Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1925 CALLE BARCELONA; 162; PC070015; Permit
07-24-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No PC070015 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Valuation Reference # Project Title 1925 CALLE BARCELONA CBADSt 162 PLANCK 2550120400 SO 00 Lot# Construction Type Status PENDING Applied 02/13/2007 RMA CHICOS-REMODEL &EXPAND IN TO STE 162 TO CREATE SOMA-6447 SF TOTAL, REMAIN SEP Entered By Plan Approved Issued Inspect Area Applicant ESWARD QUINN 2413 PACIFIC COAST HWY LOMITA CA 90717 310606-2078 CT 101 Owner BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L C/O DELOITTE TAX LLP PO BOX 131071 CARLSBAD CA 92013 Plan Check Fee Additional Fees S10000 $000 Total Fees $100 00 Total Payments To Date $10000 Balance Due SO 00 BUILDING PLANS STORAGE ATTACHED Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 07-24-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB070422 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1925 CALLE BARCELONA CBADSt 161 Tl Sub Type 2550120400 Lot # S141,505 00 Construction Type Reference # CHICOS 4043 SF REMOVE DEMISING WALL.REMOD STOCKRM.BATHRM COMM 0 NEW Applicant QIUNN EDWARD 2413 PACIFIC COAST HWY LOMITA CA 90717 310-606-2078 Status FINAL Applied 02/14/2007 Entered By KG Plan Approved 03/27/2007 Issued 03/27/2007 Inspect Area TP Plan Check# Owner BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L C/O DELOITTE TAX LLP POBOX 131071 CARLSBAD CA 92013 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee S675 92 Meter Size $0 00 Add'l Reel Water Con Fee $439 35 Meter Fee SO 00 SDCWA Fee SO 00 CFD Payoff Fee S2972 PFF (3105540) SO 00 PFF (4305540) SO 00 License Tax (3104193) $0 00 License Tax (4304193) $0 00 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL SO 00 ELECTRICAL TOTAL SO 00 MECHANICAL TOTAL SO 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee SO 00 Additional Fees HMP Fee TOTAL PERMIT FEES SO 00 SO 00 $000 $000 $000 $000 $000 $000 $000 $000 S2700 $72 50 $2400 SO 00 SO 00 $000 $000 99 $1,26849 Total Fees $1,268 49 Total Payments To Date $1,26849 Balance Due $000 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" ol fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 07-24-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB070423 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1925 CALLE BARCELONA CBADSt 162 Tl Sub Type 2550120400 Lot# $84,14000 Construction Type Reference # SOMA 2404 SF REMOVE DEMISING WALL/REMOD STOCKRM.BATHRM COMM 0 NEW Applicant QUINN EDWARD 2413 PACIFIC COAST HWY LOMITACA 90717 310-606-2078 Status FINAL Applied 02/14/2007 Entered By KG Plan Approved 03/27/2007 Issued 03/27/2007 Inspect Area PD Plan Checktt Owner BORDERS INC <LF> FOURTH QUARTER PROPERTIES XXX L C/O DELOITTE TAX LLP PO BOX 131071 CARLSBAD CA 92013 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $488 81 Meter Size $0 00 Add'l Reel Water Con Fee $31773 Meter Fee $0 00 SDCWA Fee SO 00 CFD Payoff Fee S1767 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $000 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL SO 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee SO 00 Redev Parking Fee SO 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 SO 00 $000 $000 $000 $000 $000 $7600 $2000 $3050 $000 $000 $000 $000 97 $950 71 Total Fees $950 71 Total Payments To Date $950 71 Balance Due $000 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition" of fees dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to wrvch the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT •\635 Faraday Ave , Carlsbad, CA 92008 1 PROJECXINFORMATION FOR OFFICE USE ONLY PLAN CHECK NO /U O EST VAL Plan Ck Deposit Validated^ Date AddressTinclude Bldg/SuiteY)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use Proposed Use Name(jfl|t0'5 ^6^3 V S^/VI & AddressQfJO */ 9 CltV 3 APPLICANT^ ;E] Contractor, • Q ^pnt for Contractor Q Owner D Agent for Owner;i State/Zip SA, Fax* Name 4 PROPERTY OWNER Address State/Z Address City State/Zip Telephone #Name 5. CONTRACTOR; COMPANY NliVJVdt^ .1.1. ' • "JV IXl 1.11 ' '"'!' " :•" (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption/^ny violation) of Seetreni7031 5'by afj!V applicant for a permit subjects the applicant to a civil jDenaJty of nol more than five hundred dollars I $5001) '/ / -+\ iGnQ JlJi uoeff^ T. A/(°. WO I iv 1CM^ <M S-ftf C-<^> -&LU- ^ Name State L,cense# ^'/ CD <~f Address License Class City State/Zip City Business License # Telephone # Address City State/Zip TelephoneDesigner Name State License # _ 6. WORKERS1 COMPENSATION .. ; ,:;^ ',„,: .Jp' "; ; ' ; _-*>. .Jl^Sr' ,. '-....;,. :' '"':-:. , i:,.: ySi^- . Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations r]/l have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance "of the work for which this permit is issued [~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's c/wflpensatidn instance carrier and policy number are , . fe- I ~O?tannc. C.mp,n»Pol,., No Ex.,.,,.. D... (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) l~l CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000). in addifrprf~to4he cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees SIGNATURE M.y & llUMJQJU ~ DATE 1 Q 1 ~ O 7 ^ OWNER-BUILDER\DECLARATION ~~~ ..•.'•~..'?:" _ W; :: I hereby affirm that I ali exempt from the Contractor s License Law for the following reason L~D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) [~l I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES r~)NO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE .CJ>MPLEfETHIS'"slCJld>l^ ,: ...JMii: I'l" ..:.' -,5I: * ": :'""- 11, .'••'•J' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES L~] NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES d NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? [D YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT 8, CONSTRUCTION LENDING AGENCY ' ,,.,:.^3p!l' , .,.,:- '""•,... ' ;%- :„„: •'•"'* I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code) LENDER'S NAME LENDER'S ADDRESS :9.: APPLICAiMf.CERTiFIC/S;flbN :: ' : . •• " . ...... '.,j^\:.. .;>;»- ;^!!f!^ ",:L "•§:.. ' •—;•. I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 1 80 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced,for a period of 180 days (Section 106 4 4 Uniform Building Code) APPLICANT'S SIGNATURE DATE WHITE File YELLOW Applicant PINK Finance EsGil Corporation In Partnership witH government for Quitting Safety DATE 3/12/O7 Q APPLICANT a JURIS JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO/ PC07-0015 SET II PROJECT ADDRESS 1925 Calle Barcelona Suite 161 PROJECT NAME Chico's - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to X] Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone #• Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By. Doug Moody Enclosures Esgil Corporation D GA D MB D EJ n PC 3/5/07 Irnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 — ^Sg^g^ EsGil Corporation /n fartnersKip witA government for <BuiCtfing Safety DATE 2/21/07 ClABPUCANT JURISDICTION. City of Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO. PCO7-0015 SET I PROJECT ADDRESS 1925 Calle Barcelona Suite 161 PROJECT NAME Chico's - TI i i The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff [~~| The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck [X] The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Edward Quinn 2413 Pacific Coast Hwy, Lomita, CA 90717 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted. Edward Quinn Telephone # 310-606-2078 ext 101 Date contacted 2/^//?7(b*v^ Fax # 3f 0- (e> 0(t> ~-3> O' Mail Telephone \fFax:/ In Person REMARKS By Doug Moody Enclosures Esgil Corporation D GA D MB D EJ D PC 2/15/07 tmsmtldot 9320 Chesapeake Dnve, Suite 208 *• San Diego, California 92123 4> (858)560-1468 4 Fax (858) 560-1576 City of Carlsbad PC07-0015 2/21/O7 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO PC07-0015 OCCUPANCY M TYPE OF CONSTRUCTION: UN ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION- 2/13/07 DATE INITIAL PLAN REVIEW COMPLETED 2/21/07 JURISDICTION City of Carlsbad USE Retail ACTUAL AREA 6447sf STORIES 1 HEIGHT OCCUPANT LOAD 178 DATE PLANS RECEIVED BY ESGIL CORPORATION 2/15/07 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot City of Carlsbad PCO7-0015 2/21/07 Please make all corrections on the onginal tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Dnve, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1. Provide a section view of all new interior partitions Show a) Method of attaching top plates to structure b) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing 2 In areas where the occupant load is at least 50 sales room 105, two exits are required See Stores Table 10-A 3 Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served Section 1004.2 4 4 If exit signs are required, provide the following notes on the plans, per Section 1003282 a) Exit signs shall be located as necessary to clearly indicate the direction of egress travel No point shall be more than 100 feet from the nearest visible sign. b) Exit signs shall be readily visible from any direction of approach. 5 Please provide exit signs directing the occupants to the required exits Please show an exit sign at the opening between sales room 105 and front room 100 and between feature room 101 and sun room 102 6 When more than one exit is required, the exit access shall be arranged such that there are no dead ends in hallways more than 20' in length Section 1004 2.6. 7 Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support and attachment of the stockroom shelving Include all calculations and finding on the plans Please include the California license number, seal, date of license expiration and date plans are signed Business and Professions Code City of Carlsbad PCO7-OO15 2/21/07 8 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restncted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 9 The floor drain does not have a basin designed to prevent splashing from drain lines mdirected to the floor dram. UPC, Section 804.1 Please revise the plumbing plans to show the indirect waste from the water heater to discharge to an approved fixture such as a floor sink 804.1 of the UPC 10 Show that water heater is adequately braced to resist seismic forces Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank) UPC, Section 510 5. 11. Note that the doorways leading to sanitary facilities shall be identified, per Section 1115B 5, as follows a) An equilateral tnangle %" thick with edges 12" long and a vortex pointing upward at men's rest rooms b) A circle Vi" thick, 12" in diameter at women's rest rooms c) A 12" diameter circle with a tnangle supenmposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60" e) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per Section 1117B57. 12 Show that accessible lavatones comply with the following, per Sections 1115B212 a) When lavatones are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall b) The counter top is <34" maximum above the floor c) >29" high, reducing to 27" at a point located 8" back from the front edge d) >9" high x 30" wide and 17" deep at the bottom e) Hot water pipes and drain lines are insulated 13 Show that grab bars comply with the following, per Section 1115B 8 a) They shall be securely attached 33" above the floor, and parallel. NOTE Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36" City of Carlsbad PCO7-0015 2/21/07 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate. Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad PCO7-O015 2/21/07 VALUATION AND PLAN CHECK FEE JURISDICTION- City of Carlsbad PLAN CHECK NO PC07-OO15 PREPARED BY Doug Moody DATE 2/21/O7 BUILDING ADDRESS 1925 Calle Barcelona Suite 161 BUILDING OCCUPANCY- M TYPE OF CONSTRUCTION UN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 6447 cb Valuation Multiplier 3437 By Ordinance Reg Mod VALUE ($) 221,583 221,583 Bldg Permit Fee by Ordinance ; ^ Plan Check Fee by Ordinance Type of Review D Repetitive FeeRepeats Complete Review D Other r-i Hourly Structural Only Hour* Esgll Plan Review Fee $922 321 $599.51 $516.50 Comments Sheet 1 of 1 macvalue doc PLANNING/ENGINEERING APPROVALS fc. PERMIT NUMBER CB ADDRESS DATE RESIDENTIAL RESIDENTIAL ADDITION MINOR « $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Docs/Mlsforms/piannlng Engineering Approvals D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. OB i ^ C^ U / ~ Planner ^Erin Bndres APN: Tvoe of Project & Use: "~fl Zoning- General Plan: CFD (In/out) # Date of participation. l^> Address TV^b C PW ^ .r*A££lC*^.. Phone r760^ 602- 4625 }(^\ I. I Net Project Densitv: DU/AC Facilities Management Zone: Remaining net dev acres Glide One Legend: E3 Item Complete i Q Environmental Review Required: DATE OF COMPLETION: (For non-residential development. Type of land used created by this permit: ) Incomplete - Needs your action YES NO _ TYPE Compliance with conditions of approval? If not state conditions which require action. Conditions of Approval: _ Discretionary Action Required: APPROVAL/RESO. NO _ PROJECT NO _ YES NO. DATE TYPE OTHER RELATED CASES' Compliance with conditions or approval? If not state conditions which require action. Conditions of Approval: D Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES NO If California Coastal Commission Authority. Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Folkm-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required* (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed D Incluslonary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H \ADMIN\COUNTER\BldQPInchkRevChkW Rev 9/01 J3DD Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show. North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, nght-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 2 Provide legal description of property and assessor's parcel number. Policy 44- Neighborhood Architectural Design Guidelines 1 Applicability YES NO 2 Project complies YES NO_ ^DD Zoning: 1. Setbacks: Front Interior Side: Street Side: Rear Top of slope: 2. Accessory structure seti Front Interior Side. Street Side: Rear Structure separation1 3. Lot Coverage. Reauired Reauired Reauired Reauired Reauired racks. Reauired Reauired Reauired Reauired Reauired Reauired Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown ©aa /^> 4 Height Required. Spaces Required. Shown. Shown.5. Parking: (breakdown by uses for commercial and Industrial projects required) Residential Guest Spaces Required _ Shown _ screened bv an existing parapet wall or is new screening material required? Please see the attached handouts for examples. OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H \ADMlNVCOUNTER\BldgPlnchkRmChklst RevWOI Carlsbad Fire Department BLDG. DEPT COPY Plan Review Requirements Category PLANCK, Date of Report 02-15-2007 Name Address Reviewed by Permit # PC070015 Job Name CHICOS-REMODEL &EXPAND IN TO Job Address 1 925 CALLE BARCELONA CBAD St 162 The item you have submitted for review is adequately conduct carefully all commentS-attad^^PteBum and approval and/or standards Please review Conditions: Cond CON0001889 [MET] APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 02/15/2007 By MS Action AP 03-26-'07 14:53 FBOM-Russell Crane Chico's/Somas TEL 914-415-MOO FAX 314-415-2300 623-412-3666 T-372 P002/011 F-219 PERMIT READY TO ISSUE "Thft Ptanctevtt boon nvtawad for .JLJUUMS TOE_JLJWCTHCAL _JLJ*£nn*M.\JLJtUMWW iCA-Carisbad-Tha forums Location 1925 Barcelona Sto 161 & 162 J DATE: 03/26/2007 ARCHITECT flreVMon Architects CBOTWET PERMIT**: CB070422 CONSTRUCTION COST: .HotyMyOT CONTRACTOR: CMeo'a $141606 00 Sonus 584,140 00 (The Following Information a Per City Contact Laura Moore (760 «02.271») of th» Cariabad Building Department Buflding permit is ready to issue Penon obtaning the building permit should ateo verify tte procedure for obtaining any other permfto required for (his project IN ORDER TO PULL PERMIT: Building Dept reqtfires the roflowing1 "State Contractor's License •. "Check. Amount $2.219 20—Payeo City of Carlsbad (see following pages) "City Bu&inass License "Workers Compensation Insurance BUILDING DEPARTMENT ADDRESS City of Carlsbad 1635 Faraday Avenue Carlsbad CA 92008 PH 7606022719 The Permit wn be held for. «0 days after plan approval- Call immediately If pom* will not ba plowed up by above date. If you do not anticipate starting ihteprojeaforawMte.wereoommendthBtlh* pern* be picked up v«Uhm the new 30 days by one of the bhMlng contractors PLEAS* FORWARD THIS INFORMATION TO DESIGNATED GENERAL CONTRACTOR If you encounter any probMrrw or have any questions please contact Permits Direct at 310-606-2078 03-26-'07 14:56 FBOM-Bussell Crane 623-412-3666 T-372 P008/011 F-219 ASQBD. CERTIFICATE OF LIABILITY INSURANCE M£n*c4".AM« zniuranoe Oxrovp 464« B. V»n Buxw at. , 1200Vhoenix AB 85008 THltCBXTncATRIBItflJIDMAIlATTOtoT ONLV ANDCONFERO NO RRMffO UPON THE CBRTWCATE HOLDER. TH» C8RTWCATE DOM NOT AMBIO. CXTBND OR AITB« THE COVSRA6B AFFOBDBD BY THR POUCH! BBLOW. IKQURRUB AFraNUMa COVRRAM tuie* VUlev Ferae xaauxanc* Co.SOBOf NMMFRR-oUmnweMuUBraMM^r 20441 NMMftn NNJRRE: 204*4 COVERABE8 •»r >nimw(mumtcciKTFOm<M-tn^Fm^ i W'«««aeNr.iBW5eoc»mcHW*w«NW^OROTHWooaM^" >«B«le«»*CTTO*.TI«TB^.<WCU«l<>«/«JC3N>nrclWOFeoOM POUWNUMBW unit EKHXCURR1B*! 2084846881 ia/oa/o«12/01/07 PEP90WL4A9V HW WWWCIX-UMHU'MM « 1,000, 000 (200000 IS, 000 El ,000, 000 it, 000, 000 12.000,000 ANT/WO 2092806042 12/01/06 12/01/07 *i,ooo,aoo HREDAUKS OMWGBLNMJTV E«CH300IMI9iCe X iXXUt 12/01/06 12/01/07 10,000,000 110,000.000 3«WI>iMN 20I4B4OOO 13/01/04 12/01/07 • HBM»- KLRACHACCNg*1,000,000 - U BDHjOVZ 1,000,000 1,000,000 tollttUop XiUb 04/07/04 04/07/07 MOrMfttA 1,000,000 1, 000 < 000 A07-014 « AQ7-018, Cwlatad, o&; « ff«mB,RM Faxon |,1*4B calli* Barcelona, Ml XMUMd foe gra«x«l liability: Wwavn cuartor ropextiea 30 IAO « ibomu ant«cpxic«« lao, Chioo's nu xne c « AXO VtSiOB »IXCM»t 10 CHKlMCATBHOLOBR CANCBUATON oKtrooi Cbioo's m. Inc. UA BUbatdlWlM11216 HBtzo mrkwmyVt. o«nn«aw,TWMUMOM«uiw«wtt.iiNOi*viMnHM. 34* n«viWRITTEN N0tmie tw eemnoire HOUEK IWHSO ig TOH WFT, BUT BUUIM w M to ami ACOfMJ 29 (2aul«l)• ACORD CORPORATION 1MI KEEP ro« YOUR necoac« 1224016 OA rg ISSUED 3/6/2007 08 070G $80 IK. BAUANCfe PAID IN TAX ORDINANCE so ex WTh O CITY o^ CARLSBAD 03-26-'07 14:55 FROM-Russell Crane 623-412-3666 T-372 P007/011 F-219 gKJ<uu-i O w gC^ |HS 2*1 111|5I•s, p oe 1 UH orv: I •o 1 ftl :i QQQJ MuumoN WP9UM FMBH ITEMS ELCWOTON BENCHMARK l£ASE LINE EXISTING DEMISING PARTITION I I I I I + I-H4+ NEW DEMISING PARTITION ~^T~~!TmTZ EXISTING PARTITION NEW PARTITIONS TO CEILING NEW PARTITIONS TO DECK PARTITION OR MATERIAL TO BE REMOVED 1925 ( BUILDir CARl a CODES: BUUMO ENERGY: ELECTRICAL: 2001 CALJFORNIA BUILDING CODE 2001 CALIFORNIA PLUMBING CODE 2001 CALIFORNIA MECHANICAL CODE 2005 CALIFORNIA ENERGY CODE 2004 CALIFORNIA ELECTRICAL CODE CONSTRUCTION TYPE: II-B NON COMBUSTIBLE USE GROUP CLASSIFICATION: MERCANTILE OCCUPANCY CLASSIFICATION: BUUMO MERCANTILE TENANT MERCANTILE OCCUPANCY LOADS: SALES AREA STOCK AREA PIIIMU AREA MBC. AREA TOTAL 4513 SO FT DIVIDED BY 30 - 150 795 SO FT DIVIDED BY 300 - 2 904 SO FT. DIVIDED BY 300 - 3 235 SO FT DIVIDED BY 300 - 0 155 OCCUPANTS SQUARE FOOTAGE: SALES ABBA FITTING ROOMS SALES AREA SOMA FITTING ROOMS RESTROOU/HALUKAY STOCK ROOM TOTAL 795 SO 8447 SQ FT. FIRE SPRINKLER SYSTEM: YES 00 NOD FIRF A1ARU YESOt NOD 111tr w tf