HomeMy WebLinkAbout1947 MARCASITE PL; ; CB073058; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
06-26-2008 Residential Permit Permit No: CB073058
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
1947 MARCASITE PL CBAD
RESDNTL Sub Type:
Lot#: 2132922300
$314,169.24 Construction Type:
SFD
55
VN
Status:
Applied:
Entered By:
ISSUED
12/12/2007
JMA
Occupancy Group:
06/26/2008
Reference#: CT 04-09 Plan Approved:
# Dwelling Units: 1 Structure Type: SFD Issued: 06/26/2008
Bedrooms: 4 Bathrooms: 4 Inspect Area:
Project Title: TRIESTE PL 2: PHS 6, 2745SF LV Orig PC#: PC 06-35
639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF PATIO Plan Check#: PC 07-76
Applicant:
WARMINGTON HOMES
701 PALOMAR AIRPORT RD
CARLSBAD CA 92011
931-4766
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
STD #2 Fee
STD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$1,318.65
$0.00
$857.12
$0.00
($68.57)
$31.42
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$7,702.00
D1
$0.00
$0.00
Owner:
WARMINGTON TRIESTE ASSOCIATES LP
C/O WARMINGTON HOMES CALIFORNIA
3090 PULLMAN ST #A
COSTA MESA CA 92626
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $27,733.13 Total Payments To Date: $27,733.13 Balance Due:
$0.00
$225.00
$7,188.00
$3,618.63
$5,717.88
$0.00
$0.00
$0.00
$750.00
$0.00
$0.00
$259.00
$60.00
$74.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$27,733.13
$0.00
Inspector: t'A ~ FINAL Af Pl OVAL
Date: l:)L I I L c, ~ Clearance: <, ::);J.:9'\
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reseivations, oi-other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fee.~/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bcir any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or se,vice fees in connection with this projo.!t. NOR DOES IT APPLY to any
nf .. ,hinh"'"' ,,t,.Jf'\Tli'~ ' ' ,.,,,,.+,.,.,h;,,h+h,,_,.1,,1,,+,,_nf' C't"'"
City of Carlsbad Bldg Inspection Request
For: 06/15/2009
Perm it# CB073058 Inspector Assignment: MC
Title: TRIESTE PL 2: PHS 6, 2745SF LV
Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF
PATIO
Type: RESDNTL Sub Type: SFD
---
Phone: 7608818240
Job Address:
Suite:
Location:
1947 MARCASITE PL
Lot
APPLICANT WARMINGTON HOMES
55
Inspector: -~f'A?~--
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks:
Total Time:
CD Description Act
19 Final Structural a
29 Final Plumbing t 39 Final Electrical
49 Final Mechanical
Comment
Ok,. 1"0
Requested By: KYLE
Entered By: BARBARA
IZ,i:1~~ 6aA.5 ~
~LU.. 17ME. "f'h-S z,(L-
rJ.oN~ t-ter"JI.LUc:.. 'P~P""'-~'->-t" ~Is-o/l..
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lns~ection Histor)I
Date Description Act lnsp Comments
05/07/2009 39 Final Electrical AP MC EMR ONLY
03/02/2009 17 Interior Lath/Drywall PA MC DRYWALL ONLY
03/02/2009 18 Exterior Lath/Drywall AP MC
03/02/2009 23 Gas/TesVRepairs AP MC
02/24/2009 16 Insulation AP MC APP. 2/23/2009
02/23/2009 16 Insulation AP MC
02/19/2009 27 Shower Pan/Roman Tubs AP MC
02/19/2009 84 Rough Combo AP MC
02/18/2009 84 Rough Combo PA MC MINOR PICK UP
02/17/2009 84 Rough Combo co MC SCRAP OUT
01/26/2009 13 Shear Panels/HD's AP MC
01/09/2009 15 Roof/Reroof AP PC
11/05/2008 81 Underground Combo AP RB
m . • . City of Carlsbad Bldg Inspection Request
.
For: 05/07/2009 .
Permit# CB073058 Inspector Assignment: MC
Title: TRIESTE PL 2: PHS 6, 2745SF LV
Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF
PATIO
Sub Type: SFD
---
Type: RESDNTL Phone: 7608818240
Job Address: 1947 MARCASITE PL
Suite: Lot: 55
Location:
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks:
Inspector: Ml---=-----
Total Time: Requested By: KYLE
Entered By: JANEAN
CD Description Act Comments
39 Final Electrical _H. IE.Ke. OM~""(, O"'-:to f.:pi FA~IQ
----------------~smz.
---· ------------
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lnsgection Histo[Y
Date Description Act lnsp Comments
03/02/2009 17 Interior Lath/Drywall PA MC DRYWALL ONLY
03/02/2009 18 Exterior Lath/Drywall AP MC
03/02/2009 23 GasfTest/Repairs AP MC
02/24/2009 16 Insulation AP MC APP. 2/23/2009
02/23/2009 16 Insulation AP MC
02/19/2009 27 Shower Pan/Roman Tubs AP MC
02/19/2009 84 Rough Combo AP MC
02/18/2009 84 Rough Combo PA MC MINOR PICK UP
02/17/2009 84 Rough Combo co MC SCRAP OUT
01/26/2009 13 Shear Panels/HD's AP MC
01/09/2009 15 Roof/Reroof AP PC
11/05/2008 81 Underground Combo AP RB
10/28/2008 21 Underground/Under Floor AP MC WASTE ONLY
10/28/2008 22 Sewer/Water Service AP MC
10/27/2008 21 Underground/Under Floor co MC PROVIDE TEST
10/27/2008 22 Sewer/Water Service co MC
a CltJ of Carlsbad
lll;3 Flnal Bulldlna Inspection
Dept: Building Engineering Planning CMWD St Lite Fire
Plan Check#:
Permit#:
Project Name:
Address:
Contact Person:
Sewer Dist:
PC 07-76
CB073058
TRIESTE PL 2: PHS 6, 2745SF LV
639SF GAR/11 0SF DECK/138SF LOG/120SF PORCH/103
1947 MARCASITE PL
Phone:
LC Water Dist: CA
Lot:
Date:
Permit Type:
Sub Type:
55
MY1c:29
05/14/2009
RESDNTL
SFD
..........................................................................................................................................................
Inspected ~~ Date
S {.s[u'j_ By: c_ Inspected: Approved: Disapproved: _X_
I
Inspected Date
Approved: ~sapproved: __ By: Inspected: ,+~(1>'1
Inspected Date
By: Inspected: Approved: Disapproved: __ ...........................................................................................................................................................
Comments: ______________________________ _
-•
1'11\NNINC;
HUNSAKER
&ASSOCIATES
S /\ N !• I 1 li !I, I N I,
ENCINEE.iNC October 31, 2008
~lll•Vt YIN(;
IHVINt
'°' ,,N~fl F5 City of Carlsbad
. "v""""· 1535 Faraday Avenue
'·""""'·'c I b d cA 92ooa.731 /\kl/.UNA ar s a ' 4
Attention·
Regarding
Reference:
District Grading Inspector
Civil Engineer's
Certification of Final Grading
Project
Drawing No:
Lots
La Costa Greens Neighborho :Jd 1.17
429-2C
50 through 63
Pursuant to Section 11.06.170 of the Carlsbad Municipal C )de, I hereby state ,n
my professional opinion all work incorporated in the gradin!I and drainage plans.
authorized under the grading permit to Include grading, dra nage and
construction of appurtenant structures, has been constructud to the lines and
grades in substantial conformance with the approved plans and any approved
revisions thereto.
I further state that the embankmenl and cut slopes as sho"' n on the approved
grading plans have been placed al their proper line and grade.
Respectfully submitted,
a.\&.,m -
Daniel P Smith L.S. 6854
, ,.v, 11,,,.M,1< Hunsaker & Associates San Diego, Inc.
I.EX WILLIMJ\f',I
ALIM VIALl'ANUl J
01\N SMITH
1(/\Y M/\lfl!N
r:t·ll!Ct.: CAIi !~
~1707 WJf-111•~ 'ivcct
,'~,111 IJ1p1:11, CA 'l,!l:•1
{Wil.11 J'.'itl-4500 l'H
(lllilll ~!ll\-1,l l•t I l(
www.H11n~,,krSO .I', u\\
hl(u~lM, 111~.1k~'l'3lJ.,:,11,,
lOO/lOO~ as Jossv pue ,a~esunH
DS h 11. 1111u11,11a111mo 1111r.•
... o 01()) ~o~ 1oi,112001~~UAM
P(Pl899898l XV, ,P ll 800l/OC/Ol
PL I'
FIELO'.INSPECTI~~ REPORT FOR; . I;] REINFGR'.CED·CON<:::~ETE' ~ ,, ,1 [j REJNFORCED MASONRY O ,WELDING ,: "
,Q, c'. CONCRETE . ROO~ING' / ,WATERPROOFING ~ONCRETE / sm~ss [] ;,EPOXY ,ANCHORS
'' ,uac .1 herel;)y certi(Y.lt:lot I have lns~ted the·Obo;ve report~d·wo1k. Wnless r;iote<i:I olherWlse.
'the work Inspected Is to t)1e best 9f.my,kn0Wledge Ir, compl\ance with th~ qi:iprove,d plans, ·
1specmcoti0ns a~d a~~llc ble ;s : , sol ,1he povernlng'.bulldl[)gJaws; ~ ... , ,. , , i: 1
·'.
lnspe<;tor Jnttials ' , '. ' ;f ·
o·, Ir,-•• , J ' ,,'. . 1 I r t}!
·DSA I hereby:certl(y th t I hcive IQSpeded t~e; above report~ wort<·ln acc91.d~nce wtth the .
requlremenf~ at DSA opproved;documents, Sprripllng and·testlng were co~i;icted ln1
occordonce'.Wfth' the requlremeots of !tie DsA 'owroveGJ docur'nE1nts,, ThEfWort<',lnspecled·,
c9(:l')plles with fne DSA opprovek!' documents. . . ' ·"
Yes:_·_· -·" No: I.___2, lns~tor Jh(ll~I;: 'i
GEOCON O O ..
IN°CORP ORATED • ~;
6960 FLANDERS DRIVE ■ SAN DIEGO, CALIFORNIA 92121-297 .4 ■ TEL (858) 558-6~~T~H~~~L (~~:iS~!:~~9 ~~
FOUNDATION OBSERVATION REPORT ~~:~:zAMEcZ w,,::t() -/.JI
FOUNDATION LOCATION (if not entire building) t ,,I< £tt-Si.
PLAN FILE NO. PERMIT NOS :
L, f ~4 Pu-··.,_ C 6'11 :iC; ~
Sf> ( 13 Q1 "30 ~<ii
FOUNDATION TYPE : 51., C 11 Oi 3<1<;~
0 CONVENTIONAL n cs IJ '50
,,, POST·TENSIONED , I st ,;/ c3 (J Ht!.
'"' r .'O 0"'1 "Sll /. •
•. PUjPOSE OF OBSERVATION
¥'verify soil conditions exposed are similar to those anticipated
PROJECT NO. o/,lfq3 -Gt.~ Z(~
DATE : Jl/5/ot
0 ADDITIONAL OBSERVATION REQUIRED ,
Pl{ SUBSTANTIAL CONFORMANCE
'
121(verify footing excavations extend to minimum depth recommended in soil report
D Verify foundation reinforcement complies with minimum recommended in soil report
D Verify slab reinforcement, . sand bedding and moisture barrier comply with minimum recommended in soil report
~ Verify footings have been extended to an appropriate bearing strata
D Other
• SOIL REPORT RECOMMENDATIONS BASED ON:
_p( Expansion Condition □ VERY LOW □ LOW y MEDIUM □ HIGH □ VERY HIGH
, Fill Geometry -"""""'""""-'·--------------------------------
fi(J Other ~ Lal s s~ -5& C,tff ::[.. , Loh 5':{ -5 '1 CA(.lL .,
• MiNIMUM FOUNDATION RECOMMENDATIONS:
§(°Footing Depth : □ 12 Inches ll!I 1fY1hT"Jlis 5{' 241A\:iJ[.. OTHER __________ _
Footing Reinforcement: D No.4 T&B D 2-No.4 T&B □ 2-No.5 T&B □ Post-Tensioned OTHER : _____ _
Interior Slab Reinforcement : D 6x6-10/1 0 D 6x6-6/6 D No.3@241nches D No.3@181nches D Post-Tensioned
Slab Bedding Material and Thickness : -------~----Vapor Barrier :
Fo,adat;on Wodth • ~:: ::: ::ti:x--;,,a(
• OBSERVATIONS :
~ J ubstantial conformance with
~Substantial conformance with
.Ja~:#: '"2Q'23
Soil Reports (see "Purpose of Observation!') ./ ./
Foundation Plans. 1 dentify : -rr--P-i'k"\o'•,r1":i>>---!-¥r--11~.1_.""'J~..,.o..,()>+->,,-' _1.,01.,-t ... PL~q~( ...... , __
0 Other
• COMMENTS : ---:;;,~------------------------------
TIS ASSUMED THAT All FOOTING EXCAVATIONS Will BE QEANED Of LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT TI-E SOil MOISTURE CONTENT Will BE MAINTAINED
AELD t9fIES TO
•< SOIL I!. 1 ~STING. INC. z a: fi: :i ~ z ffi
Southern California Soil and Testing, Inc.
6280 Riverdale Street, San Diego, CA 92120 (619) 280-4321
P.O. Box 600627, San Diego, CA 92160-0627 ·:,; ... ::, 0 "'
83-740 Citrus Avenue, Suite G, Indio, CA 92201-3438 (760)775-5983
Concrete (4x8) Compressive Strength Test Report
File Number: 0612215
Project Title: Trieste at La Costa Greens PTCC Phase: 6
Project Location: 1947 Marcasite Place
Architect: n/a
Engineer: Permit No: CB073058
Contractor:
Davidson Reinforcing
Warmington Plan File No:
Location In Structure: Lot: 55 NE Quad
Material Supplier: Superior
Mix Designation: 375p
Admixture(s): n/a
Time In Mixer:
Air Content: (ASTM C173/C231)
Air Temp:
Truck Number:
Samples Made By: (ASTM C31)
Laboratory Number
Mark On Samples
Date Made
Date Received
Date Tested
Diameter, Inches
Area, Square Inches
Maximum Load, Pounds
Compressive Strength, psi
Age Tested
Required 28 Day Strength, psi
Fracture Type
75 minutes
80 degrees F
217
MJB
0879646
LOT55
11/6/2008
11/7/2008
11/17/2008
4.00
12.57
58,930
4690
11 Days
4500
Slump inches: (ASTM C143)
Unit Weight Plastic/Dry, pcf: (ASTM
C138/C567)
Concrete Temp: (ASTM C1064)
Ticket Number:
Samples Tested By:
0879647 0879648
11/6/2008 11 /6/2008
11/7/2008 11/7/2008
12/4/2008 12/4/2008
4.00 4.00
12.57 12.57
73,100 74,060
5820 5890
28 Days 28 Days
4500 4500
1 2
5.00
I
80 degrees F
62967
CN DH
Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM C39
standards. This agency makes no other warranties express or implied.
Fracture Type: 1 -Reasonably well formed cones on both ends, less than 1 in. of cracking through caps; 2 -Well formed cone on one end, vertical
cracks running through caps.no well defined cone on other end; 3 -Columnar vertical cracking through both ends, no well formed cones; 4 -Diagonal
fracture with no cracking through ends; 5 -Side fracture at top or bottom (occur commonly with unbonded caps); 6 -Similar to type 5 but end of
cylinder is pointed.
_.-......,
Distribution: Reviewed By: L (1) City of Carlsbad -Building Inspection Department ~ (1) Warmington Homes California
-;
Gordon T.M. Woodard RCE # 60481