Loading...
HomeMy WebLinkAbout1940 KELLOGG AVE; ; CB972503; PermitB U I L D I N G P E R M I T :l,.0/17/97 13:02 Permit No: ·cB972503 ·Projeet No: A9703184. Page· i of 1 Suite: Development No: Job Addre:ss: 1940 KELLOGG AV '" Permit Type: COMMERCIAL TENANT ·IMPROVEMENT 0375 10/17 i9T iQ.~M'1l· 02 2440-00 Parcel No: 212-170-03-00 Lot#: vaiuation: 59,514 Construction ,Type: NEW :tSSUED 09/04/97 Occupancy Group: pescription: CTI 2289 SF Ref erende# :-Status·: Applied: '' Appl/Ownr: MARSCH RICHARD 1821 VIA QUARTO 760 Apr/Issue; Entered By: 724-8827 10/17/97 JM OCEANSIDE, CA 9 2 0 56 ,,.~-_:, --~·-·-·--. ·***. Fees Required *** ,,,..,.,,,-·*** Fe~ollected & Credits *'** ---· ---____________________ .....,.,..,./ -----.,.,,.r:"J __ ,,,.:~~-----. ~'--------_,. ---------"• -----, . /. /' :r I' I""-.. -~ .· Fees: 2, 791,.ilO --..\ C:.-\ \../ , ti\ C) ,... Adjustrnents: //. Qq~-, )~ "-..:JVTofa.l' sledi s: , 00 Total Fees: 2,791.0~..// Tota±J/&yqi~ts'\· 351.00 I --'/~~ &:i~)i,~)pu~: 2, 4.40. 0-0 . Fee description / ,,., // JpY\(\(\c-i:'iJ~'i ts ~J/Un\t Ext fee Data ------------------------•. ----,. ---------.. 4,! ~---. -----.-,..----------------------- ·Building Permit / fr.,,,,~, / '~;;,' "-::::::::::-.:::::::::....~____;:;.:;,, \ ~ \ 4.60. 00 Plan Check (': "· --.) / ~-·, .. ~-~·-=--:,.,··/ . \ t~.-\ 299. oo. strong Motion Fee :,.:../! n / ··-.. ~ . ...-Al' 1--)1 I· 13. oo Enter "Y" to Autoc~l~:t'j/c~nse T~'~ _. -. . -~~ f ~".::/ 1· 1083. 00 Y Enter ':rraffic Impa~t, Fee \ <:.>,.._ 1 }J~' >( , 777Ji· ./.iJ'i'\~ J · 770. 00 *,BUILDING TOTAL \ .. ' . \c:.::.·-~\,"-,.. . ·( / . _ 2625.00 Enter "Y" ~or P~umbfng Issul"-Eee7~~ ,__/, ~ , ·/ .· ._ · / 20·. O·O Y Each Plumbing Fixtu:t:e or Tra:p / ~ ~ 3 . 7. 0-9 21. o·o * PLUMBING TOTAL , '.' "',, ~--· lf\52 / · -,,. .,, · 48. 0-0 Enter 11 Y11 for Electric\!~~µ~ ff1r ~---7-_J~_.;,, '\\.~ V 10. 00 y Remodel/Alter Per AMP "\,_ '-""\/// /? {2· ~(o)2Gttt\ . 25 · 50. oo :* ELECTRICAL TOTAL . "·< <<) ,:/ / (5 ( ()) ,-~~ \) . . . . 6 0 . 0-0 Enter .;.Y' for Mechanical Issu~Fee·> ~,.) ~ 15.00 Y' Install Furn/Ducts/Heat Pumps· ·-....... __ >.: _____ .~-9·. 00 36. 00 Each Exhaust Fan > 1 6.5~ 6,50 * MECHANICAL TOTAL 58.00 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsba9, CA 92009 (619} 438-1161 FOR OFFICE USE ONLY PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 (760) 438-1161 PLAN CHECK NO. Cf7L5<;_3 EST. VAL. -· _5...,..:Z~'i~L~'i-------~:----- rr,::-~cfiNFQRMA'ffi»C -· : « , ::;:· -. .,__ ... · :> · -810 #~ s, Address (includeBldg/Suite #) ~usiness Name (at this address)' · J ..... Legal Description Lot No. · Subdivision Name/Number 4ft No: Phase No. ·Assessor's Parcel # Existing Use-Proposed Use Total # of units Sbf;tU,,L #of Stories C?{ne6.--~~- #·of Bedrooms # of Bathrooms Name =c==""'-Address -~--City · State/Zip Telephone # Fax # ~JJT~~t~t~R;;;~70.\)j:~~~=qt·,.QW;i~~-~0:-<~:,~~~ Name Address · · · · City · State/Zip Telephone # 14•. "".;eRoPER:rv:oWNER' · · ~-. • •·• · .. • -·-....... ':. ~ , · ,., · .. ··. : .. ,.: . .-·: .. ···., ." ........ --. .-.. ----···:· ., .. ,,/ "',:·;·.,.,. :<,._. ·'>-,~-...r-. :·· .. :··. -<"·· ::-,,,_'f:: ·,.,:.,~,,, .-·~·-· ·· ... ,· .·· .-:. ·_, t:;;i;,;i;ii;-"~~1fi;fiiiiiiliiiiij;;2f5fie,. . ef£71$t;;i4~7;r~ifi;-'ij{217~<1-1:fiiiii2 Name ===~ Address City _..,.,.,,_,__ S.tate/Zip Telephone# ~;'.°';.;.,¢Ji.t1.T.8AOT.OJ'l.,;:t;.'Q9..M?~lllX:t,1~Mi..;.:.,, .. ' _,s.,,··,; .4h;,i.,..~;, ,:0.,~.:.. ;:, , . ;-.,,:w.~·,, ,c ,;:: ..... ·.:.:.;~:.;;, ~,,,,;.~ .::-:.,,,, ;,.;,3;?:J;~~:::..-~:;;:::;.~.:::,:;~,.;~.1.~:,~~' ... :, ;;;;fff';';Z;;.-;., •.. , :;-:0~ '1 (Sec. 7031.5 Business and Professions Code: Any City or County which re):luires a. perrnit to cpnstruct, alter, improve, ·demolish ·or repair any structure, prior to· its issuance, also requires the applicant for such permit to file a signed statement that he is . .licensed pursuant to the provisions of tre <;:ontractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged ·exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a:civil penalty of noh':lore than five hundred d_ollars [$5001). Pd:G Cavsr . .:i..os? 4/tEsrMt,.cr,fz/.,F ~~S&M C,,,f--'t'Joot 76o-7J9-7-/-f--7 Name Address -City State/Zip Telephone# State License # 7 f 4:;S" b 8 License Class B City Business License # -------- Designer Name Acldress City_. State/Zip Telephone State License# _________ _ !§ .. ~ · -WO.BK~'.Cqr.,~NS'A:ff.Q_~ ~~~~~~~~-,H:~-:::~~~:-:,,:...~ , :L:':-'.,~::::~3;~£:.~Z~0.~!S:-¥~~~~f:ri.:~:;:,~;~ Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the followi_ng declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as.provided by Section 3700 of. the Labor Code, for the performance of the work for which this permit is issued. ~ I have and will maintain workers' compensation, as required by Section 3700 of the l:abor Code, for the·,performance of·the work for which this permit is ifs~ed. My worker's c?::!n insurance ~arrier and policy number are: /. ~ Insurance Company ~ Fu.-,,,_cr Policy No. .J-:J: '1-91 / '1 CJ ,:.J Expiration Date /-/ , f 8 . . (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOl:l:ARS ($100] OR·l:ESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manher so as to become subject to the Workers' Compensation Laws of California. · WARNING: Failure to secure workers' compensation coverage is unlawfui, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($10 00), i a ditio the ost of compensation, damages as provided for in Section 3706 of the L!lbor .code, interest and attorney's fees. SIGNATURE_~=...JC:::i.:::......3...<--1,~!,,:f,...£'-'l~r..,______________ DATE /0-1''7 -f 7 £2;;.,,,'..'...QW.~gf!Ji!lUJ~QJ;{l-;'Q.E.C~8'&l!D...N~~, .. ' ,.,:,,. ~:~ ,, ..:_,:_ __ ...;.;;:~;:,,;, :_',;,.'' >· . '..:.:i._,;:.:,,_,..,;;,;;.,. •. ,: ... · :. -"' .: , • .'.:•:t~2£.:l:.:.,:;,::"::,;,:" .21;...•~':';,,':'2: :'.;, ~de.: :t::.~:;;:;;::i;::;,,:-' I hereby affirm that I am exempt·from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employeE)s with wages as their sol!! compensation, will do the· work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor''s License Law does not apply to an owner ·of property who builds or improves there-on, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, howevE!r, the building or improvement is ~old'within,one·year of completion, the owner-builder will have the burden c:>f proving that he did not build or improve for. the purpose of sale). - D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7.044, Business arid Professions Code: The ,Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed, pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and-Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted_ with the following person (firm) to provide the proposed construction (include name I address /-phone number/ contractors license number): 4; I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number>=----~----------------------------------------- 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name./ address/ phone number/ type of work): _________ -'----------------------'-------------,-------------- PROPERTY OWNER SIGNATURE ________________ --'--~~--DATE ________ _ t9..Qfif~~'[tfils:~~§tt.PK!PtiNP.N~~~{PJ,.QIN~f.~)l)~"";YV~: '!..::sT.!;F;:::::·:·::,,:·~~-n?:.'..il!;E:':\2L;}{'i3'Ji,s0r>::::z::~i~-;;7,::-:;3~3r:::~i!~.ZJ Is the applicant or future !)uilcling occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534iof the Presley-Tanner Hazardous Substance Account Act? 0 YES ·o NO .Is the applicant or future building occupant required to obtain a permit from-the air polh,1ti_on control district o'r air quality management district? q YES D NO. Is the facility to be constructed within 1,000 feet of the. outer boundary of a schopl site'? · D YES O NO IFANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED'·UNLESS THE,APPLfCANT HAS MET OR IS MEETING THE REQUIREMENTS-OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION c·oNTROL DISTRICT. ·~~~~ . ~~j:9,Qfl{tBYOIIPJt1,,ffi.pJ~11~~'(~~~=~?-N~-~,,;;:~ 2 _,,;,-__,,-:,, -.:::~ ~:~~0l~5~GI77:~:3~~;*~;;,~~: ;i,: :::';Si~~::;~;~:fu~~--;~:-4~~; q,;c .. ,i:~:;T~-1~?~-~-~y; I hereby affirm that there is a construction lending age_ncy for the performance of the work for :,vhich this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state -that the above information is correct and that the information-on the plans is accurate. I agree to comply with all City ordinances and State laws. relating to building construction, I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN c·oNSEQUENCE OF THE GRANTIN'G OF THiS PERMIT. - -OSHA: An OSHA permit is required for excavations over 5'0" deep and d·~mciiition or construction of structu~es over 3 stories in height. EXPIRATION: Every permit issued by the· Building Official under the provisions of-this Code shall expire by limitation and become null and void if the building or work-authorized by such permit is riot com'meRced wi n 3 5 from the date of such permit or-if the building or work authorized by such permit is suspended or abandoned at any time after the k is com e f · tt·of 80 days (Section 106.4.4 Uniform BuildinQ Code). APPLICANT'S SIGNATURE L__,:::~~~.2.~~LJ~~:__~==::::=-----~----DATE _2_-_f,,__·~f,,__7 ______ _ WHITE: File YEL:LOW: Appiit:ant PINK: Finance 10/17/97 13:01 Page. 1 of 1 Job Address: 1940 KELLOGG AV SEWER Permit Type: SEWER -OFF.ICE/WAREHOUSE Parcel No: 212-170-03-00 Description: CTI 2289 SF· : WAREHOUSE TO OFFICE P E R M I T Suite:·· Permit No~ SE970:l,.67, Bldg PlanCk#: CB972503 0375 10/17/97 0001 01 c..:PRMT 'St!:ttUS: App.lied: 02 . 1528!'00 ISSUED 09/29/97 10/17/97 Permite-e: MARSCH RICHARD 760 Apr/Issue: 724_'.8827· . · Expired.: 1821 VIA QUARTO ·ocEANSIDE, CA 92056 : -• ·, r r n r ,· .. : ·-~' r.f\.. ' ,-ff ,, , :i t "1 ...... .. -"cl -.J u u u J V 'lh ...... CITY OF CARLSBAD· ·· 'Prer;:,ared By: 2075 Las Falmas Dr., Carlsbad, CA.''92009 (619) 438-ll(jl MAM. PERMIT# CB972503 DESCRIPTION: CTI 2289 SF CITY OF CARLSBAD · INSPECTI-ON REQUEST FOR 01/13/98 INSPECTOR AREA TP PLANCK# CB972503 OCC GRP TYPE: CTI JOB ADDRESS: 1940 KELLOGG AV APPLICANT: MARSCH RICHARD CONTRACTOR: OWNER: REMARKS: C/GARTH/ 619 /9 69-·054 7 SPECIAL INSTRUCT: AM PLEASE TOTAL '11IME: --RELATED PERMITS--PERMIT# WM970029 SE970.167 TYPE WMETER swow STE: CONSTR. TYPE NEW LOT: PHONE: 760 724-8827 PHONE: ~ PHONE: INSPECTOR . -...,,,,,_ _________ _ STATUS ISSUED ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final structural /11!_ ______ _ 29 PL Fi:p.al Plumbing 39 EL Final Electrical 49 ME Final Mechanical t--- --------~--------- --------'---------------,--------~------- ***** INSPECTION HISTORY***** DATE DESCRIPTION 010698 Final Combo 123197 Final Combo 122397 Frame/Steel/Bolting/Welding 1223·97 Rough Electric 122397 Rough/Ducts/Dampers 122297 Rough Combo 112597 Interior Lath/Drywali 112497 Interior Lath/Drywall 112197 Insulation i12097 Rough/Topout 112097 Rough/Ducts/Dampers 112097 Rough ·Electric 112097 Frame/Steel/Bolting/Welding 111997 Rough Combo 111897 Rough Combo 102997 Underground/Under Floor ACT co co AP AP AP NR AP co AP AP AP AP AP co NR PA INSP TP TP PS PS PS PS TP TP TP TP TP TP TP TP TP TP COMMENTS SEE CORR LIST ATCH PART INSP/SEE CARD T-BAR T-BAR T-BAR NR FORT-BAR/ND TO COMP ELEC NOT COMP EXHST DUCTS WALLS WATER TEST,NEED A/B U.G. REV. FINAL' BUILDING INSPECTION DEPT: BUILDING ENGINEERING <~· PLANNING U/M WATER PLAN CHECK#: CB972503 PERMIT#: CB972503 PROJECT NAME: CTI 2289 SF ADDRESS: 1940 KELLOGG AV CONTACT PERSON/PHONE#: C/GARY/967-2400 SEWER DIST: CA . WATER DIST: CA INSP~ BY: ~--..Lo,/,.-a......., INSPECTED BY: INSPEC-TED BY': ===..- COMMENTS: DATE I l INSPECTED: 1 ~ 9B DATE INSPECTED: DATE INSPECTED: APPROVED APPROVED DATE: 12/31/97 PERMIT TYPE: CTI DISAPPROVED DISAPPROVED DISAPPROVED . . . . from/ // IJ l'J;ffJIP//7c)' - , 7 . / _ ~, 7tv-72/--/ft"7 I . ---- EsGil Corporation Professional Pftm. !l{.eview 'Engineers DATE: 9/29/97 JURISDICTION: Carlsbad Pl.AN CHECK NO.: 97-2503 PROJECT ADDRESS: 1940 Kellog ~t. PROJECT NAME: Wayne Foster, Inc. TI SET: II ~ .. ANT. JURI . CJ N REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. • The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: • Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Mail Telephone Fax In Person • RiMARKS: 1. New sheets A-2, A-4 & M-1 at the city must b n porated into the city set of plans. 2. lr1clude in the city set of plans the clouded notes fo ' · on sheet A-5 of the plans from EsGil. 3. City is to verify that the access from the handicap d parking to the tenant space complies with the current access standards. By: Chuck Mendenhall _ Esgil Corporation D GA D CM D EJ D PC 9/22/97 Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 EsGil Corporation· Professionaf Pftm !l(eview 'Engineers DATE: 9/16/97 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-2503 PROJECT ADDRESS: 1940 Kellog St. PROJECT NAME: Wayne Foster, Inc., TI SET:I D APPLICANT ~ ~EVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved an·d checked by building department staff. · D The plans transmitted herewith have significant deficiencies id~ntified on the enclosed check list and should be corrected and resubmitted for a complete recheck. • The check list transmitted he·rewith. is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy_of the .check list is enclosed for the jurisdiction to forward to the applicant contact person. • The applicant's copy of the check list has been sent to: Richard Marsch 1825 Via Quarto, Oceanside, CA 92056 • Esgil Corporation staff did not·advise the applicant (except by mail) that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. · Person contacted: Telephone#: Date contacted: (by: ) Mail Telephone Fax In Person D REMARKS: By: C)luck Mendenhall E:sgil Corporation D GA D CM D EJ D ~c 9/9/97 Fax#: Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 Carlsbad 97-2503 9/16/97 PLAN Rl:VIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 97-2503 OCCUPANCY: B TYPE OF 'CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: REMARKS: DATE PLANS RECSIVED BY JURISDICTION: 9/4/97 JURISDICTION: Carlsbad USE: Office ACTUAL AREA: 2289 STORIES: HEIGHT: OCCUPANT LOAD: 42 DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/9/97 DATE INITIAL PLAN REVIEW COMPLETED: 9/ 16/97 . PLAN REVIEWER: Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code,. Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be requited prior to the is·suance of a building permit. Code sections cited are based on the 1994 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, ·1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck proces~. please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet .number, specification section, etc. Be sure to enclose the marked up list when you submit the ·revised. plans . .LIST NO. 40, TENANT IMRROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot Carlsbad 97-2503 9/16/97 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one.of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering_ and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. · 2. In areas where the o_ccupant load exceeds 30 two exits are required. See UBC. Table 10-A. The occupant load of the tenant space with conference rm is 42. Provide two exits from this space. 3. Exits should have a minimum separation of one-half the maximum overall diagonal dimension of the building or area served. Section 1003.3. 4. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1013.1. 5. Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction. UBC 1005. 6. One-hour fire-rated corridors shall -have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings in interior·walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 713.2. Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 1005.8.1. 7. Window openings in the ·1 HR corridor shall be protected by fixed glazing listed and labeled for a fire-protection rating of at least 3/4-hour. Section 713.9. 8. If a room with an exhaust fan has a door opening into a rated corridor, show how makeup air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 1005.8.1. This applies to the bath rms opening into the corridor. Carlsbad 97-2503 9/'16/97 9. Clearly show Where the non-rated corridor system terminates and a rated corridor system commences. 10. Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. 11. Smoke/Fire dampers shall be installed per Section 713.1 0 at all ducted or unducted air -openings at penetrations of: a) The fire-resistive construction of corridors. 12. Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 1005. 7. 13. Specify lever-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24. 14. Show on the plans the required wall and ceiling insulation as required by the energy design. · • MECHANICAL 15. Note on the plans that the mechanical ventilation in all rooms capable of supplying outside air at a minimum rate. of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1 · 16. Detail disposal of main condensate drainage from air conditioning units. (UMC Section 310) • CITY OF CARLS8AD SUPPLEMENT 17. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). 18. No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building_ Official. (City Policy) 19: All roof-mounted equipment shall be concealed from view. Provide structural detailing for the screening. DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL TITLE 24 DISABLED 'ACCESS REQUIREMENTS • REMODELS, ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that builging, or portion of the building affected is required to comply with all of the Carlsbad 97-2503 9/16/97 requirements for new buildings, per Section 1134B.2. These requirements apply only to the area of specific alteration, repair or addition and shall include: a) A primary entrance to the building and the primary path of travel to the area in question, and include the following items which serve the area in question: • SITE PLAN REQUIREMENTS 2. Clearly show that the site development the location of the disabled accessible parking and the path of travel to the tenant space. To speed up the review process, note on this list (or a copy) where each correction ,item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and Where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please · indicate: Yes CJ No CJ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 97-2503 9/16/97 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsb~d PLAN CHECK NO.: 97-2503 PREPARED BY: Chuck Menden,hall DATE: 9/16/97 BUILDING ADDRESS: 1940 Kellog St. BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BU'!LDING PORtlON BUILDING AREA VALUATION VALUE (ft. 2) MULTIPLIER ($) Tl 2289 26 59,514 - Air Conditioning Fire Sprinklers TOTAL VALUE 59,514 • 1991 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ 459.50 • 1991 UBC Plan Check Fee D Plan Check Fee by ordinance: $ 298.68 Type of Review: • Complete Review D Structural Only D Hourly D Repetitive Fee Applicable D Other: Esgil Plan Review Fee: $ 238.94 Comments: Sheet 1 of 1 macvalue.doc 5196 - ·- City of Carlsbad M#ih·ii,t441ih•i•l4·SIUl,t4h• BUILDING PLANCHECK CHECKLIST ·DATE: 9°-aq-_q_7. PLANCHECKNO.: CBCl7d503 BUILDING ADDRESS: /14-0 f0. I/_ ~co ~ _ PROJECT DESCRIPTION: ;;/ J, RCJ '.f;;{ ~"pj ~~ ASSESSOR'S 'PARCEL NUMBER: _________ EST. VAt:. : ENGINEERING DEPARTMENT APPROVAL . DENIAL The item you have submitted for review has been approvec!. · The approval is based on plans, inf9rmation and/or specifications provided in your submittal; therefore any changes to these items after this date-, including field modifications, must be reviewed by this office to insure c:9ntinued conformance with-applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report · can r~sult in · suspension of permit to build. A Right-of-Way permit is required prior to construction of the following improvements: Please see the attached report of deficiencies marked with D. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or .specifications to this office for review. By: Date: 'By: --------Date: By: --------Date: FOR OFFICIAL USE ONLY ENGINEERING:AUTHO~IZATiON:-0 I -~UILDING'PERMIT: -· -/17 --9 ~ 7· a7 -' , ----/ . : _-_ _ _ . : , .-· .Date: ___ --' _ _,;_ __ __,L.. ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet Sew~r Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: Michele Masterson City of Carlsbad Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Phone: _(619) 438-1161, ext. 4315 CFD INFORMATION _Parcel Map No: Lots: Recordation: Carlsbad Tract: A-4 \\LASPALMASISYS\LIBRARY\ENGIWORD\DOCS\CHKLST\Bulkfing Plancheck Cklst BPD001 Form MM,doc .,. Rev,o9103'~075 Las Palmas Dr.• Car.lsbad, CA 92009-~ 576 • (619) 438-1161 • FAX (619) 438-0894 ( . .. A ST.1/';ND.I di ~ lo D BUILDING PLANCHECK CHECKLIST .SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines B. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets G. Driveway widths 2. Show on site plan: A Drainage Patterns . 1. Building pad surface drainage must maintain a minimum slope of one .percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography 0 . 3. Include on title $heet: D A. Site adQress B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer· permits showing Square footage of different uses (manufacturing, . warehouse, office, etc.) previously approved. EXISTING PgRMIT NUMBER DESCRIPTION DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. _____________________________ _ 4b. All c~mditiolis are in compliance. Date: __________ _ ~~::~~:tSYS\LIB~RYIENG\WORD\OOCSICHKLST1Bulld1ng Plancheck Cklst BP0001 Fonn MM.dqc _-2 0 0 0 0 0 0 BUILDING PLANCHECK CHECKLIST . DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a v1;1lue at or exceeding $ ______ , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required 8$ follows: _________________ _ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 ½" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completec;f by: ___________ _ Date: ----- IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ _______ , pursuant to Carlsbad Municipal Code Section 18.40.040 .. Public improvements requited as follows: _____________ _ Attai;;hed please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the· apprc;>priate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be· submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed bf ___________ _ Date: ____ _ 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1.8.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ _______ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future pub_lic improvements required as follows: \\LASPALMASISYS\LIBRARYIENG\WORD\DOCS\CHKLST\Building Plancheck Cklst BR0001"Fonn MM.doc Rev. 09/03/97 3 1 st.r . 2ndJ' 3rdJ' 0 0 0 0 0 0 0 0 0 0 0 0 0 aUILDING PLANCHECK CHECKLIST 6c. E_nclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: . 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective ·improvements found adjacent to building site must be. repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal -Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). Write · "No Grading" on plot plan if none is required. 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must· be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not teqtJii"ed.) 7d.No Grading Permit required. 7~.lf grading i$ not required, write "No Grading" on plot plan. MISCELLANEOUS PERMltS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for: I\LASPALMASl~YS\LIBRARY\ENG\WORD\oocs1cHKLST\Buikfing Plancheck Cklst BP0001 Fonn MM.doc • 4 Rev:09/03/97 i:J i:J [j BUILDING PLANCHECK CHECKLIST 9. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. i:J 10. INDUSTRIALWASTE PERMIT If your .facility is located-in the City of Carlsbad i:J sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for assistance. Industrial Waste ,permit accepted by: Date: 11. NPDES PERMIT Complies with the City's r~quirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occur7st. . 12. ~equired fees are attached i:J No fees required / 13. Additional Comments: l\lASPALMAS\SYS\LIBRARY\ENGIWORD\DOCSICHKLST\B4ildmg Plancheck Cklst BPOJ)01 Fof!TI MM.doc 5 Rev. 09/03/97 · '· _ ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET ~· Estimate based on unconfirmed information from applicant. I Calculation based on building plancheck plan submittal. Address: I q + 0 f5 e /lc,@'J t4-u e__. Bldg. Permit No. C 8 q Zd ;So -2 Prepared by(/7/.l(}\__ Date: 1/4-1 /q 7 Checked by: ____ Date: ____ _ EDU CALCULATIONS: tist type's and sq1,1are foot8J}es for all uses. · · le)are lfot1se . . .;<. .;l 89 Types of Use:c/o t) f{l'e ,e Sq. Ft._/~: _____ _ o t-f--re..-e --~,;)_, ~ q ~ /~ () 0 tu,,u,-t._fttY&t.S-e. -:;l. :J....t"J· 7 5 000 ADT .CALCULATIONS: List types and square footages for all uses. ' Wctre kt,u s-e. . <J ---> 8-c:, Types of Use: <Y'c, o:-h';E'.t'C e___ Sq. Ft./.~ -~'-'---c:7\ __ -_t_ ef-f'tc.-e_ -,;i<yjo-,,o. . (,uq_r-e)i.c,u...-s "?-.-000 D FEES REQUIRED: /. ;l. 7 EDU'·s: C::.6 41,'). ----- 0 8 I 46 ADT's: L /I> 35 PUBLIC FACILITIES FEE REQUIRED: D YES D NO (See Building Department for amount) WITHIN CFO: m--1ES (no bridge & thoroughfare fee, reduced Traffic Impact Fee) D NO ~K-IN-LIEU FEE PARK AREA: __ _ / FEE/UNIT: lzr 2. TRAFFIC IMPACT FEE ADT's/UNITS: s 5 ~OGE .AND THOROUGHFARE FEE ADT's/UNITS: . ~AGILITIES MANA~EME!')T FEE X NO. UNITS: __ _ X FEE/ADT: X FEE/ADT: ___ _ ZONE: --~- =$ =$ / UNIT/SQ.FT.: X FEE/SQ.FT./UNIT: ___ _ =$ ~ 5. SEWER FEE PERMIT No.S{?~ q 70 / 6 7 x FEE/EDU: / g I 0 DRAIN~GE BASIN: 5 F EDU's: 0;, 8 [ BENEFIT AREA: C-v EDU's: e:,_ '3 f ~ DRAINAGE FEES PLDA. ___ _ ACRES: X ¥-;~WER LATERAL ($2,500) X FEE/EDU: 7 "' HIGH ___ /LOW __ _ FEE/AC: __ _ =$ =$ =$ =$ 77() e- o-. I) f.ftp I:, . C:, ;;L 0 C) - TOTAL OF ABOVE FEES*:$ d,t ~ q 2 * NOTE: This calculation sheet is NOT a complete list ~f all fees which may be due. Dedic~tions and Improvements may also be required with Building Permits. P:\DOCS\MISFORMS\BP0002.FRM REV 01/22/97 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB CJ J~ 5C> 3> -DATE __ 1__,)~~_,_i;/2_7 ___ 7 _______ _ ADDRESS / cf {j:1) ked, C-· . . u RESIDENTIAL RESIDENTIAL ADDiTION MINOR ( < $1 0,000.0O) -~--/ cJ u iD~ ~rePt~&owrJ ~~,~ . C PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING -ENGINEER _____________ DATE ______ _ C:\WP5"1 \FILES\BLOG.FRM Rev 11 /15/90 . City of Carlsbad ·· 97304 Fire Department • B1;1reau of Prevention . Plan Review: Requirements Category: Building Plan Check , Date of Report: Tuesday, September 16, 1997 Reviewed by:_%-·-~=-"-%f&=--.· ,.=,,.___"'_ Contact Name Richard Marsch· Address 6640 Lusk Bl Suite 205C City, State San Diego CA 92121 Bldg. Dept. No. CB97-250·3 Planning No. Job Name Wayne Foster Ent Job Address _1_9_40_K_el_lo~gg _____________ _ Ste. or Bldg. No. ____ _ 181 Approved -The item you have submitted for review has been approved. The approval is based on plaAs; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in thi$ report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st. __ _ 2nd __ _ 3rd. __ _ Other Agency ID CFO Job# __ 97_3_0_4 __ File# __ ~_ 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121 TITLE 24 REPORT FOR: Wayne Foster Entertainment 1540 Kellog Drive Carlsbad, CA 92009 PROJECT DESIGNER: Steve White 6351 Corte Del Abeto, Suite A100 C~rlsbaQ, CA 92009 (760) 931-1130 REPORT PREPARED BY: Henry Razouk, PE Henry Razouk 3291 Celi-nda Drive Carlsbad, CA 92008 ('760) 434-3433 Job Number: 97-1008 Date: 9/3/1997 The COMPLY 24 computer program has been used to perform the calculations summarized in this compliance report. Th:i;s. program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential Buildirig Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, llc (415) 883-5900. Table Of Contents for Title 24 Report Cover Page .................................. -· . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . • . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Form ENV-1 Form ENV-2 Form L'i'G-1 Form LTG-2 Form MECH-1 Form MECH-2 Envelope Cert if ica te of Compl ianc·e . . . . . . . . . . . . . . . . . . . . . . . 3 Prescriptive Envelope Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Lighting Certificate of Compliance ....................... 9 Prescriptive Lighting Compliance Summary ................. 11 Mechanical Certificate of Compliance .................... 12 Prescriptive Mechanical Summary ......................... 15 Form MECH-3 Mechanical Equipment Sum~qry ............................. 18 Form MECH-4 Mechanical Ventilation .................................. 19 HVAC $ystem ioads Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Zone Loads Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 CERTIFICATE OF COMPLIANCE -Envelope (part 1 of 2) ENV-1 page 3 of 25 ------.--------------------------------------------------------------------Project Name: Wayne Foster Entertainment Address: 1540 Kellog Drj.ve Carlsbad, CA 92009 Envelope Designer: Steve White Documentation: Henry Razouk Date: 9/3/1997 Building Permit No Checked by/ Date COMPLY 24 User 3268 -----------------·--------, ------------------------------------------------ GENERAL INFORMATION Date of Plans:______ Building Conditioned Floor Area: 2239 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: O New Construction O Addition O Alteration Method of Envelope Compliance: Prescriptive -Overall Envelope STATEMENT OF COMPLIANCE This Certificate of. Compliance lists the·Building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the Calif- ornia Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR Henry Razouk, PE (760) 434-3433 (Signature) (Date) The Principal Envelope Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in sec-tions 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6, Chapter 1. Please check one: O I hereby affir~ that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer or architect. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section ____ of the _______ _ Code to sign this document as the person responsible for its preparation; and for the following reason: ______________ _ PRINCIPAL ENVELOPE DESIGNER Steve White ( 76O~) 9-31-1130 (Signature) (Lie. #) (Date) ENVELOPE MANDATORY MEASURES Indicate location on plans .of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE -Envelope (part 2 of 2) ENV-1 page 4 of 25 --------------------------------------------· ------------------------------P~oject Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 user 3268 ----·--------------------------.------------------------------------------- OPAQUE SURFACES Assembly Name ________________ , _____ _ R-11 Metal Stud Wall R-19 Roof (R.19.2x8.16) R-30 Roof(R.30.2x12.16) 6 ;, Concrete Wall Solid Wood Door FENtSTRATION Frame Orient Panes Type ------------------ Front (S) 2 Metal Left (W) 2 Metal Left (W) 2 Metal Const Type Location/Comments Note to Field ---,-----------------------------Metal Wood Wood None None Exterior Shade -------------------.---None None None OH N N N Glazing Type I I I I I I I I I I ------------------------ Gray Lite (N) Gray Lite (N) Gray Lite (N) OVERALL ENVELOPE METHOD (part 1 of 4) ENV-2 page 5 of 25 -----------------------------,---------------------------------------------Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 ---------------------------------------------------------------------------- WINDOW AREA TEST A. Display Perimeter 0.0 ft X 6 ft = 0.0 sf Display Area B. Gros-s Exterior Wall Area 1691.0 sf X 0.40 = 676.4 sf 40% Area c. Gross Exterior Wall Area 1691.0 sf X 0.10 = 169.1 sf Min Std Area D. Enter Larger of A or B 676.4 sf Max Std Area E. Enter Proposed Window Area 539.0 sf Proposed Area If E i~ greater than Dor less than C, proceed to for window area adjustment. If not, go to part 2 the next of 4. calculation 1. If Eis greater than D: D. Maximum Standard Area --------------------- N/A I 2. If Eis less than C: c. Minimum s·tandard Area ----------------, ------- N/A I Window E. Proposed Area . Adjustment Factor N/A E. Proposed Area N/A = = N/A Window Adjustment Factor N/A --------------------------------------------------------------------------- SKYLIGHT AREA TEST Atrium Height 0.0 ft If Height< 55 ft If Height>= 55 ft Standard= 5% ---------+----------Standard= 10% I I V A. Gross Exterior Roof Area i239.0 sf X 0.05 = 112.0 sf Standard Area B. Enter Proposed Skylight Area 0.0 sf Proposed Area If the Proposed Skylight Area is greater than the Standard Skylight Area, proceed to the next calculation fo~ the skylight area adjustment. If not got to part 2 of 4. 1. If Proposed Skylight Area> Standard Skylight Area: Standard Skylight Area Proposed Skiiight Area -------------------------------------------- N/A I N/A = Skylight Adjustment Factor N/A OVERALL ENVELOPE METHOD (part 2 of 4) ENV-2 page 6 of 25 -· --------------------------------· --.-------------------------------------Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 ------------------·-------------------------·------------------------------ OVERALL HEAT LOSS PROPOSED Adj. STANDARD Ass~mJ:>ly Name Area HC U-Val UxA Area U-Val UxA ---------------------------------------------------------6 II Concrete Wall 163.0 14.0 0.752 122.6 163.0 0.430 70.1 6 II Concrete Wall 54.0 14.0 0.752 40.6 54.0 0.430 23.2 6 ti Concrete Wall 132.0 14.0 0.752 99.2 132.0 0.430 56.8 R-30 Roof{R.30.2~12.16) 626.0 2.7 0. 03-5 21.7 626.0 0.078 48.8 Gray Lite (N) 63.0 N/A 0.500 31.5 63.0 1.230 77.5 Gray Lite (N) 58.0 N/A 0.500 29.0 58.0 1.230 71.3 Gray Lite (N) 58.0 N/A 0.500 29.0 58.0 1.230 71.3 6 ti Concrete Wall 161.0 14.0 0.752 121.1 161.0 0.430 69.2 R-11 Metal Stud Wall 71.0 2.6 0.189 13.4 71.0 0.189 13.4 R-11 Metal Stud Wall 511.0 2.6 0.189 96.5 511.0 0.189 96.6 R--19 Roof (R.19.2x8.16) 1262.0 2.3 0.051 64.6 1262.0 0.078 98.4 R-19 Roof (R.19.2x:8.16) 351.0 2.3 -0. 051 18.0 351.0 0.078 27.4 Gray Lite (N) 117.0 N/A 0.500 58.5 117.0 1.230 143.9 Gray Lite (N) 243.0 N/A 0.500 121.5 243.0 1.230 298.9 ------------ Total 867.2 Total 1166.9 ** OVERALL HEAT LOSS COMPLIES PROPOSED UA <= STANDARD UA ** OVERALL ENVELOPE METHOD (part 3 of 4) ENV-2 page 7 of 25 ---------------------------------------------------------------------------Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 ----.. ______________ " _____________________ . --------------------------------- OVERALL HEAT GAIN PROPOSED STANDARD Glazing WF Area SC H V OHF Total Area RSHG Total ------------------------------------------- West 1.34 63.0 0.40 33.8 63 .. 0 0.71 59.9 ·west 1.34 58.0 0.40 31.1 58.0 0.71 55.2 West 1.34 58.0 0.40 31.1 58.0 0.71 55.2 South 1.31 117.0 0.40 61.3 117.0 0.71 108.8 West 1.34 243.0 0.40 130.2 243.0 0.71 231.2 ------------- Total 287.5 Total 510.3 ** OVERALL HEAT GAIN COMPLIES PROPOSED HG<= STANDARD HG** OVERALL ENVELOPE METHOD (part 4 of 4) ENV-2 page 8 of 25 ________ , _______________ ·--------.----.------------------------------------ Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 -----,.------------------------------------·-------------------------------- Window Area Adjustment Calculations Adjusted Gross Door Window Adjust Window Wall Wall N~me Dir Area Area Area Factor Area Area ----------·-------.---------------------------------------- North Wall N 163.0 0.0 1.0000 0.0 163.0 South WALL s 54.0 0.0 1.0000 0.0 54.0 West WALL w 311.0 179.0 1.-0000 179.0 132.0 North WALL (EXT) N 161.0 0.0 1.0000 0.0 161.0 North (INT) N 91.0 20.0 0.0 1.0000 o.o 71.0 East WALL (INT) E 551.0 40.0 0.0 1.0000 0.0 511.0 South WALL s 117.0 117.0 1.0000 117.0 0.0 West WALL w 243.0 243.0 1.0000 243.0 0.0 ----------------------------- TOTALS 1691.0 60.0 539.0 539.0 1092.0 Skylight Area Adjustment Calculations Adjusted Gross Skylt Adjust Skylt Roof Roo.f Name Dir Area Area Factor Area Area ---------------------------------------------------- Roof H 626.0 0.0 0.0000 0.0 626.0 Roof H 1262.0 0.0 0.0000 0.0 1262.0 Roof H. 351.0 0.0 0.0000 0.0 351.0 ----------------------- TOTALS 2239.0 0.0 0.0 2239.0 CERTIFICATE OF COMPLIANCE -Lighting (part 1 of 2) LTG-1 page 9 of 25 -----------------~---------------------------------------------------------Project Name: Wayne Foster Entertainment Address~ 1540 Kellog Drive Carlsbad, CA 92009 Lighting Designer: Documentation: Henry Razouk :Date: 9/3/1997 I ·----------:Building Permit No I ·----------: checked by/ Date I I :coMPLY 24 User 3268 -------------·----------------------------·-----· wl ------------------------ GENERAL INFORMATION Date of Plans: Building Conditioned Floor Area: 2239 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: O New Construction O Addition O Alteration Method of Lighting Compliance: Prescriptive STATEMENT OF COMPLIANCE This c·ertificate of Compliance lists the Building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the Calif- ornia Code of Regulations. This certificate applies only to building lighting requirements. ' ·The documentation preparer hereby certifies that the documentation is accurate and complete. DOCUMENTATION AUTHOR Henry Razouk, PE (760) 434-3433 (Signature) (Date) The Principal Lighting Designer hereby certifies that the proposed build- ing design ~epresented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the lighting requirements contained in sections 110, 119, 13.0 through 132 and 146 or 149. Please check one: o I hereby affirm that I am eligible under the provisions of Division 3 of the Business and P.rofessions Code to sign this document as the person·responsible for its preparation; and that I am a civil engineer electrical engineer or a~chitect. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work that I have contracted to perform. o I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section ____ of the Code to Sign this document as the person responsible for its preparation; and for the following reason: ______________ _ PRINCIPAL LIGHTING DESIGNER (S.rgnature) (Lie. #) (Date) LIGHTING MANDATORY MEASURES Indica.te location on plans of No-te Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE -Lighting (part 2 of 2) LTG-1 page 10 of 25 -----------.--------------------------------------.------------------------Project Name: Wayne. Foster Entertainment Documentation: Henry Razouk INSTALLED LIGHTING ·SCHEDULE No of Name Lamp Type Lamps ----------------------- A Fluorescent 3 MANDATORY AUTOMATIC CONTROLS Control Watts/ Ballast Lamp Type -----------------34 Standard :Date: 9/3/1997 I I :coMPLY 24 User 3268 Ballasts/ No of Note to Luminaire Fixt. Field . -------------------- 1.5 13 Control Location ID Control Type Zone Controlled Note to Field CONTROLS FOR CREDIT Control Control Location ID Control Type Zone ·Controlled Note to Field LIGHTING COMPLIANCE SUMMARY LTG-2 page 11 of 25 --------------------------------------_" __________ ·------------------------ Project Name: Wayne Foster Entertainment Documentation: Henry Razouk ACTUAL LIGHTING POWER Name Description No of Lumin :Date: 9/3/1997 I I :coMPLY 24 user 3268 Watts Total per Default Watts -------------------------------------------------------------------- A 48" T-12 Low Watt /3 Lamp (Tandem) 13 108.0 1404.0 SubTotal 1404 Less Control Credits (LTG-3) O Total Proposed Watts 1404 * If not CEC Default value, please provide supporting documentation. ALLOWED LIGHTING POWER BY ZONE Zone Name Western Offices Zl East Offices Z2 CONFERENCE Z3 Occqpancy Office Office Convention/Conference TOTALS Floor Area ----- 626 1262 351 ----- 2239 Allowed LPD (w/sf) ------ 1.600 1.600 1.600 ------ 1.600 Total Tailored (watts) (watts) -------------- 1002 0 2019 0 562 0 -------------- 3582 0 * Note: Tailored Allotment requires supporting documentation on form LTG-4. CERTIFICATE OF COMPtIANCE -Mechanical (part 1 of 3) MECH-1 page 12 of 25 -----:_--------------------------------------------------------------------'Project Name: Wayne Foster Entertainment Address: 1540 Kellog Drive Carlsbad, CA 92009 Mechanical Designer: West-Air Mechanical Documen·tation: Henry Razouk Date: 9/3/1997 Building Permit No Checked by/ Date COMPLY 24 User 3268 -------------------------------------------··------------------------------- GENERAL INFORMATION Date of Plans:______ auilding conditioned Floor Area: 2239 sf Building Type: Nonresidential Climate Zone: 7 Phase of Construction: O New Construction O Add-ition O Alteration Method of Mechanical Compliance: Prescriptive Proof of Envelope Compliance: O Previous Permit O Compliance Attached STATEMENT OF COMPLIANCE This Certificate of Compliance lists the Building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the Calif- ornia Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby .certifies that the documentation is accurate and compl~te. DOCUMENTATION AUTHOR Henry Razouk, PE (760) 434-3433 (Signature) (Date) The Principal Mechanical Designer hereby certifies that the proposed build- ing design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed Building has been designed to meet the mechanical requirements contained in sections 110 through 115, 120 through 124, 140 through 142, 144 and 145. · Please check one: O I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer mechanical engineer or architect. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing docu- ments for work. that I have c·ontracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section---,----of the Code to sign this document as the person responsible for its preparation; and for the following reason: ______________ _ PRINCIPAL MECHANICAL DESIGNER West~Air Mechanical ( 760) 529-8787 MECHANICAL MANDATORY MEASURES (Signature) (Lie. #) (Date) Indicate location on plans of Note Block for Mandatory Measures: CERTIFICATE OF COMPLIANCE -Mechanical (part 2 of 3) MECH-1 page 13 of 25 ·----------------------------------------------·---------------------------Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 -----------------------------------·--------------------------------------- SYSTEM FEATURES Zone Name Time Control Setback Control #of Isolation Zones HP Thermostat Electric Heat Fan Control VAV Min Pos.i tion Simul. Heat/Cool Heat Supply Reset Cool Supply Reset Ventilation OA Damper Control Economizer Type Outdoor Air CFM Heat·Equip Type Make & Model No. Cool Equip 'J_'ype Make and Model Zone Name Time. Control Setb.ack Control #of Isolation Zones HP Thermostat Electric Heat Fan Control VAV Min Position Simul. Heat/Cool Heat Supply Reset Cool Supply Reset Ventilation OA Damper Control Economizer Type Outdoor Air CFM Heat Equip Type Make & Model No. Cool Equip Type Make and Model Code Tables Time Control S:Prog Switch O:Occ Sensor M:Man Timer HP-1 (Zl.) 5 ' Setback n/a Yes 7.5 KW Constant Volume n/a n/a Constant Temp Constant Temp c No Economizer 47 HP-2 (Z2) s Setback n/a Yes 7.5 KW Consta,nt Volume n/a n/a Constant Temp Constant Temp C N CqE . o conom1zer 95 Heat Pump Heat Pump CARRIER 50HS~036---301-CARRIER SOHS-036---301- DX DX HP--3 (Z3) 5 Setback n/a Yes 5.0 KW Constant Volume n/a n/a Constant Temp Constant Temp C No Economizer 176 Heat Pump CARRIER SOHS-024---301- DX Ventilation B:Air Balance C:OA Cert. M:OA Measure D:Demand Cont N:Na,tural OA Damper A:Auto G:Gravity Note to Field CERTIFICATE OF COMPLIANCE -Mechanical (part 3 of 3) MECH-1 page 14 of 25 ----------------------------------·----------------------------------------Projec,t Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 user 3268 --------------------------------------------------------------------------- DUCT INSULATION System Name Type Duct Location Duct Tape Insul Note to Allowed R-Val Field -------------------------------------------------------------------- CARRIER SOHS-036---301-Heating Ducts in Attic Cooling Ducts in Attic CARRIER SOIJS-036---301-Heating Ducts in Attic Cooling Ducts in Attic CARRIER SOHS-024---301-Heating Ducts in Attic Cooling Ducts in Attic PI'PE INSULATION System Name Pipe Type ----------------------------------Do~estic Hot Water Insu·1 Required y / N NOTES TO FIELD -For Building Department Use Only l~: f IN flt I N r!)I N 4.2 4.2 4.2 4.2 4.2 4.2 Note to Field MECHANICAL SIZlNG AND FAN POWER MECH-2 page 15 of 25 ------------------------------------------·--------------'-----------------Project Name: Wayne Foster Entertainment Documentation: Henry Razou~ :Date: '}/3/1997 I I :coMPLY 24 User 3268 _____ ,_ ·------------------------------------------------------------------- SIZING AND EQUIPMENT SELECTION HVAC System Name: Heating System Name: Cooling System Name: System ~ultiplier: Peak Load Method: Relative Humidity: 1. DESIGN CONDITIONS FOR Carlsbad 2. SIZING ZONES SERVED BY SYSTEM Western Offices Z1 PEAK (Jan 12am} TOTAL ZONE LOAD Duct Gains & Losses: Ventilation: ( Return Air Lighting Gain Supply/Return Fan Gain: 47 CFM) TOTAL SYSTEM LOAD 3. SELECTION A. Safety/Warmup Factor B. Maximum Adjusted Load C. Installed Equipment Capacity HP-1 (Zl) CARRIER 50HS-036---301- Btu/hr 11957 11g57 1196 1620 ( 0 14773 1.43 21125 54616 HEATING 38 F PEAK (Aug 5pm} 47 CFM} 1 COINCIDENT 50 % COOLING SENSIBLE LATENT 83 F Btu/hr 15681 15681 1568 202 0 0 17452 1.21 21116 28122 68 F Btu/hr 15'}6 1596 220 1816 8623 If Line 3-C > Line 3-B, Explain: ___________________ _ FAN POWER CONSUMPTION No. Efficiency Peak Conv Peak Supply Fan Description Sys BHP Motor Drive HP Fact Watts CFM -------------·------------------------------------------ Supply Fan 1 X 0.50 I [0.70 X 1.00] = 0.71 X 746 = 533 1250 ---------------- Totals 0.71 533 1250 FAN POWER DEMAND 533 watts/ 1250 cfm = 0.426 watts/cfm MECHANICAL SIZING AND FAN POWER MECH-2 page 16 of 25 --------------------------------------·------------------------------------Project ?fame: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 -----------------· --------------------.,------------------------------------ SIZING AND EQUIPMENT SELECTION HVAC System Name: Heating System Name: Cooling System Name: System Multiplier: Peak Load Method: Relative Humidity: 1. DESIGN CONDITIONS FOR Carlsbad 2. SIZING ZONES SERVED BY SYSTEM PEAK .---- East Offices Z2 (Jan 12am)- TOTAL ZONE LOAD Duct Gains & Losses: Ventilation: ( ~eturn Air Lighting Gain supply/Return Fan Gain: 95 CFM)- TOTAL SYSTEM LOAD 3. SELECTION A. Safe·ty/Warmup Factor B. Maximum Adjusted Load C. Installed Equipme-n·t Capacity HP-2 (Z2) CARRIER 50HS-036---301- Btu/hr 10202 10202 102-0 3266 ( 0 14488 1.43 20718 5461'6 HEATING 38 F PEAK (Aug Noon)- 95 CFM) 1 COINCIDENT 50 % COOLING SENSIBLE LATENT 83 F Btu/hr 15614 15614 1561 276 -0 0 17451 1.21 21116 28062 68 F Btu/hr 2600 2600 448 3048 89·90 If Line 3-C > Line 3-B, Explain: ___________________ _ FAN POWER CONSUMPTION Fan Description --------------------,· Supply Fan No. Sys BHP 1 X 0.50 / Efficiency Motor Drive --·--------- [0. 70 x 1.0-0] Totals Peak HP ----- = 0.71 ----- 0.71 Conv Peak Supply Fact Watts CFM ----------- X 746 = 533 1250 ----------- 533 1250 FAN POWER DEMAND 533 watts/ 1250 cfm = 0.426 watts/cfm M~CHANICAL SIZING AND FAN POWER ------·---.--------------MECH-2 page· 17 of 25· :Date: 9/3/1997 Proj-ect Name-: Wayne fo·ster Ente·rtainment Docu~entation: Henry Razouk I I :coMPLY 24 User 3268 SJ;ZING AN·D· EQUIPMENT SELECTION HVA-C System Name: Heating-System Name: -Cooling System Name: System Multip·lie·r: Peak L·oa-d· Method: Relative-Humidity: 1. DESIGN -CONDITIONS FOR Carlsbad 2. SIZING ZON·ES SERVED· BY SYS·TEM PEAK CON-FERENCE Z3 {Jan 12am)· TOTAL ZON·E LOAD· Duct Gains & Losses: Ventilation: ( 176 CFM)· Return Air Lighting Gain Supp-ly/Re-turn Fan Gain: TOTAL SYSTEM LOAD· 3 . SELE:CTION A. Safety/Warmup· Factor B. Maximum Adjusted Load C. Installed Equipment Capacity ---·.------------------------------------ HP-3 {Z3) CARRIER 50-HS-024---30-1-· Btu/hr 6335· 6335· 634 6·0·5·5· { O· 130-24 1.43 18624 36·410· 1 COINCIDENT 5-0· % COOLING HEATING SENS-IBLE LATENT 38 F PEAK (Aug 5pm) 176 CFM) 83 F Btu/hr 22632 22632 2263 75·7 0 0 25·65-2 1. 21 31039 18-477 68 F Btu/hr 5·242 5242 8·22 60-64 6534 If Line 3-C > Line 3-B, Explain: _____________ ___, _____ _ FAN· POWER CON-SUMPTION· No. Efficiency Peak Conv Peak Supp·ly Fan Des-er ipt ion Sys BHP Motor Drive HP Fact Watts CFM ------------------- Supply Fan 1 X ·O. 33 I [0.64 X 1.00] = 0.52 X 746 = 388 765 ----·---·-·-·- Totals 0.52 388 765 FAN POWER DEMAND 38·8 watts / 765 cf-m = 0.507 watts/cfm MECHAN-ICAL EQUIPMEN·T SUMMARY P-roj-ect Name-: Wayne-Foster Entertainment Documentation: Henry Razouk CENTRAL S·YS·TEM SUMMARY Sys No· System-N-ame System Type No MECH-3 page-18 of 25 :nate: 9/3-/1997 I I :coMPLY 24 User 3-268 Sys-Economizer Type 1 CARRIER 5-0HS-024---301-Packaged Heat Pu 1 No Economizer 2 CARRIER 50HS-036---3-01-Packaged Heat Pu 2 No E-conomiz-er CENTRAL SYSTEM RATINGS Sys-------Heating-------~--------------------------Cooling----------- No Type Output Aux KW EFF Type Output Sensi·ble EER SEER 1 Heat Pump 2 Heat Pump 23·600 35400 5.0 6.60 DX 7. 5 6. 80· DX 24000 35600 CENTRAL FAN SUMMARY------------Supply Fan----------- Sys Mtr Drv No Fan Type Motor Location CFM BHP Eff Eff 16800 8.60 10.00 24920 8.80 10.10 CFM Return Fan -- BHP Mtr Drv Eff ·Eff -----· -------------------------.;... ____ ---------------- 1 Constant Volume 2 Constant Volume ZONAL FAN SUMMARY Zone Name Draw-Through 765 0.33 64 100 Draw-Through 1250 0.50 70 100 ---------Zonal Fan------------ Mtr Drv No CFM BHP Eff Eff No CFM ----·------------· -----None None None Exhaust Fan Mtr BHP Eff Drv Eff MECHANICAL VENTILATION MECH-4 page 19 of 25 ----------------------·---------------------------------------,-------------:nate: 9/3/1997 I I Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :coMPLY 24 User 3268 ------· -------------------------------------------------------------------- VENTILATION SUMMARY BY ZONE Floor sqft CFM Dsg Min Zone ~ame T Occupancy Area /Occ /Occ CFM CFM ------------------------------------------------ Western Offices Zl * Office 626 100 7.5 47 47 East Offices Z2 * Office 1262 100 7.5 95 95 CONFERENCE Z3 * Convention/Con 351 15 7.5 176 176 ------ TOTALS 317 317 Tailored OA (T=*) requires supporting documentation on MECH-5, Tailored Ventilation and Process Loads Worksheet Tran sfer CFM HVAC SYSTEM HEATING & COOLING LOAD SUMMARY page 20 of 25 _:_----·---------------------------· ----------------------------------------Project Name: Wayn~ Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 user 3268 ---~---·-------------------------------------------------------------------- HVAC SYSTEM DESCRIPTION HVAC System Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: ZONES ON THIS SYSTEM Western Offices Zl PEAK (Jan 12am) TOTAL ZONE LOAD Duct Gains & Losses: Ventilation: ( Return Air Lighting Gain Supply/Return Fan Gain: 47 CFM) TOTAL SYSTEM LOAD SYSTEM OUTPUT AT DESIGN CONDITIONS AUXItIARY ELECTRIC HEAT MAIN HEATING & COOLING SYSTEM TOTAL SYSTEM OUTPUT HP-1 (Zl) CARRIER 50HS-036---301- 1 CA Daytime Fans COINCIDENT 50 % COOLING HEATING 11957 11957 1196 1620 ( PEAK (Aug 5pm) SENSIBLE LATENT 0 25598 29018 54616 47 CFM) 15681 15681 1568 202 0 0 17452 28122 28122 1596 1596 220 1816 8623 8623 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable m?trgin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final eq1J.ipment selection should notE;! that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. HVAC SYSTEM HEATING & CObLING LOAD SUMMARY Project Name: Wayne Foster Entertainment Documentation: Henry Razouk page 21 of 25 :Date: 9/3/1997 I I :coMPLY 24 user 3268 ---·-·--------------------------·.------------------------------------------ HVAC SYSTEM DESCRIPTION HVAC System Name: Heatin_g System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: ZONES ON THIS SYSTEM -----------------------PEAK East Offices Z2 (Jan 12am) TOTAL ZONE LOAD Duct Gains & Losses: Ventilation: ( 95 CFM) Return Air Lighting Gain Supply/Return Fan Gain: TOTAL SYSTEM LOAD SYSTEM OUTPUT AT DESIGN CONDITIONS AUXILIARY ELECTRIC HEAT MAIN HE·ATING & COOLING SYSTEM TOTAL SYSTEM OUTPUT HEATING -----~- 10202 ------- 10202 1020 3266 0 ------- 14488 25598 29018 546l6 HP-2 (Z2) CARRIER 50HS-036---301- 1 CA Daytime Fans COINCIDENT 50 % COOLING PEAK (Aug Noon) ( 95 CFM) SENSIBLE -------- 15614 -------- 15614 1561 276 0 0 -------- 17451 28062 28062 LATENT ------ 2600 ------ 2600 448 ------ 3048 8990 8990 NOTE: The TOTAL SYSTEM LOAD shown represents the m1n1mum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-tip capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. HVAC SYSTEM HEATING & COOLING LOAD SUMMARY Project Name: Wayne Foster Entertainment Documentation: Henry Razouk . . page 22 of 25 :Date: 9/3/1997 I I :coMPLY 24 User 3268 --------------------------------------------------------------------------- HVAC SYSTEM DESCRiPTION HVAC System Name: Heating System Name: Cooling System Name: System Multiplier: Fan Schedule: Peak Load Method: Relative Humidity: ZONES ON 1HIS SYSTEM --------,--------------CONFERENCE Z3 PEAK (Jan 12am) TOTAL ZONE LOAD Duct Gains & Losses: Ventilation: ( 176 CFM) Return Air Lighting Gain Supply/Return Fan Gain: TOTAL SYSTEM LOAD SYSTEM OUTPUT AT DESIGN CONDITIONS AUXILIARY ELECTRIC HEAT MAIN HEATING & COOLING SYSTEM TOTAL SYSTEM OUTPUT HEATING -------- 6335 ------- 6335 634 6055 0 ------- 13024 17065 19345 36410 HP-3 (Z3) CARRIER 50HS-024---301- 1 Undefined COINCIDENT 50 % COOLING PEAK (Aug 5pm) ( 176 CFM) SENSIBLE -------- 22632 -------- 22632 2263 757 0 0 -------- 25652 18477 18477 LATENT ------ 5242 ------ 5242 822 ------ 6064 6534 6534 NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment which will heat or cool this zone during the design conditions indicated. These numbers include no safety factor, and the HVAC contractor should oversize by a reasonable margin to account for variations in weather conditions and the pick-up capacity required to bring the zone to temper- ature as a result of a setback thermostat. Those responsible for final equipment selection should note that Sensible and Latent Cooling Loads are indicated to allow for accurate comparison with manufacturer's output data. ZONE HEATING & COOLING LOAD SUMMARY page 23 of 25 ---------,----------------------------·------------------------------------Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 user 3268 -·--·---------------------------------------------------------------------- SUMMARY OF PEAK HOUR LOADS FOR ZONE ZO~E Name: DESIGN CONDITIONS -----------------. Peak Hour: Indoor Conditions: Outdoor Conditions: LOAD COMPONENT Quantity ____ , --________ , _____ ------------Wall Conduction 349~0 sqft Window Conduction 179.0 sqft Door Conduction 0.0 sq:f:t Roof Conduction 626.0 sqft Skylight Conduction 0.0 sqft Floor Conduction 0 .. 0 sqft Slab Conduction Q.O sqft Interior Conduction. 0.0 sqft Infiltration 0.0 AC/hr Solar Gain 179.0 sqft Lighting 1404.0 watts Receptacle 31.3 watts Process 0.0 watts Occupants 6.3 occs ZONE LOADS Western Offices Zl COOLING HEATING SENSIBLE LATENT --------------------- Jan 12am Aug 5pm 70 F DB 78 F DB 50 % RH 38 F DB 82 F DB 67 F WB Btu/hr Btu/hr Btu/hr --------------------- 8397 3809 2864 230 0 0 696 391 0 0 0 0 0 0 0 0 0 0 0 6134 0 3415 0 107 0 0 0 1596 1596 --------------------- 11957 15681 1596 Heating AirFlow: Cooling AirFlow: 11957 Btu/hr/ [1.08 x 35 F DeltaT)] = 15681 Btu/hr/ [1.08 x 23 F DeltaT)] = 317 cfm 632 cfm ZONE HEATING & COOLING LOAD SUMMARY Project Na~e: Wayne Foster Entertainment Documentation: Henry Razouk page 24 of 25 : D_ate: 9/3/1997 I I :coMPLY 24 User 3268 ----------------------------------------"---------------------------------- SUMMARY OF PEAK HOUR LOADS FOR ZONE ZONE Name: DESIGN CONDITIONS --------------------Peak Hour: Indoor Conditions: Outdoor Conditions: LOAD COMPONENT ---------------------. . Wall Conduction Window Conduction Door Conduction Roof Conduction Skylight Conduction Floor Conduction Slab Conduction Interior Conduction .Infiltration Solar Gain Lighting Receptacle Process Occupants Heating AirFlow: Cooling AirFlow: East Offices Z2 COOLING HEATING SENSIBLE LATENT --------------------- Jan 12am Aug Noon 70 F DB 78 F DB 50 % RH 38 F DB 81 F DB 67 F WB Quantity Btu/hr Btu/hr Btu/hr --------------~------------------ 743.0 sqft 7391 2520 0.0 sqft 0 0 60.0 sqft 743 310 1262.0 sqft 2068 2526 0.0 sqft 0 0 0.0 sqft 0 0 0.0 sqft 0 0 0.0 sqft 0 0 0.0 AC/hr 0 0 0.0 sqft 0 0 2076.0 watts 0 6888 63.1 watts 0 215 o.o watts 0 0 12.6 occs 0 3155 2600 --------------------- ZONE LOADS 10202 15614 2600 10202 Btu/hr/ [1.08 x 15614 Btu/hr/ [1.08 ~ 35 F DeltaT)] = 23 F DeltaT)] = 270 cfrn 630 cfrn ZONE HEATING & COOLING LOAD SUMMARY page 25 of 25 ,------------------------------,-------------------------------------------Project Name: Wayne Foster Entertainment Documentation: Henry Razouk :Date: 9/3/1997 I I :coMPLY 24 User 3268 ----.---------------------------------------------------------------------- SUMMARY OF P~AK HOUR LOADS FOR ZONE ZONE Name: DESIGN CONDITIONS --------------------Peak Hour: Indoor Conditions: Outdoor Conditions: LOAD COMPONENT ---------------------Wall Condqction Window Conduction Door Conduction Roof Conduction Skylight Conduction Floor Conduction Slab Conduction Interior Conduction Infiltration Solar Gain Lighting Receptacle Process Occupants Heating AirFlow: Cooling AirFlow: CONFERENCE Z3 COOLING HEATING SENSIBLE LATENT --------------------- Jan 12am Aug 5pm 70 F DB 78 F DB 50 % RH 38 F DB 82 F DB 67 F WB Quantity Btu/hr Btu/hr Btu/hr --------------------------------- 0.0 sqft 0 0 3ff0. 0 sqft 5760 488 0.0 sqft 0 0 351.0 sqft 575 338 0.0 sqft 0 0 0.0 sqft 0 0 0.0 sqft 0 0 o.o sqft 0 0 0.0 AC/hr 0 0 360.0 sqft 0 13453 540.0 watts 0 2396 17.6 watts 0 60 o.o watts 0 0 23.4 occs 0 5897 5242 --------------------- ZONE LOADS 6335 22632 5242 6335 Btu/hr/ [1.08 x 22632 Btu/hr/ [1.08 x 35 F DeltaT)] = 23 F DeltaT)] = 168 cfm 913 cfm