Loading...
HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; ; CB072325; Permit10-26-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB072325 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1950 CAMINO VIDA ROBLE CBAD Tl Sub Type 2120931200 Lot# $190 855 00 Construction Type Reference # CBAD CORP CENTER 5453 SF Tl LOBBY & CORRIDORS ONLY INDUST 0 VN Applicant KIMBERLY BOWERS STE 400 1510 FRONT ST SAN DIEGO CA 92101 619702 0380 Status Applied Entered By Plan Approved Issued Inspect Area Plan Check# Owner CARLSBAD CC L P C/0 MATTHEW J ROOT 10188TELESISCT#222 SAN DIEGO CA 92121 ISSUED 09/06/2007 RMA 10/26/2007 10/26/2007 Building Permit Add I Building Permit Fee Plan Check Add I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add I Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add I Pot Water Con Fee Reel Water Con Fee $902 01 Meter Size $0 00 Add I Reel Water Con Fee $586 31 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $4008 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $000 Traffic Impact Fee (4305541) $000 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $000 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $2000 $000 $000 $000 $000 $000 99 $1 548 40 Total Fees $1 548 40 Total Payments To Date $1 548 40 Balance Due $000 BULLUiNU FLANS * IN STORAGE ATTACHED v UL Inspector^ FINAL APPROVAL /s^ui NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing m accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave, Carlsbad CA 92008 FOR OFFICE USE O PLAN CHECK NO EST VAL Plan Ck Deposit Validated, Date j » / f JT !&. -•>"—* ^ /VfebaJ. /fA fcOO?^60 O^mtno ifla. Eo Address (include Bldg/Surte #) r\Lol -&24-S& o\s Name (at tliis address)untf Lot No Subdivision Name/Number .I ExistlngUseIII .«....,-bWd gffc. liih-kn*. WftL. / SQ FT A 'ft (J^ ^ofStooles City ' State/Zip ' U telephones (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct .alter improve demolish or repair any structure prior to Its Issuance Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penally of not more than five hundred dollars [SEOO]) Name State License # Designer Name State License # 6 ,(JggSl||§0MP! Address License Class Address « T t jr City City State/Zip City Business License # State/Zip Telephone # Telephone # Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations D I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued D I have and will maintain worker's compensation as required by Section 3700 of the labor Code for the performance of the work for which this permit Is issued My worker's compensation insurance earner and policy number are Insurance Company Policy No Expiration Dale (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit Is Issued I shall rot employ any person In any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage Is unlawful and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars{$100 000) in addition to the cost of compensation damages are provided for In Section 3706 of the Labor Code Interest and attorney s fees SIGNATURE DATE 7 •> I hereby affirm that I am exempt from the Contractor's License Law for the following reason D I as owner of the property or my employees with wages as their sole compensation will d the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Conlractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such Improvements are not Intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) D I as owner of the property am exclusively contracting with licensed contractors to construct the project (Ssc 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with conlractor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D YES D NO 2 I (have/have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / /ontractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work) PROPERTY OWNER SIGNATURE f\~lAA£ WHITE File YELLOW Applicant PINK Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave Carlsbad CA 92008 Page 2 of 2 is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration for or nsk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Acf D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncf D YES D NO Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' D YES D NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT •«OllLRUCTION LENDIIf I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code) LENDER S NAME LENDERS ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGEMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations of 5 0 deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 jtoys (Section 1p6 4 4 Uniform Building Code) -^APPLICANT S SIGNATURE S~f&&01i&&l?f7 ^-SC^rf^l; DATE WHITE File YELLOW Applicant PINK Finance City of Carlsbad Bldg Inspection Request For 01/17/2008 Permit# CB072325 Title CBAD CORP CENTER 5453 SF Tl Description LOBBY & CORRIDORS ONLY Inspector Assignment RB Type Tl Sub Type INDUS! 1950 CAMINOVIDAROBLE Lot 0 Job Address Suite Location OWNER CARLSBAD CC L P Owner CARLSBAD CC L P Remarks Phone 8589975829 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By JOE Entered By JANEAN Act Comment Comments/Notices/Holds Associated PCRs/CVs Original PC# CV020817 CLOSED H HUGE Tl W/0 PERMITS CV040401 CLOSED H EXP BLDG PERMII CB023423 STARTED WITHOUT PERMITS PRIOR C E CASE PCR03128 ABANDOND SEASILVER SILVER USA MODIFY RM REVISE LITES & MEANS OF EGRESS Inspection History Comments SEE NOTICE ON CORRECTIONS ON WALLS BRACING @ CORRIDOR OK @ CORRIDOR WALLS & LOWER CEILING FRMG @ CORRIDOR GROUND BOXES BTM OF CORR CLNG SEE JOB PLANS Date 01/10/2008 12/27/2007 12/27/2007 12/11/2007 12/05/2007 12/05/2007 11/30/2007 11/28/2007 11/21/2007 11/08/2007 11/08/2007 Description 89 14 17 17 14 34 17 14 17 14 34 Final Combo Frame/Steel/Bolting/Welding, Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Interior Lath/Drywall Frame/Steel/Bolting/Welding Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Act CO AP AP PA AP CO AP PA NR NR NR Insp RB RB RB RB RB RB TP RB PC RB RB EsGii Corporation In Partnership with government for (BuiCding Safety DATE October 16, 2007 a APPLICANT a JURIS JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 07-2325 SET III PROJECT ADDRESS 1950 Cammo Vida Robles PROJECT NAME Corridor TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff ^J The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck | | The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to IXI Esgil Corporation staff did not advise the applicant that the plan check has been completed^ Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person XI REMARKS Perforated plans are being carried by applicant By Bryan Zuppiger Enclosures Esgil CorporationGA n MB n EJ n PC 10/09/2007 trnsmtl dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 , N • EsGil Corporation In Partnership with government for (BuiCding Safety DATE 10/4/07 Q AEEL1GANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 07-2325 SET II PROJECT ADDRESS 1950 Cammo Vida Robles PROJECT NAME Corridor TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Kimberly Bowers 1510 Front Street, Suite 400 San Diego, CA92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Kimberly Bowers Telephone # 6197020380 Date contacted ,0(^0T(by A^v ) Fax# 6197020383 Mail -- Telephone Fax^ In Person REMARKS By Doug Moody Enclosures Esgil Corporationn GA n MB n EJ n PC 9/27/07 trnsmtl dot 9320 Chesapeake Dnve Suite 208 + San Diego California 92123 *• (858)560-1468 + Fax (858) 560-1576 City of Carlsbad O7-2325 10/4/07 RECHECK PLAN CORRECTION LIST JURISDICTION City of Carlsbad PROJECT ADDRESS 1950 Cammo Vida Robles PLAN CHECK NO 07-2325 SET II DATE PLAN RECEIVED BY ESGIL CORPORATION 9/27/07 REVIEWED BY Doug Moody DATE RECHECK COMPLETED 10/4/07 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments The following items listed need clarification, modification'or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law A Please make all corrections on the original tracings and submit new complete sets of prints to B To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans C The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items D Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located on the plans Have changes been made not resulting from this list? QYes QNo n S City of Carlsbad 07-2325 10/4/O7 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 8 Corridors shall have walls and ceilings of one-hour construction Please revise details 1 on sheet Tl 7 1 to show the roof assembly or ceiling assembly to comply with section 10043431 10 Provide a complete architectural section of the corridor, showing all fire-resistive materials and details of construction for all floor, walls, roof and all penetrations Section 1004 3 4 See comment above 11 Duct penetrations of fire-rated corridor construction shall have smoke and fire dampers per Sections 713 10 and 713 11 Please revise the mechanical plans to show the opening in the rated corridor to be protected by smoke fire damper and not just fire dampers 13 Smoke dampers shall be installed per UBC Section 713 10 at all ducted or unducted air openings at penetrations of a) Corridors or horizontal exit walls 19 Show exit signs on the electrical lighting plan(s) As per UBC Section 1003 2 8, provide two sources of power to exit signs and exit illumination Please revise the lighting fixture schedule to show the emergency egress illumination and exit lighting to be provided with back-up power 20 WIRING METHODS AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits I was unable to find the note on the plans To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you EsGii Corporation In Partnership with government for (BuiCding Safety DATE September 18, 2007 JURISDICTION Carlsbad PLAN CHECK NO 07-2325 SET I PROJECT ADDRESS 1950 Cammo Vida Robles PROJECT NAME Corridor TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XJ The applicant's copy of the check list has been sent to Kimberly Bowers 1510 Front Street, Suite 400 San Diego, CA92101 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Telephone # 6197020380 Fax# 6197020383 Mail Telephone ^/ Fax y/ln Person REMARKS By Bryan Zuppiger Enclosures Esgil Corporation D GA D MB Q EJ D PC 09/10/2007 trnsmtl dot 9320 Chesapeake Dnve, Suite 208 4 San Diego, California 92123 + (858)5601468 + Fax (858) 560-1576 Carlsbad 07-2325 September 18, 2O07 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 07-2325 OCCUPANCY B TYPE OF CONSTRUCTION VN SPRINKLERS'? yes DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEW COMPLETED September 18, 2007 JURISDICTION Carlsbad USE office building corridor ACTUAL AREA 5453 OCCUPANT LOAD 0 i DATE PLANS RECEIVED BY ESGIL CORPORATION 09/10/2007 PLAN REVIEWER Bryan Zuppiger FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2001 CBC that adopts the 1997 UBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e. plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot Carlsbad O7-2325 September 18, 20O7 Important Notice Regarding the 2007 CBC If you are an architect, engineer, designer or contractor that performs work within the State of California, please be advised that a new building code will take effect on January 1, 2008 The new building code is based on the 2006 International Building Code (IBC) and it is significantly different than the Uniform Building Code (UBC) All plan review applications submitted after December 31. 2007 will be required to comply with the new code The 2007 CBC is currently available for purchase directly from the International Code Council, at www iccsafe org • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Please coordinate the area of construction square footage between sheet T1 1 1, sheet T1 1 2 and the application 3 Provide a section view of all new interior partitions that are referenced on the floor plan Show a) Type, size and spacing of studs Indicate gauge for metal studs Specify manufacturer and approval number or indicate "to be ICBO approved" b) Method of attaching top and bottom plates to structure (NOTE Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load) c) Wall sheathing material and details of attachment (size and spacing of fasteners) d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing 4 Show on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-O and 16-B 5 Specify lever-type hardware for passage doors on floors accessible to the disabled Title 24 6 Show that exits are lighted with at least one foot candle at floor level UBC Section 1003 292 Carlsbad O7-2325 September 18, 2O07 7 Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees Maximum leaf width is 4 feet Sections 1003 3 1 3 and 1003 3 1 4 8 Corridors shall have walls and ceilings of one-hour construction 9 Corridors shall have interior door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per UBC Section 713' 2 Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top UBC Section 10043432 1 10 Provide a complete architectural section of the corridor, showing all fire-resistive materials and details of construction for all floor, walls, roof and all penetrations Section 1004 3 4 11 Duct penetrations of fire-rated corridor construction shall have smoke and fire dampers per Sections 713 10 and 713 11 12 Fire dampers shall be installed per UBC Section 713 11 at all ducted or unducted air openings at penetrations of a) Corridors or horizontal exit walls 13 Smoke dampers shall be installed per UBC Section 713 10 at all ducted or unducted air openings at penetrations of a) Corridors or horizontal exit walls 14 Provisions in Chapter 7 require special treatment of penetrations at fire-resistive assemblies Provide typical details on the plans showing how the fire-resistive integrity will be maintained at the following conditions (Include the manufacturers' names and ICBO numbers (or equal) for any sealant) THROUGH-PENETRATIONS (through the entire assembly) Fire-resistive walls shall have penetrations protected with through-penetration fire stops having an F-rating, T-rating or complying with UBC Standard 7-1, depending on their locations, sizes and combustibility Fire resistive floor/ceiling assemblies shall have penetrations protected with through-penetration fire stops having and F-rating, T-ratmg or complying with UBC Standard 7-1, depending on their sizes, combustibility and whether the penetrations are in walls above MEMBRANE-PENETRATIONS (through only one side of an assembly) Fire-resistive walls shall have penetrations protected with membrane-penetration fire stops having an F-rating or complying with UBC Standard 7-1, depending on their size and combustibility Limited steel electrical outlet boxes (not exceeding 16 sq in , nor more than 100 sq in for any 100 sq ft of wall) require no protection Fire-resistive floors or ceilings having penetrations shall comply with Section 710 NOTE The plans should indicate the various fire-stop ratings required for all penetrations 15 Submit plan showing location of all panels Carlsbad O7-2325 September 18, 2OO7 16 Submit panels schedules 17 Submit electrical load calculations 18 Indicate existing mam service size 19 Show exit signs on the electrical lighting plan(s) As per UBC Section 1003 2 8, provide two sources of power to exit signs and exit illumination 20 Provide plans, calculations and worksheets to show compliance with current energy standards 21 Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems Provide the completed ENV-, LTG-, and MECH- forms showing energy compliance 22 On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design 23 The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans 24 WIRING METHODS AC Cable is not allowed in A, B, E, H, and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits 25 The use of flexible metal conduit as a grounding means must comply with City Policy 84-36 26 No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official City Policy The person responsible for their preparation must sign all final sheets of plans (California Business and Professions Code) To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation Thank you 'Carlsbad 07-2325 September 18, 2007 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO O7-2325 PREPARED BY Bryan Zuppiger DATE September 18, 2007 BUILDING ADDRESS 1950 Cammo Vida Robles BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN BUILDING PORTION tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 5453 cb RIHn Pprmit Foe hu OrHmanro ' IT ' Valuation Multiplier 3437 By Ordinance Reg Mod VALUE ($) 187,420 187,420 $891 93 Plan Check Fee by Ordinance Type of Review I I Repetitive FeeRepeats Complete Review D Other r-, Hourly Structural Only Hour* Esgil Plan Review Fee Comments $579 75 $499 48 macvalue doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB &lO7233g DATE f//0A? ADDRESS. RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAJRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Coc*MI«tom»P«Tf7in5 EnginMrfng ^pprevMl a V sr£ £ * * *5 a 3 o o oc c c HDD DD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner APN Address Gma Ruiz Phone (760) 602-4675 Type of Project & Use "H Zoning f^M General Plan ¥\ CFD (in/out) #_Date of participation Net Project Density.DU/AC Facilities Management Zone Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit ) Legend £3 Item Complete Q Item Incomplete - Needs your action Environmental Review Required YES NO K TYPE DATE OF COMPLETION Compliance with conditions of approval' If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/RESO NO PROJECT NO YES NO y TYPE DATE OTHER RELATED CASES Compliance with conditions or approval? If not, state conditions which require action Conditions of Approval DD D D DD Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES_ CA Coastal Commission Authority? YES_ NO NO~Y If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (619) 767-2370 Determine status (Coastal Permit Required or Exempt) Habitat Management Plan ^ Data Entry Completed? YES NO r^ If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB# toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE') Inclusionary Housing Fee required YES NO A (Effective date of Inclusionary Housing Ordinance - May 21,1993) Data Entry Completed? YES NO / (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees Construct Housing Y/N Enter Fee, UPDATE') H \ADMIN\COUNTER\BldgPlnchKRevChklst Rev 3/06 Site Plan Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed (structures, streets, existing street improvements, right-of-way width, ,dimensional' setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines D D 1 Applicability YES NO_ D D 2 Project complies YES NO_ KJ/A D D D D Zoning fsJ/A 1 Setbacks Front Interior Side Street Side Rear Top of slope 2 Accessory structure Front Interior Side Street Side Rear Structure separation Required Required Required Required Required setbacks |O//* Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown D D 3 Lot Coverage \j//^ Required. 4 Height | 5 Parking Required. Spaces Required Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments ^j^! Y?WITH AN! KJP OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE *\ H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Carlsbad Fire Department BLDG DEPTCOPY Plan Review Requirements Category TI, INDUST Date of Report 09-10-2007 Name Address Reviewed by Permit # CB072325 Job Name CBAD CORP CENTER-5453 SF TI Job Address 1950 CAMINO VIDA ROBLE CBAD submitted for review is inco adequately conduct a review carefully all comments ards Please review ded", Conditions Cond CON0002276 [MET] APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 09/10/2007 By MS Action AP SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP* BPDATE / / Business Name /i /) Uriir /^mmon Business Contact /Ws Telephone # Project Address I960 City Stale Zip Code APN# Mailing Address /) 1 U>o4 State Zip Code Plan File* Project Contact 3- Telephone # X The following questions represent the facility's activities, NOT the specific project description PART I FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION OCCUPANCY CLASSIFICATION Indicate by checking the item whether your business will use process or store any of the following hazardous materials If any of the items are checked applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal 1 D Explosive or Blasting Agents 2 D Compressed Gases 3 D Flammable/Combustible Liquids 4 D Flammable Solids 5 D Organic Peroxides 6 D Oxidizers 7 D Pyrophoncs 8 D Unstable Reactives 9 D Water, Reactives 10 D Cryogenics 11 D Highly Toxic or Toxic Materials 12 D Radioactives 13 D Corrosives 14 D Other Health Hazards 15 Pytone of These PART II SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD) If the answer to any of the questions is yes applicant must contact the County of San Diego Hazardous Materials Division 1255 Imperial Avenue 3rd floor San Diego CA 92101 Call (619) 338 2222 prior to the issuance of a building permit FEES ARE REQUIRED YES NO 1 D 2 D 3 D Expected date of Occupancy D D D 's vour DUSiness listed on the reverse side of this form'' S/ViH your business dispose of Hazardous Substances or Medical Waste in any amount? Gr Will your business store or handle Hazardous Substances in quantities equal to or greater than ^^55 gallons 500 pounds 200 cubic feet or carcinogens/reproductive toxins in any quantity? Q^Will your business use an existing or install an underground storage tank? Da Will your business store or handle Regulated Substances (CalARP)? GK' Will your business use or install a Hazardous Waste Tank System (Title 22 Article 1 0)? D CalARP Exempt Date Initials D CalARP Required Date Initials D CalARP Complete Date Initials PART III San Diego County Air Pollution Control District If the answer is yes to any of the following questions applicant must contact the Air Pollution Control District 91 50 Chesapeake Drive San Diego CA 92123 Call (858) 650 4550 prior to the issuance of a building permit YES D D D D NO/ OH Will the subject facility install or use any of the equipment listed on the Listing of Air Pollution Control District Permit Categones on the reverse side of this form? D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1 000 feet of the outer boundary of a school (K through 12) as listed in the current Directory of School and Community College Districts published by the San Diego County of Education and the current ^^Cahfomia Pnvate School Directory complied in accordance with the provisions of Education Code Section 33190? B^Does the building or structure for which this permit is requested contain any friable asbestos? ^ls there demolition involving the removal of a load supporting structural member? _ Briefly describe business activities Briefly descnbe proposed project I declare under penalty of perjury that to the best of my knowledge and bj Name of owner or Authonzed Agent rn are true and correct Signature of^Pwner or Authorized Agent Date - FOR OFFICAL USE ONLYFIRE DEPARTMENT OCCUPANCY CLASSIFICATION. BY DATE EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY HMMD APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY HMMD APCD RELEASED FOR OCCUPANCY COUNTY HMMD APCD DEHHM-9171 (08/02)County of San Dieeo - DEH - Hazardous Materials Division Check A License Contractor's License Detail Page 1 of2 Skip to CSLB Home | Content | Footer | Accessibility | Search CSLB CONTRACTORS | STATE LICENSE BOARD IIIII iiinoi; -S i „-• CONSUMERS 111 H' & rf % IH JOURNEYMEN;' im 'i'ti ,,,BUILDING OFFICIALS 07 GENERAL INFO About CSLB CSLB Newsroom Board and Committee Meetings Disaster Information Center CSLB Library Frequently Asked Questions Online Services » Check A License or HIS Registration e Filing a Construction Complaint e Processing Times e Check Application Status • Search for a Surety Bond Insurance Company e Search for a Workers Compensation Company How to Participate £la DISCLAIMER A license status check provides information taken from the CSLB license database Before relying on this information, you should be aware of the following limitations • CSLB complaint disclosure is restricted by law (B&P 71246) If this entity is subject to public complaint disclosure a link for complaint disclosure will appear below Click on the link or button t< obtain complaint and/or legal action information • Per B&P 7071 17 only construction related civil judgments reported to the CSLB are disclosed • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration • Due to workload there may be relevant information that has not yet been entered onto the Board < license database License Number Business Information Entity Issue Date Expire Date License Status Classifications Bonding Workers' Compensation 605294 _ _ _ _ Extract Date 10/16/2007 PREVOST CONSTRUCTION INC 400 S SIERRA AVENUE SOLANA BEACH CA 92075 Business Phone Number (858) 720 8559 Corporation 10/24/1990 JO/31/2008 _ __ This license is current and active All information below should be reviewed CLASS « I DESCRIPTION GENERAL BUILDING CONTRACTOR CONTRACTOR'S iOND This license filed Contractor's Bond number SU5019798 in the amount of $12 500 with the bonding company ARCH INSURANCE COMPANY Effective Date 01/01/2007 Contractor JL Bonding History. :iOND OF QUALIFYING INDIVIDUAL* The Responsible Managing Officer (RMO) JOHN RICHARD PREVOST JR certified that he/she owns 10 percent or more of the voting stock/equity of the corporation A bond of qualifying individual is not required Effective Date 01/18/1995 This license has workers compensation insurance with the STATE COMPENSATION INSURANCE FUND http //www2 cslb ca gov/General-Information/mteractive-tools/check-a-hcense/License+Detail asp 10/16/2007 Check A License Contractor's License Detail Page 2 of2 Policy Number 1215362 Effective Date 10/28/1991 Expire Date 11/01/2007 Personnel listed on this license (current or disassociated) are listed on other licenses Copyright © 2007 State of California http //www2 cslb ca gov/General-Information/mteractive-tools/check-a-hcense/License+Detail asp 10/16/2007 I c» Hc/» CA