Loading...
HomeMy WebLinkAbout1935 CALLE BARCELONA; 170; CB031352; PermitU 08-20-2003 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: RUSSELL STOUT City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Building Inspection Request Line (760) 602-2725 Commercial/lndustriaI Permit Permit No: CB03 1352 4635 CASS ST. 921 09 858-272-8873 1935 CALLE BARCELONA CBAD St: 170 TI Sub Type: COMM Lot #: 0 Status: ISSUED $126,540.00 Construction Type: NEW Applied: 05/07/2003 PANERA BREAD 4218 SF TI Plan Approved: 08/20/2003 Issued: 08/20/2003 Reference #: Entered By: SB Inspect Area: Plan Check#: Owner: ~ ~~ ~ Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Recl. Water Con. Fee $629.72 $0.00 $409.32 $0.00 $0.00 $26.57 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'l Recl. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF PFF (CFD Fund) License Tax License Tax (CFD Fund) Traffic Impact Fee Traffic Impact (CFD Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $2,303.03 $0.00 $0.00 $0.00 $0.00 $0.00 $251 .OO $160.00 $81 .OO $0.00 $0.00 $0.00 $0.00 $3,860.64 Total Fees: $3,860.64 Total Payments To Date: $469.32 Balance Due: $3,391.32 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 3 PLAN CHECK NO. EST.VAL. (ZG,, sqa Plan Ck. Deposit Validated By .j4 Date s;' /7/03 - 469.3z 5. coH~-cowP~~~ Sec 7031 5 Business end pmfesskns Code: Any CMy OT County t toconstrud alter. impwe, demdish or repair )L aka requires the applicant fa such permit to fils a signed statemant tha( he is kend plrsuant to the pwisions 0ftheCuhdofs License Lilw [chapterg, cammdng .wiih Section 7000 of Mvisbn 3 of the Business and pm(esskns Code] OT hat he k exempt Ihecefran. and Ihe bask for thealleged exemptbn Any vidatlon ofsedlon 7031 5 by PROPERTY OWNER SGNAWRE DATE WHITE Fib YEUOW: Micant PINK: Finance I- PERMIT APPLICATION CIW OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of.2 -- cmmLElE*mm- Is he appliirtIor Mure tuildhgoccupmt reqW b submit a Eectiom25505,25533 or25534 afthe Prasley-Tanner Ctazerdare Substance Account Ad? 0 YES ts the appc~anl orb& brilding ocapant required to- a permit the ak pautbn mntrd dis for or risk management and prevention pqmn under or air qdtty management district? YES 6 b~fadliitobeconstrudedwiulin 1.OM)featofhouterbarndaryofaBchoolsite? 0 YES &E IF ANY OF THE ANSWERSARE YES. AFINAL CERTIFICATE OF OCCUPANCY MAY NOT BE lssum UMESS THEAPPUCAKF HAS M€r OR IS YEEnNG THE REQUIREMENTS OF THE OFFICE OF EMERGE a @33wmmmLfllwbl6mcy I hereby aflirm that vlere isacacstruction lending agencyfor EAIR nee of the wak for Wch thls NEWS NAME LENDER'S AWRESS ordinances and slate lam relating to kdkling castrucb 'on Iherebysuthorhe~dtheatydCarkbadbentexupanthesbavementionedprapertyfakispeclia, purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST AU UABIUTRS. JUDGEMENTS. COSTS AM) EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAlD CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. (WHA: An OSHA permHIs requiredforexcavatbns of5O'deep and demdibionorcom~ ofsbudwesowf 3slocies In hdght UBIRATIOK Evacypermitissued by the kil&lg ORida) under the prwisions dlhis codeshail @m bylimitath and beaxne null and void #the building orwurk aulhaired by- permit k not commenced within 1Bodays fran the dale of such pamitor if the buildingorwakaulhomed by such permit is suspended or- at any time after thework ts ammencedlora APPLICANTS SIGNATURE DATE S-/L/O3 I' WHITE: File YELLOW. Micant PINK: Finance Gity of CarlsbaB Final Building Instneetion Dept: Building Engineering Planning CMWD St Lite Pian Check #: Permit #: Project Name: Address: Contact Person: Sewer Dist: CB031352 PANERA BREAD 4218 SF TI 1935 CALLE BARCELONA #170 CHRIS Phone: 85851 83876 Water Dist: Lot: I m Date: Permit Type: Sub Type: 1 1 /I 212003 TI COMM 0 ....... 11..1....111.1..11..11................,......,..,,.,,.~~..,..............,.,,..,..,,.,,..,,.~~.,...,,.,,~,,.~,..,*~,,,.,,.,,..,..,...,..,..,,.,......... Inspected By: &? ,+ L:;ected: /L3 Approved: Disapproved: inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Comments: .......................I................,,,,,,,,,,~.,,,,,,*,,,,,~,~~,,,,,,,,,,~~,,,,,,,,,~,,*,,~,,,,,,,,,,~,,,~,,,~,,~,,,,,, ~,,,,,,,,,,,~,,,,~,,~,,,~,,,,,, City of Carlsbad Bldg Inspection Request For: 1 1 /2 1 /2003 Permit# CB031352 Inspector Assignment: PS Title: PANERA BREAD 421 8 SF TI Description: Type: TI Sub Type: COMM Job Address: 1935 CALLE BARCELONA Suite: 170 Lot 0 Location: APPLICANT RUSSELL STOUT Owner: Remarks: Total Time: CD Description 19 Final Structural Phone: 8585183876 f- Requested By: CHRIS Entered By: CHRISTINE Act Comment 29 Final Plumbing 39 Final Electrical t 49 Final Mechanical Associated PCRs/CVs InsDection History Date Description Act lnsp Comments 11/19/2003 89 Final Combo co PS 11/12/2003 89 Final Combo co PS 11/07/2003 39 Final Electrical CO PS EMR 11/06/2003 39 Final Electrical CA PS RESET FOR FRI BY CHRIS 11/04/2003 14 Frame/Steel/Bolting/Welding AP PS T-BAR 10/31/2003 84 Rough Combo PA PS OK TO DROP TILE/LEAVE OPEN MlSC AREAS 10/30/2003 23 GadresffRepairs AP PS 10/29/2003 23 GadresffRepairs CO PS TEST FAILED STARTED NEW TEST 10/28/2003 23 GadTesff Repairs PA PS STARTED 24HR TEST 10/28/2003 42 FluesNents NR PS 10/28/2003 43 AirCondFurnace Set NR PS 10/28/2003 44 RougNDucts/Dampers NR PS 10/28/2003 45 Hoods NR PS 10/27/2003 23 Gas/TesffR&pairs NR TP TRAILER LOCKED NO SUPP, PLNS 10/17/2003 17 Interior LatNDtywall AP TP SOFFIT / DROP CElL 10/16/2003 14 Frame/SteellBolting/Welding CO TP DROP CElL AlTACH TO STRUCT, OK TO D.W. CElL City of Carlsbad Bldg Inspection Request For: 1 1/12/2003 Permit# CB031352 Title: PANERA BREAD 4218 SF TI Description: Type: TI Sub Type: COMM Job Address: 1935 CALLE BARCELONA Suite: 170 Lot 0 Location: APPLICANT RUSSELL STOUT Owner: Inspector Assignment: PS Phone: 85851 83876 Inspector: P Remarks: Total Time: Requested By: CHRIS CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Entered By: ROBIN & Comment Associated PCRs/CVs Date 11/07/2003 11/06/2003 11/04/2003 10131/2003 10/30/2003 10129/2003 10128/2003 10/28/2003 10/28/2003 10/28/2003 10/28/2003 10/27/2003 1011 712003 1011 612003 1011 612003 1011 612003 Inspection History Description 39 Final Electrical 39 Final Electrical 14 Frame/Steel/Bolting/Welding 84 Rough Combo 23 GasTTesVRepairs 23 GaflesVRepairs 23 GasTTesVRepairs 42 FluesNents 43 AirCondIFurnace Set 44 RougNDuctsIDampers 45 Hoods 23 GaflesffRepairs 17 Interior LathIDrywall 14 Frame/SteellBolting/Welding 34 Rough Electric 44 RougNDucts/Dampers Act lnsp Comments CO PS EMR CA PS RESET FOR FRI BY CHRIS PA PS OK TO DROP TILELEAVE OPEN MlSC AREAS AP PS CO PS TEST FAILED STARTED NEW TEST PA PS STARTED 24HR TEST NR PS NR PS NR PS NR PS NR TP TRAILER LOCKED NO SUPP, PLNS AP TP SOFFIT 1 DROP CElL CO TP AP TP HARD CEIL LIGHTS AP TP DUCTSHARDCEIL AP PS T-BAR DROP CElL ATTACH TO STRUCT, OK TO D.W. CElL Nov 10 03 06:49a Patrick Rogers I > 760-804-5785 P- 1 I 1f7/03 To Whom it may concern, Mama Development Group dba, Panera Bread located at 1935 We BameIom Suite # 1 70 in Carlsbad, CA 92009, hemby requests the use of a generator for temporary electric and a temporary gas meter for the sole use of stocking the cafe with non-food items such as paper supplies, training, and stocking of smallwares. The cafe will not open for business nor allow customers to enter the cdt5 until fd permits are obtained. Ethere any questions or concerns please feel free to contact us at the information below: Panera Bread Patrick Rogers - Co-owner (858)449-8939 On-Site General Contractor Simac Construction Chris Tavulares - On-Site Superintendent (848)5 18-3876 Panera Bread Fax # @ the cafk (760)753-1723 Patrick Rogers Panera Bread City of Carlsbad Bldg Inspection Request For: 11/07/2003 Permit# CB031352 Title: PANERA BREAD 421 8 SF TI Description: Type: TI Sub Type: COMM Job Address: 1935 CALLE BARCELONA Suite: 170 Lot 0 Location: APPLICANT RUSSELL STOUT Owner: Remarks: Total Time: Inspector Assignment: PS Phone: 8585183876 Inspector: m t Requested By: CHRIS Entered By: CHRISTINE CD Description 39 Final Electrical ~- Associated PCRs/CVs Inspection History Date Description 11/06/2003 39 1 1/04/2003 14 io13112003 a4 10/30/2003 23 10/29/2003 23 10/2a/2003 23 10/2a/2003 42 1 o12a12003 43 1012a12003 44 1 o12a12003 45 10127/2003 23 1011 712003 17 1011 612003 14 10/16/2003 34 1011 612003 44 10/09/2003 14 10/09/2003 17 10/07/2003 14 10/07/2003 17 10/07/2003 24 10/07/2003 34 10/02/2003 14 Final Electrical Frame/Steel/BoltingNVelding Rough Combo Gas/Tesff Repairs Gamest/ Repairs Gaflesff Repairs FluesNents AirCondFurnace Set Roug NDuctsIDampers Hoods GasTTesffRepairs Interior LathIDrywall Frarne/Steel/BoltingNVelding Rough Electric RougNDuctsIDampers Frame/Steel/Bolting/Welding Interior LatNDrywall FrarnelSteellBoltingNVelding Interior Lath/Drywall Rough/Topout Rough Electric Frame/Steel/BoltingNVelding Act lnsp CA PS AP PS PA PS AP PS co PS PA PS NR PS NR PS NR PS NR PS NR TP AP TP CO TP AP TP AP TP co PS AP PS AP PS AP PS wc PS AP PS AP PS Comments RESET FOR FRI BY CHRIS T-BAR OK TO DROP TILEILEAVE OPEN MlSC AREAS TEST FAILED STARTED NEW TEST STARTED 24HR TEST TRAILER LOCKED NO SUPP, PLNS SOFFIT / DROP CElL DROP CElL AlTACH TO STRUCT, OK TO D.W. CElL HARD CElL LIGHTS DUCTS HARD CElL ON CEILING NOT PER PLAN ALL WALLS ONLY WALLS ONLY WALLS ONLY BACK OF HOUSE WALL ONLY I CITY OF CARLSBAD NOTICE (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE FOR INSPECT10 (760) 602-2725. RE-INSPECTION FEE DUE? a YES b PHONE @ CODE ENFORCEMENT OFFICER * I .. UNSCHEDULED BUILDING INSPECTION DATE wFL INSPECTOR PERMIT#%C!&. . PLAN CHECK # DESCRIPTION CODE ti=- DESCRIPTION ACT COMMENTS c L City of Carlsbad Bldg Inspection Request For: 09/30/2003 Permit# CB031352 Title: PANERA BREAD 421 8 SF TI Description: Type: TI Sub Type: COMM Job Address: 1935 CALLE BARCELONA Suite: 170 Lot 0 Location: APPLICANT RUSSELL STOUT Owner: Rem arks : Inspector Assignment: PS Phone: 85851 83876 Inspector: c25 t Total Time: Requested By: CHRIS Entered By: ROBIN 1 CD Description 14 FramelSteellBoltingMelding 24 Roughflopout 34 Rough Electric 44 RoughlDuctslDampers InsDection History Date Description Act lnsp Comments 09/17/2003 1 1 FtglFoundationlPiers AP PS SLAB 09/15/2003 31 UndergroundlConduit-Wiring AP PS 09/08/2003 21 UndergroundlUnder Floor AP PD ,? . - ** 1 OTICE (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAV AVENUE DATE TIME LOCATION PERMIT NO. ’f> / 7 > -z LL (760) 602-2725. RE-INSPECTION FEE DUE? 0 YES PHONE @ CODE ENFORCEMENT OFFICER San Q?goArnperial County. - 7313 Carroll Road, SOae G San Diego, CA 82121 hbnd Empire: 14320 Ekworth Street, Suite CIOI Moreno Valley, CA 92553 Anaheim. CA 92806 Tel: 714.632.2999 Tel: 858.537.3999 Tel: 909.653.4999 Fax: 714.632.2974 Fa; 858.537,.3990 Fax: 909 653.4666 FIELD REPORT WHEN A DEFfCl"CY. YOURS OR A PREVIOUS MSPECMR'Sa IS CORRECl'ED. SO NOTE OH l?lE OJZlGlNAL DEFldENCY RFJQRT AND EsGil Corporation In Partnership witd S;ovemment for Suilaing Safety DATE: 7/21/03 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-1352 a PLAN REVIEWER 0 FILE SET: 111 PROJECT ADDRESS: 1935 Calle Barcelona Suite 170 PROJECT NAME: Panera - Restaurant TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: The person responsible the plans shall stamp and sign all sheets. W By: Doug Moody Enclosures: Esgil Corporation GA 0 MB EJ PC 7/11/03 trnsrntl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 ” , EsGil Corporation In Partnership with Government for BuiGfing safety DATE: 6/5/03 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-1352 CANT JURIS. 0 FILE SET: IT PROJECT ADDRESS: 1935 Calle Barcelona Suite 170 PROJECT NAME: Panera - Restaurant TI 0 0 w 0 w 0 w 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Russell Stout & Associates 4635 Cass Street, San Diego, CA 92109 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Russell Stout & Associates Telephone #: 858-581 -281 2 Date contacted: CP [5/O_S (by:&?) Fax #: 858-272-8873 REMARKS: Mail ,Telephone Fax/ In Person By: Doug Moody Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ PC 5/9/03 tmsrntl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 I City of Carlsbad 03-1352 6/5/03 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-1352 PROJECT ADDRESS: 1935 Calle Barcelona Suite 170 SET: I DATE PLAN RECEIVED BY ESGIL CORPORATION: 5/9/03 DATE RECHECK COMPLETED: 6/5/03 REVIEWED BY: Doug Moody I] FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit three new sets of prints to: ES G I L C 0 R PO RAT1 0 N . B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo City of Carlsbad 03-1352 6/5/03 1. 3. 7. 8. 10. 11. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustriaI projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. All sheets must be signed. Please revise the plans to show the door numbers on the floor plan consistent with the door schedule on sheet A5.1. The door schedule is still inconsistent with the floor plan. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 1230# rooftop air handler units and the new oven hood. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. No Response. Provide complete plumbing plans, including: a) Please provide a drain, waste and vent plan consistent with the floor plan (no basement, auto washer, number of fixtures on grease line etc.). please revise the plans to show the additional employee restroom. Show 114" per 12" slope on drain and waste lines. UPC Section 708.0. Please revise the plans to clearly indicate all waste and drain piping to have a 2% slope. Food service establishments with an occupant load of 100 or more shall be provided with separate facilities for employees and customers. Customer and employee facilities may be combined for occupant loads less than 100. UPC, Section 41 3.6 Food Service Establishments. No Response. City of Carlsbad 03-1352 6/5/03 14. 15. 16. 17. 18. Provide complete energy designs for the proposed changes in envelope and mechanical systems. Provide the completed ENV- and MECH- forms showing energy compliance. Please provide the entire energy design package. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. Not clearly indicated on the plans. The completed and signed ENV-1 and MECH-I forms must be imprinted on the plans. Please have the author of the energy documentation sign the MECH- 1 form. Show the grab bars in detail 8 consistent with typical detail A7.2 comply with the following, per Section 11 158.8: The elevations on A4.1 are in conflict with typical details on sheet A7.2 They shall be securely attached 33” above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33”, the rear grab bar only may be installed as high as 36”. Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36” long and no more than 28” to 34” high. Section 1 122B.4. Not clearly indicated on the plans. t EsGil Corporation In Partnership with Goscrnment for Builiiing Safety DATE: 5/20/03 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-1352 SET: I PROJECT ADDRESS: 1935 Calle Barcelona Suite 170 PROJECT NAME: Panera - Restaurant TI 0 0 o w O w o w 0 0 FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Russell Stout & Associates 4635 Cass Street, San Diego, CA 92109 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Russell Stout & Associates Telephone #: 858-581-281 2 Date contacted: 5 /ZO /03 (by: Fax #: 058-272-8873 REMARKS: Mail -Telephone Fax d In Person By: Doug Moody Enclosures: Esgil Corporation GA 0 M6 EJ PC 5/9/03 tmsrntl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 . City of Carlsbad 03- 1352 5/20/03 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS 7 PLAN CHECK NO.: 03-1352 OCCUPANCY: A3 USE: Restaurant TYPE OF CONSTRUCTION: VN ACTUAL AREA: 4093sf ALLOWABLE FLOOR AREA: STORIES: 1 JURISDICTION: City of Carlsbad SPRINKLERS?: YES HElG HT: OCCUPANT LOAD: 118 REMARKS: DATE PLANS RECEIVED BY JURI SDI CTl ON : 5/7/03 ESGIL CORPORATION: 5/9/03 DATE INITIAL PLAN REVIEW COMPLETED: 5/20/03 DATE PLANS RECEIVED BY PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process. please note on this list (or a COPV) where each correction item has been addressed, i.e., plan sheet number. specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 03-1352 5/20/03 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commerciaVindustria1 projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 1. 2. 3. 4. 5. 6. 7. 8. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Provide evidence of Health Department approval (for restaurants), where regulated by the local Health Department. Please revise the plans to show the door numbers on the floor plan consistent with the door schedule on sheet A5.1. Specify lever-type hardware for passage doors on floors accessible to the disabled. Title 24. Please clarify sheet detail 15 on sheet SD-I to show the correct address, indicate on the plans the appropriate note and there location. Please attach the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. Please provide plans and calculations signed by the California State licensed engineer or architect for the structural support of the 1230# rooftop air handler units and the new oven hood. Include all calculations and finding on the plans. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Provide complete plumbing plans, including: a) Please provide a drain, waste and vent plan consistent with the floor plan (no basement, auto washer, number of fixtures on grease line etc.). City of Carlsbad 03-1352 5/20/03 b) Please revise the gas line plans and calculations to be consistent with the equipment locations shown on the floor plan, showing pipe lengths and gas demands. UPC Section 121 7.0 Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 c) 9. IO. 11. 12. 13. 14. 15. 16. 17. 18. Detail the required listed reduced pressure principle backflow preventer as protection of water connection to carbonator. UPC, Section 603.4.1 3 Show 1/4” per 12” slope on drain and waste lines. UPC Section 708.0. Food service establishments wit an occupant load of 100 or more shall be provided with separate facilities for employees and customers. Customer and employee facilities may be combined for occupant loads less than 100. UPC, Section 41 3.6 Food Service Establishments. Please note or show that all electrical penetrations into the cooler shall be sealed per section 300-7 of the NEC Please note on the plans “AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings”. Provide complete energy designs for the proposed changes in envelope and mechanical systems. Provide the completed ENV- and MECH- forms showing en erg y compliance . On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. The completed and signed ENV-1 and MECH-I forms must be imprinted on the plans. Show the grab bars in detail 8 consistent with typical detail A7.2 comply with the following, per Section 1 1 158.8: a) They shall be securely attached 33” above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33”, the rear grab bar only may be installed as high as 36“. Please revise the plans to show a disabled accessible transaction counter located at a section of counter that is at least 36” long and no more than 28” to 34” high. Section 1 122B.4. * City of Carlsbad 03-1352 5/20/03 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. CITY OF CARLSBAD POLICIES AND PROCEDURE !UMBER: 80-6 I SUBJECT: ROOF MOUNTED EQUIPMENT ZFFECTIVE: 5/1/92 S ECTl ON: BUILDING DEPARTM E NT SUPERSEDES: 80-6(9/10/80) 80-6(5/01/81) PURPOSE: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. INTENT: A. 8. C. POLICY: 1. 2. 3. 4. 5. 6. 7. Maintain roof integrity. Prevent'hazardous condition to firemen who must fight fire on the roof. Provide an installation that is aesthetically sensitive to the building and the adjoining properties.. All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department. All equipment shall be specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department. All roof mounted equipment shall be on a platform which shall be an integral part of the roof--flashed and waterproofed. When a screen is approved, it shall have as few roof connections as possible and be structurally adequste. All electrical, plumbing, mechanical duct work and related piping shall be inside the building'and not on the roof. All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official. Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in general proximity. Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official. Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, and other related appurtenances shall be removed from roof and unused openings properly sealed $0 maintain roof integrity. The architect should, through design, conceal the heating/AC unit and other equipment whether they are on the roof or elsewhere. I initiated By: City of Carlsbad 03-1352 5/20/03 YALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-1352 PREPARED BY: Doug Moody DATE: 5/20/03 BUILDING ADDRESS: 1935 Calle Barcelona Suite 170 BUILDING OCCUPANCY: A3 TYPE OF CONSTRUCTION: VN Jurisdiction Code Icb By Ordinance 1994 UBC Building Permit Fee 1 V I 1994 UBC Plan Check Fee v Type of Review: 0 Repetitive Fee 71 Repeats Complete Review 0 Other I $629.72 I I $409.32 I 0 Structural Only Hourly I I Hour * Esgil Plan Review Fee 0 Comments: Sheet I of 1 macvalue.doc PLANNING/ENCINEERINC APPROVALS PERMIT NUMBER CB OL3 - I&a DATE 6-3-03 RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR ( < $1 0,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING ,OTHER PLANNER DATE ENGINEE DATE b3-e DowMiSformflPianning Engineering Approvals PLANNING DEPARTMENT BUlLDlNG PLAN CHECK REVIEW CHECKLIST Planner Gren Fisher Phone 1760) 602-4629 Type of Project & Use: @.!-&$/#hfkt Project Density: DU/AC Zoning: - General Plan: Facilities Management Zone: CFD (in/out) #-Date of participation: APN: 32- /+ 0- we*, Remaining net dev acres: Circle One (For non-residential development: Type of land used created by this permit: 1 Leaend: Environmental Review Required: YES - DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES - APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Item Complete 0 Item Incomplete - Needs your action TYPE NO - TYPE NO - Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES- NO- - CA Coastal Commission Authority? YES- NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 921 08-4402; (61 9) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: YES- NO- Follow-Up Actions: 1 ) 2) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. NO - YES - lnclusionary Housing Fee required: (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES - NO - (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst ~___ Rev 9/01 .. Site Pian: L 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 2. Provide legal description of property and assessor’s parcel number. Policy 44 - Neighborhood Architectural Design Guidelines 1 . Applicability: YES NO 2. Project complies YES NO Zoning: 1. 2. 3. 4. 5. Setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required Shown Height: Required Shown Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Rev 9\01 031 352 'Carlsbad Fire Department 1635 Faraday Ave. Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Requirements Category: Building Plan Date of Report: 05/16/2003 Reviewed by: Name: Russell Stout Address: 4635 Cass Street city, State: San Diego CA 92109 Plan Checker: Job Name: Job Address: Job #: 031352 Panera Bldq #: CB031352 1935 Calle Barcelona Ste. or Bldg. No. 170 0 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. 0 Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1 st 2nd 3rd Other Agency ID FD Job # 031352 FD File # I Reqpiremen fs Category: Building Plan IN, I Requirement: Pending 05.34 Smoke Fire Damper requirements Provide information on the plans as to how the smoke fire dampers are to be activated. If they are to be activated by single station smoke detectors provide the locations of the detectors on the electrical plans. Also provide the state fire marshals listing sheet and the manufacturers cut sheets on the detector. I I Page 1 0511 6/03 . .. .. gESIGN ASSUMPJlO Ne: COWCRETE STRENGTH AT TWEN'lY EFQHT DAYS. MASONRY: MORT&: ' MES 1,800PSI GROUT: 2000 PSI REINPORCINO STEEL: A4t3 ORADE 40 GRADE 60 STRUCTURALSTEEL: A36 , LUMBER: DOUGLAS FtRMCH GRADE "N" CONCRETE BLOCK F ' M 2. HOROWTZ TAYLOR HTK KUSHKAKI STRUCTURAL ENGINEERS .. : .- 5v e- 61 I @ I Wm-P- NorJ -LOAD BEARING PART If IONS ! I I1 I ............................. ............................. ............................. ............................. ............................. .- . -. .-. NST FILLEQ -5. ?!'-E- 771 ............................ ............................ ............................ ........... ...-....... ..... ........................... CONTROLS FOR THE APPLICATION AND LOADS LISTED LQAOS; AiwtysiS is tor a Joist Mzmber. primary Load Group - Hoof (prf): M.0Live at 125 'Ye Uuranon. 15.0 Ooed Vertical I nads: Type Class Live O~od Locatian Application Comment Point(1bs) Rwf(1.25) 0 771 5' - laoO# Me&. Unit over 9 points unitorm(psr) Roof(l.25) 0.0 15.0 0 To 5' R~lacm NO CL IJndw Mwh. Unit SUPPORTS: lnpul Bearlng Verticat Reactions (Ibs) Ply Depth Nailing Detail Other Width Length LivelDeadrUpliWTotal Depth 1 Glulam ur solid sawn lumngr DBam 2.50" Hawr 336 I 568 I 0 I904 1 14.01' N/A ~upMWnlH81yyer None 2 GUm or solid sawn lumbei. team 2.50" Heqer 544 I471 I 0 I 101 5 1 * 14.01" NIA TOpMOuiIlHafQt3r None -Wab sUffonors xe require0 at support(s): 1.2. Sea TJI JOIST INSTALLATIBN INFflRMATlt3N It# nhiling re yirernenro. f.1 ANGERS: Simpson Strons-Ti00 Connectors support Model Slope Skew Reverse Top Flange Top Flange Support Wood flanges Offset Slope Species NIA NO 0 Owg& fir 2 Top Mount Hartger ITT311.88 -.W12 0 NIA No 0 Oouglas Fir 1 @ TopMouriLHwngW llT311.E6 -.49M2 0 -Nailing for Support 1: Face: 2-104. Top 4-1 ,Member: Z-NlO -NaiUng fw Suppon 2: Face: 2-(d , Top 4-1 8 . Mefnbec 2-N10 DESIGN CONTROLS:, Maximum Oesign Contml Control Location Shear (Ibs) -996 -996 2406 Pa$$ed (41%) Rt. end Spsn 1 under Rod loadirrg Vertical Reaction (fbs) 996 99fi 2406 Pwed (41%) Bearing 2 under Rdloebing Moment (Ft-Lbs) 5309 5300 7825 Passed (66%) MID Span 1 under Roof loading Live Load Oefl Ci) 0.497 1 .OS5 Passed (U510) MID Span 1 undw Roof toMi% . Total Load Deft (in) 1.009 1.407 Passed &/251) MID Span 1 under Roof Wins -~efbCtion Criteria: MiNiMUM(LLA./24O.TL:L/180~. -BraCing(Lu): All compression edges (top and bottom) must be braced at a' Yl"dc unless dotailad otherwise. Fwpw attachment and positioning of lateral brscing is required lo Hie membtw stability. PROJECT INFORMATION: The Fwum et Caflsbad Building E Roof Carkbad. CA SCOZEOZO64 -- Steve Bennett suite 200 Foothifl Rawh , CA 92610 Revied By: --I Phone : 9x3-455-8232 Fax : 949-616-1616 SPQC. Seclion benneba@trusioistcm 5 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLtCATtON AND LOADS LISTED Member flops: ..49'12 ROO? Slope-A9:12 - ..-. 4 I SUPPORTS: lnpul Bearing Vertical Reactions (lbs) Ply Depth Nailing Docail Width Length LivelDeadlUpliftlTolal Death Other 1 GIulam of solld sawn lumber boam 2.50" HailgtY 710 / 734 / 0 I 1444 1 14.01' Nfc\ TopMoulltHanger None 2 Glularn or solid sawn luiith I beam 3.54 Hangar 637 I 563 10 I 1200 I 14.01" NIA TopMoiintHanger Nonc 7, -Web stiffeners are required al support(s): 1.2. Set! TJI JOIST INSTAI.CATION INFORMATION for nailin9 retyiements. HANGERS: SimDron StrOnq-Tie@ Connectors support Model Slopc Skew Reverse Top Flange Top Flange Suppart Wood 1 TopM~~~ntHaWFler iTT314. -.49/32 0 NIA NO 0 Dguglab Fir Flanges Offset Slepe Specles . 2 @ TopMountHanger ITT314. -.49112 0 NIA No 0 Dwglas Fi -Nail-- fa Support 1: Fee 2-1W . Top 4-1Od I Member: Z-NlO -Nailing fw Suppoft 2: Face: 2-1W , rop 4-10d . Member: 2-Nl0 pESIGN CONTROLS: Meximum Debipn Control Control Location she3 fibs) 1425 1425 2656 passtd (54%) LL end Span I under Roof loadin2 Vertical Reaction (Ibs) 1425 1425 2656 Passed (54%) Bearing 1 under Roof loadinq Live Load Dell [in) 0.479 1.059 Passed (U530) MID Span 1 under Roof Wq Total Load Oen (in) 0.065 1.112 Passed (u263) MID SF 1 wwler Roof l0ad.k~ Moment (FtLbs) 7366 1356 WB pamed(77#) MIOSpan1 unbc?rROOfm . ' -0eflection Criterie; MINIMUM(~L:U240.TL:U180). -Bnclng(Lu): All compression edges (tap awl boUon\) must be braced at T 11' dc unless detaiW othwiW. Roper a(tadtment and paoldOfhg O! bterel bracing is raquired to achieve memer slab8sry. PROJECT [NFORMATION: Tha Forum at Carlsbad Buikfii 8 Roof Carlsbad. CA SC02E02064 OPERATOR INFORMATI* Swe Bennrtn TNS Job1 27042 TOWIX? Centre Drive Suite 200 Foothill Ranch. CA 92670 Phone : 9494558252 Oennetsa@trusjoisLcorn FW : 949-616-1616 1 YANERA, LLC. 935 CALLE BARCELONA E FORUM AT CARLSBAD IARLSBAD, CA 92009 PROJECT DIRE( __ REFERENCE MA d .Ql L\ 2 4 el' E x . .-_ CC $2 P. 4 a 1 3r 3 t" v c't t- u) 12-01 -2003 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Building Inspection Request Line (760) 602-2725 Permit No: PCR03204 Job Address: Permit Type: PCR Status: ISSUED Parcel No: Lot#: 0 Applied: 09/17/2003 Valuation: $0.00 Construction Type: NEW Entered By: MDP Reference #: CB031353 Plan Approved: 09/25/2003 Issued: 12/01/2003 Project Title: PANERA BREAD Inspect Area: 1935 CALLE BARCELONA CBAD REVISE DETAIL 4, SHT A7 Applicant: FLINER MIKE Owner: Plan Check Revision Fee Additional Fees $90.00 $0.00 Total Fees: $90.00 Total Payments To Date: $0.00 Balance Due: $90.00 FINAL APPROVAL InsDector: Date: Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "feeslexactions.' You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified feeslexactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any feeslexactions of which vou have oreviouslv been aiven a NOTICE similar to this. or as to wh ich the statute o f limitations has oreviouslv otherwise exoired. 12-01 -2003 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: FLINER MIKE 858 581-2812 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Building Inspection Request Line (760) 602-2725 Permit No: PCR03204 1935 CALLE BARCELONA CBAD PCR Status: ISSUED Lot#: 0 Applied: 09/17/2003 $0.00 Construction Type: NEW Entered By: MDP CB031353 Plan Approved: 09/25/2003 Issued: 12/01/2003 PANERA BREAD Inspect Area: REVISE DETAIL 4, SHT A7 Owner: Plan Check Revision Fee Additional Fees $90.00 $0.00 Total Fees: $90.00 Total Payments To Date: $0.00 Balance Due: $90.00 FINAL APPROVAL Insoector: Date: Clearance: ~ ~ ~ ~~~~ ~~ ~ NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'feeslexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified feeslexactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any feeslexactions of which YOU have Dreviouslv been aiven a NOTICF similar to this. or as to wh ich the statute o f limitations has oreviouslv otherw ise exDired. FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHECK NO. y Plan Ck. Deposit ,- Cln OF CARLSBAD BUILDING DEPARTMENT Legal Description Lot No. Subdivision NamelNumber Unit No. Phase No. Total # of units Existing Use Proposed Use Assessor's Parcel I Name Address City Statelzip Telephone # WME Name Address City Statelzip Telephone # (Sec. 7031.5 Business and Professions Coda: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars I$5001). Name Address City Statelzip Telephone # State License # License Class City Business License # Designer Name Address city Statelzip Telephone 0 of the work for which this permit is issued. 0 issued. My worker's compensation insurance carrier and policy number ara: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ~8100.000~. in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, Interest and attorney's fees. SIGNATURE DATE I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is 0 I. as owner of the property or my employees with wages as their sole compensation. will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however. the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Coda: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(sl licensed pursuant to the Contractor's License Law). 0 1. 2. 3. 4. number I contractors license number): 5. of work): I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ON0 I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide tha major work (include name / address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address I phone number I type Business and Professions Coda for this reason: - PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed withm 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. EN I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Coda). LENDER'S NAME LENDERS ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit). of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit authorized by such permit is not co at any time dter the work is co APPLICAN'T S SIGNATURE itation and become null and void if the building or work k authorized by su h per it is suspended or abandoned DATE ?j7J-3 6.4.4 Uniform Building Code). EsGil Corporation In Partnership with Government for Builiiing safety a BNT DATE: 9/23/03 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 03-1352.PCR03-204 SET: I 0 PLAN REVIEWER 0 FILE PROJECT ADDRESS: 1935 Calle Barcelona PROJECT NAME: Panera Bread- Revision to Floor Slab The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: REMARKS: By: Doug Moody Enclosures: Mail Telephone Fax In Person Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 911 7/03 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 03-1352.PCR03-204 9/23/03 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad 204 PLAN CHECK NO.: 03-1352.PCRO3- PREPARED BY: Doug Moody DATE: 9/23/03 BUILDING ADDRESS: 1935 Calle Barcelona BUILDING OCCUPANCY: A3 TYPE OF CONSTRUCTION: VN Air Conditioning Fire Sprinklers I ! ! 1 ! 1 Jurisdiction Code Icb By Ordinance 1994 UBC Building Permit Fee I V 1994 UBC Plan Check Fee 4 Type of Review: 0 Complete Review 0 Structural Only 0 Repetitive Fee El Repeats I7 Other Hourly 1 0.751 Hour* Esgll Plan Review Fee I $90.001 Based on hourly rate Comments: I Sheet 1 of 1 macvalue.doc