HomeMy WebLinkAbout1971 MARCASITE PL; ; CB073041; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
04-17-200f! Residential Permit Permit No: CB073041
Job Address:
Permit Type:
Parcel No:
Valuation:
Building Inspection Request Line (760) 602-2725
1971 MARCASITE PL CBAD
RESDNTL Sub Type: SFD Status:
2132912100 Lot#: 49 Applied:
$314,169.24 Construction Type: Entered By:
ISSUED
12/11/2007
JMA
Occupancy Group:
04/17/2008
Reference #:
VN
CT04-09 Plan Approved:
# Dwelling Units:
Bedrooms:
Structure Type: SFD Issued: 04/17/2008
4 Bathrooms: 4 Inspect Area:
TRIESTE PL 2: PHS 5 2745SF LV, Orig PC#: PC 06-35 Project Title:
639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF PATIO Plan Check#: PC 07-75
Applicant:
WARMINGTON HOMES
701 PALOMAR AIRPORT RD
CARLSBAD CA 92011
931-4766
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$1,318.65
$0.00
$857.12
$0.00
($68.57)
$31.42
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$7,702.00
D1
$0.00
$0.00
Owner:
WARMINGTON TRIESTE ASSOCIATES LP
C/O WARMINGTON HOMES CALIFORNIA
3090 PULLMAN ST #A
COSTA MESA CA 92626
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $27,733.13 Total Payments To Date: $27,733.13 Balance Due:
$0.00
$225.00
$7,188.00
$3,618.63
$5,717.88
$0.00
$0.00
$0.00
$750.00
$0.00
$0.00
$259.00
$60.00
$74.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$27,733.13
$0.00
Inspector: flll. ~ Date: Clearance: ,>,,-':!,-of,
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fee:,/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3,32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
whi Tl h' i 1 n h
Inspection List
Permit#: CB073041 Type: RESDNTL SFD TRIESTE PL 2: PHS 5 2745SF LV,
639SF GAR/110SF DECK/138SF LOG/120S
Date Inspection Item lnsp~cto_r Act Comments
12/04/2008 89 Final Combo MC Fl OK TO RELASE GAS -FILL DATE TAGS
AT FIXTURES OK, NON METALLIC
PIPING DECAL AT PANEL OK
12/04/2008 89 Final Combo RI
10/24/2008 39 Final Electrical MC AP EMR only, ok to release meter
10/2212008 39 Final Electrical MC CA PER CONTRACTOR
0910512008 17 Interior Lath/Drywall PC AP
0812012008 17 Interior Lath/Drywall MC PA DRYWALL ONLY
08/2012008 18 Exterior Lath/Drywall MC AP
0812012008 23 Gas/Test/Repairs MC AP
0811312008 16 Insulation MC AP
0811212008 16 Insulation MC co COMPLETE ALL WORK
0810812008 14 Frame/Steel/Bolting/Weldin PC AP
0712512008 13 Shear Panels/HD's PD AP
0712312008 13 Shear Panels/HD's MC NR NEED EXT. FIREPLACE
0712112008 13 Shear Panels/HD's MC PA COMPLETE EXT. FIREPLACE
0710112008 15 Roof/Reroof MC AP
05127/2008 81 Underground Combo MC AP RECEIVED SOILS, PT & BLDG PLACE
REPORTS
0512312008 81 Underground Combo MC NS ROOL TO 5-27
0511512008 22 Sewer/Water Service MC AP FIRE SPRINKLER LINE OK
0511412008 21 Underground/Under Floor MC AP
0511412008 22 Sewer/Water Service MC PA NEED FIRE SPRINKLER LINE
Thursday, December 04, 2008 Page 1 of 1
City of Carlsbad Bldg Inspection Request
For: 12/04/2008
'"' Permit# CB073041 Inspector Assignment: MC
Title: TRIESTE PL 2: PHS 5 2745SF LV,
Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF
PATIO
Type: RESDNTL Sub Type: SFD
---
Phone: 7604271926
Job Address: 1971 MARCASITE PL
Suite: Lot: 49
Inspector: -~M_e, __ Location:
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
----··---·
Requested By: KYLE ISBELL
Entered By: CHRISTINE
Act Comments
.£L Ok'.,. j"b :g..§1.-t;.A~ hM,
t ~ PA-:$--f"A4~ Ar Fl'x'II-\~ or-,.
Nol\l-MEt"At..YL.. f"( PJ,,l.t::i t:>~At. AT PAN£1-o /£..
.;---
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lns(lection HistQ[l!
Date Description Act lnsp Comments
10/24/2008 39 Final Electrical AP MC EMR only, ok to release meter
10/22/2008 39 Final Electrical CA MC PER CONTRACTOR
09/05/2008 17 Interior Lath/Drywall AP PC
08/20/2008 17 Interior Lath/Drywall PA MC DRYWALL ONLY
08/20/2008 18 Exterior Lath/Drywall AP MC
08/20/2008 23 Gas/fest/Repairs AP MC
08/13/2008 16 Insulation AP MC
08/12/2008 16 Insulation co MC COMPLETE ALL WORK
08/08/2008 14 Frame/Steel/Bolting/Welding AP PC
07/25/2008 13 Shear Panels/HD's AP PD
07/23/2008 13 Shear Panels/HD's NR MC NEED EXT. FIREPLACE
07/21/2008 13 Shear Panels/HD's PA MC COMPLETE EXT. FIREPLACE
07/01/2008 15 Roof/Reroof AP MC
, CltJ DI Clrllbld
~ '; Flnal Bulldlll IISPICdOI -"'I'-· • DEC -1 2008
Dept: Buildi
Plan Check#:
Pia ning CMWD St Lite Fire
Date: 11/26/2008
Permit#: 41 Permit Type: RESDNTL
Project Name: TRIESTE PL 2: PHS 5 2745SF LV, Sub Type: SFD
639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103
Address:
Contact Person:
Sewer Dist:
1971 MARCASITE PL
Phone:
LC Water Dist: CA
Lot: 49
..........................................................................................................................................................
Inspected
~.$
Date t1f1s[d& By: f2oJ:& Inspected: Approved: )< Disapproved: __ I
Inspected Date
By: Inspected: Approved: Disapproved: __
In spected Date
By: Inspected: Approved: Disapproved: __ ...........................................................................................................................................................
Comments: ______________________________ _
' I
&EOCON ~o-o ·
\ 'Iii I• , ~EOT~HNICAL CONSULTANTS C'~ INCORPORATED
6960 FLANDERS DRIVE ■ SAN DIEGO, CALIFORNIA 92121-2974 ■ TEL (858) 558-6900 ■ FAX (858) 558-6159 .,
FOUNDATION OBSERVATION REPORT
PROJECT NAME: _7-'----~_C:=:i'--"-2--'e:""'E=-,._,----'-:,_•_..,_\N-'----'.,"--"-'-=-~""'--•c..:'-=l-.;_'-=o'-V:-"-----PROJECT NO. ow'k3 -S-2. -2~
LOCA TION : ---=L'-"'-r_, __ '-/_c;,_5_-_'-f-'---'1'-+-; ---"~"---',_,/_j::,.....::..&...;::5'" ____ _ DATE : __ s_-_2_1._._-_::i_'S ____ _
FOUNDATION LOCATION lif not entire building)
PLAN FILE NO. PERMIT NOS : '-/.5 ·. <-,., "' l} o !, t.,
1-11o : 73r'-/ •I
FOUNDATION TYPE : 'f7." 73.:;4 D
0 .faONVENTIONAL 1/ J ·. 7 3 ~ :'.> 7
Q"POST-TENSIONED tf 1: 73,:,•t I
6 s: 73 a '--/ □ ADDITIONAL OBSERVATION REQUIRED
~BST ANTIAL CONFORMANCE
• PURPOSE Of OBSERVATION (2. -b
Q'verify soil conditions exposed are similar to those anticipated MA C.A, ~ L W, ,_r &.---'
~erify footing excavations extend to minimum depth recommended in soil report
□ Verify foundation reinforcement complies with minimum recommended in soil report
□ '?rify slab reinforcement, sand bedding and moisture barrier comply with minimum .. recommended in soil report
~Verify footings have been extended to an appropriate bearing strata
D Other
e APPLICABLE SOIL REPORT : TITLE : l...J p, 0 A ·1 ~::. G C ~ ..... ,::-(: , B -, , -' V. ,_
;:_ "=-G & "'" ,.,. c-i s. /· , 7
• SOll:,,Rf PORT RECOMMENDATIONS BASED ON :
Q"Expansion Condition D VERY LOW
Ga"Fill Geometry v c. I c: ' '-'-
□ Other : G 1 I · 1~-'-I J ~ r
• MINIMUM FOUNDATION RECOMMENDATIONS:
~ow
-rL-. '-/ 5
/
@"'MEDIUM
l .. , · l 5 I
,;:,r. LA Le::.'$~~
DA TE : .3 -' ,.J -Cl Q
□ HIGH □ VERY HIGH
~ooting Depth : 5Yd4rfc~ ~ ~~~ □ 24 Inches OTHER ____________ _ rs ..
Footing Reinforcement: □ No.4 T&B □ 2-No.4 T&B □ 2-No.5 T&B Gr'Post-Tensioned OTHER : _____ _
Interior Slab Reinforcement : D 6x6-10/10 □ 6x6-6/6 D No.3@24Inches D No.3@18Inches B"Post-Tensioned
Slab Bedding Material and Thickness : ____________ Vapor Barrier :
Foundation Width : 1 ·.z · · ,,... r-.J
• OBSERVATIONS:
Gr"Substantial conformance with Soil Reports (see "Purpose of Observation")
~~bstantial conformance with Foundation Plans. Identify : I -r 1;;,-•~ J l3 'I 0., ~ •,· · · c ,.J
J,.t:;. :?...OCo-S
□ Otb~r.
,,. • COMME3 ------------------------------( ---,. ____ ,, __ -/;---------------
/ . \,_ __
TE: IT IS ASSUMED THAT All FOOTING EXCAVATIONS Will BE OEANED Of LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOil MOISTURE CONTENT Will BE MAINTAINED
FIELD COPIES TO · GEOCON REPRESENTATIVE
; .
l'IHY. lb.C:::1:::11:::Jt::t 'jl; 'f:>Hl'I J.',IHl'(l'l11'1bl Ul'1-0Hl'1 LJlt.~V NU.b\1(
.I
PLANNING
ENGINEERING
SURVEYING
HUNSAKER
&ASSOCIATES
S "' N D I t C Cl. l N (.
IRVINE
LOS AN CELE! May 14, 2008
RIVERSIDE
SAN Dl!CO
ARIZONA
OAVEHAMMAf\
LEX WILLIMAr,,I
ALISA VIALPANDO
DANS!,IITH
RAY M,\ICTIN
CHUCl(C/\TE~
!),a, WAplel Slfl!'itl
S,1n Oi1•,:n, CA 921.11
lflr,n) !i5ft-4J(I() IIH
mr;ni S!iA-1-114 F)(
www.Hun,~kNS0.et)tfl
•*wlHUll.(.lkrrSO.cnrn
City of Carlsbad
Engineering Department
1635 Faraday Avenue
Carlsbad, CA 92008-7314
Re: Building Form Certification
La Costa Greens Neighborhood 1. 17
Carlsbad Tract 04-09/PUD 04-08A
Drawing No. 429-2C
Lots 45 through 49 and 64 through 71
Dear City Inspector:
Please be advised the building foundation forms ;ire in conformance with the
precise grading plans as to horizontal and vertical location. All locations checked
were found to be within 0.1 of a foot horizontally and vertically per the precise
grading plans.
Sincerely,
Daniel P. Smith L.S. 6854
Hunsaker & Associates San Diego, Inc.
TK ~I i,.,\OlC712QQ~'c!2l CIOU
'"D 0101·~111 .llt,110110 11 I\M
';,.·
.,,..
'FIX PAGE
' .. 'D REINFORCED MASONRY . □ ~LDING .
' ., • 'I. ' '-;''• '\ '' ·~:·,•, ' '' I '
igJ P.T. CONCRETE l STRESS • D EPOX'( ANCHO~S D 'H.S. BOLTING ~ ' I.KJ 1 L,.p"~ , . ..
DSAAPP,NO.:
<f '-,i 111 ,~. II : ... !INf, 11-lC & .
n ~ ..:; ,,.
t) z "-UJ t
0 ,r,
Southern California Soil and Testing, Inc.
, 6.280 Riverdale Street, San Diego, CA 92120 (619) 280-4321
P.O. Box 600627, San Diego, CA 92160-0627
83-7 40 Citrus Avenue, Suite G, Indio, CA 92201-3438 (760) 77 5-5983
Concrete (4x8) Compressive Str e ngth Test Report
File Number : 061 2215
Project Title: Trieste at La Costa Greens PTCC Phase: 5
Project Location: rn11 Marcasite Pace
Architect: n/a
Engineer: Davidson Reinforcing Permit No: CB073091
Contractor: Warmington Plan File No:
Location In Structure: Lot: 49 Slab on Grade -Southeast Quad
Material Supplier: Superior
Mix Designation: 375p
Admixture(s): n/a
Time In Mixer:
Air Content: (ASTM C173/C231)
Air Temp:
Truck Number:
Samples Made By: (ASTM C31)
Laboratory Number
Mark On Samples
Date Made
Date Received
Date Tested
Diameter, Inches
Area, Square Inches
Maximum Load, Pounds
Compressive Strength, psi
Age Tested
Required 28 Day Strength, psi
Fracture Type
62 minutes
72 degrees F
010
CEN
0870532
LOT#49
5/28/2008
5/29/2008
6/2/2008
4.00
12.57
57020
4540
5 Days
4500
Slump inches: (ASTM C143)
Unit Weight Plastic/Dry, pcf: (ASTM
C138/C567)
Concrete Temp: (ASTM C1064)
Ticket Number:
Samples Tested By:
0870533 0870534
5/28/2008 5/28/2008
5/29/2008 5/29/2008
6/25/2008 6/25/2008
4.00 4.00
12.57 12.57
85300 85310
6790 6790
28 Days 28 Days
4500 4500
2 2
5.00
I
72 degrees F
116807
CN DH
Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable
ASTM C39 standards. This agency makes no other warranties express or implied.
Fracture Type: 1 -Reasonably well formed cones on both ends, less than 1 in. of cracking through caps; 2 -Well formed cone on
one end, vertical cracks running through caps.no well defined cone on other end; 3 -Columnar vertical cracking through both ends,
no well formed cones; 4 -Diagonal fracture with no cracking through ends; 5 -Side fracture at top or bottom (occur commonly with
unbonded caps); 6 -Similar to type 5 but end of cylinder is pointed.
Distribution:
(1) City of Carlsbad -Building Inspection Department
(1) Warmington Hornes California
Reviewed By: ~---~-~--
-Gordon T.M. W/odard RCE # 60481