Loading...
HomeMy WebLinkAbout1925 CALLE BARCELONA; 169; CB162763; PermitCity of Carlsbad 09-20-2016 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB162763 Building Inspection Request Line (760) 602-2725 Job Address: 1925 CALLE BARCELONA CBADSt: 169 Permit Type: Tl Sub Type: COMM Status: ISSUED Applied: 07/18/2016 Entered By: SLE Parcel No: 2550120400 Lot#: 0 Valuation: $56,081.00 Construction Type: NEW Occupancy Group: Reference# Project Title: PRESSED JUICERY: 1,125 Tl Plan Approved: 09/20/2016 Issued: 09/20/2016 Inspect Area Plan Check #: ADD RESTROOM, SINKS AND SOFT SERVE MACHINES Applicant: ROBERT CICHOCKI 1550 17TH ST SANTA MONICA CA 90404 781-223-3526 Building Permit Add'l Building Permit Fee Plan Check Add'l Building Permit Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedidted Plan Review $436.57 $0.00 $305.60 $0.00 $0.00 $15.70 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3.00 $0.00 Total Fees: $1,087.49 Total Payments To Date: Inspector: Owner: T-C FORUM AT CARLSBAD L L C C/0 TIAA-CREF 4675 MACARTHUR CT #1100 NEWPORT BEACH CA 92660 Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee Green Bldg Standards Plan Chk TOTAL PERMIT FEES $1,087.49 Balance Due: Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $163.00 $89.00 $74.62 $0.00 $0.00 $0.00 $0.00 ?? ?? $1,087.49 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fe x i n f whi h r vi sl n iv n N Tl imil r hi r whi h f li i i r i I h i , THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0ENGINEERING 0BUILDING Ccicyof Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov Plan Ck. Deposit Date\- DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) } • I l...\ · ..(., f 1 "J_ '2... 5 +-t-'2..... t.q_."\o. o-l-: VV\ pf"O\Ie-'t"f)e. f)'-t'-::t:f\-{~r~C}(' r-e..-(")0-..JC>-l;.e.v") ....... -t.V\ coo • ,e:.Y"I 0 • r-e..;>-}'("0~11"'\.; <::.~ n~-:,1 s-<;)\+ Se.J'\Je.. Mo..e-.k\V\ ~-L :t ~s-{o..{~ J; f\e-w "Sto-!'e...-h-o;t 5t<:A~ \~I r\.Glf\-~dJr~l. FIREPLACE YESO AIR CO~IONING FIRE ~KLERS N~ YES .2SJNO D YES_KI NOD EXISTING USE \ GARAGE (SF) PATIOS (SF) r~~\ APPLICANT NAME• PROPERTY OWNER NAME ADDRESS ~4o\f CITY STATE ZIP PHONE FAX EMAIL ,CA)\t"'\ DESIGN PROFESSIONAL STATe A qoE\ott FAX EMAIL STATE LIC. # (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law !Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exem.[>t therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby afflnn under penaffy of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which lhis penni! is issued. ~e and will maintain worker o ensation, as required by ection 3700 of the Labor Code, for the perfonnance of the work f~ which~ penni! is issued. My workers' compensation ins ranee carrier and policy number are: Insurance Co. r\ 5 on Policy No. Cfo 7"-t.:? ~ .5 -2o I b Expiration Date't-J.:;¥JL.!,.L..."-'"q...~-- ~section need not be completelj if the permH is lor one hundred dollars ($100) or less. U Certificate of Exemption: I Certify that in the performance of the work for which this penni! is issued, I shall not employ any pe/son in any manner so as to become subject to the Workers' Compensation Laws of Cal~omia. WARNING: Failure to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, of the Labor code, interest and attorney's fees. Jl5 CONTRACTOR I hereby afflnn that I am exempt from Contractor's License Law for the following reason: D D D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered lor sale (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have tile burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes Do 2. I (have I have not) signed an application for a building pennH for the proposed work. 3. I have contracted with the following person (finn) to provide the proposed construction (include name address I phone I contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work Onclude name I address I phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): Jl5 PROPERTY OWNER SIGNATURE 0AGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Acr? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management districr? 0 Yes 0 No Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? 0 Yes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. Lender's Name I certify that I have read the application and state that the above lnfonmation is conectand that the Information on the plans is accura1e.l agree to complyi'Ath all City ordinances and Slate ICMS relating to building construction. I hereby authorize representative of the City of Carlsbad to enter UJXln the above mentioned property i:Jr inspection purJXJSElS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permtt is required for excavations over 5'0' deep and demoliOOn or construction of structures over 3 stories in height. EXPIRATION: Every permtt issued by the Building Offdal under the provisK>ns of this Code shall expire by lirnttation and become null and void if the building oroork authorized 180 days from the date of such permtt or if the building or oork authorized by such · is suspended or abandoned at any time after the oork is commenoed for a DATE permit is not commenoed within (Sectbn 106.4.4 Uniform Building Code). c • STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. DELIVERY OP110NS PICK UP: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On Pg. 1) MAIL TO: o CONTACT (Listed above) o OCCUPANT (Listed above) o CONTRACTOR (On pg. 1) MAIL/ FAX TO OTHER:---------------~- A$ APPLICANT'S SIGNATURE (Office Use Only) CA o ASSOCIATEDCB#------------ o NO CHANGE IN USE/ NO CONSTRUCTION o CHANGE OF USE/ NO CONSTRUCTION DATE Inspection List Permit#: CB162763 Type: Tl COMM PRESSED JUICERY: 1,125 Tl ADD RESTROOM, SINKS AND SOFT SER Date ~~~ Inspection Item Inspector Act Comments 10/18/2016 17 Interior Lath/Drywall py AP 10/18/2016 17 Interior Lath/Drywall PY PA 10/12/2016 84 Rough Combo MC AP 09/22/2016 21 Underground/Under Floor py AP 09/22/2016 24 Roughffopout py AP 09/22/2016 31 Underground/Conduit-Wirin py AP Thursday, December 15, 2016 Page 1 of 1 PERMIT INSPECTION HISTORY REPORT (CB162763) BLDG-Commercial 07/18/2016Application Date:Permit Type:Owner:T-C FORUM AT CARLSBAD LLC Subdivision:Tenant Improvement 09/20/2016Work Class:Issue Date: 1925 Calle Barcelona , 169 Carlsbad, CA Address:04/17/2017Expiration Date:Status: IVR Number: 715861 Closed - Finaled Scheduled Date Inspection Type Inspection No.Inspection Status Primary Inspector Reinspection CompleteActual Start Date 11/14/2016 11/14/2016 BLDG-44 Rough/Ducts/Dampe rs 000988-2016 Partial Pass Andy Krogh Reinspection Incomplete COMMENTS PassedChecklist Item BLDG-Building Deficiency Pending pcr for deletion of rear cooler and new t-grid and lights Yes BLDG-85 T-Bar, Ceiling Grids, Overhead 000989-2016 Partial Pass Andy Krogh Reinspection Incomplete COMMENTS PassedChecklist Item BLDG-Building Deficiency Pending pcr for deletion of rear cooler and new t-grid and lights in that area Yes 11/28/2016 11/28/2016 BLDG-33 Service Change/Upgrade 002933-2016 Passed Michael Collins Complete NOTES Created By TEXT Created Date Michael Collins EMR emailed to SDGE.11/28/2016 12/09/2016 12/09/2016 BLDG-Final Inspection 004892-2016 Failed Michael Collins Reinspection Complete COMMENTS PassedChecklist Item BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No NOTES Created By TEXT Created Date Michael Collins See card for corrections.12/09/2016 12/14/2016 12/14/2016 BLDG-Final Inspection 005463-2016 Passed Michael Collins Complete COMMENTS PassedChecklist Item BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes NOTES Created By TEXT Created Date Michael Collins See card for corrections.12/09/2016 December 14, 2016 Page 1 of 1 <<~) ~ CITY OF CARLSBAD Building Division INSPECTION RECORD: 0 INSPECTION RECORD CARD WITH APPROVED PLANS MUST BE KEPT ON THE JOB 0 CALL BEFORE 3:30pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Building AND CLICK ON "Re~st Inspection" DATE:'-1- Fire Prevention Type of Inspection CODE# BUILDING CODE# STORMWATER REV 10/2012 CB162763 169 1925 CALLE BARCELONA 5f.R '3:1- PRESSED JUICERY 1,125 Tl ADD RESTROOM, SINKS AND SOFT SERVE MACHINES Tl COMM Lot# ROBERT CICHOCKI RECORD COPY SEE BACK FOR SPECIAL NOTES EsGil Corporation In (!Jartnersliip witli government for (JJuiCtfino Safety DATE: 9/9/16 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 16-2763 SET: III PROJECT ADDRESS: 1923 Calle Barcelona Suite 169 PROJECT NAME: Pressed Juicery -TI ,0 A~LICANT b--JORIS. Q PLAN REVIEWER Q FILE I:8J The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [8J EsGil Corporation staff did not advise the applicant that the plan check has been completed. D EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contactect-----Telephone #: Date contacted: __..:>Q ~ Email: Mail Telephone Fax '(/n Person [8J REMARKS: The person responsible for the ENV documents shall sign all sheets. By: Doug Moody EsGil Corporation D GA D EJ D MB D PC Enclosures: 9/1/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In q?artnersliip witli government for (]Jui(aing Safety DATE: 8/18/16 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 16-2763 SET: II tttJ.5 PROJECT ADDRESS: 1921 Calle Barcelona Suite 169 PROJECT NAME: Pressed Juicery -TI 1:1 _pPLICANT ...,..e:r JURIS. 1:1 PLAN REVIEWER 1:1 FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. C8J The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil Corporation staff did not advise the applicant that the plan check has been completed. 1:8:1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Robert Cichocki Telephone#: 781-223-3626 Date co~acted:6 J \ 0 (by()U Email: rob.cichocki@pressedjuicery.com ~ail ~~on~ Fax In Person D REMAR~" By: Doug Moody EsGil Corporation D GA D EJ D MB D PC Enclosures: 8/11/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 16-2763 8/18/16 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring two corrected sets of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 2. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 580# rooftop air handler unit. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. I was unable to find the calculations to accompany the Structural plans? Please clarify the plans sheet 54.1 appears to show alterations to the building structure? Please provide a description of the scope and complete plans, details and calculations. 4. Provide a section view of all new interior partitions. Show: a) Method of attaching top plates to structure. (Indicate the size, type and number of connectors). No information provided in detail 01 on sheet A4.1 b) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. ). No information provided in detail 01 on sheetA4.1 5. Provide a section view of the new hard lid ceilings. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICC approved". The studs shown are over span and no connection is shown. Please complete the detail on sheet A4.3 b) Method of attaching top to the structure and lateral bracing. No information provided. c) Show height of the hard lid ceilings from floor, hard lid ceilings to roof framing or floor framing. City of Carlsbad 16-2763 8/18/16 8. Provide complete energy designs for the proposed changes in the envelope (store front glazing) systems. Provide the completed ENV-forms showing energy compliance. No information provided 9. The completed and signed ENV-1 forms must be imprinted on the plans. No information provided 11. Disaggregation of electrical circuits. Electrical power distribution systems shall be designed to permit the disaggregated measurement of electrical load energy uses downstream from the service meter according to Table 130.5-B. Additive and subtractive methods may be used to determine aggregate and disaggregated energy use. This may be accomplished by any of the following methods: Please imprint on the plans the manufacturer's name and model number of the split buss panel to be use to meet the requirement. 12. Multilevel lighting controls are required in areas exceeding 100 square feet in area and have a connected lighting load exceeding .5 watts per square foot (Classrooms are .7 watts). Review ES Table 130.1-A for design requirements. Include control placement and design on the floor plans. (AB switching no longer complies for most fixture types.) There is not a lighting control schedule so there is no way for me to determine if the controls are compliant. 18. Please correct the enlarged restroom plan to show the interior width to be 7'4" consistent with the floor plans (7'2" will not provide the required clearances). The plans still show the restroom to be 7'2" and not 7' 4" which is necessary. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In q?artnersliip witli <]overnment for c:Bui{aing Safety DATE: 7/27/16 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 16-2763 SET: I JttZS PROJECT ADDRESS: "1928 Calle Barcelona Suite 169 PROJECT NAME: Pressed Juicery -TI ~PLICANT ~ :_~RIS. 1:1 PLAN REVIEWER 1:1 FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. D The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [8J The check list transmitted herewith is for your information. The plans are being held at EsGil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D EsGil Corporation staff did not advise the applicant that the plan check has been completed. ~ EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Robert Cichocki Telephone#: 781-223-3626 ~Date C<yftacted:..:::J h=f--thy:Y't.J Email: rob.cichocki@pressedjuicery.com -=EMail~ (fe!e9.hon~ Fax In Person D REMAR~ ( {'f\_ By: Doug Moody EsGil Corporation 0 GA 0 EJ 0 MB 0 PC Enclosures: 7/19/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 16-2763 7/27/16 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 16-2763 OCCUPANCY: B TYPE OF CONSTRUCTION: VB ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 7/18/16 DATE INITIAL PLAN REVIEW COMPLETED: 7/27/16 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Restaurant ACTUAL AREA: 1225sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 16 DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/19/16 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 16-2763 7/27/16 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring two corrected sets of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide evidence of Health Department approval (for restaurants), where regulated by the local Health Department. 2. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 580# rooftop air handler unit. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. 3. Please complete the wall legend, indicate on the plans the wall types and reference the appropriate construction details. 4. Provide a section view of all new interior partitions. Show: a) Method of attaching top plates to structure. (Indicate the size, type and number of connectors). b) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 5. Provide a section view of the new hard lid ceilings. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICC approved". b) Method of attaching top to the structure and lateral bracing. c) Show height of the hard lid ceilings from floor, hard lid ceilings to roof framing or floor framing. 6. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as follows: a) All ceilings shall use a Heavy Duty T-bar grid system. -------------------------------------- . City of Carlsbad 16-2763 7/27/16 b) c) d) e) f) The width of the perimeter supporting closure angle shall be not less than 2 inches. In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle. The other end in each horizontal direction shall have a %" clearance from the wall and shall rest upon and be free to slide on a closure angle or a listed assembly. Ceiling areas over 1 ,000 ft-2 must have horizontal restraint wires (typically restraint would consist of four 12 gauge wires splayed goo to each other and sloped 45° to the horizontal, spaced 12" o.c.). Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. 7. Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 8. Provide complete energy designs for the proposed changes in the envelope (store front glazing) systems. Provide the completed ENV-forms showing energy compliance. 9. The completed and signed ENV-1 forms must be imprinted on the plans. 10. Please have the document author sign all of the required MCH forms. 11. Disaggregation of electrical circuits. Electrical power distribution systems shall be designed to permit the disaggregated measurement of electrical load energy uses downstream from the service meter according to Table 130.5-B. Additive and subtractive methods may be used to determine aggregate and disaggregated energy use. This may be accomplished by any of the following methods: 1. Separate switchboards, motor control centers or panelboards to which are connected only the required load or group of loads; or 2. Subpanels of the above to which are connected only the required load or group of loads and for which the subpanelload can be independently measured in aggregate; or 3. Branch circuits, taps or disconnects requiring overcurrent protection devices rated 60 amperes or greater. 12. Multilevel lighting controls are required in areas exceeding 100 square feet in area and have a connected lighting load exceeding .5 watts per square foot (Classrooms are .7 watts). Review ES Table 130.1-A for design requirements. Include control placement and design on the floor plans. (AB switching no longer complies for most fixture types.) . City of Carlsbad 16-2763 7/27/16 13. Shut-Off Controls: Each floor, each space (not exceeding 5,000 square feet), and each type (general, display, and ornamental) of lighting shall be individually capable of being automatically shut-off when the building is unoccupied. Include the control design. (A percentage of egress lighting is now included in the shut- off requirement). ES 130.1 (c) 14. Specify on the plans: Water conserving fixtures: New water closets shall use no more than 1.28 gallons of water per flush, lavatories and kitchen faucets may not exceed 2.2 GPM, and showers may not exceed 2.5 GPM of flow. CPC Section 402.0. 15. Please revise the plumbing plans to show the required clean-outs per section 707 and 719 of the UPC. 16. Detail how floor drain trap seal is to be maintained. UPC Section 1007.0 (floor drain trap priming). 17. Please correct the waste line to show the vent for the water closet to be a minimum of a 2". 18. Please correct the enlarged restroom plan to show the interior width to be 7'4" consistent with the floor plans (7'2" will not provide the required clearances). To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City or Carlsbad 16-2763 7/27/16 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City or Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: 16-2763 DATE: 7/27/16 BUILDING ADDRESS: 1923 Calle Barcelona Suite 169 BUILDING OCCUPANCY: B BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Tl 1225 45.78 Air Conditioning Fire Sprinklers TOTAL VALUE JurisdK:tion Code cb By Ordinance Bldg. Permt Fee by Ordnance ..... Plan Oleck Fee by Ordinance Type of Review: 0 Complete Review 0Repetitive Fee .,... Repeats Comments: D Other D Hourly EsGil Fee Reg. VALUE Mod. 0 Structural Only t------tl Hr. @ • ($) 56 081 56,081 $432.111 $280.871 $241.981 Sheet 1 of 1 macvalue.doc + -«~)> ~ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 07/28/2016 PROJECT NAME: PRESSED JUICERY Tl PROJECT ID:CB162763 PLAN CHECK NO: 1 SET#: 1 ADDRESS: -±m CALLE BARCELONA STE 169 APN: 2550120300 VALUATION: $56,081 11lS This plan check review is complete and has been APPROVED by: LAND DEVELOPMENT ENGINEERING DIVISION Final Inspection by the Construction Management Division is required Yes X No D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: ROB.CICHOCKI@PRESSEDJUICERY.COM Chris.Sexton@carlsbadca.gov Gina Ruiz 760-602-4()75 Gina.Ruiz@carlsbadca.gov Christopher.Giassen@carlsbadca.gov D Linda Ontiveros 760-602-2773 linda.Ontiveros@carlsbadca.gov VaiRay Nelson 760-602-27 41 VaiRay.Nelson@carlsbadca.gov Gregory .Ryan@carlsbadca.gov Cindy Wong 760-602-4662 Cynthia.Wong@carlsbadca.gov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov For questions or clarifications on the attached checklist please contact the reviewer as marked above. Remarks: CBOl3775 BUILDING 3 FEE'D AS COMMERCIAL CENTER. NO FEE'S ASSESSED ON THIS CB Tl PRESSED JUICERY Tl 1, ----------------------------------------------,rc Outstanding issues are marked with 1)~; • Please make the necessary corrections for compliance with applicable codes and standards and re-submit corrected plans and/or specifications to the division. Items that conform to permit requirements are marked with i -or-have intentionally been left blank. 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: [1 ] North arrow I I I Existing & proposed structures LLJ Property line dimensions [ : I Easements Show on site plan: Drainage patterns Existing & proposed slopes Existing topography Retaining Walls (location and height) Indicate what will happen with soil excavated from pool area. 1225 SF JUICERY Include on title sheet: Lot I Map No.: Legal description/lot number [7"] For all com~ercial/industrial building and tenant improvements, include: total building square footage with the square footage fore each different use, showing square footage of different uses (manufacturing, storage, warehouse, office, etc.) Example: 10,900 sf of SHELL to 10,900 sf OFFICE 7,000 sf of SHELL to 7,000 sf STORAGE 3,900 sf of SHELL to 3900 sf MANUFACTURING LOT 3 MAP 13997 SubdivisionfTract: CT 92-08 GREEN VALLEY Reference No(s): E-37 Page 2 of4 REVG/2012 -· ' \ \ PRESSED JUICERY Tl 1 N/A Attachments: E-37 2. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 11.06.030 of the Municipal Code. Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be included on the plans. If no grading is proposed write: "NO GRADING" Minor Grading Permit required. NOTE: The grading permit must be issued and grading approval obtained prior to issuance of a building permit. A separate grading plan prepared. a registered civil engineer must be submitted together with the completed application form attached. Graded Pad Certification required. All required documentation must be provided to your Construction Management & Inspection division inspector, . The inspector will then provide the Land Development Engineering counter with a release for the building permit. See attached checklist for minimum submittal requirements. 3. MISCELLANEOUS PERMITS RIGHT -OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. A separate right-of-way issued by the engineering division is required for the following: N/A Engineering Application Storm Water Form Right-of-Way Application/Info .f Reference Documents Page 3 of 4 REVS/2012 .. ***THIS CALCULATION WORKSHEET IS NOT ALL-INCLUSIVE OF FEES THAT MAY BE DUE FOR THIS PROJECT*** Prepared by: Address: Fees Update by: Fee Calculation Worksheet ENGINEERING DIVISION Date: GEO DATA:LFMZ: Bldg. Permit#: Date: Fees Update by: Date: EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's: Types of Use: Types of Use: Types of Use: Sq. Ft./Units Sq.Ft./Units Sq.Ft./Units ADT CALCULATIONS: List types and square footages for all uses. EDU's: EDU's: EDU's: Types of Use: Sq.Ft./Units ADT's: Types of Use: Types of Use: Types of Use: FEES REQUIRED: Sq.Ft./Units Sq. Ft./Units Sq. Ft./Units ADT's: ADT's: ADT's: /B&T: Within CFD:!Z]YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) ONO 1. PARK-IN-LIEU FEE: 0NW QUADRANT NE QUADRANT 0SE QUADARANT 0SW QUADRANT ADT'S/UNITS: I X FEE/ADT: I =$ 2.TRAFFIC IMPACT FEE: ADT'S/UNITS: I X FEE/ADT: I =$ 3. BRIDGE & THOROUGHFARE FEE: DIST. #1 0DIST.#2 DIST.#3 ADT'S/UNITS: I X FEE/ADT: I =$ 4. FACILITIES MANAGEMENT FEE ZONE: ADT'S/UNITS: IX FEE/SQ.FT./UNIT: I =s 5. SEWER FEE EDU's IX FEE/EDU: I =s BENEFIT AREA: EDU's IX FEE/EDU: I =s 6. DRAINAGE FEES: PLDA: []HIGH MEDIUM []LOW ACRES: IX FEE/AC: I =s 7. POTABLE WATER FEES: UNITS CODE CONN. FEE METER FEE SDCWAFEE TOTAL • PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 DATE: 7/19/16 PROJECT NAME: T.l. PROJECT ID: Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov PLAN CHECK NO: CB162763 SET#: ADDRESS: 1923 CALLE BARCELONA #169 APN: ~ This plan check review is complete and has been *CONDITIONALLY APPROVED (SEE REMARKS BELOW) by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required DYes IZ! No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: ROB.CICHOCKI@PRESSEDJUICERY.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: D Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov D Veronica Morones 760-602-4619 Veronica.Morones@carlsbadca.gov D Chris Glassen 760-602-2784 Christopher.Giassen@carlsbadca.gov D VaiRay Marshall 760-602-27 41 VaiRay.Marshall@carlsbadca.gov D Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov D Greg Ryan 760-602-4663 Gregory.Ryan@carlsbadca.gov D CindyWong 760-602-4662 Cynthia.Wong@carlsbadca.gov D Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: PLEASE WRITE ON SHEET A2.3 THAT THE BLADE & WALL SIGNS WILL BE UNDER SEPARATE PERMIT. Janet Altar From: Sent: To: Cc: Subject: Good morning, Amber Ressmer Wednesday, July 20, 2016 9:39AM rob.cichocki@pressedjuicery.com Building CB162763 Pressed Juicery plan does not require Carlsbad Fire Dept. plan review You are receiving this email because you are the applicant on the permit #CB162763 'Pressed Juicery' for 1923 Calle Barcelona, Ste. 169 in Carlsbad, CA. The fire marshal has determined that the fire department does not need to review these plans and no fire inspection is necessary. Thank you, Amber Ccicyof Carlsbad Amber Ressmer Administrative Assistant Fire Prevention City of Carlsbad 1635 Faraday Ave Carlsbad, CA 92008-7314 www.carlsbadca.gov p 760-602-4665 I F 760-602-8561 1 SIEMENS Title 24 Compliant P2 Lighting Panel Customizable lighting panels to meet various Disaggregation requirements California Title 24 and other Disaggregation Solutions Siemens has designed an easy to install compact solution with CT Provisions for metering segregated loads within P2 Panels with up to 400A bus in a 20" wide x 7.75" deep Type 1 or NEMA 3R enclosure. Many advantages can be seen below: • Compact CT Provision-fits in only 3" of unit space. • Easy to group loads as needed. -Nearly unlimited configuration design possibilities within P2 size constraints up to 74" high Enclosure. • Easy to Configure and order in COM PAS. -Support for multiple CT provisions within one enclosure, plus Feed-thru or Sub-feed capability to monitor more Load groups in a second or third enclosure when needed. • Easy to install split CT's on bus up to 400A. -Same 400A CT's can be used for bus and line side monitoring, as well as for Feed-thru and sub-feed monitoring. (other SEM3 CT's available for cable mounting as needed.) • Easy to select and install fronts for Type 1 panels-uses same fronts as standard P2 panels. www.usa.siemens.com/panelboards Designation(s): Example 1 1 BL 1 ~OA/1P 3 BL 3~0A/1P 5 BL &[2oAJ1P 7 BL 7~0A/1P 9 BL 9 ~OA/1P 11 BL 11 ~OA/1P 13 BL 13 20A/1P 15 BL 1& ~OA/1P 17 BL 17 ~OA/1P 19 BL 19 ~OA/1P 50 21 BL 21 120A/1P 23 BL 23 ~OA/1P 25 27 .0 27 29 31 BL 2& 120A/1P 33 BL 27 ~OA/1P 35 BL 29 ~OA/1P 37 BL 31 ~OA/1P 39 BL 33 12oAJ1P 41 BL 3& 20A/1P 43 BL 37 20A/1P 45 BL 39 20A/1P 47 BL 41 20A/1P 49 BL 43 20A/1P 51 BL 4& 20A11P 53 BL 47 20A/1P 7.75 Deep 2 l~Aj A ~OAI1P 2 BL .. ~OA/1P 4 BL ..; .... ~OAI1P I BL S2 ~OA/1P 8 BL .. ~OAI1P 10 BL ..; .... ~OA/1P 12 BL S2 i20AJ1P 14 BL ~OA/1P .. 1& BL ..; .... ~OA/1P 18 BL S2 ~OA/1P 20 BL .. i20AJ1P 22 BL ..; .... ~OA/1P 24 BL S2 ::; CT PROVISION ~ t; i20AJ1P 26 BL ~OA/1P '=! 28 BL .. .... ~OA/1P 30 BL S2 ~OA/1P 32 BL 0 i20AJ1P 34 BL ..; .... ~OA/1P 3& BL S2 ~OAI1P 38 BL 0 ~OAI1P 40 BL ..; i20AJ1P 42 BL ~ ~AI1P 44 BL 0 ~OAI1P 46 BL ..; .... ~OA/1P 48 BL S2 20.0 --~ 2* 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 PANELBOARD NOTES SECTION :1 OF1 PANEL TYPE :P2 CATALOG NUMBER :P2C54ML250ATS ENCLOSURE :11ndoor SYSTEM VOLTAGE :208Y/120 31114W Wyo AC IRRATING :10KAIC MAIN BUS :250A BUS MATERIAL :Aluminum Tin FEED :Top MOUNTING :Surface SELABEL :No SERIES RATED :No CONDUIT AREA :NIA "INDICATES POSITIONING NUMBERS TO HELP lMTH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW PANELBOARD COMPONENTS Main: 1 -250A MAIN LUG 1~1)fi6-350Kcmil Branches: 48-20A /1P-BL Options: 1-7.75" Deep Enclosure 1-Card Holder.Std Plastic Sleeve 1-NP Locotion-Trim 1-Certllication -UL 1-Std AIICu Gnd Connector 1~T Provision 1-Title 24 Compliant BL 20A/1P 1 BL 20A/1P 3 BL 20A/1P 5 BL 20A/1P 7 BL 20A/1P 9 BL 20A/1P 11 BL 20A/1P 13 BL 20A/1P 15 BL 20A/1P 17 BL 20A/1P 19 BL 20A/1P 21 BL 20A/1P 23 BL 20A/1P 25 BL 20A/1P 27 BL 20A/1P 29 BL 20A/1P 31 BL 20A/1P 33 BL 20A/1P 35 BL 20A/1P 37 BL 20A/1P 39 BL 20A/1P 41 BL 20A/1P 43 BL 20A/1P 45 BL 20A/1P 47 250A (1)#6-350KCMIUPH AND N I \ ~I I ~ ~~ A ~~ B ~~ ~~ A ~~ B ~~ ~~ A B ~~ ~~ ~~ A B ~~ ~~ ~~ A ~~ B ~~ ~~ A B ~~ ~~ ~~ A ~~ B ~~ ~~ A ~~ B ~~ c c c c c c c c v ~---72 4 BL 20A/1P BL 20AI1P BL 20A/1P BL 20A/1P ~~6 ~~8 ~1 ~~1 ~1 ~~1 ~~1 ~2 ~2 ~~2 CTPR 0 BL 20A/1P 2 BL 20A/1P 4 BL 20A/1P 6 BL 20A/1P 8 BL 20A/1P 0 BL 20A/1P 2 BL 20A/1P 4 BL 20A/1P OVISION ~2 6 BL 20A/1P 8 BL 20A/1P 0 BL 20A/1P 2 BL 20A/1P 4 BL 20A/1P 6 BL 20A/1P 8 BL 20A/1P ~~2 ~~3 ~3 ~3 ~~3 ~~3 ~~ ~~4 40 BL 20A/1P 2 BL 20A/1P 44 BL 20A/1P 6 BL 20A/1P 48 BL 20A/1P ~~ ~~4 ~ PANELBOARD NOTES SECTION :10F1 PANEL TYPE :P2 CATALOG NUMBER :P2C54ML250ATS ENCLOSURE :11ndoor SYSTEM VOLTAGE :208Y/120 3/114WWye AC IRRATING :10KAIC MAIN BUS :250A BUS MATERIAL :Aluminum Tin FEED :Top MOUNTING :Surface SELABEL :No SERIES RATED :No CONDUIT AREA :NIA "INDICATES POSITIONING NUMBERS TO HELP WITH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW ABBREVIATIONS 'MLO' MAIN LUGS ONLY 3 Designation(s): Example 2 MAIN JXD2 400A/3P ~ BL 'I16A11P I -~6A/1P 3 BL •I16A11P I ~6A/1P 5 BL &~6A/1P l i1&AJ1P 7 68 9 CT PROVISION 11 13 BL 7~0A/1P I ~A/1P 15 BL •50AI1P l J20A/1P 17 BL11~A/1P l ~OA/1P 19 21 CT PROVISION 23 25 7.0 27 l~~·~ 29 QJ214 31 33 1& 35 2 37 39 T~~·J 41 QJ217 43 45 18 47 49 51 CT PROVISION ~ 7.75 Deep 20.0 4 I• BL I• BL ls BL I• BL I1D BL l12 BL ::: 1-i! :1 i t; ::: 1-i! :1 i t; : 1-i! : 1-i! :1 t; 2* 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 45 48 50 52 54 PANELBOARD NOTES SECTION :1 OF1 PANEL TYPE :P2 CATALOG NUMBER :P2C18JD400ATS ENCLOSURE :11ndoor SYSTEM VOLTAGE :208Y/120 31!1 4W Wye AC IRRATING :10 KAIC MAIN BUS :400A BUS MATERIAL :Aluminum Tin FEED :Top MOUNTING :Surface SELABEL :No SERIES RATED :No CONDUIT AREA :N/A *INDICATES POSITIONING NUMBERS TO HELP WITH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW PANELBOARD COMPONENTS Main: 1 -400A /3P-JXD2 MAIN BREAKER 1-(2)3/0-500Kcmll Cu/4/0-500 AI Branches: 6 -15A /1P-BL 6 -20A /1 P-BL 2 -175A /3P-QJ2 Options: 1-7.75"" Deep Enclosure 1-Card Holder-Std Plastic Sleeve 1-NP Location-Trtm 1-Certlftcatton -UL 1-Std AI/Cu Gnd Connector 3-CT Provision 1-Title 24 Compliant (2)3/0-SOOKCMIL CU/ 410-500 AUPH AND N BL 15A/1P BL 15A/1P BL 15A/1P BL 20A/1P BL 20A/1P BL 20A/1P QJ2175A/3P QJ2175A/3P \1 1~ 3~~ 5~ 7~ 9~~ 1~~ 3~r-4~ ~ 5~ ~ 6---'7r-7 ---'7 ~ 8 ---'7 '---- A B c A B c At- +'!-t-c At- +'!- t-c ~ ~ -:72 ~---'74 BL 15A/1P BL 15AJ1P BL 15AJ1P ---'7 6 CTPR OVISION ~8 BL 20A/1P BL 20A/1P BL 20A/1P ---'71 ~---'71 CTPR OVISION CTPR OVISION PANELBOARD NOTES SECTION :1 OF1 PANEL TYPE :P2 CATALOG NUMBER :P2C18JD400ATS ENCLOSURE :11ndoor SYSTEM VOLTAGE :208Y/120 31!1 4WWye AC IRRATING :10KAIC MAIN BUS :400A BUS MATERIAL :Aluminum Tin FEED :Top MOUNTING :Surface SE LABEL :No SERIESRATED :No CONDUIT AREA :N/A "INDICATES POSITIONING NUMBERS TO HELP WITH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW ABBREVIATIONS 5 Designation(s): Example 3 MAIN FXD6 250A/3P 1 BL 1~0AI1P ~OA/1P 3 BL 320A/1P OA/1P 50 5 BL s~OA/1P riOA/1P 7 BL 7~0A/1P ~OA/1P 9 BL 9~0AI1P ~OA/1P 11 BL 11 20A/1P ~OA/1P 13 15 CT PROVISION 17 19 BL 13 ~OA/1P ~OA/1P 2 1.0 21 BL 15 ~OA/1P riOA/1P 23 BL 17 20A/1P ~OA/1P 25 BL 19 20A/1P ~OA/1P 27 BL 21 20AI1P ~J)A/1P 29 BL 23 20A/1P ~OA/1P 31 33 CT PROVISION 35 37 BL 25 20A/1P goAJ1P 39 BL 27 20A/1P ~OA/1P 41 BL 29 20A/1P ~A/1P 7.75 Deep 20.0 6 -------------·--~,~~"~"~ 2 BL 4 BL 6 BL 8 BL 10 BL 12 BL 14 BL 16 BL 18 BL 20 BL 22 BL 24 BL 26 BL 28 BL 30 BL 0 ,.; ~ C! .., 1-ii! ::l Ei "" .... 1-u 0 ,.; ~ 0 ,.; 1-ii! ::l ~ .... 1-u 0 ,.; 1-ii! 2* 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 PANELBOARD NOTES SECTION :1 OF1 PANEL TYPE :P2 CATALOG NUMBER :P2C30FX250A T5 ENCLOSURE :11ndoor SYSTEM VOLTAGE :208Y/120 3" 4WWye AC IRRATING :10KAIC MAIN BUS :250A BUS MATERIAL :Aluminum Tin FEED :Top MOUNTING :Surface SELABEL :No SERIES RATED :No CONDUIT AREA :N/A *INDICATES POSITIONING NUMBERS TO HELP WITH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW PANELBOARD COMPONENTS Main: 1 -250A 13P-FXD6 MAIN BREAKER 1-{1 )16-350Kcmil Cu /14-350 AI Branches: 30 -20A /1 P-BL Options: 1-7.75" Deep Enclosure 1-Card Holder-Std Plastic Sleeve 1-NP Location-Trim 1-Certlllcation -UL 1-Std AI/Cu Gnd Connector 2-CT Provision 1-Totle 24 Compliant (1)#6-350KCMIL CUI #4-350 AUPH AND N FXD6 I 250A/3P >----- ~ '------- \1 BL 20A/1P 1~~ BL 20A/1P 3 BL 20A/1P 5 BL 20A/1P 7 BL 20A/1P 9 BL 20A/1P 11 -----7~ -----7~ -----7~ -----7~ -----7~ -----7~ -----7~ -----7~ -----7~ BL 20A/1P 13 BL 20A/1P 15 BL 20A/1P 17 BL 20A/1P 19 BL 20A/1P 2 BL 20A/1P 23 1 -----7~ BL 20A/1P 25 BL 20A/1P 27 BL 20A/1P 29 -----7~ -----7~ -----7~ -----7~ r- ~ A A A A ~I I \J 8 t--~ -----7 2 BL 20A/1P 4 BL 20A/1P BL 20A/1P BL 20A/1P c B c B c B c B c ~-----76 ~-----78 ~-----71 ~-----71 CTPR ~1 ~-----71 ~-----71 o BL 20A/1P 2 BL 20A/1P OVISION 4 BL 20A/1P 6 BL 20A/1P 8 BL 20A/1P ~-----7 ~-----7 ~-----7 20 BL 20A/1P 22 BL 20A/1P 24 BL 20A/1P CTPR OVISION ~-----7 ~-----7 ~-----7 26 BL 20A/1P 28 BL 20A/1P 30 BL 20A/1P PANELBOARD NOTES SECTION :10F1 PANEL TYPE :P2 CATALOG NUMBER :P2C30FX250ATS ENCLOSURE :11ndoor SYSTEM VOLTAGE :208Y/120 311 •w Wye AC IRRATING :10KAIC MAIN BUS :250A BUS MATERIAL :Aluminum Tin FEED :Top MOUNTING :Surface SELABEL :No SERIES RATED :No CONDUIT AREA :N/A "INDICATES POSITIONING NUMBERS TO HELP WITH THE MANUAL PLACEMENT OF BREAKERS ON THE MECHANICAL VIEW ABBREVIATIONS 7 Siemens P2 with Disaggregation Features Title 24 interiors are familiar P2 series with up to 400A AL or CU bus material. • Main Lug Only or Main Breaker Panels • Multiple CT provisions available. • Grouping Breakers for load monitoring is easy to configure in COM PAS • Feed-thru and Sub-feed capability for multiple panels if more circuits are needed • CT Provisions can be placed as needed within the unit space available including just after the Main. References P2 Cut Sheet: PBSS-20302-xxxx SEM3 Solutions Guide: PDBR-SEM3S-xxxx SEM3 Data Sheet: RPFL-SEMDS-xxxx Title 24 Panels use existing series of enclosures. • 7.75" deep box minimum required. • 20" or 24" Wide available • Height of Enclosures available: 26", 32", 38", 44", 50", 56", 62", 68" & 74" • Available in NEMA 1 & NEMA 3R • Standard P2 accessories can be used • Compatible with SEM3 series of Controllers and related modules. (use CT # 4LSF0400R only for Bus mounting) • See P2 Panel board Cut Sheet or SpeedFax for more details of standard features. ASHRAE90 .1-2013 requirements can be met using SEM3 and Title 24 Panels combined. Avoid the 3rd party CT issues by using approved SEM3 components and CT's. ELISE ROTHSCHILD Director DBA: Pressed Juicery QCountp of ~an lJBtego DEPARTMENT OF ENVIRONMENTAL HEALTH FOOD AND HOUSING DIVISION P.O. BOX 129261, SAN DIEGO, CA 92112-9261 Phone: (858) 505-6659 FAX: (858) 505-6824 1 (BOO) 253-9933 www.sdcdeh.org PLAN APPROVAL SHEET SITE: 1923 Calle Barcelona Ste 169 Carlsbad 92009 BUSSINESS OWNER: Pressed Juicery Plans are approved contingent upon the following: AMY HARBERT Assistant Director RECEIVED AUG~ 2016 CITY OF CARLSBAD BUILDING DIVISION DATE:S/18/16 PC #: FFPP-006985 1) Department of Environmental Health (DEH) stamped plans shall be maintained at the jobsite and available for review at the time of the inspection. 2) Changes to equipment layout, menu, or application must be submitted for approval. Changes made without approval will make the plan approval null and void. 3) Obtain local Building Department and all applicable agencies permits and approvals PRIOR TO FINAL INSPECTION AND APPROVAL TO OPERATE BY THIS DEPARTMENT. 4) All food and utensil-related equipment shall be certified to applicable sanitation standards by an ANSI accredited testing agency. 5) Upon completion of 60%-80% of construction, call (858) 505-6660 to schedule a preliminary inspection. In lieu of a plumbing inspection by DEH: a. Floor sinks shall be installed Yz exposed and equipped with an appropriate grill cover if no access is provided for cleaning. b. Drain lines shall slope W' per foot to gravity, shall not exceed 15' in length and shall terminate a minimum of 1" above the floor sink with a legal air gap. Drain lines shall not intercept walkways or door ways. c. No condensate drainage of any kind, including HV AC can drain to the mop sink. d. The entire floor surface must be sloped to the floor drains approximately 1/8 inch per foot or a four feet diameter depression that slopes I :50 (approximately lf4 inch per foot). e. Conduits of all types shall be installed within walls as practicable. When otherwise installed, they shall be mounted or enclosed in a chase so as to facilitate cleaning. 6) Owners and/or operators must pass an approved and accredited Food Safety Certification course. Proof of successful completion of this course is to be furnished at the final inspection. 7) At the time when the final inspection is requested, the facility shall have all utilities operational and all refrigeration shall have an ambient air temperature of 38"F or below and shall be equipped with a thermometer accurate to+/-TF in the warmest section of the unit. All equipment is to be in place and functional. 8) Seal all cracks, gaps and crevices in counters, cabinets, around metal flashing, sink backsplashes, around pipes and conduits with silicone sealant. 9) An Air Balance Report will be required at final inspection. 10) AN\tFOODPROCESSING AREAS MUST BE COMPLETELY ENCLOSED. OPERABLE WINDOWS, MOVEABLE \VALL PANELS,. GARAGE ROLL-UP DOORS, 0~ OTHER MEANS OF RENDERING FOOD PROCESSING AREAS NOT FULLY ENCLOSED ARE NOT APPROVED. Plans reviewed by Celeste Penn, REHS @ (858) 505-6660 Chris Cardwell, EHT @ (858) 505-6775 CALL (858) 505-6660 AT LEAST 10 WORKING DAYS IN ADVANCE TO SCHEDULE PRELIMENARY AND FINAL INSPECTIONS. A FINAL INSPECTION SHALL BE CONDUCTED AND AN ENVIRONMENTAL HEALTH PERMIT SHALL BE ISSUED PRIOR TO OPENING AND OPERATING THIS FOOD ESTABLISHMENT. cc: File "Environmental and public health through leadership, partnership and science"