HomeMy WebLinkAbout1975 MARCASITE PL; ; CB073037; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
04-17-2008 Residential Permit Permit No: CB073037
Job Address:
Permit Type:
Parcel No:
Valuation:
Building Inspection Request Line (760) 602-2725
1975 MARCASITE PL CBAD
RESDNTL Sub Type:
Lot#: 2132912000
$276,432.00 Construction Type:
SFD
48
VN
Status:
Applied:
Entered By:
ISSUED
12/11/2007
JMA
Occupancy Group:
04/17/2008
Reference#: CT 04-09 Plan Approved:
# Dwelling Units: 1 Structure Type: SFD Issued: 04/17/2008
Bedrooms: 3 Bathrooms: 2 Inspect Area:
TRIESTE PL 1: PHS 5 -2448SF LV Orig PC#: PC 06-35 Project Title:
474SF GAR/176SF DECK/173SF LOG/27SF PORCH Plan Check#: PC 07-75
Applicant:
WARMINGTON HOMES
701 PALOMAR AIRPORT RD
CARLSBAD CA 92011
931-4766
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot Water Con. Fee
Meter Size
Add'I Pot Water Con. Fee
Reel. Water Con. Fee
$1,190.97
$0.00
$774.13
$0.00
($61.93)
$27.64
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$7,702.00
D1
$0.00
$0.00
Owner:
WARMINGTON TRIESTE ASSOCIATES LP
C/O WARMINGTON HOMES CALIFORNIA
3090 PULLMAN ST #A
COSTA MESA CA 92626
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $26,800.00 Total Payments To Date: $26,800.00 Balance Due:
$0.00
$225.00
$7,188.00
$3,618.63
$5,031.06
$0.00
$0.00
$0.00
$750.00
$0.00
$0.00
$217.00
$70.00
$67.50
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$26,800.00
$0.00
Inspector: ylA. ~ FINAL APP~VAL
Date: 11-/ 0 <>~ Clearance: \:Z.:S-Oi,
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, c:r other exactions hereafter collectively
referred to as 'fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required irJormation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar -!lny subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
Ii r vi I
City of Carlsbad Bldg Inspection Request
For: 12/08/2008
Permit# CB073037 Inspector Assignment: MC ---
Title: TRIESTE PL 1: PHS 5 -2448SF LV
Description: 474SF GAR/176SF DECK/173SF LOG/27SF PORCH
Type: RESDNTL Sub Type: SFD Phone: 7604271926
Job Address: 1975 MARCASITE PL
Suite:
Location:
Lot: 48
Inspector: _ __,M,..__~ __
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES L P
Remarks:
Total Time:
CD Description
19 Final Structural
29
39
Final Plumbing
Final Electrical
49 Final Mechanical
Act Comments
Requested By: KYLE
Entered By: JANEAN
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lnsgection Histor~
Date Description Act lnsp Comments
10/24/2008 39 Final Electrical AP MC EMR only, ok to release meter
10/22/2008 39 Final Electrical CA MC PER CONTRACTOR
09/05/2008 17 Interior Lath/Drywall AP PC
08/19/2008 17 Interior Lath/Drywall PA MC DRYWALL ONLY
08/19/2008 18 Exterior Lath/Drywall AP MC
08/19/2008 23 Gas/Test/Repairs AP MC
08/12/2008 16 Insulation AP MC
08/07/2008 84 Rough Combo AP MC
07/25/2008 13 Shear Panels/HD's AP PD
07/21/2008 13 Shear Panels/HD's PA MC COMPLETE NAIL PLATES
06/27/2008 15 Roof/Reroof AP PC
05/27/2008 81 Underground Combo AP MC RECEIVED SOILS, PT & BLDG PLACEMENT REPORTS
05/23/2008 81 Underground Combo NS MC ROLL TO 5-27
City of Carlsbad Bldg Inspection Request
For: 10/24/2008
Permit# CB073037 Inspector Assignment: MC ---
Title: TRIESTE PL 1: PHS 5 ·2448SF LV
Description: 474SF GAR/176SF DECK/173SF LOG/27SF PORCH
Type: RESDNTL Sub Type: SFD
Phone: 7604271926
Job Address: 1975 MARCASITE PL
Suite:
Location:
Lot: 48
Inspector: _.._M~l __
APPLICANT WARMINGTON HOMES
Owner: WARMINGTON TRIESTE ASSOCIATES L P
Remarks:
Total Time:
CD
39
Description
Final Electrical
Act Comments
Requested By: KYLE
Entered By: JANEAN
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lnsgection Histo[Y
Date Description Act lnsp Comments
10/22/2008 39 Final Electrical CA MC PER CONTRACTOR
09/05/2008 17 Interior Lath/Drywall AP PC
08/19/2008 17 Interior Lath/Drywall PA MC DRYWALL ONLY
08/19/2008 18 Exterior Lath/Drywall AP MC
08/19/2008 23 Gas/TesVRepairs AP MC
08/12/2008 16 Insulation AP MC
08/07/2008 84 Rough Combo AP MC
07/25/2008 13 Shear Panels/HD's AP PD
07/21/2008 13 Shear Panels/HD's PA MC COMPLETE NAIL PLATES
06/27/2008 15 Roof/Reroof AP PC
05/27/2008 81 Underground Combo AP MC RECEIVED SOILS, PT & BLDG PLACEMENT REPORTS
05/23/2008 81 Underground Combo NS MC ROLL TO 5-27
05/14/2008 21 Underground/Under Floor AP MC
05/14/2008 22 Sewer/Water Service AP MC
05/13/2008 21 Underground/Under Floor NR MC PER CONTRACTOR AFTER STOP
05/12/2008 21 Underground/Under Floor PA MC WASTE ONLY
05/12/2008 22 Sewer/Water Service NR MC
~ CltJ DI Clrllbld m FIIII Bulldlng IDSPICIIDD
~---
0EC -1 2008
Dept: Building lanning CMWD St Lite Fire
Plan Check#:
Permit#:
Project Name:
Address:
Contact Person:
Sewer Dist:
P 07-75
CB073037
TRIESTE PL 1: PHS 5 -2448SF LV
474SF GAR/176SF DECK/173SF LOG/27SF PORCH
1975 MARCASITE PL
Phone:
LC Water Dist: CA
Date: 11/26/2008
Permit Type: RESDNTL
Sub Type: SFD
Lot: 48
··························································································································································
Inspected ~~ Date
H {1~-l c!> b k By: ~ d ~ Inspected : Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
Comments: _____________________________ _
. , GEOCON \-0 0 .
. GEO;EtHNICAL CONSULTANTS ~; , J,NCORPORATED ■ SAN DIEGO, CALIFORNIA 92121-297 4 ■ TEL 1858) 558-6900 ■ FAX 1858) 558-6159 -6960 FLANDERS DRIVE
FOUNDATION OBSERVATION REPORT
PROJECT NAME : --'-7_ ..... _~;c..._C:=--'--=,z"""e:.=-·"'=-:: ,._...,--=:._· __._W--'--"':,:__:"-=-~c;:::_.:...• ·,=.,,_,_ . .:...· ...:...-..::0:...· V-..,.__ ___ _ PROJECT NO. owih-,3 -S-;_ -21..
LOCATION : --~L-"_;_\ __ '-/--'-5_-__;'-f'---'-1_,;-=~-'-..___I ...;::.j -=t_S'"=------DATE : __ s;_-_2 _1._-_"'_S' ____ _
FOUNDATION LOCATION (if not entire building)
PLAN FILE NO. PERMIT NOS : '1.5 ', <.. 1,10 1 } ,, ~ (,,
FOUNDATION TYPE :
0 ;,dNVENTIONAL
Q' POST-TENSIONED
"/lo: -r-~o~/'-t
~-7.' 7 3c,'4 D
1/~·. 73¢~ 7
'ft 730 '! f
□ ADDITIONAL OBSERVATION REQUIRED
~BST ANTIAL CONFORMANCE
• PURPOSE OF OBSERVATION
~erify soil conditions exposed are similar to those anticipated
~erify footing excavations extend to minimum depth recommended in soil repor.-t --....__ ______ __
D Verify foundation reinforcement complies With minimum recommended in soil report
D ~rify slab reinforcement, sand bedding and moisture barrier comply with minimum.recommended in soil report
ifverify footings have been extended to an appropriate bearing strata
D Other --------------------------------------
• APPLICABLE SOIL REPORT : TITLE : _'-....J=-P_o_4_--,_~_--=G=c:'-~-..--____,""'.....,c""". "=-· --'(2,,.--"-'_-,'--'-. -=-''---'V._, .... -'--'-. __,9"'--t::..---=L..='---'~--==c.:..c-s:c..-._·~=----
-r;, ~ G (i'(:'Fc,iS, /. /7
• SOl~EPORT RECOMMENDATIONS BASED ON:
Q"Expansion Condition D VERY LOW
Ga"Fill Geometry \J l / c ' '--'--
□ Other : C • / · 1-/.6-i 7 ~ T--C[_.
• MINIMUM FOUNDATION RECOMMENDATIONS :
'-·15 ..
@"~EDIUM
6 ··/ -1., 5 I
DATE:
□ HIGH □ VERY HIGH
,/'_ c;..ir ::i:::. ~/. v:\T :re (21 Footing Depth : 5r12 inches Lid'~ Inches □ 24 Inches OTHER ____________ _
15 Footing Reinforcement: □ No.4 T&B □ 2-No.4 T&B □ 2-No.5 T&B Gr'Post-Tensioned OTHER: _____ _
Interior Slab Reinforcement : □ 6x6-10/10 □ 6x6-6/6 □ No.3@24Inches D No.3@18Inches C3"'Post-Tensioned
Slab Bedding Material and Thickness : ____________ Vapor Barrier :
Foundation Width : 1 -Z ·' ,.,... ,-J
• OBSERVATIONS :
[¥Substantial conformance with Soil Reports (see "Purpose of Observation") ,,.,
Q-""~bstantial conformance with Foundation Plans. Identify : --'''---r __ ,~_, .. _,_~_·:i __ f3_,_,__l_-'L'-. -_A_~_,,_;-_,._n_.J _____ _
J:t=.. 2....00-5
• COMM~---------------------------------
<:·· ·-' ..... ---···----/1 ----------------------------------------
I
. 1•--·-TE: IT IS ASSUMED THAT All FOOTING EXCAVATIONS Will BE OEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOIL MOISTURE CONTENT WILL BE MAINTAINED
l:f-· s s· 2-..
FIELD COPIES TO GEOCON REPRESENTATIVE
. ;
/'/HT• Jb. i:::;1::11::1ts -:,; 'f:>HJ'I WHKl'lll'll:, I UN-=:>HJ'i LJll:.l:JV
PLANNING
ENCINEERINC
SURVEYING
HUNSAKER
&ASSOCIATES
S A. N O I t. C 0. I N ('.,
IRVINE
LOS ANGELES May 14, 2008
RIVERSIDE
SAN DIECO
ARIZONA
City of Carlsbad
Engineering Department
1635 Faraday Avenue
Carlsbad, CA 92008-7314
Re: Building Form Certification
La Costa Greens Neighborhood 1. 17
Carlsbad Tract 04-09/PUD 04-DSA
Drawing No. 429-2C
Lots 45 through 49 and 64 through 71
Dear City Inspector:
NU.bl1f
Please be advised the building foundation forms ;ire in conformance with the
precise grading plans as to horizontal and vertical location. All locations checked
were found to be within 0.1 of a foot horizontally and vertically per the precise
grading plans.
0/\VEHAMMAR
LEX WllLIM/\N
ALIS/\ VIALPANDO
DAN 51,\ITH
RAY MARTIN
CHUCl(C/\.TER
!>,o, w.aplu S1te-1!1
S,iriDic•~n,CA 92121
1/ViRl !i!ifl.-,l;iOO 1111
11\~nl 5!ill-1-114 F )(
www.Huns.1lct!rSD.com
hl(n@HU1tMk,rSO.com
Sincerely,
a.~
Daniel P. Smith L.S. 6854
Hunsaker & Associates San Diego, Inc.
Tk ~( ~.\01D~00~'oll OOG•
-~ ~IOf·JIII .11412001 10 fl A.M
.FIX PAGE /
D REINFORCED MASONRY ['.) 'WELDING D FIREPROOFING ,, '' ','f ~ Rl ,c<?~CRE:e i srRES~\-,, O ~POXV.ANCH,ORS D H.s, BOLTING
I .'':' ,DSA FILE NO,:'· ' ' ·; ' ··,0\ \,. I•. / l! .f
QSAAPP. NO.:
PlAN FILE NO,:
~,
Southern California Soil and Testing, Inc.
6280 Riverdale Street, San Diego, CA 92120 (619) 280-4321
P.O. Box 600627, San Diego, CA 92160-0627
83-740 Citrus Avenue, Suite G, Indio, CA 92201 -3438 (760)775-5983
Concrete (4x8) Compressive Strength Test Report
File Number: 0612215
Project Title: Trieste at La Costa Greens PTCC Phase : 5
Project Location: 775 Ma[casite Place
Architect: n/a
Engineer:
Contractor:
Davidson Reinforcing
Warmington
Permit No:
Plan File No:
Location In Structure: Lot: 48 Slab on Grade -Northwest Quad
Material Supplier: Superior
Mix Designation: 375p
Admixture(s): n/a
Time In Mixer:
Air Content: (ASTM C173/C231)
Air Temp:
Truck Number:
Samples Made By: (ASTM C31)
Laboratory Number
Mark On Samples
Date Made
Date Received
Date Tested
Diameter, Inches
Area, Square Inches
Maximum l oad, Pounds
Compressive Strength, psi
Age Tested
Required 28 Day Strength, psi
Fracture Type
84 mintues
70 degrees F
672
CEN
0870529
LOT #48
5/28/2008
5/29/2008
6/2/2008
4.00
12.57
56670
4510
5 Days
4500
Slump inches: (ASTM C143)
Unit Weight Plastic/Dry, pcf: (ASTM
C138/C567)
Concrete Temp: (ASTM C1064)
Ticket Number:
Samples Tested By:
0870530 0870531
5/28/2008 5/28/2008
5/29/2008 5/29/2008
6/25/2008 6/25/2008
4.00 4.00
12.57 12.57
81490 83840
6490 6670
28 Days 28 Days
4500 4500
1 1
CB073037
4.00
I
72 degrees F
116774
CN DH
Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable
ASTM C39 standards. This agency makes no other warranties express or implied.
Fracture Type: 1 -Reasonably well formed cones on both ends, less than 1 in. of cracking through caps; 2 -Well formed cone on
one end, vertical cracks running through caps.no well defined cone on other end; 3 -Columnar vertical cracking through both ends,
no well formed cones; 4 -Diagonal fracture with no cracking through ends; 5 -Side fracture at top or bottom (occur commonly with
unbonded ca ps); 6 -Similar to type 5 but end of cylinder is pointed.
Distribution:
(1) City of Carlsbad -Building Inspection Department
(1) Warmington Homes California
Reviewed By : / _,,, --------,--
,----I
Gordon T.M. Woodard RCE # 60481