Loading...
HomeMy WebLinkAbout1945 COBALT DR; ; CB063530; Permit02-06-2007 , Job Address Permit Type Parcel No Valuation Occupancy Group 02/06/2007 # Dwelling Units Bedrooms Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No CB063530 Building Inspection Request Line (760) 602-2725 1945 COBALT DRCBAD RESDNTL Sub Type SFD 2132901100 Lot# 74 $306,471 00 Construction Type VN Reference # CT 04-09 1 SFD 3 Structure Type 4 Bathrooms TRIESTE PL 2 2748SF LV, 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/96SF PATIO Status ISSUED Applied 12/18/2006 Entered By JMA Plan Approved Issued Inspect Area Orig PC# Plan Check* 02/06/2007 PC 06-35 PC 06-66 Applicant WARMINGTON HOMES 701 PALOMAR AIRPORT RD CARLSBAD CA 92011 931-4766 Owner WARMINGTON TRIESTE ASSOCIATES L P C/0 WARMINGTON HOMES CALIFORNIA 3090 PULLMAN ST #A COSTA MESA CA 92626 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $1,18412 Meter Size $0 00 Add'l Reel Water Con Fee $769 68 Meter Fee $0 00 SDCWA Fee ($61 57) CFD Payoff Fee $3065 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee $0 00 Housing InLieu Fee $3,389 00 Housing Credit Fee D5/8 Master Drainage Fee $0 00 Sewer Fee $0 00 Additional Fees TOTAL PERMIT FEES $000 $16000 $4,31300 $2,960 75 $5,577 77 $000 $000 $000 $720 00 $000 $000 $259 00 $6000 $7400 $000 $000 $000 $000 $000 $17900 $19,61540 Total Fees $19,615 40 Total Payments To Date $19,61540 Balance Due $000 Inspector FINAL APP Date VAL Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review, set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired CcV City of Carlsbad Final Building Inspection Dept Building Engineering Planning CMWD St Lite Fire Plan Check# PC 06-66 Date L_ Permit* CB063530 Permit Type Project Name TRIESTE PL 2 2748SF LV, 639SF Sub Type GAR/110SF DECK/138SF LOG/120SF PORCH/96SF PATI Address 1945 COBALT DR Lot 74 Contact Person KYLE Phone 7604271926 Sewer Dist LC Water Dist CA AUG -8 2007 08/08/2007 RESDNTL SFD Inspected By Goos. Inspected By Inspected By Date Inspected Date Inspected Date Inspected g>/l3/O7 Approved X Disapproved . Approved Approved Disapproved Disapproved Comments City of Carlsbad Bldg Inspection Request For 08/08/2007 Permit* CB063530 Title TRIESTE PL 2 2748SF LV, 639SF Description GAR/110SF DECK/138SF LOG/120SF PORCH/96SF PATIO Inspector Assignment MC Type RESDNTL Sub Type SFD Job Address 1945 COBALT DR Suite Lot 74 Location OWNER WARMINGTON TRIESTE ASSOCIATES L P Owner WARMINGTON TRIESTE ASSOCIATES L P Remarks Phone 7604271926 Inspector f/l Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By KYLE Entered By CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 06-35 Comments EMR ONLY INT BATH & SHOWER LATH Date 07/10/2007 06/05/2007 05/25/2007 05/24/2007 05/24/2007 05/24/2007 05/23/2007 05/21/2007 05/18/2007 05/16/2007 05/02/2007 04/23/2007 04/18/2007 Inspection History Description 39 Final Electrical 17 Interior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 23 Gas/Test/Repairs 82 Drywall/Ext Lath/Gas Test 16 Insulation 16 Insulation 84 Rough Combo 13 Shear Panels/HD's 15 Roof/Reroof 15 Roof/Reroof Act AP AP AP NR AP AP NR AP CA AP AP AP NR Insp MC MC MC MC MC MC MC MC PY MC MC MC MC PER CONTRACTOR AFTER STOP RE-CK TRUSS J1 PER CONTRACTOR AFTER STOP City of Carlsbad Bldg Inspection Request For 07/10/2007 PerrniW CB063530 Title TRIESTE PL 2 2748SF LV, 639SF Description GAR/110SF DECK/138SF LOG/120SF PORCH/96SF PATIO Inspector Assignment MC Sub Type SFD 1945 COBALT DR Lot Type RESDNTL Job Address Suite Lot 74 Location OWNER WARMINGTON TRIESTE ASSOCIATES L P Owner WARMINGTON TRIESTE ASSOCIATES L P Remarks EMR Phone 7604271926 Inspector Total Time Requested By KYLE Entered By CHRISTINE CD Description 39 Final Electrical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 06-35 Date 06/05/2007 05/25/2007 05/24/2007 05/24/2007 05/24/2007 05/23/2007 05/21/2007 05/18/2007 05/16/2007 05/02/2007 04/23/2007 04/18/2007 03/13/2007 03/02/2007 03/02/2007 03/06/2006 Inspection History Description 17 Interior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 23 Gas/Test/Repairs 82 Drywall/Ext Lath/Gas Test 16 Insulation 16 Insulation 84 Rough Combo 13 Shear Panels/HD's 15 Roof/Reroof 15 Roof/Reroof 81 Underground Combo 21 Underground/Under Floor 22 Sewer/Water Service 16 Insulation Act AP AP NR AP AP NR AP CA AP AP AP NR AP AP PA AP Insp MC MC MC MC MC MC MC PY MC MC MC MC MC MC MC RB Comments INT BATH & SHOWER LATH PER CONTRACTOR AFTER STOP RE-CK TRUSS J1 PER CONTRACTOR AFTER STOP RECEIVED PT & BLDG PLACEMENT REPORT BACK FLOW PREVENTER REQ City of Carlsbad Bldg Inspection Request For 03/13/2007 Permit* CB063530 Inspector Assignment MC Title TRIESTE PL 2 2748SF LV, 639SF Description GAR/110SF DECK/138SF LOG/120SF PORCH/96SF PATIO Type RESDNTL Sub Type SFD Phone 7604271926 Job Address 1945 COBALT DR Suite Lot 74 Location Inspector f^£ OWNER WARMINGTON TRIESTE ASSOCIATES L P Owner Remarks Total Time Requested By KYLE ISBELL Entered By CHRISTINE CD Description Act Comment 11 Ftg/Foundation/Piers 12 Steel/Bond Beam 21 Underground/Under Floor 31 Underground/Conduit-Wiring Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 06-35 Inspection History Date Description Act Insp Comments 03/02/2007 21 Underground/Under Floor AP MC BACK FLOW PREVENTER REQ 03/02/2007 22 Sewer/Water Service PA MC 03/06/2006 16 Insulation AP RB HUNSAKER ^ASSOCIATES DIEGO N C PLANNING ENGINEERING SURVEYING IRVINE LOS ANGELES RIVERSIDE SAN DIEGO March 6, 2007 ARIZONA City of Carlsbad Engineering Department 1635 Faraday Avenue Carlsbad, CA 92008-7314 Re Building Form Setback Certification La Costa Greens Neighborhood 1 17 Carlsbad Tract 04-09/PUD 04-08A Drawing No 429-2C Lots 6 through 9, 72 through 74, and 102 through 107 Dear City Inspector Please be advised the building foundation forms are in conformance with the precise grading plans as to horizontal and vertical location The building setbacks were measured in relation to the property lines and were found to be in conformance with the approved precise grading plans for this property Sincerely, Daniel P Smith " L S 6854 Hunsaker & Associates San Diego, Inc DAVE HAMMAR LEX WILLIMAN ALISA VIALPANDO DAN SMITH RAY MARTIN CHUCK CATER 9707 Waples Slreet S.in Die-so CA 92121 (858) 558 4500 PH (858)558 1414 FX www HunsjkerSD com InfoOHunsakerSD com MP kc k \0107\2007\c79 doc wo 0107 268 3/6/2007 4 01 PM < SOIL it TESTING INC SOUTHERN CALIFORNIA SOIL & TESTINQ INC. 6280 RIVERDALE STREET, SAN DIEGO, CA 921 20 • Phone (6 19) 280-4321 Fax (619)280-4717 83-740 CITRUS AVENUE, SUITE G, INDIO, CA 92201 • Phone (760) 775-5983 Fax (760) 775-8362 SCS&T FILE NO - 63406 "2, 1 PO NO. V PL NC FIX PAGE 'OF FIELD INSPECTION. REPORT FOR Q REINFORCED CONCRETE J Q REINFORCED MASONRY Q WELDING D FIREPROOFING ~]Q C. CONCRETE D ROOFING/ WATERPROOFING ITXPT CONCRETE/STRESS D EPOW ANCHORS QHS BOLTING Q PROJECT TITLE •— ~f} , *" £ — ' JCT PHASE*DSA FILE NO DSAAPPNO PROJECT ADDRESS PERMIT NO PLAN FILE NO ARCHITECT Hc£MaUJflLCA ENGINEER GENERAL CONTRACTOR I SUBCONTRACTOR r.u.MS LOCATION OF WORK INSPECTED B - DATE DESCRIPTION OF WORK INSPECTED TIME ARRIVED TIME DEPARTED THc 0 MIL./ ou UD CO 7^1 2-x: 45 IAJ Pi_OC6, I flu' PE REVIEW UBC I hereby certify that I have Inspected the above reported work Unless noted otherwise ttie work inspected Is to the best of my knowledge In compliance with the approved plans specifications and applicable sections of the governing building laws Inspector Initials T~C_ DSA I hereby certify that I have Inspected the above reported work in accordance with the requirements of DSA approved documents. Sampling and testing were conducted In accordance with the requirements of the DSA approved documents The work Inspected mptesavtth the DSA approved documents Yes, i V-°.Mo . Inspector Initials INSPECTORS SIGNATURE REGISTRATION NO 3//207 •SUPERINTENDENTS SIGNATURE 'signature authorizes 1he above work DATE SCS&T 205 REV 2/06