HomeMy WebLinkAbout1940 CAMINO VIDA ROBLE; ; CB013709; Permit01-29-2002
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB013709
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
Applicant:
LEIN RICK
PO BOX 930
POWAY CA 92074
619-339-7425
1940 CAMINO VIDA ROBLE CBAD
Tl Sub Type:
Lot#:
$12,000.00 Construction Type:
Reference #:
MV TECHNICAL SALES
INSTALL RACK SYSTEM
COMM
0
NEW
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
11/30/2001
JM
12/28/2001
01/29/2002
01/29/02 0002 01
CGP
02
117.61
Total Fees: $192.42 Total Payments To Date: $74.81 Balance Due: $117.61
Building Permit
• Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add1! Pot. Water Con. Fee
Reel. Water Con. Fee
$115.09
$0.00
$74.81
$0.00
$0.00
$2.52
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
Meter Size
Add'l Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF
PFF (CFD Fund)
License Tax
License Tax (CFD Fund)
Traffic Impact Fee
Traffic Impact (CFD Fund)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$192.42
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes trie Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expjrej,
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO
EST. VAL.
Plan Ck. Deposit
Validated
Date
{(. * ?>'
i/
Address (include Bldg/Suite #1 Business Name (at this address)
Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units
- I
Assessor's Parcel #Existing Use Proposed Use
5639 11/30/01 OP02 01 03
of Bedrooms COP* Bathrooms -r* n«Description of Work
2*
SQ. FT.#of Stones
Name Address
Name
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to ajpivil penajty of not more than five hundred dollars [S500J).c>
Name
State License ft ft3^
Address
SO / O License Class C- L—
City
."•MaaBS^iSSS^MCitUfBMHHH
State/Zip Telephone #
Designer Name
State License #
Address City State/Zip Telephone
Workers' CompensationDeclaration: I hereby affirm under penalty of perjury one of the following declarations:
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
0. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
n CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: FaiKire to secure workon' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
($TgO,090}, In adpmop to the cost of compensation, damages as provided for in Section 3706 of the Labor cods', interest and attorney's fees.
. . i . "DATE C '
NATION
hereby affirm that I am exempt from the Contractor's License Law for the following reason:
n I- as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
n I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):
6. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the bajlding Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not copffne<[ceirjwithin 180 days/pem the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is comy$pQe<fty/j} period of Igjxlavs (Section 106,4.4 Uniform Building Code). / /
APPLICANT'S SIGNATURE /A^f.f/V<~ r^£JU<- ^ DATE ///3£>/& /
WHITE; File YELLOW: Applicant PINK: Finance 7
City of Carlsbad Bldg Inspection Request
For-. 11/20/2002
Permit* CB013709
Title: MV TECHNICAL SALES
Description: INSTALL RACK SYSTEM
Inspector Assignment: TP
1940 CAMINO VIDA ROBLE
Lot 0
Type: Tl
Job Address:
Suite:
Location:
APPLICANT LEIN RICK
Owner: TECHPLEX NO 2 L P
Remarks: AM PLEASE
Sub Type: COMM
Phone: 6197085195
Inspector:
Total Time:Requested By: WOODY THORPE
Entered By: KAREN
CD Description
19 Final Structural
Act Comments
Associated PCRs/CVs
PCR01135 ISSUED MV TECHNICAL/ UNDERGROUND; PLUMBING LINES, STUB OUT FOR FUTURE TI
PCR01184 ISSUED MV TECHNICAL-DEFERRED ROOF &; FLOOR SYSTEM
Insection History
Insp Comments
TP CONT. WORKING ON CORR. EXTND PERMIT
TP NEED FIRE FINAL PRIOR TO BLDG
Date Description
08/13/2002 19 Final Structural
08/01/2002 19 Final Structural
07/31/2002 19 Final Structural
02/04/2002 19 Final Structural
02/04/2002 29 Final Plumbing
02/04/2002 39 Final Electrical
02/04/2002 49 Final Mechanical
Act
CO
NR
CO
NR
WC
WC
WC
TP
TP
TP
TP
TP
RACKS INSTALLED W/O INSP, CONT NOTIFIED
BLSG LOCKED
EsGil Corporation
In fartnersfiip witfc government for Qui&ing Safety
DATE: 12/24/01
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 01-3709 SET: II
PROJECT ADDRESS: 1940 Camino Vida Roble
PROJECT NAME: Storage Racks for MV Technical
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: .o Telephone #:
Date contacted: (by: llJyy\*£L-~— Eax #:
Mail TeleDtjone^^ Fax InFerson
REMARK^jl/City to field verify that the path of travel from the handicapped parking space to
the rack area and the bathrooms serving the rack area comply with all the current disabled
access requirements. 2 Fire Department approval is required.
By: David Yao Enclosures:
Esgil Corporation
GA D MB ID EJ D PC log trnsmtl.dot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576
EsGii Corporation
In Partners/lip with government for Sui&ing Safety
DATE: 12/12/01 a APfiUCANT
JURISDICTION: Carlsbad Q FUANREVIEWER
a FILE
PLAN CHECK NO.: 01-3709 SET: I
PROJECT ADDRESS: 1940 Camino Vida Roble
PROJECT NAME: Storage Racks for MV Technical
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted fora complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Rick Lien P O Box 930, Poway, CA 92074
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Rick Lien (^. H ) Telephone #: (619)339-7425
Date contacted: * 2.1 id>)o, (by: ^_ ) Fax #: (858)486-5081
Mail *-" Telephone ^~ Fax In Person
REMARKS:
By: David Yao Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 12/3 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576
Carlsbad 01-3709
12/12/01
1. Only the storage racks are included in this plan review
2. Provide a statement on the Title Sheet of the plans that this project shall comply with
Title 24.
3. Provide a note on the plans indicating if any hazardous materials will be stored and/or
used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E.
4. City to field verify that the path of travel from the handicapped parking space to the rack
area and the bathrooms serving the rack area comply with all the current disabled
access requriements. Title 24, Part 2.
5. Obtain Fire Department approval for groups F, M and S occupancy storage per UBC
Sections 306.8, 309.8 and 311.8.
6. Indicate the clearance from the new racks to the existing building walls and building
columns.
7. Provide forklift protection per Section 2222.5(or check the exception).
Recheck the "pallet" racks as follows:
8. Recheck all connections on sheet 1 as follows:
a) The rivet bearing capacity is only dtFu = 0.406(0.0747)65 = 2 kips.
b) Provide calculations for all beam to bracket weld capacities per Section 2330
(allowable weld stress is the member thickness times 26 ksi times 1.33, or the
weld stress, whichever is lower).
c) Check the bracket maximum weak axis moment.
9. Indicate the safety pin size and verify it is adequate for the 1000# load.
10. Recheck the base plate anchors as follows:
a) Check the transverse seismic for overturning with only the top shelf loaded with
the force acting through the center of gravity of the top load.
11. Provide calculations for the column weak axis bending plus axial for transverse seismic
loading. The axial load is the maximum compression load at the base from vertical plus
seismic overturning. The column moment will probably be maximum for the lateral load
from the base plate to the first diagonal brace (not only to the first horizontal member).
12. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact David Yao at Esgil Corporation. Thank you.
Carlsbad O1-37O9
12/12/01
GENERAL PLAN CORRECTION LIST
JURISDICTION: Carlsbad PLAN CHECK NO.: 01-37O9
PROJECT ADDRESS: 1940 Camino Vida Roble
DATE PLAN RECEIVED BY DATE REVIEW COMPLETED:
ESGIL CORPORATION: 12/3 12/12/01
REVIEWED BY: David Yao
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
• Please make all corrections on the original tracings, as requested in the correction list. Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects).
For expeditious processing, corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will
route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire
Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining
sets of plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete. To facilitate rechecking, please identify, next to each item, the sheet of the
plans upon which each correction on this sheet has been made and return this sheet
with the revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
Q Yes a No
Carlsbad 01-3709
12/12/01
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 01-3709
PREPARED BY: David Yao DATE: 12/12/01
BUILDING ADDRESS: 1940 Camino Vida Roble
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
BUILDING
PORTION
storage racks
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
cb
Valuation
Multiplier
By Ordinance
Reg.
Mod.
per city
VALUE ($)
12,000
12,000
$115.09
Plan Check Fee by Ordinance
Type of Review:
Repetitive Fee
Repeats
Complete Review
D Other
I-, Hourly
Structural Only
Hour*
Esgil Plan Review Fee
$74.81
$64.45
Comments:
Sheet 1 of 1
macvatue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS
DATE
'€L
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER
ENGINEER
DocsMlsforms/Ptannlng engineering Approvals
Car&bad Fire Department 013709
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category: Building Plan
Date of Report: 01/24/2002 Reviewed by:
Fire Prevention
(760) 602-4660
Name:
Address:
City, State:
Daryl K. James
205 Colina Terrace
Vista CA 92008
Plan Checker:
Job Name:
Job Address:
MV Technical Sales
Job#: 013709
Bldg #:
1940 Camino Vida Roble Ste. or Bldg. No.
r—I Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
D Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review
FD Job #
1st 9nH 3rd
013709 FDFiie*
Other Agency ID
Address: 205 Colina Terrace
City, State: Vista CA 92008
Carlsbad Fire Department 013709
/teafraradayAve. Fire Prevention
Carlsbad, CA 92008 (760) 6lfi&0
Plan Review / *
Date of Report: 01/24/2002 Reviewed by:
Name: Daryl K. James
Plan Checker. £1E£?
Job Name: MV Technical Sales
Job Address: 1940 Camino Vida Roble Ste. orBldg. No.
Approval of these plans is as submitted. Any chnages or deviations from those submitted to this
office for approval constitutes a violation of this approval, and shall result in revocation of our
approval.
Fire Department 013709
1635 Faraday Ave.
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report: 12/11/2001
Building Plan
Reviewed by:
Fire Prevention
(760) 602-4660
0-
Name:
Address:
Rick Lien
P O Box 930
City, State: P°way CA 92074
Plan Checker:
Job Name: MV Technical Sales
Job#: 013709
Job Address: 1940 Camino Vida Roble
Bldg #: CB013709
Ste. or Bldg. No.
I I Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
0 Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review
FD Job #
1 st ?nd 3rri
013709 FDFile#
Other Artfinry ID
Re<?o> ante Category: Building Plan
Requirem&nt: Pending 05.14 Provide Technical Report
To determine the acceptability of technologies, processes, products, facilities, materials and uses
attending the design, operation or use of a building or premises subject to the inspection of the
department, the Chief is authorized to require the owner or the person in possession or control of the
building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The
opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety
specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety
properties of the design, operation or use of the building or premises and the facilities and
appurtances situated thereon, to recommend necessary changes.
Page 1 12/11/01
BY G. OHANIAN
DATE
SUBJECT
9-27-02
RACK DESIGN & ENGINEERING CO.
3786 LA CRESCENTA AVE-, SUITE 204
GLENDALE, CA. 91208
TEL:(81B)957-29BO FAX:{818)957-8603
SHEET NO. 1
JOB NO. RD-7237
STRUCTURAL CALCULATIONS OF
STORAGE RACKS FOR:
MV TECHNICAL SALES
194O CAMINO VIDA
CARLSBAD, CA.
PER UBC 1997 EDITION
STORAGE RACKS CAPACITY:
1000 #/ LEVEL
CALCS. 1 THRU 4
DRAWINGS: RD 7237
APPROVED
BY c
OCT 2 5 2002
City of CARLSBAD
BUILDING DEPT.
BY f
DATE
G. OHANIAN
9-27-02
SUBJECT
RACK DESIGN & ENGINEERING CO.
3786 LA CRESCENTA AVE., SUITE 204
GLENDALE, CA. 91208
TEL:(818)957-2980 FAX:(818)957-8603
SHEET NO. 2
JOB NO. RD-7237
144"144
FRONT VIEW-"*"FRONT VIEW-"B"SIDE VIEW -"A"&"8™
99". 106".
I 1
144
FRONT VIEW-"C"FRONT VIEW-"D"SIDE VIEW -"C*'4"D"
BY G. OHANIAN
DATE" 9-27-02
SUBJECT
RACK DESIGN & ENGINEERING CO.
3786 LA CRESCENTA AVE., SUITE 204
GLENDALE, CA. 91208
TEL:(818)957-2980 FAX:(818)957-8603
SHEET NO.
JOB NO.RD-7237
BEAM
1000 #/LEVEL+25% IMPACT LOAD
700 #/BEAM
UBC 1997 SEC. 2222
SEISMIC DESIGN
lx=2.5
Sx = .95
Fy=50
KSI.
R 30
_ SxWxL3
384xlx xE
144_ g»
180
w_ 2.5xCoxl wRx1 4 WOBKIHG
STRESS
LONGIT. DIR. (MOM. CONN.)
TRANSV. DIR. (BRACED)
1=1
R=5.6
R=4.4
Ca = .44
W=D.L+LL.
LOAD PER COLUMN A & D
,- 3X1 K-
LONGIT. SEISMIC
P =1.5
W=.1 + 1.5 =1.6O.L L.L.
V = 2.5x.44x1.6 _
LONG)T- 5.6x1.4
V = 2.5x.44x1.6 _
4.4x1.4
..11
,07
.22"
(A and D)
10
10
LOAD PER COLUMN B 5c C
p_ 4x1 K_oK
2 ~^
W=2.1K
V =.3
LONGIT.
V =-4
TRANS.
..12
..09
..06
.03
.3
(C and B)
BY G. OHANIAN
DATE ~9-27-02
SUBJECT
RACK DESIGN & ENGINEERING CO.
3786 LA CRESCENTA AVE., SUITE 204
GLENDALE, CA, 91208
TEL:(8I8)957-2980 FAX:(818)957~8603
SHEET NO. 4
JOB NO. RD—7237
.£.
i
j
QLUMN ANALYSIS
3" ,,v Kl _ 90 _ 7S Ffl-aixE-- sifc
x-
* FY=50"" '« '•* (*J)'
X x~' v y 4Fe
rx=1-2 „ K
_t='°9 __j ry = 1.08 MQX-Sx.Fb =24 K Pn =Fn xA = 30
COMBINED STRESS RATIO
JU M _ 1.6 . 10 _ s
Pa+ Max" 16 + 24
BASE PLATE
ANCH. TENSION = (10-1.6x3)/6=.8K
ANCHOR SHEAR = -l^i- = .1 1 K
2
(2)-1/2"0 WEDGE TYPE ANCHORS
HILTI KWIK II ICBO #4627 (NO INSPECTION REQ'D)
DESIGNED FOR 1/2 STRESS
1.6
lOOi
10 01 5"x7.75"x3/8'
BASE PLATE
^
f
••• •
ft. \\\J v\\/&
I .• • ""
.'•'•
6"
7.75"
t
•••'•
tv~^.
f* "°,
MOMENT AT BEAM CONNECTION
M, - 4+JO = 7
2
USE 2 PIN CONNECTOR
ALL LEVELS TYP.
2 PIN CONNECTOR
Ma = 3Kx4"x1.33 = 1 e"
CONN.
"K
7/1 6"0 RIVET A = .095 Fy = 79
Va = .095x79x.4 = 3.QK
KSI
7/16"* RIVET
A5TM A3S4-79
TH'K=3/I6"
10
BY G. OHANIAN
DATE 9-28-02
SUBJECT
RACK DESIGN & ENGINEERING CO.
3786 LA CRESCENTA AVE., SUITE 204
GLENDALE, CA. 91208
TEL:(818)957-2980 FAX:(818)957-8603
SHEET NO. 5
JOB NO. RD-7237
TRANSVERSE SEISMIC
(OVERTURNING 8 & C)
MnT=.4Kx2 x194"x.5x1.15 =88*
COL.'OT
MR = 2.1 x42"s=88 K
NO UPLIFT
LOAD TO DIAGONAL
P = .4 x2 x 56. = 1.1COL. 42
KSI
Ffl = 11.2
Pa = 3.5
KSI
(OVERTURNING A & D)
MnT=.3Kx2 x194"x.5x1.15 = 67*Ul COL.
Mp =1.6 x42=67
BOTH SIDES TYP,
FY=50
A=.31
rx=.48
Q=.74
L= 56"
CHECK WELDS
1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL)
3x.125x.707x70x.3=5.7K
SEC. B-B
CHECK SLAB
2100
9"
18"
5" CONCRETE SLAB2000 PSt. CONC.1000 PSF. SOIL
9"
2.1x144=302
V302 =18
2
M =x1000x-i-x12 =735 "#
- 12x5 _50— ;; —<j\J
^^'Si^frs^V^JrtvWe^KayeJssyed ? validI Workers' Compensation insurance policy in » formto the employer named below for the policy period indicated.;^;
^•fy .'*&%fai~*&*-h-^-i4^feit&l&z}t* to'cancellation by the Fund except upon 30days' advance written notice
days' advance notice should this policy be cancelled prior to its normai expiration/.
^nsbfan^e'Js''trtdt an insurance policy and does not amend, extend or alter the coverage ^ffo.rpied
I ."hewiJT.Notwithstanding any requirement, term, or condition of any contract or: otheVdocuhrienf, * _: "• •' «"•
'<••'•> -• Yts^ •-'—»—.-'--.s^-- ,^';|^'S ''d^rtjffcate o( insurance may^ be issued or may'pertain, the insurance afforded :'by^the^v^';; ;:,>"', . ^,.
'^^''-^;*^ subject-to all the terms, exclusions and conditions of such policies,- •:/^^^^^'^i^^.,--';''^.'.^'. /i .
'
Wmfm^^^-;Wi;*!i-vV.;- .''S'^^v,^'; ;•>'.'•••• ..*-'•* '.. - -. .-M--. - -''
P.O.,Sbfe"807, SAN FRANCISCO,CA 94101-0807
WORKERS' COMPENSATION'INSURANCE
POLICY NUMBER;
CERTIFICATE EXPIRES:
DEFENSE COSTS: $1,OOO,OOQ.OO
ADDITIONAL INSURED EMPLOYER EFFECTIVE O1/O1/O2 IS
INSURiD:,'CONVEYOR STORAGE SOLUTIONS ;
HOLDERS' NOTICE EFFECTIVE O1/O1/02
SCIF 102B5(REV,-2-01). ,
ttj