HomeMy WebLinkAbout1935 CAMINO VIDA ROBLE; ; PC050037; Permit3City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-29-2005 Plan Check Permit No: PC050037
Building Inspection Request Line (760) 602-2725
Job Address 1935 CAMINO VIDA ROBLE CBAD
Permit Type PLANCK Status PENDING
Parcel No 2120921800 Lot* 0 Applied 03/23/2005
Valuation $000 Construction Type Entered By RMA
Reference # Plan Approved
Issued
Project Title 3 SPEC SUITES.STE 100=7359 SF. Inspect Area
STE 1 10=8749 SF & STE 200=12771 SF TOTAL(IMPROVE
Applicant Owner
RICK LIEN 1935 CAMINO VIDA ASSOCIATES L L C
CIO DOUG MCCORMICK
1 65 S UNION BLVD #510
LAKEWOOD CO 80228
619 339-7425
Plan Check Fee $0 00
Additional Fees $0 00
Total Fees $000 Total Payments To Date $000 Balance Due: $0.00
BUfLDING PLANS
-*- IN STORAGE i-
-ATTACHED
FINAL APPROVAL
Inspector Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth m Government Code Section 66020(a), and file the protest and any other required information with the City Manager far
processing In accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which VQJ hava previously been given a NOTICE similar to this, or as to which the statute of limitations has orevtouslv ottienvise exoired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
1 ,. PROJECT INFORMATION
FOR OFFICE USE ONLY
PLAN CHECK NO /£) C^> f £?/P ? 7
EST VAL (/_
Plan Ck Deposit
Validated By
Date
Address (include Bldg/Suite #)
S?^U£?^*k^>u
Business Name (at this address)
Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor's Parcel #Existing Use proposed Use
of Bildrdoms V # of 'BSthraornsDescription of Work SQ FT
Orf-iCi> TOOf^fiCg
2 CONTACT PERSON (if different from applicant) ,
#of Stories
Name Address City
3 . APPLICANT . C] Contractor' Q'Agent for Contractor D 'Owner Q Agent for Owner
State/Zip Telephone # Fax i
NSme Address City State/Zip Telephone #
PROPERTY OWNE
Address City State/Zip Telephone #Name
5- CONTRACTOR - COMPANY NAME ', .. j ,
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
^ny wolation of Section 7031 5 by any applicant for a permit subjects the applicant to a ciyil penalty of not mjjve, than five hundred dollars l$500|)
Name Address
State License # License Class
City State/Zip Telephone #
City Business License # / gf~t£. f go
Designer Name Address City State/Zip Telephone
State License #
6 .WORKERS' COMPENSATION
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
[~l I have and will maintain workers compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker s compensation insurance carrier and policy number are
Insurance Company S~f75~72S /^/Uft Policy No /' ?JS _2?<£- *2- Expiration Date //"<?/ ~ &£
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
C] CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers Compensation Laws of California
WARNING Failure tosejZure workers cpfnpensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($10j£rOO&) ^additiop^dfthe cost of compensation, damages as provided for in Section 3706 of the Labor ootie, mteres^and attorney s fees
SIGNATURE /^-^^L (T~*~*~ DATE
7 OWNER-BUILDER DECLARATION : ' .
I hereby affirm that I am exempt from the Contractor's License Law for the following reason
PI I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees provided that such improvements are not intended or offered for sale If, however the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
f~l I, as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor s License Law)
l~l I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement O YES DNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE DATE
^COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY , ,•* ;,
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act' f~l YES l~l NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES CD NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site' fj YES Q NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
8. CONSTRUCTION LENDING AGENCY ; •» > "
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit \s issued (Sec 3097(i) Civil Code)
LENDER'S NAME LENDER'S ADDRESS
i9 APPLICANT'CERTIFICATION L '„.:.-. ~,•,,.';,'..- , , ,: ,
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
.^ at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code)
V\APPLICANT s SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
EsGli Corporation
In Partnership untR government for QvikRng Safety
DATE- 5/11/05 a APP1
Q<
JURISDICTION City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO PC05-OO37 SET III
PROJECT ADDRESS. 1935 Camino Vida Roble
PROJECT NAME Spec Suites 100, 110 and 20O - TI
I I The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
IXI The applicant's copy of the check list has been sent to:
Rick Lien
P.O. Box 930, Poway, CA 92074
I I Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Rick Lien Telephone #• 619-339-7425
Date contacted «S/)//o5(by:(c~. ) Fax #:
Mail Telephone"•" Fax In Person-^
REMARKS-
By Doug Moody Enclosures:
Esgil Corporation
D GA Q MB D EJ D PC 5/4/05 tmsmUdot
9320 Chesapeake Dnve, Suite 208 * San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
City of Carlsbad PCO5-OO37
5/11/OS
RECHECK PLAN CORRECTION LIST
JURISDICTION: City of Carlsbad PLAN CHECK NO.' PC05-0037
PROJECT ADDRESS 1935 Camino Vida Roble SET' III
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED
ESGIL CORPORATION- 5/4/05 5/11/05
REVIEWED BY Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A Please make all corrections on the original tracings and submit three new complete sets of
prints to ESGIL CORPORATION
B. To facilitate rechecking, please Identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C. The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
QYes QNo
City of Carlsbad PC05-OO37
5/11/05
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1, Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE. Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
These corrections are in response to Items not fully addressed or as the
result of information provided, the text in bold underlined print indicates
the unresolved issue.
8 Please revise the plans to show the panel locations for the individual suites
demonstrating compliance with section 240-24 of the1999 NEC. Please indicate
on the plans the Individual tenant suites. Indicate how the tenants in
space109 will have access to the over-current devices In space 129?
10. Show on the site plan the complying disabled accessible path of travel from the
disabled accessible parking spaces to the primary entrance of the tenant space
Please provide detailed plans of the path of travel, indicate slope and width, any
pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking
stall details etc. Please provide fully dimensioned plans for the new
exterior path of travel.
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you.
EsGii Corporation
In fartntnKip iwtfi government for <Kv.*Gfing Softly
DATE 4/26/O5 G APPLICANT
f D JJJRJSI>
JURISDICTION City of Carlsbad TTPLAN REVIEWER
a FILE
PLAN CHECK NO PCO5-0037 SET II
PROJECT ADDRESS 1935 Camino Vida Roble
PROJECT NAME Spec Suites 1OO, 110 and 20O - TI
[~1 The plans transmitted herewith have been corrected where necessary and substantially comply
with the junsdiction's building codes
f~] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies Identified below are resolved and checked by building department staff
[~~| The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation unti) corrected plans are submitted for recheck.
f~1 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Rick Lien
P.O. Box 930, Poway, CA 92074
LJ Esgi! Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person jpojitacted' Ricl^Lten (^J Telephone # 619-339-7425
Fax #•
Mail -"""felephone -^ Fax In Person
REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 4/18/05 tmsmtldot
9320 Chesapeake Dnve, Suite 208 4 San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576
City of Carlsbad PCOS-O037
4/26/05
RECHECK PLAN CORRECTION LIST
JURISDICTION. City of Carlsbad PLAN CHECK NO/ PC05-O037
PROJECT ADDRESS: 1935 Camino Vida Roble SET: II
DATE PLAN RECEIVED BY DATE RECHECK COMPLETED
ESGIL CORPORATION: 4/18/05 4/26/O5
REVIEWED BY: Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec. 106.4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A Please make all corrections on the original tracings and submit three new complete sets of
prints to ESGIL CORPORATION
B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C The following items have not been resolved from the previous plan reviews The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items
D Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
Q Yes a No
City of Carlsbad PCO5-OO37
4/26/05
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineenng and Fire Departments.
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE. Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
These corrections are in response to items not fully addressed or as the
result of information provided, the text in bold print indicates the
unresolved issue.
4 In buildings having floors and roofs of wood frame construction, other than
dwelling or hotel occupancies, draft stop the area between the ceiling and floor
above so that no concealed space exceeds 1,000 s f and no horizontal
dimension exceeds 60 L F (if space has sprinklers, then 3,000 s f and 100
L F ) Section 708 Please revise the detail for the draft stop to show the
attachment to the structure and lateral bracing ( most of the draft stops are
not supported by partition walls below).
5 Please revise the plans to show the location of the stairs from the second floor?
Where does the second floor stair exit the building on the first floor for
stair 238?
8 Please revise the plans to show the panel locations for the individual suites
demonstrating compliance with section 240-24 of the1999 NEC Please indicate
on the plans the individual tenant suites. Indicate how the tenants in
space109 will have access to the over-current devices in space 129?
10 Show on the site plan the complying disabled accessible path of travel from the
disabled accessible parking spaces to the primary entrance of the tenant space
Please provide detailed plans of the path of travel, indicate slope and width, any
pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking
stall details etc. Please provide fully dimensioned plans for the new
exterior path of travel
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
City of Carlsbad PCO5-0037
4/26/O5
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation. Thank you
EsGii Corporation
In fartnenfap vnth government for Quitting Safety
DATE: 4/6/05 a APPLICANT
JURISDICTION City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: PCOS-0037 SET I
PROJECT ADDRESS- 1935 Camino Vida Roble
PROJECT NAME Spec Suites 100, 110 and 20O - TI
I I The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I [ The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to:
Rick Lien
P.O. Box 930, Poway, CA 92074
[~~] Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Persorvcontacted' Rick Lien CV^y Telephone #: 619-339-7425
Date cMa^lcr Lt u£% (by (& ) Fax #
Mail ^^xTelephone•>-^ Fax In Person
REMARKS
By Doug Moody Enclosures1
Esgil Corporation
D GA D MB D EJ D PC 3/24/05 tmsmUdot
9320 Chesapeake Dnve, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576
City of Carlsbad
4/6/05
PCO5-OO37
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: PCOS-OO37
OCCUPANCY B
TYPE OF CONSTRUCTION: IIIN
ALLOWABLE FLOOR AREA
SPRINKLERS? YES
REMARKS-
DATE PLANS RECEIVED BY
JURISDICTION 3/23/05
DATE INITIAL PLAN REVIEW
COMPLETED: 4/6/05
JURISDICTION- City of Carlsbad
USE: Office
ACTUAL AREA' 26158sf
STORIES: 2
HEIGHT:
OCCUPANT LOAD. 298
DATE PLANS RECEIVED BY
ESGIL CORPORATION. 3/24/05
PLAN REVIEWER Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforwdot
City of Carlsbad PC05-0037
4/6/O5
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industnal projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and tne Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE' Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. Plans and calculations shall be signed by the California state licensed engineer
or architect where there are structural changes to existing buildings or structural
additions. Please include the California license number, seal, date of license
expiration and date plans are signed Business and Professions Code
2 Provide a fully dimensioned floor plan showing the size and use of all rooms or
areas within the space being improved or altered Draw the plans to scale and
indicate the scale on the plan. Section 106.3.3
3. Show any existing fire rated corridors. Identify and provide construction details
for proposed new fire rated walls and methods of integrating existing walls .
4 In buildings having floors and roofs of wood frame construction, other than
dwelling or hotel occupancies, draft stop the area between the ceiling and floor
above so that no concealed space exceeds 1,000 s f and no horizontal
dimension exceeds 60 LF. (if space has sprinklers, then 3,000 s f and 100
L F ) Section 708.
5. Please revise the plans to show the location of the stairs from the second floor?
6 Pease revise the plans to show the doors to room 236 to comply with the
following Corridors shall have interior door openings protected by tight-fitting
smoke and draft control assemblies rated 20 minutes Doors shall be
maintained self-closing or be automatic closing by action of a smoke detector per
Section 713 2 Doors shall be gasketed to provide a smoke and draft seal where
the door meets the stop on sides and top Section 1004 3.4 3 2.1.
7 Please note on the plans "AC Cable is not allowed in A, B, E, H, and I
occupancies NM cable is restricted (without City approval) to one and two
City of Carlsbad PC05-0037
4/6/05
family dwellings Note on plans that an equipment ground conductor is to be
installed in all flexible conduits"
8 Please revise the plans to show the panel locations for the individual suites
demonstrating compliance with section 240-24 of the1999 NEC.
9. When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B 2. These
requirements apply as follows.
a) A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features
10. Show on the site plan the complying disabled accessible path of travel from the
disabled accessible parking spaces to the primary entrance of the tenant space.
Please provide detailed plans of the path of travel, indicate slope and width, any
pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking
stall details etc.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e., plan sheet, note or detail number,
calculation page, etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate.
Yes Q No Q
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation Thank you
City of Carlsbad PC05-OO37
4/6/05
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad PLAN CHECK NO.: PC05-0037
PREPARED BY: Doug Moody DATE: 4/6/05
BUILDING ADDRESS. 1935 Camino Vida Roble
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION: IIIN
BUILDING
PORTION
Tl
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
26158
cb
Valuation
Multiplier
3000
^
By Ordinance
Reg
Mod
VALUE ($)
784.740
784,740
1994 UBC Building Permit Fee •*
1994 UBC Plan Check Fee
Type of Review
D Repetitive Fee~^\ Repeats
Complete Review
D Other
-i Hourly
G Structural Only
Hour1
Esgll Plan Review Fee
$2,522^41]
$1,639.57
$1,412.55
Comments.
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER
ADDRESS
DATE
RESIDENTIAL
RESIDENTIAL ADDITION MINOR.
« $10.000.00)
TENANT IMPROVEMENT
CARtSBAD COMPANY
VILLAGE FAIRE
COMPLETE OFFICE-BUILDIIMC
OTHER
PLANNER DATE
ENCINEE DATE
I i I
i- JB- *sec
I I I
I I I
UD
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. Of r^tf* ~ J^
Planner Mitel cYfrVnj
APN' Z./ 2-^)^72. IS
Type of Project & Use: "J~j
Zoning: f 'M General Plan: f/
CFD (In/out) # Date of participation:
Address /1J> 5 t^W
Phone (760) 602- <^2--
, Net Project Density: fiJ/A
Facilities Management Zone: £
Remaininq net dev acres:
lV(S(tWLWAf>K
S~
j~« \f^r.
Circle Ona (For non-residential development: Type of land used created by this
permit )
LeoendL, S Item Complete Q Item Incomplete - Needs your action
Environmental Review Required: YES NO /f TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval: ,
Discretionary Action Required:
APPROVAL/PESO. NO.
PROJECT NO.
YES _ NO
_ DATE
TYPE.
OTHER RELATED CASES: _
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES NO V
CA Coastal Commission Authority? YES NO A
If California Coastal Commission Authority: Contact'tHem at - 7575 Metropolitan Drive, Suite 103,
San Diego CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Font) already completed? YES.
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
NO_
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
Incluslonary Housing Fee required: YES NO X
(Effective date of Inclusionary Housing Ordinance • May 21,1993.)
Data Entry Completed? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATEI)
Site Plan:
H \ADMINVCOUNTER\BldgPtnchkRcvChMtt
D D 1- Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-way
width, dimensional setbacks and existing topographical lines (including all side and rear yard
slopes).
OD 2- Provide legal description of property and assessor's parcel number.
ODD
ana
ana
ODD
Policy 44 - Neighborhood Architectural Design Guidelines
1. Applicability: YES _ NO _
2. Project complies YES NO
Interior Side:
redtSIde:
lean
Structure>eparation:
Required
Required ,,,., .
Required
Required
Required .,_
jre setbacks:
Required,
Required ,
Required ,_ ,.
Required
ion: Required
Required ,
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Required.Shown.
Spaces Required,Shown.
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments
# 0+ far tin*
'i •'. ••'"•! *•w/d. also
OK-TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H:\ADMINVCOUNTEFWW8PlnchkRwChkht
STUDIO WEST
INTERIORS
April 14, 2005
City of Carlsbad
Planning Department
1635 Faraday Avenue
Carlsbad, Ca 92008
Re: 1935 Camino Vida Roble
Responses to corrections
1 Number of parking spaces and breakdown of spaces is now shown on the site plan
2 There are no new proposed units being added to the roof
4425 UPLAND STREET
LA MESA CA 91941
619 465 5118
FAX 303 5118
Carlsbad Fire Department 050037
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review
Date of Report
Requirements Category:
03/24/2005
Building Plan
Reviewed by qw**i
Fire Prevention
(760) 602-4660
Name:
Address*
City, State
Rick Lien
P O Box 930
Poway CA 92074
Plan Checker
Job Name
Job Address.
P5i Approved
Job # 050037
Spec Suites
1935CaminoVidaRoble
Bldg # PC050037
Ste or Bldg No
The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
D Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
isi 2nd 3rd
050037 FDFile*
Other Agency ID
p. 1
c?M*ib - '
I"l
Lx..*
MA|U££
e fcr) -.
R £><=•
\I
'
* «-
•TILT-
I'
U/J6.
P.
STRUCTURAL NOTES;
GENERAL:
1. The contractor shall verify all dimensions before starting work, and the owner
notified immediately of any discrepancies found.
2. In case of conflict, notes and details on the drawings take precedence over this
sheet
3. Character of the soil is IM/ft . Design allowable soil
bearing pressure is _•• • psf.
4. Where no construction details are shown or noted for any part of the work,
the details shall be the same as for other similar work.
5. Construction shall be in conformance with the requirements of the California
Building Code, 2001 edition.
6. Should any loose fill, expansive soil, ground water, or other adverse conditions
be encountered during excavation, the owner shall be notified and all work
stopped immediately.
7. Neither the owner or the engineer of work will enforce safety measures or regulations,
the contractor shall design, construct, and maintain all safety devices, including
shoring, and shall be solely responsible for conforming to all local, state, and
federal safety and health standards, laws, and regulations, and shall indemnify
the owner and engineer of all responsibilities.
STRUCTURAL STEEL:
1. Structural steel rolled shapes, plates, and bars shall be per ASTM A36 or
ASTM A992. Steel pipe used for structural purposes shall have physical properties
conforming to ASTM A3 6.
2. Welding to be shielded metal arc method using E70xx electrodes. Field welding to be
continuously inspected by a registered deputy inspector. Welding technique, work-
manship, and inspection shall conform to: AWS Dl .0, "Code for Arc and Gas
Welding in Building Construction".
3. Square and rectangular structural tubing (HSS) shall be per ASTM A500 Grade B.
4. Unless noted otherwise, materials and workmanship shall conform to the latest
edition of. "AISC Specifications for the Design, Fabrication, and Erection of
Structural Steel for Buildings".
5. Machine bolts and anchor bolts shall conform to AISC A307, Grade A. High-
strength (HS) bolts shall conform to ASTM A325; field inspection required for
installation.
6. Unless otherwise shown, bolts to be %" diameter, 1 Vi" minimum edge distance,
and 3" minimum spacing.
7. Welds identified as requiring continuous or periodic inspection need not have
special inspection when the welding is done in an approved fabricator's shop.
However, the approved fabricator must submit a Certificate of Compliance in
accordance with CBC sections 1701 5.5 and 2231 A,
ytMft\O{ (6) \/4(00OV^»
so
COMPENSATION
INSURANCE
POLICYHOLDER COPY
PO BOX 807, SAN FRANCISCO.CA 94142-0807
FUND
ISSUE DATE
CERTIFICATE OF WORKERS' COMPENSATION INSURANCE
11-O1-2OO4
CITY OF SAN DIEGO
ATTN BLOG DEPT
1222 FIRST AVE MS301
SAN DIEGO CA 92101-4153
SO
GROUP-
POLICY NUMBER. 121S362-2004
CERTIFICATE ID- 180
CERTIFICATE EXPIRES- 11-01-2006
11-01-2004/11-01-2008
JOB: ALL OPERATIONS
This is to certify that w0 have issued a valid Workers' Compensation insurance policy in a form approved by the
California Insurance Commissioner to the employer named below for the policy period indicated.
This policy is not subiect to cancellation by the Fund except upon 30 days' advance written notice to the employer
We will also give you 30 days' advance notice should tins policy be cancelled prior to its normal expiration.
This certificate of insurance is not an insurance policy and does not amend, extend or alter the coverage afforded
by the policies listed herein. Notwithstanding any requirement term, or condition of any contract or other documentwith respect to which this certificate of insurance may be issued or may pertain, the insurance afforded by the
policies described herein Is subject to all the terms, exclusions and conditions of such policies
AUTHORIZED REPRESENTATIVE PRESIDENT
EMPLOYER'S LIABILITY LIMIT INCLUDING DEFENSE COSTS: $1,000,000.00 PER OCCURRENCE.
ENDORSEMENT 4206B ENTITLED CERTIFICATE HOLDERS' NOTICE EFFECTIVE 11-01-2004 IS ATTACHED TO AND
POfWS A PART OP THIS POLICY.
EMPLOYER LEGAL NAME
PREVOST CONSTRUCTION,
339 N HIGHWAY 101
SOLANA BEACH CA 92075
INC PREVOST CONSTRUCTION AND/OR
SOLANA BEACH BUILDERS, INC
10/IS/2004