20,000.00) JFEflANT IMPROVEMENT ^ REAL-" CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING PLANNER DATE ENGIN DATE Q:\CED\LandDev\Correspondence\Ontiveros\for planchecfcingVBUILDING PLANCHECK CKLIST FORM - PLANNING ENGINERING APPROVALS.docx PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB111055 DATE 5/19/11 ADDRESS 1923 CALLE BARCELONA #141 RESIDENTIAL ADDITION- MINOR (< 17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING SOLAR PANELS OTHER PLANNER ENGINEER DATE DATE H:\ADMIN\COIINTER/PUNNING/ENGINEERINGAPPIIOVALS RECOMMENDED FOR APPROVAL Page: 1 of 1 Daryl K. James & Associates, Inc. Checked by: Susan Guzzetta Date: July 3. 2011 fiLDG. DEPT COPY APPLICANT: Stefanie Lyons JURISDICTION: Carlsbad Fire Department PROJECT NAME: Nicole Miller PROJECT ADDRESS: 1923 Calle Barcelona #141 Carlsbad PROJECT DESCRIPTION: CB111055 T.I. of retail space/ interior partitions INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. • The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. • To expedite the recheck process, please note on this document (or copy) how and where each correction item listed below has been addressed (sheet number, note number, detail number, legend number, etc.). Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates. • PLEASE SEND OR DELIVER REVISED PLANS WITH BUILDING DEPT. COMMENTS DIRECTLY TO: SUSAN GUZZETTA 5121 COSTA RUSTICO SAN CLEMENTE, CA 92673 1 Please direct any questions regarding this review directly to: Susan Guzzetta at 949-573-1558 or stguzzetta@gmail.com AO.O V Under "Applicable Code" item #1, the 2007 CBC is referenced. The correct edition is the 2010. Updated year for CBC on sheet AO.O V Provide note on plan that ceiling and floor finishes will meet California Building Code Section 803. Added note #8 on sheet AO.O V Under deferred submittals add "Fire Sprinklers" Fire Sprinklers added on sheet AO.O A0.4 Indicate fire extinguisher locations Added to sheet A0.4 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 07-07-2011 Reviewed by: Name: MARGARET WHITLOCK Address: 171128THST SAN DIEGO CA 92102 Permit #: CB111055 Job Name: NICHOLE MILLER: 1,739 SF RETAI Job Address: 1923 CALLE BARCELONA CBAD St: 141 VVVVVVVVVVVft/VVVVVVVVV^VA/MVA/VVVJ^/T^\A^\£VA.iA£Vl\? V/WW W VW V WWV W V vX/W VW VW WVW WWWX/VA/.W WWVAW jjjjfgOpafflff^^ ^ Conditions: Cond: CON0004747 [MET] ** CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 07/06/2011 By: GR Action: AP SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE Business Name Sj\.C<>VC- Business Contact/ <=^~<JL*.^- <• Micitp ^f v Telephone # Project Address \\\ State .-.*, Mailing Address City y WxV State Zip Code Plan File# Project Contest elephone # The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circ ed, applicant must contact the Fire Prqtection^gency with jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): ISbfJi Occupancy Rating: y? 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives 2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards 3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These. 4. Flammable Solids 8. Unstable Reactives 12. Radioactives PART.II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. 1. 2. 3. 4. 5. 6. 7. YES D D D D Dn D Project Completion Date:Expected Date of Occupancy:. NO (for new construction or remodeling projects) ] Is your business listed on the reverse side of this form? (check all that apply). ] Will your business dispose of Hazardous Substances or Medical Waste in any amount? 3 Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? ] Will your business use an existing or install an underground storage tank? U Will your business store or handle Regulated Substances (CalARP)? ] Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 3 Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act). D CalARP Exempt Date Initials D CalARP Required Date Initials D CalARP Complete Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition .orrenovation of residential structures of four units or less. Contact the APCD for more information. 1. YES D 2. D 3. 4. 5. D D D NOm [][]5 Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facts/Dermits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Search the California School Directory at http://www.cde.ca.gov/re/sd/ for public and private schools or contact the appropriate school district). Has a survey been performed to determine the presence of Asbestos Containing Materials? Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities:Briefly describe proposed project: hat to/the best of my knowledge and balief the r ses madt hereiji are tiue and corn f <£- / II Name of Ovtyger or Authorized Agent SignatureVQf Owner or Authorized Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: FOR OFFICIAL USE ONLY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD*APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMD APCD RELEASED FOR OCCUPANCY COUNTY-HMD APCD *A stamp in this box only exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (02/11) County of San Diego -DEH- Hazardous Materials Division BUILDING ENERGY ANALYSIS REPORT PROJECT: Nicole Miller T.I. 1923 Calle Barcelona, Bldg 3, #141 Carlsbad, CA 92009 Project Designer: Architectural Concepts 1711 28th St. San Diego, CA92102 (619)2068328 Report Prepared by: David Sosna SOSNA ENERGY CONSULTING 5390 Reservoir Drive San Diego, CA 92115 (619)698-0566 *\: Job Number: 11008T Date: 6/24/2011 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC - www.energysoft.com. EnergyPro 5.1 by EnergySoft User Number 3102 RunCode: 2011-06-24T09:20:09 10:110087 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form LTG-1-C Certificate of Compliance 3 Form LTG-2-C Lighting Controls Credit Worksheet 7 Form LTG-3-C Indoor Lighting Power Allowance 8 Form LTG-4-C Tailored Method Worksheet 9 Form LTG-MM Lighting Mandatory Measures 13 EnergyPro 5.1 by EnergySoft Job Number: ID: 11 POST User Number: 3102 Project Name Nicole Miller T.I. Project Address 1923 Calle Barcelona, Bldg 3, #141 Cartsbac Climate Zone 7 Total Cond. Floor Area 1,340 Date 6/24/2011 Unconditioned Floor Area 0 CERTIFICATE OF COMPLIANCE (Parti of4)LTG-1C GENERAL INFORMATION Building Type:0 Nonresidential O High-Rise Residential D Hotel/Motel Guest Room D School D Relocatable Public School 0 Conditioned Spaces D Unconditioned Spaces Phase of Construction: D New Construction D Addition O Alteration Method of Compliance: HI Complete Building D Area Category 13 Tailored Documentation Author's Declaration Statement I certify that this Certificate of Compliance documentation is accurate and complete. Name David Sosna Company SOSMA ENERGY CONSULTING Address 5390 Rese/vo/r Drive City/State/Zip San Diego, CA 92115 Signature Ss jf ^<*/st? Date 6/24/2011 CEA# CEPE# Phone (619) 698-0566 The Principal Lighting Designer's Declaration Statement • I am eligible under Division 3 of the California Business and Professional Code to accept responsibility for the lighting design. • This Certificate of Compliance identifies the lighting features and performance specifications required for compliance with Title 24, Pages 1 and 6 of the California Code of Regulations. • The design features represented on this Certificate of Compliance are consistent with the information provided to document this design on the other applicable compliance forms, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Name MargitWhiUock Company Architectural Concepts Address City/State/Zip San Diego, CA 92102 Signature /I L-—-1 Phone (619) 206-8328 License # C> '2'\'~Lt:>O Date .u Lighting Mandatory Measures Indicate location on building plans of Mandatory Measures Note Block: _ LIGHTING COMPLIANCE FORMS & WORKSHEETS (check box if worksheets is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms; please refer to the Nonresidential Manual published by the California Energy Commission. ED LTG-1C Pages 1 through 4 Certificate of Compliance. All Pages required on plans for all submittals. 0 LTG-2C Lighting Controls Credit Worksheet LTG-3C Indoor Lighting Power Allowance 1 through 4 Tailored Method Worksheet LTG-5C Pages 1 and 2 Line Voltage Track Lighting Worksheet EnergyPro 5.1 by EnergySoft User Number. 3102 RunCode: 2011-06-24T09:20.-09 ID: 11008T Page 3 of 13 CERTIFICATE OF COMPLIANCE Project Name Nicole Miller T.I. (Part 2 of 4) LTG-1 C Date 6/24/2011 INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Installation Certificate, LTG-1- INST (Retain a copy and verify form is completed and signed.) Certificate of Acceptance, LTG-2A and LTG-3A (Retain a copy and verify form is completed and signed.) Field Inspector D Field Inspector D A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power listed on this Lighting Schedule is only for: 0 CONDITIONED SPACE P UNCONDITIONED SPACE ™ The actual indoor lighting power listed below includes all installed permanent and portable lighting systems in accordance with§146(a). Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be included in the 0 calculation of actual indoor lighting power density in accordance with the Exception to §1 46(a). All portable lighting in excess of 0.2 watts per square foot is totaled below. A None or Item Tag LT-1 LT-2 LT-3 LT-4 LT-5 LT-6 LT-8 LT-9 Luminaire (Type, Lamps, Ballasts) B Complete Luminaire Description1 (i.e, 3 lamp fluorescent traffer, F32T8, one dimmable electronic ballasts) 35wLow Voltage Halogen 1 Lamp 13w Compact Triple 4 Pin 50w Low Voltage Halogen Chandelier-18 lights LT-5 Chandelier-Slights 15w per ft Track Light (with Current Limiter) American Fluorescent L.E.D. wall sconce Chandelier-4 lights-CFL Exit lighting-2 watt LED Installed Watts C D Watts perLuminaire138.0 18.0 54.0 1,080.0 300.0 15.0 9.0 100.0 2.0 E How wattage Was determined CEC Default From NA80 m m n n m n n n n D n n n o n a a a n "a? o T3 O>^""C 0 1 "O <O>oo o<1- n o a m m a m m m n a a n a p a a a a n F Number ofLurninaires8 13 5 1 1 24 4 3 2 Installed Watts Page Total: Building total number of pages: Installed Watts Building Total (Sum of all pages) Enter into LTG-1 C Page 4 of 4 G GT X •ad® **-'— a)(8 £3 C §•— 2* 304 234 270 1,080 300 360 36 300 4 2,888 H Field Inspector2 1q- a a a a a a n a a ,a •D' O P D a d a a Po 1 a o a n a a D p D a a a p p p -ap p p p 2,888 1 . Wattage shall be determined according to Section 130 (d and e). Wattage shall be rating of light fixture, not rating of bulb. 2. If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. EnergyPro 5. 1 by EnergySoft User Number: 3102 RunCode: 2011-06-24709:20:09 ID: 11008T Page 4 of 13 CERTIFICATE OF COMPLIANCE (Part 3 of 4)LTG-1 C Project Name Nicole Miller T.I.&24/2011 INDOOR LIGHTING SCHEDULE and RELD INSPECTION ENERGY CHECKLIST Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit areas > 250 ft2, automatic daylighting controls for daylit areas > 2,500 fr, d) shut-off controls, e) display lighting controls, f) tailored lighting controls - general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic controls for retail stores > 50,000 fr, in accordance with Section 1 31 . MANDATORY LIGHTING CONTROLS - HELD INSPECTION ENERGY CHECKLIST FfeW Description Number of Unite Location in Building Special Features Pass Fan 1 a IT'S MA*luM T a a a o a !f 4 HAdUM,a a a a a IT- 6 MAfJuAl a a IT- 6 HA 4uAt OtMH^l- lUUML o a andaa a a a a a a a a a a a o a a a a a D o a a D a a o a o D a SPECIAL FEATURES INSPECTION CHECKLIST (See Page 2 of 4 of LTG-1C) The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Field Inspector's Notes or Discrepancies: EnergyPm 5.1 by EnergySoft User Number 31 02 RunCode: 20f f-06-24TO9.-20:09 ID.11008T Page 5 of 13 CERTIFICATE OF COMPLIANCE Project Name Nicole Miller T.I. (Part 4 of 4) LTG-1C Date 6/24/201 1 CONDITIONED AND UNCONDITIONED SPACE LIGHTING MUST NOT BE COMBINED FOR COMPLIANCE Indoor Lighting Power for Conditioned Spaces Installed Lighting (from Conditioned LTG-1C, Page 2) Lighting Control Credit Conditioned Spaces (from LTG-2C) Adjusted Installed Lighting Power Complies if Installed ^ Allowed Allowed Lighting Power Conditioned Spaces (from LTG-3C or PERF-1) Watts 2,888 235 2,653 I 2,682 Indoor Lighting Power for Unconditioned Spaces Watts Installed Lighting Q (from Unconditioned LTG-1C, Page 2) Lighting Control Credit . QUnconditioned Spaces (from LTG-2C) Adjusted Installed = 0 Lighting Power Complies if Installed ^ Allowed T Allowed Lighting Power Unconditioned Spaces (from LTG-3C) Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is ttie acceptance test for the Lighting system, LTG-2A and LTG-3A. The designer is required to check the acceptance tests and list all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires a test, list the different lighting and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Forms can be grouped by type of Luminaire controlled. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controls is installed in the building or space shall be certified as meeting the Acceptance Requirements. The LTG-2A and LTG-3A forms are not considered complete forms and are not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §10-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the LTG-2A and LTG-3A for each different lighting luminaire control(s) must be provided to the owner of the building for their records. Luminaires Controlled Equipment Requiring Testing Dimming - Manual Dimming - Manual Dimming - Manual Dimming - Manual Dimming - Manual Dimming - Manual Description 35w Low Voltage Halogen 15w per ft Track Light (with Current Lit American Fluorescent L.E.D wall scon Chandelier-18 lights 50w Low Voltage Halogen LT-5 Chandelier-3 lights Number of Luminaires controlled 8 24 4 1 5 1 Location Retell Retail Retail Retail Retail Retail LTG-2A and LTG-3A Controls and Sensors and Automatic Daylighting Controls Acceptance El El El El El 0 O D D D D D d D D O EnergyPro 5.1 by EnergySofi User Number: 31 02 RunCode: 2011-06-24T09:20:09 ID:11008T Page 6 of 13 LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG-2C Project Name Date Nicole Miller T. 1. 6/24/201 1 POWER ADJUSTMENT FACTORS (PAF) FOR NON-DAYLIGHT CONTROLS A Separate PAF Worksheet Must Be Filled Out for Conditioned and Unconditioned Spaces. Control Credits listed on this schedule are only for: 0 CONDITIONED SPACES O UNCONDITIONED SPACES A Room # Zone ID Areas Retail Retail Retail Retail Retail Retail B Lighting Control Description1 Dimming - Manual Dimming - Manual Dimming - Manual Dimming - Manual Dimming - Manual Dimming - Manual C Plan Reference LT-1 LT-6 LT-8 LT-4 LT-3 tT-5 D Room Area (ft2) 1,340 1,340 1,340 1,340 1,340 1,340 E Watts of Control Lighting 304 360 36 f,080 270 300 F Power Adjustments Factor2 O.fO 0.10 0.10 0.10 0.10 0.10 PAGE TOTAL Note: Conditioned and Unconditioned Space shall be separately totaled Building total of non-daylight control credit watts for all pages of LTG-2C Page 1 of 2 Enter building total of all daylight controls credit watts from LTG-2C Page 2 of 2 BUILDING TOTAL OF ALL CONTROL CREDIT WATTS (FOR BOTH NON-DAYLIGHT AND DAYLIGHT CONTROL CREDITS) Enter in LTG-1C; Page 4: Lighting Control Credit as appropriate for CONDITIONED or UNCONDITIONED Spaces G Control Credit Watts (ExF) 30 36 4 108 27 30 235 0 235 1 . Description shall be consistent with Type of Control defined in Table 146-C 2. Power Adjustment Factor taken from Table 146-C EnergyPro 5.1 by EnergySoft User Number: 3102 RunCode: 2011-06-24T09:20:09 ID: 11008T Page 7 of 13 INDOOR LIGHTING POWER ALLOWANCE LTG-3C Project Name Nicole Miller T.I. Date 6/24/2011 ALLOWED LIGHTING POWER (Chose One Method) A Separate LTG-3C must be filled out for Conditioned and Unconditioned Spaces. Indoor Lighting Power Allowances listed on this page are only for: 0 CONDITIONED SPACES D UNCONDITIONED SPACES COMPLETE BUILDING METHOD BUILDING CATEGORY (From §146 Table 146-E) WATTS PER (ft2) TOTALS X COMPLETE BLDG. AREA AREA ALLOWED WATTS WATTS AREA CATEGORY METHOD BUILDING CATEGORY (From §146 Table 146-F) WATTS PER (ft2) TOTALS X Area ft2 0 AREA ALLOWED WATTS 0 WATTS TAILORED METHOD Total Allowed Watts using the Tailored Method taken from LTG-4C (Page 1 of 4) Row 3 2,682 The indoor lighting power allowance using the Tailored Method of compliance shall be determined using the LTG-4C set of forms. A separate set of LTG- 4C forms shall be filled out for CONDITIONED and UNCONDITIONED spaces EnergyPro 5.1 by EnergySoft User Number 31 02 RunCode: 2011-06-24709:20:09 ID:11008T Page 8 of 13 TAILORED METHOD WORKSHEET (Part 1 of 4) LTG-4-C Project Name Date Nicole Miller T.I. 6/24/201 1 TAILORED METHOD SUMMARY - Separate Tailored Method Worksheets shall be filled out for Conditioned and Unconditioned Spaces: m CONDITIONED SPACES O UNCONDITIONED SPACES 1 . Allowed Watts for Illuminance Categories (Building Total from Column G from Tailored General Ligf Power Table below) iting I 1,608 Watts 2. Watts for Display Lighting 136\ [ OJ | 938J | OJ [ 1,074 Wall Display from Floor Display Ornamental/Special Very Valuable LTG-4C + From LTG-4C + Effects Display from + Merchandise = Total Watts Page 2 of 4 Page 2 of 4 LTG-4C Page 3 of 4 LTG-4C Page 3 of 4 3. Total Allowed Watts (add lines 1 and 2)| 2,682 Watts TAILORED ALLOWED GENERAL LIGHTING POWER A Room Number B Primary Function Type1 Retail Sales, Wholesale C Illuminance Category2 D D Room Cavity Ratio5 6.40 RCR from LTG-4C Page 4 of 4? Y N 0 O D a D a a a a n a a a a o a a n a a o n a a D n a n a a a a a a p n o a a a n n PAGE TOTAL BUILDING TOAL E Floor Area for Primary Function4 1,340 ft2 1,340 1,340 F Allowed LPD5 1.20 G Allowed Watts (EXF) 1,608 Watts 7,608 7,608 1 . From Table 1 46-G, Column 1 2. From Table 1 46-G, Column 2 or IESNA Handbook 3. If Column D checked 'N1 then enter <3.5 in this column 4. Floor area must be for Primary Function type listed in Table 146-G Column 1 . Floor area using the Area Category Method shall not be included 5. In accordance with Table 146-1 EnemvPro 5. 1 bv EneravSof, User Number: 3102 RunCode: 2011-06-24709:20:09 ID: 11008T Paoe 9 of 13 TAILORED METHOD WORKSHEET (Part 2 of 4) LTG-4C Project Name Nicole Miller T.I. Date 6/24/2011 m CONDITIONED SPACES D UNCONDITIONED SPACES DISPLAY LIGHTING; WALLS El Qualifying wall display systems shall be mounted within 10 ft to a wall, See §146(c) A Luminaire Description Retail B Mounting Height 8.0 C Mount Height Factor1 1.00 Total Length of Display Walls D E F ALLOTTED WATTS Wall Display Length in Linear Feet 8 8 Wall Display2 Power in (Watts /foot) 17.00 Linear feet Allowed Watts (CXDXE) 136 3B G H | 1 J DESIGN WATTS Lumin Code LT-3 Lumin QTY 5 WATTS/ LUMIN 54.0 Design Watts (HXI) 270 TOTAL WATTS Enter Line 2, Page 1 of LTG-4C K Allowed Watts (min F or J) 136 136 1. From Table 146-H 2. From Table 1 46-G Column 3 DISPLAY LIGHTING; FLOORS / 0 Qualifying floor display lighting systems shall be mounted no closer than 2 ft to a wall, See §146(c)3B A Lighting Description B Mounting Height C Mount Height Factor3 Total Area Floor Displays D E F ALLOTTED WATTS Floor Area4 (ft2) 7,340 Floor Display5 Power in W/ft2 Alloted Watts (CXDXE) G | H 1 J DESIGN WATTS Lumin Code Lumin QTY WATTS/ LUMIN Design Watts (HXI) TOTAL WATTS ft2 Enter on Line 2, Page 1 of LTG-4C K Allowed Watts (min F or J) 0 3. From Table 146-H as appropriate 4. This shall be the floor area of the primary function in accordance with §1 46(c)3B(ii) and Table 1 46-G Column 1 5. From Table 146-G Column 4 EnergyPro 5.1 by EnergySo User Number 3102 RunCode: 2011-06-24T09:20:09 ID:11008T Pape10of13 o CO 03 Q_ Ul LUX oco Q O | TAILORED W1 1Q Project NameNicole Miller T.I.COUly ex. COa Ul O az 2 D Ul a. COa I 13 CONDITIONE{2o111u.LU Ul_l 0UlQ. S Ul DC O 0 I DISPLAY L1GHTIN- X 0 u. Ul O 0 m SJJLVM MEiOa LOTTED WATTS^AllowedWattsmum of D or H) |_c o>i§o "5 cox c'p Watts/Lu11 LuminaireCode'S |2 oS*s i£Ornamental/Special Effects LigW/ff*~ca £ 1% u. c01 O S I13 i 1T-T O O § T* S i s o o 1 8. 1 Sen oc>ot— m 2 i g ci o 35 1 8 1 o§ CO T- tr> CO o> o o o ". 1 C? COCOO) si _i 5 CD O of Enter on L— o S CO£ o Total Floc 1 i H vith 146(c)3B(iii) aCD in accordancjO 3 1 "S.)or area of theColumn 51 . This shall be the fit2. See Table 146-GCLE DISPLA03 > DCUl Ul DC O Ul f\1NVHOH3If£ Ul CD =} DCUl (3 | DISPLAY LIGHTIN- , - X (9 Ul a o m - 1 55ua fTED WATTS9 Allowed Watts(Minimum ofD, GorK).1^ &Z c1 1 Si LuminaireCodeCD CO . — . O c8 g U- Q fscjJo!e im = coSO « £^X 5S^ Jll^ Ifc LLuminaire Nameor Location0 si !£O)| — a. c\fm_c co Si5 t o m slay Case AreCO Q H C O 1 Total Floor Aream I IT- ' CD C.o E 1!li li -2-? 15 5T "~ 52. CO 5f l~£ 1 « !l0) O.CO CO jr g g *1 S1! t <B ° CD 11 S CO g -ccr CD 3. This allowances is4. This shall be the fl(5. See§146(c)3B(iv)6. This shall be the aPage 11 of 13 |K T- y 1 1 s i ' U Q> 3 1 I EnergyPro 5. 1 by Enen TAILORED METHOD WORKSHEET Project Name /V/co/eM///erT./. 0 (Part 4 of 4) CONDITIONED SPACES UNCONDITIONED SPACES" JJG-4C Date 6/24/2011 ROOM CAVITY RATIO (RCR) WORKSHEET __ _____ _ RCR<3.5 s assumed instead of using one of the calculation methods listed below. Note- Table 146-1 provides__ _ the lowest liahtma Dower densitv values fnr nrRc »*,-,^ „„ , ____ u— „ r- e *° ' Proviaesvalues for RCRs which are less than 3.5RECTANGULAR SPACES NON-RECTANGULAR SPACES A D oom (W) (ft) "• 1 ...1— 1 Room Height • ._ RCR 5XHX(L+W)/ (LXW) | EnemvPro5.1bvEneravSt User Number. 3102 RmCode: 2011 -06.24ro9.-20.-09 Use calculation from Column F of this RCR Worksheet to enter into Column C of LTG-4C, Page 1 of 4 ID:11Q08T Page 12 of 13 LINE VOLTAGE TRACK LIGHTING WORKSHEET (Page 1 of 2) LTG-5C Project Name:Date: *T3 METHOD 1 - VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT(S) O This is the onfy option available for determining -wattage of line-voltage busway and track rated for more titan 20 amperes O One of four options available for determining wattage ofline-voilage busway and track rated for 20 amperes or less ^"X^ A ^X BRANCH CIRCUIT NAME OR ID S*Nx *\V \ 7 N 'tI K/ / i \ V """""-x^ "^^^_ "^x^ TOTAL: Enter total on the bottom of LTG-5C Page 2 of 2 B VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT "-"^x \ S D METHOD 2 - USE THE HIGHER OF: 45 WATTS / LINEAR FOOT OF TRACK - OR TOTAL RATED WATTAGE OF ALL LUMINAIRES D One of four options available for determining wattage of line-voltage busway and tract rated for 20 amperes or Jess A TRACK # OR NAME *X"~*XN~ ^"^S^ \ B LINEAR FEET OF TRACK % 1*1 4JM A \ c (W/LF) 45 45 45 45 45 45 x. 45 "*"'•*=^*-^ 45 45 45 45 45 45 45 45 45 D BxC (W) ''».»"•«,„...'^ £ TOTAL RATED WATTAGE OF ALL LUMINAIRES "^ "\. "\ TOTAL Enter total on the bottom of LTG-5C Page 2 of 2 F LARGER OF (Dor E) 2008 Nonresidential Compliance Form August 2009 ftoject Name:Date: LINE VOLTAGE TRACK LIGHTING WORKSHEET (Page 2 of 2) LTG-5C S D METHOD 3 - USE THE HIGHER OF: 12,5 WATTS / LINEAR FOOT OF TRACK - OR VA RATING OF INTEGRAL CURRENT LIMITER D One of four options available for determining wattage ofline-voltage busway and tract rated for 20 amperes or less. D Only integral current limiters -which are certified to the Energy Commission use this method. A Track or Name # t^cK ft | TRAdV* * 1 B Linear Feet of Track It 11 C (W/LF) 12.5 12.5 12.5 12.5 12.5 12.5 D BxC (W) 150 JS0 E VA Rating of Integral Current Limiter ' 90 W4H3 \9>0 UAiiS TOTAL; Enter total on the bottom of this page F Larger of (Dor E)100\%o 360 D METHOD 4 - DEDICATED TRACK LIGHTING OVERCURRENT PROTECTION PANEL Q One of four options available for determining wattage ofline-voltage busway and track rated for 20 amperes or less D Overcurrent protection panel is listed as defined in §101 in accordance with §130(d)3B(iv)a. D Overcurrent protection panel is used onfy with track lighting in accordance with §130(d)3B(iv)b. Cl Overcurrent protection panel is permanently installed in an electrical equipment room or permanently installed adjacent to the lighting panel board providing supplementary Overcurrent protection for the track lighting circuits served by the supplementary overcwrent protection panel in accordance witit §l30(d)3B(iv)c. O Overcurrent protection panel is prominently labeled in accordance with §130(d)3B(iv)d. OVERCURRENT PROTECTION PANEL "~™A~^~-^^_^•"•i NAME OR ID B ^\ Voltage of the Branch Circuit C "*" /A comP!ete ifet of j^aqterage Ratingjor Each Device Installed in the^Paael '~H^^^_ D Sum of the Ampere Rating of all Devices '^-x^^ """^^x^ TOTAL: Enter total on the bottom of this page E Sum of die Ampere Ratings of all of the Devices Times The Branch Circuit Voltage (BxD) \ ENTER TOTAL FROM METHOD 1 ENTER TOTAL FROM METHOD 2 ENTER TOTAL FROM METHOD 3 ENTER TOTAL FROM METHOD 4 TOTAL TRACK / BUSWAY WATTAGE: 2008 Nonresidential Compliance Form August 2009 Project Name Nicole Miller T.I. Date 6/24/2011 LIGHTING MANDATORY MEASURES: NONRESIDENTIAL LTG-MM Indoor Lighting Measures: §131 (d): Shut-off Controls For every floor, aft interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. 1. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 2.Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. §119(h):Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. §111:Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. §131 (a): individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor-to-ceiling walls. Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts §131 (b): per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(o): Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area conttolled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131 (c): Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less.6. Outdoor Lighting Measures: §130(c)1: Mandatory lighting power determination for medium base sockets without permanently installed ballasts §132(a):All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumens per Watt or are controlled by a motion sensor. §132(b):All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements. §132(c)1: All permanently installed outdoor lighting meets the control requirements listed. §132(c):Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi-Level Lighting Requirements listed. EnergyPro 5.1 by EnergySoft User Number: 3102 RunCode: 2011-06-24T09:20:09 ID: 11008T Page 13 of 13 •^ 00 oenVI w Ul g 8 1 I ft D I CFD:LandYe:* D 5 *«**•*lft«isiii