Loading...
HomeMy WebLinkAbout1957 LA COSTA AVE; CS; CB021037; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-21-2002 Commercial/Industrial Permit Permit No: CB021037 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 05/31/2002 1957 LA COSTA AV CBAD COMMIND C,5 Sub Type: Lot#: $40,000.00 Construction Type: Reference#: SPRINT CELL TOWER BLDG& EQUIPM INDUST 0 VN Applicant: Owner: BOB LASER 4909 MURPHY CANYON RD 92123 858244-1 026 Status: Applied: Entered By: Issued: Inspect Area: ISSUED 04/05/2002 AMA Plan Approved: 08/21/2002 Total Fees: $545.07 Total Payments To Date: $227.00 Balance Due: $318.07 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee lnspecto: $298.59 $0.00 $194.08 $0.00 $0.00 $8.40 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 FINA Date: Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF PFF (CFO Fund) License Tax License Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $20.00 $24.00 $0.00 $0.00 $0.00 $0.00 $545.07 NOTICE: Please take NOTICE that approval of your project includes the ~Imposition" of fees, dedications, reservations, or ot~r exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these tees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions OOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any f hi h i I i Tl E . h' w. h fli i i h I h PERMIT APPLICATION FOR OFFICE USE Oa:NL ~~() -i../ C)_.S 7 PLAN CHECK NO._();)_ t-Ojl - EST. VAL. /:ftq,,CJPD CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 ,,,,lak~lollM,.~o{l-['()JZ:d A-// Plan Ck. Deposit ----,tt-c.---"""''--1 • 00 Address (include Bldg/Suite #) Business Name (at this addre · Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Name Address City State/Zip Telephone# Name • Address City .AA 71.0 r~(). (,11os · 1./3'-,-sttl State/Zip Telephone # iGci' .t CON'm'ACTO~i' COM"ANV ill.Me" ' (Sec. 7031.5 Business and Professions Code; Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code! or that he is exempt therefrom, and the basis for the alleged An violation Q:f Section 7031.5 by any applicant for a permit subje s the applicant to a civil penalty of not more than five hundred dollars ($5001). "' ,/£_3'1,,, """-;,-~ ~ ~ Name State License # ~?,~:;1~~-~~9,~Y ___ _ Address License Class -~/3 _______ _ City State/Zip Telephone # City Business License # /,,/2~ V ,:;J.. ..3 Designer Name Address City State/Zip Telephone State License # _________ _ ca,,, '':iWOl!kERS' cOMPtiiSATIONc Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued . ."2[ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is ~ed. My worker's compensation insurance carrier and policy number are: Insurance Company.s:Y:&,/ FL'c-~.,,,.,:/""1/o--Policy Nou,,!.l/"tf'i?_3ae, :Zc'.) :z Expiration Date/_::;:,-~2: c9 ;\. (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1$1001 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the W rs' Compe Laws of California, sation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred e cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest and attorney's fees. SIGNATUR :7,i" ; 6WNElf•BUILDl!ii DECl:J\Riit101'1:· I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name I address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number).,_------------------------------------------------ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work):. ___________________________________________________________ _ PROPERTY OWNER SIGNATURE ______________________ _ DATE _________ _ '¢0M1>Letl!::rf11S SECTION101!"Nl1//'11E$/DEJV77At'liilil.bJl'IOil'~RMITSONL'I'.· Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ,,,.:· ;••eoNSTRucrtON"LENlil.NG'AGENCY!•·' I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _____________ _ LENDER'S ADDRESS, ________________________ _ '$',+'' APfLICJ\NT:CERTll'ICATION+ ' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt" of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over s•ott deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued bY. the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not com e ced within 180 ays from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is comme c for a period 180 days.,(Section 106.4.4 Uniform Building Code). DATE ~¥-_-~-r--~_O_Z---______ _ WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 04/03/2003 Permit# CB021037 Inspector Assignment: PD Title: SPRINT CELL TOWER BLDG& EQUIPM Description: Type: COMMIND Sub Type: INDUST Job Address: 1957 LA COSTA AV Suite: Lot 0 Location: APPLICANT BOB LASER Owner: Remarks: --- Total Time: Requested By: RICK Entered By: CHRISTINE CD Description Act Comment 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanlcal Associated PCRs/CVs lns12ection Histoty Date Description Act lnsp Comments 03/12/2003 15 Roof/Reroof AP PD 02/21/2003 34 Rough Electric PA PD 01/08/2003 13 Shear Panels/HD's AP PD 01/08/2003 14 Frame/Steel/Bolting/Welding WC PD 01/08/2003 15 Roof/Reroot AP PD OK TO ROOF/WRAP 12/31/2002 62 Steel/Bond Beam AP PD GROUT 2ND LIFT 12/17/2002 62 Steel/Bond Beam AP PD GROUT 1ST LIFT 12/02/2002 11 Ftg/Foundation/Piers AP PD RETWALLS 12/02/2002 12 Steel/Bond Beam AP PD SLAB 11/19/2002 11 Fig/Foundation/Piers AP PD GRADE BEAMS 11/19/2002 51 Excav/Steel/Bonding/Fence WC PD 11/15/2002 12 Steel/Bond Beam co PD 11/05/2002 11 Fig/Foundation/Piers PA PD PAD FTGS \ ♦ City., Carlsbad · Final Building Inspection Dept: Building Engineering CMWD St Lite Plan Check#: Date: 04/03/2003 Permit#: C8021037 Permit Type: COMMIND Project Name: SPRINT CELL TOWER BLDG& EQUIPM Sub Type: INDUST Address: 1957 LA COSTA AV Lot: 0 Contact Person: RICK Phone: 9097217073 Sewer Dist: Water Dist: ·;~·~~~~~~~················· .. ······ .. ············~~;~·································· .................... 7 ............................. . By: \Mo/ Inspected: ______ Approved: ___ Disapproved: __ Inspected Date By: Inspected: Approved: Disapproved: __ Inspected Date By: Inspected: Approved: Disapproved: __ Comments: -------------------------------- 11/14/2002 15:52 619-563-4548 HIRSCH & COMPANY PAGE 02 HIRSCH & COMPANY CONSULTING ENGINEERS • Since 1955 • Planning • Civil Engineering • Surverying • Envlronmont~I Rieb Botello Velocitel Inc 4909 Murphy Canyon Road, Suite 320 San Diego, CA 92123 Dear Rich, This is to Certify that the Lease Boundary at CARLSBAD VONS, Site No. SD4o:XC307B was staked oo the grouod according to the location !ihown on the Site Survey (Sheet LS-I) dated SeptembCl' 12, 2001. Sincerely, State of Ce.lifoniia Profeaaional Lltnd Surveyor License No. L 7130 3550 Camino ael Rio Nonh, Suite 305. San Diego, CA 92109-1740 • (610) 563-4545/FAX (619) 563-45.ta @ · xv~ LC'81 ZO/tl/11 HVA'lV zoo® TOO~ Velociret· N!Dvember 5, 2002 Project Nome: Project Number: Carlsbad Vons/ SPRINT PCS SD40XC307B Project Address: 7710 El Camino Real, Carlsbad, CA92009 Re: RFI at steel column anchor bolts To whom it may concern. The proposed W12x column anchor bolts are adequate with (4)-¾" diameter x 18" long at pod footing. Sincerely submitted, Chris Lee Project Engineer, 18071 Fitch Avenue, Irvine, CA 92614 USA T: 949.809.4999 f: 949.553.3919 www.veloclle~net 616£ £SS 6t6 XVd 01:91 ilH.L ZO/L0/11 EsGil Corporation 1n Partnersftip witft (jovernment for 'lJuiUing Safety DATE: 5/28/02 JURISDICTION: City of Carlsabd PLAN CHECK NO.: 02-1037 PROJECT ADDRESS: 1957 La Costa Ave. PROJECT NAME: Sprint PCS SET: II □ APPUSNT cc;[JURIS □ PLAN REVIEWER □ FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: cg] Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person 0 REMARKS: By: David Yao Enclosures: Esgil Corporation 0 GA O MB O EJ O PC 5/20 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 EsGil Corporation 7n rl'artnersliip witli (jovemttUnt for 'lJuiUing Safety DATE: 4/17/02 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-1037 PROJECT ADDRESS: 1957 La Costa Ave. PROJECT NAME: Sprint PCS SET:I D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gJ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gJ The applicant's copy of the check list has been sent to: Bob Laser 4909 Murphy Canyon Road, San Diego, CA 92123 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [gl Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Bob Laser Telephone#: (858)244-1026 Date contacted: t.tl11/02 (by:10--) Fax #:(<i-5ii1 .?YY /03:)...- Mail ---Tel~phone .,,.---Fax In Person 0 REMARKS: By: David Yao Enclosures: Esgil Corporation 0 GA O MB O EJ O PC 4/8 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad 02-1037 4/17/02 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO.: 02-1037 OCCUPANCY: B TYPE OF CONSTRUCTION: V-N ALLOWABLE FLOOR AREA: 8000 sf SPRINKLERS?: N REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED:4/17/02 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: telephone exchange ACTUAL AREA: 256 sf STORIES: 1 HEIGHT: OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 4/8 PLAN REVIEWER: David Yao This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 02-1037 4/17/02 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. • PLANS 1. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: ♦ Occupancy Group B 2. Provide a statement on the Title Sheet of the plans that this project shall comply with the 1998 edition of the California Building Code (Title 24 ), which adopts the 1997 UBC and the 1996 NEC. • SITE PLAN 3. Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. • ROOFS 4. A Class C roof covering is required. Table 15-A. 5. Specify roof slope. 6. Specify on the plans the following information for the roof materials, per Section 106.3.3: a) Manufacturer's name. b) Product name/number. c) ICBO approval number, or equal. Carlsbad 02-1037 4/17/02 • STRUCTURAL 7. The tower frame analysis appears to use the seismic force as lateral force. Does the wind load more than seismic force? Please check. 8. Detail 6/S4 shows all the weld size for the moment connection but the continuity plate and guess plate thickness and size did not specify on the detail. Please check. 9. Sheet 35 of the calculation shows the stiffeners are required. The detail 6/S4 appears to not show it. Please check. 10. Provide calculation to justify the roof framing plan, 3rd & 4th level framing plan and ground level framing plan. • ADDITIONAL 11. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 12. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: □ Yes □ No 13. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. Carlsbad 02-1037 4/17/02 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 02-1037 PREPARED BY: David Yao DATE: 4/17/02 BUILDING ADDRESS: 1957 La Costa Ave. BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-N BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. teleohone exchan 256 oer citv Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance I ..,, I Plan Check Fee by Ordinance l • I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee =8 Repeats Comments: D Other D Hourly ~---~I Hour• Esgll Plan Review Fee ($) 40,000 40,000 $298.591 $194.0BJ $1s1.21 I Sheet 1 of 1 macvalue.doc PLANNINC/ENCINEERINC APPROVALS PERMIT NUMBER CB($-/o3t: DATE b-/D -O'd" ADDRESS /C/5-r Y, LJ?B ;tel Av:?, RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR < < $10,000.00) OTHER Co l I sS / d-e-- PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLACE FAIRE COMPLETE OFFICE BUILDINC PLANNER_________ DATE ______ _ ENCINEE~btl~ DATE ({;j/O/cJJ oocs/Misforms/Plannlng Engineering Approvals " ll 1, !;I ] " C -" a. ~□□ ~□□ PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. C\?0(1'. \() 7:J] Planner Christer Westman Address lg S 1 b,A ~ .i\..,.e.,, Phone(760) 602-4614 APN: -----------~----------------- Type of Project & Use: UJW\IMONCA.o-..Q_Net Project Density: ~ DU/AC Zo~in : C -2:-: General Plan: (: _, Facilities Management Zone: Le CF m/ ut) #--4--Date of participation: :7/0\/ Remaining net dev acres: Of 1r One ~ --r-- (For non-residential developm,ent: Type of land used created by th is perm it: C6):Yl.\l}\o,r"c,<..M ) Legend: cg] Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES NO TYPE ___ _ DATE OF COMPLETION: -------- Comp Ii an c e with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE ---- APPROVAL/RESO. NO. _____ DATE ___ _ PROJECT NO. _______ _ OTHER RELATED CASES:---------~--------- Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ________________________ _ Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NoL, CA Coastal Commission Authority? YES NO~ If California Coastal Commission Authority: Contact them at -3111 200. San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Camino Del Rio North, Suite Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determiriation Log as needed. H:\ADMIN\CDUNTER\BldgPlnchkRevChklst ~□□ ,ef □□ CI(o □ (□□ Q1J □ ~□ □ ~□ □ lnclusionary Housing Fee required: YES NO X (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES __ NO~ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1. Setbacks: Front: Required ______ _ Shown -------Interior Side: Required ______ _ Shown -------Street Side: Required ______ _ Shown -------Rear: Required ______ _ Shown ------- 2. Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown 3. Lot Coverage: Required Shown 4. Height: Required Shown ~ D D 5. Parking: Spaces Required ______ _ Shown ------- Guest Spaces Required ______ _ Shown ______ _ @" D D Additional Comments ______________________ _ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER~&._ DATE otf2//6-a- H:1AoMIN1couNTER1BIdgPInchkRevchklst Carlsbad Fire Department 021037 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan Reviewed by: Date of Report: _04_1_17_1_20_0_2 _______ _ Name: Bob Laser Address: 4909 Murphy Canyon Rd. City, State: San Diego CA 92123 Plan Checker: Job#: 021037 Job Name: Sprint Bldg#: CB021037 ----------------~~ Job Address: 1957 La Costa Avenue Ste. or Bldg. No. 1:8] Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and/ or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 021037 2nd FD File# 3rd Other Agency ID • VeldciTel·-' April 23, 2002 Project Name: Carlsbad Vons/ SPRINT PCS Project Number: SD40XC307B Project Address: 7710 El Camino Real, Carlsbad, CA92009 Plan Check Engineer: Mr. David Yao Plan Check Number: 02-1037 Plan Check Date: 4/17 /02 STRUCTURAL RESPONSES: 7). Both Wind and Seismic forces were incorporated in the report. See page 7 and page 8 for the derivation of wind load. See page 9 for derivation of seismic force. See page 18 to page 20 for load cases for both wind and seismic forces. Worst case was examined for connection design. 8). Detail 6/S4 revised. 9). Per page 35, continuity plates serve as column web stiffeners. No additional stiffeners ore required. 10). See calculation page 48 AND 49 2ND FL joist revised to 2x12, 3•d and 4th lever revised to 2x10 Please be advised that the framing plan has been rotated 90 degree. However, all dimensions remain unchanged. Sincerely submitted, Chris Lee Project Engineer, 18071 Fitch Avenue, Irvine, CA 92614 USA T: 949.809.4999 F: 949.553.3919 www.velocltel.net \ bruce h. mlddleswart p.e., ltd. structural engineer 4450 n 12"> st. Ste#238. phoenix. arizona 85014 telephone: 1602)-287-8720 fax: 1602)-287-8737 Project Name: CARSBAD VONS Job Number: 02039 DESIGN CRITERIA Code Compliance with the 1997 Uniform Building Code with City in Authority Amendments. Wind Loads P = Ce·Cq·q8·1 = I. 31*1.4*12.6*1.0=23.I psf Exposure C, Basic wind speed 70 mph Ce= Cq = I = Walls Exposure C -40 ft .......................... 1.31 (Projected area method , minor structure any direction) I. 4 Basic wind speed 70mph.. ... ....... .... .... ..... 12.6 Standard occupancy 1.00 Dead Loads psf 1/4" FRP ................................................................................................ 2.0 Total Dead Load 2.0 Material Strengths FRP [LAY-UP] PSI Fb ............................................................................................ 20000 E ............................................................................................ 1500,000 FRP [ HONEYCOMB CORE] Fb ............................................................................................. 4500 E {BYTEST]. ............................................................................ 253,000 VERSALAM Fb ............................................................................................. 2496 E .............................................................................................. 2,000,000 Job# 02039 03/22/2002 PageD 1 LENTECH design criteria.doc/REV 7-% ......... -1 --1·--'--....... _, 1 . --, f ' • -. . prup 1 ~ h~ 11:l~q~l,~swart p.e., ltd. -... -i ,~:-,tr1,1~tvrQ!-englneer 1110 ~-f11issourl, suite 400, phoenix,az 85014 · , (602) 287-8720 fax (602) 287-8737 '. . . -· -~ . . -· .. . sh!. · / ·Of / ' job rio.-GI~~ ~ . -~ //. ,_. ~ "' . . date :i. ✓,.,,, , •. i : •.. · .. -. . .:c~ ~ kli2d:. -~ ... MI/ ,,,Jl:I ~,¥ / .-v' JC'/~(. " N/Al.;:/IJ w ~ f"' ~~S _ ~f <2 3,b '.,c, A,~.L. C, ·--r . FA411' s ;:,,,;; a.. -·-·•--···-··-~-. }J ,$/ j ½z ' ;27 /.Se' t>l l J, "'1st 3 6 , o3,., ~/4. ,!21' 7><-'23./ <i !23 -ti. (2.o,J,i6'q' c,v/ 1/4)< 4,4 u,.::. .. e.. /~ /I ,;??14-~ Gi/c:::.. €,dp/l<T /lf:FN-~ /t., 7fJrA'-. .::zo :z!l-/4.,, c,1~ ~ /J./f,t',