HomeMy WebLinkAbout1949 KELLOGG AVE; ; CB061428; Permit, I
I
City of Carlsbad ·
06-29-2006
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB061428
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
1949 KELLOGG AV CBAD
Tl Sub Type:
Lot#: Status:
Valuation:
2120920800
$8,500.00 Construction Type:
INDUST
0
NEW Applied:
Occupancy Grqup:
Project Title:
Applicant:
CROWN LIFT
12255 KIRKHAM RD
POWAY, CA 92064
619-696-6747
Building Permit
GIA -1184 SF RACKING
Add'! Building Permit Fee
Plan Check
Add'! Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTb #2 Fee
BTD#3 Fee
Renewal Fee
Add'I Renewal Fee
Other Suilding Fee
Pot. Water Con. Fee
Meter Size
Add'! Pot. Water Cori. Fee
Reel. Water Con. Fee
Reference #: Entered By:
$91.99
$0.00
$59.79
$0.00
$0.00
$1.79
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0;00
$0:00
$0.00
$0.00
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
YUEN FAMILY TRUST 09-13-95
PO BOX8822
RANCHO SANTA FE CA 92067
Meter Size
Adel'! Reel. Water Con. Fee
Meter•Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
HMP Fee
TOTAL PERMIT FEES
Total Fees: $153.57 Total Payments To Date: $153.57
lnspecto~~ Clearance:
ISSUED
05/22/2006
JMA
06/29/2006
06/29/2006
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
??
$153.57
NOTICE: Please take NOTleE that approval of your project includes the."lmpositiori" of fees, dedications, reservations, or other exactions hereafter collectively
referred toas "fees/exactions." You have 90 days from the date this permit was-issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accoraance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other. similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have reviousl · en iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired.
PERl)/IIT APPLICATION
I
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
0614201-2 0021 05/22/2006 001 33
FQ3:!EMACa~e':iONLY
,PLAN CHECK No.O?Qk (4:z.!?
EST. VAL. __ _;:8fh:P~;...,,:;._;:_ ____ _
Plan Ck. Deposit ________ _
Validated By=1(V'\Pr
Date S7~Q.h-.
Address (include Bldg/S~te #) ..,.--;; ~ \ J . t' ,P. Business Name (at this address)
Lo1' L\'-l ~ U'N--5'6t.Y \ ~~ ~\-l.\, ·µ\\' t ,tl 1\:1\f C\'tV\ of' Q'lv\.J'(J"t:>-J)
Legal Description Lot No. Subdivision Name/Number :' 1 Unit No. Phase No. Total # of units i \ 'L . 0 C:.,1..,, 0 6 ..L ~ -M bMvfA U\.NE "i-h UL)
Description of Work #of
Name Address City State/Zip Telephone#
[f; ·:. ;ri!!.ERU&VfN~li.
"•-' ~._,.,.... ...... ,, • .,,,,¥ -~ ',..,,,..,." '· ··· , ....... ::·~::~i::·,~Yti~~:-~r:.:: -'"·;·-'-F•··"'-"'1{·f,~::·:21~&~t!if (qt:Q
(Sec. 7031.5 Business and Professions Code: Any City or County which requires _a permit to construct, alter, improve, demolish or repair any structure, prior to its
issu.ance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
ption. Any vi lation of Section 7031.51 '}v any applicantJ?~ a permit subjec~ the applicant to a civil penalty of n t more than five hundred dollars [$5001).
ov.U ~ t'l.-S5 l',,\r,Jl,\Jhl'I \\.I>• '-\OC Tow 9lo~'-\ Ln\9. l.o <o, C~~1'
Name .
State License # lg \ ) S:: 8 . ~ Address City State/Zip Telephone#
.; ' U''-"\.. ~ C); s Vi "'.
Designer Name
State License # ----'------~-[F:':w~'.'ooMPENSARo'N-~--.·· "·~.--. -=-.. -"-. --.. _-. -_ .. -.. -. ~-~.........,-:---:-:·:·--. -.-°"' ?;7 ;:-:;:· ":' ~T,~T"::::i;Ll':.~;b~ ; · .. ~."1:':;s/'~·:.~;:,"7 :·.:;::,. ;s·:;,~:1~
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
0 I have and will maintain a certificate of consent to self-insure for worker!,' compensation as provided by Section 3700 of the Labor Code, for the performance
~ the work for which this permit is issued,
~ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are: . / l "·
Insurance Company 6 C,,o@ . Policy No. L tJ\ b \ O '3 S" VO Expiration Date \ t>:_ v \ _ -0 Y . t (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which thii; permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Comp sation Laws of California. ,· icoh,,.
WARNING: Failure to secure workers' com ensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars 0,000), in ition to t e cost of Cf!!'Pensat· '!: darpages_ as provided for in Section 3706 of the Lab code, 'nterest and attorney's fees.
~SIGNATURE firfflrJT' 'f' ~~ DATE (} 0 \.,
tz:,'.'::roc:~NARtllWl,iQl;@.c!;.i\il~' ...... :, :: . _:: ·:·~: '. c.:.: ~-:_:'!-:~:::.·.~ ·:.::.:.::=.:::.0·:~:·.
I hereby affirm that I am exempt fr the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within orie year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I, as owner of the pro~erty, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted.with the following person (firm) to provide the proposed construction (include name/ address/ phone number/ contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number):, _____________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):. _________________ ~------------------------------------
PROPERTY OWNER SIGNATURE _____________ ~--------DATE ________ _
icOMJ>]'(:I.E'.iiH1s'"'"secTjoN;FOR:tif}N,RSJPEN:TfA£:BUjCOJN(l:PERMl;'(S10NL:Y;: ~: ;. ', /•c ,, ,. ; 5, .. _,.,,,;, ,· •.. ,· ·:,~;'."/;';;JC•f-'.~,:,:~r:. v'.7;:p -~ ._,,,.~,.,-,·-,.; ... ,,.~.,,.,.,'.!':"!"'"
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES 'r'::J NO
Is the facility to be-constructed within, 1,000 feet of the outer.boundary of a school site? 0 YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
f~C®N$t®::~19..::l.iffiPJ[UqENC)'"-':=2~::t~·-;~~ .... ~.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S ADDRESS LENDER'S NAME:;;;;;;;;;;::;;;:;;;:;;;:;;::;;;:;;::;;;::::;::::::;:::::;::::::=:=:=:::::;:::::::.,.
~~:-~:..fife!!U~~1tr::.ttem11:1~AtlP,~1 ,,;,: ~.,,; ~-~:_-_:_;__; /~--:.,~:-~: ~~.~.2 ~!/, ~~:~~-<-,·;~;,,.:;~;~,.:\~~~~~-~~,~;:2~~;~;~ ~~~-:~~-{:?'~~-~~-.l~;};~~1.;,!;~_ ¥;:Z~%t7:~.N~:;~:;;~-z~;:-~=-:~;<!:; ~r~~
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize represElntatives of the CiW of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official -under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced wit · 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is com ed for a of 180.days (Section 106.4.4 Uniform Building Code). / ¥
APPLICANT'S s1GNATURE '"...n f' WW~ DATE S l~o $o
I YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg· Inspection Request
Permit# CB061428
Title: GIA -1784 SF RACKING
Description:
For: 07/14/2006
Type: Tl
Job Address:
Sub Type: INDUST
1949 KELLOGG. AV
Suite: Lot 0
Location:
OWNER YUEN FAMILY TRUST 09-13-95
own~r: YUEN FAMILY TRUST 09-13-95
' Remarks:
Total Time:
CD Description Act Comment
19 Final Structural
Comments/Notices/Hold
Associated PCR.s/CVs Original PC#
Inspection History
Date Description Act lnsp Comments
Inspector Assignment: MC
Phone: 6196665694
Inspector: L
Requested By: MONTY
Entered By: CHRISTINE
07/12/2006 19 Final Structural CO MC SEE NOTICE ATTA¢HED
' --, ~ r1.=:..-. '\.' ~
,' ea-'"-;» -i
~-;.-:; -\1=. ::::::::;:::== ·-~~1;!;?11· Corporati··o·n
· -I-"-;..-·-:--,:;rslifp. witli .government for <BuirJ.lng Safety . n.-.cartne:
DATE: 6/26/ ,r ,
' c/ :;_ ~:.~_-::1_.
JURISDICTION: City ·ot Carisb~
PLAN CHECK NO.: 06~428 ·~ :·~~--:.-:j
j -.,':;.~-.. , ·_ t
PROJECT ADDRESS: 1949 ~YiiAve.
PROJECT NAME: GIA Stor~ge Racks
SET: II
~
ANT
JURIS.
Cl REVIEWER
Cl FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified be.low are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact per~on.
D The applicant's copy of the check list has been sent to:
~ Esgil. Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant at the plan check has been completed.
Person cohtacted: el pho #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax
~ REMARKS: 1. Fire D_epartment · prova is required. 2. City to field verify that the path of travel
from the handicapped parking ace to the rack area and the bathrooms serving the rack area
comply with all the current di bled access requirements.
By: David Yao
Esgil Corporation
D GA D MB DE
Enclosures:
6/16 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
\
'\
EsGil Corporation
In <Partnersliip witli government for <Buifaing Safe'ty
' DATE: 6/5/-06
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 061428
PROJECT ADDRESS: 1949 Kellog Ave.
PROJECT NAME: GIA Storage Racks
SET:I
Cl PLAN REVIEWER
Cl FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
O· The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
12s] The check list transmitted herewith is foryour information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the Check list is enclosed for the jurisdiction to forward to the applicant
contact person.
12s] The applicant's copy of the check list has been sent to:
Chris Simpson 10054 Prospect Ave. #B Lakeside, CA
D Esgil. Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Chris Simpson Telephone#: 619-971-9000
Date contacted:UJ /e, /Of.tJ(by/.~.i) Fax #: & /q -5'1 ~ -tf-C// 'f
Mail Telephone v°FaxV In Person
D' REMARKS:
By: David Yao Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 5/25 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
j
City of Carlsbad 061428
'6/5/06
GENERAL PLAN CORRECTION LIST
JURISDICTION: City of Carlsbad·
PROJECT ADDRESS: 1949 Kellog Ave.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 5/25
REVIEWED BY: David Yao
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 061428
DATE REVIEW COMPLETED:
6/5/06
Thi~ plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, ~ational Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan revi~w is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departm~nts.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approvat of the plans-does not permit the violation of any
state, county or city law.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
D Yes D No
i v'
..
City of Carlsbad 061428
6/5/06
1. · Only the storage racks are included in this plan review
2. Provide a statement on the Title Sheet of the plans that this project shall comply with
Title 24.
3. Provide a note on the plans indicating if any hazardous materials will be stored and/or
used within the building Which exceed the quantities listed in UBC Tables 3-D and 3-E.
4. City to field verify that the path of travel from the handicapped parking space to the rack
area and the-bathrooms serving the rack area comply with all the current disabled access
requirement$. Title 24, Part 2.
5. Obtain Fire Department approval for groups F, Mand S occupancy storage per UBC
Sections 306.8, 309.8 and 311.8.
6. Indicate the clearance from the new racks to the existing building walls and building
columns.
7. Provide forklift protection per Section 2222.5.(or check the exception)
8. She$t 16 of the calculation shows the load for type C double row is 1600lb for level 1 and
2. The note 3 on sheet SCE1 of 1 of the plan shows type c double row-2500# per level.
Please check.
Rech~ck the "pallet" racks as follows:
9. Recheck all connections on sheet 1 as follows:
a) The rivet bearing capacity is only dtFu = 0.406(0.0747)65 = 2 kips.
b) Provide calculations for all beam to bracket weld capacities per Section 2330
(allowable weld stress is the member thickness times 26 ksi times 1.33, or the
weld stress, whichever is lower).
c) Check the bracket maximum weak axis moment.
10. · Provide calculations for the column weak axis bending plus axial for transverse seismic
loading. The axial load is the maximum compression load at the base from vertical plus
seismic overturning. The column moment Will probably be maximum for the lateral load
from the base plate to the first diagonal brace (not ohly to the first horizontal member).
11. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 921.23; telephone number of 858/560-1468, to perform
the plan review for your project. If you have any questions regarding these plan review
items, please contact David Yao at Esgil Corporation. Thank you.
City of Carlsbad 061428
6/5/06
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: David Yao
PLAN CHECK NO.: 061428
DATE: 6/5/06
· BUILDING ADDRESS: 1949 Ke11og Ave.
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
!3UILDING AREA Valuation Reg. VALUE
PORTION ( Sq. Ft.) Multiplier Mod .
. .
storage racks per city
Air Conditioning
Fire Sprinkl~rs
. TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee ~Y Ordinance • I
1994 UBC Plan Check Fee • I
Type of Review: 0 Complete Review D Structural Only
D Repetitive Fee
3Re·peats
Comments:
D Other
D Hourly I Hour *.
Esgil Pla;in flevlew Fee
($)
8,500
8,500
$91.99j
$59.791
$51.51 j
Sheet 1 of 1
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERNITNUMBliRCI 0bll(J-f3 DATE YZ3 ~ob
ADDRESS f q ~ 1 In rf ass fl-,)fj,ilf
.RESIDENTIAL
RESIDENTIAL ADDITION MINOR
. (<$10,000.00)
.
. OTt,ER ~9 ~
..
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLACE FAIRE
COMPLETE OFFICE BUILDINC
PLANNE~k. DATE ~ 2-S ,o~
ENCINE~---. ___,,~------DATE ,5(ki4',/4 ~
BUILDING DEPT.
C~rlsbad Fire Department COPY
Plan Review Requirements Category: HI , HPCSTOR
Date of Report: 06-06-2006 Reviewed by: ___ 4_? /rt ___ _
Name:
Address:
Permit.#: US060046
Job Name: GIA
CROWN LIFT
12255 KIRKHAM RD
POWAY,CA
92064
cOCJ6/c/~
Job Address: 1949 KELLOGG AV CBAD
--. .. ..... The item you have submitted for review is incomplete. At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review
carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval.
Conditions:
Cond: CON0001397 GoVFp)i-ms PROJECT HAS BEEN REVIEWED
PROVED FOR THE PURPOSES OF ISSUANCE
OF BlJILbING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION
AND REQUIRED TEST, NOTATIONS HEREON,
CONDITlONS IN CORRESPONDENCE
AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT ]3E HELD TO PERMIT
OR APPROVE THE VIOLATION OF A.NY LAW.
Entry: 06/06/2006 By: GR Action: AP
-~trJ!ihJral
\.,once ts
ngineering
1729 S. Douglass RD, Ste B Anaheim, CA 928Q6 Tel: 714.456.0056 Fax: 714.456.0066
Project: GIA
Project #: F-041006-5
. Oat~: 06/07 /06
1949 KELLOGG AVENUE
CARLSBAD,CA.92008
Project #: 61428
Plan .Review Responses
STRUCTURAL REQUIREMENTS:
1. UNDERSTOOD
2. PLEASE SEE-ADDED NOTE ON PLANS AS R~QUIRED.
3. PLEASE SEE ADDED NOTE ON PLANS AS REQUIRED.
4. UNDERSTOOD, CITY TO VERIFY ALL REQUIRED HANDICAPPED ACCESS REQUIREMENTS.
5. FIRE DEPARTMENT APPROVAL TO BE OBTAINED PRIOR TO ISSUANCE OF PERMIT.
6. MINIMUM DISTANCE FROM NEW RACKING TO ANY BUILDING WALLS OR COLUMNS TO BE 6".
7. PLEASE SEE RE'(ISED CALCULATIONS, PAGE 7.2 WHERE COLUMN HAS BEEN CHECKED FOR ADEQUACY WITHOUT
THE USE OF :POST PROTECTORS Pl;R SECTION 2222.5 OF THE CODE.
8. PLEASE NOTE THAT TYPE C IS ONLY ONE LEVEL AT 2500#, PLEASE SEE REVISED CALCULATIONS PAGE 16.
9. PLEASE SEE REVISED CALCULATIONS PAGE 9 FOR REVISED CONNECTION ANALYSIS AS REQUIRED.
: . 10. PLEASE SEE REVISED CALCULATIONS PAGE 7.3 FOR WEAK AXIS BENDING ANALYSIS OF THE COLUMN AS
REQUIRED.
PLEASE FEEL FREE TO CALL WITH ANY QUESTIONS YOU MAY HAVE REGARDING THE ABOVE MATTERS.
SINCERELY,
tructural
ancepts
1729 S. Douglass Rd, Suite B
Anaheim, CA 92806
Tel: 714.456.0056 Fax: 714.456.0066
e-mail: sceng@englneer.com
Prqject Name: GIA
Prqject Number : F-041006-5
Date : 06108/06
Street: 1949 KELLOGG AVENUE
City/State : CARLSBAD, CA. 92008
Scope of Work: STORAGE RACKS
JUN 1 2 2006
S-trur.turol
· Co~c~ts
~-1::ngineering
1129 S _ C>ouqloss Rd Ste 8 Aoobeirn CA ·92806 IeJ· 114 456 QQ56 Eox· 714 456 QQ66
_By: BOB Project: GIA Project #: F-041006-5
TABLE OF CONTENTS
Title-Page ............................... -............................................................................. _ ..
Table of Contents .......... _ ................................................... _ ..................................... .
Design Data and Definil;ion ofComponents ........................................................... .
Critical Configuration ..................•..........................•....•...... , ............................. _. ..... .
Seismic Loads ................................................................ -........................................ .
Column ................... _ ........ -...................................................................................... .
Beam and Connector ............................................................................................... .
Bracing ............................. -..................................................................................... .
Anchors ....................................................................................................... -.......... .
Ba$e Plate ............................................................................................................... .
Slab on Grade ...................................................................... _ ....................... -.......... .
Other Configurations ............................................................................................... .
1
2
3
4
5to6
7
Sto 9
10
11
12
13
14TO l':f-
TYPE A 5ROGIA Paqe 2--of ( q... 5/1 G/200G
~rur--turol
· C~nc~ts · ·
.~ l:ngineering
· ·· . 1129 S Do11qloss Rd Ste B 4oobeitn C4 92806 Tel· 714 456 QQ56 Fox· 714 456 QQ66
By: BOB Project: GIA Project #: F-041006-5
Desig!1 Data
1) Toe analyses conforms to the requirements of~ 2001 CBC, utilizing division X of chapter 22 and section 1630.2
2). Transverse braced frame steel Cbnforms to ASTM A570, Gr.55, with minimum strength, Fy=.55 ksi
Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy=55 ksi
All other steel conforms to ASTM ft36, Gr. 36 with minimum yield, Fy= 36 ksi
3) Anchor bolts shall be provided by installer per ICBO reference on plans and calculations herein. Installer must
provide any special inspectipn as called out on· plans or calculations, or as required by the ICBO report indicated herein.
4) All welds shall conform to AWS procedures, utilizing E7Oxx electrodes or similar. All such welds shall be performed
in shop, wii:h no field welding allowec:l.other than those supervised by a licensed deputy inspector.
5) ihe slab on grade is 5" thick with minimum 2000 psi compressive strength. Soil bearing capacity is 500 psf.
Definition of Components
Frame
Height
A
....... ~ . -......... ::::::::: Beam
\=/ !{!}{( Spacing
t=:H§~:§§~~::!::' ::;::;==:::!i:
Beam
Length
Front View: Down Aisle
(Longitudinal) Frame
Column
Beam to Column
Connector
Base Plate and
Anchors
r-~n;,
Section A: Cross Aisle
(Transverse ) Frame
Horizontal
Brace
Diagonal
Brace
The components herein ate designed within the guidelines of the 2001 CBC and with due
regard to established industry standards set forth by the Rack Manufacturer1s Institute.
Building official· must approve final submitted design.
TYPE A 5ROGIA f'aqe J of J'f--5/1 G/200G
I
S1-rur.turol
· CoitcE ·
"Jii1 . lm~"l!':loss Rd Ste B Anaheim C.4 92806 Toi· V4 456 0056 fax· V4 456 0066
By: BOB Project: GIA Project #: F-041006-5
Configuration & Summary: TYPE A SINGLE ROW
Seismic Zone
. 4-(Na~l.0)
_ llong=0.27 sec/ Tsnort=0.15 sec
Componerit
Column
Column Backer
Beam
Beam Cormecror . ..
Brace-Horizontal
Brace-Diagonal
Base Plate
Anchor
-Slab
Level ,Per~el
1
2
3
Notes
TYPE A SROGIA
2,500 lb
2,500 lb
2,500 lb
T
60"
80" + 60"
t
60"
.I
' '
#BmLvls
3
Fy=55ksi
None
Fy=55 ksi
Fy=SS ksi
Fy=:Ss ksi
Fy=55 ksi
Fy=.36 ksi
2perBase
_Beam_Spcg
60.0 in
60.0 in
60.0in
42" .. L -------
~42",,/
frame Depthl Frame Heightl # Diagonals Beam Length I Frame Type
42in I 180.0 in I 4 96in I Single Row
Description STRESS
Hannibal If3014-3x3x14ga P=3863 lb, M=7951 in-lb 0.42-OK
None None NIA
HMH 33140/3.375~ deep x 0.075" ttlk Lu=96in I Capacity: 4282 lb/pr 0.58-OK
LvU: 3pinOK I Mconn=10023 in-lb I Mcap=16922 in-lb 0.59-OK
Hannibal H/2xl-1/2x16ga 0.2-OK
Hannibal 1-1/2xl-1/2x16ga 0.32-OK
7x5x0.375 I Fixity= 7952 in-lb 0.64-OK
0Sx3S Embed_HILTI KWIKBOI..Til ICBO ESR 1355 No Inspection (T=1439 lb) 0.49-OK
· .. s~-thkx 2000·psi slab. SOO·psf·Soil Bearing Pressure
Brace
42.0 in
42.0 in
42.0 in
42.0in
I Story force I Story Force
Traf'.ISY l.,onqit.
2301b
4601b
6901b
931b
1861b
2791b
Total: 1,380 ib 5581b
Page 4-of J~
Colu11N1
Axial
3,863 lb
2,575 lb
1,288 lb
I Column
Moment
7,951 "#
6,975 "#
4,185 "#
I Conn.
Moment
10,023 "#
8,140 "#
4,653 "#
0.95-OK
Beam
Connector
3 pin OK
3 pin OK
3 pin OK
5/1 G/200G
Srur.rurnl
· Co·nc~ts
~ l:ngi~ering -'!'J 1729 S C>011qloss Rd Ste 8 Aoobeim CA 92806 Tel· 114 456 QQ56 Eox· Zl4 456 QQ66
By: BOB Project: GIA Project#: F~041006-5
~ismic Forces Config4ration: 1YPE A SINGLE RCJN
Lateral analysis is performed with regard to sections 2228.5.2 and 1630.2 of the 2001 CBC
Ba~ shear is highest of: 1) Cv*I*W/(R*T*1.4) (EQ 30-4) <= 2.5*ca*I*W/(R*1.4) (Eq 30-5)
2) 0.11 *ca*I*W/1.4 (Eq 30-6)
3) 0,8*Z*Nv*I*W/(R*1.4) (Eq 30-7)
transverse (Ctoss Aisle) Seismic Load
4) 1.5%*(DL+LL) (Sec 2228.3.2)
T= Ct*(H)9•75 = 0.15 sec Ct-transv= 0.020
vfQ 30-4= 0.693 <= VEQ30-s= 0.1786 Vm.s3.2. = 0.015
VEQ30-6= 0.035 VEQ:30-7::;: 0.033 n-transv= 1
Base ShearCoeff= .0.1786 . Vtransv= -Base Shear Coeff * (1:DL +-:ELL/n-transv)
Level
1
2
3
LL
2,5001b
2,500 lb
2,500 lb
Longitudinal (Downaisle) Seismic Load
T=(Ct)*h"0.75= 0.27 sec .
VEQ 30-4= 0.302
VEQ30-6= 0.035
Base Shear Coeff= 0.1403
Level
1
2
3
TYPE A SROGIA
LL
2,5001b
2,500 lb
2,500 lb
= 0.1786 * (225 Jb + 7500 lb/1)
= ~,380ib
LL/(n-transv) DL
2,500 lb 75 lb
2,500 lb 75 lb
2,500·1b 75 Ill
7,500 It> 2251b
hi
60in
120in
180in
W'=77251b
Ct-long= 0.035
<= VfQ:io-s= 0.1403 V=3.2.= 0.015
wi*hi
154,500
309,000
463,500
927,000
Vlong= Base Shear Coeff * (IDL + nl./n-long)
= 0.1403 * (225 lb + 7500 lb/2)
-= 5581b
LL/(n-long) .DL
1,250 lb 75 lb
1,250 lb
1,250 lb
37501b
751b
751b
225ib
hi
60in
120in
180 in·
W=3975lb
,,,...-
Pa~e b of J't'
wi*hi
79,500
159,000
238,500
477000
I= 1.0
Seismic-Zone 4, Z= 0.4
ca= o.44
Na= 1.0
Cv= 0.64
Nv= 1.0
(Transverse) R= 4.4
Fl Fi*hi
230.0 lb
460.0 lb
690.0 lb
13,800-#
55,200·#
124,200-#
1,380 lb 1=193,200
(Longitudinal ) R= 5.6
n-long= 2
Fi
93.0 lb
186.0 lb
279.0 lb
5581b
5/1 G/200G
Ste B e1oobeim CA 928Q6 Toi· 714 456 QQ56 fox· 714 456 QQ66
By: BOB Project:. GIA
Downaisle Seismic Loads Configuration: TYPE A SINGLE ROW
Determine the story moments by applying portal analysis. The base plate is assumed to-provide partial fixity.
Seismic Story Forces
Vlong= 558 lb
vcol=Vlong/4=; 279 lb
Fl= 93, lb
F2= 186 lb
F3= 279 ib
Typical fume ma<!c
of two colomns
l I
~. -9·.--.:--a--·--··-··a··------·EE·--,·· ·13,. .. ; "I:.:-:: •.-: •• ,...... -~-.-.J ........ . . '' ",. , .. , .• ,,.~ I .......... ,. '' • ., I _,..' .
, _________ .,
Seismic Story Moments Conceptual System
Project #: F-041006-5
Typical Ftamc maclc
~oftwocolumns
Mbase-max= 8,000 in-lb <=== Default capacity
Mbase-v= (Vcol*hteff)/2
hl-eff= hl -beam dip height/2
= 57in
= 7,952 in-lb <=== Moment going to base
Mbase-eff=. Minimum of Mbase-max and. M~v
= 7,952 in-lb
M 1-1= [Vcol * h!eff]-Mbase-eff
= (279·lb * 57 in)-7952 in-lb
= 7,951 in-lb
Mseis= (Mupper+Mlower)/2
Mseis(l-1)= (7951 in'-lb + 6975 in-lb)/2
= 7,463 in-lb
LEVEL hi Axial Load
1 60in 3,863 lb
? 60in 2,575 lb
3 60in i,288 lb
TYPE A 5ROGIA
M 2~2= [Vcol-(Fl)/2] * h2
= [279 lb -93 lb]*60 in/2
= 6,975 in-lb
Mseis(2-2)= (6975 in-lb+ 4185 in-lb)/2
· = 5,580 in-lb
S"inmarf of F~
Column Moment Mseismic Mend-fixity
7,951 in-lb 7,463 in-lb 2,560 in-lb
6,975 in-lb 5,580 in-lb 2,560 in-lb
4,185in-lb 2,093 in-lb 2,560 in-lb
Paf:3e (p of \ 'l-
h1 h1eff
11
Beam to Column Elevation
Mconn Beam Connector
10,023in-lb 3 pin OK
8,140 in-lb 3 pin OK
4,653 in-lb 3 pin OK
5/1 G/200G
By_: BOB Project: GIA Project#: F-041006-5
Column Configuration: TYPE A SINGLE RCJW
Conforms to the requirements of Chapter CS of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads.
Section, Properties
Section: Hannibal IBJ143x3x14ga
Kx= 1.2
3.000in
Aeff-= 0.643 inA2
Ix= 1.f3Q jnA4
Sx = 0.753 inA3
rx = 1.326 in
nf= 1.67
Iy '= 0.749 inA4
Sy= 0.493'inA3
fy= 1.080 in
Fy= 55 ksi
Cmx= 0.85
Lx = 60.0 in
Ky= 1.0
Ly= 42.0 in
Cb= 1.0
y----;-----y
I0.075 in
ii: _J__
E= 29,500 ksi
Loads
Axial=P= 3,863 lb
Axial Analysis
.Kxlx/rx = 1.2*60"/1.326"
= 54.3
_Fe= nA2E/(Kl./r)maxA2
= 98.Sksi
Pn= Aeff*Fn
= 30,441 lb
P/Pa= 0.24
Bending Analysis
Moment=Mx= 7,951 in-lb
> 0.15
Kyly/ry = 1*42"/1.08"
= 38.9
Fy/2= 27.5 ksi
Qc= 1.92
Check: P/Pa + (Cmx*Mx)/(Max*µx) s 1.33
P/Pao + Mx/Max.:. 1.33
Pno= Ae*Fy
'=3-o.75in
{Column stresses @ Level 1)
Pao= Pno/Qc
Fe> Fy/2
Fn= Fy(1-Fy/4Fe)
= 55 ksi*[l-55 ksi/(4*98.8 ksi)]
= 47.3 ksi
Pa= Pn/Qc
= 30441 lb/1.92
= 15,855 lb
Myield=My= Sx*Fy
= 0.643 jnA2 *55000 psi
= 35,365 lb
= 353651b/1.92
= 18,419 lb
= 0.753 inA3 * 55000 psi
= 41,415 in-lb
Max= My/Qf
= 41415 in-lb/1.67
= 24,799 in-lb
µx= {l/[l-(Qc*P/Pcr)]}A-1
= {lf[l-(1.92*3863 lb/63465 lb)]}"-1
= 0:88
Combined Stresses
Per= nA2EI/(KL)maxA2
= nA2*29500 ksi/(l.2*60 in)A2
= 63,465 lb
(3863 lb/15855 lb)+ (0.85*7951 in-lb)/(24799 in-lb*0.88) =
(3863 lb/18419 lb) + (7951 in-lb/24799 in-lb) =
0.55
0.53
< 1.33, OK
< 1.33, OK
TYPE A SROGIA Paqe (J-,\of J 'r"
(EQ C5-1)
(EQ C5-2)
5/1 G/200G
Str~ur~I
VonE,ts ~--?7 . · ngineering .
. ~ . 1729 S. Douglass R~. Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066
8y: BOB.S. Project: GIA Project #: F-041006-5
Column-E?(po~d Post Check
Conforms to the requirements of Chapter CS of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads.
Check post protector requirement of 2001 CBC Sec 2222.5
Section Properties
Loads
Section: 3x3x14 ga
Aeff = 0.643 in/\2
Ix= 1.130 in/\4
Sx = 0.753 in/\3
rx = 1.326in
Qf= 1.67
E= 29,500 ksi
Axial=P= 3;863 lb
Axial Analysis
Kxlx/rx = 1.7*60"/1.326"
= 76.9
Fe= nA2E/(KL/r)maxA2
= 49.2ksi
Pn= Aeff*Fn
= 25,482 lb
iy = 0.749 in/\4
Sy= 0.493 in/\3
ry= 1.080 in
Fy= 55 ksi
Cmx= 0.85
width= 3.000 in
.d!!pth1= 3.000 in
thick1= 0.075 in
Moment=Mx= O·in-lb
Kyly/ry = l*42"/1.08"
· = 38.9
Fy/2= 27.5 ksi
Qc= 1.92
P/Pa= 0.29 > 0.15
Bending Analysis
Check: P/Pa + (Cmx*Mx)/(Max*µx) :5 1.33
P/Pao + Mx/Max :5 1.33
Pno= Ae'*Fy
= 0.643 in/\2 *55000 psi
= 35,365 lb
Max= My/Qf
= 41415 in-lb/1.67
= 24,799 in-lb
µx= {1/[1-(Qc*P/Pcr)J}A-1
Combined Stresses
= {1/[1-(1.92*3863 lb/31623 lb)]}A-1
= 0.77
Kx = 1.7
Lx = 60.0 in
Ky= 1.0
Ly= 42.0 in
Cb= 1.0
Fe> Fy/2
Fn= Fy(1-Fy/4Fe)
r-3.000in-o-j Rf;n
~ ~ 0.75in
= 55 ksi*[i-55 ksi/(4*49.2 ksi)]
= 39.6 ksi
Pc:1= Pn/Qc
= 25482 lb/1.92
= 13,272 lb
Pao= Pno/Qc Myield=My= Sx*Fy
= 353651b/1.92
= 18,419 lb
Per= nA2EI/(KL)max/\2
= n/\2*29500 ksi/(1.7*60 in)A2
= 31,623 lb
= 0.753 inA3 * 55000 psi
= 41,415 in-lb
(3863 lb/13272 lb) + (0.85*0 in-lb)/(24799 in-lb*0.77) =
(3863 lb/18419 lb)+ (0 in-ll;l/24799 in-lb)=
0.29
0.21
< 50%, OK per sec. 2222.5
No Post Protector Required
· Str~ur~I .
vonca!£lts $.if Cngineering ~ 1125 S. Douglass Rd, Ste D Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066
By:B085 . Project: GIA Project#: F-041006-5
. umn
Conforms to the requirements of Chapter CS of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads.
Section Properties
Section: 3X3X14GA.
Aeff = 0.643 inA2
Jx = 1.130 inA4
Sx = 0.753 inA3
rx = 1.326 in
.Qf= 1.67
E= 29,500 ksi
Cb= 1.0
Iy = 0.749 inA4
Sy= 0.493 inA3
ry = 1.080 in
Fy= 55ksi
J_ My
Cmx= 0.85
width= 3.000 in
depthl= 3.000 in
thick!= 0.075 in
lx = 60.0 in
Ly= 42.0 in
~ ~ 0.075m
Transverse Elevation
Loads
Movt= 222,180 in-lb
Frame Depth= 42 in
Seis)nic Axial=Pv= Movt/d
= 5,290 lb'
Axial Analysis
Kxllc/rx = 1.2*60"/1.326"
== 54.3
Fe= nA2E/(Kl./r)maxA2
= 98.8ksi
Pn= Aeff*Fn
= 30,441 lb
P/Pa= 0.58
Bending Analysis
> 0.15
Check: P/Pa + (Cmy*My)/(May*µy) :s; 1.33
P/Pao + My/May :s; 1.33
Pno= Ae*Fy
Static; Axial=Ps= 3,863 lb
ptotal=P= 9,153 lb
Kyly/ry = 1 *42"/1.08"
= 38.9
Fy/2= 27.5 ksi
Qc= 1.92
Pao= Pno/Qc
V= 1,380 lb
h= 6 in
Moment=My= V*h
= 8,280 in-lb
Fe> Fy/2
Fn= Fy(1-Fy/4Fe)
= 55 ksi*[l-55 ksi/(4*98.8 ksi)]
= 47.3 ksi
Pa= Pn/Qc
= 30441 lb/l.92
= 15,855 lb
Myield=My= Sy*Fy
h
= 0.643 in"2 *55000 psi
= 35,365 lb
;:: 353651b/1.92
= 18,419 lb
= 0.493 in"3 * 55000 psi
= 27,115 in-lb
May= My/.Qf
= 27115 in-lb/1.67
= 16,237 in-lb
µx= {l/[1·(.Qc*P/Pcr)]}"-1
Combined Stresses
= {1/[1-(1.92*9153 lb/63465 lb}]}"··l
= 0.72
Per= n"2El/(KL)max"2
= n"2*29500 ksi/(l.2*60 in)"2
= 63,465 lb
(9153 lb/15855 lb) + (0.85*8280 in-lb)/(16237 in-lb*0.72) =
(9153 lb/18419 lb)+ (8280 in-lb/16237 in-lb) =
1.18
1.01
< 1.33, OK
< 1.33, OK
Page 7. ~ of Ir
(EQ CS-1)
(EQ CS-2)
By: BOB Project: GIA Project#: F-041006-5
Beam Cpnfigurat;ion: TYPE A SJ;NGLE ROVI/
The beam to column connection is assumed to provide partial ~ fixity for the bearJ) frame. The end moment calculated herein is added
to the lateralforce force portal moment when analyzing.the connection capacity. Designed per section 2228 of the 2001 CBC
The impact foad,on the beam is addressed by including the Impact Factor "a" in the determination of the beam center bending stress.
Sed:ion Properties
Beam Member= HMH 33140/3.375" deep x 0.075" tl\k tl.750in {
t--2.750ini,T,
Beam at Level= 1
Beam Type= Formed
Ix= 1.337 in"4
Sx= 0.750 in"3
Lerigth=L= 96.0 in
LU= 96.0in
Beam W~ght= 4.0 lb/ft
Thickn~= 0.075 in
Beam Shaj)e= Step
T ... ,.,.
3,375in -,L
Impact Factor (a)=tl-(25%/2)]= 0.875 1 0,075in
~ Loads
Bendin
% End Fixity= 25 %
0= 0.25
Mcenter= B*(wL "'2/8}
= 0.832*(wlA2/8)
Mends= 0*Mmax(fixed ends)
= (wLA2/12)*0.25
= 0,02Q8*wl A2
Fb= 0.6* Fy
= 33,000 psi
Fb-eff= 33,ooo psi
Uve Load/Pair=;: 2.,500 lb
Mcenter= 0.104 * wLA2
= 12,799-in-lb
M= 12,799 in-lb
fb= (M/Sx)/a
= 19,504psi
Bending capcity= 4,282 lb/pair .
Deflection
Defl-allow=L/ 180
= 0.534in
Deflection capacity= 4i310 lb/Pair
CoeffB= 0.104/0.125
= 0,832
Mcenter= Mcenter(simple ends)-0*Mcenter(fixed ends)
= wLN/8 -(0.25 * wL "2/12)
=wl"2/8 -wL"2/48
= 0.1(}4 * wl A2
Fy= 55,000 psi
Dead Load/Pair= ( 4 lbffl:) * 2 * 96 in/12
= 641b
Mends= 0.0208*wl"2
= 2,560 in-lb
fb/F!>= 19504 psi/33000 psi
= 0.59 <= 1.0, OK
<=== ·Critical
Defl= B * [SwL A4/(384*E*Ix)]
Dist Load=w= 13.4 lb/in
= [5*13.4 lb/in*(96 in)"4/(384*29.5x10"6 psi * 1.337 in"4)]*0.832
= . 0.313 .in . <= 0.534 in, OK
Allowable load per beam pair= 4,282 lb
TYPE A SROGIA 5/1 G/200G
Ste B Anaheim CA 92806 Tel: 714 456 0056 fox: 714 456 0066
By: BOB. Project:. GIA
3 Pin Beam to Column Connec:tion 1YPE A SINGLE ROW
Mconn max= 10,023 in-lb Load at level 1
Connector Type= 3 Pin
Shear·capacity of Pin
Pin Dii;lm= 0.44 in Fy= 55,000,psi
Ashear= (0.438 in)A2 * Pi/4
= Q.15Q]'jnA2
Pshear= 0.4 * Fy * Ashear
= 0.4 * 55000 psi* 0.1507in-":-2
= 3,315 lb
Bearing capacity of Pin
Per ffiei996 AISI Cold Formed Steel Manual, Sec B.3:
teal= 0.075 in
Omega= 2.22
Fu= 65,000 psi
a= 2.22
Pbearing= -alpha * Fu "' diam * tcbl/Omega = 2.22·* 65000 psi* 0.438 in.* 0.075 in/2;22
= 2,135 lb < 3315 lb
Momerit ~pacity of Bracket
Edge Distance=E= 1.00 in Pin Spacing= 2.0 in
C= Pl+P2+P3 tclip= 0.18 in
= Pl +Pl *(2.5"/4.S")+Pl *(0.5" /4.5")
= 1.667* Pl .
Mcap= Sclip * Alending
= 0.127 jnA3 * 0.66 * Fy
= 4,610 in-lb
Pclip= Mcap/(1,667 * d)
C*d= Mcap = 1.667
= 4610.1 in-lb/(1.667 * 0.5 in) = :s,531 lb
Thus, Pi= 2,135 lb
Mconn-allow= [Pl *4.S"+Pl *(2.5"/4.5")*2.S"+Pl *(0.5"/4.5")*0.5"]*1.33
= 2135'LB*[4.5"+(2.5"/4.5")*2.5"+ (0.5"/4.5")*0.5"]*1.33
= 16,922 in-ID > Mconn max, OK
lYFE A 5ROGIA Pa,ae 9 of I '1-
Project #: F-041006-5
Fy= 55,000 psi
Sc(ip= 0.127 inA3
d= E/2
= 0.50 in
5/1 G/200G
~rnl
· C~nc~ts
-~ t:ngineering ~ l 129 s J)ouqloss Rd Ste B 4oobeirn CA 928D6 Iel · Zl 4 456 0056 Eox· Zl 4 456 0066
By: 808 Project: GIA Project #: F-041006-5
Tran!iverse Brace Configuration: TYPE A SINGLE ROW
Section Properties
Diagonal Member= Hannibal 1-1/2xl-l/2x:16ga
Area= 0.273 inA2
r min= 0.496 in
Fy= 55,000 .psi
K= 1.0
r-1.500-,
Horizontal Member= Hannibal 1-1/2x:1-1/2x:16ga
Area= 0,273 jnA2
r min= 0.496 in
Qc= 1.92
Fy= 55,000 psi
K= 1.0 n i 100
~ /--0.25 .
Frame Dimensions
Bottom Panel Height=H= 42.0 in
Frame Depth=D= 42.0 in
Column Width=B= 3.0 in
Diagonal Member
V=Vtransv= 1.,380 lb
Ldiag= [(D-B*2)A2 + (H-6.)"'•2JA1/2
= 50.9in
Pmax= V*(Ldiag/D}
= 1,672 lb
Pn= ARl;A*Fri
= 0.273 jnA2 * 27657 psj
= 7,550 lb
Pallow= Pn/Q
= 7550 lb /1.92
= 3,932 lb
fa/Fa= , 0.43
Horizontal brace
Pmax=V= 1,380 lb
, (kl/r)= (k * Lhoriz)/r min
= (1 x 42 in) /0.496 in
= 84.7in
SINCE Fe>Fy/2, Fn=Fy*(l-fy/4fe)
= 36,366 psi
fa/Fa= 0.27
lYFE A SROGIA
<= 1.33 OK
<= 1.33 OK
aear Depth=D-8*2= 36.0 in
XBrace= NO
SINCE Fe>Fy/2,
(kl/r)= (k * Ldiag)/r min
= (1 x 50.9 in /0.496 in )
= 102.6in
fe= piA2*E/(kl/r)A2
= 27,658psi
Fn= Fy*(l-fy/4fe)
= 27,657 psi
T
!::====::::11
fe= piA2*E/(ld/r)A2
= 40,584~psi
Pn= AREA*Fn
: Q,273inA2*36366 psi
= 9,928 lb
Paqe {D of j '1-
B #
Check End Weld
Lweld= 2.5 in
Fu= 65 ksi
tmin= 0.060 in
Typical Panel
Configuration
Weld capacity= 0.75 * tmin * L * Fu * 1.33/2.5
3,900 lb OK
Fy/2= 27,500 psi
Pallow= Pn/Qc
= 9928 lb /1.92
= 5,171 lb
5/l G/200G
CA 92806 Iel· 714 456 Q056 fox· Zl4 456 Q066
By: BOB · Project: GIA Project #: F-041006-5
Anchors Configuration: TYPE A SINGLE ROW_
Ch~k overturning per section 2228.7.1 of the 2001 CBC
· Loads
Vtrans=V= 1,380 lb
DI./Frarne= 225 lb
Ll/Frarne= 7,500 lb
Wst=(0.9*DL+Ll/n)total= 7,703 lb
Ii@ TOP= 2,500 lb
DL/Lvf= 75 lb
Frame Depth=D= 42.0 in
Htop-lvf= 180.0 in
# Levels= 3
n-transv= 1
DL *0.90= 68 lb # Anchors/Base= 2
n= 1
T
Lateral Ovt Forces=:E(Fi*hi)= 193,200 in~lb
Fully Loaded rack SIDE ELEVATION
\/trans= 1,380 lb
Movt= I(R*hi)*l.15 Mst= Wst * D/2 T = (Movt-Mst)/D
= 193200in-lb * 1.15
= 222,180 in-lb
= 7702.5 lb * 42 in/2
= 161,753 in-lb
= (222180 in-lb -161753 in-lb)/42 in
= 1,439 lb
Top Level Loaded Only
Critical Level= 3
Anchor
· Vtop= 2.5*Ce*I(0L +lL@top/n-transv)/(R*1.4)
= 0.1786 * (75 lb + 2500 lb/1)
= 4601b
Mst= 0.9*(DL-total + Utop/n) *D/2
= (250Q lb/1 + 67.5 lb*3) * 42 in/2
= 56,753 in-lb
Hgt @ Lvf 3= 180.0 in
Movt= Vtop*Htop*l.15
= 459.895 lb * 180 in * 1.15
= 95,198 in-lb
T = {Movt-Mst)/D
= (95198 in-lb -56753 in-lb)/42 in
= 9151b
Check (2) 0,5" x 3.5" Embed HJ;LTI KWIK BOLT II anchor(s) per base plate.
Special inspection is not provided per ICBO ESR 1355.
Fully Lqaded:
Top l:.evel Loaded:
TYPE A SROGIA
Pullout capacity= Tcap= 875 lb
Shear Cepacity=Vcap= 1,840 lb
· Tcap*Phi*S= 1,164 lb
Vcap*Phi*S= 2,447 lb
L.A. Qty Jurisdiction? NO
Phi= 1.33
Spacing Coeff=S= 1.0
(720 lb/1164 lb)"l.66 + (345 lbl2447 lb)"1.66 =
(458 lb/1164 lb)"1;66 + (115 lb/2447 lb)"l.66 =
f'aqe I \ of ) r}
0.49
0.22
<= 1.0 OK
<= 1.0 OK
5/IG/200G
CA 92806 Tel· 714 456 0056 Eax-714 456 0066
By: BOB Project: GIA
Base Plate Configuration: 1YPE A SINGLE ROW
Section
Baseplate= 7 x 5 x 0.375
Eff Width=W = 7.00 in
EffDepth=D = 5.00 in
Column Width=b = 3.00 in
Column Depth=dc = 3.00 in
a= 2.50 in
Anchor c.c. =2*a=d = 5.00 in
N=# Anchor/Base= 2
Py = 36,000 psi
L= 2.00 in
Plate Thickness=t = 0.~75 in
Down Aisle Loads
P = 3,863 lb Mbase=Mb = 7,952 in-lb
Axial stress=fa = P/A = P/{D*W)
= 110 psi
Moment Stress=fb = M/S = 6*Mb/[(D*BA2]
= 194.7psi
Moment Stress=fbl = fb-fb2
= 83.Spsi
M3,,;, (1/2)*fb2*L*(2/3)*L = (1/3)*fb2*LA2
= 148 in-lb
$-p]ate = (1)(tA2)/6
= 0.023 inA 3/in
fb/Fb = Mtotal/[(S-plate)(Fb)]
= 0.64 OK
Tanchor = (Mb-(P*0.9)(a))/[(d)*N/2J
= -148 lb No Tension
TYPE A SROGIA
Ml= wl.A 2/2= fa*L" 2/2
= 221 in-lb
Moment Stress=fb2 = 2 * fb * l.jW
= 111.3 psi
M2= fbl*l:/'2)/2
= 167 i.n-lb
Mtotal = M~+M2+M3
= 536 in-lb/in
Fb = 0.75*Fy*1.33
= 35,910 psi
Tallow= 1,164 lb
f'aqe \t-~f {q-
Project #: F-041006-5
Downaisle Elevation
OK
5/ I G/200G
5-trur,tural
· Conc~ts
· -~ Cngineering .
~-lZ29 S Do11qloss Qd Ste B 4oobeim C4 92806 :tel· Zl4 456 0056 Eox· 114 456 QQ66
By:. BOB Project: GIA Project #: F-041006-5
Slab on Grade Configuration: TYPE A SINGLE ROW
Toe slab is· designed per UBC 1922 to carry the punq:u~ stress of the post as-well as the upward soil reaction from the soil.
SLAB ELEVATION
Base.Plate
B::; 7.00 in
D= 5.00 in
Load case 1: Product + Seismic
Product DL= 113 11:i
Product LL= 3,750 lb
Puncture !Section 1922.51 Eqtn 22-9
width=a= 3.00 in
depth=b= 3.00 in
'Baseplate Plan View
Concrete
fc= 21000 psi
tslab=t= 5.0 in
phi=0= 0.65
eff, baseplate width=c= 7.00 in
eff. baseplate clepth=e= 5.00 in
p:seismic=E= (Movt/Frame depth)*l.4
= 7,406 lb
Pse=DL+LL+E/1.4= 91153.lb
(Strength Design Loads)
Pu= l.1*(1.2PDL + 1.0PLL + 1.0*E) (Sec 1612.2.11 EQ 12-5) Fpunct= 2.66*phi*sqrt(fc)
·--. -··--··· _ .. = 12/420 lb_ _ .. _ --• -••--n • • ·---••••·--•-.n ~ -----~-----·----
Apunct= [(c+t)+(~+t)]*2:!:t
= 220.0 in"2
Slab Bending !Per UBC 1922.7.2
Asoil= (Pse*144)/(fsoil) L= (Asoil)"0.5
=· 2,636 in"2 = 51.34in
x= (l.:-y)/2 M= w*x"2/2
= 17.7 in = (fsoil*x"2)/(144*2)
Fb= S*(phi)*(fc)"0.5/1.4 = 544.7 in-lb
:= 104.0 psi (Sec 1922,~.1)
Load case 2: Static Loads
PDL= 1131b PLL= 3,750 lb
Puncture !Section 1922.5, Eqtn 22-9
Pu= !.4*PDL + 1.7*PU. (Sec 1909.2.1, EQ 9'-1)
= 6,5331b
Apunct= [(c+t)+(e+t)]*;?.*t
= 220 in"2
Slab Bending !Per UBC 1922.7.2
Asoil= (Ps*144)/(fsoil) L= (Asoil)"0.5
= 1r112·in"2 = 33.35 in
x= (L-y)/2 M= w*x"2/2
= 8.7in = (fsoil*x"2)/(144'*2)
Fb= S*(phi}"(fc)"0.5/.1.7 = 132.0 in-lb
= 85.0 psi (Sec 1922.5.1)
...... --·----=-77.3 ~--·--· . ·-..
fv/Fv= Pu/(Apunct*Fpunct)
= 0.73 < 1.33 OK
y= (c*e)"'0.5 + t*2
= 15.9in
S-slab= 1 *t" 2/6
= 4.17 in"3
fb/Fb= M/(S-slab*Fb)
= 1.257
Ps= DL+LL
= 3,863 lb
< 1.33,0K
Fpunct= 2.66*phi*sqrt(fc)
= 77.3 psi
fv/Fv= Pu/(Apunct*Fpunct)
= 0.38 < 1.00K
y=· (c*e)A0.5 + t*2
= 15.9 in
S-slab= 1*t"2/6
= 4.17 in"3
fb/Fb= M/(S-slab*AJ)
= o.;;73 < 1.0,0K
TYPE A.SROGIA F'aqe l ~ of ) q., 5/IG/200G
--
I
CA 928Q6 Iel· 714 456 QQ56 Fox· 714 456 QQ66
By: BOB Project: . GIA Project #: F-041006-5
Configuration & Summary: TYPE A. DOUBLE ROW
Seismic Zone
4(Na=l.0)
Tlong=0.27 sec/ Tshort=0,15 sec ,
Component
Column.
Column· Backer
Beam
Beam q>nnector
Brace.:Hortzontal
. B~e-Di~al
Base Plate
Anchor
Level
J
2
3
No~
Slab I Load
. PerLevel
3,;200 lb
3,200-lb
3,200 lb
TYPE I DROGIA
.
' T T
60tt
+ 180" 60"
t
42" + ~, 42" + 180"
42" + 60" 42"
I L
' '---r--96" ~ _}.--42" ~ -+-42" ,r
# Bmlvls
3
Fy=55 ksi
None
Fy=55ksi
Fy=55ksi
Fy=S~~i
Fy=55 kst
Fy=36 ksi
2~Base
BeamSpcg
6().0 in
60.0in
60.0in
Frame DepthjFrame Height! # Diagonals Beam Length I Frame Type
42in I 180.0 in I 4 96in I Intrconnected
Description
Hannibal IF3014-3x3x14ga P=4913 lb, M=12093 in-lb
None None
HMH 33140/3.~75" deep x 0.075" thk Lu=96in I Capacity: 42881b/pr
Lvl i: 3 pin OK I Mconn=l3?12 in-lb I Mcap=16922 in-lb
Hannibal 1-l/2xl-l/2x16ga
·Hcjnnibal 1-l/2xl-1/2x16ga
7x_Sx0.375 I Rxity= 8000 in-lb
0.5" x 3S Embed tfiLTI KWIKBOLTII ICBO ESR 1355 No Inspection (T=O lb)
s· ttikx 2900 ~i slab, 500· psf Soil Bearing Pressure
Brace
42.0in
42.0in
42.0 ii!
42.0in
T~I:
I Story Force . I Story Force
Tra~ . Longit.
1501b
2991b
4491b
8970;>
1181b
2351b
3531b
7051b
Column
Axial
4,913 lb
3,275 lb
1,638 lb
I Column I
Moment
12,093 "#
8,813 "#
5,288 "#
Conn.
Moment
13,712 "#
10,309 "#
5,903 "#
STRESS
0.6-0K
N/A
0.75-0K
0.81-0K
0.13-0K
0.21-0K
0.71-0K
0.02-0K
0.83-0K
Beam
Connector
3 pin OK
3 pin OK
3 pin OK
Pat3e \4 of \r:} 5/IG/200G
5-trur.:turol
· .Conc;e,ts
· ~~ Cngineering .
'~ . 1729 S Douglass Rd Ste 8 Aoobeim CA 928Q6 Tel· 714 456 0056 Fox-714 456 QQ66
By:. BOB Project: GIA Project#: F-041006-5
Configura1;ion & Summary: TYPE B DOUBLE ROW
Seismic Zone
4 (~a=1.0) ·
Tio~g=0.27sec I Tshort=0.15 sec
''
. Compon~t
Column
Col_umh Backer
Beam
Bean:i Connector
Brace-Horizontal
. Brare-Diagonal
Base Plate·
Anchor
Slab
Level
·1Pe':.::e1
1
2
3
4
1,0QO lb
· 3,2001b
3,200 lb
3,200 lb
.Notes 'l
TYPE B DROGIA
. ' T
60"
t
60"
180" t-
30"
+
30"
' J
' '
#Bmlvls
4
Fy,=55 ks!
Nooe
Fy=55 ksi
Fy=55 ksi
Fy=SS ksi
Fy=55ksi
Fy=36 ksi
2perBase
BeamSpcg
30.0in
30.0in
60.0in
60.0in
.. ' 42" + 42"
180" + 42"
.. t '\,,
42" ~-_,l__
}-42"~--f-42"--;f'
Frame Depth! Frame Height! # Diagonals Beam Length I Frame Type
·42.in L 180;Q in I 4 96in I Intrconnected
Description
Hanoil:lal IBJ14-3x3x14g~ P=3275 lb, M=9551 in-lb
None None
HMH 33140/3.375" deep x 0.075" thk. Lu=96in I capacity: 41921b/pr
Lvl 1: 3 pin OK_ I Mconn=5850 in-lb I Mcap=16922 in-lb
Jjannibal H/2xl-1/2x16ga
fianniQal 1:-1/2xl-1/2x16ga
7 x_ 5. x o_.375 I Rxity= 5306 in-lb
0.5" x 3,5" Embed HILTI KWIK BOLT II ICBO ESR 1355 No Inspection (f=O lb)
s· thk x 2000 psi slab. 500 psf Soil Bearing Pressure
Brace
42.0in
42.0in
42.0in
42.0in
Total:
I Story force I ~ry F~
. Tran~ Long1t.
28lb
1621b
324·1b
4861b
1,000-lb
221b
1271b
2551b
~21b
7861b
Column
Axial
5,450 lb
4,913 lb
3,275 lb
1,638 lb
I Column
Moment
5,305 "#
5,731 "#
9,551 "#
5,730 "#
I Conn.
Moment
5,850 "#
8,703 "#
8,702 "#
3,927 "#
STRESS
0.43-0K
N/A
0.24-0K
0.35-0K
0.15-0K
0.23-0K
0.62-0K
0.02-0K
0.95-0K
Beam
Connector
3 pin OK
3 pin OK
3 pin OK
3 pin OK
5/1 G/200G
I
1
Strur.:tural
.C~nc~ts
·;;.~ l:ngineering ~ 1729 S Douglass Rd Ste B 4nobeim CA 92806 IeF 714 456 QQ56 fox· 714 456 QQ66
By: BOB Project: _ GIA-Project#: F-041006-5
Configuration & Summary: TYPE C DOUBLE ROW
T
60"
180" + 60"
t
60"
.I
'-
, r
Seism,ic Zone #BmLV,s_
4 (Na=l.0) 3
Tlong=0.27 sec/ Tshort=0.15 sec
Component
Column Fy=55 ksi
Column Back~r None
Beam Fy=55 ksi
Beam Connector Fy=55 ksi
Brace-Horizontal Fy=55 ksi
Bra~pjagonal Fy=55.ksi
Base Plate Fy=36ksi
Anchor .2 per·Base
Slab ..
Level . , Load
Per Level BeamSpcg
3 2,500 lb 60.0in
Notes
TYPE. C DROGIA
T
,42"
180"
+ ,______. +/
42" t.__l
42" + !'---l
78" _}.-42" --,,j--_}-42·· -,t
Frame,~fFrame ~g~I-# Diagonals Beam Length I Frame Type
42in L 18Q.Oin .J 4 78in I Intrconnected ..
Description
Hannibal_~F3Qi4-~1~ P=2963 lb, M=6142 in-lb
~OnE:! None
HMH 33FJOi3.375• _deep-x,O.Q75" thk Lu=78in I capacity: 5265 lb/pr
Lvl 3: 3 pin OK ·1 Mi::onn=4017 in-lb I Mcap=16922 in-lb
Hannibal 1-1/2x1-1/2x16ga
~nnibal 1-1/2xl-1/2x16ga
7x5.,c0.375 I Rxity= 6142 in-lb
0.5" x 3.5" !:mbed HILT! !(WIK BOLT![ ICBOESR 1355 No Inspection (T=O lb)
s·-thk_x,?QOO psi slab. 500 psfSoil Bearing Pressure
Brace
42.0in
42.0in
I s~ Force J Story Force
Trans.v . Longit
3311b 2601b
Tal:Ql: . 549 lb 4311b
Column I Axial
1,2881b
Column I Conn.
Moment Moment
3,894 "# 4,017 "#
STRESS
0.31-0K
N/A
0.47-0K
0.24-0K
0.08-0K
0.13-0K
0.49-0K
O.Ql-OK
0.39-0K
Beam
Connector -.
3 pin OK
5/1 G/200G
I
~
Struc;tural
· Conc,e_ts
· ~ Cngineering :-V 1729 S t:>011gloss Rd Ste B 4oobeim CA 92806 Toi· 714 456 QQ56 Eox· 714 456 QQ66
By: BOB Project: GIA Project #: f-041006-5
Configuration & Summary: TYPE D S.INGLE ROW
Seismic Zone
4(Na=1.0)
Tlong=0,77 sec/ Tshort=O;lS sec
. Component
· Column
Column BackE:!.r
Beam
Beam Connector
Brace-Horizontal
Brace-Diagonal
Base Plate
Anchor
Level
1
i
3
.
Notes
Slab
IPe~el
2,500 lb
· 2,500 lb
2,5001b
TYPE D SROGIA
T
60"
180"
f.·
60"
t
60"
J.
' '
#BmLYls
3
fy=SS~i
None
Fy=S5 ksi.
Fy=55 ksi.
Fy=55 ksi
Fy:;::55ksi .
Fy=36ksi
2per~
BeamSpcg
60.0in
60.0in
60.0in
T
42"
. + / 42"
180" + 42" ... + 42"
L-
~42"~
.f.rame Depthf Frame Height!.# Oiago11als Beam Length I Frame Type
42in I 180.0 in L 4 78in I Single Row
Oes~ription STRESS
· Hanniba.f IF3014-3x3x14ga P=3863 lb, M=7951 in-lb 0.42-0K
None None N/A
. HMH 33140/3.375" deep x 0.075" thk I..u=78in I capacity: 52651b/pr 0.47-0K
Lvl 1: 3 pin OK I Mconn=9533 in-lb I Mcap=16922 in-lb 0.56-0K
'. Hannibal 1-1/2xl-1/2x16ga 0.2-0K
1-fannibal 1-1/,4Xl-1/2x16ga 0.32-0K
7x5x!),375 I Rxity= 7952 in-lb 0.64-0K
0.5" x 3.5" Embed HILTI KWIK BOLT II ICBO ESR 1355 No Inspection (T=1439 lb) 0.49-0K
s· thk x 2000 psi·slab. 500 psf Soil_Bearing Pressure
Brace·
42.0in
42,0 in
42.0in
42.0in
·1 5tory·Force I Story Force
· Tra.nsv Longit-.
2301b
4601b
6901b
931b
1861b
2791b
Total,: 1,380 lb 5581b
rage l<7 of 1'1
Column
Axial
3,863 lb
2,575 lb
1,288 lb
I Column
Moment
7,951 "#
6,975 "#
4,185 "#
I Conn.
Moment
9,533 "#
7,650 "#
4,163 "#
0.95-0K eeam
Connector
3 pin OK
3 pin OK
3 pin OK
5/1 G/200G ·_J