Loading...
HomeMy WebLinkAbout1925 CALLE BARCELONA; 160 | 163 | 164 | 169; PC150014; Permit10-22-2015 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Permit No: PC150014 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: 1925 CALLE BARCELONA CBAD PLANCK 2550120400 Lot#: $0.00 Construction Type: THE FORUM- DIVIDE EXISTING 6000 SF SUITE(FORMERLY COLDWATER CREEK) INTO 4 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Applicant: STEVE KOHN STE 100 9320 CHESAPEAKE DR SAN DIEGO CA 92123 858-274-1812 Owner: T-C FORUM AT CARLSBAD LLC C/O TIAA-CREF 4675 MACARTHUR CT #1100 NEWPORT BEACH CA 92660 FINAL 03/23/2015 LSM 10/22/2015 05/22/2015 Plan Check Fee $400.00 Additional Fees $0.00 Total Fees: $400.00 Total Payments To Date: $400.00 Balance Due: $0.00 Inspector. FINAL APPROVAL Date: Clearance: NOTICE: Rease take NOTICE that approval of your prqject indudes the "Irrposition'' of fees, dedications, reservations, or ottier eactions hereafter odlectively refemed to as "fees'exactions." You have 90 days fliom the date this pernnit v«s issued to protest inrxasition of these f^ If you protest ttierri you must fdlcw tlie protest procedures set ferth in (3cK«fnment (2ate Sectioi 66020(a), and file the p(^^ processing in aooordanoe v«th Carlsbad IVlunicipal Code Section 3.3Z030. Failure to timely fdlcw that prooedure vwll bar any subsequert legal adion to attacK review, set aside, void, ar ami ttieir imposition. You are hereby FLRTHER NOTIRED that your right to protest ttie specified fees/esactions DOES NOT APPLY to water and seifler comection fees and capadty changes, na planning, zoning, grading or other similar application processing or servioe fees in connedion v«th this prqed. NOR DOES IT AF=PL.Y to any fees/exadions of w^'ch vou have previouslv been dven a NOTTCE amlar to this, or as to wfuch the statute of limtations has oreviouslv otherwise exdred. THE FOLLOWING APPROVALS REQUIRED PfilOR TO PERMIT ISSUANCE: {•PLANNING •ENGINEERING •BUILDING • FIRE nHEALTH • HAZMAT/APCD 1 City Of Ccirlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, GA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building(@carlsbadca.gov www.carlsbadca.gov Plan Check No. \ g'Q Q ^ Est. Value Plan Ck. Deposit I-ICCX VO Date iS I SWPPP JOB ADDRESS 1925 Calle Barcelona SUITE#/SPACE#/UNIT* 164 255 012 04 CT/PROJECT# # BEDROOMS # BATHROOMS TENANT BUSINESS NAME |\/ftg.ipai> CONSTR. TYPE DESCRIp-nON OF WORK: Incfude Square Feet ofAtfected Area(s) Demise an existing 6,000 SF retail suite (formerly occupied by Coldwater Creek) into 4 separate suites. Extend electrical and plumbing services, i.e. conduits, CW, and waste as needed. Add two new rooftop mechanical units so each space is separately conditioned. Modify building facade to accommodate new multi-tenant configuration • -^(f; -- -- r^r^rr-^-^ St ll PROpbsi EXISTING USE Retail ED USE Retail GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YES I |# NOj I AIRCONDITIONING YES QNO I I FIRESPRINKLERS YES I |NO| I APPUCANTNAME' ona UfhVcfamM Steven Kohn PROPERTY OWNER NAME T-C Forum at Carlsbad, LLC ADDRESS ADDRESS 1905 Calle Barcelona CITY Carlsbad STATE CA ZIP 92009 PHONE 760.479.0166 FAX 760.479.0170 EMAIL Rai.Chandanl@am.jll.com DESIGN PROFESSIONAL Kohn Architects, P.C. CONTRACTOR BUS. NAME-TN / ^ . ADDRESS 9320 Chesapeake Dr., Suite 100 ADDRESS CITY San Dieao STATE CA ZIP 92123 CITY TIAS»TI >^ STATE ZIP 858.274.1812 FAX 858.227.5720 PHONE EMAIL steven@),kohndesign.com EMAIL C26624 arf BUS. Lic.# (Sec. 7031.5 Business and Professions Code: Any City or County wiiicii requires a permit to construct, alter, innprove, demolisii or repair any structure, prior to its issuance, also requires tiie applicant for sucti permit to file a signed statement that tie is licensed pursuant to the provisions of tlie Contractor's License Law (Chapter 9, commending with Section '7000 of Division 3 of the Business and Professions Code) ortnat he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicantfor a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKERS' COMPENSATION Workers' Coinpensation Declaration: / herehy affirm under penalty of perjury one ofthe foltowing declarations: HI have and will maintain a ceftificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the perfomiance of the worl< for which this permit is issued. I have and will maintain workers' compensation, as reguired by Section 3700 of the Labor Gode, for the perfomiance of the worl< for which this perniit is issued. My workers' compensation insurance,carrier and policy number are: Insurance Co "BaOCX-tVfeJtl ^fO^A-tMry^ LP Cc2 Poiicv No CSTT'S'QQft^ I O Expiralion Date f 3\ jZx^]^ This section need not be completed if the permit is for one hundred dollars ($100) or less. I I Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNINQ: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), In addition to the cost of compensation, damages as pro^jjlsd^ in^ecti<2DJ2l''7]f the Labor code, interest and attorney's fees. JS^ CONTRACTOR SIGNATURE • AGENT DATE 3-. )sio// 7^ OWNER-BUILDER OECLARATION / herehy sffirm (haf / am exempt from Contractor's Ucense Law for the following reason: I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the stmcture is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Ucense Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I I I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for constnjction of the proposed property improvemenl Qves I iNo 2.1 (have / have not) signed an application for a building pennit for the proposed work. 3.1 have contracted with the following person (fimi) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of Ihe work, but I have hired the following person to coordinate, supervise and provide the major woris (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): >€S'PR0PERTY OWNER SIGNATURE QAGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a pemiit from the air pollution control district or air quality management district? Yes No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CO NSTRUCTION LENOING AGENCY I hereby affirm that there is a construdion lending agency for the performance of the vDork this permit is issued (Sec 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I certify that I have read ttie application and state thatthe above infbnnation Is conect and that the infoirtiation on ttie plans Is accurate. I agiee to comply with all City ordinances and State laws relating to building constmction. I hereby authorize representative of the City of Cartsbad to enter upon the above mentioned property lor inspection purposes, I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT, OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or constmction of stmctures over 3 stories in height, cial under the provisioi« ofthis Code shall expiie by limitation and become null and void if the building or wori< authorized by such pemiit e not commencsd within oik authorized W^iwwitjs suspended or abandoned at any time after the \wrt< is commenoed fbr a period of 180 days (Section 106,4.4 Unifonn Building Code). EXPIRATION: Every pennit issued by the Buildii 180 days from the date of such permit or if the APPUCANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final Inspection. Fax (760) 602-8560, Email buildinofScarlsbadca.QOV or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008. C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EIVIAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAILTO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL / FAX TO OTHER: ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ^APPUCANT'S SIGNATURE DATE To: Page 2 of 3 2015-06-16 19:28:34 (GMT) From: Henry Hill Hi HILL-INSPECTION TESTING / ENGINEERING June 16, 2015 City of Carlsbad Building Departinent 1635 FaTaday Avenue Carlsbad, Califomia 92008 Facsimile: (760) 602-8560 Reference: The Forum 160,163,164,169- 1926 Calle Barcelona, Carlsbad Permit Number CB150860,62.63,64 Subject: Special Inspection Affidavit Ladies and Gentlemen: This letter is to notiiy that; Special Inspections of Reinforced Concrete, Masonry, Structural Steel Welding, High Strength Bolting, Epoxy Anchor Installation, and Materials Testing are to be performed at the subject project by HiTE (Hill-irspectioa/Testing/Engineering). All work requiring special inspection and/or materials sampling and testing for the structure(s) constracted imder the referenced permit are to be performed in accordance with the approved plans, specifications, and changes thereto, and the Cahfomia Building Code. Respectfully submitted, HiTE Heniy Barton Hill, Principal Engineer M.S., P.E. #64822 Attachments: Principal Certifications PO Box 771, San Diego, CA 92038-0771 San Diego • Orange • Los Angeles • Riverside • Imperial • San Bemardmo www.h-ite.com • (858) 220-1078 Office • (858) 220-7421 Fax To: Page 3 of 3 2015-06-16 19:28:34 (GMT) From: Henry Hill nil M E nu Hanrylort.Hill,M.S. ft HiTE HILL - INSPECTION TESTING / ENGINEERING Office (858) 220-1078 Fax (858) 220-7421 hill(@h-ite.com Special Inspection Report Proyecf Address 1926 Calle Barcelona Building Pennit Number Jurisdiction / File Number CBI 50860,62,63,64 Carlsbad Pn>]ect Name The Forum 160,163,164, 169 Architect Design Build Construction Material , 169 Source Reinf Conc/Epoxy f c=2500 psi Engmeer Description of Materials ASTM A615 Grade 60 Reinforcing General Contractor PCGI Simpson Strong-Tie®, SET-XP Epoxy, ICC ESR-2508 Sub Contractor Sub Contractor Other Other Inspection Date / Start of Work /End of Work 13-Jun-15 Provided special inspection for the epoxy installation of (34) #6 dowel ancliors embedded a minimum of 6", into existing Grade Beam, per Sheet 8-4, Detail 5, at the referenced project. All holes were drilled using the correct drill bit size, and properly brushed/cleaned. Installation of anchors is in compliance with ICC ESR-2508, and manufactures specifications. I HEREBY CERTIFY THAT I HAVE INSPECTED THE ABOVE REPORTED WORK. UNLESS OTHERWISE NOTED, THE WORK INSPECTED IS TO THE BEST OF MY KNOWLEDGE IN COMPLIANCE WITH THE APPROVED|ii CONSTRUCTIOBN DOCUMENTS, AND APPLICABLE SECTIONS OF THE GOVERNING BUILDING LAWS. Henry Barton Hill, PE 64822 San Diego • Orange • Los Angeles • Riverside • San Bernardino EsGil Corporation In (Partners/tip with Qovemment for (BuiCcfing Safety DATE: 4/23/15 • APPLICANT • JURIS. JURISDICTION: CityofCarlsbad • PLAN REVIEWER • FILE PLANCHECKNO.: PC15-0014 SET II PROJECTADDRESS: 1925 Calle Barcelona Suite 164 PROJECT NAME: Landlord Demising Suites - TI The pians transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • MB • PC 4/16/15 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnersfiip witH government for (BuiCcCing Safety DATE: 4/3/15 •APPLICANT J3 JURIS. JURISDICTION: CityofCarlsbad / • PLANREVIEWER • FILE PLANCHECKNO.: PC15-0014 SETI PROJECTADDRESS: 1925 Calle Barcelona Suite 164 PROJECT NAME: Landlord Demising Suites - TI I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. X] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. IXI EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Steve Kohn Telephone #: 858-274-1812 Date contacted: - / (byC^K^) Email: steven@kohndesign.com ,£Maiiy Telephone X Person • REMARKS: By: Doug Moody Enclosures: EsGil Corporation • GA • EJ • MB • PC 3/26/15 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 CityofCarlsbad PC15-0014 4/3/15 PLAN REVIEW CORRECTION LIST TENANT IIVIPROVEIVIENTS PLANCHECKNO.: PC15-0014 JURISDICTION: City ofCarlsbad OCCUPANCY: M USE: Shell TYPE OF CONSTRUCTION: VB ACTUAL AREA: 5984sf ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: SPRINKLERS?: Yes OCCUPANT LOAD: N/A REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 2/23/15 DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/26/15 DATE INITIAL PLAN REVIEW COMPLETED: 4/3/15 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval ofthe plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. CityofCarlsbad PC15-0014 4/3/15 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Please provide S sheets for construction. 107.2, 3. Please have the engineer indicate ifthe lateral resisting system ofthe building will be affected by the alterations to the building exterior? If so how will the system re-enforced? 4. Please provide a door schedule; indicate the type of hardware and reference the doors on the floor plan. 5. Please review the requirements, revise the plans appropriately and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 6. Please clarify the plans, the corridor is shown to be a 1 hour rated corridor yet the corridor lid is not a 1 hour assembly? Corridor in a sprinklered building serving a M occupancy are not required to be 1 hour but ifthe plans identify the corridor to be Ihour it must comply. Revise the plans to show the lid assembly to be a 1 hour assembly or show the corridor to be non-rated. Section 107.2. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. CityofCarlsbad PC15-0014 4/3/15 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes • No • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. CityofCarlsbad PC15-0014 4/3/15 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: CityofCarlsbad PLANCHECKNO.: PC15-0014 PREPARED BY: Doug Moody DATE: 4/3/15 BUILDING ADDRESS: 1925 Calle Barcelona Suite 164 BUILDING OCCUPANCY: M BUILDING PORTION AREA (Sq.Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Tl 675 43.32 29,241 Air Conditioning Fire Sprinklers TOTAL VALUE 29,241 Jurisdction Code cb By Ordinance Bldg. Permt Fee by Ordinance Plan Oieck Fee by Ordinance Type of Review: Gl] Complete Review GU Repetitive Fee ^ Repeats • Other Q Hourly EsGil Fee • Structural Only Hr. @ $278.49 $181.02 $155.95 Comments: Sheet 1 of 1 macvalue.doc + PLAN CHECK Community & Economic CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 wv\/w.carlsbadca.gov DATE:03/25/2015 PROJECT NAIVIE: Tl COLDWATER CREEK TO 4 BUILDINGS PROJECTID: PC150014 PLANCHECKNO:! SET#: 1 ADDRESS: 1925 CALLE BARCELONA 164,60,63,69 APN: 255-01204 VALUATION: / This plan check review is complete and has been APPROVED by the ENGINEERING Division. By: VALRAY NELSON A Final Inspection by the ENGINEERING Division is required Yes /No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: STEVEN@KOHNDESIGN.COIVI You may a/so have corrections from one or more of t/ie d/V/s/ons /isted ibe/ow. Approva/ from tfiese divisions may be required prior to the issuance of a building permit. Resubmitted plans siiould indude corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PRiVENTliN 7i0^02-4665 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Greg Ryan 760-602-4663 Gregorv.Rvan@carlsbadca.gov Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.gov / ValRay Marshall 760-602-2773 ValRay.Marshall@carlsbadca.gov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for PC150014 Date: 03/25/2015 ProjectAddress: 1925 CALLE BARCELONA 164,60,63,69 APN: 255-012-04 Project Description: TI OF 6,000SF TO 4 INDIVIDUAL SUITES. RETAIL TO Valuation: RETAIL ENGINEERING Contact: VALRAY NELSON Phone: 760-602-2741 Email: VALRAY.MARSHALL@CARLSBADCA.GOV Fax: 760-602-1052 RESIDENTIAL INTERIOR / TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$20,000.00) PLAZA CAMINO REAL CARLSBAD PREMIER OUTLETS COMPLETE OFFICE BUILDING OTHER: GYM OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: VALRAY NELSON REIVIARKS: Tl OF 6000 SF BUILDING TO 4 SUITES DATE: 03/25/2015 E-36 Notification of Engineering APPROVAL has been sent to STEVEN(gKOHNDESIGN.COM viaVALRAY.MARSHALL@CARLSBADCA.GOV on 03/25/2015 Page 1 of 1 REV 4/30/11 Fee Calculation Worksheet ENGINEERING DIVISION Prepared by: Date: 03/25/2015 GEO DATA: LFMZ: / B&T: Address: 1925 CALLE BARCELONA 164,60,63,69 Bldg. Permit #: PCI 50014 Fees Update by: Date: 03/25/2015 Fees Update by: Date: 03/25/2^^5 EDU CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's Types of Use: Sq.Ft./Units EDU's ADT CALCULATIONS: List types and square footages for all uses. Types of Use: Sq.Ft./Units ADTs Types of Use: Sq.Ft./Units ADT's Types of Use: Sq.Ft./Units ADT's Types of Use: Sq.Ft./Units ADTs FEES REQUIRED: Within CFD: YES (no bridge & tfioroughfare fee in District #1, reduces Traffic Impact Fee) NO 1, PARK-IN-LIEU FEE: NW QUADRANT / NE QUADRANT SE QUADARANT SW QUADRANT ADTS/UNITS: X FEE/ADT: =$ • 2.TRAFFIC IMPACT FEE: • ADT'S/UNITS: X FEE/ADT: =$ • 3. BRIDGE & THOROUGHFARE FEE: DIST #1 DIST.#2 DIST.#3 ADT'S/UNITS: < FEE/ADT: =$ • 4. FACILITIES MANAGEMENT FEE ZONE: • ADTS/UNITS: X FEE/SQ.FT./UNIT: =$ • 5. SEWER FEE • EDU's X FEE/EDU: =$ • BENEFIT AREA: • EDU's X FEE/EDU: =$ • 6. DRAINAGE FEES: PLDA: HIGH MED' UM LOW ACRES: X FEE/AC: =$ • 7. POTABLE WATER FEES: UNITS CODE CONN. FEE METER FEE SDCWA FEE TOTAL CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.carlsbadca.eov DATE: 3-24-15 PROJECTNAME: PROJECTID: PLAN CHECK NO: PC 15-14 SET#: 1 ADDRESS: 1925 Calle Barcelona APN: 255-012-04-00 ^ This plan check review is complete and has been APPROVED by the Plannmg Division. By: Chris Sexton/Christer Westman A Final Inspection by the Planning Division is required • Yes ^ No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance ofa building permit. Resubmitted plans should include corrections from all divisions. Q This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: steven@kohndesign.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.gov [ i Chris Giassen 760^602-2784 Christopher.Glassen(a>ca rlsbadca.gov 1 j Greg Ryan 760-602-4663 GregorY.Ryan@carlsbadca.gov 1 1 Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.gov [j ValRay Marshall ' 750-602-2741 ValRav.IVlarshail@carlsbadca.gov [ J Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.^ov • Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca^ov Remarks: split one suite into four suites ^ CITY OF CARLSBAD PLAN CHECK REVIEW TRANSMITTAL Community & Economic Development Department 1635 FaradayAvenue Carlsbad CA 92008 www.carlsbadca.gov DATE: 03/31/l^PROJECT NAME: division of coid water PROJECT ID PLAN CHECK NO: pcl50014 SET#: I ADDRESS: 1925 calle ba iai«»£KjvpS)EPT COPY • This plan check review is complete and has been APPROVED by the flre Division. By: cwong A Final Inspection by the Division is required |^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to You may ateo have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the Issuance ofa building permit. Resubmitted plans should mclude corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked: :7 I I Chris Sexton 760-602-4624 Chris.Sexton@carlsbadca.^ov I I Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov I I Greg Ryan 760-602-4663 Gregofv.Rvan®carlsbadca.^ov I I Gina Ruiz 760-602-4675 Gina.Ruiz@carlsbadca.^ov I I Linda Ontiveros 760-602-2773 Linda.Ontiveros@carlsbadca.gov 3 Cindy Wong 760-602-4662 CYnthia.Wong@carlsbadca.gov • • I I Dominic Fieri 760-602-4664 Dominic.Fieri@carlsbadca.gov Remarks: **APPROVED: Page 1 of2 THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Page 2 of2 Carlsbadi Fire Department Plan Review ^equipemmts Categoiy: PLANCK, Date ofRgpQrt:O3-3i40iS Reviewed by: Name: Addr@§s: STSVE KOHK STE iOO 9320 CHESAPEAKE DR SANDIEGO CA §2123 Permit #: PCl SOOH Job Nan«: THE FORUM- DIVIDE EXISTING Job Address: 1925 CALLE BARCELONA CBAD TfirrtfiTri r ll rim itmni 3inaJaaffijiib||yi;^^^;|Be^^ office eamot adequately conduct a r-ir—tn Jiilii n'lflii r^mrlinnrr-"ith tli" H|"| III i' lii rnHrfj flnfiVr TtnnHnrfl" Please review carefuUy all eommgj3J»««ttS6E@d Please resubmit the neeessaiy plans and/or ijn i iln liiiilM >^iilli Jiiiiii i 'i "clouded", to this office foiroview and approvaL Cond; CON0Q08147 [MET] ** APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 03/31/2015 By: cwong Action: AP MESRI ENGINEERING STRUCTURAL CONSULTING PROJECT: FACADE REMODEL AT. 1925 CALLE BARCELONA. CARLSBAD, CA ROOF LOADS (FLAT): ROOFING 3.0 (NO GRAVEL) PLYWOOD 1.8 RAFTERS 3.0 CLG.-UNSULATION 3.0 SPRINKLER 2.0 MISC. 2.2 ROOF LOADS (SLPOED): MANSARDS / TOWERS ROOFING 12.0 PLYWOOD L8 RAFTERS 3.0 CLG. + INSULATION 0.0 SPRINKLER 0.0 MISC. 1.2 DEAD LOAD LIVE LOAD TOTAL LOAD 15.0 PSF DEAD LOAD 20.0 PSF LIVE LOAD 35.0 PSF TOTAL LOAD AT TOWERS ADD CLG LOAD, AND STUCCO AS REQllIRED-10.0 PSF WALHEXT.): Ih.O PSF WALL (INT.): 10.0 PSF 18.0 PSF BEAMS: #1 POSTS: #1 20.0 PSF 38.0 PSF JOIST & BL0CKING:#2 OR # I STUDS & PLATES: #2 0R#1 U.ON, ALL CONCRETE TO BE A MIN. OF 3000 PSI AT 28 DAYS STRENGTH. (SEE PLANS FOR SPECIAL INSPECTION REQUIREMENTS) Ss-1.089 Fa =1.064 Sms=I 159. Sds =0.773. R=6.5, 1=1.0. SfTE CLASS D, P=l .3 WIND: CBC2013 EXP. B, 110 MPII, 3 SBC GUST 0 SOIL PRESSURE: 1500 psf @ 18" BELOW GRADE BY: CBC MIN. THESE CALCULATIONS ARE NOT VALID OR USABLE WITHOUT THE WET SIGNATURE OF ONE OF THE PRINCIPALS OF THE MESRI ENGINEERING. THESE C ALCULATIONS ARE ONLY FOR THE ITEMS INCLUDED HEREIN. SPECIFIED BY THE CLIENT AND DO NOT IMPLY APPROVAL OF ANY OTHER PART OF THE STRUCTURE BY THIS OFFICE. JOBNO.: 0.001526 DATE: 03-13-15 DESIGNED BY: M.M CHECKED BY: PAGE: I 5/ Zl 34- H^^O^S(2^ 10'-- f^^SiT^As. 1^1 So ffrr 3 fiHG> X-o(L Sr^^ ^"^.m U)/vos Aoo^cp I (f^) \^^' Tii bG.^ -pfl^^^^ etc. TJ.BramfTM) 6.06 SarisI NumI User: 4 3/28^003 1:46:39 PM Pagel EngineVereion: 1.6.44 ANttyoranucr Buiinest imbar 7002112237 Type "B & B1" ~~ Load Case #1 14" TJI®/L65 @ 32" o/c THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED y\Member Slope: .4/12 Roof Slope.4/12 s All dimensions are horizontal. / LOADS: Analysis is for a Joist Member. Primary Load Group - Roof (psf): 20.0 Live at 125 % duration, 15.0 Dead •26'- Product Diagram is Conceptual. SUPPORTS: 1 Glulam or solid sawn lumber beam 2 Glulam or soiid sawn lumber beam Input Bearing Vertical Reactions (Ibs) Width Length Live/Dead/Uplift/Total 2.50" Hanger 667 / 500 / 0 /1167 2.50" Hanger 667/500/0/1167 Ply Depth 14.01" 14.01" Nailing Depth N/A N/A Detail Other Top Mount Hanger None Top Mount Hanger None HANGERS: Simpson Strong-Tie® Connectors Support Model Slope Top Mount Hanger V—/ Top Mount Hanger ITT314 ITr314 .4/12 .4/12 Skew 0 0 Reverse Flanges N/A N/A -Nailing for Support 1: Face: 2-10d , Top 4-10d . Member: 2-N10 •Nailing for Support 2: Face: 2-10d , Top 4-10d, Member: 2-N10 DESIGN CONTROLS: Support Wood Species Douglas Fir Douglas Fir U^ejus^ I Maximum Design Control Control Location Shear (Ibs) 1147 -1147 2656 Passed (43%) Rt. end Span 1 under Roof loading Vertical Reaction (Ibs) 1147 1147 2356 Passed (49%) Bearing 2 under Roof loading Moment (Ft-Lbs) 7052 7052 9569 Passed (74%) MID Span 1 under Roof loading Live Load Defl (in) 0.700 1.230 Passed (L/422) MID Span 1 under Roof loading Total Load Defl (in) 1.225 1.640 Passed (L/241) MID Span 1 under Roof loading -Deflection Criteria: MINIMUM(LLU240.TL:L/180). -Bracing(Lu): All compression edges (top and bottom) must be braced at 4' o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. PROJECT INFORMATION: The Forum At Carlsbad Building 2 Roof Carlsbad, CA SC02E02064 7\ OPERATOR INFORIVIATION: Steve Bennett Trus Joist 27042 Towne Centre Drive Suite 200 Foothill Ranch . CA 92610 Phone: 949-455-8252 Fax : 949-616-1616 bennetsa@trusjoist.com Ccpyrighc t; 2003 by Trus Joist, a Weyerhaauser Business TJIK and TJ-BeamK are registered trademarics of Trus Joist. e-I Joist**.Pro" and TJ-Pro** are tradenarks of Trus Joist. Simpson Strong-Tietfi Connectors is a registered tradenark of Simpson Strong-Tie Conpany, G:\TJCADD\JOB\5C02e02Oe4\Ossi9ns\Siting\PavBldg2\TypeB and BlLCl.sms SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY RECORD ID # HHMBP # BP DATE / / Business Name Business Contact Telephone # The Forum Cartsbad Shopping Center Ra) Chandani (760)479^)166 Project Adciress City State Zip Code APN# 1925 Calle Barcelona Carlsbad, California 92009 255-012-04 Mailing Address City State Zip Code Plan File# 190S Calle Barcelona, Suite 200 Carlsbad, Califomia 92009 Project Contact Telephone # The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: (not reauired for proiects within the Citv of San Diegol: Indicate bv circling the item, whether vour business vyill use, process, or store anv of the followina hazardous materials. If anv of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Occupancy Rating: Facility's Square Footage (including proposed project): 1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 2. Compressed Gases 6. Oxidizers 10. Cryogenics Flammable/Combustible Liquids Flammable Solids Pyrophorics Unstable Reactives 11. 12. Highly Toxic or Toxic Materials Radioactives 13. 14. 15. Corrosives Other Health Hazards None of These. YES NO 1. • E 2. • • 3. • 4. • El 5. • 6. • 7. • 8. • E] / Date Initials PART II: SAN DiEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISION fHMDl: If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overiand Avenue, Suite 170, San Diego, CA 92123. Call (858) 505-6700 prior to the issuance of a building permit. FEES ARE REQUIRED. Project Completion Date; Expected Date of Occupancy: ^ CalARP Exempt (for new construction or remodeling projects) Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Sutstances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500 pounds and/or 200 cubic feet? Will your business store or handle carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? Will your business store petroleum in tanks or containers at your facility with a total facility storage capacity equal to or grealer than 1,320 gallons? (California's Aboveground Petroleum Storage Act). • CalARP Required I Date Initials • CalARP Complete I Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT (APCDl: If the answer to Question #1 below is no or the answer to any of the Questions #2-5 is yes, applicant must cofrtact the APCD at 10124 Old Grove Road, San Diego, CA 92131-1649 or telephone (858) 586-2600 prior to the issuance of a building or demolition pemnit. If the answer to questions #4 or #5 is yes, applicant must also submit an asfciestos notification fonn to the APCD at least 10 wori<ing days prior to commencing demolition or renovation. (Some residential projects may be exempt from the notification requirements. Contact the APCD for more information.) YES • NO • • 3. • 4. • 5. • Has a survey been performed to determine the presence of /\sbestos Containing Materials? Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at hftgj7\w and the list of typical equipment requiring an APCD permit on the reverse side ofthis from. Contact APCD ifyou have any questions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located Viithin 1,000 feet ofthe outer boundary of a school (K through 12)? (Search the California School Directory at httc/Avww.cde.ca.aov/re/sd/ for public and private schools or contact the appropriate school district). Will there be renovation that involves handling of any friable asbestos materials, or dlsturialng any material that contains non-friable asbestos? Briefly describe business activities: Retail sales - Actual improvements of suites to be performed by future tenants Briefly describe proposed project: Sub-demising of a single retail suite into four suites and related facade remodel 1 declare under penalty of perjury that to the best of my knowledge and belief tt* e responses made herein are true and correct. / / Name of Owner or Authorized Agent Signature of Owner or Authorized Agent Date FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:. BY: DATE: EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASED FOR BUILDING PERMT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD Of *A Stamp in this box onlv exempts businesses from compieting or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply. HM-9171 (03/14) County of San Diego-DEH-Hazanious Materials Division City ofCarlsbad Permit No: Address Valuation Worksheet Assessor Parcel No. Date Building Division Type of Work Area of Work Multiplier VALUE SFD and Duplexes $132.05 $0.00 Residential Additions $157.88 $0.00 Remodels / Lofts* $68.98 $0.00 Apartments & Multi-family $117.70 $0.00 Garages/Sunrooms/Solariums $34.45 $0.00 Patio/Porch/Carport $11.48 $0.00 Enclosed Patio* $18.66 $0.00 Decks/Balconies/Stairs $18.66 $0.00 Retaining Walls, concrete,masonry $22.96 $0.00 Pools/Spas-Gunite $48.80 $0.00 Tl/Stores, Offices 1,263 $43.32 $54,713.16 Tl/Medlcal, restaurant, H occupancies $60.29 $0.00 Photovoltaic Systems/ # of panels $400.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fire Sprinkler System $3.73 $0.00 Air Conditioning - commercial $6.03 $0.00 Air Conditioning - residential $5.02 $0.00 Fireplace/ concrete, masonry $4,621.70 $0.00 Fireplace/ prefabricated Metal $3,141.89 $0.00 $0.00 $0.00 TOTAL Valuation: $54,713 Comm/Res (C/R): C Builciing Fee $427 61 Plan Check Fee $299 33 Strong Motion Fee $11 00 Green Bldg. Stand. Fee $1 00 Green Bldg PC Fee $150 00 License Tax/PFF $1,914 96 License Tax/PFF (in CFD) $995 78 CFD Isthourof Plan CheckFire Expedlte Plumbing Mechanical Electrical TBD TBD TBD $54,713.16 CFD 0 Yes (PFF= 1.82%) 0 No (PFF = 3.5%) Land Use: Density: Improve. Area: Fiscal Year: Annex. Year: Factor: CREDITS PFF and/orCFD Explanation: City ofCarlsbad Permit No: Address Valuation Worksheet Assessor Parcel No. Date By Building Division TypeofWork Area of Work Multiplier VALUE SFD and Duplexes $132.05 $0.00 Residential Additions $157.88 $0.00 Remodels / Lofts* $68.98 $0.00 Apartments & Multi-family $117.70 $0.00 Garages/Sunrooms/Solariums $34.45 $0.00 Patio/Porch/Carport $11.48 $0.00 Enclosed Patio* $18.66 $0.00 Decks/Balconies/Stairs $18.66 $0.00 Retaining Walls, concrete,masonry $22.96 $0.00 Pools/Spas-Gunite $48.80 $0.00 Tl/Stores, Offices 1,597 $43.32 $69,182.04 Tl/Medical, restaurant, H occupancies $60.29 $0.00 Photovoltaic Systems/ # of panels $400.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fire Sprinkler System $3.73 $0.00 Air Conditioning - commercial $6.03 $0.00 Air Conditioning - residential $5.02 $0.00 Fireplace/ concrete, masonry $4,621.70 $0.00 Fireplace/ prefabricated Metal $3,141.89 $0.00 $0.00 $0.00 TOTAL Valuation: $69,182 Comm/Res (C/R): C Building Fee $493.76 Plan Check Fee $345.63 Strong Motion Fee $15.00 Green Bldg. Stand. Fee $1.00 Green Bldg PC Fee $150.00 License Tax/PFF $2,421.37 License Tax/PFF (in CFD) $1,259.11 CFD isthourof Plan CheckFire Expedite Plunnbing TBD Mechanical TBD Electrical TBD $69,182.04 CFD 0 Yes (PFF= 1.82%) 0 No (PFF = 3.5%) Land Use: Density: Improve. Area: Fiscal Year: Annex. Year: Factor: CREDITS PFF and/orCFD Explanation: City ofCarlsbad Permit No: Address Valuation Worksheet Assessor Parcel No. Date Building Division By Type of Work Area of Work Multiplier VALUE SFD and Duplexes $132.05 $0.00 Residential Additions $157.88 $0.00 Remodels / Lofts* $68.98 $0.00 Apartments & Multi-family $117.70 $0.00 Garages/Sunrooms/Solariums $34.45 $0.00 Patio/Porch/Carport $11.48 $0.00 Enclosed Patio* $18.66 $0.00 Decks/Balconies/Stairs $18.66 $0.00 Retaining Walls, concrete,masonry $22.96 $0.00 Pools/Spas-Gunite $48.80 $0.00 Tl/Stores, Offices 1,320 $43.32 $57,182.40 Tl/Medical, restaurant, H occupancies $60.29 $0.00 Photovoltaic Systems/ # of panels $400.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fire Sprinkler System $3.73 $0.00 Air Conditioning - commercial $6.03 $0.00 Air Conditioning - residential $5.02 $0.00 Fireplace/ concrete, masonry $4,621.70 $0.00 Fireplace/ prefabricated Metal $3,141.89 $0.00 $0.00 $0.00 TOTAL $57,182.40 Valuation: $57,182 Comm/Res (C/R): C Building Fee $440.84 Plan Check Fee $308.59 Strong Motion Fee $12.00 Green Bldg. Stand. Fee $1.00 Green Bldg PC Fee $150.00 License Tax/PFF $2,001.38 License Tax/PFF (in CFD) $1,040.72 CFD 1st hour of Plan CheckFire Expedite Plumbing TBD Mechanical TBD Electrical TBD CFD 0 Yes (PFF= 1.82%) 0 No (PFF = 3.5%) Land Use: Density: Improve. Area: Fiscal Year: Annex. Year: Factor: CREDITS PFF and/orCFD Explanation: City ofCarlsbad Permit No: Address Valuation Worksheet Assessor Parcel No. Dale Building Division By Type of Work Area of Work Multiplier VALUE SFD and Duplexes $132.05 $0.00 Residential Additions $157.88 $0.00 Remodels / Lofts* $68.98 $0.00 Apartments & Multi-family $117.70 $0.00 Garages/Sunrooms/Solariums $34.45 $0.00 Patio/Porch/Carport $11.48 $0.00 Enclosed Patio* $18.66 $0.00 Decks/Balconies/Stairs $18.66 $0.00 Retaining Walls, concrete,masonry $22.96 $0.00 Pools/Spas-Gunite $48.80 $0.00 Tl/Stores, Offices 1,804 $43.32 $78,149.28 Tl/Medical, restaurant, H occupancies $60.29 $0.00 Photovoltaic Systems/ # of panels $400.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fire Sprinkler System $3.73 $0.00 Air Conditioning - commercial $6.03 $0.00 Air Conditioning - residential $5.02 $0.00 Fireplace/ concrete, masonry $4,621.70 $0.00 Fireplace/ prefabricated Metal $3,141.89 $0.00 $0.00 $0.00 TOTAL Valuation: $78,149 Comm/Res (C/R): C Building Fee $533.45 Plan Check Fee $373.42 Strong Motion Fee $16.00 Green Bldg. Stand. Fee $1.00 Green Bldg PC Fee $150.00 License Tax/PFF $2,735.22 License Tax/PFF (in CFD) $1,422.32 CFD isthourof Plan CheckFire Expedite Plumbing TBD Mechanical TBD Electrical TBD $78,149.28 CFD 0 Yes (PFF= 1.82%) 0 No (PFF = 3.5%) Land Use: Density: Improve. Area: Fiscal Year: Annex. Year: Factor: CREDITS PFF and/orCFD Explanation: PLUMBING, Development Services ELECTRICAL, Building Division CITY OF MECHANICAL 1635 FaradayAvenue 760-602-2719 CARLSBAD WORKSHEET B-18 www.carlsbadca.eov Building^carlsbadca.gov Project Address: Permit No.: Information provided below refers to worb being done on the above mentioned permit only. This form must be completed ami returned to the Buildinq Division before Ihe permit tun be issued. Building Dept. Fax: (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains New building sewer line? Ves No Number of new roof drains? J0 Install/alter water line? V- 3 Number of new water heaters? Number of new, relocated or replaced gas outlets? Number of new hose bibs? Residential Permits: New/expanded service: Number of new amps: Minor Remodel on/y: Ves No Commercial/industrial: Tenant Improvement: Number of existing amps involveclin this proiect: \, yt Number of new amps involved in this project: ^S^lK^l^^t^ ^ <r-> Moo "r 2. New Construction: Amps per Panel: ^.CA^ Single Phase Number of new amperes Three Phase Number of new amperes ^OIT) Three Phase 480 Number of new amperes Number of new fumaces, A/C, or heat pumps? ^ ^ ^^vv^ ^^ITj^ New or relocated duct worb? Ves No ^^""^^ Number of new fireplaces? J0 Number of new exhaust fans? (^ Relocate/install vent? Number of new exhaust hoods? Ic^ i Number of new boilers or compressors? Number of HP ^fy B-18 Page 1 of 1 Rev. 03/09 PC150014 1925 CALLE BARCELONA CB150860 THE FORUM- DIVIDE EXISTING 160 6000 SF SUITE^FORMFRI Y COI DWATFR CRFFKl INTO . 1925 CALLE BARCELONA CB150863 163 a>(3S'|lC piLet.^ ho CK^ ^ 1925 CALLE BARCELONA Final Inspection required by: a Plan a CM&I SW QlSSUED Approved BUILDING PLANNING ENGINEERING FIRE Expedite? Y (rij DIGrrAL FILES Required? Y N HazMat APCD Health Forms/Fees Sent Encina Fire HazHealthAPCD PE&M School Sewer Stormwater Special Inspection CFD: Y N LandUse; Density; ImpArea; PFF; Y N Comments Date i Building 4/3/'^ Planning / Engineering Fire Need? d&rr^rzuoeir i, tOFo