Loading...
HomeMy WebLinkAbout1930 PALOMAR POINT WAY; 105; CB071244; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 07-12-2607 Commercial/Industrial Permit Permit No: CB071244 Building Inspection Request Line (760) 602-2725 Job Address: 1930 PALOMAR POINT WY CBAD St: 105 Permit Type: TI Sub Type: INDUST Parcel No: 2121205000 . Lot #: 0 Status: ISSUED Valuation: $9,742.00 Construction Type: NEW Applied: 05/04/2007 Occupancy Group: Reference #: Entered By:. LSM Project Title: SONARTEC GOLF- INSTALL 10' Plan Approved: 07/12/2007 HIGH STORAGE RACKS Issued: 07/12/2007 Inspect Area: Plan Check#: Applicant: COLBRESE MATERIAL HANDLING SUITE . 12600 STOWE POWAY CA 92109 858-486-6920 . ,. . . Owner:. LANIKAI.PARTNERS II .. . P p BOX 445 SANTA YNEZ CA 63460 Building Permit $99 69 Meter Size Add 'I Building Permit Fee / $0:00 Add I Red Water Con Fee $0.00 Plan Check $64.80 Meter Fee $0.00 Add 'I Plan Check Fee $0.00 SDCWA Fee $0.00 Plan Check Discount . $0.00 CF.D Payoff Fee . . $0.00 Strong Motion Fee $2 05 P F F (3105540) $0.00 Park Fee $0.00 PFF (4305540) $0.00 LFM Fee $0.00 License Tax (3.104193) $0.00 Bridge Fee . $0.00 License Tax (4304193) . ., . $0.00 BTD #2 Fee $000 Traffic Impact Fee (3105541) $0.00 BTD #3 Fee $0.00 Traffic ImpactFee (4305541) $0.00 Renewal Fee $000 PLUMBING TOTAL $000 Add I Renewal Fee $0 00 ELECTRICAL TOTAL-$0 00 Other Building Fee WOO MECHANICAL TOTAL $0.00 Pot Water Con Fee .$0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $0.00 Add'l Pot. Water Con. Fee . $0.00 Redev Parking Fee .. . $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 HMPFeé ?? TOTAL PERMIT FEES $166.54 Total Fees $166.54 Total Payments To Date $166 54 Balan6e Due $0.00 FINAL APPROVAL Inspector: V' 1L4" Date: ori/ 9/c7 Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of thesd fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute 6f limitations has previously otherwise expired. FOR OFFICE USE ONLY PLAN CHECK NO. PERMITAPPLICAT1ON ' ': EST.VAL.t'74'2oo Plan Ck.Depot (4. I'Q CITY OF CARLSBAD BUILDING DEPARTMENT .. - Validated By 1635 Faraday Ave:, Carlsbad CA 92008 '. Date ' 57 '7'/b ' 1. PROJECT INFORMATION - 'aIor.- Aj. Address (I de Bidgl kite #). ( i .....- Business Name (at this address) &Of1ifl'_-"Ok" 101 'j. Legal 0esa4t1on ' Lot No. SubdivisionName/Number / -, Unit No. ' Phase No It Total # of units Pro Use. CAE i bn Use Description o ork SQ. FT. # of Stones # of Bed ooms #of Bathrooms mame . .1 A00rSs , City ' Statelzlp 14 ITelephone # ' , ' Fax # name ACCress -; - (j 'cay . State/Zip - 'Telehoñe # U a a24 0.1'.. Name (J Address City (J . V S1e/Zip Telephone# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct alter, improve, demolish or repair any structure, prior to Its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by anyapjcant fora pe"g sujeds the,appjiçant to I çivjl penalty çf not more than five hundred dollars ($5001). .. t) Name State License - Address 0 ' /çi.4 City ''State/Zip - Telephone # Ucense Class - ' - City Business License # I ') Designer Name Address City State/Zip ' Telephone# State License #______________ 6WRKER'S"C'øMPENSATIaN ' Workers' Compensation Declaration: 1 hereby affirm under penalty of perjury one of the following declarations: a I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. I have and will maintain worker's compensation, as required by Section 3700'of the labor Code, for the perfo'rmance of the work for which this permit Is Issued. My worker's compensatloninsMiance carrier and policy number are: InsuranceCompany ')(.4 f ' PolicyNo.002' g4-0(7 4' ExpirationDate — I' 2°1 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1003 OR LESS) a CERTIFICATE OF EXEMPTION: I certify that In the performance p of the work for which this miit is Issued, I shall not employ any person In any manner so as to beâome subject to th orkers' Compensation L'aws of California WARNING: Failure d shall subject an employer to criminal penalties and civil fines up to one hundred thousand q /- SIGNATURE DATE dollars($1 00,000), I ad iti Code, interest and aftomev'/o1 sjees I hereby affirm that I am exempt from the Contractor's License Law for the following reason: a r I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure' is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or through his own employees, 'provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale). - a i, as owner of the proerty, am exclusively contraing with licensed contractors to construct the project (S. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). ' . . '• - ' ' a lam exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and inaterials for construction of the proposed property improvement. 13-YES 0 NO - I (have/have not) signed an application fora building permit for the proposed work. ,' I have contracted with the following person (firm) to, provide the proposed construction (include name / address! phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supeivise and provide the major work (include name I address / phone number/ /ontractors license number): - - I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (Include name / address / phone number type of work): 'PROPERTY OWNER SIGNATURE - DATE WHITE: File YELLOW: Applicant PINK: Finance - p PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1,635 Farádày Ave.', Carlsbad CA 92008 Page 2of2 . [COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUU..OING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous mater1pls•registration for or risk management and prevention program under SectIons 25505,25533 or, 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES NO Is the applicant or future building occiint requited to obtain a permit from the air pollution control dislrit oralr quality management district? D YES .JiO Is the facility to be cnstrued within 1,000 feet of the outer boundary'of a school site? 0 YES @LNO . IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF, OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF ThE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a con?truction lending agency for the performance of the work for which this permit is issued (Sec. 3097(l) Civil Code). . LENDERSNAME LENDER'S ADDRESS =APPLICANT CERTIFICATION - I certity, that I have read the application and state that the above information ls.correctand that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction [.hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for Inspection purpose I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS ThE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGEMENTS COSTS AND I EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations of 5 &.d6 ep and demolition or construction of structures over 3 stones in height. EXPIRATION: Eveiy permit Issued b e building Official under the provisions of this Code shall expire by limitation and become null and void If the building or work authorized 'by such permit is not commenced in 80 days or the datef such permit or if the building or work authorized by such permit is suspended abandoned at anytime after the work Is commenced for a period 11 days ( ecti n 106.4.4 fif0m.Building Code). .•. - APPLICANTS SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance S City of Carlsbad Bldg Inspection Request For: 07/18/2007 - Permit# CB071244 Inspector Assignment: Title: SONARTEC GOLF- INSTALL 10 Description: HIGH STORAGE RACKS Type: TI Sub Type: IN DUST Phone: 8584866920 Job Address: 1930 PALOMAR POINT WY Suite: 105 Lot 0 Location: Inspector: ;me, _ APPLICANT COLBRESE MATERIAL HANDLING Owner: LANIKAI PARTNERS II Remarks: Total Time: • Requested By: ANITA Entered By: CHRISTINE CD Description Act • Comment • • 19 Final Structural • - Comments/Notices/Holds Associated PCRs/CVs Original PC# • CV070350 OPEN • H- NO PERMIT FOR STORAGE RACKS; • •• Inspection History Date Description Act !nsp Comments EsGil Corporation In Partnership with government for Bui(ding Safety DATE: 5/22/07 O APPLICANT URIS. JURISDICTION: City of Carlsbad 0 FILE REVIEWER PLAN CHECK NO.: 071244 SET:!! PROJECT ADDRESS: 1930 Palomar Point Way #105 PROJECT NAME: Storage Racks for Sonartec Golf LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substáptially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant dèficiecies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant- contact person. LI The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax Mail Telephone Fax In Person REMARKS: .1. .1. Fire Department approval is required 2 Citlto field verify that the path of travel from the handicapped parking space to the rack area and the bathrooms serving the rack area comply with all the current disabled access requirements. By: David Yao Enclosures: Esgil Corporation LI GA []MB []EJ L] PC log 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858)560-1468,* Fax(858)560-.1757r6 9 - - EsGul Corporation In (Partners flip with çovernmentforBui&uing Safety DATE: 5/16/07 O APPLICANT JURISDICTION: City of Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 071244 SET:! PROJECT ADDRESS: 1930 Palomar Point Way #105 PROJECT NAME: Storage Raëks for Sonartec Golf LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by-building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the checklist is enclosed for the jurisdiction to forward to the applicant contact person. F71 I The applicant's copy of the check list has been. sent to: Anita Thornton 12600 Stowe Dr. #3 Poway, CA LII Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff .didadvise the applicant that the plan check has been completed. Person contacted: Anita Thornton Telephone #: 858-486-6920 Date contacted 77/O1 (by) Fax #: Mail Telephone yrFax k(/In Person LI REMARKS: By: David Yao Enôlosures: Esgil Corporation El GA [1 MB [1 EJ El PC 5/7 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 City of Carlsbad 071244 GENERAL PLAN CORRECTION LIST IJURISDICtION City of Carlsbad PLAN CHECK NO.: 071244 PROJECT ADDRESS: '1930 Palomar Point Way #105 DATE PLAN RECEIVED BY DATE REVIEW COMPLETED: ESGIL CORPORATION: 5/7 . 5/16/07 11 REVIEWED BY: David Yao FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code, and state laws regulating energy conservation, noise attenuation and disabled' access. This plan review is based on regulations, enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or Other departments. . The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. ,Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. . . . Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with, the revised plans. . Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? El Yes UNo City of Carlsbad 071244. S/ O7 1. Only the storage racks are included in this plan review 2 Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24. ' 3. UBC Section 107.2 requires the Building Official to determine the total value of all construction work proposed under this permit. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed 4. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E.- 5. Obtain Fire Department approval for groups F, M and S occupancy storage per UBC Sections 306.8, 309.8 and 311.8. 6. City to field verify that the path of travel from the handicapped parking space to the rack area and the bathrooms serving the rack area comply with all the current disabled access requirements. Recheck the "pallet" racks as follows: 7. Recheck all connections on sheet 1 as follows: The rivet bearing capacity is only dtF = 0.406(0.0747)65 = 2 kips. Provide calculations for all beam, to bracket weld capacities, per Section 2330 (allowable weld stress is the member thickness times 26 ksi times 1.33, or the weld stress, whichever is lower). Check the bracket maximum weak axis moment. 8. Provide calculations for the column weak axis bending plus axial for transverse seismic loading. The axial load is the maximum compression load at the basefrom vertical.plus ,seismic overturning. The column moment will probably be maximum for the lateral load from the base plate to the first diagonal brace (not only to the first horizontal member). 9 . The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. City of Carlsbad 071244 VALUATION AND PLAN CHECK FEE' JURISDICTION: City of Carlsbad PLAN CHECK NO.: 071244 PREPARED BY: David Yao 'DATE: 5116/07 BUILDING ADDRESS: 1930 Palomar Point Way #105 BUILDING OCCUPANCY: ' TYPE OF, CONSTRUCTION: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. ' Mod.' VALUE ($) racks ' 6500 1.11 7,215 Air Conditioning Fire Sprinklers TOTAL VALUE 7,215 Jurisdiction Code Icb ' IBY Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: El Complete Review fl Structural'Only El Other El Repetitive Fee [1 Repeats o Hourly • ' ' Hour * Esgil Plan Review Fee Comments: $84.29 I $54.791 $47.201 Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS• PERMIT NUMBER CB 7 DATE 7/Y7c y ADDRESS RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (< $10,000.00) S. CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER -ENGINEER DATE DATE - oocslMlsrcrmsiplannlng Engineering ApprOvai5 PLANNING DEPARTMENT , BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB 07-1244Address:' 1930 Palomar Point Way #105 ¶ Planner: Jo Marquez Phone: (760)602-4619 APN: 212-120-33-00 Type of Project & Use: TI Net Project Density: DU/AC Zoning:P-M General Plan: PI - Facilities Management Zone: 5 CFD (in/out) # Date of participation: Remaining net dev acres: -. ç7, Circle One 1 • (For non-residential development: Type of land used created bythis permit:___________________________________________________ Legend: Z Item Complete Qltem Incomplete - Needs your action LI LI Environmental Review Required: YES NO X TYPE DATE OF COMPLETION: Compliance with Conditions of approval? If not, state conditions which require action. Conditions of Approval: LI LI Discretionary Action Required: YES NO X TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:________________________________________________________ LI LI Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_____ NO X CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): LI LI Habitat Management Plan Data Entry Completed? YES NO _X If property has Habitat Type, identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus , (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type , irrpaôfed/taken, UPDATE!)-' . LI LI Inclusionary Housing Fee required: YES NO X (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan: LI LI Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easement existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes).'- Provide legal description of property and assessor's parcel number. - Policy 44 - Neighborhood Architectural Design Guidelines LI LI 1. Applicability: YES NO LI LI 2. Project complies YES NO ' Zoning: LI LI 1.' 'Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required ' Shown - Rear: Required ' Shown Top of slope: Required Shown LI LI 2. Accessory structure setbacks: Front: ' Required Shown 'Interior Side: Required Shown - Street Side: Required Shown Rear: Required ' Shown Structure separation: ' Required Shown LI LI Lot Coverage: Required Shown LI LI 'Height: ' ' Required Shown LI LI Parking: Spaces Required ' Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown (zX]LI Additional Comments: Correction #1- Please show the required parking spaces for this site, see attached for further information, thank you! OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER OATl 7 H:'ADMIN\cOUNTER\BldgPlnchkRevChklst Rev 3/06 MEM Carlsbad Fire Department Plan Review Requirements Category: TI, INDUST Date of Report: 07-11-2007 Name: Coibrese Material Handling Address: BUILDING DEPT copy 44t CARLSBAD FIRE DEPARTMENT Permit #: CB07 1244 Job Name: SONARTEC GOLF- INSTALL 10' Job Address: 1930 PALOMAR POINT WY CBAD St: 105 . 11FWLFftThe item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached: Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval-. Conditions: Cond:CON0002107 [MET] Comply with Articles 1 and 81 of the California Fire Code for high-piled combustible storage Please complete attached 'Statement of Intended Use'. Provide additional information on the existing or proposed smoke removal system, type, location, and specifications of smoke removal system. provide additional information on commodity(ies) to be stored in accordance with Article 81 of the CA Fire Code. (combustibles, non-combustibles, plastics etc.) Provide information on maximum pile volume for each storage array. High piled combustible storage is storage of combustible materials of more than 500 square feet where materials are stored over 12 feet in height from the floor to the top of the storage. For certain high-hazard commodities, storage height over '6 feet will require a permit from the fire department. Entry: 05/18/2007 By: GR Action: CO Entry: 07/11/2007 By: gr Action: AP Cond: BP023 [MET] Refer to Article 1 of the California Fire Code for permits required for this process. Entry: 07/11/2007 By: gr Action: AP Action Comments L - By'I Date - CO GR 05/18/2007 AP GR 06/12/2007, Carlsbad Fire Department Plan Review Requirements Category: TI, INDUST Date of Report: 05-18-2007 BUILDING DEPT. COPY Reviewed by: Name: Coibrese Material Handling Address: Permit #: CB07 1244 Job Name: SONARTEC GOLF- INSTALL 10' Job Address: 1930 PALOMAR POINT WY CBAD St: 105 INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0002 107 [MET] Comply with Articles 1 and 81 of the California Fire Code for high-piled combustible storage. Please complete attached 'Statement of Intended Use'. Provide additional information on the existing or proposed smoke removal system, type, location, and specifications of smoke removal system. provide additional information on commodity(ies) to be stored in accordance with Article 81 of the CA Fire Code. (combustibles, non-combustibles, plastics etc.) Provide information on maximum pile volume for each storage array. High piled combustible storage is storage of combustible materials of more than 500 square feet where materials are stored over 12 feet in height from the floor to the top of the storage. For certain high-hazard commodities, storage height over 6 feet will require a permit from the fire department. Entry: 05/18/2007 By: GR Action: tO Cond: BP023 [NOT MET] Refer to Article 1 of the California Fire Code for permits required for this process. MAY-1 -2U01 FRI 04:57 PM CMH INC. FAX No. 858 486 6925 P. 005 BY........ P....NJAN : RACK DESIGN & ENGINEERING CO. . 412 WEST BROADWAY #204 SHEET NO......................... GLENDALE, CA; 01,204 JOB NO... ..... SUBJECT TEtft81a)240-aaió J'x.(ei6)U0-3e13 5 a 4,tA re c 40Lp - 7,91 PLA IV ,ø8h 04 1O* ol y 33 > It .. f r .r2. l.iA.,#.0 PI4 Z8 jk. 1-7 0'7 /R V IS3Q >1 ct8E-D-ete E0:6Z Le/1tIqc4 BY; RAdK DEIdN & EN(INEERIN( do. DATE 412 WEST BROADWAY, ØrrE #204 SHEET NO.......................... dLENDALE,. dA. 91204 JOB NO...J?T SUBJECT TEL:(818)240-3810 FAX:(818)240-3813 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: . . S SONARTEC GOLF . . . 1930 PALOMAR POINT WAY . . . CARLSBADE, CA. 92008 . PER CBC 2001 EDITION STORAGE RACKS CAPACITY: 1 000 # / LEVEL AT 2 & 3 BEAM. LEVEL RACKS 500 # / LEVEL AT 4 BEAM, LEVEL RACKS CALCS. 1 THRU 5 DRAWINGS: RD-1 2063 /7 OH4 in Lu No. cO53524 EXP.: 6/30/07 S 4). Ze) SIDE VIEW RACK DEIN & ENaINEERINQ Co. 2 DATE 7 412 WEST BROADWAY. SUITE #204 SHEET NO......................... GLENDAlE, CIA. 91204 JOB NO.. SUBJECT 'rEL:(818)240-3810 FAX:(818)240-3813 96" 500 #1 LEVEL '4F H TYPE "C" I CI6" T U 96" TYPE "A'1 TYPE "B'. 96" 1 1000 #1 LEVi 96' If 0 ur TYPE "0" TYPE 'E" . TYPE "F" SIDE VIEW 1' 1000 / LEVEL TYPE "0', r 48 ----i 1AC_ LONG EAM 'x S=1.2 Fy =50 K5 1. cq =4<1.2 12 3/4" . = 5xWxL_ 3" <144_ 8" 384xI, xE 180 -. ... SIDE VIEW 1000 #/ LEVEL+25% IMPACT C3x3.5 BEAM LOAD 600 #1 BEAM I=1.44 [[ I=139 S=73 - Sx=.92 rn Fy 50K5L Fy=5oKst. 1.2 3/4j 95'• BEAM M 6"x6K =7.2"K s.7*K= .24<73 = 5xWxL.... 384xlx xE so 1 "K 8 ". 0 .6 "' 6 K BY .RAdK DEIdN .& . .EN(INEERIN( do.. DATE ......4T. 412 WEØT BROADWAY, ØUITE #204 SHEET NO. 6rEN1iii, .dA. 91204 JOB NO....?T SUBJECT . TEL:(818)20-3810 FAX:(818)240-3813 SEISMIC DESIGN . . 2.5xCaxI x W CBC 2001 SEC. 2222 WORKING 1=1 STRESS R=5.6 MOM. CONN: • S • S • . R=4.4 BRACED Ca=.44 . S W=D.L.+L.L. . . . S • S • S • LONGIT. SEISMIC. . . • . S • S LOAD PER COLUMN S S . . • 2 BEAM LEVELS: . . . . - r 2 K F 2x1K_IK . S co . S ,2 COL. . . . S. . _.07' 2"xi 6,'K W=.lDLI 1L.L. 1.1 K . S . • • • : v 2.5x.44x1.1 =.'1.5 K . •. . . LONGIT. 5.6x1.4 . . . . . V =2.5x.44x1.1 = K TRANS. 4.4x1.4 . . •55 -:;--5.K 0 . . 3 BEAM LEVELS - 3x1K —15K 2 COL. W=.lDl 15L.L 1.6K V ._2.5x.44x1.6 =.22K LONGIT. 5.6x1.4 V = 2.5x.44x1.6 =.28 K TRANS. 4.4x1.4 4 BEAM LEVELS p= 4X.5K._1 2COL. D1t 1L.CT 1•1K V = 2.5x.44x1.1.... .15x LONGIT. 5.6x1 .4 BY ......... ...OHAN1AN. RAciK DEIdN & ENdINEERINc4 do. DATE . ..... 4-2--O7 412 WET BROADWAY, U1TE #204 SHEET NO ........... .4 12063 (LENDALE, CIA. 91204 JOB NO. ...?T SUBJECT TEL:(818)240-3810' FAX:(818)240-3813 COLUMN ANALYSIS 1 5/8W 'I Fy"50 KSI JJ_40x1.7_.62 Fe=''1!2 =64 T- A=.43 x 1.1 (K ) 2 ry 1 42 Sx:.36 ry .63 Fn — !L)4OKsI r y =. M0xSx.Fb=11 K P'=FxA= 17K Pa 192 COMBINED STRESS RATIO -+J-= 11i -ii- = .90<1.33 1.6K BASE PLATE ANCH: TENSION = 0 ANCHOR SHEAR = .22 K BASE PLATE (1)-1/2"0 HILTI KWIK BOLT-3 ANCHOR ESR-1385 OR APPROVED EQUAL. DESIGNED FOR 1/2 STRESS. (No SPECIAL INSPECTION REQ'D) ALLOW. TENSION=.9 K ALLOW: SHEAR=1.5K p 5/3 v 5/3 5/3 22 5/3 (-) +(-) =(--) +(—) = .04<1.33 a a 1.5 RACK COLUMNS' DESIGNED SUCH THAT IF THE FRONT COL. IS DAMAGED THE REAR COL. HAS EXTRA CAPACITY TO SUPPORT THE FULL LOAD OF THAT BAY, (SEC. 2222-5) MOMENT AT BEAM CONNECTION 7/1 6"ø RIVET •, . A.1 Fy79 KSI Va .1x79x.4 3K 5K Ma 3Kx4"x1.33=16 2 OR 3 PIN CONN. CONN. ' 2"K I. 5 K L 10 0 8 K BOTH SIDES TYP Fi t=.O7' BY .c.:...PftN!AN. RAdKDEliN &. ENINEERIN do. 'DAit 412 WET BROADWAY, UITE #204 SHE NO. . S (LEDALE, dA. .91204 JOB NO. SUBJECT TEL'.-(818)240-3810 FAX (818)240-3813 OVERTURNING TOP LEVEL LOADING MOT= .28Kx2x88x.5x.1.15 28 "K M01=.O9Kx2x88" 16 "K MR = 1.6Kx42 =67K MR=.65Kx42"=27 I. "K5 NO UPLIFT LOAD TO DIAGONAL P = .28Kx2x.2 =.691( 42 F=50 KSI A=.31 F0= 123KS1 r=.48 P = Q.=.74 a L= 56" CHECK WELDS 1/8" WELD 1.5" LONG EACH ,SIDE (3" TOTAL) 3x.125x.707x70x.3 = CHECK SLAB 1600 1.6x144=230D" M(*f)2x1000x .fxl2=510"# 512x52 50 510 50 =10<1.6V=80 1600# 1 5" CONCRETE SLAB 2500 PSI. CONC. irii / 1•000 PSF. SOIL 'F' •4, 4" , 3.5" . . 15" -