Loading...
HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; ; CB972975; PermitSuite: BUILDING PERMIT 11/21/97 10:02 ^rAddress/^SO CAMINO VIDA ROBLE Permit Type: MISCELLANEOUS Parcel No: valuation: ° *Occupancy Group: Referenced™. Appl/Ownr : Fees pPe™it No: CB972975 Development No: 30-00 Construction Type: VN Status: ISSUED Applied: 10/09/97 SAN DIEGO, CA. **i23 619 565-8485 Coiiected & Credits Adjustments: Total Fees: Fee description . Miscellaneous Fee #1 * MISCELLANEOUS TOTAL ; ' ^' Balan Units Fee/0nit _____ __ s_^_:»-i«.-% ^ • . *- _, ' ' " " ' . 00 r\ r»00 30.00 Ext fee Data 30.00 PERMIT 30.00 j CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPLICATIONCITY OF CARLSBAD BUILDING DEPARTMENT2075 Las Palmas Dr., Carlsbad CA 92009(760)438-1161 FOR OFFICE USEPLAN CHECK NOEST. VALPlan Ck. DepositValidated ByDateusiness Name (at this address)Address (include Bldg/Suite #)Legal Description Unit No.Phase No.Total # of unitsProposed Use (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basts for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). Address License Class Name State License # City State/Zip City Business License # Telephone # Designer Name State License t Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS IS100] OR LESS) n CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure worker*' compensation coverage la unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sals (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of workt: ._ . „ PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 faet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code). LENDER'S NAME I certify that I have read the application ant City ordinances and State laws relating] to building property for inspection purposes. I AL! JUDGMENTS, COSTS AND EXPENSES WH id state that the above information is correct and that the information on the plans is accurate. 1 agree to comply with all construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned O AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, CH MAY IN ANY WAY ACCRUEVVGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations EXPIRATION: Every permit issued by the work authorized by such permit is not com or abandoned at any time after the work Is APPLICANT'S SIGNATURE LENDER'S ADDRESS over 5'0" deep and demolition or construction of structures over 3 stories in height. uilding Official under the provisions of this Code shall expire by limitation and become null and void if the building or enced within 365 days from th/date of such permit or if the building or work authorized by such permit is suspended commenced for a period of Igr/aays (Section 106.4.4 Uniform Building Code). DATE WHITE: File YELLOW: Applicant PINK: Finance REQUEST FOR BUILDING PERMIT FOR PARTIAL BUILDING CONSTRUCTION To: Building Official, jurisdiotipn of: Pursuant to the provisions of the Uniform Building Code, Section 303 (a), the undersigned requests that a building permit be issued for: for the proposed building to be located at: \*\ 5>o £l/uA\mo V\OA. and identified as Plan Review Number: Acknowledgment is made that plans for the entire structure are not complete and/or that the plan review has not been completed. We recognize that proceeding with partial construction at this time is entirely at our own risk, with no assurance that the permit for the entire building or structure will be granted. We further absolve the jurisdiction of: and Esgil Corporation, and officers and employees thereof, of all responsibility for the issuance of a partial permit and further agree that any work performed under this permit will be removed or otherwise corrected to be in accord with the requirements of the final approved plans when a permit for the entire building or structure is granted. It is agreed that neither the jurisdiction of: nor Esgil Corporation, and officers and employees thereof, will be liable for expenses incurred as a result of removal or correction of work which may be necessary to comply with the final approved plans. Signature: Date: <3& f:\pending\parpermtdoc 7/12/95 CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB972975 FOR 12/18/97 DESCRIPTION: UNDERGRD PLUM&ELEC CONDUIT,SEE TRANSMITTAL FOR OTHER ITEMS-TI-CB973316 TYPE: MISC JOB ADDRESS: APPLICANT: CONTRACTOR: OWNER: 1950 ALISI, BOB CAMINO VIDA ROBLE STE INSPECTOR AREA TP PLANCK* CB972975 OCC GRP CONSTR. TYPE VN LOT: PHONE: PHONE: PHONE: 619 565-8485 REMARKS: C/ SPECIAL INSTRUCT: PLUMBING WRAPPING INSPECTOR TOTAL TIME: —RELATED PERMITS-- CD 21 PERMIT* TYPE AS960024 ASC RW960018 ROW US960010 TU LVL DESCRIPTION PL Underground/Under Floor STATUS ISSUED ISSUED ISSUED ACT COMMENTS ***** INSPECTION HISTORY ***** DATE DESCRIPTION 121697 Ftg/Foundation/Piers 121597 Ftg/Foundation/Piers 121297 Ftg/Foundation/Piers 121197 Ftg/Foundation/Piers 121097 Ftg/Foundation/Piers 120897 Underground/Under Floor 120597 Underground/Under Floor 120497 Underground/Under Floor 120497 Underground/Conduit-Wiring 120397 Underground/Under Floor 120397 Underground/Conduit-Wiring 120297 Underground/Conduit-Wiring ACT PA PI PA PA NR AP NR NR AP AP AP NR INSP TP TP TP TP TP TP TP TP TP TP TP TP COMMENTS PLUMB TRNCH (1) SLAB PREP NOT COMP SLAB PREP @ CUTS SLAB PREP @ CUTS NOT COMP NOT COMP/WATER TEST SECT 7.5 TO 10 PART NOT COMP 17150ViaDelCampo Suite 307 San Diego, CA92127 1-800-487-0355 WYMAN TESTING LABORATORIES REPORT OF COMPRESSION TEST PROJECT P S B LENDING PROJECT NO.97-312 PROJECT ADDRESS CONTRACTOR 1950 CAMIKO VIDA ROBLE. CARLSBAD, CALIFORNIA RENQCQNTRACTING ARCHITECT/ENGINEER MILO ARCHITECTURE GROUP/R2H ENGINEERING BLDG. PERMIT NO. 97-2975 „___ PLAN FILE NO. SAMPLE DATA REPORT OF: |"x"| CONCRETE PLACEMENT DATE SUPPLIER MIX NUMBER . MORTAR [""] GROUT 12-17-97 PALOMAR 404003 PRISMS TYPE OF CEMENT ADMIXTURE II N/A DATE RECEIVED IN LAB MIX DESIGN PSI MIX DESCRIPTION TICKET NUMBER SLUMP GROUT ||OTHER 12-18-97 N/A N/A 794455 4 1/2" TIME IN MIXER CONG. TEMP N/A N/A PERCENT AIR AIR TEMP. N/A N/A UNIT WEIGHT WET N/A UNIT WEIGHT DRY N/A MIX REQUIRED PSI (f'c) 400Q PSI @ 28 DAYS SAMPLES MADE BY LOCATION OF PLACEMENT UTILITY POUR SW SIDE OF BLDG M. MILLER LABORATORY DATA COMPRESS IVE FIELD LAB DATE DIMENSIONS TEST AREA MAX LOAD STRENGTH IDENTITY NO. TESTED INCHES SQ. INCHES POUNDS PSI 7 28 28 H 17 18 19 20 12-24-97 01-14-98 01-14-98 6 X 12 6 X 12 6 X 12 28.27 28.27 28.27 79,000 124,000 121,000 2790 4390 4280 ALL SAMPLING AND TESTING PERFORMED IN GENERAL ACCORDANCE UITH ASTM TEST METHODS *ACTUAL MEASURED AREA C31, C39, C78, C138, C143, C172, C173, C231, C617, C10M LABORATORY DATA REMARKS DISTRIBUTION: OWNER. ARCHITECT. ENGINEER. CONTRACTOR. CITY. SUPPLIER CHECKED BY: fWfibt&f.Vtu REVIEWED BY DATE: /-/&-Y&' 0 DATE: t-( WYMAN TESTING LABORATORIES 17150ViaDelCampo Suite 307 San Diego, CA 92127 1-800-487-0355 REPORT OF COMPRESSION TEST PROJECT P S B LENDING PROJECT NO.97-312 PROJECT ADDRESS CONTRACTOR . 1950 CAMINO VIDA ROBLE. CARLSBAD, CALIFORNIA RENO CONTRACTING ARCHITECT/ENGINEER MILO ARCHITECTURE GROUP/R2H ENGINEERING BLDG. PERMIT NO. 97-2975 PLAN FILE NO. _ SAMPLE DATA REPORT OF: fxlCONCRETE PLACEMENT DATE SUPPLIER MIX NUMBER MORTAR ||GROUT 12-16-97 PALOMAR 404003 PRISMS IITYPE OF CEMENT ADMIXTURE WRDA 64 DAREX II AEA DATE RECEIVED IN LAB MIX DESIGN PSI MIX DESCRIPTION TICKET NUMBER SLUMP GROUT ||OTHER 12-17-97 4000 6.7 SK 794272 5 1/2" TIME IN MIXER CONC. TEMP 40 MIN N/A PERCENT AIR AIR TEMP. N/A N/A UNIT WEIGHT WET N/A UNIT WEIGHT DRY N/A MIX REQUIRED PSI (f'c) 4000 PSI @ 28 DAYS SAMPLES MADE BY LOCATION OF PLACEMENT SOG AT LINE 9.5 @ C.2 @ SEWER TRENCH D. WYMAN LABORATORY DATA COMPRESS IV! FIELD LAB DATE DIMENSIONS TEST AREA MAX LOAD STRENGTH IDENTITY NO. TESTED INCHES SQ. INCHES POUNDS PSI 7 28 28 H 13 14 15 16 12-23-97 01-13-98 01-13-98 6 X 12 6 X 12 6 X 12 28.27 28.27 28.27 109,000 139,500 141,000 3860 4930 4990 ALL SAMPLING AND TESTING PERFORMED IN GENERAL ACCORDANCE WITH ASTM TEST METHODS C31, C39, C78, C138, C143, C172, C173, C231, C617, C10M LABORATORY DATA REMARKS 'ACTUAL MEASURED AREA DISTRIBUTION: OWNER. ARCHITECT. ENGINEER. CONTRACTOR. CITY. SUPPLIER CHECKED BY: £$7(io£&t**^ / REVIEWED BY: ^]fDATE: /-/&* 9^ 0 DATE: 17150ViaDeICampo Suite 307 San Diego, CA92127 1-800-487-0355 WYMAN TESTING LABORATORIES REPORT OF COMPRESSION TEST PROJECT P S B LENDING PROJECT NO.97-312 PROJECT ADDRESS CONTRACTOR 1950 CAMINO VIDA ROBLE. CARLSBAD, CALIFORNIA RENO CONTRACTING ARCHITECT/ENGINEER MILO ARCHITECTURE GROUP/R2H ENGINEERING BLDG. PERMIT NO. 97-2975 PLAN FILE NO. SAMPLE DATA REPORT OF: [x]CONCRETE PLACEMENT DATE SUPPLIER MORTAR I | GROUT 12-15-97 PALOMAR PRISMS MIX NUMBER 404003 TYPE OF CEMENT ADMIXTURE II N/A DATE RECEIVED IN LAB MIX DESIGN PSI MIX DESCRIPTION TICKET NUMBER SLUMP _____ GROUT |~| OTHER 12-17-97 4000 NA 793958 4" TIME IN MIXER CONG. TEMP N/A N/A PERCENT AIR AIR TEMP. N/A N/A UNIT WEIGHT WET N/A UNIT WEIGHT DRY N/A MIX REQUIRED PSI (f'c) 4000 PSI @ 28. DAYS SAMPLES MADE BY R. DALE LOCATION OF PLACEMENT SOG TI ELEC/PLUMBING CUT OUTS @ APPROX B.5/2.5 LABORATORY DATA COMPRESS IVE FIELD LAB DATE DIMENSIONS TEST AREA MAX LOAD STRENGTH IDENTITY NO. TESTED INCHES SQ. INCHES POUNDS PSI 7 28 28 H 9 10 11 12 12-22-97 01-12-98 01-12-98 6 X 12 6 X 12 6 X 12 28.27 28.27 28.27 93,000 128,500 129,000 3290 4540 4566 ALL SAMPLING AND TESTING PERFORMED IN GENERAL ACCORDANCE UITH ASTM TEST METHODS C31, C39, C78, C138, CU3, C172, C173, C231, C617, C1064 LABORATORY DATA REMARKS DISTRIBUTION: OWNER. ARCHITECT. ENGINEER. CONTRACTOR. CITY. SUPPLIER CHECKED BY: PJ}?fit>/$H*t"^' REVIEWED BY: DATE: /— /&"-<?£/ " DATE: /-/?* WYMAN TESTING LABORATORIES 17150ViaDelCampo Suite 307 San Diego, CA92127 1-800-487-0355 REPORT OF COMPRESSION TEST PROJECT P S B LENDING PROJECT NO.97-312 PROJECT ADDRESS CONTRACTOR 1950 CAMIN6 V1IPA RDlfcE. CARLSBAD. CALIFORNIA RENO CONTRACTING ^_^ ARCHITECT/ENGINEER BLDG. PERMIT NO. _ MILO ARCHITECTURE GROUP/R2H ENGINEERING 97-2975 PLAN FILE NO. SAMPLE DATA REPORT OF: fxl CONCRETE PLACEMENT DATE SUPPLIER MORTAR | | GROUT 12-12-97 PALOMAR MIX NUMBER 404003 IITYPE OF CEMENT . ADMIXTURE WRDA 64 DAREX II AEA TIME IN MIXER N/A CONG. TEMP N/A PRISMS DATE RECEIVED IN LAB MIX DESIGN PSI MIX DESCRIPTION TICKET NUMBER SLUMP GROUT I(OTHER 12-17-97 4000 6.7 SK N/A 4" PERCENT AIR AIR TEMP. N/A N/A UNIT WEIGHT WET N/A UNIT WEIGHT DRY N/A MIX REQUIRED PSI (f c) 4000 PSI @ 28 DAYS LOCATION OF PLACEMENT SOG AT LINE B.2 SAMPLES MADE BY _ 7.5 @ ELECT TRENCH SUPERINTENDENT LABORATORY DATA COMPRESS IVE FIELD LAB DATE DIMENSIONS TEST AREA MAX LOAD STRENGTH IDENTITY NO. TESTED INCHES SQ. INCHES POUNDS PSI 7 28 28 H 5 6 7 8 12-19-97 01-09-98 01-09-98 6 X 12 6 X 12 6 X 12 28.27 28.27 28.27 95,000 127,000 131,000 3360 4500 4636 ALL SAMPLING AND TESTING PERFORMED IN GENERAL ACCORDANCE WITH ASTM TEST METHODS C31, C39, C78, C138, CH3, C172, C173, C231, C617, C1064 LABORATORY DATA REMARKS ^ACTUAL MEASURED AREA DISTRIBUTION: OWNER. ARCHITECT. ENGINEER. CONTRACTOR. CITY. SUPPLIER CHECKED BY: £#~%Lf$«^u4 REVIEWED BY DATE: /-/I'tf I DATE: /-/( WYMAN TESTING LABORATORIES 17150ViaDelCampo Suite 307 San Diego, CA 92127 1-800-487-0355 REPORT OF COMPRESSION TEST PROJECT P S B LENDING PROJECT NO.97-312 PROJECT ADDRESS CONTRACTOR 1950 CAMINO VIDA ROBLE, CARLSBAD. CALIFORNIA RENO CONTRACTING ARCHITECT/ENGINEER BLDG. PERMIT NO. MILO ARCHITECTURE GROUP/R2H ENGINEERING 97-2975 PLAN FILE NO. SAMPLE DATA REPORT OF: fx] CONCRETE PLACEMENT DATE SUPPLIER MORTAR | | GROUT 12-11-97 PALOMAR MIX NUMBER 404003 TYPE OF CEMENT ADMIXTURE II N/A PRISMS QH/S GROUT Q OTHER DATE RECEIVED IN LAB N/A MIX DESIGN PSI N/A MIX DESCRIPTION N/A TICKET NUMBER 793334 SLUMP 4" TIME IN MIXER CONC. TEMP N/A N/A PERCENT AIR AIR TEMP. N/A N/A UNIT WEIGHT WET N/A UNIT WEIGHT DRY N/A MIX REQUIRED PSI tf cV 4000 PSI @ 28 DAYS SAMPLES MADE BY LOCATION OF PLACEMENT TI SOG CUT OUTS LINES 10 R. DALE LABORATORY DATA COMPRESS I VI FIELD LAB DATE DIMENSIONS TEST AREA MAX LOAD STRENGTH IDENTITY NO. TESTED INCHES SQ. INCHES POUNDS PSI 7 28 28 H 1 2 3 4 12-18-97 01-08-98 01-08-98 6 X 12 6 X 12 6 X 12 28.27 28.27 28.27 84,000 118,000 122,500 2970 4170 4330 ALL SAMPLING AND TESTING PERFORMED IN GENERAL ACCORDANCE WITH ASTM TEST METHODS C31, C39f C78f C138, C143, C172, C173, C231, C617, C1064 LABORATORY DATA REMARKS "ACTUAL MEASURED AREA DISTRIBUTION: OWNER. ARCHITECT. ENGINEER. CONTRACTOR. CITY. SUPPLIER CHECKED BY: £#%k4&*zu REVIEWED BY: DATE:/-/Z-rr DATE: Wyman Testing Laboratories (619) 675-0270 JOB ADDRESS 1950 f!amino Vida Roble OWNER OR PROJECT NAME P S B Lending CONSTR. MAT! (TYPE, GRADE, ETC.) Concrete DESIGN STRENGTH SOURCE OR MFGR. 4000 Palomar Trans i DESCRIBE MAT'L (MIX DESIGN, RE-BAR GRADE & MFGR.) mix # 404003 FOR WEEK 97-312 ENDING Dec 19 1997 BLDG. PERMIT NO. PLAN FILE NO. B97-2975 ARCHITECT Milo Architecture Group ENGINEER t R2H Engineering GENERAL CONTRACTOR Reno Contracting CONTR. DOING REPORTED WORK Delaney LAB Wyman Testing Laboratories COVERING WORK PERFORMED WHICH REQUIRED APPROVAL BY THE SPECIAL INSPECTOR OF D REINFORCED CONCRETE D PRE-STRESSED CONCRETE D REINFORCED MASONRY D FIELD WELDING D H. S. BOLTING D SHOP WELDING D FIREPROOFING DNDT D D/B ANCHORAGE D SHOTCRETE D OTHER CONCRETE INSPECTION 12-15-97 Sampled & tested load #2 Palomar Transit Mix # 404003, ticket # 793958, truck # 715, slump ~4 "7' concrete ~temp 57 degrees. Placed at north end of large SOG cut out @ approximately B.5 line and 2.5 line. Cast 1 set of 4 concrete compressive strength cylinders marked 97-312-12/15 TI#3. NOW COMPLIANCE Contractor was directed to clean latience from saw cuts prior to concrete placement. Time in: Time out: 8:00 am 9:00 am Interim typed report for reference - original handwritten daily on file. Signed copy to be forwarded at a later date. PJD 12-29-97 Signed copy on file Rockland CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK. UNLESS OTHERWISE NOTED I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS & SPECIFICATIONS, AND APPLICABLE SECTIONS. Wyman Testing Laboratories (619) 675-0270 JOB ADDRESS IQSn Pflminn Vida Rohle> OWNER OR PROJECT NAME P S R T. ending CONSTR. MAT! (TYPE, GRAC*E, ETC.) <7onr'T"fa'i~<a DESIGN STRENGTH SOURCE OR MFGR. 4Qfin Palnmar Transi DESCRIBE MAT'L {MIX DESIGN, RE-BAR GRADE & MFGR.) miv rtocirrn Jl And-fin^ FOR WEEK 97-312 END|NG Dec 19 1<? 97 BLDG. PERMIT NO. PLAN FILE NO. B97-2975 ARCHITECT Milo Architecture Group ENGINEER t R2H Engi ne»eri no GENERAL CONTRACTOR Rpno Contracting CONTR. DOING REPORTED WORK " LAB Wvman Testina Laboratories COVERING WORK PERFORMED WHICH REQUIRED APPROVAL BY THE SPECIAL INSPECTOR OF D REINFORCED CONCRETE D PRE-STRESSED CONCRETE D REINFORCED MASONRY D FIELD WELDING D H. S, BOLTING D SHOP WELDING D FIREPROOFING D NDT n D/B ANCHORAGE D SHOTCRETE D OTHER CONCRETE INSPECTION 12-16-97 Cast one set of four test cylinders from this S.O.G. @ the sewer line trench -@- lirre-9;5"@~cr;2T-Th-e"slump was 5 1/2", the concrete was suppllHd"byTalomar Transit Mix , ticket # 794272, truck #717. Time in: 9:00 am Time out: 11:00 am Interim typed report for reference - original handwritten daily on file. Signed copy to be forwarded at a later date. PJD 12-29-97 Signed copy on file Daniel Wyman CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK. UNLESS OTHERWISE NOTED I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS & SPECIFICATIONS, AND APPLICABLE SECTIONS. SlGNAIUUt Of- RtGlSlfcNtD INSPECTOR DATE OF REPORT REGISTER NUMBER Wyman Testing Laboratories (619)675-0270 COVERING WORK PERFORMED WHICH D REINFORCED CONCRETE REQUIRED APPROVAL BY THE SPECIAL D PRE-STRESSED CONCRETE INSPECTOR OF D REINFORCED MASONRY D FIELD WELDING D H, S. BOLTING D SHOP WELDING D FIREPROOFING D SHOTCRETE n NDT D OTHER D D/B ANCHORAGE Vida Roble, Carlsbad FOR WEEK _„„ .. « „ „ ENDING DEC. 19 #7 SBPfiilBSfffif AME .NO.PLAN FILE NO. >NSTR. MAT'L <TYPE. GRADE, ETC.) STRENGTH Engineering DESCRIBE MAT'L (MIX DESIGN. RE-BAR GRADE & MFGR.) CONTR. DOING REPORTED WORK an Testing Laboratories CONCRETE INSPECTION 12-17-97 rested placement of concrete for utility trenches inside building, slump =4- 1/2". One set of 4 cylinders made. CLS 12-31-97 Signed copy on file Matt Miller CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK. UNLESS OTHERWISE NOTED I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS & SPECIFICATIONS, AND APPLICABLE SECTIONS.~DATE OF REPORT REGISTER NUMBE!*" Wyman Testing Laboratories (619)675-0270 COVERING WORK PERFORMED WHICH REQUIRED APPROVAL BY THE SPECIAL INSPECTOR OF REINFORCED CONCRETE PRE-STRESSED CONCRETE REINFORCED MASONRY D FIELD WELDING D H. S. BOLTING n SHOP WELDING D RREPROOFING DNDT D D/B ANCHORAGE D SHOTCRETE D OTHER Vida Roble, Carlsbad FOR WEEK „„,. , „ n „ ENDING DEC. 19 l97 AME -NO.PLAN FILE NO. JNSTR. MAT'L (TYPE, GRADE. ETC.) STRENGTH DESCRIBE MAT'L (MIX DESIGN. RE-BAR GRADE & MFGR.) 404003 CONTR. DOING REPORTED WORK an Testing Laboratories CONCRETE INSPECTION 12-18-97 Tested and placement of concrete for utility pour at nw side of building (inside), Slump=4-l/2"/ One set of 4 cylinders made. CLS 12-31-97 Signed copy on file Matt Miller CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK. UNLESS OTHERWISE NOTED I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS & SPECIFICATIONS, AND APPLICABLE SECTIONS. SlGNAIUlib OF REGISTERED INiiPbOIUIJ DATE OF REPORT "REGISTER NUMBER Wyman Testing Laboratories (619) 675-0270 ^S^eiunino Vida Roble, Carlsbad W*t R fiSfflMfl^^epair eSttc'reW^' GRADE- ^ SWflprwENGTH SOUI£afbffiIr TX DESCRIBE MAT'L (MIX DESIGN, RE-BAR GRADE & MFGR.) Palomar transit Mix #404003 NC97-312 ^NlEK DEC. 12 ^Q1 ^tiSaB^flHIP- PLAN FILE NO. ARCHITECT ENGINEER ^M6LCt?8BtSacting GC^WyX^S REPORTED WORK ^man Testing Laboratories COVERING WORK PERFORMED WHICH D REINFORCED CONCRETE REQUIRED APPROVAL BY THE SPECIAL D PRE-STRESSED CONCRETE INSPECTOR OF D REINFORCED MASONRY D FIELD WELDING D H. S. BOLTING a SHOP WELDING D FIREPROOFING D NDT D D/B ANCHORAGE D SHOTCRETE D OTHER CONCRETE INSPECTION 12-11-97 Reinforced concrete at tenant improvement electrical/plumbing slab on grade cut outs using Palomar Transit Mix #404003 and reinforcing #4 dowels embedded @ approx. 36" o.c. W/#3 cross bars @ 12" o.c. Progress this date: From 10 line to 1 line and from A line to C line. Cast one set of 4 concrete compressive strength specimens from load #2 marked 97-312-TI-l. NON-Compliance: Directed concrete contractor to clean latience from saw cuts. CLS 12-18-97 Signed copy on file. Rockland Da XO -r-! / CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK. UNLESS OTHERWISE NOTED I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS & SPECIFICATIONS, AND APPLICABLE SECTIONS. /TO•*—siSNAiur: EsGil Corporation Professional &tan fyvitw 'Engineers DATE: 11/20/97 a APPLICANT JURISDICTION: Carlsbad /a PLAN REVIEWER a FILE PLAN CHECK NO.: 97-2975 SET: II PROJECT ADDRESS: 195O Camino Vida Roble PROJECT NAME: PDS Lending Corp. Tl/Underground Elec. & Plumb. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. Please see Remarks below. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bob Lisi Telephone #; In person recheck Date contacted: (by: ) W Fax #: Mail Telephone Fax In Person // ) REMARKS: Mr. Bob Lisi will carry the 2 perfowite^ Set II plans to the City of Carlsbad. This per telephone conversation with John. Please before issuing the permit for partial construction limited to underground plumbing drain and Waste piping and underground electrical conduits that the Request for Building Permit for Partial Building Construction document rolled up with the plans be signed and dated by the gWner, architect/engineer, and contractor and save with permit documents. By: Mike Puckett Enclosures: Esgil Corporation D GA D CM D EJ D PC log trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4- (619)560-1468 + Fax (619) 560-1576 EsGll Corporation tProfessionafPfon Sfevievf Engineers DATE: 10/20/97 JURISDICTION: Carlsbad a FILE PLAN CHECK NO.: 97-2975 SET: I PROJECT ADDRESS: 1950 Camino Vida Roble PROJECT NAME: PDS Lending Corp. TI/Underground Elec. & Plumb. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Milo Architecture Group 3914 Murphy Canyon, San Diego, Ca. 92123 Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Mike Puckett Enclosures: Esgil Corporation D GA D CM D EJ D PC 10/13/97 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (619)560-1468 4 Fax (619) 560-1576 Carlsbad 97-2975 10/20/97 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 97-2975 JURISDICTION: Carlsbad OCCUPANCY: B USE: Office TYPE OF CONSTRUCTION: ACTUAL AREA: ALLOWABLE FLOOR AREA: STORIES: HEIGHT: SPRINKLERS?: OCCUPANT LOAD: REMARKS: The above information was not available at this plan submittal. DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: ESGIL CORPORATION: 10/13/97 DATE INITIAL PLAN REVIEW PLAN REVIEWER: Mike Puckett COMPLETED: 1O/20/97 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1994 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1994UBC) tifoiw.dot Carlsbad 97-2975 10/20/97 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560- 1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Indicate on the Title Sheet of the plans, the name of person responsible for the preparation of the plans. Section 106.3.3. 3. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 4. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1994 UBC, UMC and UPC and 1993 NEC. 5. On the first sheet of the plans indicate: • The floor area of the remodeled area, • Type of construction of the existing building, • Present and proposed occupancy classifications of the remodel area, • The floor where the tenant improvement is located, • The occupant load of the remodel area(s). 6. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 106.3.3. Carlsbad 97-2975 10/20/97 7. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor-ceiling assemblies or roof-ceiling assemblies. 8. Provide complete plumbing plans, including: • Complete drain, waste and vent plans. • Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1217.0 • Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 • Show water heater size, type and location on plans. UPC, Section 501.0 9. Show 1/4 inch per 12 inch slope on drain and waste lines. UPC Section 708.0 10. New water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2, H & S Code, Section 17921.3(b). 11. New urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code, Section 17921.3(b). 12. Provide calculations based on Appendix Chapter 29 UBC for number of plumbing fixtures per sex based on occupant load. Show on plans layout of of required plumbing fixtures. 13. Submit complete service and feeder one line diagram. NEC 215-5. 14. Show fuse/circuit breaker sizes on the single line diagram. NEC 240-6. 15. Show on the single line diagram the conduit and wire sizes. 16. Specify the wiring method you intend to use for this project (i.e., EMT, Metal Flex, NMC etc.). Carlsbad 97-2975 1O/20/97 17. Show the location of all panels, load centers, switchboards, and transformers. NEC 110-16,240-24,300-21. 18. Submit complete panel schedule(s). To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Mike Puckett at Esgil Corporation. Thank you. Carlsbad 97-2975 10/2O/97 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Mike Puckett BUILDING ADDRESS: 1950 Camino Vida Roble BUILDING OCCUPANCY: B PLAN CHECK NO.: 97-2975 DATE: 10/20/97 TYPE OF CONSTRUCTION: BUILDING PORTION j BUILDING AREA 1 (ft-2) Tenant Improvement Air Conditioning Fire Sprinklers Esgil Fee Not applicable VALUATION MULTIPLIER 2hrs. @87.15/hr. Esgil Fee ($) 174.30 174.30 D 199 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ D 199 UBC Plan Check Fee D Plan Check Fee by ordinance: $ Type of Review: D Complete Review D Structural Only £3 Hourly O Repetitive Fee Applicable [U Other: Esgil Plan Review Fee: $ 174.30 Comments: Sheet 1 of 1 macvalue.doc 5196 BUILDING PERMIT PCR No: PCR97099 12/05/97 08:47 Project No: A9703795 Page 1 of 1 Development No: Job Address: 1950 CAMINO VIDA ROBLE Suite: 2026 12/05/77 0001 01 07 Permit Type: PLAN CHECK REVISION C-PRMT 55.00 Parcel No: Lot#: Valuation: 0 Construction Type: NEW Occupancy Group: Reference*: Status: ISSUED Description: REVISED FIXTURE LOCATION IN Applied: 12/03/97 : TOILETS ON WEST SIDE Apr/Issue: 12/05/97 Entered By: JM Appl/Ownr : ALISI, BOB 619 565-8485 3914 MURPHEY CANYON ROAD SAN DIEGO, CA. 92123 *** Fees Required *** Collected & Credits *** Fees: Adjustments: Total Fees: Fee description Plan Check Revisi 55 .00 . 00 55.00 Ext fee Data 55.00 CLEARANCE CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPLICATIONCITY OF CARLSBAD BUILDING DEPARTMENT2075 Las Palmas Dr., Carlsbad CA 92009(760)438-11611. PROJECT-INFORMATION FOR OFFICE USE OI\LLYPLAN CHECK NO.EST. VAL.Plan Ck. DepositValidated ByDateAddress (include Bldg/Suite »|Business Name (it this address)Description of Work2. .CONTACT PERSON W different from appBcent) Name Address ' Crty 3. APPLICANT O Contractor Q Agent for Contractor Q Owner D Agent for Owner State/Zip Telephone *^F8*L*7 Name 4. PROPERTY OWNERu Address City State/Zip Telephone *" Address City State/Zip Telephone *Name 5. CONTRACTOR - COMPANY NAME [Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any.structure, prior to Its issuance, also requires the applicant for such permit to fHe a signed statement that he is licensed pursuant to the provisions of the Contractor's License Lew (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a dvll penally of not more then five hundred dollars 1*5001). Name State License 9 Address License Class City State/Zip City Business License f Telephone * Address City State/Zip TelephoneDesigner Name State License # 6. WORKERS'COMPENSATION - -, -- - _.— ... _ ---.-*-»• -— ;- -.,.-,.-,, Workers' Compensation Dederation: I hereby affirm under penalty of perjury one of the following declarations: Q I have end will maintain a certificate of consent to self-insure for workers' compensation ss provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit Is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Dete (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100) OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shell not emptoy any person in any manner so as to become subject to the Workers' Compensation Lews of California. WARNING: Failure to secure workers' compensation coverage is unlawful, end aha! subject an employer to criminal penahlea and tivfl fines up to one hundred thousand dollars 1*100,000), hi addition to the cost of compensation, damages es provided for In Section 3706 of the Labor code. Interest end attorney's fees. . SIGNATURE DATE 7. OWNER-BUILDER DECLARATION " • ;.-.•• -•— - -...., -..n:;~v-fr=, ,..-. •• . ., *TKW - .. * I hereby affirm that I am exempt from the Contractor's License Lew for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure ra not intended or offered for sole (Sec. 7044, Business end Professions Code: The Contractor's License Lew does not apply to an owner of property who buHds or Improves thereon, and who does such work himself or through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the building or Improvement Is sold within one yeer of completion, the owner-builder wHI have the burden of proving that ha did not buttd or Improve for the purpose of sale}. Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the prefect (Sec. 7044, Business end Professions Code: The Contractor's License Lew does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractorta) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Cods for this reason: 1 I personally plan to provide the major labor and matariels for construction of the proposed property Improvement. D YES O^O 2. 1 (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (Include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I nave hired the following person to coordinate, supervise end provide the major work (Include name / address / phone number / contractors license number): 5. I will provide some of the work, but I heve contracted (hired) the following persons to provide the work Indicated (indude name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE 'COMPLETE THIS SECTION TOR WQrWteSJDWrttt tmb«^ -."^r-.:-- :- Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management end prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES D NO Is the applicant or future building occupant required to obtain * permit from the air pollution control district or air quality management district? Q YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. «. CONSTRUCTION LENDING AGENCY ' ' "™""""' """. ?.- —: yr-.r-'"^-^'— ' -• ->—•=- • — I hereby affirm that there is a construction lending agency for the performance of the work for which this permit Is issued (Sec. 3097(i) Civil Codel. LENDERS NAME LENDER'S ADDRESS 9. APPLICANT CERTIFICATION I certify that I have read the application City ordinances and State laws relatiifg t .that the above information Is correct and that the information on the plans is accurate. I agree to comply with all buMdingSbntmiction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes, t AllSO AGREE TO "SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES W HIGH MAY IN ANY WAX. ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for e EXPIRATION: Every permit issued by th work authorized by such permit is not co _„ „„ or abandoned at any time after the work is) commenced for a period APPLICANT'S SIGNATURE '-•-, cevations over 5'0' deep and demolition or construction of structures over 3 stories in height. Building Official under the provisions of this Code shall expire by limitation and become null end void if the building or menced within 365 days from the date of such permit or If the building or work authorized by such permit is suspended 180 days (Section 106.4.4 Uniform Building Code). DATE WHITE: File YELLOW: Applicant PINK: Finance EsGil Corporation <EngineeTS DATE: 12/3/97 JURISDICTION: Carlsbad O~PLANREVIEWER a FILE PLAN CHECK NO.: 97-2975 (PCR 97-99) SET: I PROJECT ADDRESS: 1950 Camino Vida Roble PROJECT NAME: PSB Lending Underground Only Revision The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Robert Lisi Telephone #: In person plan check Date contacted: (by: ) Fax #: Mail Telephone Fax In Person XI REMARKS: Mr. Robert Lisi will carry the perforated Owner Set sheet P-4 to the City of Carlsbad. By: Mike Puckett Enclosures: Esgil Corporation 1. D GA D CM D EJ D PC log tm8mtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (619)560-1468 + Fax (619) 560-1576 Carlsbad 97-2975 (PCR 97-99) 12/3/97 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 97-2975 (PCR 97-99) PREPARED BY: Mike Puckett DATE: 12/3/97 BUILDING ADDRESS: 1950 Camino Vida Roble BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING PORTION Revision Air Conditioning Fire Sprinklers TOTAL VALUE BUILDING AREA (ft-2) VALUATION MULTIPLIER Hourly rate VALUE ($) G 199 UBC Building Permit Fee G Bldg. Permit Fee by ordinance: $ D 199 UBC Plan Check Fee G Plan Check Fee by ordinance: $ Type of Review: G Complete Review G Structural Only G Hourly G Repetitive Fee Applicable G Other: Esgil Plan Review Fee: $ 43.57 Comments: Esgil Fee = .5 x 87.15 = 43.57 Sheet 1 of 1 macvalue.doc 5196