HomeMy WebLinkAbout1969 Kellogg Ave; ; CBC2018-0467; Permit(city of
Carlsbad
Commercial Permit
Print Date: 01/10/2019 Permit No: CBC2018-0467
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
1969 Kellogg Ave
BLDG-Commercial
2120921200
$275,000.00
M
Work Class: Tenant Improvement
Lot#:
Reference#:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Description: KELLOGG FLOWER MARKET, WAREHOUSE WHOLESALE, PRODUCTION & OISTRUBUTION
Applicant:
RICHARD LUND
2033 San Elijo Ave
Cardiff by the Sea, CA 92007-1726
619-920-2134
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLOG)
Owner:
TECHPLEX LP
1000 Pioneer Way
EL CAJON, CA 92020
ELECTRICAL BLOG COMMERCIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLOG COMMERCIAL NEW/ADDITION/REMODEL
581473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $2,522.33 Total Payments To Date: $2,522.33
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Closed -Finaled
08/15/2018
09/25/2018
AKrog
1/10/2019 ll:49:37AM
$0.00
$1,247.25
$873.08
$89.00
$170.00
$55.00
$11.00
$77.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
(
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: []PLANNING []ENGINEERING ;_-:-JBUILDING [_jFIRE i.JHEALTH ['JHAZMATIAPCD
{"city of
Carlsbad
Bulldlng Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
Plan Check No.l.BC... Z I!'\ 8 • O'i '-1
Est. Value ~ ~
Plan Ck. Deposit
www .carlsbadca.gov Date
JOB ADDRESS ACE /U f '" 212 092 12 00 " . CONS • TYPE OCC. G OU"
1118 M
DESCRIPTION OF WORK: Include Square FNt at Affected Area(•)
Proposed Use: Wholesale Flowers (Cooler Warehouse, Warehouse Wholesale, Product Distribution)
Municiple Code: PM Planned Industrial Zone, Title 21 Zoning, Ch. 21.34, 21.34.020 Permitted Uses
-z. 4-( s--i;-Tf7 TY
EXISTING USE PROPOSED USE GARAGE {SF) PATIOS (SF)
Product Production 'roduct Wholesai<
APPLICANT NAME
Primary Co11tact Richard Lund, Grupo Pacific
ADDRESS 2033 San Elijo Ave, 120
CITY STATE ZIP
Cardiff CA 92007
PHONE FAX
619 920 2134 NA
EMAIL lundgrupopacific@gmail.com
DESIGN PROFESSIONAL Grupo Pacific
ADDRESS 2033 San Elio Ave, 120
CITY STATE ZIP
Cardiff CA 92007
PHONE FAX
619 920 2134 NA
EMAIL
lundgrupopacific@gmail.com
STA.TE LIC.11
WORKERS' COMPENSATION
Workeh' Compenutlon DecleraUon: I hereby affirm under penally of perjury one of the following declarations:
0 I have and wHI maintain a Cll'llflcaltl of consent to Mlf-lnaure for workers' compensabon as provided by Section 3700 ol !he Labor Code, !or the performance of tile work for which thJs permit is illsued. D I have and wlll maintain W0111e11' comi,enntlon, as reou!red bv Section 3700 of the Labor Code, for the performance of the work forwhld'I tt,js permH Is Issued. My workers' compensation !Msmance carrlBI' and policy
numbBl"al'9: Insurance Co. __________________ Polley No. ____________ Expiration Date ________ _
This section need not be completed If the permit Is for one hufldred dollars (S100) Of less. 0 Clrtlftcate of Exemption: I certify that in the performance of the work !or which this permit is issued, I shal not employ any peraon in any manner so as to become subject to the Workers' Compensation Laws of
Califomia, WARNING: hllul'I to HCUl'9 worilerl' compenutlon GOVtrllll 11 uni• ~ and 1h1II subjec:t an emptayer lo cri ilu and clvll fines up loons hundred thousand d0Har1 (&100,000), In
ded~ectlon370 _r,~1,lntenm1ndattomey'1 ~NT
I herelJy llffllm 1/lal I 1m sxsmpt from Contractor's l.iceflse Law for Ille fo/lollllng re1S011: D 1, as owner of the property or my employees l'.ith wages es their sole oompensalkm. wlH do the work and the structure is riot intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors
License Law does not apply to an owner of proparty wno builds or lmpl'O'leS thereon. and l'fflO does sucti work himself or th!Ollgh his own employees, provided that 11.1ch Improvement& are not intended or offered for
sale. If, however, the bulld,\>ig or lmprowiment Is sold within cne ye.ir of compkition, the ownar41ulk!er wlN have the burden ofpruvlng that he did not build or Improve forlhe purpose of sale)
□
□
I, as owner olthe property, am exclu~vely contracting with icensad contractor! to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such proiects with cootractor(s) icensed pur!uant to the contractor's License Law).
I am exempt under Seciion ____ ,Business and Professions Code for this reason:
1. I peraonalty pliln to provide !ti& major labor and matenals fol eonstT\lclion of the proposed propen'j improvement. 0Yes 0No
2.1 (have I have not) signed an application for a build Ing permit for the proposed work,
3.1 hl'le conlr!lctedwith the following person (firm) to provide Iha proposed constructior, (lntlld& name addl"8SII I phone/ contractors' Dcense number):
4.1 plan to provide portions ct the work, but\ have hired the lollowlng person to roordlnate, supl!IVlse and provide the major worl< (inckide name I addreS!i I phone I contractors· llcensa number):
5. I wll pro',108 some of the wortc. but J havti contracled (hired) the following person~de Iha work indicated (In e name I address / phone / type ol work): ,,
,,6$ PROPERTY OWNER SIGNATURE
COMPL6:TE THIS SECTION FOU NON-RESIDENTIAL BUILDtNG PERMITS ONLY
ls lhe applicant or future bulk!lng occupant required to submK a busjness plan, acutely hazardous materials registrabon form or risk mBMaij81Tle11I and prawntion program under Sections 25505, 25533 ix 25534 of the
Presley-Tanner Hazardous SuDStance Act.ount Ad? □ Yes □ No Is lhe applicant orfutunt DUiiJlng occupant required to obltlln a permit from the air pollution control district or air quilllty management district? □ Yes □ No
ls the facility to be constructed -Mlhin 1,000feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONS1"RUCTION LENDING AGENCY
I hereby afflnn that there 1s e constructioo lendlng agency for the perfonnance of the work this permit 1s !ssued (Sec 3097 (1) CIVIi Code)
Lender's Name lender's Address
A PP LI C·A NT CE RTI.F IC A tl.O N
I certify that I have read the application and stBtatbatthe above lnfonnatlon Is correc:t and ttiatthe llionnation on the plans II 8CGJrate. t a,eeto complylMlh all City ordinances and Sblte laws relating to bulldlllgCGMtruetlon.
l hereby aulhooze ~ of the City rJ Carlsbad to enter UJ))l the above mentioned property for lmpedial l)'dpOSeS. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSSAD
AGAINST All LIABL!TIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN /1Jo4YWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRl>NTING OF THIS PERMIT.
OSHA: AA OSHA permit is requifed for excavalions over S'0' deep and demollion or ocnslJuction r:J strudUreS over 3 stories in heigll.
EXPIRATION: Ewry permit issued by the Building Official under Iha JJ'OVISIOlls d lhls Code shal eiqire by ~d becana nuU and '.oo if the bufding or wcrk authorized by such permit is not c:orrrnenced \Whrt
180 days frool lhe date of sudl permit or if lhe build or work authorized b such permit is or ~odcned at anytme after the is commenced for a pefiod a 180 days (Sectk>n 106.4.4 tklHorm 81.Jildrtg Code).
/ ./ _,,/ ,·'
,..:5 APPLICANTS SIGNATURE ~ .• ,, , DATE C::, S::
, PERMIT INSPECTION HISTORY REPORT (CBC2018-0467)
" ''
Pcnrnt Typ0.·
Work Class:
Statu'.>
Scheduled
Date
12/26/2018
01107/2019
01/10/2019
BLDG-Commercial Application Date: 08/15/2018 Owner:
Tenant Improvement Issue Date: 09/25/2018 Subdivision:
Closed -Finaled Expiration Date; 07/08/2019 Address·
IVR Number: 13240
Actual
Start Date Inspection Type Inspection No.
12126/2018
01/07/2019
01/10/2019
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
BLDG-Fire Final 078358-2018
Checklist Item
FIRE-Building Final
BLDG-34 Rough 079841-2018
Electrical
Checklist Item
BLDG-Building Deficiency
BLDG-Final 080603-2019
Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
BLDG-Final 081005-2019
Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Inspection Status Primary Inspector
COMMENTS
Failed Dominic Flerl
COMMENTS
The address for this facility is 1960 Kellogg.
Riser and alarm room door needs to be
labeled. Fire year cert for sprinkler system
required
Partial Pass Andy Krogh
COMMENTS
Cooler rooms and exterior condenser units
Partial Pass Andy Krogh
COMMENTS
Temp occupancy ok
Insulation copper pipe at duct
Head strip at ada parking stalls
Gfci protection required in women's
restroom, label instahot disconnects
Passed Andy Krogh
COMMENTS
Temp occupancy ok
January 10, 2019
TECHPLEX LP
CARLSBAD TCT#81-46 UNJT#02
1969 Kellogg Ave
Carlsbad, CA 92008-6582
Reinspection
Passed
No
No
No
No
No
Re inspection
Passed
No
Re inspection
Passed
Yes
Reinspection
Passed
Yes
No
Yes
No
No
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Incomplete
Incomplete
Complete
Page2of2
. P~RMIT INSPECTION HISTORY REPORT<CBC2018-0467)
Prmnit Type: BLDG-Commercial Application Date: 08/1512018 Owner: TECHPLEX LP
Work Class. Tenant Improvement lssuo Dato: 09/25/2018 Subdivision: CARLSBAD TCT#81-46 UNIT#02
Sti:ltus: Closed -Finaled Expiration Date: 07/08/2019 Address: 1969 Kellogg Ave
Carlsbad. CA 92008-6582
IVR Number: 13240
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
10105(2018 10/05/2018 BLDG-14 072180-2018 Partial Pass Paul Burnette Reinspectlon Incomplete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
10/15/2018 10/15(2018 BLDG-21 072990-2018 Passed Chris Renfro Complete
Underground/Underf
Joor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Inspected underground waste for mop sinks Yes
and handwashing sink. OK to backfill
11(01(2018 11,01(2018 BLDG-14 074873-2018 Failed Andy Krogh Reinspection Complete
Frame/SteelfBoltlngf
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Missing screws in cs-16 straps and all top No
tracks missing screws on one side, some
screws missing at window openings
BLDG-24 074989-2018 Partial Pass Andy Krogh Relnspection Incomplete
RoughfTopout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial topout to top of low walls including Yes
water psi test
11/05/2018 11/0512018 BLDG-14 075178-2018 Passed Andy Krogh Complete
Frame/Steel/Bolting/
Welding (Decks)
11/09(2018 11/09/2018 BLDG-11 075749-2018 Passed Andy Krogh Complete
Foundatlon/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Cmu block wall footing ok, pending pictures Yes
of additional vertical bars
BLDG-17 Interior 075750-2018 Passed Andy Krogh Complete
Lath/Drywall
12/1912018 12/19(2018 BLDG-11 079325-2018 Partial Pass Paul Burnette Reinspection Incomplete
Foundatlon/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency No
12/24/2018 12/24(2018 BLOG-Final 079759-2018 Falled Paul Burnette Reinspection Complete
Inspection
----·-··---·
January 10, 2019 Page 1 of 2
DATE: 9/20/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-0467
✓• EsG1I
A SAFEbuilt Company
SET: II
PROJECT ADDRESS: 1969 Kellogg Ave.
PROJECT NAME: Kellogg Flower Market T. I.
□ APPLICANT
□ JURIS.
(g] The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
(g] EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: / . Telephone#:
Date contacted: / (bykl ) Email:
Mail Telephone Fax ln'Verson
0 REMARKS:
By: 9/13/18
EsGil
Enclosures:
8/20/18
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 8/29/2018
JURISDICTION: City of Carlsbad
PLAN CHECK#.: CBC2018-0467
✓• EsG1I
A SAFtb-.;1lt cc,rnp;v,y
SET: I
PROJECT ADDRESS: 1969 Kellogg Ave.
PROJECT NAME: Kellogg Flower Market T. I.
-••W--•~--••••-,•-•'•• ••• -----
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[gi The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[gl The applicant's copy of the check list has been sent to:
Richard Lund
D EsGil staff did not advise the applicant that the plan check has been completed.
[gi EsGil staff did advise the applicant that the plan check has been completed.
□
By: David Yao
EsGil
8/20/18
Telephone#: 619-920-2134
lundgrupopacific@gmail.com
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
City of Carlsbad CBC2018-0467
8/29/2018
-•· ----.... ~-~~-·-----
PLAN REVIEW CORRECTION LIST
MULTI-FAMILY
PLAN CHECK#.: CBC2018-0467
OCCUPANCY: S-1
TYPE OF CONSTRUCTION: IIIB
ALLOWABLE FLOOR AREA: 52500
SPRINKLERS?: Y
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 8/12/18
DATE INITIAL PLAN REVIEW
COMPLETED:8/29/2018
FOREWORD (PLEASE READ):
JURISDICTION: City of Carlsbad
USE: warehouse
ACTUAL AREA: total 34413 T. I. 26525
STORIES: 2
HEIGHT:
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/20/18
PLAN REVIEWER: David Yao
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinance by the Planning Department,
Engineering Department, Fire Department or other departments. Clearance from those
departments may be required prior to the issuance of a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Building Code (Title 24), which adopts the following model codes: 2015 IBC, 2015 UPC, 2015
UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBC2018-0467
8/29/2018
1. Please make all corrections, as requested in the correction list. Submit
FOUR new complete sets of plans for commercial/industrial projects (THREE sets
of plans for residential projects). For expeditious processing, corrected sets can
be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad
Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil is complete.
2. All sheets of the plans and the first sheet of the calculations are required to be
signed by the licensed architect or engineer responsible for the plan preparation.
California State Law.
3. Note on the plans: "All egress doors shall be readily openable from the egress
side without the use of a key or special knowledge or effort." Section 1010.1.9.
In lieu of the above, in a Group B, F, Mor S occupancies (or places of religious
assembly or Group A occupancies having an occupant load of 300 or less), you
may note on the plans "Provide a sign on or near the exit door, reading THIS
DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED." This
signage is only allowed at the main exit. Section 1010.1.9.3. Please clarify why
door F does not have panic hardware?
4.
5.
6.
Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
The first sheet of the structural calculation from MPA should be signed and
sealed by the licensed architect or engineer.
If the water closet compartment has an end-opening door (facing the water closet),
the door shall be located on a diagonal to the water closet, with a maximum stile
width of 4 inches (see the figure below). Additionally, the door must be provided
with a clearance of at least 18" at the strike side, per Section 11 B-404. The floor
plan (A4) and restroom detail on sheet A 10 shows the door is wrong location.
City of Carlsbad CBC2018-0467
8/29/2018
CENTERLINE
OF
FIXTURE
t-2Y
FLUSH
ACTIVATOR
ON WIDE
SIDE
0
32" MIN
TO EDGE
OF WATER CLOSET
4' MAX.
18 32" MIN.
MIN. CLEAR
ACCESSIBLE WATER CLOSET COMPARTMENT
WITHIN A MULTIPLE-ACCOMMODATION TOILET FACILITY
7. Please refer to the following corrections for MPE items.
-------·--·-·---
8. To speed up the review process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
9. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction
list? Please indicate: □ Yes □ No
10. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding
these plan review items, please contact David Yao at Esgil. Thank you.
PLUMBING AND MECHANICAL COMMENTS
City of Carlsbad CBC2018-0467
8/29/2018
PLAN REVIEW NUMBER: cbclS-0467
PLAN REVIEWER: Connor Reuss
SET: I
PLUMBING (2016 CALIFORNIA PLUMBING CODE)
1. Provide complete water line sizing calculations: Include the water pressure,
pressure loss calculations, water demands of all fixtures, and the developed pipe
lengths. CPC 610.0 or Appendix 'A'.
2. Please review proposed sanitary drainage design for the required cleanout
locations. CPC 707.4
Note: If you have any questions regarding this Plumbing and Mechanical plan
review list please contact Connor Reuss at (858) 560-1468. To speed the
review process, note on this list (or a copy) where the corrected items have been
addressed on the plans.
ELECTRICAL, and ENERGY COMMENTS
PLAN REVIEWER: Morteza Beheshti
ELECTRICAL (2016 CALIFORNIA ELECTRICAL CODE)
3. Provide a single line diagram for the new service. Include the following
information:
• Justification of relocated panels AIC rating.
4. For buildings that require two or more exits, emergency illumination is required to
be installed at exterior exit door landings and/or vestibules. Please provide.
CBC 1008.3.2
5. There are two sets of electrical drawings. Please clarify
Note: If you have any questions regarding this Electrical and Energy plan review list
please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note
on this list (or a copy) where the corrected items have been addressed on the plans.
END OF DOCUMENT
City of Carlsbad CBC2018-0467
8/29/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: David Yao
BUILDING ADDRESS: 1969 Kellogg Ave.
BUILDING OCCUPANCY: S-1
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
T.I. 26525
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
------
Bid . Permit Fee b Ordinance • --g ___ -----,_Y ___ _..,.J
Plan Check Fee by Ordinance ------------
Type of Review:
D Repetitive Fee --_·••J Repeats
Comments:
Complete Review
D Other
D Hourly
EsGil Fee
PLAN CHECK#.: CBC2018-0467
DATE: 8/29/2018
Reg. VALUE ($)
Mod.
per city 275,000
275,000
D Structural Only
'------'I Hr. @ • $760.861
Sheet of
civil engineering
structural design
land surveying
STRUCTURAL
CALCULATIONS
COOLER T.I.
1969 Kellogg Ave.
Carlsbad, CA 92008
Job No: 18-535
July 10, 2018
CBC2018-0467
1969 KELLOGG AVE
KELLOGG FLOWER MARKET. WAREHOUSE
WHOLESALE. PRODUCTION & DISTRUBUTION
27315 Valley Center Road-Valley Center, CA 921
Email: wynneng@wynnengineering.com -Los An
2120921200
8/15/2018
CBC2018-0467
JOB: 18 -2-oS
WYNN ENGINEERING INC. -27315 Valley Center Road SHEET NO.: OF:
Valley Center, CA 92082 CALCULATED BY: DATE: (760) 749-8722
(760) 749-7493 Fax CHECKED BY: DATE:
SCALE:
Table of Contents
Structure Loading
Vertical Loads 1
Soils Parameters 2
(El Structural Roof Plan 3
LARR25368 4-7
Check !El Jolata 8
Penal Anall!la 9-11
Check (El Slab 12
EYBl!!!ralor SUf!l!!!rl 13-15
JOB: li5 -:s:3~
WYNN ENGINEERING INC. (
27315 Valley Center Road SHEET NO.: OF:
Valley Center, CA 92082 CALCULATED BY: >04-DATE: "I l'b
(760) 749-8722
(760) 749-7493 Fax CHECKED BY: DATE:
SCALE:
GRAVITY STRUCTURAL LOADS
ROOF LOADS Load (psf)
Dead Loads 11.5
Built Ue Roofing 4.0
Plywood Decking 2.5
Insulation 1.0
Cooler Ceiling 3.0
Mechanical 1.0
Live Loed 20.0
Total Load 31.5
JOB: !'is -'$3.$'
WYNN ENGINEERING INC. "'2-SHEET NO.: OF: 27315 Valley Center Road SQl't...-"!ti Valley Center, CA 92082 CALCULATED BY: DATE:
(760) 749-8722
(760) 749-7493 Fax CHECKED BY: DATE:
SCALE:
SOILS PARAMETERS & LOADING
Parameters B-on 2016 Calllomla Building Code {!1610.1 & T1606.2l
General Solla Parameters:
Allowable Net Soil Pressure at Minimum Depth 1500 psi
Minimum Footing De~th 12 in
Minimum Footing Width 12 in
Coefficient of Friction 0.25
Passive Pressure -EFP 100 pcf
Retalnl!!!I Wall Solla Parameters:
Allowable Net Soll Pressure at Minimum Deeth 1500 esf
Minimum Footing Deeth 12 in
Coefficient of Friction 0.25
Passive Pressure -EFP 100 l)Cf
At Rest Pressure -EFP 60 pcf
Active Pressure • Level Sloe• • EFP 45 l)Cf
Active Pressure -2:1 Sloe•· EFP 65 l)Cf
0
~
(-z,) A.>€ t...)
(1,) -A.,f~
' .,
~•~bc""st,)~s (t-J/tlc
(cJ,J l)lfAAJo-S.
.!,
~
·,t _.,
.. ,
' . ., ~ :i;
' .,
.!,
,
,vr,o CAc:.~ G
.'.!1 :
,-;;,,
:i;
C.o>.:>l, e-~ ~oR c; MOV€b To ~tvb)
I ?c><) .. Mt', I~~ #JA,J~ ~/A I c:.p~l>~~
Nfc:,Jet> TO ~o,..\b)
i--,.., ·HM.-·SG+E»U..E --· . I I
I
I
I
C-J 48 G 4N 10.5K :i7.0K c-• 48 C 4H. 7.01( 57.oi<
GIRE>ER NOTES:
1.
2.
J,
'TC' A.xw.. UW)S GIVEN IN Kl:PS.
'TC· AX1AL ~ DENOTES SElSMIC Lo.trO IN TOP CMORO.
'TC-AXIAL LOAD WAY 9£. En'HER COMPRESSION ~ TO&ON.
j.@J:
·I 7.
8.
S£t: DETAl.S '°" ~ 1-9"(> TRANSF'ER CONFlCURAllONS.
SEE 'SIEEL ~-_-.-· ,ioosT ClfUl£RS' NOTES ON S>j££T· S-1.
AOO LO-.O Of 1..,000·.LBS .• .-f Nl'r P:ANEL POtNT stW.1:.-_BE
INCORPORATED tNTG -QROER--l.,0i,\ON) AT ALL BAR JOtST .. CIROEJIS. . . . . . . .
ALL QRO€RS ~;HA~. A SEAT DEPTH-or 6"'--.U.N:o'.
(J(AMPt£ 0. STEEi. GlROER. CAU.-ooT IS. AS rou.ows, .
I
I
1 ~ROER SERIES -Di -l'IPE
·b/ I
GIRDER DEPTH . ffui,~ OF "_: • ·
IN INCHES ------...__ r--J0fST SPACES . ·•
48 G ·6N 10.·4K ·... ~
_/: \_ TOTM. ·LO•ll"AT £At><.
PANU POI~
-----
BAR JOIST SCHEDULE
MAIi!( JOIST OESIGNAlKiN · rop· C>tOltO (TC)
AXIM. LO;.o,·
J-1 28 K 232 / 128 9.5K
J-2 18 K 26• / 160 . 9'51<
11.7K. J-3 28 K 232 / 028 ·--~"oc::=-... ._ . ..,
J-4 24 K 164 / 160 9.51<
JOIST NOTES:
1. TOTAL LO...o / LM LOAD VALutS ~ IN LBS. PEf UNDl. FOOT.
2. 'TC' AXIM. LO.-.OS GNEN IN· KIPS •.
3. 'TC' AXIAi. LOIII> DENOTES SEISMIC LO.O III TOI' CHORO.
4. 'TC" AXIAi. LOAO WAY l!E EITHER C0MPR£SS10N. Oft. TtNslotl.
5. ~~l~~~ ~:,r ~,UA!l~
MOMENT OUE TO ECCEHTRICJTY. •
6. SEE OETM.S rOR ;u ·UlA!) 1""NSF'ER CONAGURAllONS.
. ADO lDN) Of' -250 LSS. AT A.HY PANEL POINT
:~
lt-,.o
,...J :·, "'. w ~ w u ....
·"' ;O f&: ,;;;; 'o
-~
~ "' i
®. SEE 'STE£L ..K>ISTS A JOCST•·~O(RS• NOTts ON SH£ET S-1.
i~L s:,.,:~TEl) INTO BAA JaSl l°""""' I I
9. ,U JOISTS SHAU HAVE A SEAl OEPn! Of -3" U.N.O.
1 O. OAMPU: Of BAA JOIST CAU.--<lUT IS AS rou.ows
JOIST OEPIH •
•M 1NCM£S ------...__. ~ TOT"'-l0AO
26 K 216 / 128
JOiST SEIOES __/ \__ U\/E l0AO
l'l1'E
½ li-
~I j ...... s.. -
-<S j; ~ ~ -~, ti, h ' ·!q --l ; H ~-h ~
C2J
BOARD OF
BUILDING AND SAFETY
COMMISSIONERS
VAN AMBATIELOS
PRESIDENT
E. FELICIA BRANNON
VICE.PRESIDENT
JOSELYN GEAGA-ROSENTHAL
GEORGE HOVAGUIMIAN
JAVIER NUNEZ
CITY OF Los ANGELES
CALIFORNIA
-ERIC GARCETTI
MAYOR
DEPARTMENT OF
BUILDING AND SAFETY
201 NORTH FIGUEROA STREET
LOS ANGELES, CA 90012
FRANK BUSH
GENERAL MANAGER SUPERINTENDENT OF BUILDING
OSAMA YOUNAN, P.E.
EXECUTIVE OFFICER
Diversified Panel Systems, Inc.
2345 Statham Blvd.
RESEARCH REPORT: RR25368
(CSI 13030)
Oxnard, CA 93033
Attn: Richard Bell
(805) 988-5070
Expires:
Issued Date:
Code:
February 1, 2019
February l, 2017
2017LABC
GENERAL APPROVAL -Clerical Modification and Renewal -Diversified Panel Systems
Inc. DPS 500 Series Steel Refrigeration panels for walk-in coolers, freezers and processing
areas.
DETAILS
Diversified Panel Systems Inc. DPS 500 Series panels consist of26 gage galvanized steel
skins, meeting ASTM A446, and have a core of expanded polystyrene beads manufactured by
BASF Corporation as approved under ICC Evaluation Report No. ESR-1498. The panels are
4" to 12" in thickness and vary in width up to a maximum of 48".
The panels are approved as structural wall and ceiling panels for use in interior, non-fire rated
walk-in coolers, freezer and process areas.
The approval is subject to the following conditions:
I. The panels are approved for use in accordance with Section 2603 of the 2017 Los
Angeles City Building Code and shall comply with all requirements therein.
2. The foam plastic shall be separated from the interior of the freezer or cooler and from
the room in which it is placed by use of ½-inch gypsum wall board, ½-inch plaster or
other approved thermal barrier meeting the requirements specified in section 2603.4 of
the 2017 Los Angeles City Building Code,
EXCEPTION: The thermal barrier is not required if the cooler or freezer floor area
does not exceed 400-square feet and the foam plastic insulation does not exceed a
thickness of 4-inches.
LAOBS G-5 {Rev.1/10)
RR25368
Page I of4
AN EQUAL EMPLOYMENT OPPORTUNITY -AFFIRMATIVE ACTION EMPLOYER
Diversified Panel Systems, Inc.
RE: DPS 500 Series Steel Refrigeration Panels for Walk-in Coolers, Freezers and Processing
Areas.
3. The panels shall be manufactured in the shop of a City of Los Angeles licensed
fabricator. Fabrication in unlicensed shops will invalidate the approval.
4. The panel core material shall have a density of 1.0 pcf.
5. The panels shall be used only in areas where combustible materials are permitted by
code.
6. Daily tests of the physical properties of the core material shall be performed and
records of such tests shall be maintained and provided to the department upon request.
7. Fasteners used for the various connections and fastening to the floor shall be the
product approved by City of Los Angeles.
8. Complete design calculations shall be submitted to Structural Plan Check Section of
each job. Plans and calculations shall bear the stamp and signature of a California
registered civil or structural engineer or architect.
9. Maximum wall panel height shall be limited as follows:
Panel Maximum Wall Panel Height
Thickness (feet)
(inches) 300 plf Axial Load 200 plf Axial Load
4 16 20
5 20 24
6 24 28
7 28 32
8 32 35
9 35 35
10 35 35
12 35 35
RR25368
Page 2 of 4
Diversified Panel Systems, Inc.
RE: DPS 500 Series Steel Refrigeration Panels for Walk-in Coolers, Freezers and Processing
Areas.
10. Shear wall and diaphragm shear values shall be limited as follows:
Maximum Height Allowable Shear
to Width Ratio (nit)
2:1 50
I: I 100
0.5:1 200
11. The Maximum allowable ceiling load (psi):
Panel Panel Thickness (in.)
Span 4 5 6 7 8 9 10 12 (ft.)
8 40 40 50 50 50 50 50 50
10 27 30 30 40 40 50 50 50
12 20 20 20 30 35 35 40 45
14 15 15 20 20 25 25 30 35
16 12 15 15 15 20 20 20 25
18 10 10 10 15 15 15 15 20
20 8 8 10 10 10 10 15 15
22 6 6 6 9 10 10 10 10
24 5 5 5 7 8 8 8 10
26 4 4 4 6 7 7 7 10
28 3 4 4 5 6 6 6 8
30 3 4 4 5 5 5 5 7
12. Panels shall be provided with a permanent label specifying the fabricator and surface
burning characteristics of the product.
RR25368
Page 3 of4
Diversified Panel Systems, Inc.
RE: DPS 500 Series Steel Refrigeration Panels for Walk-in Coolers, Freezers and Processing
Areas.
DISCUSSION
The clerical modification is to update the product approval to the 2017 Los Angeles Building
Code.
The report is in compliance with the 2017 Los Angeles City Building Code.
The approval is based on tests and engineering analysis.
This general approval of an equivalent alternate to the Code is only valid where an engineer
and/or inspector of this Department has determined that all conditions of this approval have
been met in the project in which it is to be used.
Addressee to whom this Research Report is issued is responsible for providing copies of it,
complete with any attachments indicated, to architects, engineers and builders using items
approved herein in design or construction which must be approved by Department of Building
and Safety Engineers and Inspectors.
QUAN NGHIEM, Chief
Engineering Research Section
201 N. Figueroa St, Room 880
Los Angeles, CA 90012
Phone -213-202-9816
Fali -213-202-9943
EB
R.R2S368
TLBl7000to
R02/06/2017
2602
RR25368
Page 4 of4
WYNN ENGINEERING INC.
27315 Valley Center Road
Valley Center, CA 92082
(760) 749-8722
(760) 749-9412 FAX
JOB /'8:-S-::? r:
SHEETNO._$:--"'--------OF'------;-----s t> .,,_ b I 18'. CALCUL.ATEDSYr---'c:::..'..!C.:....::=-------DATh----"'----'--"-'---
CHECKEDBV ________ DATE _____ _
SCALE ________________ _
've111--r-Pcv ,C€:) ·••·•·· s~-t:~+s .. · 0 1~. l~ ' . ~-t--...
! ·c~~
C f'6<--• a fl\ lec:;"t ;:!CJ• 1tf3 . s4,.--m, ~£s.r....Eil)
.. zi'2-~ .. ia,-,-J,.L L~ f t~~·-1•.· · Liv~ l.o"ti~
• A-Ls.,p
47,(..lt,
P ~uo:'1v) G~') (3 ihr>
--d 1:-.
~
.. 'J'o~s'ts-
~'l>Jr,u"t"' '-:o-tb
. 12~~
: """ is;;,. ·. ··•
. '
D PRODUCT 207
WYNN ENGINEERING INC.
27315 Valley Center Road
Valley Center, CA 92082
JOB-~• ,,__/..,l_-....;.r":--'!1.:;,,~"'--"-· ---------, ....
SHEETNO, __ _;"'\.!.... _____ OF---..,.---
Vl.i (760) 749-8722 CALCULATEOBY' _ _,,S,,_,D~1t..---____ DATE
(760) 749-9412 FAX CHECKEDBV ________ DATE _____ _
SCALE f'..) \ ":,
'f-'A/0€L. l)E:;-,S,"'-W 1:>ATA
~;,Arv E:: L. IA5c I c.:..-rr -~ ~ 'P-..~
'? 'N ° I C> 'PS~ ( V\l I'\; 1.. \-. ~RE:~ so 'R <e)
-Z:<o GA. A:'S,11/l A-t.J'-{l:, ':;iT'l£€l. FAC.11.)(:,. ·,::."' C),C::,\C~ \/'-.J
b.., I -z._fl \.),-.} 'T w ,, -:)1 \·.\
C. ;;. Cc, 11 'PA A..i E (.. 'T rl IC.¥.: ,0 E "S 5
G-s ~--z_ot,s 'F'~, ~ r-1:'i<, • fV'o'\:,.
""""' '-{,{ ?'$\ C...OR'=' "b'r\"K.
VJ. "'" I oo ..r I q..~. 1> 11; P r1 "$ 'r\ ~. , '-l "t e::, o '< """"
? A == q 00 ;tr WA-1,--i.,._ AX IP,;\.-. \.0 ¥\ ';:::,
6-tt:O::. Cg 11_1,vG,, ?fl /\JEL-':::,
L= \7,S' ~= :::s~,__, \O\.,._ = \~ ?Si;.
N\ =-,t" r'!:,.,._ 17.St.. =-49 'o R.+· \vs
.(\, = M -::. 4 q f> "'Z. =-'-I "'J Co. C\. 'f'"i, ,
l:,]{L><f. 1-Z.><lo•,DC<\
\{= \2., 'I'. 17,c;'.,;. \l'--1, ~ z..
'I' ::-\ I ':\ !0-"' \. 'S '\ 'f '5 I . L._ 4, { f~ I
"" I '2.. -Z b "" = c. ,a t= ., 1,Q"" o""' c ~ "--c ,. .(..: "' zq x Io " . o \ '\ -. J..: -7 ·1 o " z. z.
b,.--:;. l,@75'-41" k-4 (1~ ,Ob7x.t:,'\
'O L"-•&s ~~ )
A"' /.~"1';)"-I:>• 17,S'-((l..L ,6h1x '-j.'31'?,~10"')
"f ,"l I ia, X t cfo -, I 7 .,;'-~ c.<>.',3 "-(,:;,
~=C>,<o~1.J .L 17,$X:l::Z -=.\,\bl11d · OK . , ,ec,o
( ~ II ,n A • I c <-_CL ( F. \ L--\ W ~ I-,..,. \''.J '--' t...: _;, 0~
J08 I g .. S-!,r: WYNN ENGINEERING INC.
27315 Valley Center Road
Valley Center, CA 92082
(760) 749-8722
(760) 749-9412 FAX
SHEETNO.~ft>~------OF·----,----
CAUlULATEOBV . SJ)fL_ OATE_..,.,Y/'-'1""3'-----
CHECKEDBV ________ DATE _____ _
SCAtE _______________ _
.f,1.. ..,
1--\-=--Z... ""t. ~ :.,. y A -=-l '.2_:, >< \ 7, S 4--1,-= 'Z-Z6 -(tr,.'A,Y... '')
C,v\l'-..l.,, C~11 'P'NA\...\...' I D'P"6~
1'/1, "" -k-,.. l o >< -z -z. "'-:cc &:, o S '\"'"I"' · 1.ie .-::,
.i;i't,.,, <0 0s x, '-'-'"' c;'3c,, ~ \
I -Z. -" lo " . 0 \ <=I.
C. ,-\ EC ;c,. CO W',_'11:, \ i,..) e'."C> \,-0 Au\ t--\ <o
'2307 -1c -z:-z..B -::,O,'-l"'tS L. \.C..'I o·~--z.-, ... o=o "roe
C:.11 1A11''-.b\o :Pt).t:,Jf;L..$ 01<
l.....Ps:TE.Rfl,\..., A t:,l A b~Si \S
f'w .,,, IO p~ X. ~ -i lC' ,J/s/Q-~-i, 70~ "'I
-sc 1svH<C -CA·,p__:
LA.,· ~-3 z., ,&<o 'iie, \ "'!;, \..,CV.::, Ccc-. -a. -I, '.1 , \ '? Z. '5'-j -S I TC: C.. i,...fl, '$<:, := °i:::,
12..:: -l. S :I:.-c.. \ ,o --5'.,,"' 0,9 56 :Sv1r,s ~ I .o--ro '=' i:;,s =-o,'n ~
C ~ " 'J:t.p -::. 0 ,--, 1 7:, =-o, z.. 'c. s 1-, '-I ==-, -z s s z., \t--l
7,'i,/ l,C,
C€.i,_u...,c.. ti1-= (.'5s '"' 701 ') • ":>,->-$.i;. ,. \ \ <::,c,o ;o,.
WA\..\.. D1~-= ( S ":>, >< t.. "' r o' ~ Z..) ( i:z:/,:_') ('? y7,;;,s;') -= ~ Z. "60 ~
z. w -' \ C\. 'oC..."'C> *
Y.,. . -z..es z.. ( 1 qe,~") -;:c c; ic,'-l 1 :j:I:.
-~ SC..'-17 " :, :=c I .Y7 f>S.l? 11'5So
C.';:\F[ :6 Ct-1.LI yG::, 'Pl l:'d?H B Bl',?YV},
I I ,;>' V--:. 1,--{"7 7-s~ >< -.;.,, " ib : c; C,, ~(.)
-r~ St.l-0 '>I, ro' ::;.. CJ o 1 *
'2," <5'5'
R .. ::: CjO_) -:.-l-4 ;Lt? r'~ \ . (z_.,.~ ):t', C>' ~
tAw;,,. "' 37;,0.(;;;c;;r,;:·1 (:zA:B)(6,t11'l') _ ~7SS 41" > C::,0\-11,:6+::
'lc,'7
0 PRODUCT 207
WYNN ENGINEERING INC.
27315 Valley Center Road
Valley Center, CA 92082
JOB~....,1 s_-..,;;;5~~.:;:;,_<,.._ _____ .:..__ ___ _
11 SHEETNO. _____ ,__ __ OF---:-;----
CALCULAlEDBY~-S~O&-=·=-.----DAlE_~6 ... /~'~f~--(760) 749-8722
(760) 749-9412 FAX
CHECKEO BV ________ DATE _____ _
SCALE---~-------------
5bCeD¾--c -
-Z:.826 :!le-:::
~5~1--
? 1--\ EA-;'?-\fll I"\; Llr-."')
c;o:;;.' WAL~
\( -:: s l, '--\ ::r .,,. -=--z "& z. '-', ""'
'Z....
1 b O ""'/q"' ,c-D'? -\·i C\ Coe-,-:--, (~
zoe.:, ·•J:yq~ r:,..t_..,v, ,,.).t\(:,,1---1···;,--:-<.:-. ·_..,.)·. ~-', O,S-: \
l,.._x::,-.,:2.<.:.,T C ... Ac<:,1"::' S$1-'r:..,·r 1 ~··•--41'
,r~ --Z.<o c: '-I ,t / l-f I ~-1:-""' Ce:,°'-.. ii,,/q-J.-< loo *A"-, _ c::, ',::..__
Wf'-'rLL. '\p~ C.C:,t-...l1'Jec,..,·1ok I
'-{"' M A-1'-. :c Ge, 'i ;,tc / q. -'-A-N G W5 'tD v::, A'--\-
;,<,"' Z,.x'-{'Elti>_ \,"?°1~-04 -
U~t:' Uo GA -Z,1
\ 2,_;'1 A f',lC~k(;;;'' 1.,.J/ P' e "R::fc "':, !'2'. '? .. 'coc
A NG.~ TR c,.o10c y::, •z:-r-€""
V' = (,, q ~/s;,-:,-
(.,)~ ff U-) +-\U-"'['\ 0'2s\_l/t;; ff 1-S lC-DA.lf
C.,l (.l, e 'S, f< \ [p (,, 7:,)
CA'6-f Z.C..0 1> ( R-'
( C/<i 11 (3.M"f, @_ 'Z.4 ,; Q(_
C,.€1 u t-1 Ce ·r-o '.Bef\I"'1 ,., c,, •Ye:c -,·,o"-1
X."' "70,1;, -::::: \ ,l Co ~+
,;; L,
\ ; .... /(
I 76'\'.'.'. ..
D PROOUCT'xrt
,r
0
WYNN ENGINEERING INC.
27315 Valley Center Road
Valley Center, CA 92082
(760) 749-8722
(760) 749-9412 FAX
JOB__,.....;./.;;,.'8...;~$_;;;,;3.:;;~::;.._ ____ ..;,.... ____ _
/2.. SHEETNQ.._....._.:...,;;. _____ OF---~--
,5)),,i_ ,1lo CALCULATED-._ _______ DATE--:ill,/jt.,:/,::o __
CHECKED BY ________ DATE _____ _
SCA~----------------
? c,_c--;l< ' fV\A'!----0-..J .'.:: @_
-
I __ ,/'
,/
,' ! 1 /-· '
/ /'
L~ '
/ '
,
,t
'{
'
,,
l/
/'
I'
J e ~<SQ..,_ -7-.. , '3 ~ ~ -1--"' Z..<t/£
l <S CO 'f"6','
.'r" fl ! ' ZE ,GB . -2. '1 --l.f, 1::/o
t-(, r,f2:</ z. -Z , 3 t..f ,,,
I 2' , ,.
b
l I Z. ; ,?' ,,
::µ!:I l I <
' '
-;, ::,01 rr 1
'-I ""' T
7~7",, <S """, ;1:i:. I ,.J ,.._ n a / p"'-1 -------'--', ·o I 1<:? .;, 77-.,n'¼
rt..''><: 1. z.,''" '-(,./' p l--r-\:-TE o ~0 (e,.;') e,, u -51.f"tts
\ ";i C::> ~. t' e:? l,,"0 R ,s_;: c.,V£ r ·, •--:;... I
t) 'SC A;_"'.-f\\-:.'----C.O'-.U ,,., l,J !.-<'.)( __ p·, ·,:· . ~V,J ~
0 PRODUCT 207
WYNN ENGINEERING INC.
27315 Valley Center Road
Valley Center, CA 92082
(760) 749-8722
(760) 749-9412 FAX
,, .. .l ... : . :·;
......... ~VA't~O,v•ft<=>~ ... SQfr?11.tii=•·
. . : , ... ' : ', .
! :. .1
.. :ff ':"~!~~it: • . ....... ··••'+· .';\' tit ('~~tJ ~, e,, ~.
; '
JOB_.!.,a"'--.,.s<----::r:-=------------
SHEETN0._.,_1~1._ ________ OF ________ _
CALCULATEDBY_...:~=O., .. :c._~-----DATE_-=~=-../_.t,£,___ __ _
CHECKEDBY· __________ _ DATE _______ _
SCALE _____________________ _
i : . . i
p~fMti. c'"') ··· l7vt. ... ts:,i.rl _,
$.,...r.f .
·ib~.·•.1 ~ ~;J ... , ....•.. /,le/
J ··················· ,.,
• ..... :
j .·· ···~· ~·S't->•· . .. ,.c.. ... ··· 0
!~
D PRODUCT 2.07
6-FAN
Air
Defrost
Uquld
l{RAMEl\
Job Name:
Customer Name:
Architect/ Engineer:
Unit Model Number:
Unit Quantity: .. .
HEAT TRANSFER PRODUCTS GROUP LLC
3885 Crestwood Parkway / Suite 500
Duluth GA 30096
(P) 800-288-9488 / (F) 256-259-7478
https://kramer.htpgusa.com/
Job Location:
Order Number:
Prepared By:
•· .. Tagging Info:
Date:
SUBMITTAL DATA SHEET
New Low Profile Unit Cooler
Ale Defrost
For Record Only
For Approval
. '
Thursday, June 07, 2018
~ d~ SLOTS
lr,i::::=i:=::::::::::::::===========~=============:ic~!r,t1,i ELEcmJOl · o KNOCKOOTS
I~ •O
•O
0 2-
-2--11Yz-SUCTION
Back side
UNIT MODEL
KL6A330
KL8A390
¾-t◄ NPT ORAtl
CAPACITY (BTIJH) 0 10 DEG TD
S.turllfed Suction Temp (SST)
R-404A R-407A & R-448A/R-449A Qty
+25 F +25F Fans
33,000 38,800 6
39,000 45,900 6
PHYSICAL DATA
Unit Refrlg Conn (ODS) Drain FPI Conn Modal Liquid Suction Ext Equal
KL6A330 6 3/6' 1-1/8' 1/4' 314-14 NPT
KL6A390 6 3/6" 1-1/8' 1/4" 314-14 NPT
ELECTRICAL DATA
Voltage Voltage Phaee Her1Z EC Mir PSC Mtr Total Motor Ampa
Code Amps Ea Amps Ea PSC Mira EC Mtrs
A 115 1 60 0.8 1.0 6.0 4.8
D 208/230 1 60 0.5 0.5 3 3
F 480 1 60 rva 0.4 2.4 N/A
~t ~gy_ ~n I I Mod•llVP•
Type of Defrost Refrtcer1nt Type
A-Air Defrost ... R404A E • R441A/A441A
E•E1ectrlc Defrost 4 FPI 8• R407A F•C020X
Fan
Diameter
12'
12'
Refrlg
Charga
7.8
7.8
H•Hot Gat J'4'1pe
I Fino Per Inch
6 FPI C• R407C G • ctycol (consult f1ctory)
Gs.Hot G1.sRev.O,Cle ~ OcR407F
I ll\JH In Hundreds ~ 1 Revision Code VolU11• Code
A• 115/1/Ml L• 100/1/50 Motor Type D • 208-U0/1/60 M • 200-220/1/SO
E • 208-230/J/Ml N • 200-U.0/3/SO P.PSC
E • Sln9'1 Spted [CM
0 • Dual Speed E.CM
MMTPG
FAN DATA
CFM Air Throw
4,650 25'
4,850 25'
Net MCA MOPO .. , __ ..
230vor460v l30vor460v
257 Lb's • J 15 20
-"262 Lb's 15 20
Pre-ANembly Cod•
Blink• Standard Confl1uradon
T • mou"tad 1XV only
l • mounted lXV, W , T-SUt
M • Master COflfl&uratlon with TXV, US,
T •Stat and copper tee
I
N•w Low Profile Unit COol•r Air Subm.
. .
3/8 MOUNTING HOLES
(4) 318 MOUNTING HOlES
,4~ 38 der-
6 ~A 48:ktiDRAIN
1 FAN: -050
(4) 318 MOUNTING HOLES
•
1~tT~ : 3~+
2 FAN: -075,-100
Other Connections
Liquid -1 /2" OD Hot Gas 1 /2" OD Drain 3/4" MPT
3
Dimensional Data
*All dimensions are in Inches.
5 FAN:-270
1201-----------t
6 FAN:-340
Ext. Equalizer 1 /4" OD
STRUCTURAL CALCULATIONS
Date:
Project:
Client:
Designer:
Project#
August 15, 2018
Tenant Improvement Project for Kellogg Flower Market
1969 Kellogg Ave.
Carlsbad, CA 92008
West Coast Design, LLC
29643 Nandina Dr.
Escondido, CA 92026
West Coast Design, LLC
29643 Nandina Dr.
Escondido, CA 92026
Note: These calculations are invalid unless bearing a wet stamp and signature
3578 30th Street• San Diego, California 92104 • (619) 236-0595 • Fax (619) 236-0557
wwwm, .. •·cec 2.o 1s-o ,,. 1
Governing Code:
Construction Type:
Occupancy Group:
Concrete:
Masonry:
Mortar:
Grout:
Reinforcing Steel:
Structural Steel:
Welding:
Bolts & Threaded Rod:
Sawn Lumber:
Solid Web Joists:
Open Web Joists:
Manufactured Lumber:
T J Shear Panels:
Steel Strong-Walls:
Wood Strong-Walls:
Glulams:
Soil:
Soil Report:
DESIGN CRITERIA
California Building Code, 2016 Edition
Type V {B)
B
F'c = 2500 psi, No Special Inspection Required {U.N.O.)
ASTM C90, F'm = 1500 psi, Special Inspection Required {U.N.O.)
ASTM C270. F'e = 1800 psi, Type S
ASTM C476, F'c = 2000 psi
ASTM A615, Fy = 40 ksi for #3 and smaller ASTM
A615, Fy = 60 ksi for#4 and larger {U.O.N.)
ASTM A992, Fy = 50 ksi (All W Shapes)
ASTM 36, Fy = 36 ksi (All Plates, Angles & Channels) (U.O.N.)
ASTM A500, Grade B, Fy = 42 ksi (HSS Round)
ASTM A500, Grade B, Fy = 46 ksi (HSS Square & Rect.)
ASTM A53, Grade B, Fy = 35 ksi (Structural Pipe)
E70-T6-TYP, for structural steel (Fy = 70ksi)
E90 Series for A615 Grade 60 Reinforcing Bars
Shop welding to be done in an approved fabricator's shop
Field welding to have continuous special inspection
All welding shall be done by certified welders
ASTM F1554, Grade 36, Fy = 36 ksi
D.F. Larch, Allowable Unit Stress Per C.B.C., Current Edition
iLevel Trus-Joist, ICC ES ESR-1153, ICC ES ESR-1387
iLevel Trus-Joist, ICC ES ESR-1774
ilevel Trus-Joist, ICC ES ESR-1387 (Parallams, Microllams & Timberstrand)
ilevel Trus-Joist, ICC ES ESR-1281
Simpson Strong-Tie, ICC ES ESR-1679
Simpson Strong-Tie, ICC ES PFC-5485, ICC ES ER-2207
Douglas Fir or Douglas Fir/Hem (24F-V4 Simple spans,
24F-V8 Cantilevers)
Allowable Bearing Pressure = 1500 psf
Active Soil Pressure = 35 pcf
Passive Soil Pressure = 100 pcf
Soil Density = 110 pcf
Coefficient of Friction = 0.25 psf
(NIA) Natural Undisturbed Earth
DESIGN LOADS
EXTERIOR WALL LOADS
Exterior Wall Dead Loads (Concrete):
7.5" Thk Reinforced Concrete Tilt-up Walls ....................................... .
Total Exterior Wall Dead Load ................................................................ ..
Exterior Wall Dead Loads (Stucco):
Studs ........................................................................................ .
Gypsum Board ......................................................................... ..
Exterior Finish ............................................................................. .
Miscellaneous ........................................................................... ..
Total Exterior Wall Dead Load ............................................................... ..
INTERIOR WALL LOADS
Interior Wall Dead Loads:
= 94 psf
=94 psf
= 1.1
= 2.5
= 10.0
= 2.4
= 16.0
Studs... .. .. .. . . .. .. . .. . . .. .. . .. . .. . .. . . .. .. . .. . .. .. .. . .. .. . .. . . .. .. . .. . .. . .. . .. .. .. . .. .. . .. .. = 1.1 psf
Gypsum Board ... ... ... ... ... ... ...... ... ... ... ... ... .. . ... . .. ... ... ... ...... ... ... .. . ... = 5.0 psf
Miscellaneous............................................................................. = 1.9 psf
Total Interior Wall Dead Load .. . .. . .. . . .. .. . .. . .. . . .. .. . .... .. .. . .. .. .. . .. . . .. .. . .. .. . .... .... . = 8.0 psf
psf
psf
psf
psf
psf
JOB M>r-*¾
SHEETN0._(,._:1)7\ L__ ____ OF---.---.--
CAlCULATEO BY______ DATE ,:':> } l:3 / I b
CHECKE013Y _______ OATf ____ _
SCAlE _____________ _
·-v.J ColJ cU: ltr Cu.--C. 1'f I ~TIµ & "(, w-u f' \JA-U.. G R. I C A
-P•c-= ~f\\. I
-l k -::: (, 'S II
(1tJ~ T~'i2 A~-C.L.T
fl..4-...l,.S. \ "I "I .r)
•
r// I
_\4......,A-:::..,L,.,(,,._._.Fg..::::,l..""'fkco::;.o.1,::'_A....,JJO-=.clu....-W=ui :1$..§<A 1..45)
. .1, t,.,o' ,111!:,.c----------------~ .. -.
-----------------·-----·-
0~ 3578 30th St
,.. •• c .. rn: INC. San Diego, CA 92104
619.236.0595
Description : B1: LINTEL@ GRID A
,::' .C()(iS:'fft./:~lf!!N(}~S~.:. ,
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combination Set : ASCE 7-10
Project Title:
Engineer:
Project ID:
Project Descr:
Printed: 13 AUG 2018, 11 :02AM
··Material 'Prol)!ttte1·~ ,: .. ;:,,, .y·~::~:~..:::· ·' -~----------------------
Analysis Method : Allowable Strength Design
Beam Bracing : Completely Unbraced
Fy : Steel Yield :
E: Modulus :
Bending Axis : Minor Axis Bending
Span= 6.50 It
----------------•··-.. -·----·--··----------
50.0 ksi
29,000.0 ksi
-------~----' .:~ppl'.itiiill:4.idif:·'' "½lllii !f •!;:,,-,i/:t ~•;; .;:l/):_ '. , ·,,;; ·~": ________ S_erv_ice_lo_a_ds_e_n_te_r_ed_._L_o_ad_F_ac_t_or_s_w_il_l b_e_a....cp...:..p_lie_d_f_o_r ca_lc_u_la_ll_on_s_.
Beam se~ weight calculated and added to loading
Uniform Load: D = 2.180, Lr= 0.040 k/ft, Tributary Width = 1.0 ft, (W)
:Q~SIGN~$'f!M,fft~£)1}.ll(:t:-::~-·~1''~~Z:);, ___ ,.: ~·· ·~~-c-c---,~~-=--~--
Maximum Bending Stress Ratio = 0.903 : 1 Maximum Shear Stress Ratio =
Section used for this span HSS8x3x1/4 Section used for this span
Ma : AppJled 11 .816 k-ft Va : Applied
Mn / Omega : Allowable 13.079 k-ft Vn/Omega : Allowable
Load Combination +D+lr Load Combination
Location of maximum on span 3.250ft Locallon of maximum on span
Span # where maximum occurs Span # 1 Span # where maximum occurs
Maximum Deflection
Max Downward Transient Deflection
Max Upward Transient Deflection
Max Downward Total Deflection
Max Upward Total Deflection
Overall Mf\Ximum 7.271 7.271
Overall MINimum 0.130 0.130
DOnly 7.141 7.141
-+0-+lr 7.271 7.271
-+0-+-0.750Lr 7,239 7.239
➔-0.600 4.285 4.285
Lr Only 0.130 0.130
0.007 in Ratio =
0.000 in Ratio =
0.416 in Ratio=
0.000 in Ratio =
10,497 >=360
0 <360
188 >=180
0 <180
Values in KIPS
Design OK
0.377 : 1
HSS8x3x1/4
7.271 k
19.262 k
+D+Lr
0.000 ft
Span# 1
f{:: 7!1/.,i
I
'
'
//, ,,,,,
SHEETNO, ________ OF _____ _
CALCULATEOBY _______ DATE" _____ _
CHECKEOBY ________ DATE _____ _
SCALE----------------
-If-A Tf A--U+-EO -re:. CoN tt~ -r ~
~ / 13'2.A-C.eO e.. z..o •
I i-J. e,~µ~-n,.
'f?iL=c ~~,_.f.(+t)(t-3,0')+-l~~+(i)J(-¥)
f'~ = [ ~.(' (4 )J l\SJ C 1% >It-= 708j
( ~ ~ak..\uil-~)
0~ 3578 30th St
A • San Diego, CA 92104
619.236.0595
Project Title:
Engineer:
Project ID:
ProJect Descr:
C9Bf~;ft:efiiwi{ ·. t/.;!k1/. t __ ._•:r.:~;;:\;;,;:_~:~/_)(\;:l~: ----...c.....:.....;;.,••:.._::·:"""':..._,;_ _____________________ _
Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10
Load Combinations Used : ASCE 7-10
J;',tQ,eneral:'lnf9rmiffo!1 ,r;f,':c:' ;';'.' J{,:f ::··•,,,· '·:),tl.fl::'r,:-,;i,t\:;-
Steel Section Name : HSS8x2x3/8
Analysis Method : Allowable Strength
Overall Column Height 7.5 ft
Top & Bottom Fixity Top & Bottom Pinned
Steel Stress Grade Brace condition for deflection (buckling) along columns :
Fy : Steel Yield
E : Elastic Bending Modulus
36.0 ksi
29,000.0 ksi
Column self weight included : 167.TT5 lbs• Dead Load Factor
AXIAL LOADS ...
P: Axial Load at 7.50 ft, D = 7.086, LR= 0.130 k
. DW.G'NfSU~RY.i\ ~:,::c;g,~:;~i 'i '\i~i•I/:./
Bending & Shear Check Results
PASS Max. Axial+8ending Stress Ratio =
Load Combination
Location of max.above base
At maximum location values are ...
Pa: Axial
Pn / Omega : Allowable
Ma-x : Applied
Mn-x I Omega : Allowable
Ma-y : Applied
Mn-y I Omega : Allowable
PASS Maximum Shear Stress Ratio=
Load Combination
Location of max.above base
At ma~imum location values are ...
Va: Applied
Vn / Omega : Allowable
·:(~ Lo'iid'Coinblliltfon~•uit.V/~:~ ,.-:··· ·:. }· -;<·'.U~:;i:,., :r.:.c• t
X-X (width) axis :
Fully braced against buckling along X-X Axis
Y-Y (depth) axis :
Unbraced' Length for Y -Y Axis buckling :: 7.5 ft, K = 1.0
Service loads entered. Load Factors will be applied for calculations.
0.05937 : 1
+D+Lr
0.0 ft
7.384 k
124.367 k
0.0 k-ft
24.072 k-ft
0.0 k-ft
8.281 k-ft
0.0 : 1
0.0 ft
0.0 k 0.0 k
Maximum Load Reactions ..
Top along X-X
Bottom along X-X
TopalongY-Y
Bottom along Y • Y
Maximum Load Deflections ...
Along Y-Y 0.0 in at
for load combination :
Along X-X 0.0 in at
for load combination :
0.0 k
0.0k
0.0 k
0.0k
0.0ft above base
0.0ft above base
Maximum Axial + Bending Stress Ratios Maximum Shear Ratios
...,L==oc:a=-d..:C-=-om=bi""n""ati""·o"-'n ________ ...cs.:...tre...;s.c..s_Rc;;_ati;..;,·o_-'Sc.:.tac.;.tu...cs __ Loca.:..:....:...;..c.lio.:...n _____ Sc._tress ~~tio Status Location _____ _
D Only · 0.058 PASS 0.00 ft 0.000 PASS 0.00 ft
+D+lr 0.059 PASS 0.00 ft 0.000 PASS 0.00 ft
+D-+0.750Lr 0.059 PASS 0.00 ft 0.000 PASS 0.00 ft
-+0.60D 0.035 PASS 0.00 ft 0.000 PASS 0.00 ft
· ~ Mailin'fi"'·;~_.gk,hf' ''1~;;r::. -F•:.:;' ::~:.:r:,,: ~'.rf::i"' · ', . : ..
Axial Reac.11on X-X Axis Reaction k
Load Combination @ Base @ Base @ Top
DO~ ~~
·+{}+lr 7.384
..0-+-0.750Lr 7.351
-+-0.600 4.352
y.y Axis Reaction
@Base @Top
Note: Only non-zero reactions are listed.
Mx -End Moments k•ft My -End Moments
@ Base @ Top @ Base @ Top
.L~Only _ -··, t .. ,.,, .. ,.... . ... . . 0.130 .
,. , .. §Jreme•_1!~~1C?.'1!1:&fal'li.;;;:T·~~-~-~·?~::t:::~~.:.:.·~:· --------------------.....,..-:----~-:--:----Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Mx -End Moments k•ft My -End Moments
Item
Axial@Base
Extreme Value @Base @Base @Top @Base @Top @Base @Top @ Base @Top
Maximum
Minimum
7.384
0.130
------------... --
0~ 3578 30th St
u•• ••c• . San Diego, CA 92104
619.236.0595
Project Title:
Engineer:
Project ID:
Project Descr:
:gxtrefue'B~iQns_ ,.{~-· • •1c?: ::;~7:1/c~i:L,;:tr;'? Axial R""e'"act;.;;i""on"""----'x'-.-x-Ax-ls_R_e_act_l_on--k--Y--Y-Ax_ls_R_eactl_on ___ Mx_-E_n_d_Mo_m-en-ts--k--ft--M-y-_E_n_d _Mo_m_e_n_ts-
ltem Extreme Value @Base @Base @ Top @ Base @ Top @ Base @Top @Base @Top
Reaction, X-X Axis Base Maximum 7.254 . Minimum 7.254
Reaction, Y-Y Axis Base Maximum 7.254
Minimum 7.254
Reacllon, X-X Axis Top Maximum 7.254
Minimum 7.254
Reaction, Y -Y Axis Top Maximum 7.254
Minimum 7.254
Moment, X-X Axis Base Maximum 7.254
Minimum 7.254
Moment, Y • Y Axis Base Maximum 7.254
Minimum 7.254
Moment X-X Axis Top Maximum 7.254 . Minimum 7.254
Moment, y.y Axis Top Maximum 7.254
Minimum 7.254
Maxlnitji ::. ~ ·, · ; 'J~1td~r t?o~"tomblnal1Qn'h#(\ ~: :-:_Ji~lf1,f
Load Combination Max. X-X Deflection Distance Max. Y • Y Deflection Distance .--,-~-,-----,,-=-,----...,-,,-=, D Only 0.0000 in 0.000 ft 0.000 in
-1{)-,{.r 0.0000 in 0.000 ft 0.000 In
0.000 ft
0.000 ft
-t0-+0.750Lr 0.0000 in 0.000 ft 0.000 in
-+0.60D 0.0000 in 0.000 ft 0.000 in
Lr Only 0.0000 in 0.000 ft 0.000 in
0.000 ft
0.000 ft
0.000 ft
:\\Steei: ·. ··::· f-n Pfd' . -HSS8x2x318
Depth =
Design Thick =
Width
I xx = 38.20 In•4
Sxx = 9.56 in•J
Rxx = 2.490 In
J = 12.100 in•4
Cw = 8.65 in"6
Wall Thick
Area
0.375 In Zx = 13.400 in•3
6.180 in•2 I yy 3.730 in•4 C = 8.650 ln•3
Weight 22.370 pit Syy = 3.730 ln•3
Ryy = 0.777 in
Zy 4.610 in•3
Ycg 0.000 in
••c .. r s San Diego, CA 92104 0~ 3578 30th St
·sl(et~es · ·' ,,.
619.236.0595
C: 0
C!
00
r--
! I
y
Project Title:
Engineer:
Project ID:
Project Descr:
JOB _______________ _
SHEETNO. ________ OF _____ _
CALCUI.ATEDBY _______ DATE ____ _
3578 30th street, San Diego, CA 92104 CHECKEDBV _______ DATE _____ _
SC~~--------------
t=cn"T I ;j C,.. (Ii:_) --0 IA,\. '. 4" ,0 1
'/... '.3 , 0 /
A s.t =-4 #. 1 i:-, -i:; .;:;; Ce,') (o. 10:) 1 ,'\ -z. ') ::. 4. o l ,t .i..
Oq --A~t ~ i:;·~~ '" rv 'J o,out·1 7 o.ovtt5
~SJ'.., _(:;.~~1,,,-.'.~~8'"~',1~G. .. Q 11:"'i.v Ct'Jj
--¼~ = ta -;;. 721 ,-4=~ _
~ C.... I 'Q)o f'
~ ¥,.I :::_1 J;.,1(,,.-($~ YI '. -4 \, ,3 I -::, \'2,,C) ~ /°4 • 6 s ~~ J'.'. I ·12,14i.:)
(~·, .... ____ ,,,._...~--·
✓
0 PFIOOUCT2f/1
Jerid Walters PROJECT: Mayesh
CLIENT: Mayesh
JOB NO.: DATE: 5/2612018
Joist Desi n Based on AISI S100/SI-10 & ICBO ER-4943P
INPUT DATA & DESIGN SUMMARY
SECTION & SPACING
JOIST SPAN
DEAD LOAD
LIVE LOAD
600S137-54 @ 24 in o.c
( 50 ksi)
L = 14 ft
DL = 15 psf
LL= 20 psf
LATERAL SUPPORTED? 1 compression flange
(0=No, 1 =compression flange, 2=tension flange)
DEFLECTION LIMITATION FOR LIVE LOAD?
(0=No., 1 = L /240, 2= L /360, 3= L /180, 4= L /120)
ANALYSIS
1 L /240
SECTION PROPERTIES OF EACH METAL STUD (SSMA page 7 & 8)
= 0.0566 in Fy 50 ksi
h = 6 in Wt = 1.75 lb/ft
A = 0.514 in2 rx 2.213 in
J = 0.000549 in4 Cw = 0.757 in8
CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI B1.2)
h / t = 106.01 < 200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3.1)
lxx
Sxx
ry
M,,IOi, = 27.23 in-kips > M [Satisfactory)
Where M = [(DL+LL) S +Wt.] L2 / 8 = 21.09 in-kips
S = 24 in o.c., spacing as given.
CHECK SHEAR CAPACITY (AISI C3.2)
V nlnv = 2708 lbs > V [Satisfactory]
Where V = [(DL+LL) S +Wt.] L / 2 = 502 lbs
CHECK LATERAL-TORSIONAL BUCKLING (AISI C3.1.2)
=
2.518
0.809
0.452
CASE 1: BOTH TOP & BOTTOM FLANGES UNSUPPORTED <== Does not apply.
Fe= Cbro-4 J<1ey<1/ = SJ
r0 = (r/ + r/ + x/)°-5 =
Si= 0.84
E= 29500
G= 11300
4.6 ksi < 2.78 Fy
< 0.56 Fy
2.398 in
in3 ,r2£
ksi (AISI pg xiv)
Uey
(Kyly lry{ ksi (AISI pg xvi)
PAGE 1 ·
DESIGN BY MPA
REVIEW BY
THE DESIGN IS ADEQUATE.
in4 Mr/Ob= 27.23 in-kips
in3 Vr/l1v= 2708 lbs
in Xo = -0.804 in
139.0 ksi
28.0 ksi
2.108 ksi
Ky= 1.0
K1= 1.0 1 [ ff
2£c l <11 = A2 GJ+----1 =
Ly= 168 in ro (K1L1}
4.743 ksi
Lt = 168 in
i
F y , for F e~2.78F e
JO IOFy Fe = -Fy(I---), for 2.7&>Fe~0.56Fe 9 36Fe
Fe , for F e~0.56F e
= 4.6 ksi
Jerid Walters PROJECT : MayeSh
CLIENT : Mayesh
PAGE 1
DESIGN BY MPA
JOB NO.: DATE: 5/2612018 REVIEW BY
Box Beam Design Based on AISI S100/$I-10 & ICBC ER-4943P
INPUT DA TA & DESIGN SUMMARY
VERT. MEMBERS 2
SPAN
(TOTAL SECTION: 4 x 6)
L=
X 600S200-43
10 ft
DEAD LOAD
LIVE LOAD
DL = 0.083 kips/ ft
LL= 0.11 kips/ft
COMPRESSION FLANGE SUPPORTED? (0=No, 1=Yes)
DEFLECTION LIMITATION FOR LIVE LOAD ?
•--H ' -I I II -H e.-11 I
I II I ~1 I 11-~,-II I
BEAM / HEADER. SECTION
1 compression flange supported
1 L /240
I II -11<
I 11 _lu
(0=No., 1= L/240, 2= L/360, 3= L/180, 4= L/120) THE DESIGN IS ADEQUATE.
ANALYSIS
SECTION PROPERTIES OF EACH STUD (SSMA page 7 & 8)
t = 0.0451 in Fy = 33 ksi 1)0( =
h = 6 in \/Vt = 1.67 lb/ft s"" =
A = 0.492 in2
rx = 2.335 in ry =
J = 0.000334 in4 Cw = 2.012 in6
CHECK MAX WEB DEPTH-TO-THICKNESS RATIO (AISI 81.2)
h /t = 133.04 < 200 [Satisfactory]
CHECK FLEXURAL CAPACITY (AISI C3. 1)
M,lnb • 2.87 ft-kips > M [Satisfactory]
Where M = (DL +LL+ Wt) L2 / 8 = 2.45 ft-kips
CHECK SHEAR CAPACITY (AISI C3.2)
V,lfly" 2.72 kips > V [Satisfactory]
Where V = (DL + LL + \/Vt ) L/ 2 = 0.98 kips
CHECK LATERAL-TORSIONAL BUCKLING (AISI C3.1.2.2) <== Does not apply.
Lu = 0.36Cb71' .JEGJ I y =
FySf
Where Cb= 1.0
1.24 ft < L
2.683
0.873
0.739
s,= 1.79 in3 (total vertical studs, SSMA page 7 & 8.)
E = 29500 ksi (AISI pg xiv)
G = 11300 ksi (AISI pg xvi)
in4
in3
in
ly = 2.701 in4 (neglecting top & bottom tracks conservatively.)
J = 0.001 in4
C b71' riir.",";-Fe = "EGJ I y = KylySJ
Where Ky=
Ly=
1.0
120 in
11.4 ksi
10 IOFy
!
Fy , for Fe';!.2.78Fy
Fe = 9 Fy(i-36FJ, for 2.?8>Fe';!.0.56Fy
Fe , for F eS.0.56F y
<
<
2.78 Fy =
0.56 Fy =
11.4 ksi
M,IOb=
Vnlnv =
Xo
91.7
18.5
=
17.24
1358
-1.468
ksi
ksi
in-kips
lbs
in
Mn/0:b• 1.01
Where Sc=
ft-kips
1.79
<Ji,= 1.67
< M [Satisfactory]
in3 (total vertical studs, SSMA page 7 & 8.)
Mn= ScFc = 20.30 in-kips
M = (DL + LL +Wr.) L2 /8 = 2.45 fl-kips
CHECK CAPACITY COMBINED BENDING & SHEAR AT ANY SAME SECTION (AISI C3.3.1) ( ~)\( ~v:r
Where M = 2.45
V = 0.98
V,./0., = 2.72
.{lb= 1.67
0.9275
ft-kips
kips
kips
< 1.0 [Satisfactory]
Mn= MIN( Bending , Buckling) = 4.80 ft-kips
Mr/Ob= 2.87 ft-kips, for bending only,
( ~) • 0.85
o{nt.')+(~)
CHECK DEFLECTION
5(ll)L4
/J.[L = 384£/
Technical References:
> 0.5 (~)
0.8739 < 1.3 [Satisfactory]
0.16 in < L /240 = 0.50
= 0.36 < 0.7
in {Satisfactory]
1. AISI 5100/Sl-10, North American Specification for the Design of Cold-fonned Steel Structural Members, with Supplement 1, 2010.
2. SSMA, Product Technical Information, ICBO ER-4943P, Steel Stud Manufactures Association, 2001.
(cont'd)
•
e .
'
OFFICE USE ONLY
RECORD ID# _________________ I
PLAN CHECK# ________________ I
Busi
Telephone#
e within the Cl of an
any o the items are ctrcled,
13. Corrosives
14. Other Health Hazards
15. None of These.
PART : E O O NTY P TME OF ENVR N NTAL HEALTH-H AR D : If the answer to any of the
questions Is yes, app icant must contact t e aunty of San 1ego azar ous Materials IvIsIon,
Call (858) 505-6700 prior to the issuance of a building pem,lt.
, San Diego, CA 92123.
0 CalARP Exempt
I FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy:
1. Is your business listed on the reverse side of this form? (check au that apply).
v
80
Es i (for new construction or remodeling projects) Date Initials
2. WIii your business dispose of Hazardous Substances or Medlcal Waste in any amount? 0 CalARP Required
I 3. Will your business store or handle Hazardous Substances in quantities greater than or equal to 55 gallons, 500
4.
5.
6.
7.
8.
□ □ □ □ □
pounds and/or 200 cubic feet? lid' WIii your business store or handle carcinogens/reproductive toxins in any quantity? 'i1' WHI your business use an existing or install an underground storage tank? S Will your business store or handle Regulated Substances (CalARP)? K WIH your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? W WH1 your business store petroleum In tanks or containers at your facility with a total facility storage capacity equal to
or realer than 1,320 aliens? California's Above round Petroleum Stora e Act .
Date lnltlels
0 CalARP Complete
I
Date lnltlals
p T 11: I O N R I N TRO DI T T AP D: Any YES* answer requires a stamp from APCD 10124 Old Grove Road, San
ego, C 3 d . ov ) 6-2650 . * o stamp required If 01 Yes D Q3 Yes mg Q4-Q6 No]. The following questions are Intended
to identify the majority of air pollution issues at the planning stage. Projects may require additional measures not Identified by these questions. For comprehensive
requirements contact APCD. Residences are typlcally exempt, except -those with more than one building• on the property; slngle buildlngs with more than four
dwelling units; townhomes; condos; mixed-commercial use; deliberate bums; residences forming part of a larger project. rExcludes garages & small outbuildings.]
1.
2.
3.
4.
5.
6.
YES NO
B lJ WIii the project disturb 160 square feet or more of existing building materials?
Wm any load supporting structural members be removed? Notification may be required 10 wolidng days prior to commencing demolition.
(ANSWER ONLY tF QUESTION 1 or 2 IS YES) Has an asbestos survey been performed by a Certified Asbestos Consultant or Site Surveillance
Technician? □ □
□
□
□
D (ANSWER ONLY JF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 1 O working days prior to commencing asbestos removal. 1M' WIii the project or associated construction equipment emit air contaminants? See the reverse side of this form or APCD factsheet <www sdaocd oralinto/factslpermits odf) for typical equipment requiring an APCD permit. D (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bounda
of my knowledge and belie
Sign of O er or Authorized Agent
FOR OFFICAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION
BY: DATE; I
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDINQ PERMIT l!IUT NOT FOR OCCUPANCV REI.USED FOR OCCUPANCY
COUNTY-HMO• APCD COUNTY-HMO APCD COUNTY-HMO APCD
. A stamp in this box 2!llil exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may sttll apply.
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
•
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
_/ / SCREENING SURVEY
Date P~~ (/e, L
Business Nam~ t:'.t-~ ,t¼,..,.,,,,,--df,.,,r;&e-r
Street Address /q. --!;:)./4~ ~ , ~ <£
Email Address lv~49~,-e=e1& ~ ,.,J 4
PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS)
Check all below that are present at your facility: □
Acid Cleaning Ink Manufacturing Nutritional Supplement/
Assembly Laboratory Vitamin Manufacturing
Automotive Repair Machining/ Milling Painting I Finishing
Battery Manufacturing Manufacturing Paint Manufacturing
Biofuel Manufacturing Membrane Manufacturing Personal Care Products
Blotech Laboratory (i.e. water filter membranes) Manufacturing
Bulk Chemical Storage Metal Casting/ Forming Pesticide Manufacturing /
Car Wash Metal Fabrication Packaging
Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing
Chemical Purification Electroplating (including precursors)
Dry Cleaning Electroless plating Porcelain Enameling
Electrical Component Anodizing Power Generation
Manufacturing Coating (i.e. phosphaling) Print Shop
Fertilizer Manufacturing Chemical Etching / Milling Research and Development
Film/ X-ray Processing Printed Circuit Board Rubber Manufacturing
Food Processing Manufacturing Semiconductor Manufacturing
Glass Manufacturing Metal Powders Forming Soap I Detergent Manufacturing
Industrial Laundry Waste Treatment I Storage
SIC Code(s) (if known): _____________________ _
Brief description of business activities (Production/ Manufacturing Operations): _____ _
Description of operations generating wastewater (discharged to sewer, hauled or evaporated):
Estimated volume al industrial wastewater to be discharged (gal/ day): -~N~A:~-----
List hazardous wastes generated (type I volume): __ _£.,,,,_ __________ _
Date operation began/or will begin at this location: p~/4 t;/19 :!:
Have you ap~d for a Wastewater Discharge Permit from the Encina Wastewater Authority?
Yes £blpl If yes, when: .
Site Contact /Z,-• A itle.-/4.....,U'-=-'---------
,~~@'~~:::_,,..:====a:_1phone No. tl-19 'f"U 'Z[J, 't'.
HORITY, 6200 Avenida Encinas Carlsbad, CA 92011 (760) 438-3941
FAX: (760) 476-9852
Revision Permit
Print Date: 01/14/2019
Job Address: 1969 Kellogg Ave
Permit Type: BLDG-Permit Revision Work Class: Commercial Permit Revi~
Parcel No: 2120921200 Lot#:
Valuation: $ 0.00 Reference#:
Occupancy Group: M Construction Type
# Dwelling Units: Bathrooms:
Bedrooms: Orig. Plan Check#: CB2018-0467
Plan Check#:
Project Title:
(city of
Carlsbad
Permit No: PREV2018-0284
Status: Closed -Finaled
Applied: 11/08/2018
Issued: 12/20/2018
Permit 01/14/2019 Fina led:
Inspector: PBurn
Final
Inspection:
Description: KELLOGG FLOWER MARKET: DEFERRED COOLER ROOM ELECTRICAL PLAN (1 SHEET)
Applicant: Owner:
DANNY TOUCHET TECHPLEX LP
1000 Pioneer Way
310-626-S650 EL CAJON, CA 92020
FEE
BUILDING PLAN CHECK REVISION ADMIN FEE
MANUAL BUILDING PLAN CHECK FEE
Total Fees: $ 363.12 Total Payments To Date : $ 363.12
Building Division
Balance Due:
AMOUNT
$35.00
$328.12
$0.00
1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
{ Cicyof
Carlsbad
PLAN CHECK REVISION OR
DEFERRED SUBMITTAL
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Original Plan Check NumberC:f:C2.D\£>-ct\(J)7 Plan Revision Number ~ZDIP:,-0204
Project Address \9,si9 \/,_ O\\o~°:J
General Scope of Revision/~ubmittal: __________________ _
Do tp rcoc), cao\e..c
CONTACT INFORMATION:
Name 0,,, ,,,. "' / \o c~, t\. Jt ., Phone
Address 2 d Lf I 2 N c:,£=.,:,c, d\\c' ½,.)e Zip
TYil+ .. \ I', . ' Email Address ~-Pl (2, cl ✓, <·-,, V\.. ( ~;:J v:Y'-:A 1 \ • Cd>""---
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 . Elements revised: D Plans D Calculations D Soils D Energy D Other
2. 3.
Describe revisions in detail List page(s) where each
revision is shown
Elo,D
4. Does this revision. in any way, alter the exterior of the project? D Yes 0 No
5. Does this revision add ANY new floor area(s)? D Yes D No
6. Does this revision affect any fire related issues? D Yes D No
7. Is this a complete set? D Yes D ~h
£S'Signature:::::I::::) ~ \ ? ~ Date Ncl)J ~> J I 1z>
1635 Faraday Avenue, Carlsbad, CA 92008 Ph: 760-602-2719 ~: 760-602-8558 Email: building@carlsbadca.gov
www.carlsbadca.gov
DATE: 12/14/2018
JURISDICTION: City of Carlsbad
✓• EsG1I
A SAFEbuilt Company
D ~PLICANT
-9""JURIS.
PLAN CHECK#.: CBC2018-0467.REV(PREV2018-0284) __ SET: II
PROJECT ADDRESS: 1969 Kellogg
PROJECT NAME: Kellogg Flower Market Cooler
lz;:J The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corr~cted plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
lz;:J EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacted:~. Telephone#:
Date contacted: . ( ) Email:
Mail Telephone Fax n Person
0 REMARKS:
By: David Yao
EsGil
Enclosures: approved plan
12/7/18
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: 11/20/2018
JURISDICTION: City of Carlsbad
✓• EsG1I
A SAFEbuilt'Company
□ APPLICANT
□ JURIS.
PLAN CHECK#.: CBC2018-0467.REV(PREV2018-0284) __ SET: I
PROJECT ADDRESS: 1969 Kellogg
PROJECT NAME: Kellogg Flower Market Cooler
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[8J The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[8J The applicant's copy of the check list has been sent to:
Danny Touchet
0 EsGil staff did not advise the applicant that the plan check has been completed.
[8J EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Danny Touchet
Date c · / -f g (by:/({?) Email:
Telephone#: 310-626-5650
dptelectricinc@gmail.com
By: David Yao
EsGil
Fa In Person
11/13/18
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
'City of Carlsbad CBC2018-0467.REV(PREV2018-0284)
11/20/2018
GENERAL PLAN CORRECTION LIST
JURISDICTION: City of Carlsbad
0467.REV(PREV2018-0284)
PROJECT ADDRESS: 1969 Kellogg
DATE PLAN RECEIVED BY
ESGIL: 11/13/18
REVIEWED BY: David Yao
FOREWORD (PLEASE READ):
PLAN CHECK#.: CBC2018-
DATE REVIEW COMPLETED:
11/20/2018
This plan review is limited to the technical requirements contained in the International Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and disabled access. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. The approval of
the plans does not permit the violation of any state, county or city law.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
□ Yes □ No
. City of Carlsbad CBC2018-0467.REV(PREV2018-0284)
11/20/2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
0467.REV(PREV2018-0284)
PLAN CHECK#.: CBC2018-
PREPARED BY: David Yao
BUILDING ADDRESS: 1969 Kellogg
BUILDING OCCUPANCY:
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
cooler
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurlsdictlon Code cb By Ordinance
Bldg. Permit Fee by Ordinance ~
Plan Check Fee by Ordinance • I
Type of Review: 0 Complete Review
0 Repetltlve Fee 3 Repeats
* Based on hourly rate
Comments:
0 Other
0 Hourly
EsGII Fee
DATE: 11/20/2018
Reg. VALUE
Mod.
0 Structural Only
l------=2::.:...5:..il Hrs. @ •
$105.00 _
($)
$262.SOI
Sheet of
' City of Carlsbad CBC2018-0467.REV(PREV2018-0284)
11/20/2018
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil and the Carlsbad Planning, Engineering and Fire
Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
1. Please provide structure support detail for the new evaporator coil.
2. Please provide lighting circuit design and updated panel schedules. Also update lighting
energy design and mandatory measures. CEC140.6
3. A, b switching no longer complies with the energy compliances measures.
4. Provide mechanical design for the evaporator coil condenser units to include condensate
drain system.
5. Provide energy compliance documents for the evaporator coil condenser unit shown.
6. The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite 208,
San Diego, California 92123; telephone number of 858/560-1468, to perform the plan
review for your project. If you have any questions regarding these plan review items,
please contact Morteza Beheshti at Esgil. Thank you.