Loading...
HomeMy WebLinkAbout1925 CALLE BARCELONA; 164; CB032070; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 09-30-2003 Commercial/lndustriaI Permit Permit No: CB032070 Job Address: Permit Type: TI Sub Type: COMM Parcel No: Lot #: 0 Valuation: $180,000.00 Construction Type: NEW Occupancy Group: Reference #: Project Title: COLDWATER CREEK 6000 SF TI SHELL TO RETAIL 1925 CALLE BARCELONA CBAD St: 164 Status: ISSUED Applied: 07/28/2003 Plan Approved: 09/30/2003 Issued: 09/30/2003 Entered By: SB Inspect Area: Plan Check#: Applicant: JOYCE SEHl Owner: P.O. BOX 2653 92628 949-305-2889 5298 W/3W03 01 (13 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee $792.96 $0.00 $515.42 $0.00 $0.00 $37.80 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Red. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES CGP 4352 0 76 $0.00 $0.00 $0.00 $0.00 $3,276.00 $0.00 $0.00 $0.00 $0.00 $0.00 $90.00 $1 10.00 $46.00 $0.00 $0.00 $0.00 $0.00 $4,868.18 Total Fees: $4,868.1 8 Total Payments To Date: $51 5.42 Balance Due: $4,352.76 Clearance: NOTICE: Please take t approval of your project includes the" position" f fees, dedications, reservations, or other exactions hereafter collectively have 90 days from the date this perm was iss d to protest imposition of these feeslexactions. If you protest them, you must 'p follow the protest procedures set forth in Government Code Section 66020(a), and de the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified feeslexactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any ch vou have Drev iouslv been aiven a NOTICE s imilar to this. or as to wh ich the statute o f limitations has ~reviouslv otherw ise mired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NoCF~~ I EST. VAL. f 8 , 0 - Plan Ck. Deposit Legal Description Lot No. Subdivision NameINumber Unit Vo. Phase No. - Total # of units Assessor's Parcel # Existing Use ProDosed Use 42 Name Address city Statelzip Telephone # Fax # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exemDt therefrom, and the basis for the alleaed State License # License Class Designer Name Address City StatelZip Telephone State License # 0 of the work for which this permit is issued. 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit IS Insurance Company (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS t$lOOI OR LESS) 0 to become subject to the Workers' Compensation Laws of California. CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as s up to one hundred attorney's fees. lawful, and shall subject an employ damages as provided for in Section I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 1. 2. 3. I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): Business and Professions Code for this reason: 4. number I contractors license number): 5. of work): PROPERTY OWNER SIGNATURE DATE I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type Is the applicant or future building occupant required to submit a business plan, acutely hazardous ma program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE YES 0 NO 0 YES 0 NO FFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. DING AGEN I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work at any time after the wo APPLICANT'S SIGNATU DATE authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work 6.4.4 Uniform Building Code). WHITE: File YELLOW: Applicant PINK: Finance Clty of Carlsbad Final Building Inspection Dept: Building Engineering Planning Plan Check #: Permit #: CB032070 Project Name: COLDWATER CREEK 6000 SF TI SHELL TO RETAIL Address: 1925 CALLE BARCELONA #164 CMWD St Lite yI Date: Permit Type: Sub Type: Lot: 0 1111 912003 TI COMM Contact Person: GARY Phone: 7606340366 Sewer Dist: Water Dist: w inspected By: Inspected: Approved: Disapproved: Date U Inspected By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Comments: ...,,...,,,... 11....11...1.............1,.,,,,...,,.~..,,.......,.....~....,.~,.,.,...~~.......,..........,~*,,,,,,,,....,...,....*..,,...,,,,,,,,,,,,,~.., Inspection List Permit#: CB032070 Type: TI Date Inspection Item 11/25/2003 89 Final Combo 1 1 /25/2003 89 Final Combo 11/24/2003 89 Final Combo 11/24/2003 89 Final Combo 1 1/19/2003 89 Final Combo 11/19/2003 89 Final Combo 1 111 412003 18 Exterior Lath/Drywall 11/14/2003 18 Exterior Lath/Drywall 11/14/2003 29 Final Plumbing 11/14/2003 29 Final Plumbing 11/14/2003 39 Final Electrical 11/14/2003 39 Final Electrical 11/14/2003 49 Final Mechanical 11/14/2003 49 Final Mechanical 1111 012003 14 Frame/SteeVBolting/Weldin 10/27/2003 17 Interior Lath/Drywall 10/22/2003 24 Roughflopout 10/22/2003 34 Rough Electric 10/17/2003 14 FramelSteeUBoltingANeldin 1011 7/2003 34 Rough Electric 1011 7/2003 44 Rough/Ducts/Dampers 10/15/2003 21 Underground/Under Floor 10/15/2003 23 Gasflest/Repairs 10/15/2003 24 Roughflopout 10/08/2003 17 Interior Lath/Drywall 10/07/2003 17 Interior Lath/Drywall 10/07/2003 44 Rough/Ducts/Dampers COMM Inspector Act PS AP PS co RI RI RI PS co PS AP PS wc PS wc PS wc TP AP TP AP PS AP PS AP PK AP PK AP PK AP TP AP TP wc TP NR PS AP PS PA PS co RI RI RI RI COLDWATER CREEK 6000 SF TI SHELL TO RETAIL Comments EMR POST ADDED Q ENTRY HDR REST RMS REST RMS PARTY WALL COMPLETE 2 PARTY WALL TO 16FT - OOlN Wednesday, November 26,2003 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 1 1/25/2003 Permit# CB032070 Inspector Assignment: PS Title: COLDWATER CREEK 6000 SF TI Description: SHELL TO RETAIL Type: TI Sub Type: COMM Job Address: 1925 CALLE BARCELONA Suite: 164 Lot 0 Location: APPLICANT JOYCE SEHl Owner: Remarks: Phone: 9093239651 Inspector?> Total Time: Requested By: NA CD Description Comment Entered By: CHRISTINE 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical ---+- Associated PCRs/CVs InsDection History Date Description Act lnsp Comments 1111 9/2003 89 Final Combo CO PS EMR 11/14/2003 18 Exterior Lath/Drywall AP PS 11/14/2003 29 Final Plumbing wc PS 11/14/2003 39 Final Electrical wc PS 1 1/14/2003 49 Final Mechanical wc PS 11/10/2003 14 Frame/Steel/Bolting/Welding AP TP POST ADDED @ ENTRY HDR 10/27/2003 17 Interior Lath/Drywall AP TP 10/22/2003 24 Rough/Topout AP PS RESTRMS . 10/22/2003 34 Rough Electric AP PS 10/17/2003 14 Frame/Steel/Bolting/Welding AP PK 10/17/2003 34 Rough Electric AP PK 10/17/2003 44 RougidDuctdDampers AP PK 10/15/2003 21 UndergroundlUnder Floor AP TP 10/15/2003 23 GasTTest/Repairs WC TP 10/15/2003 24 Rough/Topout NR TP 10/08/2003 17 Interior LaWDrywall AP PS PARTY WALL COMPLETE PCR03235 ISSUED COLD WATER CREEK-STRUCT REVISI; TO STORE FRONT City of Carlsbad Bldg Inspection Request For: 1 1/19/2003 Permit# CB032070 Title: COLDWATER CREEK 6000 SF TI Description: SHELL TO RETAIL Type: TI Sub Type: COMM Job Address: 1925 CALLE BARCELONA Suite: 164 Lot 0 Location: APPLICANT JOYCE SEHl Owner: Remarks: Total Time: CD Description 19 Final Structural Inspector Assignment: PS Phone: 7606340366 Inspector: -5 I Requested By: GARY Entered By: KAREN Act Comment 29 Final Plumbing 39 Final Electrical 49 Final Mechanical I- Associated PCRsKVs Inspection History Date Description Act lnsp Comments PCR03235 ISSUED COLD WATER CREEK-STRUCT REVISI; TO STORE FRONT 11114/2003 1 111 412003 1 1 I1 412003 1 1 I1 412003 1 1 I1 012003 1012712003 10122/2003 10122/2003 1011 712003 1011 712003 1011 712003 1011 512003 1011 512003 1011 512003 10108/2003 1010712003 18 Exterior LatNDrywall 29 Final Plumbing 39 Final Electrical 49 Final Mechanical 14 FramelSteeUBoltingiWelding 17 Interior LathIDtywall 24 RoughiTopout 34 Rough Electric 14 FramelSteellBoltingiWelding 34 Rough Electric 44 RoughIDuctslDampers 21 UndergroundIUnder Floor 23 GaflestlRepairs 24 RougivTopout 17 Interior LatNDrywall 17 Interior LatNDtywall AP PS wc PS wc PS wc PS AP TP POST ADDED @ ENTRY HDR AP TP AP PS RESTRMS AP PS AP PK AP PK AP PK AP TP WC TP NR TP AP PS PARTY WALL COMPLETE PA PS 2 PARTY WALL TO 16FT - OOlN City of Carlsbad Bldg Inspection Request For: 10/07/2003 Permit# CB032070 Inspector Assignment: Title: COLDWATER CREEK 6000 SF TI Description: SHELL TO RETAIL Type: TI Sub Type: COMM Job Address: 1925 CALLE BARCELONA Suite: 164 Lot 0 Location: APPLICANT JOYCE SEHl Owner: Remarks: Total Time: Phone: 9093239651 Inspector: '<!, Requested By: GARY Entered By: CHRISTINE 6'- 00'' CD Description 44 Roug h/Ducts/Dampers a Associated PCRs/CVs Inspection History Date Description Act lnsp Comments CITY OF CARLSBAD NOTICE (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE TIME FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? YES PHONE @ CODE ENFORCEMENT OFFICER EsGil Cornoration In Partnership with S;overnment for Quiliiing Safety DATE: 9/26/03 JURISDICTION: City of Carlsbad 0 FILE PLAN CHECK NO.: 03-2070 SET: I11 PROJECT ADDRESS: 1925 Calle Barcelona Suite 154 PROJECT NAME: Coldwater Creek - TI o w 0 0 0 I7 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did dse the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephop Fax In Person t/ REMARKS: Applicant to slip sheet the signed ENV-1 and LTG-1 sheets and add notes in red on sheets Ppnd E;Of W By: Doug Moody Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ [7 PC 9/19/03 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 (858) 560-1468 + Fax (858) 560-1576 4 __ EsGil Corporation In Qartnership with Government for Building Safety -. DATE: 9/9/03 JURISDICTION: City of Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 03-2070 SET: I1 PROJECT ADDRESS: 1925 Calle Barcelona Suite 154 PROJECT NAME: Coldwater Creek - TI 0 The plans transmitted herewith have been corrected where necessary and substantially comply 0 The plans transmitted herewith will substantially comply with the jurisdiction’s building codes with the jurisdiction’s building codes. when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant‘s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Joyce Sehi P.O. Box 2653 ? , CA 92628 Esgii Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Joyce Sehi Date contacted: 9/ro(o?l (by: by) Telephone #: 949-305-2889 Fax #: 949-305-6684 Mail JTelephone Fax 1 In Person 0 REMARKS: By: Doug Moody Enclosures: Esgil Corporation 0 GA MB 0 EJ 0 PC 9/2/03 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + SanDiego, California 92123 4 (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 03-2070 9/9/03 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-2070 PROJECT ADDRESS: 1925 Calle Barcelona Suite 154 SET: I1 DATE PLAN RECEIVED BY ESGIL CORPORATION: 9/2/03 9/9/03 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): DATE RECHECK COMPLETED: This plan review is limited to the technical requirements contained in the Uniform-Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit three new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo --J City of Carlsbad 03-2070 9/9/03 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustria1 projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only willnot be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the u n res o I ve d is s u e. 2. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 Please clearly indicate the adjacent the new storefront doors to be safety glazing. a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 3. Please clarify the section view of all new interior partitions. Show: a) The gauge of the studs to be used was not indicated on the plans. Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". 4. Exits shall not pass through kitchens, store rooms, or spaces used for similar purposes. Section 1004.2.2. Please revise the plans to show the office not to exit through the stock room. 13. Plans shall indicate that drinking fountains comply with Section 11 17B.1 as either: a) b) The recessing of the drinking fountains has interfered with the required transfer space (minimum of 28") between the accessible water closet and the lavatory. Please revise the plans. Located completely in an alcove, 232" in width and 218" in depth. Positioned to not encroach into accessible pedestrian ways. - EsGil - Corporation In Partnership with Government for Building safety DATE: 8/8/03 JURISDICTION: City of Carlsbad 0 APPLICANT 0 PLAN REVIEWER aQiKE=> 0 FILE PLAN CHECK NO.: 03-2070 SET: I PROJECT ADDRESS: 1925 Calle Barcelona Suite 154 PROJECT NAME: Coldwater Creek - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and chected by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list The check list transmitted herewith is for your information. The plans are being held at Esgil and should be corrected and resubmitted for a complete recheck. Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. w The applicant's copy of the check list has been sent to: Joyce Sehi P.O. Box 2653 ? , CA 92628 0 Esgil Corporation staff did not advise the applicant that the plan check has been completed. w Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Joyce Sehi (VmM-) Date contacted: g-ll-03 (by: &- ) Telephone #: 949-305-2889 Fax #: Mail Telephone d Fax In Person 0 REMARKS: By: Doug Moody Enclosures: Esgil Corporation GA 0 MB 0 EJ 0 PC 7/29/03 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 03-2070 8/8/03 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 03-2070 OCCUPANCY: M USE: Retail TYPE OF CONSTRUCTION: VN ACTUAL AREA: 6000sf JURISDICTION: City of Carlsbad ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY J U RI SDI CTI ON: 7/28/03 STORIES: 1 HEIGHT: OCCUPANT LOAD: 150 DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/29/03 DATE INITIAL PLAN REVIEW COMPLETED: 8/8/03 FOREWORD (PLEASE READ): PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, Le., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 03-2070 8/8/03 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 2. Glazing in the following locations should be of safety glazing material in accordance with Section 2406.4 a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. 3. Please clarify the section view of all new interior partitions. Show: a) b) c) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate “to be ICBO approved”. Method of providing lateral bracing for the wall type P. Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 4. Exits shall not pass through kitchens, store rooms, or spaces used for similar purposes. Section 1004.2.2. 5. When more than one exit is required, the exit access shall be arranged such that there are no dead ends in hallways (to the fitting rooms) more than 20’ in length. Section 1004.2.6. 6. Please note on the plans “AC Cable is not allowed in A, B, E, HI and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits”. City of Carlsbad 03-2070 8/8/03 7. 8. 9. IO. 11. 12. 13. Please imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. Detail how floor drain trap seal is to be maintained. UPC Section 1007.0 (floor drain trap priming). Please revise the gas line plan to be consistent with the City of Carlsbad's roof mounted equipment policies. Note on the plans that new water closets and associated flushometer valves, if any, shall use no more than I .6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard AI 12.19.2. H & S Code, Section 17921.3(b). Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36" long and no more than 28" to 34" high. Section 1122B.4. Note on the plans that the drinking fountain(s) will comply with all applicable Title 24 provisions (bubbler height, etc.). Plans shall indicate that drinking fountains comply with Section 11 17B.1 as either: a) b) Located completely in an alcove, 232" in width and 118" in depth. Positioned to not encroach into accessible pedestrian ways. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 03-2070 8/8/03 VALUATION AND PLAN CHECK FEE Air Conditioning Fire Sprinklers TOTAL VALUE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-2070 180,000 PREPARED BY: Doug Moody DATE: 8/8/03 BUILDING ADDRESS: 1925 Calle Barcelona Suite 154 BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: VN Jurisdiction Code Icb IBy Ordinance 1994 UBC Buildina Permit Fee I v 1994 UBC Plan Check Fee w Type of Review: Complete Review 0 Structural Only U;rtitive F= Repeats 0 Other 0 Hourly n Hour* Esgil Plan Revlew Fee I $792.961 I $51 5.421 I $444.061 Comments: Sheet1 of 1 macvalue.doc PLAN N ING/ENG I N EE RI NG APPROVALS PERMIT NUMBER CB - z/020 DATE 7/38 /e ADDRESS #z(’ [~(AJ &d!b-~- RES I DENTIAL TENANT IMPROVEMEqlT) c -0 __.-.- ---- RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER 3 DATE PLANNER ENGINEER - DATE DocsIMisfoWlanning Engineering Approvals PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST do cl t do 0 Plan Check No. CB 04m(> Address IQS U 8arcefoq a Planner Chris Sexton Phone 1760) 602-4624 APN: - Net Project Density: DU/AC Zoning: Management Zone: 33 CFD (idout) #-Date of participathn: Remaining net dev acres: (For non-residential development: Type of land used created by this permit: 1 Circle One Leaend: Environmental Review Required: DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAURESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: a Item Complete Item Incomplete - Needs your action YES - NO r//TYPE YES - NO =TYPE - Coastal Zone AssessmentlCompliance Project site located in Coastal Zone? YESJ NO- YES- NO- If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 921084402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): If NO, complete Coastal Permit Determination Form now. ' Coastal Permit Determination Log #: CA Coastal Commission Authority? Coastal Permit Determination Form already completed? YES- NO- d. Foklow-Up Actions: -._ 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). - 2) Complete Coastal Permit Determination Log as needed. lnclusionary Housing Fee required: (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) YES - NO J' Data Entry Completed? YES - NO - Site Plan: 1. 2. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Guidelines 1. Applicability: YES NO 2. Project complies YES NO 1. 2. 3. 4. 5. Zoning: Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown Accessory structure setbacks: Required Front: Interior Side: Required Street Side: Required Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required 8-IL Shown - ~F :E* Height: Required e-k. Shown Parking: kk-- Shown Spaces Required (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown . Carlsbad Fire Department 032070 Fire Prevention 1635 Faraday Ave. ., Carlsbad, CA 92008 (760) 602-4660 Plan Review Requirements Category: Building Plan Date of Report: 09/04'2003 Reviewed by: Name: Joyce Sehi Plan Checker: Job Name: Job Address: Address: P.O. Box 2653 Citv, State: Costa Mesa CA 92628 a. Job#: 032070 Coldwater Creek Bldg #: CB032070 1925 Calle Barcelona Ste. or Bldg. No. 154 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. [7 Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 0 Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2nd 3rd Other Agency ID FD Job # KGW'o FD File # Carlsbad Fire Department 032070 . 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Date of Report: ~9/~4’2003 Reviewed by: Name: Joyce Sehi Plan Checker: Address: P.O. Box 2653 City, State: Costa Mesa CA 92628 Job Name: Coldwater Creek 032070 Job Address: 1925 Calle Barcelona Ste. or Bldg. No. 154 FIRE agrees to allow permiting of this project pending approval of the rackingkhelving plans. Installation or assembly of these fixtures prior to plan approval will result in revocation of building permit. Garlsbad Fire Department 032070 1635 Faraday Ave. “Carlsbad, CA 92008 Fire Prevention (760) 602-4660 B Plan Review Requirements Category: Building Plan Date of Report: 08/05/2003 Reviewed by: Plan Review Requirements Category: Building Plan Date of Report: 08/05/2003 Reviewed by: Name: Joyce Sehi Address: P.O. Box 2653 City, State: Costa Mesa CA 92628 Plan Checker: Job Name: Job Address: Job#: 032070 Coldwater Creek Bldg #: CB032070 1925 Calle Barcelona Ste. or Bldg. No. 154 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2nd 3 rd Other Agency ID FD Job # 032070 FD File # . Requirements Category: Building Plan 6' Requirement: Pending 05.16 A/S Design Sprinkler system design shall be in accordance with standards set forth by the National Fire Protection Association and UBC Standards 38-1 and 38-2. Permits are required prior to installation. I Requirement: Pending 05.29 High Piled Combustible Storage Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high piled stock piling is to be done, submit a complete storage plan and description of the commodoties to be stored. Show compliance with Article 81 of the Uniform Fire Code. Plans, specifications and calculations shall be certified by a licensed fire protection engineer or other person deemed competent by the Chief, and submitted in the name of a licensed sprinkler contractor. Warehouse buildings for which no specific use, occupant, product, activity or storage array has been identified, shall be protected by sprinkler system designed to deliver water at the rate of .45 gallons per square foot, throughout a 3000 square foot design area. THE ATTACHED FS-101 FIRE SPRINKLER PLAN IS DISAPPROVED. THERE IS NOT SUFFICIENT INFORMATION PROVIDED TO DETERMINE APPROPRIATENESS OF THE ATTACHED DESIGN. SECTION 15300 STATES THAT A LICENSED SPRINKLER CONTRACTOR SHALL SUBMIT PLANS FOR INSTALLATION OF SPRINKLERS WITHIN THIS PROJECT. I Requirement: Pending 05.18 Fire Extinguishers Required Provide one 2A1 OBC fire extinguisher for each 6000 square feet or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. Provide notes on the plans that the extinguisher will be provided. CORRECTION: LOCATE TOP OF HANDLE OF FIRE EXTINGUISHERS AT 44 INCHES AFF MAX. I Requirement: Pending 05.22 Exit Door Hardware Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exception: In group B occupancies, key locking hardware may be used on the Main Exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or adjacent to the door stating, "This door to remain unlocked during business hours." For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is occupied." See item 32 for additional exit door hardware requirements. DOOR 103 (MERCH. HALLWAY) SHALL BE REQUIRED TO HAVE SINGLE ACTION HARDWARE. LOCKSET ON EXIT DOOR DISAPPROVED FIRE SHALL REQUIRE ADDITIONAL INFORMATION OF THE PROPOSED INSTALLATION/USE OF 'MOBILE MERCHANDISING UNITS'. FIRE SHALL REQUIRE A SCHEMATIC OF UNITS INCLUDING MATERIALS TO BE USED (NO SOLID SHELVING PERMITTED), DIMENSIONS OF ASSEMBLED PRODUCT, AND PROPOSED METHOD OF MAINTAINING FLUE SPACE BETWEEN INDIVIDUAL UNITS. Page 1 oaio5io3 TITLE 24 REPORT Title 24 Report for: Coldwater Creek - The Forum at Carlsbad I935 TP Calle Barcelona Carlsbad, CA 92009 Project Designer: Callison Architecture, Inc. 1420 Fifth Avenue #2400 Seattle, WA 981 01 (206) 623-4646 Report Prepared By: Gregory Schnackel, P.E. Dale Schnackel Company 3035 South 72nd Street Omaha, NE 68124-3583 (402) 391 -7680 A Job Number: 0331 1 Date: 711 712003 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoR Job Number. 0331 1 User Number 4094 r! Y 0 U July 23,2003 c m COUGHLIN PORTERLUNDEEN e g h ‘yl M tu - U TI - e Y w M - Eric Lofgran Callison Architecture 1420 Fifth Avenue, Suite 2400 Seattle, WA 98101-2343 d RE: Coldwater Creek, The Forum at Carlsbad Structural Review Dear Eric: Per your request, we have reviewed the structural drawings to confirm that the existing structure is adequate to support the proposed mechanical units. There are three mechanical units and are located per the attached drawing. According to our analysis, the existing structure is adequate to support these mechanical units. Please call me if you have any questions, comments or if the above information is incorrect. Sincerely, COUGHLIN PORTER LUNDEEN, INC. 5- Eric A. Dam, P.E., S.E. Project Manager Attachment 217 PINE STREET . SUITE 300. .. .I .......... ____;___..A- 4 ,I - . >\ i :.; ......... ............... --- ...... ........... ____. _.__ ~ _._.. ............... I, 0 bj 1 h \