HomeMy WebLinkAbout1950 CAMINO VIDA ROBLE; ; CBC2017-0648; Permit(City of
Carlsbad
Commercial Permit
Print Date: 12/03/2018 Permit No: CBC2017-0648
Job Address: 1950 Camino Vida Roble
Permit Type: BLDG-Commercial Work Class: Tenant Improvement Status: Closed - Finaled
Parcel No: 2120931200 Lot U: Applied: 12/13/2017
Valuation: $175,000.00 Reference U: Issued: 04/03/2018
Occupancy Group: Construction Type: Permit
Finaled:
U Dwelling Units: Bathrooms: Inspector: MColI
Bedrooms: Orig. Plan Check U: Final
Plan Check U: Inspection: 12/3/2018 2:40:49PM
Project Title:
Description: BUCHANAN: AWNINGS AND EXTERIOR SITE WORK
Applicant: Owner:
DRILLING AND FOUNDATIONS INC BSP CACC LLC
TIM SEAMAN
P0 Box 5955 1900 Main St C/O Allen Matkins Leck
CHULA VISTA, CA 91912-5955 IRVINE, CA 92614
619-993-8846
BUILDING PERMIT FEE ($2000+) $892.25
BUILDING PLAN CHECK FEE (BLDG) $624.58
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $89.00
5B1473 GREEN BUILDING STATE STANDARDS FEE $7.00
STRONG MOTION-COMMERCIAL $49.00
Total Fees: $1,661.83 Total Payments To Date: $1,661.83 Balance Due: $0.00
Please take NOTICE that approval of your project includes the "Imposition' of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov
LOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: EJPLANNING EJENGINEERING EJBUILDING []FIRE EJHEALTH EIHAZMATIAPCD
Building Permit Application Plan Check No. CJ17 11CL.
Est. Value /7 s ,cPO c) crCity of 1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558 CceirIsIacI Plan Ck. Deposit email: building@carlsbadca.gov
Date f (p www.carlsbadca.gov
JOBADDRESS q -0 V!.II,. ft SLJITE#/SPACE#/UNIT# APN
- - -
CT/PROJECT# LOT# PHASE# #OFUNITS IBE0M5 I# BATHROOMS ITENANT BUSINESS NAME IC0NSTR.TYPE OCC. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected
r ,'CUj Aro.v Mq uf\ ffrq ii
e - It (A$Cctpiitj Areq 5 Aroi &"frcice.
tjo I{er-or
EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) I FIREPLACE AIR CONDITIONING
YESD# NOE YES NO E]
IFIRESPRINKLERS
YESE NOfl
APPLICANT NAME Tt" Secvvcii PROPERTY OWNER NAME 4i4 qrhit5 Primary Contact
ADDRESS o y ADDRESS Ai4 20
CITY STATE CA ZIP q c1 CITY jpr- ck
STATE ZIP qztkD
PHONE FAX PHONE qq(l FAX
EMAIL
:o
EMAIL
DESIGN PROFESSIONAL .-'
,.-
CONTRACTOR BUS. NAME cr (Or
ADDRESS
'Y3(o ' 'ecco.. 4 ADDRESS Serreo V&
CITY
CA
ZIP STATE CITY STATE CA ZIP qZIZI
PHONE FAX PHONE FAX
EMAIL EMAIL
1 Lt)1!2OL1 STATE LIC. C STATE LIC.# I css I CITY BUS. LiC.
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the
Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: lherebyaffirm under penalty of perjury one of the following declarations:
LJ I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. 'S'fancfe Policy No. c1 _2_.. I_'7 Expiration Date 10 Il))
This section need not be completed if the permit is for one hundred dollars ($100) or less. II Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employerto criminal pefialties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, dama a as provided for in Section 3706 of the Labor code, interest and attorney's fees.
' CONTRACTOR SIGNATURE ENT DATE q (f (
..........................................
(hereby affirm that lam exempt from Contractor's License Law for the following reason:
EJ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
El I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
EJ I am exempt under Section ______________Business and Professions Code for this reason:
I personally plan to provide the major labor and materials for construction of the proposed property improvement. Dyes IINo
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name address I phone / contractors' license number):
I, plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone I type of work):
..PROPERTY OWNER SIGNATURE DAGENT DATE
Is the applicant or future building occupant required to submit a business acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the pla
Presley-Tanner Hazardous Substance Account Act? Yes No
Is the applicant or future building occupant required to obtain a Permit from the air pollution control district or air quality management district? Yes No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
Kj
- - -
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
-N - 0420010W -
I certify that I have read the application and state that the above information iscorrectand that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to buildingconslruction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 50' deep and demolition orconstniclion of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the previsions of this Code shall expire by limitation and become null and void if the building or work authotized by such permit is not commenced within
180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
..APPLICANT'S SIGNATURE /..cu..'1 21.2_L_.__ DATE P- i_:; 1;7
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
CERTIFI C A TEN .. P r ojects
Fax (760) 602-8560, Email bUiIdingt.carIsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
r0#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OP11ONS
PICK UP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On P. 1)
ASSOCIATED CB#
MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. NO CHANGE IN USE/ NO CONSTRUCTION
MAIL! FAX TO OTHER:
CHANGE OF USE! NO CONSTRUCTION
..APPLICANT'S SIGNATURE DATE
Permit Type: BLDG-Commercial Application Date: 12/13/2017 Owner: BSP CACC LLC
Work Class: Tenant Improvement Issue Date: 04/03/2018 Subdivision: CARLSBAD TCT#81-46 LJNIT#02
Status: Closed - Finaled Expiration Date: 12/10/2018 Address: 1950 Camino Vida Roble
Carlsbad, CA 92008-6599
IVR Number: 8318
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
04/26/2018 04/26/2018 BLDG-14 066187.2018 Partial Pass Michael Collins Reinspection Incomplete
Frame/Steel/Bolting!
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior entry so/fit only Yes
BLDG-34 Rough 056188.2018 Partial Pass Michael Collins Reinspection Incomplete
Electrical
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior entry soffit only Yes
06/16/2018 05/15/2018 BLDG-14 058044.2018 Failed Michael Collins Reinspection Complete
Frame/Steel/Bolting!
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No access to framing, 1St stop No
BLDG-Building Deficiency Exterior entry soffit only Yes
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No access to framing, 1st stop No
BLDG-Building Deficiency Second stop, exterior column frame. Yes
BLDG-Building Deficiency Exterior entry so/fit only Yes
BLDG-17 Interior 058045-2018 Failed Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code, exterior lath No
BLDG-18 Exterior 058211-2018 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Second stop. Yes
05/16/2018 05/16/2018 BLDG-17 Interior 058217.2018 Cancelled Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code, exterior lath No
06/12/2018 06/12/2018 BLDG-14 060671-2018 Passed Michael Collins Complete
Frame/Steel/Bolting!
Welding (Decks)
Checklist Item COMMENTS ,
Passed
BLDG-Building Deficiency Exterior column top Yes
12/03/2018 12/03/2018 BLDG-Final 077689.2018 Passed Michael Collins Complete
Inspection
December 03, 2018 Page 1 of 2
I EsGil
DATE: December 21, 2017
JURISDICTION: Carlsbad
PLAN CHECK #.: CBC2017-0648 SET: I
PROJECT ADDRESS: 1950 Camino Vida Roble
PROJECT NAME: Awning Addition
U APPLICANT
A1 JURIS.
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LI The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
LI The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LI The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
LI EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:
'
Telephone #:
Date contacted: (by-0) Email:
Mail Telephone Fax In Person
LI REMARKS:
By: Kurt Culver Enclosures:
EsGil
E GA E EJ D MB El PC 12/14/17
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad CBC2017-0648
December 21, 2017
[DO NOT PAY- THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK #.: CBC2017-0648
PREPARED BY: Kurt Culver DATE: December 21, 2017
BUILDING ADDRESS: 1950 Camino Vida Roble
BUILDING OCCUPANCY:
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Awning/Remodel 175,080
Air Conditioning
Fire Sprinklers
TOTAL VALUE 175,000
Jurisdiction Code 1cb IBY Ordinance
Bldg. Permit Fee by Ordinance V
Plan Check Fee by Ordinance V
Type of Review: 21 Complete Review
E Repetitive Fee E Other
Hourly Repeats
EsGil Fee
E Structural Only
I $892.311
I 7$-58-0,001
I $508.62
Comments:
Sheet 1 of 1
BNVE
STRUCTURAL .CIVIL .SURVEY .LAND PLANNING
9449 Balboa Avenue, Suite 270 aSan Diego, CA 92123
Phone (619) 299-5550 • Fax (619) 299-9934
www.bwesd.com
ENGINEER: Dane Hansen
DATE: December 6, 2017
PROJECT NUMBER: 13020A.1
STRUCTURAL CALCULATIONS
FOR
1950 Camino Vida Roble Awning
Carlsbad, CA
Table of Contents:
ProjectLoads ..................................... .................................................................................. 1
AwningDesign ..................................................................................................................10
AnchorageDesign .............................................................................................................24
1ESS/0
OF ct.
DATE SIGNED: 12/6/17
Prepared for - - _______ - -
CBC20I7-0648 idStudios 1950 Camino Vida Roble
AWNINGS AND EXTERIOR SITE WORK
236 S Sierra Avenue, Suite 110
Solana Beach, CA 92075 12/13/2017
CBC20I7-0648
SHEET
l { I H I JOB.NCL_
±4j
re i•ii..i.i..ii.ii
ilL hf t±
III
:t
+ 4
I -L-• -
J -L :T1 HI 4L --+4-
IC,
:J 4.
1_LIIft11 I-U. I j L I I ' J t INGMURED
-'---ENGR.-
1O 11 POJECTtLLI LL• :4 !4J
I ItTTt r - - - - I • I I - I I I - - iII
i1I
I 4 I19i ;
,11[1j}i .i,i
f 1 '4
jTi I I 1 J L1 E.4-...t p ,-cj
± : -ii2-fflhtt 1 Htfl
:J: jT Th ttfttVth.
EL!
l ye
4----f 4 LL
---------------
~ i rrT1 '1 ' r+ii7 i ri - f4 40DL/Jo7
____r
j I 1-tTl4 4 ft1 fr Th-
1 L Tr.I1F
IIIth I' LIJI ±ft U I1
41,
-1 ii -i - . I I : I . ;-[ j. 1.' . I! I-t.- i•T--•- : -
H ki1iL ~ '4 11J Th- IH 1 1 t
I IATU11 J
________
'
- NGR1 I I I j J J _____ L JO6 N(L
PROJECT 1f jr Tt t-It --i 1 1 rrr-r1rr1TTT-r-n-T1--1-T-- -f-i -' • - - tt _. .•_
tUij• ft " ttL:::U± 4" jj~coy, 4 ft - -4 tj TI -Hi d i t-f -L Trr -4 t • - - 1_ - r -- tft: tj1Ad 4J D
:4
i1t ii
00I1(D FL bUZ 6 t4'
lit
T.
_ I t-ft ftfi H I-i
4 :4 4:
Pct
•
J;
"! Ti 13
ItJ 1 1tH H'H Th11tJ41 Ift
r ii_Li tLt ., I
JJjJ. L.L
Ii
JT
. 1••
ftiHi1tHifH
•
ltji
C!
± ----+ -• * +-t-•t - - 4•
ti!
tJ I I - r1 I i I
iiiiuiui I Uesgn Maps Summary Report
jSUM Design Maps Summary Report
User-Specified Input
Building Code Reference Document ASCE 7-10 Standard
Q Site Coordinates
(which utilizes USGS hazard data available in 2008)
33.122160N, 117.2839°W
Site Soil Classification Site Class 0 - "Stiff Soil"
Risk Category I/Il/Il!
USGS-Provided Output
S= 1.079g SMS = 1.153g S= 0.769g
0 5, = 0.416 g SMI = 0.659 g So, = 0.440 g
For information on how the 55 and SI values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP building code reference document,
MCE, Response Spectrum Design Response Spectrum
Period, T (sec) Period. r (sec)
For PGAM, TO C, and Cei values, please view the detailed report,
ough this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the
racy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge.
3
111
1iI3UIU11 Liesign Maps L)etaliea Report
IJSGS Design Maps Detailed Report 4
ASCE 7-10 Standard (33.122160N, 117,2839°W)
Site Class D - "Stiff Soil, Risk Catgory I/Il/Ill
0- ,ection 11.4.1 - Mapped Acceleration Parameters
Note: Ground motion values provided below are for the direction of maximum horizontal
spectral response acceleration. They have been converted from corresponding geometric
mean ground motions computed by the USGS by applying factors of 1.1 (to obtain S) and
1.3 (to obtain Si). Maps in the 2010 ASCE-7 Standard are provided for Site Class B.
Adjustments for other Site Classes are made, as needed, in Section 11.4.3.
From Figure 22-1 111 S5 = 1.079 g
From Figure 22212) S1 = 0.416 g
Section 11.4.2 - Site Class
The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or
the default has classified the site as Site Class D, based on the site soil properties In
accordance with Chapter 20.
Table 20.3-1 Site Classification
Site Class or
2. Hard Rock
---
>5,000 ft/s N/A N/A
B. Rock 2,500 to 5,000 ft/s N/A N/A
Very dense soil and soft rock 1,200 to 2,500 ft/s >50 >2,000 psf
Stiff Soil 600 to 1,200 ft/s 15 to 50 1,000 to 2,000 psf
Soft clay soil <600 ft/s <15 <1,000 psf
Any profile with more than 10 ft of soil having the
characteristics:
Plasticity index P1 > 20,
Moisture content w 2 40%, and
Undrained shear strength s < 500 psf
F. Soils requiring site response See Section 20.3.1
analysis in accordance with Section
21.1
For SI: lit/s = 0.3048 m/s llb/1t2 = 0.0479 kN/m
https://earthquake,usgs.govlcnh/designmaps/us/report,php?template=mjnimal&latjlude=33 122160965421315&longltude=.117.2B390368782495&sitec... 1/8.
Design Maps Detailed Report
5 Section 11.4.3 - Site Coefficients and Risk-Targeted Maximum Considered Earthquake (ç,)
Spectral Response Acceleration Parameters
Table 11.4-1: Site Coefficient FD
Site Class Mapped MCE Spectral Response Acceleration Parameter at Short Period
S :5 0.25 Ss = 0.50 Ss 0.75 S5 = 1.00 S5 1.25
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1,1 1.0 1.0
ID 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of S
For Site Class = D and S. = 1.079 g, F = 1.068
Table 11.4-2: Site Coefficient F
Site Class Mapped MCE R Spectral Response Acceleration Parameter at 1-s Period
0 S1 0.10 :5 S1 = 0.20 S1 = 0.30 S = 0.40 S 2! 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1,0 1.0
C 1.7 1.6 1.5 1.4 1.3
D 2.4 2.0 1.8 1.6 1.5
E 3.5 3.2 2.8 2.4 2.4
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of S1
For Site Class = D and S1 = 0.416 g, F 1.584
W]
https://earthquake.usgs.gov/cn 216
11/juUu1/ Design Maps Detailed Report
1.1
Equation (11.4-1): SM$ FS5 1.068 x 1.079 = 1.153 g
uation (11.4-2): FS 1.584 x 0,416 = 0.659 g
Section 11.4.4 - Design Spectral Acceleration Parameters
Equation (11.4-3): S05 = % Sms = % x 1.153 = 0.769 g
Equation (11.4-4): SDI = % S,1 = % x 0.659 = 0.440 g
Section 11.4.5 - Design Response Spectrum
From Figure 22-12 T1 = 8 seconds
Figure 11.4-1: Design Response Spectrum
T: S1 S (0.4 + 0.6 T/T0 )
I
1<
-- To TS Ts: Si S
4
I
I I
I
0 in
I
I
I
i Tl<T~TL :S1 S0,/
TI T>TL.SDITLt
I I
S-0.440 (1
I I
I I
I I
I I
tn I I
I
$
I
p
I
*
I
I
I
I
I
I
I
I
I
I
I
I
To 114 1.00'O
Period. T(ec)
17.26390368782495&sltec... 3/6
1.153
.I1lju1Zu11 oeslgn Maps Lietallea Keport
7 Section 11.4.6 - Risk-Targeted Maximum Considered Earthquake (MCER) Response Spectrum
The VICE, Response Spectrum is determined by multiplying the design response spectrum above by
1.5.
Period. r (!e)
NO
4/6
ii,.,ui.uui uesign Maps Delallea Heport
Section 11.8.3 - Additional Geotechnical Investigation Report Requirements for Seismic Design
Categories D through F
Figure 22-7 143 PGA = 0.421
Equation (11.8-1): PGAM = FPGAPGA = 1.079 x 0.421 0.454 g
Table 11.8-1: Site Coefficient FpG
Site Mapped MCE Geometric Mean Peak Ground Acceleration, PGA
Class
PGA :5 PGA = PGA = PGA = PGA >
0.10 0.20 0.30 0.40 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1,4 1.2 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
(:1) Note: Use straight-line interpolation for intermediate values of
For Site Class = D and PGA = 0.421 g, FpGA = 1.079
Section 21.2.1.1 - Method 1. (from Chapter 21 - Site-Specific Ground Motion Procedures for
Seismic Design)
From Figure 22-17 '51 CRS = 0.963
From Figure 2218 61 CR1 = 1.017
17.28390368782495&sltec... 5/6
I il.UIUP I uesign Maps uetaflea Kepon
Section 11.6 - Seismic Design Category
Table 11.6-1 Seismic Design Category Based on Short Period Response Acceleration Parameter
VALUE OF SOS RISK CATEGORY
loril III IV
505 <0.167g A A A
0.1679 S S05 < 0.33g B B C
0.33g S05 < 0.50g C C D
05095os D 0 D
For Risk Category = I and S05 = 0.769 g, Seismic Design Category = D
Table 11.62 Seismic Design Category Based on 1-S Period Response Acceleration Parameter
VALUE OF S01 RISK CATEGORY
lorli III IV
S01 < 0.067g A A A
0.067g S < 0.133g B B C
0.1339 S01 < 0.20g C C ID
0.20gSo1 D D 0
For Risk Category = I and 0.440 g, Seismic Design Category = D
Note: When S is greater than or equat to 075g, the Seismic Design Category is E for
huildings in Risk Categories I, II, and III, and F for those in Risk Category IV, irrespective Othe above.
Seismic Design Category "the more severe design category in accordance with
Table 11.6-1 or 11.6-2° = D
Note: See Section 11.6 for alternative approaches to calculating Seismic Design Category.
References
Figure 22-1: https ://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2o1o_AsCE7_Fjgure_22 1. pdf
Figure 22-2: https ://earthquake.usgs.gov/hazards/designmaps/downloadsf pdfs/2010_ASCE-7_Figu re_22-2. pdf
Figure 22-12: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010 ASCE-7 Fig ure_22-12.pdf
Figure 22-7: https ://earthquake.usgs.gov/ hazards/designmaps/downloads/ pdfs/201Q..ASCE-7_Figure22-7. pdf
S. Figure 22-17: https://earthquake.usgs.gov/hazards/designmaps/dowriloads/pdrs/20 1O_ASCE-7_Fig ure_22-17.pdf
6. Figure 22-18: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/zo 1O_ASCE-7j9g ure_22- 18.pdf
6/6
DATE ____________________ SHET
10 1
I I IGINfEUD TO IXCIfD iXPiU1rrnN • :
* ENGR -
- •1• ---- - JOB NO
PROJECT i44o JJb Pk 1 ___ I I
-. ___________ - _____ ---- ______ ___.._.•
I.;..::.it .I
7,4
- I . •i• • --I---------
- - 3 •
I • • • I • I • • • •
• •;•.
Is
IID-. -. '•_• 1' - I •. htS 74 7 - 2 --.
-*--.--_- - -
- • - _____ •1 - Z'•l i-oj'xc. zP- •tCPT-6,. -
-
F : :1 !1OirJc - • •
-•-:--:--•• --•-•t --•-----1 -•- -1 -;
- I l I • I • • • I. • -'--s -C • • -•
• I • •
1
I L+ L. r t t I
— ._-.. ci-co 2,- -+.-.i•• -------------L L—. - -
I 1 T/c-- '3i k3iLL Cc%.4;t-' &/z ,*. 3c4
(5i-/Ac 1
- * r
ar
'
°' r (o'4o 4 .
I . •
$
i
4L0 &CR4cI C4f IWI, 'LI -2T# 2-.4
•- .
I •
1 .. I:, ••
w4M
31 t.5 - PC Vill
LA/j,
Cc47 SSc4z_ t" II
I 1
I I I I f
Results for LC 1, D+Lr
Member Axial Forces (k)
V-direction Reaction Units are k and k-ft
SK-4
I Dec 6, 2017 at 3:42 PM
Awning Frarne.r3d
ax
Results for LC 2, 1 .20+t6Lr
Member Axial Forces (k)
V-direction Reaction Units are k and k-ft
SK-5
Dec 6, 2017 at 3:43 PM
Awning Frame. r3d
Beam: . I1J73
(I
AISI SI00-12: LRFD Code Check
Max Bending Check 0.205 Max Shear Check 0.001 (y)
Location 2.5 ft Location 0 ft
Equation C5.2.2-1 Max Defi Ratio L/10000
R (D6.1.1) Not Used
Fy 33 ksi Lb 5 ft 5 ft A eff. (Fy) .283 inA2
0 4.63 k KLIr 98.172 41.52 A eff. (Fn) .309 inA2 0*Tn 10.098k Iyeff. .127inA4
0 'Mny .275 k-ft L Comp Flange 5 ft Sy eff. (L) .236 jA3 0 .917 k-ft Torque Length 5 ft Sy eff. (R) .117 jA3 0 'Vny 2.643 k Iz eff. .71 jA4 0 *\Jz 2.362 k Sz eff. (T) .392 ,A3
Cb 1.316 Sz eff. (B) .392 inA3
Q- I
ft
in
ft
1 k-ft
Mz
Irr
k-ft
Shape: 362S162-43
Material: A570 Gr.33 0y ----------- in
ength: 5
I Joint: N2 Dz J Joint: NI
LC 2: 1.2D+1.6Lr
Code Check: 0.205 (bending) -.022 0 ft Report Based On 97 Sections a
.934 at 2.5 ft
.002 at 0 ft
Vy. k Vz k
-.002 at 2.552 ft
A —:
0 at 0
My k-ft
-.005 at 2,5 ft
2.746 at 2.5 ft
.148 at 2.5 ft
fe —ksi ---- ki
-.148 at 2.5 ft
0 at 0 ft
-- ksl
17
iI
C
AIS!SIOO-12: LRFD Code Check
Max Bending Check 0.251 Max Shear Check 0.001 (y) Location 2.5 ft Location 0 ft Equation C5.2.2-1 Max Dell Ratio UI 0000
R (D6.1.1) Not Used
Fy 33 ksi Lb 5 ft 5 ft A elf. (Fy) .283 in'2 0 4.63 k KL/r 98.172 41.52 A elf. (Fn) .309 lnA2
0 'Tn 10.098 k ly eff. .127 jn'4 .275 k-ft L Comp Flange 5 ft Sy elf. (L) .236 jn"3 .917 k-ft Torque Length 5 ft Sy eff. (R) .117 jrIA3
0 'Vny 2.643 k lz elf. .71 in"4 0 'Vnz 2.362 k Sz elf. (T) .392 jA3
Cb 1.316 Sz elf. (B) .392 jA3
Q_
Beam:
ft
'joint:
ft
ksi
ft
Shape: 362S162-43
Material: A570 Gr.33 Dy fl
)ngth: 5
N2 Dz in J Joint: NI
LC 3: 1.2D+1.OW+0.5Lr
Code Check: 0.251 (bending) 027 at 0 ft Report Based On 97 Sections
1.143 at 2.5 ft
.002 at 0 ft
Vy k Vz k
-.002 at 2.552 ft
A•• Ek
0 at 0 ft
1 k-ft MZi1
prk-ft My
k-
-.006 at 2.5 ft
3.362 at2.5ft
.181 at 2.5 ft
ksi ft
-181 at 2.5 ft
0 at 0
fa ksJ
Company : 19
RSA Designer : Dec 6, 2017
4:35 PM
Job Number :
Checked By.
TECH NOLOGIEr, ModelName
Cold Formed Steel Properties
I hI e.-11 t iu.ii kk. r1....... 1% s,_._.,.___
ri
-_- -
A570Gr.33 1 29500 11346J .3
-- .
.65
-
.49
U - - • Ut t I 331 52 I 2'. A6Q7'CiEGi5i, 29500 . 14346 I! ... . .49 _L__55 70
Cold Formed Steel Design Parameters
I I nn, I ktfIt I h.,..t I I-n., I I. I •__ II... •,...- ,'_ _... - - -....- . . - - - - - - - --- .-. .•. a. t.LS.S - Jfl.,J k4lljat.aflfl... IA! .Ls t.kslfl
_]ILi fjI
Member Distributed Loads (BL C 1: D)
PA-,.,i kJ ee..... IA
1
-
Ml ]
- -- -- --------
V 1 -021
_. .-.--.n.-.---•p.- ..r' •
-021
ID
0 0 - 2 IL Y1 -021 - 021 0
C Member Distributed Loads (BLC 2: Lr)
- . .. .-_.. ..s
• ..tcauulnn-t,.-.r-.-...;-,pj,JJ.jJ I
._!:iii— _Iyr-., -is 11 1fli 11 MIN
Member Distributed Loads (BLC 3: WI
-. 1"ffl ____________________
Basic Load Cases
RI ( flc.,rriItkv, V V 7
._• ra:ir: -
-- •--.- ..-.- ------.. AL.ac.s,IraI. .MINOR IL I IiJfn I- I[.....J ---Iii MUNIME
Load Combinations
M—iftfl— CA— DII4
:u_- rhl_ nflni1SU.__
EEFIflhifl
RISA-3D Version 14.0.1 [A:\...\..\..\CALCSwning Frame.r3d] Page 1
Company : 20
INRISA Designer : Dec 6, 2017
4:35 PM Job Number :
TECHNOLOGIES Model Name : Checked By.
Load Combination Design
DescnDtI, ASIF CD ARIF ApmirAI-1nt RnIId(nId Few Wnwl Al........ .4
I D+Lr Yes Yes Yes Yes Yes YesYes I Yes
- 12D+1 6L? - Yë1 véit Ye'L Yesi. 'Yes I Yi Yé LYiS
3 Ii .2D+ I.0W4-0.5Lr t YesJ Yes Yes - Yes Yeé Yes Yes I Yes
_Joint Deflections
-
i
- L__
I
_Jrn aoei
NI
xlinj YJnJ ZiJrjI X Rotation frad patiqçijad LotatIojiftac 0 - 0 0 0 0
- I N2 -.0021 -0I5 0 - 0 3 I N3 0 0 0 0 0 0 I N4 0 -0I& 0 0 1 0* 01
5 I N5 -.002 -.008 0 0 0 -2.486e-4
IL 'N6_ I - 10 -008 0 0 0 2'476 7 2 Nl 0 0 0_0 0 0
N2 003 -QZ2 01 i OL_ 0L _L 2 N3 0 0,, 0 0 0 10I 2 N4 - 0 022 0 0
11 2 N5 -.003 -.012 0 0 0 -3.635e-4 2 N6 _2 L_0 T 0I2t L 0 - 0 3 6124 13 3 NI 0 0 0 0 0 0
003 -O27 o - o r
15 3 N3 0 0 0 0 0 0 16L't____3 N4L_ _JO -027 0 _o_ 17 3 N5 -.003 -.014 1 0 0 0 -4.45e-4 18 i3 N6__ _0_ 015 O' :01 -4-4214'
Member Section Forces
LC Member Label Sec A,dallkl vShrtk1 , Shwfk1 T,vriifkJt
EUN 1__-I
--
-
I I I I
II_
Ell- 011111,1111 Ilm
• i s
____
MAIN
I1_ U ..__S
1 W . _iW ki-_. ------------------------ L.,r
yF.
RISA-3D Version 14.0.1 (A:\...\...\...\CALCS\Awning Frame. r3dj Page 2
Company : 21
ERNRESA
Designer : 6,2017
4:35 Job Number : PM
CheckedBy.
TECHNOLOGIES Model Name
0 Member Section Forces (Continued)
LC Member Label Sec *, qhAarfkl 7 RhonrIld TrwneWJt1 t.w ,
_i66 1 0 0_01 0
23 3 .166 0 0 0 0 0
166 10,'L - cL 0 40' . 0
25 5 .166 0 __ 0 0 0 2L J_ MB 17 094 0 - *04 0 043' I
27 2 -.166 .055 0 0 0 -.003
28
r 162_ 017 0 0 ---7.026:
29 4 -.158 -.021 0 0
___
0 -.025
30 - 5 - 154 - 059 - 0 01 0 0
31 1 1 M7 _j_ .188 0 0 0 0 0
'r2j 188 0. - 0 - 0 0
33 3 .188 0 0 0 0 0
-- j _i 88_ 0 0 0 0 0
35_ 5 .188 0 0 0 0 0
3 11 p243 086' if 10 0 *0
37 2 -.237 .03 0 0 0 -.037
3 3'-'232 025 I 0 - 0' 0
- -0381
39 - 4 -.226 -.081 0 0 0 -.005 (401 _±221 - I ___-137 01 0 L__0631
412 M2 1 -.002 0 0 0
-
0 0
L '002 101 0 i_________ 43 1 3 -.002 0 0 0 0 0
- 002 L 0 - 0 0 Ok
45 _______ 5 -.002 0 0 0 0 0
46 T I _MS 0 002 1'01 01
47 2 0 .002 0 0 0 -.002
4 i 3i 9341 *0021 0* 0 - 0 - 005
49 4 .934 -.002 0 0 0 -.002
51 934__- L21 0* 0 QL
51 2 M4 j_ -.777 0 . 0 0 0 0
052 2 .1.7Z7
53 3 -777 0 0 0 0 0
54 0 - _0 0
5 -.777 0 0 0 0 0 i 242 j 0 0 I 0_- 57 2 .242 0 0 0 0 0
- _242 *0I
59 4 .242 0 0 0 0 0
_242j 0 0' 0 0__ jo
61 2 M6 1 -.248 .137 0 0 0 !03
_______________ -__242 I _0814 01 0 - _0 -.005,
63 •••_•
3 -.237 .025 0 0 0 -.038
4 231 _03 '0 0 0 - 037
65 5 -.226 -.086 0 - 0 0 0
66 _L j 275 0 '01 07.7
67 2 .275 0 0 0 0 0 -
_ - 275 0 0' '0 _Q_
69 _4_.275 0 0 0 0 0
' 275 i 'L oj 0 '0 10.
71 3 Ml _L. -.298 .106 _O 0 0
za. ...2_ 291 037' LO_ 0'
73 - - 3 -.284 -.031 0 0 0 -.047
RISA-3D Version 14.0.1 [A:\...\...\...\CALCSAwning Frame.r3d] Page 3
W.
22 Company : Dec 6, 2017
ORNRISA,
Designer 4:35 PM JthNumber Checked By
1ECHWOLOGESModeIName
0 Member Section Forces (Continued)
I I IIk1 j , fit - -
• • • 11oi--ioi w JLLLf]
IiI_ I I I I I • 1 I,i1LiL_ijei..
- W*_.,1.:i'. • - S -
INIVIIII I-,. L_I
_ • IM
• • •
WMEM
__iai11ji_'._•i_ J_•i La • • ,
"__LD](!1r_!1_1
_
• • •
-Ii- riii
IM • •
fi11 !r•) fj) ,i_I_
_
• • •
I 111' I 11, 11 MMM sm- - wmw Sam I I I__II•.
EMM •__• MEIMME.
WOM 'am ON " '-• IflI •
-- _ -'ir•__ IMM
I I I I MEMI
WRIMMMIM II'
Member Cold Formed Steel Code Checks
I ( Mmhr SSw I IC M I ,e4ft1 I If I ...-trn r. e*T..tL1 ...._ "I. f'-.- l_.._
1 1 Ml 362S16243 060 2j2 035 2.512 y 6878 10098 173 97 18186 10512
-M2 L43 OOQ '1000± rni.... '7 859t 10 098 j73f _j j_ ci 3 1 M3 362S162-43 .142 2$ .001 0 4.63 10.098 .275 .917 1.316 .6 .6 C52.2..1
jj M4 3625163 - _053 _Q_ ! _000 Q_ 6_6691 101098 173 97 1 L-0 -,;6:
.L L M5 362516243 .024 _0 .000 0 6.812 10.098 .289 .947 1 £ L 362S16243 062 _Q 035 Q_ 6818' 10 098 j73 ,97, V818 '6 C5'l V
7 1 M7 362S16243 .024 0 .000 0 v 7.784 10.098 .289 .969 1 .6 .6 C5.2.2.
8 2 Ml 362S16243 081 2 ;--'052'-2!5.l2j 6_878e i0098 .-. _173 W F818 61 tl C5__12
9 2 M2 362816243 .000 0 .000, 0 v 7.859 10.098 .173 .97 ...1 . CS. .2..
10 M3 362S 162;43 205 JL '001 y r_63 101Q98 275k 917t 1316 '6 _L 11 2 M4 362S16243 .077 0 .000 0 y 6.669 10.098 .173 .97 1 .6 .6 C5.1.2.. J2. 21 M5 362S16243 _036 _Q_ p000 6812 tO 098 _289 947 .J ...& C522e
13 2 M6 362S162-43 .090 0 .052 0 y 6.878 10.098 .173 .97 1.818 .6 1 C5.1.2..
14 M7 3625162.43 035 .0 000 j t;,7.78 10T098 .289 .969t
IT 3 Ml 362S162-431.107 2.512 .063 2.512 y, 6.878 10.098 .173 .97 1.18 6 1 C5.1.2..
RLSA-3D Version 14.0.1 [A:\...\...\.. .\CALCSAwning Frame.r3d] Page 4
101
III
23 Company : Dec 5, 2017
RS' Designer 4:35 PM
Job Number Checked B__
TECHNOLOGIES Model Name
0
Member Cold Formed Steel Code Checks (Continued)
IC Member Shaze UC Mx Lndftl ShparUC Lnrlftl flirl hi*Pn!k1r *Tr&l flhi*Mnu ñhiPj,, Ph
ifi a M2 362S162-431 00O I—zlT" 000 7859b1O098 173 97
17 3 M3 362S162-431 .251 2.5 .001 0 4.63 10.098 .275 .917 .6
362S16243 094 Q 000
C5.2,2,
M4 6669' 10rO98 173 97
3 M5 2S13) .044 Q .000 L19 Q•y 6.812 10.098 .289 .947
Z
£ M6L 110 '063k
5.2.2..
2Q Q 6878r1o098 j73 97 1
3 Mi 362S162-43j .043 0 .000
C592
21 0 y 7.784 10.098 .289 .969 . C5,2.2.
Joint Reactions
LC Joint Label X. (ki V C) 7 IIc )( M Ik..fti MV fItft IA7 tfr..f*1
I I NI .639 .001
..-.--.-
0 0 .0 0
2 _t N3 639 305k 0 0
3 1 Totals: 0 .307 0
jj. 1 1COG1(fti X_25 Y__5_ —,Z: OT
5 1 2 Ni .934 .002 0 0 0 0
L N3 -_-934 447L_- o_T. r_.o' - 7 2 Totals: 0 .448 0 _________ _________
8 __2k - __________ X2 W95k - Z0 J i_
9 3 NI 1.143 .002 0 0 0 0
11 OL, _3_I N3 1-1143L - _54iL 0 LTi1O - 0 0
11 1 3 Totals: 0 .549 0
12 3 QOGJ(ftL X 42L5 Yt951
0
RISA-30 Version 14.0.1 [A:\...\...\...\CALCS\.Awning Frame.r3d) Page 5
www.hlltius Profis Anchor 2.75
Company; Page;
Specifier: Project;
ddress:
C~Phone
Sub-Project I Poe. No.:
I Fax: Date: 1216/2017 E-Mail:
Specifiers comments:
Anchor type and diameter KWIK HUS EZ (KH EZ) 318 (3 114) - —
Effective embedment depth; her = 2.500 in., h = 3.250 In.
Material: Carbon Steel
Evaluation Service Report ESR-3027
Issued I Valid; 2/112016112/1/2017
Proof: Design method ACI 318 / AC 193
Stand-off installation: - (Recommended plate thickness' not calculated)
Profile: no profile
Base material: cracked concrete, 2500 f0'= 2500 psi, h m 12.000 in.
Reinforcement: tension; condition B, shear: condition B. no supplemental splitting reinforcement present
edge reinforcement: none or < No. 4 bar
Seismic loads (cat, C, D, E, or F) no
Geometry (In.] & Loading (lb, ln.lbj
Z
0
\
0
Input data and results must be checked for agreement with the existing conditions and for plauslblttlyl
PROFIS Anchor ( c ) 2003-2009 Hilti AG. FL-9494 Schaan HIW is a registered Trademark of HIM AG. Sthaan
www.hlltius Profis Anchor 2.7.5
Company: Page: 2
Specifier Projectr
CP~hone
ddress: Sub-Project I Pos. No.:
I Fax: I Date: 12/6/2017
E-Mail:
2 Proof I Utilization (Governing Cases)
Design values fib] Utilization
Loading roof Load Capacity FIN Pv 1%] Status
Tension Concrete Breakout Strength 1100 1345 82i- OK
Shear Concrete edge failure in direction y+ 223 508 444 OK
Loading --ON py Utilization P v Status
Combined tension and shear loads - 0.818 0.439 —513 97 OK
3 Warnings
Please consider all details and hints/warnings given in the detailed reporti
Fastening meets the design criteria!
4 Remarks; Your Cooperation Duties
Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hllti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried Out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Q
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by HuLl on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. 1-filti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you,
161
Input data and results must be checked for agreement with the existing conditions and for plausibittyf
PROFIS Anther (c ) 2003-2009 HUll AG, FL-9494 Sthaan HUll Is a registered Trademark of HUll AG Sthaan
(ity of
Carlsbad
Print Date: 12/05/2018 Permit No: PREV2018-0067
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
1950 Camino Vida Roble
BLDG-Permit Revision
2120931200
$ 0.00
Work Class: Residential Permit Revisi Status: Closed - Finaled
Lot #: Applied: 03/13/2018
Reference #: Issued: 04/03/2018
Construction Type Permit 12/05/2018 Finaled:
Bathrooms: Inspector:
Orig. Plan Check #: CBC2017-0648 Final
Plan Check #: Inspection:
Description: BUCHANAN: REMOVE AWNING FROM SCOPE
Applicant: Owner:
DRILLING AND FOUNDATIONS INC BSP CACC LLC
TIM SEAMAN
P0 Box 5955 1900 Main St C/O Allen Matkins Leck
CHULA VISTA, CA 91912-5955 IRVINE, CA 92614
619-993-8846
FEE - AMOUNT
MANUAL BUILDING PLAN CHECK FEE $150.00
Total Fees: $ 150.00 Total Payments To Date: $ 150.00 Balance Due: $0.00
Building Division
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov
CONTACT INFORMATION:
Name T6 M Phone
Address /127 !/•/ii 5ieO
PLAN CHECK REVISION OR Development Services kL city of DEFERRED SUBMITTAL Building Division
Carlsbad APPLICATION 1635 Faraday Avenue
760-602-2719
B-I 5 www.carlsbadca.gov
Original Plan Check Number L76 2 o) 7 - Plan Revision Number Pcey 2oi8-00 7
Project Address 950 VWIA bi
General Scope of Revision/Deferred Submittal: O
Email Address
I9 29 Fax
City Zip j93Z
T' P[1(/f3 tCOi"
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1. Elements revised: E?I Plans 0 Calculations LII Soils LI Energy LI Other
2.
Describe revisions in detail
3.
List page(s) where each
revision is shown
,0 'Jv1C)V&d 4,V/1 ['A J,/
Does this revision, in any way, alter the exterior of the project? LI Yes No
Does this revision add ANY new floor area(s)? Yes No
Does this revision affect any fire related issues? Yes No
Is this a complete set? Yes LI No
signature Date S //3 /
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602- 2719 Fax: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
E s G 1.[,
A SAFEbutorip
DATE: March 21, 2018
JURISDICTION: Carlsbad
U APPLICANT -ru RIS.
PLAN CHECK#.: CBC2017-0648 REV
PROJECT ADDRESS: 1950 Camino Vida Roble
SET: •I
PROJECT NAME: Canopy Addition Revision
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
11 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LII The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: - Telephone #:
Date contacted: Email:
Mail Telephone Fax 5~son
REMARKS: PREV20I8-0067.
By: Kurt Culver Enclosures: Previously-approved
EsGil plans
LIGA LIEJ LIMB F1 PC 3/15/18
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
/
Carlsbad CBC2017-0648 REV
March 21, 2018
[DO NOT PAY— THIS IS NOTAN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK#.: CBC2017-0648 REV
PREPARED BY: Kurt Culver DATE: March 21, 2018
BUILDING ADDRESS: 1950 Camino Vida Roble
BUILDING OCCUPANCY:
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Awning/Remodel
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code Icb IBY Ordinance
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance 'V I $150.00I
Type of Review: LI Complete Review LI Structural Only
F-1 Repetitive Fee
1W i Repeats
* Based on hourly rate
LI Other
LI Hourly
EsGil Fee
1 Hr. @ *
$120.00 I $120.00I
Comments:
Sheet 1 of 1
A
BNVE STRUCTURAL • CIVIL .SURVEY • LAND PLANNING
9449 Balboa Avenue, Suite 270 .San Diego, CA 92123
Phone (619) 299-5550 • Fax (619) 299-9934
www.bwesd.com
ENGINEER: Dane Hansen
DATE: March 7, 2018
PROJECT NUMBER: 13020A.1
\'s
STRUCTURAL CALCULA1
FOR
1950 Camino Vida Roble AwnurJc( , ;~'C*11
Carlsbad, CA
Table of Contents:
Project Loads ....................................................................................................................... 1
FramingDesign.................................................................................................................10
cfESS,oA
DATE SIGNED: 3/7/18
Prepared for
idStudios
236 S Sierra Avenue, Suite 110
Solana Beach, CA 92075
r3NV;DATE SHEE I ! NGgNIUlD TO (KIlO IXPICTAflONS I 1 I
ENGR! --- _JOB-NO.
C) PROJECT'
1 _________________ •1 ' - -r- ---f
'-
Qejo L.A-óJ'
IIf I I -i I s/.yrJt.1 4;
-- L L6 -sô, c, itIl ;21:
I1rI 1l I I
LL iL
_ItJiiiF t H
__ 1t111 14 iv LHi± FJfJ
I__I_I ¶-. I 4 f-1-'T- - _[ L ! II I -- • ; f ----t- -4-- I I I I _-- L- 1 -
J :
1T T TN 1 4T r
-44
IYTr Yi
-1
sk
I iI I ' --1 °S jotççH
Tj
J H ThT Th: J} 4TF T
--
4
I DITEIII LB''E1SH'ELT_....
I I l I JNGrn11110TO1CIDmECTAUONSI I J
-ENGR I I L4 JOB NO I IItt•• 4. I
II . . PROJECT 0
- I •!i I
LLJ± L •1.-
I&
0 Ic ~6 c k ?0-4-
CJ 1 f 4
'I *I I•, •1 I I
I
'J•'jW 11JiJ .?
Lit 'fl ±1+
Lo IA 4 H tj :i t 1t jj
' t•• 1- 1 '
to
4
ti4 1
tt I t-' I 24crI I I
•k * Jç i47r I 1 • :
j_•: Lit
H
1 t ti , t1
. LL± •1••tW t•j±L+1J••L
i Tt I1tdiji4LL!
4 i
~4
T11 1
11liu!2u1 I Design Maps Summary Report
IJSGS Design Maps Summary Report
User—Specified Input
Building Code Reference Document ASCE 7-10 Standard
(which utiizes USGS hazard data available in 2008) 0 Site Coordinates 33.122160N, 117.2839°W
Site Soil Classification Site Class 0 - "Stiff Soil"
Risk Category 1/11/111
USGS—Provided Output
0
S5 = 1.079 9 SMS = 1.153g S= 0.769g
s1 = 0.416 g S = 0.659 g SDI = 0.440 g
For information on how the SS and SI values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP building code reference document.
MCE, Response Spectrum Design Response Spectrum
Peqi,d. I (s) Peric4. I (see)
For PGAM, TO C, and C 1 values, please view the detailed report,
0 ough this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the
racy of the data contained therein. This tool is not a substitute for technical subject-matter knowledge.
3
.28390368782495&s... 111
ljl.SU!2U1 ' Uesign Maps (Jetalled Report
IJSGS Design Maps Detailed Report 51
ASCE 7-10 Standard (33.122160N, 117.2839°W)
Site Class 0 - "Stiff Soil', Risk Category I/Il/Ill
Osection 11.4.1 - Mapped Acceleration Parameters
Note: Ground motion values provided below are for the direction of maximum horizontal
spectral response acceleration. They have been converted from corresponding geometric
mean ground motions computed by the USGS by applying factors of 1.1 (to obtain S) and
1.3 (to obtain 53. Maps in the 2010 ASCE-7 Standard are provided for Site Class B.
Adjustments for other Site Classes are made, as needed, in Section 11.4.3.
From Figure 221. '' Ss = 1.079 9
From Figure 22-2 ' = 0.416 g
Section 11.4.2 - Site Class
The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or
the default has classified the site as Site Class D, based on the site soil properties in
accordance with Chapter 20.
Table 20.3-1 Site Classification
Site Class or
J\. Hard Rock >5,000 ft/s N/A N/A
B Rock 2,500 to 5,000 ft/s N/A N/A
Very dense soil and soft rock 1,200 to 2,500 ft/s >50 >2,000 psi
Stiff Soil 600 to 1,200 ft/s 15 to 50 1,000 to 2,000 psI
Soft clay soil <600 ft/s <15 <1,000 psi
Any profile with more than 10 ft of soil having the
characteristics:
Plasticity index P1 > 20,
Moisture content w ? 400/6, and
Undrained shear strength s < 500 psI
F. Soils requiring site response See Section 20.3.1
analysis in accordance with Section
21.1
For SI: lft/s = 0.3048 rn/s llb/ft2 = 0.0479 kN/m2
https://ear1hquake.usgs.govIcnh/deslgnmaps!us/reporLphp?template=mininial&latitude33 .122160965421315&longltude=-117.28390368782495&sitec... jIG
i,ju,u' I Design Maps Detailed Report
5 Section 11.4.3 - Site Coefficients and Risk-Targeted Maximum Considered Earthquake (Mg)
Spectral Response Acceleration Parameters
Table 11.4-1: Site Coefficient F
Site Class Mapped MCE , Spectral Response Acceleration Parameter at Short Period
S :5 0.25 S = 0.50 Ss = 0.75 55 = 1.00 Ss a 1.25
A 0.8 0.8 0,8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 L 1.1 1.0
E 2.5 1.7 1.2 0.9 0,9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of S.
For Site Class = D and S. = 1.079 g, F = 1.068
Table 11.4-2: Site Coefficient F
Site Class Mapped MCE Spectral Response Acceleration Parameter at 1-s Period
0 S1 :5 0.10 S1 = 0.20 S = 0.30 S1 = 0.40 S 2t 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.7 1.6 1.5 1.4 1.3
0 2,4 2.0 1.8 1.6 1,5
E 3.5 3.2 2.8 2.4 2.4
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of S1
For Site Class = D and S = 0.416 g, F, = 1.584
E*
https://earthquake.usgs.gov/cnh/designmaps/us/report,php?template=mlnjmal&latitude33. 122160965421315&longitude=-117.28390368782495&sitec... 216
1iI•Ju1Zu1 I Design Maps Detailed Report
1.1
Equation (11.4-1): FS5 = 1.068 x 1.079 = 1.153 g
CE
quation (11.4-2): FS1 = 1.584 x 0,416 = 0.659 g
Section 11.4.4 - Design Spectral Acceleration Parameters
Equation (11.4-3): Sos = % Sms = % x 1.153 = 0.769 g
Equation (11.4-4): S0 = % S,,11 = % x 0.659 = 0.440 g
Section 11.4.5 - Design Response Spectrum
From Figure -22-12131 TL = 8 seconds
Figure 11.4-1: Design Response Spectrum
I
I<TQ: S.S(0.4 +06TITD )
-- TTT5:S1 5
I
i T,<T~TL:S1 S01/T
0 T>TL:SI=SOITLIP tn
I
I
$
$
ID
S,ø0,440 41 I
.4
I
I
I
I
$ I
$
I
I
I
I
$
I
I
Ui 4
$
I
I
I
I
ID
$
$
$
4
$
I
4
S
4
I
I
-O.1 14 1Q572 1.000
Period. T (sec)
N]
httpslIearthquake.usgs.gav/cn 7.26390368782495&sltec.-. 316
1,
iit.uiui L)eslgn Maps uetailed Report
7 Section 11.4.6 - Risk-Targeted Maximum Considered Earthquake (MCER) Response Spectrum
The MCE Response Spectrum is determined by multiplying the design response spectrum above by
1.5.
Peciod. t (e)
ttttps://earthquake.usgs.gov/cnlldeslgnmapsluslreportphp?ternplate=minjmal&latitude=33,1 2216096542131 S&Iongitude=- 117.28 390368782495&sitec . . . 4/6
iii.oiuii ueslgn Maps L)elalleci Keport
Section 11.8.3 - Additional Geotechnical Investigation Report Requirements for Seismic Design
Categories D through F
From Figure 22-7141 PGA =0.421
Equation (11.8-1): PGAM = FPGAPGA = 1.079 x 0.421 = 0.454 g
Table 11.8-1: Site Coefficient FPG&
Site Mapped MCE Geometric Mean Peak Ground Acceleration, PGA
Class
PGA PGA = PGA = PGA = PGA
0.10 0.20 0.30 0.40 0.50
A 0.8 0.8 0.8 0.8 0.8
6 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of PGA
For Site Class = D and PGA = 0.421 g, FPGA = 1.079
Section 21.2.1.1 - Method 1 (from Chapter 21 - Site-Specific Ground Motion Procedures for
Seismic Design)
From Figure 22-17' CRS = 0.963
From Figure 22-1801 C 1 = 1.017
E*
https://ear1hquakeusgs.gov/cn1 516
ii/.,u/u-I I uesign Maps Lietallee Keport
Section 11.6 - Seismic Design Category
Table 11.6-1 Seismic Design Category Based on Short Period Response Acceleration Parameter
VALUE OF sc
RISK CATEGORY
loril III IV
5Ds<0•167g A A A
0.167g S < 0.33g B B C
0.33g S,5 < 0.50g C C D
05OS 5 D 0 D
For Risk Category = I and SDS = 0.769 g, Seismic Design Category = D
Table 11.6-2 Seismic Design Category Based on 1-S Period Response Acceleration Parameter
VALUE OF SDI
RISK CATEGORY
or III IV
SDI < 0.067g A A A
0.0679 S01 < 0.133g B B C
0.1339 sr, < 0.20g C C 0
0.209S01 D D D
For Risk Category = I and 5 = 0.440 g, Seismic Design Category = D
Note: When S is greater than or equal to 0.75g, the Seismic Design Category is E for
buildings in Risk Categories I, II, and III, and F for those in Risk Category IV, irrespective Othe above.
Seismic Design Category "the more severe design category in accordance with
Table 11.6-1 or 11.6-2" = D
Note: See Section 11.6 for alternative approaches to calculating Seismic Design Category.
References
Figure 22-1: https ://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010 ASCE-7 Figure 22-1. pdf
Figure 22-2: https ://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010 ASCE-7 Figure 22-2. pdf
Figure 22-12: https://earthquake. usgs.gov/hazards/designmaps/downloads/pdfs/2o1o_AscE7Fjgure2212.pf
Figure 22-7: https ://earthquake.usgs.gov/hazards/designmapg/downloads/pdfs/20 1O_ASCE-7_Figure_22-7. pdf
Figure 22-17: https://earthquake. usgs.gov/hazards/designmaps/downloads/pdfs/20 1O_ASCE-7_Figure_22-1 7.pdf
Figure 22-18: https://earthquake. usgs.gov/hazards/designmaps/downloads/pdfs/20 10_ASCE-7j1gure_22-18.pdf
01
616
Aill
4 . 4 IMGINtUVPTXUSOVXIUATIOM1
ENGR
Q 'PROJECT I
SHEET H I -JOB NO-
., ..
I 14 4.. I tj -
I I I •_:; .__
4 -
TI' 1t .4i 11
f 1J/TE
Hcck1 t.1
r- -r-±f rtrrrr
I ' 4-•I t I - •• f 4 3 - -t 1 j I I-- i 1
r UtA*JC 1 H1
jk
kwl
H. I~4f IC( t. • - I
- r1
III u lj.i..... j1 f III ti j r j4) I
. . • - TT , fT1
I I II
-\ 1I- - I / • • • I I 3 --
- I 4 i H H
4-4 ______ 1 • •i I
f t ..TTT
I II.' -I Jil 1L
ESR-2269 I Most Widely Accepted and Trusted Page 6 of 14
TABLE 3—ALLOWABLE LOADS FOR FASTENERS DRIVEN INTO NORMAL-WEIGHT CONCRETE124 11
SHANK MINIMUM
FASTENER FASTENER DIAMETER EMBEDMENT ALLOWABLE LOADS (Ibf) DESCRIPTION (Inch) DEPTH
(Inches)
Concrete _Compressive _Strength: 2000 psi 4000 psi 6000 psi 8000 psi
Load Direction: Tension Shear Tension Shear Tension Shear Tension Shear
3/4 100 125 100 125 105 205 - -
Universal 1 165 190 170 225
___________
ii 2802 -
Knurled Shank X-U 0.157
1'!, 240 310 280 310 180 425 - -
1 '/2 275 420 325 420 - - -
3,2 100 155 100 175 105 205 135 205
is 165 220 180 225 150 300 150 215 Smooth Shank X.P 0.157
11/45 240 310 280 310 180 425 - -
112 310 420 - - - . -
For SI: 1 inch = 25.4 mm, 1 lbf = 4.4 N, 1 psi = 6895 Pa.
'Unless otherwise noted, values apply to normal weight cast-In-place concrete, Fasteners must not be driven until the concrete has reached the designated
minimum compressive strength.
'Unless otherwise noted, concrete thickness must be a minimum of 3 times the embedment depth of the fastener.
'This allowable load value for the X.0 fastener also applies to normal weight hollow core concrete slabs with fç of 6600 psi and m!nimum dimensions Shown In Figure 7, when Installed In accordance with Section 4.2.4.
4The fasteners listed In the table above may be used for static load conditions and for the seismic toad conditions described In Section 417, as applicable. The tabulated allowable toads apply to static toad conditions. For seismic load Conditions, the allowable loads must be limited in accordance with Section 4.1 items 2 and 3, as applicable.
'Applies to fastening of cold-formed sleet up to 54 mil thick using the X-P 22, X.P 27, X-P 34 and X-P 40 fasteners, respectively, for the 'J 1 04 and 1 inch embedment depths.
TABLE 4—ALLOWABLE LOADS FOR FASTENERS
DRIVEN INTO NORMAL-WEIGHT CONCRETE USING DX4(WIK'4
FASTENER
I
SHANK I MINIMUM
DESCRIPTION FASTENER DIAMETER I EMBEDMENT ALLOWABLE LOADS (ibf)
(inch) (Inches)
Concrete Compressive Strength: 4,000 psi I 6,000 psi
Load Direction: Tension Shear I Tension Shear
Universal X-U 47 P8 w/ 0,157 112 395 405 360 570 Knued Shank DX-lK
For ST: 1 inch = 25.4 mm, 1 Ibf = 4.4 N, 1 psi = 6895 Pa.
'X.0 Fastener is installed using the DX-KWiK drilled pilot hole installation procedure described in Section 4.2.5. 'Pilot holes must not be drilled until the concrete has reached the designated minimum compressive strength.
'Concrete thickness must be a minimum of 3 times the embedment depth of the fastener.
4Tha fasteners listed in the table above may be used for static toad conditions and for the seismic load Conditions described in Section 4.1 .7 as applicable. The tabulated allowable toads apply to static load conditions. For seismic load conditions, the allowable loads must be limled In aeeordance with Section 41.7, items
2 and 3, as applicable.