HomeMy WebLinkAbout1931 MARCASITE PL; ; CB073064; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-26-2008 Residential Permit Permit No: CB073064
Job Address:
Permit Type:
Parcel No:
Valuation:
Building Inspection Request Line (760) 602-2725
1931 MARCASITE PL CBAD
RESDNTL Sub Type:
Lot#: 2132922700
$300,348.00 Construction Type:
SFD
59
VN
Status:
Applied:
Entered By:
ISSUED
12/12/2007
JMA
Occupancy Group:
06/26/2008
Reference#: CT 04-09 Plan Approved:
# Dwelling Units: Structure Type: SFD _Issued: 06/26/2008
Bedrooms: 4 Bathrooms: 4 Inspect Area:
Project Title: TRIESTE PL 3: PHS 6-2742SF LV Orig PC#:
598SF GAR/162SF DECK/162SF LOG/70SF PORCH Plan Check#:
PC 06-35
PC07-76
Applicant:
WARMINGTON HOMES
701 PALOMAR AIRPORT RD
CARLSBAD CA 92011
931-4766
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$1,271.61
$0.00
$826.55
$0.00
($66.12)
$30.03
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$7,702.00
D1
$0.00
$0.00
Owner:
WARMINGTON TRIESTE ASSOCIATES LP
C/O WARMINGTON HOMES CALIFORNIA
3090 PULLMAN ST #A
COSTA MESA CA 92626
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $27,391.53 Total Payments To Date: $27,391.53 Balance Due:
FINAL APPROVAL
$0.00
$225.00
$7,188.00
$3,618.63
$5,466.33
$0.00
$0.00
$0.00
$750.00
$0.00
$0.00
$252.00
$60.00
$67.50
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$27,391.53
$0.00
Inspector: M ~ Date: o'-Clearance: 4-:p...O'\
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations. or other exactions hereafter collectively
referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. lf you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other require<.: information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water .=-!nd sewer connection fees and capactty
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
City of Carlsbad Bldg Inspection Request
For: 06/19/2009
Permit# CB073064 Inspector Assignment: MC ---
Title: TRIESTE PL 3: PHS 6-2742SF LV
Description: 598SF GAR/162SF DECK/162SF LOG/70SF PORCH
Type: RESDNTL Sub Type: SFD
Phone: 7608818240
Job Address: 1931 MARCASITE PL
Suite: Lot: 59
Inspector: fyll. Location: -~---
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks:
Total Time:
CD Description
19
29
39
Final Structural
Final Plumbing
Final Electrical
49 Final Mechanical
Requested By: KYLE ISBELL
Entered By: CHRISTINE
Act · Comments
_tL ---=O-'=IL,=-~---'--"'--'¢.L=;"'-"". (=,~e::46=E-;""--'~=A:.::~:.__icM$-=r(JuE.e(l,=----
yL.u~ H. It jqU,-'"" ~--r"~ ~It..
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lns~ection Histo!Y
Date Description Act lnsp Comments
06/15/2009 89 Final Combo co MC CK KITCHEN, ELECTRICAL SHORT
05/07/2009 39 Final Electrical AP MC EMR ONLY, OK TO RELEASE
03/26/2009 23 Gas/Test/Repairs AP MC
03/25/2009 17 Interior Lath/Drywall PA MC DRYWALL ONLY, DBL, CK UNDER STAIR
03/25/2009 18 Exterior Lath/Drywall AP MC
03/25/2009 23 Gas/Test/Repairs NR MC RE-TEST
03/24/2009 82 Drywall/Ext Lath/Gas Test NR MC NO SUPER ON SITE
03/23/2009 17 Interior Lath/Drywall co MC SCRAP OUT
03/23/2009 18 Exterior Lath/Drywall co MC
03/23/2009 23 Gas/Test/Repairs co MC PROVIDE TEST
03/16/2009 16 Insulation NR MC COMPLETE PICK UP
03/16/2009 16 Insulation AP MC SECOND STOP, PICK UP COMPLETE
03/13/2009 16 Insulation PA MC COMPLETE PICK UP
City of Carlsbad Bldg Inspection Request
For: 05/07/2009
Permit# CB073064 Inspector Assignment: MC ---
Title: TRIESTE PL 3: PHS 6-2742SF LV
Description: 598SF GAR/162SF DECK/162SF LOG/70SF PORCH
Type: RESDNTL Sub Type: SFD
Phone: 7608818240
Job Address: 1931 MARCASITE PL
Suite:
Location:
Lot: 59
Inspector: _ __,M'--_t,,._
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks:
Total Time:
CD Description
39 Final Electrical
Act Comments
Requested By: KYLE
Entered By: JANEAN
k ~ t>N)µ() CIC,, ,:o \Z..~'-G.Mt:.
H,e.-r1=,~ --------
Comments/Notices/Holds
Associated PC Rs/CVs Original PC# PC 06-35
lns12ection Histoiy
Date Description Act lnsp Comments
03/26/2009 23 GasfTest/Repairs AP MC
03/25/2009 17 Interior Lath/Drywall PA MC DRYWALL ONLY, DBL. CK UNDER STAIR
03/25/2009 18 Exterior Lath/Drywall AP MC
03/25/2009 23 Gas/Test/Repairs NR MC RE-TEST
03/24/2009 82 Drywall/Ext Lath/Gas Test NR MC NO SUPER ON SITE
03/23/2009 17 Interior Lath/Drywall co MC SCRAP OUT
03/23/2009 18 Exterior Lath/Drywall co MC
03/23/2009 23 GasfTest/Repairs co MC PROVIDE TEST
03/16/2009 16 Insulation NR MC COMPLETE PICK UP
03/16/2009 16 Insulation AP MC SECOND STOP, PICK UP COMPLETE
03/13/2009 16 Insulation PA MC COMPLETE PICK UP
03/12/2009 16 Insulation NR MC PER CONTRACTOR AFTER STOP
03/10/2009 16 Insulation NR MC COMPLETE INSTALLATION
03/05/2009 84 Rough Combo AP MC MINOR PICK UP
03/03/2009 84 Rough Combo co MC COMPLETE ALL TRADES
02/18/2009 13 Shear Panels/HD's AP MC
02/17/2009 13 Shear Panels/HD's NR MC COMPLETE NAIL PLATING
02/12/2009 13 Shear Panels/HD's co MC
01/14/2009 15 Roof/Reroof AP MC
-.,_)
1
<
I I
I I
I I I
I
I
m CltJ DI Clrllbld
-,Flnal Bulldlna IDSPICIIOD
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check#:
Permit#:
Project Name:
Address:
Contact Person:
Sewer Dist:
PC0?-76
CB073064
TRIESTE PL 3: PHS 6-2742SF LV
598SF GAR/162SF DECK/162SF LOG/70SF PORCH
1931 MARCASITE PL
Phone:
LC Water Dist: CA
Date:
Permit Type:
Sub Type:
Lot: 59
05/14/2009
RESDNTL
SFD
J h 2 0
..........................................................................................................................................................
Inspected
l:Mkc2'>
Date ~/rs(Q°r By: C Inspected: Approved: Disapproved:~
Inspected Date
Approved: --6'sapproved: __ By: Inspected: s('Ml{rA
Inspected Date
By: Inspected: Approved: Disapproved: __
Comments: _____________________________ _
;,1; '.;OIL & 1 tS TING. INC
Ir. ~
..;
•I. (.) z (! w ;:
Southern California Soil and Testing, Inc.
6280 Riverdale Street, San Diego, CA 92120 (619) 280-4321
P.O. Box 600627, San Diego, CA 92160-0627
::,
0 <I) 83-740 Citrus Avenue, Suite G, Indio, CA 92201 -3438 (760)775-5983
Concrete (4x8) Compressive Strength Test Report
File Number: 0612215
Project Title: Trieste at La Costa Greens PTCC Phase: 6
Project Location: 1931 Marcasite Place
Architect: William Hezmalhalch
Engineer: Davidson Reinforcing
Contractor: Warmington
Location In Structure: Lot: 59 Right Rear Slab on Grade
Material Supplier: Superior
Mix Designation: 375p
Admixture(s): n/a
Time In Mixer:
Air Content: (ASTM C173/C231)
Air Temp:
Truck Number:
Samples Made By: (ASTM C31)
Laboratory Number
Mark On Samples
Date Made
Date Received
Date Tested
Diameter, Inches
Area, Square Inches
Maximum Load, Pounds
Compressive Strength, psi
Age Tested
Required 28 Day Strength, psi
Fracture Type
50 minutes
68 degrees F
025
JB
0879682
LOT59
11/7/2008
11/8/2008
11/17/2008
4.00
12.57
58,600
4660
10 Days
4500
Permit No:
Plan File No:
CB73064
Carlsbad
Slump inches: (ASTM Cl 43)
Unit Weight Plastic/Dry, pcf: (ASTM
C138/C567)
Concrete Temp: (ASTM C1064)
Ticket Number:
Samples Tested By:
0879683 0879684
11/7/2008 11/7/2008
11/8/2008 11/8/2008
12/5/2008 12/5/2008
4.00 4.00
12.57 12.57
73,770 72,160
5870 5740
28 Days 28 Days
4500 4500
1 1
4.25
I
72 degrees F
133153
CN DH
Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM C39
standards. This agency makes no other warranties express or implied.
Fracture Type: 1 -Reasonably well formed cones on both ends, less than 1 in. of cracking through caps; 2 -Well formed cone on one end, vertical
cracks running through caps.no well defined cone on other end; 3 -Columnar vertical cracking through both ends, no well formed cones: 4 -Diagonal
fracture with no cracking through ends: 5 -Side fracture at top or bottom (occur commonly with unbonded caps); 6 -Similar to type 5 but end of
cylinder is pointed.
Distribution:
(1) City of Carlsbad -Building Inspection Department
(1) Warmington Homes California
Reviewed By: ~ ~-z---r
Gordon T.M. Woodard RCE # 60481
., . •
l'll\NNINC;
HUNSAKER
&ASSOCIATES
S /\ N I• I I ti II, I r,,I \,
ENGiNEE"Nc October 31, 2008
~llllVtY1N1;
IININt
,m ,,N~FI F$ City of Carlsbad
. "v' ""'"· 1635 Faraday Avenue
,,ANllll(.(.lc rl b d CA 92008-7314 /\k(/.UNA a $ a '
I.EX WllLIMAN
/\ll~I\ VlALl'ANUlJ
!JAN SMITH
1./\YMAtHIN
0-ll JC!< C 1\11 I~
'.1707 w~~/,., .:.1r1.:c1
;.;,111 ll1q:11, Cl\ '!,!I ;•1
(1'1'il1J 55t!-450tl l'H
Ul1il\l !i~/1-1•1 HI)(
www.Hun~,1kcrSO .1·, ""
lnl 1,~0l·lo , 11~.ilt!rSI l .,:1111 ,
LOO/LOOli!)
Attention-
Regarding
Reference:
District Grading Inspector
Civil Engineer's
Certification of Final Grading
Project
Drawing No:
Lots
La Costa Greens Neighborho :id 1.17
429-2C
50 through 63
Pursuant to Section 11.06.170 of the Carlsbad Municipal C :ode, I hereby state in
my professional opinion all work incorporated in the gradin11 and drainage plans.
authorized under the grading permit to include grading, dra 11age and
construction of appurtenant structures, has been constructud to the lines and
grades in substantial conformance with the approved plans and any approved
revisions thereto.
I further state that the embankment and cut slopes as sho-., 11 on the approved
grading plans have been placed at their proper line and grade.
Respectfully submitted,
as Jossv pue ,aiesunH
DIS~~ k 1U1U'/\]0~1!11}~0 \/ur.•
..,(P o,o~JQM I0/:tl/20094'2UA"1
~L~LB,,8,81 XV1 ,~ LZ BOOZ/0£/01
..
GEOCON
INC OR PO RATE0D•
a.,,_ • ! . ,·
'
FOUNDATION LOCATION ('f t f b ·1d· l 1 no en ire UI lnQ ~
PLAN FILE NO. PERMIT NOS :
l, I ~'I
PROJECT NO. Ot;/~3 -GZ.. 2&.,
DATE : Jl/;/o ~
Pu ... '~ ;It-C.. (3 C T:iC; ~
5!, ( 6"11 '30 ~<& 0 ADDITIONAL OBSERVATION REQUIRED
FOUNDATION TYPE : 5<, cu 0~ 3Q~1 I
0 CONVENTIONAL n c~ a :so 'Pl( SUBSTANTIAL CONFORMANCE 'jlJ' POST-TENSIONED , I si ,V ,3t! 3(J?'t
t:<; ,..,., a-:1. ~l\ f .
• _ PUj.POSE OF OBSERVATION
'll('verify soil conditions exposed are similar to those anticipated
llf(verify footing excavations extend to minimum depth recommended in soil report
D Verify foundation reinforcement complies with minimum recommended in soil report
D Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report
~ Verify footings have been extended to an appropriate bearing strata
0 Other
• SOIL REPORT RECOMMENDATIONS BASED ON :
!( Expansion Condition O VERY LOW O LOW )I MEDIUM O HIGH O VERY HIGH
~Fill Geometry -~~-------------------------------
IX} Other : _ LJ s sy -SlP C.,ff ::n:. 1 LrJs s1-s 'l L A(J( ...
• MINIMUM FOUNDATION RECOMMENDATIONS: ~ Footing Depth : 0 12 Inches ~ 1f i ,..-~s [)t' 241~1JC OTHER __________ _
Footing Reinforcement: 0 No.4 T&B O 2-No.4 T&B O 2-No.5 T&B O Post-Tensioned OTHER : _____ _
Interior Slab Reinforcement : D 6x6-10/10 D 6x6-6/6 D No.3@241nches D No.3@181nches D Post-Tensioned
Slab Bedding Material and Thickness : -------~----Vapor Barrier :
Foundation Width : -;-+-<--~~::--::;-: -tJ.H~-.i~'._!;~1:~~(---1cii c(r.----------
• OBSERVATIONS :
~J ubstantial conformance with Soil Reports (see "Purpose of Observation") ~ Substantial conformance with Foundation Plans. Identify : -4-rr_._~P~IJo'l,0z..n.$+--'1""'1...,_, _ _.Tho:::..:...,..J_,.Ju.,s~o~('.)4-,,,1-< _1....,0/L-1_,P/._q'-'("'ff'----
. Jo~+ :i,.o<o::, I
□ Other
• COMMENTS : -.,,.~------------------------------
IS ASSUMfD THAT All FOOTING EXCAVATIONS Will BE QEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT TH: SOIL MOISTURE CONTENT Will BE MAINTAINED
AELD CO IES TO