Loading...
HomeMy WebLinkAbout1935 CAMINO VIDA ROBLE; ; CB900826; PermitBUILDING PERMIT 06/07/90 08:18 Page 1 of 1 Job Address: 1935 CAMINO VIDA ROBLE Permit Type: INDUSTRIAL TENANT IMPROVEMENT Parcel No: 212-092-18-00 Valuation: 29,914 Construction Type: NEW Occupancy Group: B2 Class Code: Description: 1554 SF OFFICE REAL ESTATE OWNER : REAL PROPERTY SERVICES *** Fees Required *** *** Str: Permit No: CB900826 Project No: A8800184 Development No: Fl: Ste: 5975 06/07/90 000! 01 (V Status: ISSUED Applied : 05/18/90 Apr/Issue : 06/07/90 Validated By: CD Lie. 619 431-9100 Collected & Credits *** Fees : Adjustments: Total Fees: Fee description 1, 560 1, Building Permit Plan Check Strong Motion Fee Enter 'Y' to Autoc * BUILDING TOTAL Enter "Y" for Plum Enter "Y" for Elects Remodel/Alter Per * ELECTRICAL TOTAL Enter 'Y' for Mechani Install Furn/Ducts * MECHANICAL TOTAL Total Credits: Total Payments: Units Fee/Unit . 00 185.00 1,375.00 Ext fee Data " * A% fe Tax >* /^9& > 'N'fi^ > **• > 40.00 .25 l^uraf :|i% Fee>s •*;(/; > l.jOO 9.00 285. 185. 4. 1047. 1521. 5. 10 . 15. 15. 9. 24. 00 00 00 00 00 00 00 00 00 00 00 Y N Y Y APPROVAL, iTP ffJ he CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Us Palmas Dr., Carlsbad, CA 92009 (619) «8-ii6i 1. > PERMIT TYPE A - KTCOMMERC1AL GNEW tHTENANT IMPROVEMENTS~t *^~\ B - QlNDUSTRIAL ONEH Q TENANT IMPROVEMENT c - PRESIDENTIAL DAPARTMENT ncoNoo QSIKGIE FAMILY DWELLING QADDITION/ALTERAIION PDUPLEX DDEMOLITION QRELOCATION IMMOBILE HOME QELECTRICAL n«ECHANICAL D^OOL QSPA DETAINING WALL QSOLAR QOTHER, 2.PROJECT INFORMATION PLAN CHECK 'jf A i - *i /No. /£/ W^FOR OFFICE USE ONL Y Address f<Sfgg <ZAST?/*/0 Vl&A «/?EST. VAL Of />'<?/£ PLAN CK DEPOSIT /Q -^ VALID. BY 7*) CL DATE / f^/ffr/t 1} •MT Nearest Cross Streets I/T LEGAL DESCRIPTION ivision Name/ Number Phase No. CHECK BELOU IF SUBMITTED: [2 Energy Calcs D2 Structural Calcs ~AKEfiSOR'S PARCEL DESCRIPTION Or WORK Soils Report Addressed Envelope EXISTING USE PROPOSED USE •/MS// o/* BLDG. SO. FTG,# OF STORIES 3. CONTACT PERSON NAME DAGENT FOR CONTRACTOR ADDRESS STATE ZIP CODE DAY TELEPHONE 5. PROPETY OWNER STATE ADDRESS ZIP COPE QLESSEE QTENANT DAY TELEPHONE 6. CONTRACTOR NAME STATE STATE LIC. 0 ADDfiESS ZIP CODE LICENSE CLASS DAY TELEPHONE CITY BUSINESS LIC. * SIGNATURE DESIGNER NAME CITY 7. WORKERS'COMPENSATION TITLE ADDRESS STATE ZIP CODE DATE DAY TELEPHONE STATE LIC. # Workers' Cornjensat\on Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO.EXPIRATION DATE Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manrier so as to become subject to the workers' Compensation Laws of California. .DATE 8. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: [~1 ! as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). * I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [S500] ). SIGNATURE I g//8/«?O COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PTEHMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley -Tanner Hazardous Substance Account Act? DYES ^NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ^NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES J^ NO IF AKT OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY NAT NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AMD THE AIR POLLUTION CONTROL DISTRICT. _ 9. CONSTRUCTION LENDING AGENCY _ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE I certify that 1 have read the application and state that the above information is correct. 1 agree to comply with all City ordinances and State laws relating to building construction. 1 hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). OUNER OCONTRACTOR QBY PHONE APPROVED er: DATE: WHITE: File YELLOW: Applicant PINK: Finance PERMIT* CB900826 DESCRIPTION: 1554 SF OFFICE CITY OF CARLSBAD INSPECTION REQUEST FOR 08/17/90 REAL ESTATE TYPE: ITI JOB ADDRESS: 1935 CAMINO VIDA ROBLE APPLICANT: AUSTIN HANSEN FELHMAN CONTRACTOR: OWNER:REAL PROPERTY SERVICES STR: PHONE: 4581361 PHONE: PHONE: 619 431-9100 INSPECTOR INSPECTOR AREA MC PLANCK* CB900826 OCC GRP CONSTR. TYPE NEW FL: STE: REMARKS: T3/MH/JERRY SPECIAL INSTRUCT: HE WOULD PREFER THAT TO HAPPEN RIGHT AFT$R LUNCH. TOTAL TIME: CD LVL DESCRIPTION 19 29 39 49 ACT COMMENTS ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ***** INSPECTION HISTORY ***** DATE DESCRIPTION 081590 Frame/Steel/Bolting/Welding 081590 Rough/Topout 081590 Rough Electric 081590 Rough/Ducts/Dampers 073090 Interior Lath/Drywall 072790 Frame/Steel/Bolting/Welding 072790 Interior Lath/Drywall 072590 Frame/Steel/Bolting/Welding 072590 Frame/Steel/Bolting/Welding 072590 Rough Electric 072590 Rough/Ducts/Dampers ACT AP CO AP CO AP CO PA AP CO AP NR INSP MFC MFC MFC MFC MFC MFC MFC MFC MFC MFC MFC COMMENTS CEILING GRID SYSTEMS NDS CONDENSATE & 0/F DRN LNS CEILING NDS SEISMIC SUPPORTS FOR RAR SEE COMMENTS 7/30/90 NDS REV PLANS SUBMITTED FOR 0 WALLS NDS INSUL LOW WALLS NDS STIFF WALLS ONLY DATE: JURISDICTION: PLAN CHECK NO ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-1468 fc) 9 / SQuv> SET:ev/. PROJECT ADDRESS; (32>S Qg-vnt\\6 \Ar(gL PROJECT NAME: RgAji&ggj Dyi^eyt^x^ (jQgiiI PI APPLICANT JURISDICTIONS QPLAN CHECKER QFILE COPY QUPS QDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: REMARKS: Telephone # By: u^(lL ESGIL CORPORATION DGA DAA Dvw QDM Enclosures DatenS/9/Sto Jurisdiction Prepared byi PLAN CHECK NO _____ BUILDING ADDRESS _i92>g APPLICANT/CONTACT BUILDING OCCUPANCY VALUATION AND PLAN CHECK FEE Q Bldg. Dept, D Esgil . 9O~ n _ V(r(<g, QihfYT^A PHONE NO. TYPE OF CONSTRUCTION DESIGNER PHONE CONTRACTOR PHON BUILDING PORTION BUILDING AREA * Air Conditionine Commercial Residential Res. or Comm. Fire Surinklers Total Value Building Permit Fee $_ Plan Check Tee $ C 0 M ME NTSt SHEET OF 12/87 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-1468 DATE 90 JURISDICTION: PLAN CHECK NO:SET : IT PROJECT ADDRESS: 193>S P/lVY\\Y\Q APPLU JURISDICTION jPLAN~~Cl QFILE COPYOUPS HDESIGNER PROJECT NAME:of r-\\e< Services 1J. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified W") -nfl^ TP7AarKi Of.IO'AJ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. |—I The applicant's copy of the check list is enclosed for the •—I jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the pla been completed. Person contacted: vTc^rXV heck has Date contacted: REMARKS : t \.n*V By: ESGIL CORPORATION DGA DAA Dvw RDM Datei Prepared bytcu PLAN CHECK NO. Jurisdiction CARLSBAD VALUATION AND PLAN CHECK FEE n Bldg. Dept. D Esgil BUILDING ADDRESS 1C)?>S C^VtWyA APPLICANT/CONTACT BUILDING OCCUPANCY __ TYPE OF CONSTRUCTION ^VtyA l<^ r e Ol-hV!'3Y\ PHONE NO. 4^1- 9 DESIGNER PHONE CONTRACTOR PHONE. BUILDING PORTION I T-L.' Air Conditioning: Commercial Residential Res. or Comm. Fire Sprinklers Total Value BUILDING AREA 4-y_-r-<iKr ^ r> i-vS4-I VALUATION MULTIPLIER tO -o c—i>'(-C2.S I^2J=T '@ ••5 e • • VALUE ^L , Q^ s~\ ^•^s c. X- CJ 2.9 9 ^ O->91A- . -^ 1 Q ri j-£>| o2.O Building Permit Fee $_ Plan Check Fee $ COM MENTSj SHEET I OF ( I A 1 FINAL BUILDING INSPECTION RECEIVED AUG 2 2 1990 DEPT: BUILDING ENGINEERING ffiffi* PLANNING U/M WATER PLAN CHECK*: CB900826 DATE: 08/17/90 PERMIT*: CB900826 PERMIT TYPE: ITI PROJECT NAME: 1554 SF OFFICE REAL ESTATE ADDRESS: 1935 OIWSHQ VISA ROBLE £ CONTACT PERSON/PHONE*: T3/MH/JERRY SEWER DIST: WATER DIST: INSPECTED DATE BY: L\ fS^OoL^ INSPECTED: O/im*tO APPROVED P— DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DiEGO, CA 92123 (619) 56O-1468 DATE:APPLICANT ICTION: CARLSBAD HECK NO: c T ADDRESS : | 9 2 IT NAME: ReCL\ 3C)-&.CL6^ SET: X >5 GcLY)i'i'i)r> Vlirlr^ R< Pto HPT W^ rennet \ > TT _JPLAN CHECKERQFILE COPY QUPS QDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. U3 The applicant's copy of the check list has been sent to: VJir Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: REMARKS: Telephone fry (Enclosures ESGIL CORPORATION £ DGA DAA Dvw QDM FLAN CHECK NO.: PLAN CORRECTION SHEET TENANT IMPROVEMENT Date plans received by jurisdiction: .TngTSDICTIQH: CARLSBAD TO: r. C/7 r OCCUPANCY: PROJECT DATA D _0_ BUILDING DSE:0•*~.s TYPE OF CONSTRUCTION: _ 1 (oS^. U I. (3 T- \ V /ACTUAL AREA: ALLOWABLE AREA:. STORIES: HEIGHT: SPRINKLERS: OCCUPANT LOAD:n REMARKS: Date plans received by Esgil Corporation: I I Date initial plan check completed: ! ! ^. •f~\\ \**\ / "o, /^\ .' ' \r , , x-> ,•J • yO Bv;O'UC C. T Applicant contact person: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and accessf orthe The circled items listed need clarification, modification or change. All items must be satisfied before the plans will be in confonnance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP the recheck process* note on this list for a COPY) where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked UP list when you submit the revised plans. NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. LIST NO. 56 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC © © © Q Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation ..of the plans. Section 302(d). Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 302(d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. On the first sheet of the plans indicate: Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B. A complete description of the activities andprocesses that will occur in this tenant spaceshould be provided. -A—lie ting &f-—ail hnaagdouo Botorialc chould-be—inaiuded.—33*e materials 'Hating—should bo—stated- in a-form •that wouM—moke elaooification—in Tablon 9-A nfP*t*l «•wav require- a— -technical ..... fcpoffe — fee — identify and dovolop — a»thodc — o£. protection from hazardous materials-. — Sootion 9Q If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1987 NEC. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being iinproved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls. 12/29/89 Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. 23.) Provide a section view of all new interior partitions. Show: Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral-load). Wall sheathing material and details of attachment (size and spacing of fasteners), Show height of partition 'and--suspended ceiling, and—height from floor to roof framing M floor -framing. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard material extending five inches Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within compartments. Section 510(b). non-absorbent up the wall. water closet 25.) Note on the plans: "All interior finishes must comply with _ Chapter 42 of the UBC". Specify "Class "TTJ^I flame spread rating (minimum) for (26.) Lateral bracing for suspended ceiling must be provided. (UBC Table 23-P) Where ceiling is not supporting interior partitions, ceiling bracing shall be provided by four No. 12 gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 90 degrees from each other at an angle not exceeding 45 degrees from the plane of the ceiling. A strut (adequate to resist the vertical component from lateral loads) fastened to the main runner shall be extended to and fastened to the structural members of the roof or floor above. These horizontal restraint points shall be placed 12 feet o.c. in both directions with the first point within 6 feet of each wall. Attachment of restraint wires to the structure above shall be adequate for the load imposed. UBC Standard 47-18. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(f). In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 25l6(f). Storage areas exceeding 1000 sq. ft. in connection with wholesale or retail sales shall be separated from the public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet. Section 3802(c). The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. Seg—-the attacned correction sheet* Title 24, Part 2.~ The width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. 33, ] Specify lever-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes vill be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 705. In areas where the occupant load exceeds two exits are required. See . Table 33-A. 2/15/90 /•/• /• /• Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Exits should have a minimum separation of one- half the maxijDum overall diagonal dimension of the building or area served. Section 3303(c). The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303(a). Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 3303(e). Exit signs are required for exits serving an occupant load exceeding 49. Show all required exit sign locations. Section 3314(a). Show that exits are lighted with at least one foot candle at floor level. Section 3313(a). Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3304(c). Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(f). Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3303(b). Applies to door(s) Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access). Section 3304(i). Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock unless it is panic hardware. Section 3318. Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection to the exterior of the bui Id ing. Interruptions by an intervening room is not permitted.' Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving 10 or more occupants must be a minimum W* inches wide and 7 feet high to the lowest projection. Corridors serving less than 10 occupants must be a minimum of 36 inches in width. Section 3305(b). When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall have walls arid ceilings of one-hour construction except: a. Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. b. c. Exterior sides balconies. of exterior exit Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Section 3305 (g). Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3305(g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). 2/14/90 Section 3305(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings *"*•" "'— * *•*•-- levels. into them from other If non-rated corridors are used per Section 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: 1. 2. 3. Corridors are non-rated per Section 3305(g), Exception 5. Smoke detection system must be listed by the State Fire Marshall and be a supervised low voltage system. Smoke detectors center. shall be maximum 30' on 4. Combined audible/visual signal device(s) shall be installed just inside of each exit door from the corridor, also all locations in the corridor must be in sight of a signal device. This is a State Fire Marshall requirement and applies to: high- rise buildings, A/E/I occupancies, State- owned buildings, residential care homes, hotels, motels, apartments and condominiums. Any questions regarding this should be directed to the local Fire Department. 5. Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. 60. Clearly show where the non-rated corridor system terminates and a rated corridor system commences. 61.) One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 ninutss, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on si<jes and top. Section 3305(h). ME.UG .ow rated corridors, lobbies, recepion or foyers cross-hatched on the floor plans. Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed, approved 1/4 inch thick wired glass installed in steel frames. Section 3305(h). Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor walls and ceilings. Section 4306(j). If a room with an exhaust fan has a door opening into a rated corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)l. If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. If a second door is provided at the elevator entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort. Section 5106. Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment). When nonflammable supply cylinders for medical gas systems are located inside buildings, they shall be in a separate room or enclosure separated from the rest of the building by not less than one-hour fire-resistive construction. Doors to the room or enclosure shall be self-closing smoke- and draft-control assemblies having a fire-protection rating of not less than one hour. Rooms shall have at least one exterior wall in which there are not less than two vents of not less than 36 square inches in area. One vent shall be within 6 inches of the floor and one shall be within 6 inches of the ceiling. When an exterior wall cannot be provided for the room, automatic sprinklers shall be installed within the room and the room shall be vented to the exterior through ducting contained within a one-hour- rated shaft enclosure. Approved mechanical ventilation shall provide six air changes per hour for the room. Section 702(b)4. 2/H/90 (72.) yf. ,?£. M^ T&. 77. 7$. / (0. ET.ErrrpTr.At. Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. Indicate wiring method, i.e. EMT, metal flex. Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314 of the 1988 UBC, provide two sources of power to exit signs and exit illumination. Provide receptacle(s) within 25' of the roof mounted A/C units. UMC Section 509. Provide multiple switch lighting controls per Title 24, 2-5319. Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54. MECHANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment. Detail access equipment. and working clearances to HVAC Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged. Section 1205, UMC. One-hour corridors shall not be used as an integral part of a duct system. This includes the space above a dropped ceiling within the one-hour corridor. UMC Section 706(b). FLUMBIWG 11. Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1219. f8. Provide drain, waste and vent plans. Provide water line sizing calculations. UPC Section 1009. Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor drain trap priming). Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 1007(e). Show 1/4" per 12" slope on drain and waste lines. UPC Section 407. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 605. 94.) Provide complete energy design calculations, including all existing design and new energy design for this building. See attached non- residential energy design checklist. For remodels in an existing conditioned space, show that the remodeled space will use not more energy than the existing space or show the remodeled space will conform to latest energy design standards. CITY OF CARLSBAD SUffLEMEKT Floor drains must have auto-prime (City Policy). A grease interceptor is required. Show details complying with City Policy 83-34. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). Condensate drains must connect to a wet trap (dry traps are not permitted). (Memo 1/14/83). Show fans are duct type; City Policy does not permit ductless fans. Romex is not permitted in industrial or csoasrciai buildings. (City Policy) No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official. (City Policy) All panel boards shall have a minimum 100 amp rating or approved by the Building Official. Fbrw -fe r V/- Calcfe- ate T C-SO s-tf.-ft.frf -Vi ooru 2/28/90 The minimum 100 amperes. rating of a service disconnect is 105. The minimum size conductor to receptacles and / lighting fixtures in commercial and industrial buildings shall be #12 Cu. X-AC(BX) cable is not allowed in group A, B, E, H and I occupancies, (see Ord. for exception) 7. Please see additional corrections or remarks that follow. WftJ. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 9. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No NOTE: The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall. They are provided here as a courtesy to assist designers in developing the project documents. All applicable provisions may not necessarily be included. Please direct any questions regarding interpretations of these provisions to the local Fire Department. fl. Walls of corridors and exterior exit balconies in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction. Section 3305(g)l. Where exit signs are required by Section 3314(a), approved and listed internally, externally or self-illuminated low-level exit signs complying with Section 3314 shall be required. The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level. For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door. Such signs shall be of a type which is perceptible to the sense of touch. Section 3314(e). Where exit signs are required by Section 3314(a), all exit corridors shall be provided with continuous low-level exit path marking. Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level. Such marking shall be of a type which is perceptible to the sense of touch. Section 3314(f). Area separation walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38. Section 505(e)6. EXCEPTION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from us ing area separation walIs in 1ieu of automatic fire-sprinkler protection. In educational occupancies, storage and janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). Section 1807 should be reviewed for all high- rise buildings. The exception in Section 3318 of the UBC has been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. If emergency warning systems are required, they shall activate a means of warning the hearing impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact r at Esgil Corporation Thank you. Enclosures: 1. 2. 2/28/90 TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction CjQ r (A pg rl ' * Plan Check No. 9O~ g References to section numbers with prefix "2" are to Title 2k, California Code of Regulations, Part 2 (California Building Code). Prefix "3" is for Part 3 (California Electrical Code). Prefix "5" is for Part 5 (California Plumbing Code). Exemptions claimed for any item shall be requested in writing and shall include all data needed to determine "unreasonable hardship" as described in Section 2-J+22. SITE DEVELOPMENT I. ^ HANDICAPPED PARKING SPACES a. Provide -. handicapped spaces 2-7l02(b) b. Space shall be so located that handicapped persons are not compelled to wheel or walk behind parked cars other than his/her own. 2-7102(c) c. Parking space shall be a minimum of 9 ft.xlS ft. with adjacent marked 5 ft. loading zone. Double space shall be 23 ft. wide. Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle. 2-7102(c). d. Maximum slope of parking surface in any direction shall not exceed 1/4" per foot. 2-7102{e). e. Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the parking stall). 2-7102(f) f. Entrance to parking area (or at each stall) shall have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away. 2-7102(f) g . Entrance to and vertical c learance within accessible. level of parking structure shall be 8 ft. 2 in. to any structural member, duct or pipe. 2-7102(g) 2. ) CURB RAMPS a. Curb ramps shall be located wherever pedestrian path crosses curb. (2- 7103(a)) b. Curb ramp shall be 48" min. width (2- 7103(b)) with maximum slope of 1 in 12. 2-7103(d) c. A level 48" min. depth landing is required at top of curb ramps over entire curb ramp width. 2-7103(d) d. If no landing is provided, the slope of flared sides shall not exceed 1 in 12. 2-7103(d) e. Surface, is to be slip contrasting finish sidewalk. 2-7103(f) resistant and a from adjacent f. Border markings shall be 12" wide of l/4"xl/4" grooves, 3/4" apart, located at top and sides. 2-7103(h) WALKS a. Site development and grading shall be designed to provide access to prijnary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-7101(a) b. Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec. 2-3307. 2-3325(c) c. Walk width shall be 48" minimum, and shall have slip-resistant surfaces. 2-3325(a) d. The maximum cross slope shall not exceed 1/4" per foot. 2-3325(a)3 e. Gratings are not possible. ~2-3325(b) allowed whenever © f . At each gate or door a 60"x60" level area is required when the gate swings toward the walk. 2-3325(e) g. A 48"x44" deep level area is required when the gate swings away from the walk. 2-3325(e) h. A 24" clear space is required at strike side of gate or door. 2-3325(e) PEDESTRIAN RAMPS Accessa. A path of travel with a slope greater than 1 in 20 shall be considered a ramp. 2-3307 (a) b. The maximum slope shall be 1 in 12. 2-3307(c.l) c. The width shall be 48" minimum. A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more. Group R Occupancies may be 36" when the occupant load is 50 or less. 2- 3307(b.l) k. Width of clear area on the swing side of the door shall extend 2V past strike jamb for exterior doors and 18" past strike jamb for interior doors. 2-330i(i.l) 1. The space between two consecutive doors (vestibule) shall provide a minimum of 43" clear depth between the open door and a second closed door. Doors in a series at a vestibule shall swing in the sane direction, or away from the space between them. 2-3304(i.l) m. For corridors over 200 feet long, see special requirements of Sec. 2-3305(b)2. S. FLOORS a. Floors of a given story shall be a c omaon 1 eve 1 throughout or shal 1 be connected by pedestrian ramps, passenger' elevators, or s pecial access lifts. 2-522(e) STAIRWAYS NOTE: Only applies where disabled access is provided or required to other levels. a . Treads shal 1 have smooth , rounded exposed ecees and be slip resistant. 2- 3306(5) b. Nosing shall not project more than 1-1/2 inches past face of the riser below. 2-3306(s) c. Risers shall be sufficiently solid. 2-33Q6(s) d. The upper approach and lower tread of each flight of stairs shall be marked with a contrasting colored strip 2" in width. 2-3306{r) e. On exterior stairs, each tread shall be marked as noted above. 2-3306(r) f . Handrails are required on each side of stairway. 2-3306 g. Handrails shall be located 30" to 3V above nosing, extend 12" beyond top riser and 12," plus tread width beyond bottom nosing and returned to wall/newel post. 2-3306(j.l). h. Handrails shall be 1-1/4" to 2" in gripping cross section and 1-1/2" clear of wall. 2-3306(j.l) i. Approved stairway identification signs shall be located at each floor level in all enclosed stairways in buildings two or more stories in height. The sign shall identify the- stairway, indicate whether there is roof access, the floor level, and the upper and lower terminus of the stairway. The information shall be presented using raised Arabic numerals and raised braille symbols which conform to Section 522(b)3. The sign shall be located approximately 5 feet above the floor landing iiamediately adjacent to the door on the strike side. Signs shall comply with requirements of U.B.C. Standard No. 33-2. 10. ELEVATORS a. Provide clear inside elevator car dimensions as required bv U.B.C. Section 5103(d) 6 and Title 24 2-5103(d.l). 1. At least one elevator in buildings 4 or more stories in height: 80" by 54", with a 42-inch side slide door. Applies only to: high-rise buildings, A/S/I occupancies, State-owned buildings, residential care homes, hotels, motels, apartments and condominiums. 2. Elevator in buildings more than two stories or buildings where disabled access is required to upper level(s): 68" by 54", with a minimum clear door width of 36". 3. Elevators other than in (b) above serving less than 50 occupants shall have a minimum inside platform of 4 feet 6 inches by 4 feet 6 inches and a minimum clear door width of 36 inches. b. Raised Braille markings and Arabic numerals are required on control buttons and door janbs. 2-5103(d.l) SAHTEAKY FACELITIZS TOILET FACILITIES ACCESS a. When located on accessible floors, . sanitary facilities shall be made accessible to physically handicapped. (2-511.l(a)) b. Doorways shall have 32" minimum clear opening width. 2-511.1 c. There shall be a level area with 60" clear depth in the direction of the door sving, and a level area with 44" clear depth in opposite direction of door swing. 2-511.l(a) (12.JMULTIPLE ACCOMMODATION TOILET FACILITIES a. Provide clear area 60" diameter x 27" high - or clear space 56" x 63" x 27" high. 2-511.l(a) b. Doors (other than handicap compartment) are not to encroach more than 12" into above mentioned clear space. 2-511.l(a) c. Provide a 28" clear space between water closet and fixture or 32" clear space between water closet and wall. 2-511.l(a) d. A 48" long clear space is required in front of water closet. A 60" clear space is required when the toilet compartment has a side door. 2-511.l(a) e. Water closet compartment door to provide 32" clear width for end entry and 34" clear width for side entry. Door to be self-closing. 2-511.l(a) SINGLE ACCOMMODATION TOILET FACILITIES a. Water closet shall be located 28" from a fixture or 32" from a wall. 2-511.l(a) ., b. Minimum clear space in front of water closet shall be 48". 2-511.l(a) c. In an existing building, a single accommodation toilet facility may have a space 36" wide x 48 " long in front of water closet. 2-511.l(a) 16. URINALS U ./GRAB BARS AT WATER CLOSET a. One at side 42" long extending 24" in front of water closet j one at rear 36" long centered on water closet; both mounted 33" above floor. Where a tank- type toilet is used, grab bar may be as high as 36". 2-511. l(a) b. Bars shall be 1-1/4" to 1-1/2" in diameter with 1-1/2" clearance to wall. 2-511. l(a) c. Bar fasteners- and mounting support shall be able to withstand 250 Ibs./ft. in bending, shear and tension. 2-511. l(a) .IS.VATER CLOSET a. Height of water closet seat shall be 17" to 19" above floor. 5-1502 b. Controls shall be ' operable with one hand , and shal 1 not require tight grasping, pinching or twisting of the wrist. 5-1502 c. Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 44" above the floor. 5-1502 d. The force required to activate controls shall be no greater than 5 pounds force. 5-1502 a. Where urinals are provided, the rim of at least one shall project 14" from the wall and be located 17" maximum above floor. 5-1503(a) b. The force required to activate the flush valve shall be 5 Ibs. maximum and located 44" maximum above floor. 5-1503(b) c. Provide 30" x 48" clear floor space for forward approach. 1-511. l(b) l7.) LAVATORIES a. Provide 30" x 48" clear floor space for forward approach. Said clear floor space may include knee and toe space under lavatory described below. 2-511. l(b) b. Provide clear space beneath lavatories 29" high by 30" wide by 8" deep at top and 9" high by 30" wide by 17" deep at bottom from front of lavatory ( toe space) . The maximum counter surface height should be 34". 5-1504(a) c. Hot water and drain pipes lavatories shall be insulated. 5-1504(b) under d. Faucet controls and operating mechanism (operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 Ibs. 5-1504(c) e. If self-closing valves are used, they shal 1 remain open for at least 10 seconds. 5-1504(c) 18?TOIL£I ROOM ACCESSORIES a. Mirror bottom edge shall be located 40" maximum above floor. 2-511. l(b) b. Toilet tissue dispensers shall be mounted within 12" from the front edge of toilet seat. 2-511. l(b) c. Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc.) shall be within 40" of floor. 2-511. l(b) ( 19. J SANITARY FACILITIES IDENTIFICATION a. On doorways leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" diameter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color. Unisex facilities shall be identified by the circle with the triangle superimposed within the circle. 2-511. l(a) < DINING, BANQUET AND BAR FACILITIES a. Access shall be provided at primary entrances. 2-611(d) b. Wheelchair access shall be provided to all areas where each type of functional activity occurs. 2-611(d) c. This facility requireswheelchair seating spaces. ', d. At least one wheelchair seating space shall be provided for each dining, banquet and bar area. 2-611(d) e. Access to wheelchair seating spaces shall- be provided by 36" minimum clear width main aisles. 2-611(d) f. Cafeteria line aisles shall be a minimum of 36" clear width. 2-611(d) g. Access to food preparation areas shall comply with provisions for entrance doors and doorways contained.in Section 2-3304. 2-611(d) h. Restrooms and powder rooms shall conform to the requirements in Section 2-511. 2-611(d) f8. RELIGIOUS FACILITIES a. Sanctuary areas shall be accessible. 2- wheelchair seatingb. Provide _ spaces in the sanctuary. Use Section 2- . 2-611(e) c. Provide wheelchair access to raised platforms, choir rooms, choir lofts, performing areas and other similar areas. 2-611(e) d. Assembly areas along with enclosed and unenclosed platforms and stages shall be made accessible. 2-611(e) e. Sanitary facilities shall conform to the requirements cf Chapter 2-5. 2-611(e) ASSISTIVE-LISTENING DEVICES a. Assembly areas with permanently installed public address systems (other than exclusively for paging or background music), shall' provide assistive-listening systems for people with hearing impairments. 2-611(f) b. Since the capacity of the assembly area exceeds 99, this facility requires personal receivers to be available on request. 2-611(f) c. If the system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the performing area. A sign shall be posted in a prominent place indicating the availability of assistive-listening devices. The sign shall include the international symbol of deafness and wording that states "Assistive-listening System Available". GROW B OCCUPANCY. REQUIREMENTS 30.Group B occupancies used for assemblypurposes but having an occupant load of lessthan 50 shall conform to al 1 the requirements for Group A occupancies covered in Section 2-611. 2-712(d) SALES FACILITIES a . tGeneral -sales^-a**4 office areas x»^/together with related toilet rooms must be accessible. .2-112(b) S.HOLO jf. Sales employeev work stations shall be /: located on accessible levels. Employee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible. 2-712(b) This facility requires check stands accessible to the physically handicapped, based upon 1 for 8 checkstands or less, 2 for 9 or more. 1- 712(b) Where quick check stands are provided, at least one shall be accessible. 2-712(b) Check stands shall be made accessible by providing a 36" aisle on the customer side of the stand. 2-712(b)• Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to be open at all times for handicapped/physically disabled customers". 2-712(b) FITTING OR DRESSING ROOMS a. Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the physically handicapped. 2-712(b) b. Minimum dimension of room shall be 60" x 60". 2-712(b) c. Bottom of the mirror shall be located within 20" of the floor. 2-712(b) d. Height of clothing hooks shall not be greater than 48" from the floor. 2-712(b) fto2srr»—gprovem e3 w f a occu•oo 9n«^ rt E*3•aAU f-no.>-u)kITAration s« M hcnfr i» Mn•opfH->iu »D.a IT oDU 9 nA 39 O a »3 1o nFt er srA *• U3 I\JU3 Date i x5/2^/9D Jurisdiction CARLSBAD IT Prepared byi VALUATION AND PLAN CHECK FEE n Bldg. Dept. D Esgil BUILDING ADDRESS \S?>S COVlWvA M \ d.C^ $Wcle APPLICANT/CONTACT Jen V Ol-hY;OY\ PHONE NO. 4il- 9\O6 BUILDING OCCUPANCY (V'2_ DESIGNER PHONK TYPE OF CONSTRUCTION BUILDING PORTION T T.- ^^~^^ L Air Conditioninff Commercial Residential Res. or Comm. Fire Sprinklers Total Value BUILDING AREA \tcS?5 ^ ^^/^ ^ / X '^" ^^^^/y(S - CONTRACTOR MULT»8S^ ^TC,-as" x^*^^\ Jt T / ^ ~" \ '@ :: e • • PHONE ^^ ^^-^^ VALUE t>\ P-2.O , 1^ ^_1 \ ^7 sia^o' Building Permit Fee $, Plan Check Fee $ C 0 H ME NTSj 2-97. $0 SHEET I OF ( BUILDING PLANCHECK ENGINEERING CHECKLIST $» V1 s T C H E C K § 1 1 2 N D C H E C K 3 R D C H E C K DATE: £~tiO/90 PLANCHECK NO. 90-&2.6> PROJECT ID: / 935" /Wlm<! LEGAL REQUIREMENTS Site Plan 5 \T\dfa &\blc£ ITEM COMPLETE ITEM INCOMPLETE - NEEDS YOUR ACTION X ITEM SELECTED l—i I—I i. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width and dimensioned setbacks. *—' LJ ^2. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (56) grade and drainage patterns. 3. Provide legal description and Assessors Parcel Number. Discretionary Approval Compliance 4. No Discretionary approvals were required. 5. Project complies with all Engineering Conditions of Approval for Project No. . 6. Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by: Date: Field Review 7. Field review completed. No issues raised. 8. Field Review completed. The following issues or discrepancies with the site plan were found: A. Site lacks adequate public improvements. B. Existing drainage improvements not shown or in conflict with site plan. C. Site is served by overhead power lines. D. Grading is required to access site, create pad or provide for ultimate street improvement. FRM0010.DH 08/29/89 f E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. F. Other: Dedication Requirements \s 9. No dedication required. .10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8^" x 11* plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: _____ Dedication completed, Date: By:. Improvement Requirements 1. No public improvements required. SPECIAL NOTE: Damaged or defective improvements found ad.iacent to building site must be repaired to the satisfaction of the Citv inspector prior to occupancy. .12. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit, for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to Issuance of permit. The required Improvements are: Improvement plans signed, Date: By:. FRM0010.DH 08/29/89 .13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date_ By: Grading Requirements 13a. Inadequate i nformat i on avai 1 abl e on si te pi an to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). ___L/14. No grading required as determined by the information provided on the site plan. 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: 8y: Miscellaneous Permits Right-of-Way Permit not required. .17. Right-of-Way Permit required. A separate Right-of-Way Permit Issued by the Engineering Department is required for the fol1 owlng: 18. Sewer Permit is not required. .19. Sewer Permit 1s required. A Sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. .20. Industrial Waste Permit is not required. FRM0010.DH 08/29/89 Industrial Waste Permit 1s required. Applicant must complete Industrial Waste Permit Applicantion Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted - Date: By: Fees Require^ Park-in-Lieu Fee Quadrant: Fee per Unit: .23. Traffic Impact Fee Fee Per Unit: Total Fee:, Bridge and Thoroughfare Fee Fee per Unit: Total Fee:. Public Facilities Fee required. Facilities Management Fee Zone: Permit No. Total Fee:. /I///? 25. (V/fl 26.JLP.Fee: Sewer Fees Fee: no EDU's Sewer Lateral required: Fee: frtin^tdzred oL.fl ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY: ALtd.Adt/ %%K&&£/fb%L/ Date: FRM0010.DH 08/29/89 41 0> 4* (J O O *Q ffl <B Q. a. a n PLANNING CHECKLIST Plan Check No. APN: Planner <?O-Address Phone 438-1161 (Name) Type of Project and Use ~T&w><rr Zone X 1C Facilities Management Zone Legend El Item Complete (Q) Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified Environmental Review Required: YES DATE OF COMPLETION: _____ NO TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES APPROVAL/RESO. NO. PROJECT NO. _ NO X TYPE DATE: OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval on n Coastal:YES NO DATE OF APPROVAL: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval 0n 0D Landscape Plan Required: YES NO See attached submittal requirements for landscape plans Site Plan: Q 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. [] 3. Provide legal description of property. fj 4. Provide assessor's parcel number. Zoning: PI 1. Setbacks: f/J Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown DD D / 2- Lot coverage: Required _ Shown DD D M& 3- Height: Required _ Shown 06 Dj)0 </ *' Parking: Spaces Required _ Shown _ jLj)*^ Guest Spaces Required _ Shown _ Additional comments and remarks have been made on the building plans. These marked -up plans may be picked up at the Building Department. These marked- up plans must be resubmitted with the revised plans for this project. Have plans been marked up? YES _ NO DD D Additional Comments OK TO ISSUE ^ ^ DATE PLNCK.FRM 2560 ORION WAY CARLSBAD, CA 92008 TELEPHONE (619) 931-2121 Clt? Of PLAN CHECK REPORT ADDRESS (93^T p.__/ ~+ APPROVED DISAPPROVED W* i>\ nwwpR OPAL,. ^T^SPRINKLERED } H2oRr#Tv,$Efc ?2- CONST ^TENANT IMP. /5 ' ADDRESS \Jl(t^ ADDRESS <?f\&L<>SftL> TOTAL SO. FT. SV f?-P - PHONE PHONE ^-|3 \-llQG STORIES "7A^ C> APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: 1. 2. 3. 4. 5. 6. 7. PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. Provide specifications for the following: : Permits are required for the Installation of all fire protection system^Sjrinklers^tand pipes, dry chemical, halon, COi, alarms, hydrants). Plan must be approved by the fire departmerirprTdTTolnstallatlon. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required:f\ <*> 'NiLAutomatlc 'ire sprinklers (Design Criteria: ODry Chemical, Halon, COa (Location: D Stand Pipes (Type: , \ A D Fire Alarm (Type/Location: Fire Extinguisher Requirements: rated ABC extinguisher for each extinguisher not to exceed 75 feet of travek D An extinguisher with a minimum rating of " sq. ft. or portion thereof with a travel distance to the nearest to be located: _ ; _ 0 Other: 8. Additional fire hydrant(s) shall be provided EXITS 9. Exit doors shall be openable from the Inside without the use of a key or any special knowledge or effort. 10. A sign stating, " This door to remain unlocked during business hours" shall be placed above the main exit and doors ! ; 11. EXIT signs (6" x 3A" letters) shall be placed over all required exiits and directional signs located as necessary to clearly indicate the location of exit doors, GENERAL 12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. 13. Buildlng(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or In racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. 14. Additional Requirements. . ry .15. Comply with regulations on attached sheet(s). P.an Date Report mailed to architect Met with Attach to Plans Certificate of Compliance (Port 1 012)Porlormnnco ncquiromonlr. CF-1 B Proioct Tidu Dalii ol Cwttficnlir For Cn.o,eomon, Anoncy Usn Only hitocl/EngmooT C^A^&^^L."roicct location tfuiUCng I'omiil Number Plan Chocked Uy RAY COX MECHANICAL. INC. (619) 271-7100 Documuntntinn Au^ior/Firm riilcptionn Dy Approved Dy PHnrlpnl Doslnnor. Tim propnrod building will ho in ftiihstnnlinl ctwnpluincn wild tlui Cnlilnrnia Building tnnrgy tiHtdonry Slamtiirrh piovrind it is built ncrnrrling 1o iho planr. nnd spocilimhons nnd provided tuturu improvormmlr. nro comploiod according to tho rnqiiirornnnir. indtcalnd on this Cortilicnto nt Complinnco. Tho plnns nnd spiicilicn lions hiivo boon nroparod In includu nil nignilicant onnrgy conf.orv.ttmn Itinturnr. lorjuifnd Inr compliance, with tho Stnndarch. TWkling nnini Hint nrn tincomhtionod nnd/nr not suhjor.l to Iho Mnnrlnrds iir« indiciittxl on th«i plnns. Gpocs dulou )nlu Jerry B. Pitman, Architect Jatno/J illuReal Property Services Corp. Company 1935 Gamine Vida Roble AdSor.5Carlsbad, CA 92008 CiVSialo/Zip (619) 431-9100 C-10454 Tolophonu Cal. Uconsu I4o. Owner. Tho onorny consorvalion (natures nnd pmformnnco spocilicattons indicated on this document and on tho plans nnd spoaltcaticms sh.ill apply lo Iniurn adorations, unless comptianco ir> dcmnnstratod anow and a ni-w Cortilicnto ol Compliance is suhmtllcd. A copy ol this Cf!rli(tcnlo will rws rrMnined and IransmiHwt tn lulurci tonnnls, suhsnnutsnl ownnrr, or oihurs with rosponsihility lor making improvumonls or mocMvcalions to Iho htiildmc). It this ccrlilicnlo is lor.l, a now Cmtilicnlfi may iSo required holoro a pormil is issiiod tor alteration*. Unconditional arcns arc indicated on Ihn plans,nnd. il Ihor.o nroas nro conditionod in tho tuidro. thny musl bo matk) to comply with Iho appticablo onorgy standards tt/cn fn oljuct.ttlcn/fn olILL _^_ Allan S. Bird, President Naiiio/Tillu Real Property Services Corp IVCamino Vida Roble CarTsbad, CA 92008 CTty/Olale/7ip Enlorcemunt Afjcnry. Tho propor.od building, nnd (utviro atlnr.ilions will comply with iho Cnlilnrnia lluilding t-norgy Hllioioncy iitnndar<h. provickid Kinrrii n I iu rations nu-*)i iho rnqiiifumnnlr; imbcnlod on tins Cortilicato and oil nppticahlo mnndatnrv monsurns. as long as tho building occupancy typo rcmnins'unchanged. Afjoncy Aouross City/StaKi/Zip * Compliance documents to be provided by electrical designer flY Anilyil. Ihn nnorgy porinrmnnrn analystr. sumninn/pd hotnw porloriTKirt lining an npiwovoil CI-X cnlculniinn ini'ihrwl. wiih CIO npprtwod lixod nnd rtrttnctncl (-nninonnrw) inpiili lor iho upptir.ibli! clim.ili1 lono nnd occupancy typii. and using »n appropnnti! M'pritSdntalion ol htiilding zoning nnd physlc.nl conliguration. Alt sigmlic.ini onorgyconsorvation loiituo-r. nio lislotl bolow. or on an nltiichrtd supplomeni im,L HAMPSON/VTCr: PRESIDENT MECHANICAL, INC. Company ipfas SCRIPPS RANCH BLVD., SUITEJL Acldross". SAN DirGO, CA 92131 '(l\9\ 271-7100 Tolophbno General Rol 1 Unconditionod or Multi-tonant shell 2 CHC Occupancy Type . . . . _l 3 Unc Occ. Group/Division . . . I» Conditionod Floor Arna . , . .__ fi UnnnnHilionHd Ploor Aron . . , cronco i ». . . N k* UPC3a- 2 ~7 -©- . r,l 7 nurigcl Tahtn (If. Slandnrd^;) . fife£-P 2.~5^P^ n All rnnrnvnndnnt(Wr.-1A) .QUTftJT , SoM Kniu/r.t-yi 0 Cnlc.MothodCrCCodo/DaloUlS-lA I4<2> 11 Cnlculatod Enorgy Use . . . Envelope Requirement* 1 2 Avorago Rool/Coiling R| . , . £ 13 Avorago Exlorior Floor f\\ . , . 14 Avnrago Opnquo Walt RI . . . 15 Glazing Aroa In Wall 1 G Avorngo SC (Wall glaring) . . 17 Glaring Aron In Roof t1 10 Avorago SC (Root glazing) . . _j Lighting Requirement! 19 Allowed Whoto Ouilding IPD . 20 Allnwod Common Areas LPD . |.<3 ^1,1 kniii/st-yr f~1 \*\>Zo h-F-simm j & h-F-Rlffltu N»A h-F-sWliu fcA »» hlA J£L_ -kl^ *'\ HA * |_*5 wnlir./sl * * walts/sl 21 Allowed Tonam Space LPD . ., ^_ * wntis'sl 22 Packnoo Lighlino Roduction * * . wnttn/sl 2,1 Llnhlinn Controls norwircd? . . * * (Y/N)-~^ Meohanlcol netiulrementa ?<t Sy«ttnm Typn .,.-.. ^£LtT SY&TCM ' TO Ralod Coolinn EHictonrv . . . 27 flatod Coolinrj Capacity . . . 20 n.itod Moating Ellicioncy ... 20 Ratrxt Homing Capacity . . . 30 Economizer cooling? . . . . ^t 31 CF-lXAttKhncP T^PiJT «4-4 wnnsydm^F)'' q.2. e.ee. 1,,™*) 3^»00 BlUHrtffiinilr.) 3 * 1 ^ C^?P^ limif.l /i ^ ^_ ^. _. fftttl/r*tr _ .jfpjfflOO PjuiYpjftmitsl J Kl (Y/MJ. _ . . M (Y/M) TfM Fivm nrvr.M Snplr-mhor 1900 Pngr.ol BUIL DING PERMIT 08/14/90 15:27 CAMINO VIDA ROBLE Permit Type: PLAN CHECK REVISION Parcel No: 212-092-18-00 Valuation: ° Construction Type: VI 7 WINDOWS IN ONE HR CORR Str: PCR No: PCR90088 Project No: A88tfOl84 Development No: _/, Fl: Ste: Ofc-ft °V'7</<j 7413 08/14/90 0001 01 02 t-PRMT 1U Status: ISSUED Applied: 08/13/90 Apr/Issue: 08/14/90 Validated By: DC ** Fees Required ******Fees Collected & Credits *** Fees: Adjustments: Total Fees: 118.00 Fee description Plan Check Revisio ***<*'*« <?*' *^*^>^*"wr- ;v ?«*,"v?*Si?<*'*»-••& .'•„»*^/.-?o; ^ i^V Vj*•%Vf^*,v y>if *? *}^s&$v* .00 .00 118.00 Ext fee Data 118.00 INSP. CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (eis) 438 HE,i 1. .PERMIT TYPE_ . A - BKOMMERCIAL QNEWM^ENANTIMPROVEMENT B - Ll INDUSTRIAL QNEU QTENANT IMPROVEMENT c - PRESIDENTIAL OAPARTMENT QCOMDO QSINGLE FAMILY DWELLING QADDITJON/ALTERATION QDUPLEX QDEMOLITION QRELOCATION QHOBILE HOME QELECTRICAL DPOOL QSPA DRETAIMJW; wu PROJECT INFORMATION FOR OFFICE USEONLY EST. VAL PLAN CK DEPOSIT, VALID. BY DATE LEGAL DESCRIPTION CHEOTKLOU IF SUBMITTED: D2 Energy Calcs D2 Structurat calcs D2 Soils Report Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE DESCRIPTION 3. CONTACT PERSON 4. APPL NAME CITY Q AGENT FOR CONTRACTOR QOWNER ADDRESS STATE ZIP COOf QAGENT FOR OWNER DAY TELEPHONE OWNER CITY 6. CONTRACTOR NAME CITY STATEC_-« ffj~2 STATE fL) ZIP CODE / ^C/5 ADDRESS ZIP CODE J ft D*Y TELEPHONE DAY TELEPHONE STATE L1C. #LICENSE CLASS CITY BUSINESS LIC. # SIGNATURE DESIGNER NAME CITY 7. WORKERS'COMPENSATION TITLE ADDRESS STATE ZIP CODE DATE DAY TELEPHONE STATE LIC. * Compensation Declaration: I hereby affirm that I have a certificate of consent to selfMnsure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO.EXPIRATION DATE Certificate of Exemption: I certify that in the performance of the work for uhich this permit is issued, i shall not employ any person in any mannerso as to become subject to the Workers' Compensation Laws of California. 8. OWNER-BUILDER DECLARATIONOwner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, ami who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I an exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars t$500]). COMPLETE THIS SECTION FOR NQH- RESIDENTIAL la the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections ZS505, S5533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Is the applicant or future building occupant requfrecPto obtain a permit from the air pollution control district or air quality management district? DYES /Si*0 Is the facility to be constructed within 1,000 feetoTthe outer boundary of a school site? OYES J35° IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1999 UNLESS THE APPLICANT HAS NET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 9. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the perf°rmance of the work for which this permit is issued (Sec 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE T certify that I"have read the application and state"that the above information is correct.I agree to complylnth all City ordinances and State laws relating to building construction. 1 hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGNtNST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). . APpN CANT'\lw Q OWNER QCOHTRACTOR APPROVED ST.- DATE! „ WHITE: File YELLOW: Applicant PINK: Finance