Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1959 PALOMAR OAKS WAY; 300; CBC2018-0377; Permit
Job Address: 1959 Palomar Oaks Way, 300 Permit Type: BLDG-Commercial Work Class: Tenant Improvement Parcel No: 2130922600 Lot U: Valuation: $727,834.99 Reference U: - Occupancy Group: Construction Type: U Dwelling Units: Bedrooms: Project Title: Description: Applicant: MARISSA CLOW Bathrooms: Orig. Plan Check U: Plan Check U: LABYRINTH: 15,649 SF T.I. OFFICE TO OFFICE Owner: 1959 PALOMAR OAKS LP Jiity of Carlsbad. Commercial Permit Print Date: 02/12/2019 Permit No: CBC2018-0377 Status: Closed - Finaled Applied: 07/13/2018 Issued: 09/28/2018 Permit Finaled: Inspector: TFraz Final Inspection: 2/12/2019 8:33:54AM Contractor: PACIFIC BUILDING GROUP 1959 Palomar Oaks Way, 200 9752 Aspen Creek Ct, Ste 100 CARLSBAD, CA 92011 SAN DIEGO, CA 92126 858-652-5088 * BUILDING PERMIT FEE ($2000+) $2,721.00 BUILDING PLAN CHECK FEE (BLDG) $1,904.70 ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL . $242.00 GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION $170.00 MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL $104.00 5B1473 GREEN BUILDING STATE STANDARDS FEE $30.00 STRONG MOTION-COMMERCIAL - $203.79 Total Fees: $5,375.49 Total Payments To Date: $5,375.49 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 1 760-602-2700 1 760-602-8560 f I www.carlsbadca.gov (c i ty of Carlsbad COMMERCIAL BUILDING PERMIT APPLICATION B-2 Plan CheckC203 77 Est. Value PC Deposit Date (._!1- tc5 Job Address Iq S61 Pc'lor,,üy- I2Kc (AJ'Vj Suite: 3O0 APN: ? 1 3o i.2 z Coo Tenant Name: La. jrvsik CT/Project#:CI3C °I' -0377 Lot #: FireSprinklers: no Air Conditioning: (j'i no BRIEF DESCRIPTION OF WORK: lfrtv 1'9rl)LIe4'r12# I- QF06h-,q ')Ct_ - -Sle. ec.ir s occctp cuq 000V—. F-1 Addition/New: New SF and Use, New SF and Use, Deck SF, Patio Cover SF (not including flatwork) XTenant Improvement: 15,V11 SF, Existing Use Côr'ert1c( Proposed Use COfrr- SF, Existing Use Proposed Use J Pool/Spa: SF Additional Gas or Electrical Features? U Solar: KW, Modules, Mounted, Tilt: Yes / No, RMA: Yes / No, Panel Upgrade: Yes / No LI Plumbing/Mechanical/Electrical Only: LII Other: APPLICANT (PRIMARY) Name: es- Gvw' -iaA CIOL) Address: Io Ir C-Je PkP '30 City: Sckt, Nez,_State:C.k Zip: q(c: Phone: (c,iq -':3sôo Email: y.iQ465 3s -e.cov-s DESIGN PROFESSIONAL Name: cc Gv,4, —1610Y4S5k C4th Address: 1(i(00 14&-e C~ircLe r.tor'1- 433' City: State:CA Zip: Phone: Email:vi-orks. (- Architect State License: PROPERTY OWNER Name: L46jvw1's.- - 9ceU lArcJ— Address: 170T Avfvv% A•U+149 S.5k 230 City: -i6c..d State:' Zip: 12 00<K Phone: (9c) - Email: CONTRACTOR BUSINESS Name: (3i C nscHc-., •. Ty- Iic Address: Qs W1 &Ak2A1 City: (r-('cbc( State:cIA Zip: I'O01 Phone: (16&) q(-lr30 Email: +'r-ays ikftCc l-)v6('1C. Cc) State License:lC)SG, Bus. License: )3LNK0031 - O — O'7 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-2 Page 1 of 2 Rev. 06/18 (OPTION A): WORKERS'COMPENSATION DECLARATION: / hearby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. XIhave and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: LV. -ec4 Vifi o- c ( I t.i.'y Ctr#ira Policy No. 7'6000 JLjj S('( Expiration Date: ____________ 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come tv subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, interest and attorney's fees. ' 1 CONTRACTOR SIGNATURE: 'l _7,1.n _l_—'_(_--.'_-_- AGENT DATE: (OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Low for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). o I am exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes 0 No I (have / have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): OWNER SIGNATURE: LIAGENT DATE: CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: Lender's Address: ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prei,ention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? C3 Yes 0 No - . IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5,0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at anytime after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: l4i.jj,-.,-- DATE: q77 f 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-2 Page 2 of 2 Rev. 06/18 Permit Type: BLDG-Commercial Application Date: 07/13/2018 Owner: 1959 PALOMAR OAKS LP Work Class: Tenant Improvement Issue Date: 09/28/2018 Subdivision: CARLSBAD TCT#80-38 Status: Closed - Finaled Expiration Date: 08/05/2019 Address: 1959 Palomar Oaks Way, 300 Carlsbad, CA 92011-1310 IVR Number: 12522 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical - Yes BLDG-44 Yes Rough-Ducts-Dampers 02/06/2019 02/06/2019 BLDG-85 T-Bar, 083144-2019 Passed Tim Frazee Ceiling Grids, Overhead Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 1. BLDG-14 . , Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Top out Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes S Rough-Ducts-Dampers 02/12/2019 02/12/2019 BLDG-Final 083663-2019 Passed Tim Frazee Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Ys BLDG-Plumbing Final Yes BLDG-Mechanical Final - - Yes BLDG-Structural Final . S Yes BLDG-Electrical Final , Yes BLDG-Fire Final 083212-2019 Scheduled Dominic Fier! Checklist Item COMMENTS - Passed FIRE- Building Final - . No Complete CompleteComplete Incomplete February 12, 2019 - Page 2of2 Permit Type: BLDG-Commercial Application Date: 07/13/2018 Owner: 1959 PALOMAR OAKS LP Work Class: Tenant Improvement Issue Date: 09/28/2018 Subdivision: CARLSBAD TCT#80-38 Status: Closed - Firialed Expiration Date: 08/05/2019 Address: 1959 Palomar Oaks Way, 300 Carlsbad, CA 92011-1310 IVR Number: 12522 Scheduled Actual Inspection Type Inspection No. inspection Status Primary Inspector Reinspection Complete Date Start Date 1110712018 I' 11/07/2018 BLDG-84 Rough 075432.2018 Partial Pass Tim Frazee Reinspection Incomplete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) - BLDG-24 Rough-Topout - Yes BLDG-34 Rough Electrical . Yes BLDG-44 Not done yet 11/07/18 No Rough-Ducts-Dampers - 11/09/2018 11/09/2018 BLDG-44 075673-2018 . Partial Pass Tim Frazee . Reinspection Incomplete Rough/Ducts/Dampe . rs - - Checklist Item COMMENTS . . Passed BLDG-Building Deficiency Pookie on duct work north half of space Yes 11/16/2018 11/16/2018 BLDG-17 Interior 076294.2018 Cancelled System Administrator Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency . No 11/19/2018 11/19/2018 BLDG-17 Interior 076381-2018 Passed • Tim Frazee Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency . Yes 12/06/2018 12/06/2018 BLDG-44 078106-2018 Partial Pass - Tim Frazee Reinspection Incomplete Rough/Ducts/Dampe rs Checklist Item COMMENTS Passed BLDG-Building Deficiency Pookie on duct work north half of space Yes - Pookie the remainder except units in 3 Rms see card 12/10/2018 12/10/2018 BLDG-44 078295-2018 Rough/Ducts/Dampe rs Checklist Item BLDG-Building Deficiency 01/14/2019 01/14/2019 BLDG-85 T-Bar, 081178.2019 Ceiling Grids, Overhead Passed Tim Frazee COMMENTS Pookie on duct work north half of space Pookie the remainder except units in 3 Rms see card Pookie on remaining units (3) OK Passed Tim Frazee Complete Passed Yes Complete February 12, 2019 - Page 1 of 2 I'3W1 rf5Ji( 5 cay 11:5410 TØ VOl ,\ 4 \/ CITy O 13611ding Division LSD INSPECT ION REV EINSPECTION RECORD CARP WIIhAPPR OVED PLANS MUST BE KEPT ON THEKB ¶ t.CALL BEFORE A&RAdFOR IEk1ORK DAY INSPI 'FOR BUILDING INSPECTION . 760-60227 OR GO TO: ça.çoyf,g AND CLICI4 Request Inspection" DATE: YES" is checked below that Di%zjsb,,!. 3PPrOvil is requiree, 760-602-8560, email to blder 7 7ECO RD COPY 1CBC2018-037i I RD' #300 1959 PALOMAR OAKS WAY / BYRINTH 1569SF LI; OFFICE TO OFFICE V 4 2130922600 8/612018 cBC2oi8-0377 NO IF MARKED 17 t- REQUIRED PRIOR TO ANY CONSTRUCTION Date I Inspector - STORM WATER PRECOPi TtPJ-3REOUIREO 760-602-272; Iow 24 hours IF MARKED Ø? IIflrS flflIflY. iii nit..0 FIt.AL •""" Notes SPY OF:ARD O1tJIEE0. - Fire Prevention - -: 76-0;-64 Iow 48 hours 'ij/Ifri 12t1A Planning/Landscape -. 760-9M Mow 48 hours Li CM&I IEngIneertng PVCthrI3 760.438.3891 C.II before 2 pm ype oi inspection V. - -' Tvoe of Inspection iI_i1JI.Jli #-i FOUNDATiON #31 Date Inspector Date ' Inspector DELECTRICUNDERGROUND OUFER #2 REINFORCED STEEL #34 RUUGH ELECTRIC / EV CHARIER I jmm #16 MASONRY PREGROUT - #33 C EI.EC SERVICE #320TEIIPORARY. 0 GROUT DWALLDRAJNS #35 PIOTOVOLTAIC I #:O T1LTPANELS. - #38 SONS I #1 POUR STRIPS = :- SLOG- BNAL #1- COLUMN FOOTINGS i ; Date lflsQector #41 (E1DERGROUND DUCTS &PI'ING #14 SUSFRAME OFLOOR OCEILING #15 ROOFSHEATHING #44 bUCT&PLENUM DRE.PIPING. (2_1 to he' #E EXT. SHEAR PANELS- -. #43 HEAT-AIR COND. SYSTEMS g- #t INSULATION - BLDG-INAL I H #13 EXTERIOR LATH Date Inector #81 I NDERGROUND (11,12,21,) #Ü INTERIOR LAT(DRYWA jI 1 BLDG-FINAL - - - #82 IRYWALL,LXI LATH, GAS 1S(17,l8,23) COME 9 PLUMBING Date Inspector - 483 LOOFSHEATING,EXISHEAR(13,15)- #2k! 0 SEWER & BL/CO 0 pt/co #84 FRAME ROUGH COMBO (14.24,34,44: Th #2: UNDERGROUND OWASTE IJWill _________ #85 T-B8r14,24,34,44 #2& TOP OUT 0 WASTE 0 wm - - BLDGIINAL OCCUPANCY #27 TUB&$HOWERPAN - _________ I1 Date Inspector #22 0 GAS TEST 0 GAS PIPING - A/S UNDERGROUND VISUAL N \ \\ \ #22 WATER HEATER A/S UNDERGROUND HYDRO #2E SOLAR WATER A/S UNDERGROUND FLUSH BLDKI-FINAL A/S (IJERHEAI) VISUAl. - #51 irOoLE(CAV/STEEL Date Inspector A/S (RIERHEAD HYDROSTATIC i_ ________ A/SRNAI. #52 PLUMBING #53 EEC/CONDWT).VWIRING #54EQU1POTENVnALBOND #55 PA .SAlFENCE/AL#8MS #51 ouitrir : : ________ __________ ___________ _________ F/AUGH-IN - f/AANAL flXEILXTINGUISHINGSYSTEM1lOUGH-IN FIXED EXTINOSYSTEM HYDROAT1CTESI FIXED EXTINGUISHING SYSTEM FINAL MEDCAL GAS PRESSURE TEST MEDsCALGAS FINAL REY06j V V V SEt BACK iC#SPfCSAL NOTES EsGil A SAFEbuUtConipany DATE: September 20, 2018 APPLICANT -i -iU RI S. JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0377 SET: III PROJECT ADDRESS: 1959 Palomar Oaks Way, #300 PROJECT NAME: Labyrinth TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. Lii The check list transmitted herewith is for your information. The plans are being held at, EsGil until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: . Telephone #: Date contacted: (YN ) Email: Mail Telephone Fax In Person REMARKS The:loose: atthé :ôity.. By: Kurt Culver Enclosures: EsGil log 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil A SAFEbuiLt Company DATE: September 17, 2018 JURISDICTION: Carlsbad U APPLICANT JURIS. PLAN CHECK #.: CBC2018-0377 SET:!! PROJECT ADDRESS: 1959 Palomar Oaks Way, #300 PROJECT NAME: Labyrinth TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Marissa Clow EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Marissa Clow Telephone #: 619-296-3500 D emtseted : 'It 7 lit (by—. Email: marissa@FSDesignGrp.com JVl all Tele Fax In Person REMARKS: By: Kurt Culver Enclosures: EsGil 9/7/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576 Carlsbad CBC20 18-0377 September 17, 2018 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. GENERAL Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS Please demonstrate that the sliding doors will usable by the disabled when they are in the fully open position. PLEASE PROVIDE MANUFACTURER'S CUT SHEETS, SHOWING THAT THE DOORS CAN BE CLOSED BY PERSONS WITH DISABILITIES (SEE CBC SECTION IIB-404.2.7). ADDITIONAL 13: Please see the following sheet for MEP corrections. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. ,Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes 0 No Carlsbad CBC2018-0377 September 17, 2018 The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at Esgil. Thank you. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) Please provide manufacturer's installation instructions for supports and. engineer review if the heat pump units are to be suspended within the third floor. WITHIN THE CALCULATIONS YOU PROVIDED, THERE ARE A NUMBER OF STRUCTURAL DETAILS. THOSE DETAILS MUST BE ON THE PLANS (THE BUILDING INSPECTOR SHOULD NOT BE REQUIRED TO THUMB THROUGH STRUCTURAL CALCULATIONS TO FIND NECESSARY DETAILING). $ EsGil A SAFEbuUt'Cornpny DATE: July 25, 2018 JURISDICTION: Carlsbad U APPLICANT ,zr PLAN CHECK #.: CBC2018-0377 SET: I PROJECT ADDRESS: 1959 Palomar Oaks Way, #300 PROJECT NAME: Labyrinth TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should, be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at EsGil until corrected plans are submitted for recheck. Lii The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Marissa Clow EsGil staff did not advise the applicant that the plan check has been completed. EsGil staff did advise the applicant that the plan check has been completed. Person contacted: Marissa Clow Telephone #: 619-296-3500 7l2GIl8' (by-4 Email: marissaFSDesignGrp.com all Telephone F x In Person REMARKS: By: Kurt Culver Enclosures: EsGil 7/16/18 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad CBC20 18-0377 July 25, 2018 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK #.: CBC2018-0377 JURISDICTION: Carlsbad OCCUPANCY: B USE: Office TYPE OF CONSTRUCTION: V-B ACTUAL AREA: 15,649 ALLOWABLE FLOOR AREA: OK STORIES: 3 HEIGHT: n/c SPRINKLERS?: Yes OCCUPANT LOAD: -156 DATE PLANS RECEIVED BY JURISDICTION: 7/13/18 DATE INITIAL PLAN REVIEW COMPLETED: July 25, 2018 FOREWORD (PLEASE READ): DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/16/18 PLAN REVIEWER: Kurt Culver This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2016 CBC, Which adopts the 2015 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2015 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad CBC20 18-0377 July 25, 2018 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK #.: CBC2018-0377 PREPARED BY: Kurt Culver DATE: July 25, 2018 BUILDING ADDRESS: 1959 Palomar Oaks Way, #300 BUILDING OCCUPANCY: B BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 727,835 Air Conditioning Fire Sprinklers TOTAL VALUE 727,835 Jurisdiction Code 1cb jBy Ordinance 1997 UBC Building Permit Fee IV( 1997 UBC Plan Check Fee V Type of Review: ED Complete Review 0 Structural Only E Repetitive Fee Repeats 0 Other El Hourly Hr. @ * EsGII Fee $1,659.97 Comments: Sheet of 1 Carlsbad CBC20 18-0377 July 25, 2018 GENERAL Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire Departments. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil is complete. PLANS 2. Each sheet of the plans must be signed by the person responsible for their preparation. California State Law. Please demonstrate that the sliding doors will usable by the disabled when they are in the fully open position. NON-RESIDENTIAL GREEN BUILDING STANDARDS (Additions and Alterations) The California Building Standards Commission (BSC) has adopted the Green Building Standards Code and must be enforced by the local building official. The Green Building Standards apply to nonresidential additions or tenant improvements throughout California. These standards apply to nonresidential additions of 1,000 sq. ft. or larger or alterations (tenant improvements) with a value of $200,000 or more. CGC Section 301.3. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Waste management. Note on the plans that the contractor must submit to the Engineering Department or other Agency that regulates construction waste management a Waste Management Plan that outlines the item listed in CGC Section 5.408.1.1. 2. Recycling. Note on the plans that a minimum of 65% of construction waste is to be recycled and/or salvaged. CGC 5.408.1. Documentation shall be provided to the enforcing agency which demonstrates compliance. CGC Section 5.408.1.4. - Carlsbad CBC2018-0377 July 25, 2018 Recycling. Note on the plans that an identified, readily accessible area shall be provided that serves the entire building for collecting recycling, such as paper, cardboard, glass, plastics, metals, etc. CGC Section 5.410.1. Documentation. Note on the plans that a building "Systems Manual" as listed in CGC Section 5.410.2.5 shall be delivered to the building owner or representative and the facilities operator. Further, note on the plans that the "Systems Manual" shall contain the required features listed in CGC Section 5.410.2.5.1. Pollutant control. Note on the plans that during construction, ends of duct openings are to be sealed,,and mechanical equipment is to be covered. CGC 5.504.3. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 5.504.4 and Tables 4.504.1, 5.504.4.1 5.504.4.2, 5.504.4.3 and 5.504.4.5 for: Adhesives, Sealants, Paints and Coatings, Carpet and Composition Wood Products. CGC 5.504.4. Pollutant control. Note on the plans that mechanically ventilated buildings shall provide regularly occupied areas with air filtration media for outside and return air that provides at least a Minimum Efficiency Reporting Value (MERV) of 8. MERV 8 filters shall be installed prior to occupancy. CGC Section 5.504.5.3. Pollutant control. Note on the plans that where outdoor areas are provided for smoking, such areas are prohibited within 25' of building entries, windows and outdoor air intakes. Signage shall be posted to inform occupants of the prohibitions. CGC Section 5.504.7. Environmental comfort. Note on the plans that wall and floor assemblies separating tenant spaces (and tenant spaces from public spaces) shall have an SIC of at least 40. CGC Section 5.507.4.3. Environmental comfort. Wall and roof assemblies exposed to noise sources shall have an SIC rating of at least 50, with exterior windows having a minimum SIC of 40 in the following locations, per CGC Section 5.507.4.1: Within the 65 CNEL noise contour of a freeway, railroad or industrial source, as determined by the jurisdiction's Noise Element of the General Plan. ' Within the 65 CNEL noise contour of an airport. Note on, the plans whether ornot this addition or -tenant improvement is located within the area§ listed above. Carlébad CBC20 18-0377 July 25, 2018 11. Water reduction. Show on the plans the following maximum fixture flow rates from the table below. Revise general notes, plumbing plans, etc. to match. CGC 5.303. MAXIMUM FIXTURE FLOW RATES FIXTURE TYPE MAXIMUM FLOW RATE Water closets 1.28 gallons/flush Urinals (wall mounted) 0.125 gallons/flush Urinals (floor mounted) 0.5 gallons/flush Showerheads 2 gpm © 80 psi Lavatory faucets- nonresidential 0.5 gpm @60 psi Kitchen faucets 1.8 gpm @ 60 psi Metering faucets 0.2 gallons/cycle Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. ADDITIONAL Please see the following sheet for MEP corrections. To speed up the review process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: U Yes U No The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at Esgil. Thank you. Carlsbad CBC2018-0377 July 25, 2018 PLUMBING, MECHANICAL, ELECTRICAL, and ENERGY COMMENTS The PLUMBING, ELECTRICAL, AND ENERGY are fine as submitted. MECHANICAL (2016 CALIFORNIA MECHANICAL CODE) Please provide manufacturer's installation instructions for supports and engineer review if the heat pump units are to be suspended within the third floor. Provide on mechanical plans means for outside air to the inside heat pump units. Note: If you have any questions regarding this Electrical, Plumbing, Mechanical, and Energy plan review list please contact Eric Jensen at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. -• PSI PSI RECEIVED - STRUCTURAL CALCULATIONS PROJECT: LA jiJ 7•4• fr1fL C4'-'iTJ DESIGN ASSUMPTIONS: CONCRETE STRENGTH AT TWENTY EIGHT DAYS: MASONRY: GRADE "N" CONCRETE BLOCK F' M: .MORTAR: TYPE S 1,800 PSI GROUT: 2000 PSI REINFORCING STEEL: A-615 GRADE 40: #4 AND LESS (U.O.N.) GRADE 60: #5 AND LARGER c 'SEP 04 2018 CITY OF CARLSBAD BUILDING DIVISION /J1HTK STRUCTURAL ENGINEERS, LU' ESS1 R Ku 31 STRUCTURAL STEEL: A-36 LUMBER: DOUGLAS FIR-LARCH JOISTS BEAMS AND POSTS STUDS SEISMIC FORCE. WIND FORCE: DESIGN LOADS: #2 #2 STUD OR BETTER REPORT NO.: - SOIL PRESSURE:— ROOF DEAD LOAD FLOOR DEAD LOAD ' WALL DEAD LOAD SLOPiNG f!I INT. ' ROOFING FLOORING ' INTERIOR 10 PSF PLYWOOD PLYWOOD ' EXTERIOR 16 PSF JOISTS JOISTS 7 INSUL. & CLG. INSUL & CIG. MISC. MISC. TOTAL = L(i TOTAL ROOF LIVE LOAD FLOOR LIVEZOAD SLOPING = / INTERIOR 40 PSF FLAT ' BALCONY 60 'PSF (U.O.N.) EXIT WALKWAY 100 PSF These calculations are limited only to the items included herein, selec t e d b y t h e c l i e n t a n d d o n o t i m p l y a p p r o v a l o f a n y other portion of the structure by this office. These calculations are not valid i f a l t e r e d i n a n y w a y , o r n o t a c c o m p a n i e d b y a wet stamp and signature of the Engineer of Record. ' • Job No. Designed By • j Date ( FO* ) 5an Diego (896 67 9 89 14288 DanIelson Street, Suite 8 209. Poway, CA 92064, (858) 679) .-.1 cçit, 3(l~c4tJ O F tc"5 •(2cjt - / /,~ ? ,v7'P1 7 r 21 L I r'J ( 7 'A - UNIST/ I2cwo L ON L-A (N )Zxk (2-4 t\J y. 1f 2-dX+s ) t 19