HomeMy WebLinkAbout1940 KELLOGG AVE; ; CB972503; PermitB U I L D I N G P E R M I T
:l,.0/17/97 13:02
Permit No: ·cB972503
·Projeet No: A9703184.
Page· i of 1
Suite:
Development No:
Job Addre:ss: 1940 KELLOGG AV '" Permit Type: COMMERCIAL TENANT ·IMPROVEMENT 0375 10/17 i9T iQ.~M'1l· 02 2440-00 Parcel No: 212-170-03-00 Lot#:
vaiuation: 59,514 Construction ,Type: NEW
:tSSUED
09/04/97
Occupancy Group:
pescription: CTI 2289 SF
Ref erende# :-Status·:
Applied:
''
Appl/Ownr: MARSCH RICHARD
1821 VIA QUARTO
760
Apr/Issue;
Entered By:
724-8827
10/17/97
JM
OCEANSIDE, CA 9 2 0 56 ,,.~-_:, --~·-·-·--.
·***. Fees Required *** ,,,..,.,,,-·*** Fe~ollected & Credits *'**
---· ---____________________ .....,.,..,./ -----.,.,,.r:"J __ ,,,.:~~-----. ~'--------_,. ---------"• -----, . /. /' :r I' I""-.. -~ .· Fees: 2, 791,.ilO --..\ C:.-\ \../ , ti\ C) ,...
Adjustrnents: //. Qq~-, )~ "-..:JVTofa.l' sledi s: , 00
Total Fees: 2,791.0~..// Tota±J/&yqi~ts'\· 351.00
I --'/~~ &:i~)i,~)pu~: 2, 4.40. 0-0
. Fee description / ,,., // JpY\(\(\c-i:'iJ~'i ts ~J/Un\t Ext fee Data
------------------------•. ----,. ---------.. 4,! ~---. -----.-,..-----------------------
·Building Permit / fr.,,,,~, / '~;;,' "-::::::::::-.:::::::::....~____;:;.:;,, \ ~ \ 4.60. 00
Plan Check (': "· --.) / ~-·, .. ~-~·-=--:,.,··/ . \ t~.-\ 299. oo.
strong Motion Fee :,.:../! n / ··-.. ~ . ...-Al' 1--)1 I· 13. oo
Enter "Y" to Autoc~l~:t'j/c~nse T~'~ _. -. . -~~ f ~".::/ 1· 1083. 00 Y
Enter ':rraffic Impa~t, Fee \ <:.>,.._ 1 }J~' >( , 777Ji· ./.iJ'i'\~ J · 770. 00
*,BUILDING TOTAL \ .. ' . \c:.::.·-~\,"-,.. . ·( / . _ 2625.00
Enter "Y" ~or P~umbfng Issul"-Eee7~~ ,__/, ~ , ·/ .· ._ · / 20·. O·O Y
Each Plumbing Fixtu:t:e or Tra:p / ~ ~ 3 . 7. 0-9 21. o·o
* PLUMBING TOTAL , '.' "',, ~--· lf\52 / · -,,. .,, · 48. 0-0
Enter 11 Y11 for Electric\!~~µ~ ff1r ~---7-_J~_.;,, '\\.~ V 10. 00 y
Remodel/Alter Per AMP "\,_ '-""\/// /? {2· ~(o)2Gttt\ . 25 · 50. oo :* ELECTRICAL TOTAL . "·< <<) ,:/ / (5 ( ()) ,-~~ \) . . . . 6 0 . 0-0
Enter .;.Y' for Mechanical Issu~Fee·> ~,.) ~ 15.00 Y'
Install Furn/Ducts/Heat Pumps· ·-....... __ >.: _____ .~-9·. 00 36. 00
Each Exhaust Fan > 1 6.5~ 6,50 * MECHANICAL TOTAL 58.00
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsba9, CA 92009 (619} 438-1161
FOR OFFICE USE ONLY
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr., Carlsbad CA 92009
(760) 438-1161
PLAN CHECK NO. Cf7L5<;_3
EST. VAL. -· _5...,..:Z~'i~L~'i-------~:-----
rr,::-~cfiNFQRMA'ffi»C -· : « , ::;:· -. .,__ ... · :> · -810 #~ s,
Address (includeBldg/Suite #) ~usiness Name (at this address)' ·
J .....
Legal Description Lot No. · Subdivision Name/Number 4ft No: Phase No.
·Assessor's Parcel # Existing Use-Proposed Use
Total # of units
Sbf;tU,,L
#of Stories C?{ne6.--~~-
#·of Bedrooms # of Bathrooms
Name =c==""'-Address -~--City · State/Zip Telephone # Fax #
~JJT~~t~t~R;;;~70.\)j:~~~=qt·,.QW;i~~-~0:-<~:,~~~
Name Address · · · · City · State/Zip Telephone #
14•. "".;eRoPER:rv:oWNER' · · ~-. • •·• · .. • -·-....... ':. ~ , · ,., · .. ··. : .. ,.: . .-·: .. ···., ." ........ --. .-.. ----···:· ., .. ,,/ "',:·;·.,.,. :<,._. ·'>-,~-...r-. :·· .. :··. -<"·· ::-,,,_'f:: ·,.,:.,~,,, .-·~·-· ·· ... ,· .·· .-:. ·_, t:;;i;,;i;ii;-"~~1fi;fiiiiiiliiiiij;;2f5fie,. . ef£71$t;;i4~7;r~ifi;-'ij{217~<1-1:fiiiii2
Name ===~ Address City _..,.,.,,_,__ S.tate/Zip Telephone#
~;'.°';.;.,¢Ji.t1.T.8AOT.OJ'l.,;:t;.'Q9..M?~lllX:t,1~Mi..;.:.,, .. ' _,s.,,··,; .4h;,i.,..~;, ,:0.,~.:.. ;:, , . ;-.,,:w.~·,, ,c ,;:: ..... ·.:.:.;~:.;;, ~,,,,;.~ .::-:.,,,, ;,.;,3;?:J;~~:::..-~:;;:::;.~.:::,:;~,.;~.1.~:,~~' ... :, ;;;;fff';';Z;;.-;., •.. , :;-:0~ '1
(Sec. 7031.5 Business and Professions Code: Any City or County which re):luires a. perrnit to cpnstruct, alter, improve, ·demolish ·or repair any structure, prior to· its
issuance, also requires the applicant for such permit to file a signed statement that he is . .licensed pursuant to the provisions of tre <;:ontractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
·exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a:civil penalty of noh':lore than five hundred d_ollars [$5001).
Pd:G Cavsr . .:i..os? 4/tEsrMt,.cr,fz/.,F ~~S&M C,,,f--'t'Joot 76o-7J9-7-/-f--7
Name Address -City State/Zip Telephone#
State License # 7 f 4:;S" b 8 License Class B City Business License # --------
Designer Name Acldress City_. State/Zip Telephone
State License# _________ _
!§ .. ~ · -WO.BK~'.Cqr.,~NS'A:ff.Q_~ ~~~~~~~~-,H:~-:::~~~:-:,,:...~ , :L:':-'.,~::::~3;~£:.~Z~0.~!S:-¥~~~~f:ri.:~:;:,~;~
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the followi_ng declarations:
D I have and will maintain a certificate of consent to self-insure for workers' compensation as.provided by Section 3700 of. the Labor Code, for the performance
of the work for which this permit is issued.
~ I have and will maintain workers' compensation, as required by Section 3700 of the l:abor Code, for the·,performance of·the work for which this permit is
ifs~ed. My worker's c?::!n insurance ~arrier and policy number are: /. ~
Insurance Company ~ Fu.-,,,_cr Policy No. .J-:J: '1-91 / '1 CJ ,:.J Expiration Date /-/ , f 8 . .
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOl:l:ARS ($100] OR·l:ESS)
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manher so as
to become subject to the Workers' Compensation Laws of California. ·
WARNING: Failure to secure workers' compensation coverage is unlawfui, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($10 00), i a ditio the ost of compensation, damages as provided for in Section 3706 of the L!lbor .code, interest and attorney's fees.
SIGNATURE_~=...JC:::i.:::......3...<--1,~!,,:f,...£'-'l~r..,______________ DATE /0-1''7 -f 7
£2;;.,,,'..'...QW.~gf!Ji!lUJ~QJ;{l-;'Q.E.C~8'&l!D...N~~, .. ' ,.,:,,. ~:~ ,, ..:_,:_ __ ...;.;;:~;:,,;, :_',;,.'' >· . '..:.:i._,;:.:,,_,..,;;,;;.,. •. ,: ... · :. -"' .: , • .'.:•:t~2£.:l:.:.,:;,::"::,;,:" .21;...•~':';,,':'2: :'.;, ~de.: :t::.~:;;:;;::i;::;,,:-'
I hereby affirm that I am exempt·from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employeE)s with wages as their sol!! compensation, will do the· work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor''s License Law does not apply to an owner ·of property who builds or improves there-on, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, howevE!r, the building or improvement is
~old'within,one·year of completion, the owner-builder will have the burden c:>f proving that he did not build or improve for. the purpose of sale). -
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7.044, Business arid Professions Code: The
,Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed,
pursuant to the Contractor's License Law).
D I am exempt under Section ______ Business and-Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted_ with the following person (firm) to provide the proposed construction (include name I address /-phone number/ contractors license number):
4; I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number/ contractors license number>=----~-----------------------------------------
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name./ address/ phone number/ type
of work): _________ -'----------------------'-------------,--------------
PROPERTY OWNER SIGNATURE ________________ --'--~~--DATE ________ _
t9..Qfif~~'[tfils:~~§tt.PK!PtiNP.N~~~{PJ,.QIN~f.~)l)~"";YV~: '!..::sT.!;F;:::::·:·::,,:·~~-n?:.'..il!;E:':\2L;}{'i3'Ji,s0r>::::z::~i~-;;7,::-:;3~3r:::~i!~.ZJ
Is the applicant or future !)uilcling occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534iof the Presley-Tanner Hazardous Substance Account Act? 0 YES ·o NO
.Is the applicant or future building occupant required to obtain a permit from-the air polh,1ti_on control district o'r air quality management district? q YES D NO.
Is the facility to be constructed within 1,000 feet of the. outer boundary of a schopl site'? · D YES O NO
IFANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED'·UNLESS THE,APPLfCANT HAS MET OR IS MEETING THE
REQUIREMENTS-OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION c·oNTROL DISTRICT. ·~~~~ .
~~j:9,Qfl{tBYOIIPJt1,,ffi.pJ~11~~'(~~~=~?-N~-~,,;;:~ 2 _,,;,-__,,-:,, -.:::~ ~:~~0l~5~GI77:~:3~~;*~;;,~~: ;i,: :::';Si~~::;~;~:fu~~--;~:-4~~; q,;c .. ,i:~:;T~-1~?~-~-~y;
I hereby affirm that there is a construction lending age_ncy for the performance of the work for :,vhich this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state -that the above information is correct and that the information-on the plans is accurate. I agree to comply with all
City ordinances and State laws. relating to building construction, I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN c·oNSEQUENCE OF THE GRANTIN'G OF THiS PERMIT. -
-OSHA: An OSHA permit is required for excavations over 5'0" deep and d·~mciiition or construction of structu~es over 3 stories in height.
EXPIRATION: Every permit issued by the· Building Official under the provisions of-this Code shall expire by limitation and become null and void if the building or
work-authorized by such permit is riot com'meRced wi n 3 5 from the date of such permit or-if the building or work authorized by such permit is suspended
or abandoned at any time after the k is com e f · tt·of 80 days (Section 106.4.4 Uniform BuildinQ Code).
APPLICANT'S SIGNATURE L__,:::~~~.2.~~LJ~~:__~==::::=-----~----DATE _2_-_f,,__·~f,,__7 ______ _
WHITE: File YEL:LOW: Appiit:ant PINK: Finance
10/17/97 13:01
Page. 1 of 1
Job Address: 1940 KELLOGG AV
SEWER
Permit Type: SEWER -OFF.ICE/WAREHOUSE
Parcel No: 212-170-03-00
Description: CTI 2289 SF·
: WAREHOUSE TO OFFICE
P E R M I T
Suite:··
Permit No~ SE970:l,.67,
Bldg PlanCk#: CB972503
0375 10/17/97 0001 01
c..:PRMT
'St!:ttUS:
App.lied:
02
. 1528!'00
ISSUED
09/29/97
10/17/97
Permite-e: MARSCH RICHARD 760
Apr/Issue:
724_'.8827· . · Expired.:
1821 VIA QUARTO
·ocEANSIDE, CA 92056
: -• ·, r r n r ,· .. : ·-~' r.f\.. ' ,-ff ,, , :i
t "1 ...... .. -"cl -.J u u u J V 'lh ......
CITY OF CARLSBAD·
·· 'Prer;:,ared By:
2075 Las Falmas Dr., Carlsbad, CA.''92009 (619) 438-ll(jl
MAM.
PERMIT# CB972503
DESCRIPTION: CTI 2289 SF
CITY OF CARLSBAD ·
INSPECTI-ON REQUEST
FOR 01/13/98 INSPECTOR AREA TP
PLANCK# CB972503
OCC GRP
TYPE: CTI
JOB ADDRESS: 1940 KELLOGG AV
APPLICANT: MARSCH RICHARD
CONTRACTOR:
OWNER:
REMARKS: C/GARTH/ 619 /9 69-·054 7
SPECIAL INSTRUCT: AM PLEASE
TOTAL '11IME:
--RELATED PERMITS--PERMIT#
WM970029
SE970.167
TYPE
WMETER
swow
STE:
CONSTR. TYPE NEW
LOT:
PHONE: 760 724-8827
PHONE: ~ PHONE:
INSPECTOR . -...,,,,,_ _________ _
STATUS
ISSUED
ISSUED
CD LVL DESCRIPTION ACT COMMENTS
19 ST Final structural /11!_ ______ _
29 PL Fi:p.al Plumbing
39 EL Final Electrical
49 ME Final Mechanical t---
--------~---------
--------'---------------,--------~-------
***** INSPECTION HISTORY*****
DATE DESCRIPTION
010698 Final Combo
123197 Final Combo
122397 Frame/Steel/Bolting/Welding
1223·97 Rough Electric
122397 Rough/Ducts/Dampers
122297 Rough Combo
112597 Interior Lath/Drywali
112497 Interior Lath/Drywall
112197 Insulation
i12097 Rough/Topout
112097 Rough/Ducts/Dampers
112097 Rough ·Electric
112097 Frame/Steel/Bolting/Welding
111997 Rough Combo
111897 Rough Combo
102997 Underground/Under Floor
ACT co
co
AP
AP
AP
NR
AP co
AP
AP
AP
AP
AP co
NR
PA
INSP
TP
TP
PS
PS
PS
PS
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
COMMENTS
SEE CORR LIST ATCH
PART INSP/SEE CARD
T-BAR
T-BAR
T-BAR
NR FORT-BAR/ND TO COMP ELEC
NOT COMP
EXHST DUCTS
WALLS
WATER TEST,NEED A/B U.G. REV.
FINAL' BUILDING INSPECTION
DEPT: BUILDING ENGINEERING <~· PLANNING U/M WATER
PLAN CHECK#: CB972503
PERMIT#: CB972503
PROJECT NAME: CTI 2289 SF
ADDRESS: 1940 KELLOGG AV
CONTACT PERSON/PHONE#: C/GARY/967-2400
SEWER DIST: CA . WATER DIST: CA
INSP~ BY: ~--..Lo,/,.-a.......,
INSPECTED
BY:
INSPEC-TED
BY':
===..-
COMMENTS:
DATE I l INSPECTED: 1 ~ 9B
DATE
INSPECTED:
DATE
INSPECTED:
APPROVED
APPROVED
DATE: 12/31/97
PERMIT TYPE: CTI
DISAPPROVED
DISAPPROVED
DISAPPROVED
.
. . . from/ // IJ l'J;ffJIP//7c)' -
, 7 . /
_ ~, 7tv-72/--/ft"7 I . ----
EsGil Corporation
Professional Pftm. !l{.eview 'Engineers
DATE: 9/29/97
JURISDICTION: Carlsbad
Pl.AN CHECK NO.: 97-2503
PROJECT ADDRESS: 1940 Kellog ~t.
PROJECT NAME: Wayne Foster, Inc. TI
SET: II
~ .. ANT.
JURI .
CJ N REVIEWER
CJ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
• The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
• Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: )
Mail Telephone Fax In Person
• RiMARKS: 1. New sheets A-2, A-4 & M-1 at the city must b n porated into the city set of
plans. 2. lr1clude in the city set of plans the clouded notes fo ' · on sheet A-5 of the plans from
EsGil. 3. City is to verify that the access from the handicap d parking to the tenant space
complies with the current access standards.
By: Chuck Mendenhall
_ Esgil Corporation
D GA D CM D EJ D PC 9/22/97
Enclosures:
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576
EsGil Corporation·
Professionaf Pftm !l(eview 'Engineers
DATE: 9/16/97
JURISDICTION: Carlsbad
PLAN CHECK NO.: 97-2503
PROJECT ADDRESS: 1940 Kellog St.
PROJECT NAME: Wayne Foster, Inc., TI
SET:I
D APPLICANT ~
~EVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved an·d checked by building department
staff. ·
D The plans transmitted herewith have significant deficiencies id~ntified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
• The check list transmitted he·rewith. is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy_of the .check list is enclosed for the jurisdiction to forward to the applicant
contact person.
• The applicant's copy of the check list has been sent to:
Richard Marsch
1825 Via Quarto, Oceanside, CA 92056
• Esgil Corporation staff did not·advise the applicant (except by mail) that the plan check has
been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
· Person contacted: Telephone#:
Date contacted: (by: )
Mail Telephone Fax In Person
D REMARKS:
By: C)luck Mendenhall
E:sgil Corporation
D GA D CM D EJ D ~c 9/9/97
Fax#:
Enclosures:
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576
Carlsbad 97-2503
9/16/97
PLAN Rl:VIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 97-2503
OCCUPANCY: B
TYPE OF 'CONSTRUCTION: VN
ALLOWABLE FLOOR AREA:
SPRINKLERS?:
REMARKS:
DATE PLANS RECSIVED BY
JURISDICTION: 9/4/97
JURISDICTION: Carlsbad
USE: Office
ACTUAL AREA: 2289
STORIES:
HEIGHT:
OCCUPANT LOAD: 42
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 9/9/97
DATE INITIAL PLAN REVIEW
COMPLETED: 9/ 16/97 .
PLAN REVIEWER: Chuck Mendenhall
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building
Code, Uniform Plumbing Code,. Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled. This plan
review is based on regulations enforced by the Building Department. You may have other
corrections based on laws and ordinances enforced by the Planning Department, Engineering
Department, Fire Department or other departments. Clearance from those departments may be
requited prior to the is·suance of a building permit.
Code sections cited are based on the 1994 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
·1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck proces~. please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet .number, specification section, etc.
Be sure to enclose the marked up list when you submit the ·revised. plans .
.LIST NO. 40, TENANT IMRROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tiforw.dot
Carlsbad 97-2503
9/16/97
1. Please make all corrections on the original tracings, as requested in the
correction list.
Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one.of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to
the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA
92009, (619) 438-1161. The City will route the plans to EsGil Corporation and
the Carlsbad Planning, Engineering_ and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619)
560-1468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning,
Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete. ·
2. In areas where the o_ccupant load exceeds 30 two exits are required. See UBC.
Table 10-A. The occupant load of the tenant space with conference rm is 42.
Provide two exits from this space.
3. Exits should have a minimum separation of one-half the maximum overall
diagonal dimension of the building or area served. Section 1003.3.
4. Exit signs are required whenever two exits are required. Show all required exit
sign locations. Section 1013.1.
5. Corridors serving 30 or more occupants shall have walls and ceilings of
one-hour construction. UBC 1005.
6. One-hour fire-rated corridors shall -have interior door openings protected by
tight-fitting smoke and draft control assemblies rated 20 minutes, except
openings in interior·walls of exterior exit balconies. Doors shall be maintained
self-closing or be automatic closing by action of a smoke detector per Section
713.2. Doors shall be gasketed to provide a smoke and draft seal where the
door meets the stop on sides and top. Section 1005.8.1.
7. Window openings in the ·1 HR corridor shall be protected by fixed glazing listed
and labeled for a fire-protection rating of at least 3/4-hour. Section 713.9.
8. If a room with an exhaust fan has a door opening into a rated corridor, show how
makeup air will be provided to the room. The door cannot be undercut, nor can a
louver in the door be provided. Section 1005.8.1. This applies to the bath rms
opening into the corridor.
Carlsbad 97-2503
9/'16/97
9. Clearly show Where the non-rated corridor system terminates and a rated
corridor system commences.
10. Show rated corridors, lobbies, reception or foyers cross-hatched on the floor
plans.
11. Smoke/Fire dampers shall be installed per Section 713.1 0 at all ducted or
unducted air -openings at penetrations of:
a) The fire-resistive construction of corridors.
12. Provide a complete architectural section of the corridor, or exterior exit balcony,
showing all fire-resistive materials and details of construction for all floors, walls,
ceiling and all penetrations. Section 1005. 7.
13. Specify lever-type hardware for passage doors on floors accessible to the
disabled. Section 2-3304, Title 24.
14. Show on the plans the required wall and ceiling insulation as required by the
energy design. ·
• MECHANICAL
15. Note on the plans that the mechanical ventilation in all rooms capable of
supplying outside air at a minimum rate. of 15 cubic feet per minute per
occupant. UBC, Section 1202.2.1 ·
16. Detail disposal of main condensate drainage from air conditioning units. (UMC
Section 310)
• CITY OF CARLS8AD SUPPLEMENT
17. Roof mounted equipment must be screened and roof penetrations should be
minimized (City Policy 80-6).
18. No wiring is permitted on the roof of a building and wiring on the exterior of a
building requires approval by the Building_ Official. (City Policy)
19: All roof-mounted equipment shall be concealed from view. Provide structural
detailing for the screening.
DEPARTMENT OF STATE ARCHITECT NON RESIDENTIAL
TITLE 24 DISABLED 'ACCESS REQUIREMENTS
• REMODELS, ADDITIONS AND REPAIRS
1. When alterations, structural repairs or modifications or additions are made to an existing
building, that builging, or portion of the building affected is required to comply with all of the
Carlsbad 97-2503
9/16/97
requirements for new buildings, per Section 1134B.2. These requirements apply only to the area
of specific alteration, repair or addition and shall include:
a) A primary entrance to the building and the primary path of travel to the area in
question, and include the following items which serve the area in question:
• SITE PLAN REQUIREMENTS
2. Clearly show that the site development the location of the disabled accessible parking and the
path of travel to the tenant space.
To speed up the review process, note on this list (or a copy) where each correction
,item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them
and Where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
· indicate:
Yes CJ No CJ
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you.
Carlsbad 97-2503
9/16/97
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsb~d PLAN CHECK NO.: 97-2503
PREPARED BY: Chuck Menden,hall DATE: 9/16/97
BUILDING ADDRESS: 1940 Kellog St.
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN
BU'!LDING PORtlON BUILDING AREA VALUATION VALUE
(ft. 2) MULTIPLIER ($)
Tl 2289 26 59,514
-
Air Conditioning
Fire Sprinklers
TOTAL VALUE 59,514
• 1991 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ 459.50
• 1991 UBC Plan Check Fee D Plan Check Fee by ordinance: $ 298.68
Type of Review: • Complete Review D Structural Only D Hourly
D Repetitive Fee Applicable D Other:
Esgil Plan Review Fee: $ 238.94
Comments:
Sheet 1 of 1
macvalue.doc 5196
-
·-
City of Carlsbad
M#ih·ii,t441ih•i•l4·SIUl,t4h•
BUILDING PLANCHECK CHECKLIST
·DATE: 9°-aq-_q_7. PLANCHECKNO.: CBCl7d503
BUILDING ADDRESS: /14-0 f0. I/_ ~co ~ _
PROJECT DESCRIPTION: ;;/ J, RCJ '.f;;{ ~"pj ~~
ASSESSOR'S 'PARCEL NUMBER: _________ EST. VAt:. :
ENGINEERING DEPARTMENT
APPROVAL . DENIAL
The item you have submitted for review has been
approvec!. · The approval is based on plans,
inf9rmation and/or specifications provided in your
submittal; therefore any changes to these items after
this date-, including field modifications, must be
reviewed by this office to insure c:9ntinued
conformance with-applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report · can r~sult in ·
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
Please see the attached report of deficiencies
marked with D. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
.specifications to this office for review.
By: Date:
'By: --------Date:
By: --------Date:
FOR OFFICIAL USE ONLY
ENGINEERING:AUTHO~IZATiON:-0 I -~UILDING'PERMIT: -· -/17 --9 ~ 7· a7 -' , ----/ . : _-_ _ _ . : , .-· .Date: ___ --' _ _,;_ __ __,L..
ATTACHMENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sew~r Fee Information Sheet
ENGINEERING DEPT. CONTACT PERSON
Name: Michele Masterson
City of Carlsbad
Address: 2075 Las Palmas Dr., Carlsbad, CA 92009
Phone: _(619) 438-1161, ext. 4315
CFD INFORMATION
_Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
A-4
\\LASPALMASISYS\LIBRARY\ENGIWORD\DOCS\CHKLST\Bulkfing Plancheck Cklst BPD001 Form MM,doc .,.
Rev,o9103'~075 Las Palmas Dr.• Car.lsbad, CA 92009-~ 576 • (619) 438-1161 • FAX (619) 438-0894
( .
..
A ST.1/';ND.I di ~
lo D
BUILDING PLANCHECK CHECKLIST
.SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
2. Show on site plan:
A Drainage Patterns .
1. Building pad surface drainage must maintain a minimum slope of one
.percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
0 . 3. Include on title $heet:
D
A. Site adQress
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer· permits showing Square footage of different uses (manufacturing,
. warehouse, office, etc.) previously approved.
EXISTING PgRMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
4a. Project does not comply with the following Engineering Conditions of approval for
Project No. _____________________________ _
4b. All c~mditiolis are in compliance. Date: __________ _
~~::~~:tSYS\LIB~RYIENG\WORD\OOCSICHKLST1Bulld1ng Plancheck Cklst BP0001 Fonn MM.dqc _-2
0 0 0
0 0 0
BUILDING PLANCHECK CHECKLIST
. DEDICATION REQUIREMENTS
5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a v1;1lue at or exceeding $ ______ , pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required 8$ follows: _________________ _
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 ½" x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completec;f by: ___________ _ Date: -----
IMPROVEMENT REQUIREMENTS
6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ _______ , pursuant to Carlsbad Municipal Code
Section 18.40.040 ..
Public improvements requited as follows: _____________ _
Attai;;hed please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the·
apprc;>priate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
checklist must be· submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed bf ___________ _ Date: ____ _
6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1.8.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $ _______ so
we may prepare the necessary Future Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future pub_lic improvements required as follows:
\\LASPALMASISYS\LIBRARYIENG\WORD\DOCS\CHKLST\Building Plancheck Cklst BR0001"Fonn MM.doc
Rev. 09/03/97 3
1 st.r . 2ndJ' 3rdJ'
0 0 0
0
0 0
0 0
0
0
0
0
0
aUILDING PLANCHECK CHECKLIST
6c. E_nclosed please find your Future Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
. 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
·improvements found adjacent to building site must be. repaired to the satisfaction
of the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal -Code.
7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export). Write
· "No Grading" on plot plan if none is required.
7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must· be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by: Date:
7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not teqtJii"ed.)
7d.No Grading Permit required.
7~.lf grading i$ not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMltS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tieing
into public storm drain, sewer and water utilities.
Right-of-Way permit required for:
I\LASPALMASl~YS\LIBRARY\ENG\WORD\oocs1cHKLST\Buikfing Plancheck Cklst BP0001 Fonn MM.doc • 4
Rev:09/03/97
i:J
i:J [j
BUILDING PLANCHECK CHECKLIST
9. A SEWER PERMIT is required concurrent with the building permit issuance. The
fee is noted in the fees section on the following page.
i:J 10. INDUSTRIALWASTE PERMIT If your .facility is located-in the City of Carlsbad
i:J
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for
assistance.
Industrial Waste ,permit accepted by:
Date:
11. NPDES PERMIT
Complies with the City's r~quirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occur7st. .
12. ~equired fees are attached
i:J No fees required
/
13. Additional Comments:
l\lASPALMAS\SYS\LIBRARY\ENGIWORD\DOCSICHKLST\B4ildmg Plancheck Cklst BPOJ)01 Fof!TI MM.doc 5
Rev. 09/03/97 ·
'·
_ ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
~· Estimate based on unconfirmed information from applicant. I Calculation based on building plancheck plan submittal.
Address: I q + 0 f5 e /lc,@'J t4-u e__. Bldg. Permit No. C 8 q Zd ;So -2
Prepared by(/7/.l(}\__ Date: 1/4-1 /q 7 Checked by: ____ Date: ____ _
EDU CALCULATIONS: tist type's and sq1,1are foot8J}es for all uses.
· · le)are lfot1se . . .;<. .;l 89
Types of Use:c/o t) f{l'e ,e Sq. Ft._/~: _____ _
o t-f--re..-e --~,;)_, ~ q ~ /~ () 0
tu,,u,-t._fttY&t.S-e. -:;l. :J....t"J· 7 5 000
ADT .CALCULATIONS: List types and square footages for all uses.
' Wctre kt,u s-e. . <J ---> 8-c:,
Types of Use: <Y'c, o:-h';E'.t'C e___ Sq. Ft./.~ -~'-'---c:7\ __ -_t_
ef-f'tc.-e_ -,;i<yjo-,,o. .
(,uq_r-e)i.c,u...-s "?-.-000 D
FEES REQUIRED:
/. ;l. 7
EDU'·s: C::.6 41,'). -----
0 8 I
46
ADT's: L /I>
35
PUBLIC FACILITIES FEE REQUIRED: D YES D NO (See Building Department for amount)
WITHIN CFO: m--1ES (no bridge & thoroughfare fee, reduced Traffic Impact Fee) D NO
~K-IN-LIEU FEE PARK AREA: __ _
/ FEE/UNIT:
lzr 2. TRAFFIC IMPACT FEE
ADT's/UNITS: s 5
~OGE .AND THOROUGHFARE FEE
ADT's/UNITS: .
~AGILITIES MANA~EME!')T FEE
X NO. UNITS: __ _
X FEE/ADT:
X FEE/ADT: ___ _
ZONE: --~-
=$
=$
/ UNIT/SQ.FT.: X FEE/SQ.FT./UNIT: ___ _ =$
~ 5. SEWER FEE
PERMIT No.S{?~ q 70 / 6 7
x FEE/EDU: / g I 0
DRAIN~GE BASIN: 5 F
EDU's: 0;, 8 [
BENEFIT AREA: C-v
EDU's: e:,_ '3 f ~ DRAINAGE FEES PLDA. ___ _
ACRES: X
¥-;~WER LATERAL ($2,500)
X FEE/EDU: 7 "'
HIGH ___ /LOW __ _
FEE/AC: __ _
=$
=$
=$
=$
77()
e-
o-.
I) f.ftp I:,
. C:, ;;L
0
C) -
TOTAL OF ABOVE FEES*:$ d,t ~ q 2
* NOTE: This calculation sheet is NOT a complete list ~f all fees which may be due.
Dedic~tions and Improvements may also be required with Building Permits.
P:\DOCS\MISFORMS\BP0002.FRM REV 01/22/97
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB CJ J~ 5C> 3> -DATE __ 1__,)~~_,_i;/2_7 ___ 7 _______ _
ADDRESS / cf {j:1) ked, C-· . . u
RESIDENTIAL
RESIDENTIAL ADDiTION MINOR
( < $1 0,000.0O)
-~--/ cJ u iD~ ~rePt~&owrJ
~~,~ . C
PLAZA CAMINO REAL
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
-ENGINEER _____________ DATE ______ _
C:\WP5"1 \FILES\BLOG.FRM Rev 11 /15/90
.
City of Carlsbad ·· 97304
Fire Department • B1;1reau of Prevention
. Plan Review: Requirements Category: Building Plan Check ,
Date of Report: Tuesday, September 16, 1997 Reviewed by:_%-·-~=-"-%f&=--.· ,.=,,.___"'_
Contact Name Richard Marsch·
Address 6640 Lusk Bl Suite 205C
City, State San Diego CA 92121
Bldg. Dept. No. CB97-250·3 Planning No.
Job Name Wayne Foster Ent
Job Address _1_9_40_K_el_lo~gg _____________ _ Ste. or Bldg. No. ____ _
181 Approved -The item you have submitted for review has been approved. The approval is
based on plaAs; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure
to comply with instructions in thi$ report can result in suspension of permit to
construct or install improvements.
D Disapproved -Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.
For Fire Department Use Only
Review 1st. __ _ 2nd __ _ 3rd. __ _
Other Agency ID
CFO Job# __ 97_3_0_4 __ File# __ ~_
2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121
TITLE 24 REPORT FOR:
Wayne Foster Entertainment
1540 Kellog Drive
Carlsbad, CA 92009
PROJECT DESIGNER:
Steve White
6351 Corte Del Abeto, Suite A100
C~rlsbaQ, CA 92009
(760) 931-1130
REPORT PREPARED BY:
Henry Razouk, PE
Henry Razouk
3291 Celi-nda Drive
Carlsbad, CA 92008
('760) 434-3433
Job Number: 97-1008
Date: 9/3/1997
The COMPLY 24 computer program has been used to perform the calculations
summarized in this compliance report. Th:i;s. program has approval and is
authorized by the California Energy Commission for use with both the
Residential and Nonresidential Buildirig Energy Efficiency Standards.
This program developed by Gabel Dodd/EnergySoft, llc (415) 883-5900.
Table Of Contents for Title 24 Report
Cover Page .................................. -· . . . . . . . . . . . . . . . . . . . . . . . 1
Table of Contents . . . • . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Form ENV-1
Form ENV-2
Form L'i'G-1
Form LTG-2
Form MECH-1
Form MECH-2
Envelope Cert if ica te of Compl ianc·e . . . . . . . . . . . . . . . . . . . . . . . 3
Prescriptive Envelope Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Lighting Certificate of Compliance ....................... 9
Prescriptive Lighting Compliance Summary ................. 11
Mechanical Certificate of Compliance .................... 12
Prescriptive Mechanical Summary ......................... 15
Form MECH-3 Mechanical Equipment Sum~qry ............................. 18
Form MECH-4 Mechanical Ventilation .................................. 19
HVAC $ystem ioads Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Zone Loads Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3
CERTIFICATE OF COMPLIANCE -Envelope (part 1 of 2) ENV-1 page 3 of 25 ------.--------------------------------------------------------------------Project Name: Wayne Foster Entertainment
Address: 1540 Kellog Drj.ve
Carlsbad, CA 92009
Envelope
Designer: Steve White
Documentation: Henry Razouk
Date: 9/3/1997
Building Permit No
Checked by/ Date
COMPLY 24 User 3268 -----------------·--------, ------------------------------------------------
GENERAL INFORMATION
Date of Plans:______ Building Conditioned Floor Area: 2239 sf
Building Type: Nonresidential Climate Zone: 7
Phase of Construction: O New Construction O Addition O Alteration
Method of Envelope Compliance: Prescriptive -Overall Envelope
STATEMENT OF COMPLIANCE
This Certificate of. Compliance lists the·Building features and performance
specifications needed to comply with Title 24, Parts 1 and 6 of the Calif-
ornia Code of Regulations. This certificate applies only to building
envelope requirements.
The documentation preparer hereby certifies that the documentation is
accurate and complete.
DOCUMENTATION AUTHOR
Henry Razouk, PE
(760) 434-3433 (Signature) (Date)
The Principal Envelope Designer hereby certifies that the proposed build-
ing design represented in this set of construction documents is consistent
with the other compliance forms and worksheets, with the specifications,
and with any other calculations submitted with this permit application.
The proposed building has been designed to meet the envelope requirements
contained in sec-tions 110, 116 through 118, and 140, 142, 143 or 149 of
Title 24, Part 6, Chapter 1.
Please check one:
O I hereby affir~ that I am eligible under the provisions of Division 3
of the Business and Professions Code to sign this document as the
person responsible for its preparation; and that I am a civil engineer
or architect.
O I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Section 5537.2 of the Business and
Professions Code to sign this document as the person responsible for
its preparation; and that I am a licensed contractor preparing docu-
ments for work that I have contracted to perform.
O I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Section ____ of the _______ _
Code to sign this document as the person responsible for its
preparation; and for the following reason: ______________ _
PRINCIPAL ENVELOPE DESIGNER
Steve White
( 76O~) 9-31-1130 (Signature) (Lie. #) (Date)
ENVELOPE MANDATORY MEASURES
Indicate location on plans .of Note Block for Mandatory Measures:
CERTIFICATE OF COMPLIANCE -Envelope (part 2 of 2) ENV-1 page 4 of 25 --------------------------------------------· ------------------------------P~oject Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 user 3268 ----·--------------------------.-------------------------------------------
OPAQUE SURFACES
Assembly Name ________________ , _____ _
R-11 Metal Stud Wall
R-19 Roof (R.19.2x8.16)
R-30 Roof(R.30.2x12.16)
6 ;, Concrete Wall
Solid Wood Door
FENtSTRATION Frame
Orient Panes Type ------------------
Front (S) 2 Metal
Left (W) 2 Metal
Left (W) 2 Metal
Const
Type Location/Comments
Note to
Field
---,-----------------------------Metal
Wood
Wood
None
None
Exterior Shade -------------------.---None
None
None
OH
N
N
N
Glazing Type
I
I
I
I
I
I
I
I
I
I
------------------------
Gray Lite (N)
Gray Lite (N)
Gray Lite (N)
OVERALL ENVELOPE METHOD (part 1 of 4) ENV-2 page 5 of 25
-----------------------------,---------------------------------------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 ----------------------------------------------------------------------------
WINDOW AREA TEST
A. Display Perimeter 0.0 ft X 6 ft = 0.0 sf Display Area
B. Gros-s Exterior Wall Area 1691.0 sf X 0.40 = 676.4 sf 40% Area
c. Gross Exterior Wall Area 1691.0 sf X 0.10 = 169.1 sf Min Std Area
D. Enter Larger of A or B 676.4 sf Max Std Area
E. Enter Proposed Window Area 539.0 sf Proposed Area
If E i~ greater than Dor less than C, proceed to
for window area adjustment. If not, go to part 2
the next
of 4.
calculation
1. If Eis greater than D:
D. Maximum Standard Area ---------------------
N/A I
2. If Eis less than C:
c. Minimum s·tandard Area ----------------, -------
N/A I
Window
E. Proposed Area . Adjustment Factor
N/A
E. Proposed Area
N/A
=
=
N/A
Window
Adjustment Factor
N/A
---------------------------------------------------------------------------
SKYLIGHT AREA TEST
Atrium Height
0.0 ft
If Height< 55 ft If Height>= 55 ft
Standard= 5% ---------+----------Standard= 10%
I
I
V
A. Gross Exterior Roof Area i239.0 sf X 0.05 = 112.0 sf Standard Area
B. Enter Proposed Skylight Area 0.0 sf Proposed Area
If the Proposed Skylight Area is greater than the Standard Skylight Area,
proceed to the next calculation fo~ the skylight area adjustment. If not
got to part 2 of 4.
1. If Proposed Skylight Area> Standard Skylight Area:
Standard Skylight Area Proposed Skiiight Area --------------------------------------------
N/A I N/A =
Skylight
Adjustment Factor
N/A
OVERALL ENVELOPE METHOD (part 2 of 4) ENV-2 page 6 of 25
-· --------------------------------· --.-------------------------------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 ------------------·-------------------------·------------------------------
OVERALL HEAT LOSS
PROPOSED Adj. STANDARD
Ass~mJ:>ly Name Area HC U-Val UxA Area U-Val UxA ---------------------------------------------------------6 II Concrete Wall 163.0 14.0 0.752 122.6 163.0 0.430 70.1
6 II Concrete Wall 54.0 14.0 0.752 40.6 54.0 0.430 23.2
6 ti Concrete Wall 132.0 14.0 0.752 99.2 132.0 0.430 56.8
R-30 Roof{R.30.2~12.16) 626.0 2.7 0. 03-5 21.7 626.0 0.078 48.8
Gray Lite (N) 63.0 N/A 0.500 31.5 63.0 1.230 77.5
Gray Lite (N) 58.0 N/A 0.500 29.0 58.0 1.230 71.3
Gray Lite (N) 58.0 N/A 0.500 29.0 58.0 1.230 71.3
6 ti Concrete Wall 161.0 14.0 0.752 121.1 161.0 0.430 69.2
R-11 Metal Stud Wall 71.0 2.6 0.189 13.4 71.0 0.189 13.4
R-11 Metal Stud Wall 511.0 2.6 0.189 96.5 511.0 0.189 96.6
R--19 Roof (R.19.2x8.16) 1262.0 2.3 0.051 64.6 1262.0 0.078 98.4
R-19 Roof (R.19.2x:8.16) 351.0 2.3 -0. 051 18.0 351.0 0.078 27.4
Gray Lite (N) 117.0 N/A 0.500 58.5 117.0 1.230 143.9
Gray Lite (N) 243.0 N/A 0.500 121.5 243.0 1.230 298.9 ------------
Total 867.2 Total 1166.9
** OVERALL HEAT LOSS COMPLIES PROPOSED UA <= STANDARD UA **
OVERALL ENVELOPE METHOD (part 3 of 4) ENV-2 page 7 of 25 ---------------------------------------------------------------------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 ----.. ______________ " _____________________ . ---------------------------------
OVERALL HEAT GAIN
PROPOSED STANDARD
Glazing WF Area SC H V OHF Total Area RSHG Total -------------------------------------------
West 1.34 63.0 0.40 33.8 63 .. 0 0.71 59.9
·west 1.34 58.0 0.40 31.1 58.0 0.71 55.2
West 1.34 58.0 0.40 31.1 58.0 0.71 55.2
South 1.31 117.0 0.40 61.3 117.0 0.71 108.8
West 1.34 243.0 0.40 130.2 243.0 0.71 231.2 -------------
Total 287.5 Total 510.3
** OVERALL HEAT GAIN COMPLIES PROPOSED HG<= STANDARD HG**
OVERALL ENVELOPE METHOD (part 4 of 4) ENV-2 page 8 of 25 ________ , _______________ ·--------.----.------------------------------------
Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 -----,.------------------------------------·--------------------------------
Window Area Adjustment Calculations
Adjusted
Gross Door Window Adjust Window Wall
Wall N~me Dir Area Area Area Factor Area Area ----------·-------.----------------------------------------
North Wall N 163.0 0.0 1.0000 0.0 163.0
South WALL s 54.0 0.0 1.0000 0.0 54.0
West WALL w 311.0 179.0 1.-0000 179.0 132.0
North WALL (EXT) N 161.0 0.0 1.0000 0.0 161.0
North (INT) N 91.0 20.0 0.0 1.0000 o.o 71.0
East WALL (INT) E 551.0 40.0 0.0 1.0000 0.0 511.0
South WALL s 117.0 117.0 1.0000 117.0 0.0
West WALL w 243.0 243.0 1.0000 243.0 0.0 -----------------------------
TOTALS 1691.0 60.0 539.0 539.0 1092.0
Skylight Area Adjustment Calculations
Adjusted
Gross Skylt Adjust Skylt Roof
Roo.f Name Dir Area Area Factor Area Area ----------------------------------------------------
Roof H 626.0 0.0 0.0000 0.0 626.0
Roof H 1262.0 0.0 0.0000 0.0 1262.0
Roof H. 351.0 0.0 0.0000 0.0 351.0 -----------------------
TOTALS 2239.0 0.0 0.0 2239.0
CERTIFICATE OF COMPLIANCE -Lighting (part 1 of 2) LTG-1 page 9 of 25 -----------------~---------------------------------------------------------Project Name: Wayne Foster Entertainment
Address~ 1540 Kellog Drive
Carlsbad, CA 92009
Lighting
Designer:
Documentation: Henry Razouk
:Date: 9/3/1997
I ·----------:Building Permit No
I ·----------: checked by/ Date
I
I
:coMPLY 24 User 3268
-------------·----------------------------·-----· wl ------------------------
GENERAL INFORMATION
Date of Plans: Building Conditioned Floor Area: 2239 sf
Building Type: Nonresidential Climate Zone: 7
Phase of Construction: O New Construction O Addition O Alteration
Method of Lighting Compliance: Prescriptive
STATEMENT OF COMPLIANCE
This c·ertificate of Compliance lists the Building features and performance
specifications needed to comply with Title 24, Parts 1 and 6 of the Calif-
ornia Code of Regulations. This certificate applies only to building
lighting requirements.
'
·The documentation preparer hereby certifies that the documentation is
accurate and complete.
DOCUMENTATION AUTHOR
Henry Razouk, PE
(760) 434-3433 (Signature) (Date)
The Principal Lighting Designer hereby certifies that the proposed build-
ing design ~epresented in this set of construction documents is consistent
with the other compliance forms and worksheets, with the specifications,
and with any other calculations submitted with this permit application.
The proposed building has been designed to meet the lighting requirements
contained in sections 110, 119, 13.0 through 132 and 146 or 149.
Please check one:
o I hereby affirm that I am eligible under the provisions of Division 3
of the Business and P.rofessions Code to sign this document as the
person·responsible for its preparation; and that I am a civil engineer
electrical engineer or a~chitect.
O I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Section 5537.2 of the Business and
Professions Code to sign this document as the person responsible for
its preparation; and that I am a licensed contractor preparing docu-
ments for work that I have contracted to perform.
o I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Section ____ of the
Code to Sign this document as the person responsible for its
preparation; and for the following reason: ______________ _
PRINCIPAL LIGHTING DESIGNER
(S.rgnature) (Lie. #) (Date)
LIGHTING MANDATORY MEASURES
Indica.te location on plans of No-te Block for Mandatory Measures:
CERTIFICATE OF COMPLIANCE -Lighting (part 2 of 2) LTG-1 page 10 of 25 -----------.--------------------------------------.------------------------Project Name: Wayne. Foster Entertainment
Documentation: Henry Razouk
INSTALLED LIGHTING ·SCHEDULE
No of
Name Lamp Type Lamps -----------------------
A Fluorescent 3
MANDATORY AUTOMATIC CONTROLS
Control
Watts/ Ballast
Lamp Type -----------------34 Standard
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268
Ballasts/ No of Note to
Luminaire Fixt. Field
. --------------------
1.5 13
Control Location ID Control Type Zone Controlled
Note to
Field
CONTROLS FOR CREDIT
Control
Control Location ID Control Type Zone ·Controlled
Note to
Field
LIGHTING COMPLIANCE SUMMARY LTG-2 page 11 of 25 --------------------------------------_" __________ ·------------------------
Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
ACTUAL LIGHTING POWER
Name Description
No of
Lumin
:Date: 9/3/1997
I
I
:coMPLY 24 user 3268
Watts Total
per Default Watts --------------------------------------------------------------------
A 48" T-12 Low Watt /3 Lamp (Tandem) 13 108.0 1404.0
SubTotal 1404
Less Control Credits (LTG-3) O
Total Proposed Watts 1404
* If not CEC Default value, please provide supporting documentation.
ALLOWED LIGHTING POWER BY ZONE
Zone Name
Western Offices Zl
East Offices Z2
CONFERENCE Z3
Occqpancy
Office
Office
Convention/Conference
TOTALS
Floor
Area -----
626
1262
351 -----
2239
Allowed
LPD
(w/sf) ------
1.600
1.600
1.600 ------
1.600
Total Tailored
(watts) (watts) --------------
1002 0
2019 0
562 0
--------------
3582 0
* Note: Tailored Allotment requires supporting documentation on form LTG-4.
CERTIFICATE OF COMPtIANCE -Mechanical (part 1 of 3) MECH-1 page 12 of 25 -----:_--------------------------------------------------------------------'Project Name: Wayne Foster Entertainment
Address: 1540 Kellog Drive
Carlsbad, CA 92009
Mechanical
Designer: West-Air Mechanical
Documen·tation: Henry Razouk
Date: 9/3/1997
Building Permit No
Checked by/ Date
COMPLY 24 User 3268 -------------------------------------------··-------------------------------
GENERAL INFORMATION
Date of Plans:______ auilding conditioned Floor Area: 2239 sf
Building Type: Nonresidential Climate Zone: 7
Phase of Construction: O New Construction O Add-ition O Alteration
Method of Mechanical Compliance: Prescriptive
Proof of Envelope Compliance: O Previous Permit O Compliance Attached
STATEMENT OF COMPLIANCE
This Certificate of Compliance lists the Building features and performance
specifications needed to comply with Title 24, Parts 1 and 6 of the Calif-
ornia Code of Regulations. This certificate applies only to building
mechanical requirements.
The documentation preparer hereby .certifies that the documentation is
accurate and compl~te.
DOCUMENTATION AUTHOR
Henry Razouk, PE
(760) 434-3433 (Signature) (Date)
The Principal Mechanical Designer hereby certifies that the proposed build-
ing design represented in this set of construction documents is consistent
with the other compliance forms and worksheets, with the specifications,
and with any other calculations submitted with this permit application.
The proposed Building has been designed to meet the mechanical requirements
contained in sections 110 through 115, 120 through 124, 140 through 142,
144 and 145. ·
Please check one:
O I hereby affirm that I am eligible under the provisions of Division 3
of the Business and Professions Code to sign this document as the
person responsible for its preparation; and that I am a civil engineer
mechanical engineer or architect.
O I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Section 5537.2 of the Business and
Professions Code to sign this document as the person responsible for
its preparation; and that I am a licensed contractor preparing docu-
ments for work. that I have c·ontracted to perform.
O I affirm that I am eligible under the exemption to Division 3 of the
Business and Professions Code by Section---,----of the
Code to sign this document as the person responsible for its
preparation; and for the following reason: ______________ _
PRINCIPAL MECHANICAL DESIGNER
West~Air Mechanical
( 760) 529-8787
MECHANICAL MANDATORY MEASURES
(Signature) (Lie. #) (Date)
Indicate location on plans of Note Block for Mandatory Measures:
CERTIFICATE OF COMPLIANCE -Mechanical (part 2 of 3) MECH-1 page 13 of 25 ·----------------------------------------------·---------------------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 -----------------------------------·---------------------------------------
SYSTEM FEATURES
Zone Name
Time Control
Setback Control
#of Isolation Zones
HP Thermostat
Electric Heat
Fan Control
VAV Min Pos.i tion
Simul. Heat/Cool
Heat Supply Reset
Cool Supply Reset
Ventilation
OA Damper Control
Economizer Type
Outdoor Air CFM
Heat·Equip Type
Make & Model No.
Cool Equip 'J_'ype
Make and Model
Zone Name
Time. Control
Setb.ack Control
#of Isolation Zones
HP Thermostat
Electric Heat
Fan Control
VAV Min Position
Simul. Heat/Cool
Heat Supply Reset
Cool Supply Reset
Ventilation
OA Damper Control
Economizer Type
Outdoor Air CFM
Heat Equip Type
Make & Model No.
Cool Equip Type
Make and Model
Code Tables
Time Control
S:Prog Switch
O:Occ Sensor
M:Man Timer
HP-1 (Zl.) 5 '
Setback
n/a
Yes
7.5 KW
Constant Volume
n/a
n/a
Constant Temp
Constant Temp c
No Economizer
47
HP-2 (Z2) s
Setback
n/a
Yes
7.5 KW
Consta,nt Volume
n/a
n/a
Constant Temp
Constant Temp
C
N CqE . o conom1zer
95
Heat Pump Heat Pump
CARRIER 50HS~036---301-CARRIER SOHS-036---301-
DX DX
HP--3 (Z3)
5
Setback
n/a
Yes
5.0 KW
Constant Volume
n/a
n/a
Constant Temp
Constant Temp
C
No Economizer
176
Heat Pump
CARRIER SOHS-024---301-
DX
Ventilation
B:Air Balance
C:OA Cert.
M:OA Measure
D:Demand Cont
N:Na,tural
OA Damper
A:Auto
G:Gravity
Note to
Field
CERTIFICATE OF COMPLIANCE -Mechanical (part 3 of 3) MECH-1 page 14 of 25
----------------------------------·----------------------------------------Projec,t Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 user 3268 ---------------------------------------------------------------------------
DUCT INSULATION
System Name Type Duct Location
Duct Tape Insul Note to
Allowed R-Val Field --------------------------------------------------------------------
CARRIER SOHS-036---301-Heating Ducts in Attic
Cooling Ducts in Attic
CARRIER SOIJS-036---301-Heating Ducts in Attic
Cooling Ducts in Attic
CARRIER SOHS-024---301-Heating Ducts in Attic
Cooling Ducts in Attic
PI'PE INSULATION
System Name Pipe Type ----------------------------------Do~estic Hot Water
Insu·1
Required
y / N
NOTES TO FIELD -For Building Department Use Only
l~: f IN flt I N
r!)I N
4.2
4.2
4.2
4.2
4.2
4.2
Note to
Field
MECHANICAL SIZlNG AND FAN POWER MECH-2 page 15 of 25
------------------------------------------·--------------'-----------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razou~
:Date: '}/3/1997
I
I
:coMPLY 24 User 3268 _____ ,_ ·-------------------------------------------------------------------
SIZING AND EQUIPMENT SELECTION
HVAC System Name:
Heating System Name:
Cooling System Name:
System ~ultiplier:
Peak Load Method:
Relative Humidity:
1. DESIGN CONDITIONS FOR Carlsbad
2. SIZING
ZONES SERVED BY SYSTEM
Western Offices Z1
PEAK
(Jan 12am}
TOTAL ZONE LOAD
Duct Gains & Losses:
Ventilation: (
Return Air Lighting Gain
Supply/Return Fan Gain:
47 CFM)
TOTAL SYSTEM LOAD
3. SELECTION
A. Safety/Warmup Factor
B. Maximum Adjusted Load
C. Installed Equipment Capacity
HP-1 (Zl)
CARRIER 50HS-036---301-
Btu/hr
11957
11g57
1196
1620 (
0
14773
1.43
21125
54616
HEATING
38 F
PEAK
(Aug 5pm}
47 CFM}
1
COINCIDENT
50 %
COOLING
SENSIBLE LATENT
83 F
Btu/hr
15681
15681
1568
202
0
0
17452
1.21
21116
28122
68 F
Btu/hr
15'}6
1596
220
1816
8623
If Line 3-C > Line 3-B, Explain: ___________________ _
FAN POWER CONSUMPTION
No. Efficiency Peak Conv Peak Supply
Fan Description Sys BHP Motor Drive HP Fact Watts CFM -------------·------------------------------------------
Supply Fan 1 X 0.50 I [0.70 X 1.00] = 0.71 X 746 = 533 1250 ----------------
Totals 0.71 533 1250
FAN POWER DEMAND 533 watts/ 1250 cfm = 0.426 watts/cfm
MECHANICAL SIZING AND FAN POWER MECH-2 page 16 of 25 --------------------------------------·------------------------------------Project ?fame: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 -----------------· --------------------.,------------------------------------
SIZING AND EQUIPMENT SELECTION
HVAC System Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Peak Load Method:
Relative Humidity:
1. DESIGN CONDITIONS FOR Carlsbad
2. SIZING
ZONES SERVED BY SYSTEM PEAK .----
East Offices Z2 (Jan 12am)-
TOTAL ZONE LOAD
Duct Gains & Losses:
Ventilation: (
~eturn Air Lighting Gain
supply/Return Fan Gain:
95 CFM)-
TOTAL SYSTEM LOAD
3. SELECTION
A. Safe·ty/Warmup Factor
B. Maximum Adjusted Load
C. Installed Equipme-n·t Capacity
HP-2 (Z2)
CARRIER 50HS-036---301-
Btu/hr
10202
10202
102-0
3266 (
0
14488
1.43
20718
5461'6
HEATING
38 F
PEAK
(Aug Noon)-
95 CFM)
1
COINCIDENT
50 %
COOLING
SENSIBLE LATENT
83 F
Btu/hr
15614
15614
1561
276
-0
0
17451
1.21
21116
28062
68 F
Btu/hr
2600
2600
448
3048
89·90
If Line 3-C > Line 3-B, Explain: ___________________ _
FAN POWER CONSUMPTION
Fan Description --------------------,·
Supply Fan
No.
Sys BHP
1 X 0.50 /
Efficiency
Motor Drive
--·---------
[0. 70 x 1.0-0]
Totals
Peak
HP -----
= 0.71 -----
0.71
Conv Peak Supply
Fact Watts CFM
-----------
X 746 = 533 1250 -----------
533 1250
FAN POWER DEMAND 533 watts/ 1250 cfm = 0.426 watts/cfm
M~CHANICAL SIZING AND FAN POWER ------·---.--------------MECH-2 page· 17 of 25·
:Date: 9/3/1997 Proj-ect Name-: Wayne fo·ster Ente·rtainment
Docu~entation: Henry Razouk
I
I
:coMPLY 24 User 3268
SJ;ZING AN·D· EQUIPMENT SELECTION
HVA-C System Name:
Heating-System Name:
-Cooling System Name:
System Multip·lie·r:
Peak L·oa-d· Method:
Relative-Humidity:
1. DESIGN -CONDITIONS FOR Carlsbad
2. SIZING
ZON·ES SERVED· BY SYS·TEM PEAK
CON-FERENCE Z3 {Jan 12am)·
TOTAL ZON·E LOAD·
Duct Gains & Losses:
Ventilation: ( 176 CFM)·
Return Air Lighting Gain
Supp-ly/Re-turn Fan Gain:
TOTAL SYSTEM LOAD·
3 . SELE:CTION
A. Safety/Warmup· Factor
B. Maximum Adjusted Load
C. Installed Equipment Capacity
---·.------------------------------------
HP-3 {Z3)
CARRIER 50-HS-024---30-1-·
Btu/hr
6335·
6335·
634
6·0·5·5· {
O·
130-24
1.43
18624
36·410·
1
COINCIDENT
5-0· %
COOLING
HEATING SENS-IBLE LATENT
38 F
PEAK
(Aug 5pm)
176 CFM)
83 F
Btu/hr
22632
22632
2263
75·7
0
0
25·65-2
1. 21
31039
18-477
68 F
Btu/hr
5·242
5242
8·22
60-64
6534
If Line 3-C > Line 3-B, Explain: _____________ ___, _____ _
FAN· POWER CON-SUMPTION·
No. Efficiency Peak Conv Peak Supp·ly
Fan Des-er ipt ion Sys BHP Motor Drive HP Fact Watts CFM -------------------
Supply Fan 1 X ·O. 33 I [0.64 X 1.00] = 0.52 X 746 = 388 765 ----·---·-·-·-
Totals 0.52 388 765
FAN POWER DEMAND 38·8 watts / 765 cf-m = 0.507 watts/cfm
MECHAN-ICAL EQUIPMEN·T SUMMARY
P-roj-ect Name-: Wayne-Foster Entertainment
Documentation: Henry Razouk
CENTRAL S·YS·TEM SUMMARY
Sys
No· System-N-ame System Type
No
MECH-3 page-18 of 25
:nate: 9/3-/1997
I
I :coMPLY 24 User 3-268
Sys-Economizer Type
1 CARRIER 5-0HS-024---301-Packaged Heat Pu 1 No Economizer
2 CARRIER 50HS-036---3-01-Packaged Heat Pu 2 No E-conomiz-er
CENTRAL SYSTEM RATINGS
Sys-------Heating-------~--------------------------Cooling-----------
No Type Output Aux KW EFF Type Output Sensi·ble EER SEER
1 Heat Pump
2 Heat Pump
23·600
35400
5.0 6.60 DX
7. 5 6. 80· DX
24000
35600
CENTRAL FAN SUMMARY------------Supply Fan-----------
Sys Mtr Drv
No Fan Type Motor Location CFM BHP Eff Eff
16800 8.60 10.00
24920 8.80 10.10
CFM
Return Fan --
BHP
Mtr Drv
Eff ·Eff -----· -------------------------.;... ____ ----------------
1 Constant Volume
2 Constant Volume
ZONAL FAN SUMMARY
Zone Name
Draw-Through 765 0.33 64 100
Draw-Through 1250 0.50 70 100
---------Zonal Fan------------
Mtr Drv
No CFM BHP Eff Eff No CFM ----·------------· -----None
None
None
Exhaust Fan
Mtr
BHP Eff
Drv
Eff
MECHANICAL VENTILATION MECH-4 page 19 of 25 ----------------------·---------------------------------------,-------------:nate: 9/3/1997
I
I
Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk :coMPLY 24 User 3268
------· --------------------------------------------------------------------
VENTILATION SUMMARY BY ZONE
Floor sqft CFM Dsg Min
Zone ~ame T Occupancy Area /Occ /Occ CFM CFM ------------------------------------------------
Western Offices Zl * Office 626 100 7.5 47 47
East Offices Z2 * Office 1262 100 7.5 95 95
CONFERENCE Z3 * Convention/Con 351 15 7.5 176 176 ------
TOTALS 317 317
Tailored OA (T=*) requires supporting documentation on MECH-5, Tailored
Ventilation and Process Loads Worksheet
Tran
sfer
CFM
HVAC SYSTEM HEATING & COOLING LOAD SUMMARY page 20 of 25 _:_----·---------------------------· ----------------------------------------Project Name: Wayn~ Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 user 3268 ---~---·--------------------------------------------------------------------
HVAC SYSTEM DESCRIPTION
HVAC System Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Fan Schedule:
Peak Load Method:
Relative Humidity:
ZONES ON THIS SYSTEM
Western Offices Zl
PEAK
(Jan 12am)
TOTAL ZONE LOAD
Duct Gains & Losses:
Ventilation: (
Return Air Lighting Gain
Supply/Return Fan Gain:
47 CFM)
TOTAL SYSTEM LOAD
SYSTEM OUTPUT AT DESIGN CONDITIONS
AUXItIARY ELECTRIC HEAT
MAIN HEATING & COOLING SYSTEM
TOTAL SYSTEM OUTPUT
HP-1 (Zl)
CARRIER 50HS-036---301-
1
CA Daytime Fans
COINCIDENT
50 %
COOLING
HEATING
11957
11957
1196
1620 (
PEAK
(Aug 5pm)
SENSIBLE LATENT
0
25598
29018
54616
47 CFM)
15681
15681
1568
202
0
0
17452
28122
28122
1596
1596
220
1816
8623
8623
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable m?trgin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
eq1J.ipment selection should notE;! that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
HVAC SYSTEM HEATING & CObLING LOAD SUMMARY
Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
page 21 of 25
:Date: 9/3/1997
I
I
:coMPLY 24 user 3268 ---·-·--------------------------·.------------------------------------------
HVAC SYSTEM DESCRIPTION
HVAC System Name:
Heatin_g System Name:
Cooling System Name:
System Multiplier:
Fan Schedule:
Peak Load Method:
Relative Humidity:
ZONES ON THIS SYSTEM -----------------------PEAK
East Offices Z2 (Jan 12am)
TOTAL ZONE LOAD
Duct Gains & Losses:
Ventilation: ( 95 CFM)
Return Air Lighting Gain
Supply/Return Fan Gain:
TOTAL SYSTEM LOAD
SYSTEM OUTPUT AT DESIGN CONDITIONS
AUXILIARY ELECTRIC HEAT
MAIN HE·ATING & COOLING SYSTEM
TOTAL SYSTEM OUTPUT
HEATING -----~-
10202 -------
10202
1020
3266
0 -------
14488
25598
29018
546l6
HP-2 (Z2)
CARRIER 50HS-036---301-
1
CA Daytime Fans
COINCIDENT
50 %
COOLING
PEAK
(Aug Noon)
( 95 CFM)
SENSIBLE --------
15614 --------
15614
1561
276
0
0
--------
17451
28062
28062
LATENT ------
2600 ------
2600
448
------
3048
8990
8990
NOTE: The TOTAL SYSTEM LOAD shown represents the m1n1mum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-tip capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
HVAC SYSTEM HEATING & COOLING LOAD SUMMARY
Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk . .
page 22 of 25
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 ---------------------------------------------------------------------------
HVAC SYSTEM DESCRiPTION
HVAC System Name:
Heating System Name:
Cooling System Name:
System Multiplier:
Fan Schedule:
Peak Load Method:
Relative Humidity:
ZONES ON 1HIS SYSTEM --------,--------------CONFERENCE Z3
PEAK
(Jan 12am)
TOTAL ZONE LOAD
Duct Gains & Losses:
Ventilation: ( 176 CFM)
Return Air Lighting Gain
Supply/Return Fan Gain:
TOTAL SYSTEM LOAD
SYSTEM OUTPUT AT DESIGN CONDITIONS
AUXILIARY ELECTRIC HEAT
MAIN HEATING & COOLING SYSTEM
TOTAL SYSTEM OUTPUT
HEATING --------
6335 -------
6335
634
6055
0 -------
13024
17065
19345
36410
HP-3 (Z3)
CARRIER 50HS-024---301-
1
Undefined
COINCIDENT
50 %
COOLING
PEAK
(Aug 5pm)
( 176 CFM)
SENSIBLE --------
22632 --------
22632
2263
757
0
0 --------
25652
18477
18477
LATENT ------
5242 ------
5242
822
------
6064
6534
6534
NOTE: The TOTAL SYSTEM LOAD shown represents the minimum size equipment
which will heat or cool this zone during the design conditions indicated.
These numbers include no safety factor, and the HVAC contractor should
oversize by a reasonable margin to account for variations in weather
conditions and the pick-up capacity required to bring the zone to temper-
ature as a result of a setback thermostat. Those responsible for final
equipment selection should note that Sensible and Latent Cooling Loads are
indicated to allow for accurate comparison with manufacturer's output data.
ZONE HEATING & COOLING LOAD SUMMARY page 23 of 25 ---------,----------------------------·------------------------------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 user 3268
-·--·----------------------------------------------------------------------
SUMMARY OF PEAK HOUR LOADS FOR ZONE
ZO~E Name:
DESIGN CONDITIONS
-----------------.
Peak Hour:
Indoor Conditions:
Outdoor Conditions:
LOAD COMPONENT Quantity ____ , --________ , _____ ------------Wall Conduction 349~0 sqft
Window Conduction 179.0 sqft
Door Conduction 0.0 sq:f:t
Roof Conduction 626.0 sqft
Skylight Conduction 0.0 sqft
Floor Conduction 0 .. 0 sqft
Slab Conduction Q.O sqft
Interior Conduction. 0.0 sqft
Infiltration 0.0 AC/hr
Solar Gain 179.0 sqft
Lighting 1404.0 watts
Receptacle 31.3 watts
Process 0.0 watts
Occupants 6.3 occs
ZONE LOADS
Western Offices Zl
COOLING
HEATING SENSIBLE LATENT ---------------------
Jan 12am Aug 5pm
70 F DB 78 F DB 50 % RH
38 F DB 82 F DB 67 F WB
Btu/hr Btu/hr Btu/hr ---------------------
8397 3809
2864 230
0 0
696 391
0 0
0 0
0 0
0 0
0 0
0 6134
0 3415
0 107
0 0
0 1596 1596 ---------------------
11957 15681 1596
Heating AirFlow:
Cooling AirFlow:
11957 Btu/hr/ [1.08 x 35 F DeltaT)] =
15681 Btu/hr/ [1.08 x 23 F DeltaT)] =
317 cfm
632 cfm
ZONE HEATING & COOLING LOAD SUMMARY
Project Na~e: Wayne Foster Entertainment
Documentation: Henry Razouk
page 24 of 25
: D_ate: 9/3/1997
I
I :coMPLY 24 User 3268 ----------------------------------------"----------------------------------
SUMMARY OF PEAK HOUR LOADS FOR ZONE
ZONE Name:
DESIGN CONDITIONS --------------------Peak Hour:
Indoor Conditions:
Outdoor Conditions:
LOAD COMPONENT ---------------------. .
Wall Conduction
Window Conduction
Door Conduction
Roof Conduction
Skylight Conduction
Floor Conduction
Slab Conduction
Interior Conduction
.Infiltration
Solar Gain
Lighting
Receptacle
Process
Occupants
Heating AirFlow:
Cooling AirFlow:
East Offices Z2
COOLING
HEATING SENSIBLE LATENT ---------------------
Jan 12am Aug Noon
70 F DB 78 F DB 50 % RH
38 F DB 81 F DB 67 F WB
Quantity Btu/hr Btu/hr Btu/hr --------------~------------------
743.0 sqft 7391 2520
0.0 sqft 0 0
60.0 sqft 743 310
1262.0 sqft 2068 2526
0.0 sqft 0 0
0.0 sqft 0 0
0.0 sqft 0 0
0.0 sqft 0 0
0.0 AC/hr 0 0
0.0 sqft 0 0
2076.0 watts 0 6888
63.1 watts 0 215 o.o watts 0 0
12.6 occs 0 3155 2600 ---------------------
ZONE LOADS 10202 15614 2600
10202 Btu/hr/ [1.08 x
15614 Btu/hr/ [1.08 ~
35 F DeltaT)] =
23 F DeltaT)] =
270 cfrn
630 cfrn
ZONE HEATING & COOLING LOAD SUMMARY page 25 of 25 ,------------------------------,-------------------------------------------Project Name: Wayne Foster Entertainment
Documentation: Henry Razouk
:Date: 9/3/1997
I
I
:coMPLY 24 User 3268 ----.----------------------------------------------------------------------
SUMMARY OF P~AK HOUR LOADS FOR ZONE
ZONE Name:
DESIGN CONDITIONS --------------------Peak Hour:
Indoor Conditions:
Outdoor Conditions:
LOAD COMPONENT ---------------------Wall Condqction
Window Conduction
Door Conduction
Roof Conduction
Skylight Conduction
Floor Conduction
Slab Conduction
Interior Conduction
Infiltration
Solar Gain
Lighting
Receptacle
Process
Occupants
Heating AirFlow:
Cooling AirFlow:
CONFERENCE Z3
COOLING
HEATING SENSIBLE LATENT
---------------------
Jan 12am Aug 5pm
70 F DB 78 F DB 50 % RH
38 F DB 82 F DB 67 F WB
Quantity Btu/hr Btu/hr Btu/hr ---------------------------------
0.0 sqft 0 0
3ff0. 0 sqft 5760 488
0.0 sqft 0 0
351.0 sqft 575 338
0.0 sqft 0 0
0.0 sqft 0 0
0.0 sqft 0 0 o.o sqft 0 0
0.0 AC/hr 0 0
360.0 sqft 0 13453
540.0 watts 0 2396
17.6 watts 0 60 o.o watts 0 0
23.4 occs 0 5897 5242 ---------------------
ZONE LOADS 6335 22632 5242
6335 Btu/hr/ [1.08 x
22632 Btu/hr/ [1.08 x
35 F DeltaT)] =
23 F DeltaT)] =
168 cfm
913 cfm