HomeMy WebLinkAbout1979 PALOMAR OAKS WAY; ; CB071434; PermitfV.__•.V __) City of Carlsbad V 1635 Faraday Av Carlsbad, CA 92008 07-02-2007 Commercial/Industrial Permit Permit No: Building Inspection Request Line (760) 602-2725 Job Address: - 1979 PALOMAR OAKS WY CBAD Permit Type: TI Sub Type: INDUSTV Parcel No: 2130922100 V Lot #: 0 Status: Valuation: V $82297.00 Construction Type: V VN V Applied: Occupancy Group: V Reference # Entered By: Project Title: AIR PRODUCTS-CONVERT 1751- SF Plan Approved: WRHOUSE TO. CHEMICAL STORAGE Issued: Inspect Area: V V . Plan Check#: Applicant: AIR PROD,UCTS&CHEMICALS INC AIR PRODUCTS&CHEMICALS INC V 1969 PALOMAR OAKS WAY 1969 ALOAR OAKS CARLSBAD CA 92011 V / '" r... CARLSBADC'A 92011') V - V .4R1i S .i Mfr i, . V / '-$17.28 -- PFF(3105540),.,/ \ I $0.00 / $0.00 ' SDCWA Fee \ 's_-9 $0.00-'...- / $312.72 ., ,MeterFee \ \O ,—' V $0.00 ' $0.00 .. PF(4305540) \ c-" $0.00 $0.00,,' Addi Red Water Con FeeC' \ $0.00 $0.00— CFD Payoff Fee _-.y \ . \ $0.00 License Tax (3104193) $0.00 License Tax (4304193) /'f CJ) $0.00 ,.$0.00 ,Traffic lmpact Fee (310554 1)1 V \.J $0.00 $0.00 Traffic impact Fee (430554 Y1 $0.00 1$0.00 PLUMBINGTOTAL'\\-. I $0.00 \ S J$0.00 . ELECTRICAL TOTAL I / $35.00 $0.00. - MECHANICAL. j I $28.00 $0 00 Mater Drainage Fee - I / $0.00 Sew'erFe I $0.00 $0.00 Redev Parking Fee / $0.00 \. $O OOIGC' Additional Fees ;/ / $0.00 V HMP Fee \ ,j / ?? TOTAL PERMIT FEES V '. / $874.11 '"J 'I• '/! •' $874.11 Total Payment To Date: -") ) $87411'"' Balanóe Due: Total Fees V BUR -DING DG PLANS V V STORA V V . ___ATTACHED V , FINAL APPROVAL . . Inspector ($" Date Clearance NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively' referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your rtght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to v'hich the statute'óf limitations has previously otherwise expired. Building Permit Add'l Building Permit Fee Plan Check V / Add'l Plan Check Fee Plan Check Discount V Strong Motion Fee / Park Fee LFMFee A rm Bridge Fee BTD#2 Fee BTD#3 Fee Renewal Fee AddI Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size V AddI Pot. Water Con. Fee Red. Water Con. Fee $0.00 V V - , FOR OFFICE USE-0 Y - PERMIT.APPLATIbN PLAN CHECK NO. 7/3 'CITYOCARLSBADBUILDINGIDEPARTMENT ' EST. VA F 2075 Las paimad Dr, CarIsbad A 92009 - Plan Ck Deposit ,(760)438-1161 By- / ;v:3Date - . - PJE ..Ok(" J'.(:1CA. LbI I A-ir& 'PobcrS , Address (include Bldg/Suite #)_ * — - _._ - -. • - - - Business Name (at this address) - 4 -- . -; ,•, ,,,••• - r ':. Legal Description - , - Lot No - Subdivision Name/Number - - Unit No. ' Phase No. Total # of units'- OCIZ.S_ . •*. 1_l.2 L47••1 Lt• '4 Assessor's Parcel# ?) SF. Existing Use - -- - Propo ed Use --• .4 . - C ONVQIL7 l.s7,N&.) A .s- t-cr7EH Oj.C - 1Ir" i - l-13J/.4-, FL4t..,t AL L, .s TAC-, .rZot-i 'Description of Work-- - —" ( - - '- -SO. FT. -- -- - - #of Stories - --" - .-r- '# of Bedrooms ........# of Bathrooms -fl -*- 4. . , - . 4414 . :..-_- • . . I* . .4 " -' ..i •1 - - if ',..i :zr Cc'e 4ceL€ii I'\ (c r- Zkkç tM -P- I i1 13,1-7I j Name . - -I . - Address- - -. ----------' City - - - -'fl State/Zip - Telephone #- - Fax #- cANfD Contractor JD fcontractqO9r _fdi .' . • •- - . - - . .. • ., - • 'Name - - - - - - -- -Address -- - . -City - --r State/Zip - -- Telephone # 1 PROPERTOWJER Cso CA ?Zd!fl 74o 92'?4 2.5 1.. Name - , Address -J City , • .State/Zip Telephone # ONTRACTOR-..COMPANYNAML .(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to Construct, alter, impro'è, ddinolish or eailr 'ary s'tructure', prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law. 1[Chapter -9, commending, with Section 7000 of Division3 of the Business and Professions Code] or.that he'is exempt theiefrom, and the basis for the alleg'd exemption Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001) \ Name I - - - .r:,. .' .'- Address-' .. ' - I City .ri:. -.- ' State/Zip . .Telephone # ' -. , - & .................. _1 - • - -• . t- ' - •. - , e State License #' - . License Class CityBusiness License # - .. - .. Designer Name Address City , State/Zip ' Telephone - State License #' I - t - , • - - ' . I.- -. - • - - . I' 'Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: - -•-. ' I.. •i- - . ., -0 -1 have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance - of the work for which this permit is issued. ,.._P.- "Ji, 0 I have and will maintain workers' compensation; as required by Section 3700 of the-Labor Code; for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: , , . - • ,. . i . Insurance Company • • . Policy No. - - - Expiration Date - • - -. - (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) - -. - - - - -- ------ - E] - CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is -issiied, I shall not eplyany' person in any rn'nicerso as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation - coverage is unlawful, and shall subject an employer to criminal póna1tie and civil fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees SIGNATURE - DATE.-.--' F7 -v-- -''- _-__----'-----'- ---___•-- -'-'_'_- -----. -'----------• -- 0 N .1_•_ -_.—.----.----.------------.-.---- ----_.- _.--------.-----._-_'--'_----'---------- --_- / I hereby affirm that I am exempt from the Contractor's License Law for the following reason: g. I ,O I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale I (Sec. .7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does . ,such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). ( 1, as owner of the property, am exclusively contracting with licensed contractors to construct the !project(Sec. 7044, Business and'Presions CodrThe - Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects ,with contractor(s) licensed pursuant to the Contractor's License Law). - __ - - - - . - . _ - - - '' -- .. '• )__ -- lam exempt under Section Business and Professions Code for this reason: I personally plan to provide the major labor and materials for construction of the proposed property improvement 0 YES JO- -- ld/havenot)'signed an application f07a building permit for-the proposed work. '3.- I have contracted with the following person (firm) to provide tile proposed construction (include name / ?ddress / phone number / contractors licensenumber): f. -Vc. r _L C 4, I',Ian to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address / phone4' number / contractors license number):- ', '- I -. * 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phc?he number / types, \ of work): - -- .. - -'- ,, " .-- - -- " .-- - - - - - . . • -. - .. cç RTYOWR SIGNATURE s:2 I i LOMLETE THIS SECTION FOR NON JTIALBUILDINGPRIISNLX '1.... . .. Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or-risk management and prevention i program under Sections 25505,'25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES -0 NO -- ' ,Is the applicant or future building occupant reqtiireci'to obtain 'permit from ,the air pollution control district or irquaIity management district? 0 YES _D NO Is the facility to be constructed within 1;000 feet of the outer boundary of a school site? 0 YES 0 NO . * ..'' -'- - - r, - - - - '- IF ANY OF THE ANSWERS ARE YES!A. M FINALCERTIFICATE OF OCCUPANCY AY, NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETIN - G THE' REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. -'-'-'- - [CONSTRUCTIONtENDING AGENCY - _ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). - - -, -- .-- ,, .'* - -• I' - -' . * - . - 4 LENDER'S NAME LENDER'S ADDRESS - - - - - APPLIcANT.cERTIFIcATION . I certify that I hav4 read the appIiationd stat'that the above information iscorrect and that the infdmation ri the pleni is adciiratef I agreelt"o comply Wj -it h at ç ,,City ordinances and State laws relating to building construction. I hereby authorize representatives of the -Cit' of Carlsbad to' enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST--ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. - - . -. ,.i .'-'- ) - .-. . 4 - •_t . - --s. .•, -.' . '- 1- • ' )' - OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION: 'Every permit issued by the Building Official' under 'the provisions of this Code shall expire by limitation and become- null and void if the building or work authorized by such permit is not co nced within 365 days o the date f such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work commenced for a perio ay tion 106.4.4 Uniform Building Code).- APPLICANT'S SIGNATURE - - £_-- ' DATE - - WHITE: File - YELLOW: Applicant - PINK: Finance City of Carlsbad. 'Bldg Inspection 'Request For: 08/06/2007 ' Permit# CB071434 , ' ' Inspector Assignment: RB Title: AIR PRODUCTS-CONVERT 1751 SF , Description: WRHOUSE TO CHEMICAL STORAGE Type: TI ' ' SubType: INDUST Phone:, 7609296251 Job Address: , 1979 PALOMAR OAKS WY Suite: , Lot 0 Location: , ' ' : ' ' Inspector:' . APPLICANT AIR PRODUCTS&CHEMICALS INC Owner:' AIR PRODUCTS&CHEMICALS INC Remarks: Total Time: , ".' Requested By,: CRAIG Entered By JANEAN CD Description ,' ' Act omment. ' '•, . . . ' ' .19 'Final Structural . I4( ' 'rc5 29 Final Plumbing 39 Final Electrical .49 Final Mechanical Comments/Notices/Holds Associated_PCRs/CVs , Original' PC# Inspection History Date '. . Description ' Act lnsp Commnts 07/31/2007 . 14 Frame/Steel/Bolting/Welding ' AP RB 07/31/2007 24 Rough/Topout ' AP RB 07/31/2007 34 Rough Electric " ' 'PA RB MISSING GRND. ELECTRODE CONDUCTOR 07/31/2007 44 Rough/Ducts/Dampers .AP' 'RB 07/12/2007 . 24 Rough/Topout. "Afl MC O ' 07/09/2007 12 Steel/Bond Beam . ' AP RB © TRENCH DRAIN " 07/06)2007 11 Ftg/Foundation/Piers CO ' 'RB SEE NOTICE' 07/06/2007 ' 12 Steel/Bond Beam ' CO R Cliv of Carlsbad 0~ Final BuildiNg INspection RMv, Dept: Building Engineering Planning. CMWD St Lit 6,,~* Plan Check #: - Date: 08/06/2007 Perm it#: C8071434 Permit Type: TI = Project Name: AIR PRObUCTS-CONVERT 1751 SF Sub Type: INDUST WRHOUSE TO CHEMICAL STORAGE - Address: 1979 PALOMAR OAKS WY Lot: 0 Contact Person: £RAIG - Phone: 7609296251 Sewer Dist: CA Water Dist: CA Inspected Date - By: Inspected:, ~//d /67 Ap'rdved: Disapproved:'____ Inspected Date By: Inspected: Approved:. Disapproved: Inspected .-. •, Date By: - Inspëctèd: Approved: Disapproved: Comments: S - • - - - •0 - - JO •• - -. 0 0 -. -. - r * CONSTRUCTIONTESTING&ENGINEE R"ING* INC. ESCONDIDO • TRACY • RIVERSIDE • OXNARD • LANCASTER • SACRAMENTO INSPECTION REPORT PAGE ± OF CTE JOB # /-trt/ REPORT# PROJECT NAME: Aff(r,zoP(tC 7$ ADDRESS: eA7eLs&tp ARCHITECT: • /(LO4/' ENGINEER: CONTRACTOR: INSPECTION DATE: ~?z PLAN FILE: BLDG. PERMIT: OTHER: - .. . ••.• S -- - INSPECTION -MATERIAL IDENTIFICATION S. . , .. •,' feONCRETE S• .. CONCMIX#/PSI • - A , , - 4GROUTMIX/PSI k ''' ";. • S.. - . •. - • 'y MORTAR TYPE/PSI - ti., *..- ' ••.. . - - )FIELDWELDf ' •-.S .,. V. REBARGRADE4/c _'(6'__ ( ) SHOP WELDING ' STRSTEEL_____. ç)5PILE DRIViNG • - S -. • -S - S •- • S . .' H S BOLT___-' • • •: •. . - . - (5,) BATCH-PLANTS : > • - 'S S•S S' () EXP.ANCHOR. . MAS. BLOCK . j OTIR ELECTRODE ______________________.)' MATERIAL SAMPLING ()CONCRETE ()MORTAR ().GROUT ) FIREPROOF1NG ()MASONRY BLOCK ()REBAR ()STRUCTURAL STEEL ()BOLTS o M-' FZ'a f72,Je// PJ(-',ti 7'/2LDk7 Jto'i/ oF 947€ Ar AJEJ ?cF?iV6 /Z, PWA), 1Z'73,qg C 7,2Z6 r i2 p/ Certufucationif Compliance All wk nls otlerwisnoied compluwith th&'approved lans and, s'ecificat,ons and1 the'unifodibuuldungcTd4____ c$•_ NAME: (PRINT) /Ve7C 7ksT7JJ/3D SIGNATURE CERTIFICATION NO: C)Y/cc / 9.?o$?? GEOTECHNICAL & CONSTRUCTION ENGINEERING TESTING & INSPECTION 1441 MONTIEL ROAD, SUITE 115, ESCONDIDO, CA 92026 (760) 746-4955 FAX (760) 746-9806 EsGil Corporation 1 In 'Partnership with Government for Bui&fing Safety DATE: 6/28/07 U AP NT JURIS. JURISDICTION: City of Carlsbad U PLAN REVIEWER . . U FILE. PLAN CHECK NO.: 071434 SET: II . . PROJECT ADDRESS: i979-Palomar Oaks Way . PROJECT NAME: Air Products Hazardous Material Storage The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 El The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LIII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. LII The check list transmitted herewith is fo your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LII The applicant's copy of the check list is enclosed for the jurisdiction toforward to the applithnt contact person. LII The applicant's copy of-the check list has been sent to: . Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed., -. •Person contacted: Telephone #: Date contacted:. (by: , ) - Fax #: - Mail Telephone Fax In Person LII REMARKS: ' BY: David Yao . Enclosures: . •' ' - Esgil Corporation • - - El GA El MB -El EJ El PC 6/20 -' - 9320 Chesapeake Drive, Suite 208 • San Diego, Califorijia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In cpartnersscip with Government for tBui&fing Safety DATE: 6/5/07 LI LICANT JURIS. JURISDICTION: City of-Carlsbad LI PLAN REVIEWER LI FILE PLAN CHECK NO.: 071434 SET: I : PROJECT ADDRESS: 1979 Palomar Oaks Way PROJECT NAME: Air Products Hazardous Materials Storage The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. LI The plans transmitted herewith will substantially comply with the jurisdic's büildihgcodes when minor deficiencies identified below are resolved and checked by building department staff. LII The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: N. Craig Stephens LII Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: N. Praig Stephens Telephone #: 760-929-6251 Date contacted4/€/'O l(by4 ) Fax #: 760-931-7819 Mail Telephone V,4ax fr4fl Person r El REMARKS: : By: David Yao Enclosures: Esgil Corporation GA N MB LI ES LI Pc 5/29 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Car1sbd 071434 615107 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO.: 071434 .• 'JURISDICTION: City of Carlsbad OCCUPANCY: H-2/H-7 . USE: hazardbus material storage ,. TYPE OF CONSTRUCTION V-N ACTUAL AREA 1751 sf ALLOWABLE FLOOR AREA:. see plan ,'STORIES: 1— HEIGHT: SPRINKLERS?: 'Y '. '. OCCUPANT LOAD: REMARKS:. DATE PLANS RECEIVED, BY ' ' DATE PLANS RECEIVED BY JURISDICTION ESGIL CORPORATION 5/29 DATE INITIAL PLAN REVIEW ' '• .' 'PLAN.REVlEWER: David Yao COMPLETED: 6/5/07 FOREWORD (PLEASE READ) This plan review is limited to the technical require'merits cdntained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical'COde, National Electrical Code and. statd laws regulating energy conservation, noise attenuation and access for the disabled. This plan 'review is based on regulations enforced by the Building Department. You may have other corrections based on laws 6nd ordinances enforced by the Planning Department, Engineering' Department, * ' Fire Department or 'other departments. Clearance from those departments may' be required prior to the issuance of a building permit.' ,. . Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC The following items listed need clarification, modification or change. All items must be satisfied before the plans will be'in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uhiform Building Code, the approval of the plans does not permit tIie viblation of any state, -county or city law. ' ' . • , . To speed up, the recheck process, please 'note on this list (or a copy) where each correction item has 'been addressed, i.e., plan sheet number, specification 'sêctioñ, etc. Be sure to enclose the marked up list when ybu submit the revised plans. '' . City of Carlsbad 071434 6/5/07 •. . * . Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for ëOthmërcial/industriâl projects (two sets of plans for residential projects). For expeditious processing, corrected sets cn be submitted in one of'two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of 'Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320, ' '.' Chesapeake Drive, Suite 208, San Diego, CA92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to,their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until,review by EsGil Corporation is complete. ' " •' ' ' . ' - 'PLANS. Provide a note with the building data legend stating that yards used for area increases shall be permanently maintained. Provide a statement on the Title Sheet of the plans, stating that this project shall comply with the 2001 editions of the:California Building/Plumbing/Mechanical Codes and the 2004 edition of the California, Electrical Code, which adopt the 1997 UBC. 2000 UMC. 2000 UPC and the 2002 NEC. EXITS Exit doors from Group H-3, H-7 occupancies shall not be.provided with a latch or lOck unless it is panic hardware. Section 1007.- Exit doors should, be a minimum size of 3 feet by 6 feet ,8 inches. Maximum leaf width is 4 feet. Sections 1003.3.1.3 and 1003.3.1.4. Regardless of dccupant load, ,a floor Or landing not more than 1 inch (1/2-inch if , • disabled access is required) below the threshold is required on each side of an ' exit door. Section'1003.3.1.6.' • '- '. . ' EXIT SIGNS • . 6. Exit signs are required whenever two exits are required. Show' all required -exit ' . sign locations. Section 1003.2.8.2. . • ' , • :' 7. If exit signs are required, provide the following notes on' the plans, per Section 1003.2-.8.2: . • ' • t • . - !., City of Carlsbad 071434 11, .6/5/07 . •' '.' ' . . . a) 'Exit signs shall be located as necessary to clearly indicate the direction of egress travel. No point shall be more'than 100 feet from the nearest'. visible sign b). Exit signs shall be readily visible from any direction of approach. 8 Show two sources of power for the lamps at exit signs Section 1003.,2.8';5._' . ROOFS 9 A Class B roof covering is required Table 15-A (since the occupancy revised from S-i to H3/H7, the roof covering shall be B mm) . '• .. .. TITLE 24 DISABLED ACCESS 10. Provide notes 'and details on the plans to shofcornpIian'ce with the enclosed Disabled Access Review List. Disabled access requirements may be more restrictive than the UBC. ADDITIONAL Please refer to the following corrections for mechanical, plumbing, electrical and energy items. Storage Rack (Rack Design & Engineering Co) Obtain Fire Department approva.1 for groups F,: M and S occupancy storage per ,UBC Sections .306.8,'3019-.8 and 311.8. ' 13. Indicate the cibarance from the new racks to the existing building walls and building columns. 14. Sheet 3 of the calculation shows the thickness of the column wall shall be, .09". The plan (S3.0) shows .075". Please revise the plan.' ' " • 15.. Recheck all cOnnections on sheet S3.0 as follows' " •' " '. .• a) , The rivet bearing capacity is only dtF' = 0.406(0.0747)65 = 2'kips. ' ' ", ' • •b) Provide, calculations for all beam to bracket weld capacities per Section 2330 (allowable weld stress is the member thickness times 26 ksi times .1.33, or the weld stress, whichever is lower). ' • •: c) Check the bracket maximum weak axis moment. ' • , 16. Provide calculations. for the column weak axis bending plus, axial for transverse 'seismic loading. The axial load is the maximum compression load at the' base' ' • • • ' • from vertical plus seismic overturning. The column moment will probably be "• • maximum for the lateral load from the base plate to the first diagonal brace (not' only to the first horizontal member). . •' '• ' . • '. '' City of Carlsbad 071434 6/5/07 17 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc Please ihdicaté here 'if any changes, have been made to the plans that are not a result ofcórrections from this' list. If there are other changes, please briefly describe them and where they, are located in the plans.. .. Have changes been made to the plans not resulting from this dorrectionlist?. Please indicate U. Yes U No The jurisdiction has contracted with Esgil 'Corporation located at 9320 " Chesapeake Drive, Suite, 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review'for your project. If you have any . questions' regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. , ELECTRICAL PLAN REVIEW, 2002 NEC',. . PLAN REVIEWER Morteza Beheshtu .1. 'Please change all' references the NEC code cycle date to 2002. 2.' , Show the available fault current from the serving utility cO. and at the equipment where fault currentexceeds 10,000 amps: .. . . Show the ampere interrupting capacity (AIC) ratings of the service and sub- service equipment. NEC 110.9 Show or note on the plans the method Usedto' limit fault currents to 10,000 amps or lower on branch circuits Please provide a panel schedule for panel "EP4".. ' Plea's.e specify'the motor disconnect(s) shown on the single line. ' 'Please complete the electrical design per a. completed hazardous materials handling (once completed) report. Include the classification of areas and wiring methods with equipment ratings City of Carlsbad 071434 6/5107 8 Show on the plan the location of the service(s) NEC 110.261 230.2. 9; If utilizing a series-rated system, note on plans: "Overcurrent device enclosures will be identified as series-rated and labeled in accordance with NEC 110-22" and 'The overcurrent devices shall be AIC rated per, manufacturers labeling of the electrical equipment" . ENERGY CONSERVATION 10 The envelope designer, mechanical engineer and the author must sign the imprinted ENV-1-C forms Note If you have any questions regarding this Electrical or Energy plan review list please contact Morteza Beheshti at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans PLUMBING AND MECHANICAL, CORRECTIONS PLAIN REVIEWER: Glen Adamek 1. - Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes, before the permits are issued Business and Professions Code The final set of corrected drawings to be reviewed for signing and sealing just before the permits are to be issued 2 Please provide complete corrected hazardous material technical opinion and report as addressed in UBC, Section 307.1.6. Provide data on proposed hazardous material to be stored and used UBC Section 307 and UFC The Hazardous Materials Report by Klausbruckner & Associates does not list the amounts of each of the hazardous materials to be used and/or stored within the• building Also, the Disclaimer in the report clearly shows it "shall not to be used for the purpose of construction for this project". Please provide the complete corrected report to be used for the design and construction of this project Clearly show the types of hazardous material that are being stored or used, as per the UBC, Table 3-D and 3-E classifications Provide the material safety data sheets (MSDS) Clearly show the amounts of each type of hazardous material to be stored and in use. Clearly show where in the buildings each type of hazardous material is being stored or used. Provide calculations for required containment in each area of the. buildings, as per UBC Section 307.2.3.3. City of Carlsbad 071434 6/5/07 Please provide Emergency Power as per UBC, Section 3.7.2.7. Provide a written response to show how Spill Control and Drainage are being handled as required in UBC, Sections 307.2.3 & 307.2.4. Provide the required manual shutoff control for ventilation equipment as per UBC, Section 1202.2.3. S ' h) For fumes or vapors that are heavier-than, air, exhaust shall betaken from a point within 12 inches of the floor. UFC, section 8003.18.2-5. 3. 'None of the data provided seems to address the use of the hazardous materials I being stored in the newH-3 & H-7 storage room. Please address where and how the hazardous materials being storedin the new, H-3 & H-7 storage room are proposed to be used. Please explain any changes in the rest-of the building operations. The Hazardous Materials Report by Klausbruckner & Associates states there are two separate H-3/ H-7 occupancy rooms. But the drawings show only one H-31 H- 7 occupancy room. Please correct. ' Obtain approval from the City of Carlsbad Fire Department of the- corrected hazardous material -technical opinion and report as addressed in UBC, Section 307.1.6. 'Obtain approval to drain the spill control and containment system. across the ' property line to the adjoining lot. The City,of Carlsbad Fire Department and Planning Department must review. PLUMBING (2000 UNIFORM PLUMBING CODE) No plumbing plans provided.. Please address existing and/or new plumbing in the new H-3.& H-7 storage room. •Provide calculations to show compliance with UBC, Appendix 29, (Minimum 'Plumbing Facilities) as per the City of Carlsbad. Please address any required showers. MECHANICAL (2000 UNIFORM MECHANICAL CODE) Detail the required roof access ladder to the roof mounted mechanical equipment. UMC Section 910. Please address the required ventilation for the use of the flammable and/or combustible liquids in the existing non-H occupancy areas of the building. In, ', • Groups B, F, M, and S Occupancies, or portions thereof, where Class I, II, or III - A liquids are used (in any amount), mechanical exhaust shall be provided S 5 sufficient to produce six air changes per hour. Such mechanical -exhaust shall be taken from a point at or near the floor. UBC Section 1202.2.2. 5 5 5 11. Detail exhaust ventilation system compliance with UMC Chapters 5 & 6. '-c 0 - ) 0 • City of Carlsbad 071434 6/5/07 a) Detail the exhaust outlet clearances as per UMC, Sections 504 .5, (Envi?onmental) & 506.9'( 1 Product conveying) b) Clearly show the duct materials are suitable for the intended use UMC, Section 506.1&61P1. c)'. Clearly show the exhaust duct material and gage used for. each duct size. See UMC Tables6-7and-6-8: Separate and distinct systems shall be provided for incompatible materials UMC Section 505.1 Detail duct support as per UMC Sections 506.5 & 610.5-. Detail fire protection as per UMC Sections 506 6 &.61.0.6.,. Detail clearances from combustibles as per UMC Sections 506.7 '& 610.7. Detail protectior from ph'ysical damage as per UMC Sections 506.8 & 6108 0 . - Note If you have any questions regarding this Plumbing and Mechanical plan review list please contact Glen Adamek at (858) 560-1468. To speed the review process, note on this list (ora copy) where the corrected items have been addressed on the plans. DISABLED ACCESS REVIEW LIST DEPARTMENT OFSTATE ARCHITECT 0 TITLE 24 REMODELS, ADDITIONS AND REPAIRS -•; H •. - .. When alterations, structural repairs or modifications or additions are made to ant existing building, that building, or portion of the Wilding affected, is required to comply with all of the requirements for new buildings, per Section 113413.2. These requirements apply as follows a) The area of specific alteration, repair or, addition must ,comply as "new'.' construction ,b) A primary entrane to the building and the primary path of travel td the, haltered area, must be shown to domply, with all accessibility features. c) ,Existing sanitary facilities that seré the remodeled area must be shownto. comply with accessibility features all d) Existing drinking fountains (if any) must be shown to comply with all accessibility features. • • .•. - e) Existing public telephones (if any) must be shown to comply with all ' accessibility features. 0 -, • . END 0 •. 0 • .• .5 City of Carlsbad 071434 6/5/07 VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO 071434 PREPARED BY David Yao DATE 6/5/07 BUILDING ADDRESS 1979 Palomar Oaks Way. BUILDING OCCUPANCY TYPE OF CONSTRUCTION BUILDING AREA Valuation Reg VALUE ($) PORTION (Sq. Ft.) Multiplier Mod. . T.I. H occup. 1751 46.56 81,527 Air Conditioning Fire Sprinklers TOTAL VALUE 81,527 - Jurisdiction Code cb By.O!dinance - - I 8J.26 Bldg. Permit Fee by Ordinance . S. $304371 Plan Check Fee by Ordinance Type of Review LI Complete Review El Structural Only '4 El Other Li Repetitive Fee Repeats • Hourly . I . - Hour * Esgul Plan Review Fee $262 231 Comments: 44. Sheet 1 of 1 - . 5. . . . .. macvalue.doc- 4 - 4 . . S. - . S - •S .• S 5 54 - S 5 'S 55 55 5 5 - . BY G OH46NIAN RACK DESIGN & ENGINEERING Co DATE 412 WEST BROADWAY 204 SHEET NO JOB NO.1W 1 GLENDALE, CA. 91204 SUBJECT TEL (818)240-3010 rax.(ala)240-3813 4/t pDDvc'7J ,igil ,P.3s..O44 Q4kj f.J24O C4 Y "4: 44J. c Off lf COIN Cy N&C053624-i gm 8/30/03 /5 'e : s' ' 33 : " a .fc. >71 4•) .1- 7f3.r?6v)Jf5.'&> 13' '1 y ?rfY" ~ °'. 'a I * .. . ig (7) P31 71 if Carlsbad Fire Department BUI LDI NG DEPT. COPY 'Plan Review Requirements catgo?y. TI, INDUST •. / ••. .' Date of Rport 06-1 1-2007 Reviewed by 4' Name: -. Address: Permit #: CBO7 1434 0 . 0 Job Name: AIR PRODUCTS-CONVERT 1751 SI : Job Address: - 1,979 PALOMAR OAKS WY CBAD you have submitted for review is incomplete; At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached. Please resubthit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: - - CondCON0002136 -. . . . . [MET] *APPROVEDOVED THIS PROJECT HAS BEEN REVIE WED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF •'•. BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION ANI)REQUI1ED TEST, NOTATIONS HEREON,. CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS: THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Compliance -witE all requireménts'-outlined in'the Technical Report prepared for AirProducts by Klausbruckner and Associates shall be determined at time of inspection .. . Entry: 06/11/2007 By: GR . Action: AP - 4 t . ' . . 4 •0 :, . - - * - r - -- •- . - . .4 . * -- - Roof Rafterl 2001 California Building Cáde (91 NDS)1 Ver: 7.01 10 By: NICK SERVIN SERVIN ENGINEERING, INC. on: 04-20-2007: 07:25:07 AM Project: AIR PRODUCTS MECHANICAL - Ldcàtion: RR 1 - Summary: 1.5 IN x 5.5 IN x 8.0 FT 24 O.C. I #2 -'Douglas-Fir-Larch - Dry Use Section Adequate By:60.7% Controlling Factor: Section Modulus/Depth Required 4.34 In Rafter Span Deflections: S - Dead Load: DLD-Intërior= .. 0.11 IN Live Load: .. LLD-Interior- 0.11 IN = L1864 Total Load:. TLD-Interior= 0.22 IN =,L/431 Rafter End Loads and Reactions: •-. : LOADS: RXNS: Upper Live Load: S 80 PLF 160 LB Upper Dead Load: 80-PLF -- 161 LB Upper Total Load: ' -. 160 PLF, 321 LB. Lower Live Load: : 80 PLF 160 LB Lower Dead Load: . . 80-PLF 161 LB Lower Total Load: . 160 PLF 321 LB Upper Equiv.-TributaryWidth: . UTWeq= 4.01 FT Lower Equiv. Tributary Width: . . . LTWeq= 4.01 FT Rafter Data,-.. Interior Span: L= 8.0 -FT Eave Span: . . . . L-Eave= 0.0 FT Rafter Spacing: . Spacing= 24.0 IN O.C. Rafter Pitch: . RP= 1.0 :12 Roof sheathing applied-to top of joists-Top of rafters fully braced. Live Load Deflect. Criteria:- L/ 240 Total Load Deflect. Criteria: .- . L/ 180 Non-Snow Live Load: - Roof Loaded Area: . RLA= . 16.0 SF Live Load Method: . . - - Method = . One Rafter Loads: Roof Live Load: . LL= 20.0 PSF Roof Dead Load: . DL= 20.0 PSF Roof Duration Factor: - Cd= 1.25 Slope Adjusted Spans And Loads: .. - Interior Span: . - . - : - L-adj= 8.03 . FT Rafter Live Load: . . wL-adi= 40 PLF Rafter Dead Load: - wD-adi= 40 PLF Rafter Total Load: :- . wT-adj= 80 PLF Properties For: #2- Douglas-Fir-Larch -V - Bending Stress: . Fb= 875. PSI Shear Stress: - .. - . . -- - - Fv= - 95 - PSI Modulus of Elasticity: - E= 1600000 PSI Stress Perpendicular to Grain: . Fc-perp= 625 PSI Adjusted Properties - - Fb'(Tension): - - Fb'= - 1635 PSI Adjustment Factors: Cd=1.25 CF=1.30 Cr=1.15 • . Fv: - S • -. Fv'= • - - 119 PSI Adiustment Factors: Cd=1 .25 . - .. Design Requirements:• - - S - .• Controlling Moment: - -. - - M=- 641 FT-LB 4.014 Ft from left support of span 2 (Center Scan) . . S • Critical moment created by. combining all dead loads.and live loads on span(s) 2 Controlling Shear: • • . S 288 LB At a distance d from right support of span 2 (Center Span) •• S. • Critical shear created: by combining all dead loads and live loads on span(s) 2 • • -Comparisons With Required Sections: 5 • S Section Modulus (Moment): • . • Sreq= 4.70 lN3 S S= 7.56 1N3 - Area (Shear): •• S S •• S - Areq= 3.63 IN2 .• S • S • A= .8.25 IN2 - Moment of Inertia (Deflection): S S lreq= 8.68 IN4 S • - - 5 • 5 -1= 20.80 .IN4 S /j• . S • C7 . Multi-Loaded Beaml 2001 California Building Code (91 NDS)] Ver: 7.01 .10 By: NICK SERVIN , SERVIN ENGINEERING, INC. on: 04-20-2007: 07:30:55 AM Project: AIR PRODUCTS MECHANICAL - Location: RR2 loading for Mechanical . Summary: : 1.5 IN x 5.5 IN x 2.7 FT / #2 - Douglas-Fir-Larch - Dry Use Section Adequate By: 60.0°Io Controlling Factor: Area [Depth Required 3.44 In . . . Center Span Defléctions: Dead Load: b , -.- *'e exe . • - DLD-Center= -- . 0.01 IN Live Load: . . - LLD-Center= . .0.00 - IN ='Li10254 Total Load: . ct"t )fY c",7''. TLD-Center= 0.01 IN =L13875 Center Span Left End Reactions (Support A): . . . . - Live Load: -, . •. LL-Rxn-A= 68 LB Dead Load: DL-Rn-A= 145 : LB Total Load: .. . .. - TL-Rxn-A= 214 .' LB Bearing Length Required (Béamonlv, support capacity not checked): BL-A= -0.23 IN. Center Span Right End Reactions (Support B): . Live Load: . . . . LL-RxnB= . 146 LB • . Dead Load: .. . •• . . DL-Rxn-B= 223 LB . Total Load: . TL-Rxn-B= 368 LB . Bearing Length Required (Beam only, support capacity not checked): BL-B= •- • 0.39 IN Beam Data: . • : . . . Center Span Length: . L2= . 2.7. FT Center Span. Uhbraced Length-Top of Beam:. . . Lu2-Top= 00 -FT Center Span Unbracéd Length-Bottom of Beam: . . • Lu2-Bottom= . 2.7 FT Live Load Duration Factor: . -. Cd= . 1.00 Live .Load Deflect. Criteria: . -. L/ . 360 :- Total Load Deflect. Criteria: . . . L/ . 240 . Center Span Loading: • . . . . . Uniform Load: ,. . •. Live Load: . . . . wL-2= • 20 PLF, Dead Load: . . . . . wD-2= . -75 PLF Beam Self Weight: . BSW= 2 PLF Total Load: . . . . . wT-2= 97 PLF . Point Load 1 . . . .. . . . . . Live Load: •, . . PL1-2= 160 LB Dead Load: . PD1-2= 161 LB Location (From left end of span): . . . •• . X1-2= 2.0 FT Properties For: #2 Douglas-Fir-Larch . . . •• BendingStress: . . . . . Fb= 875 PSI Shear Stress: . . . FV= 95 . PSI Modulus of Elasticity: . . . E= .1600000 PSI Stress Perpendicular toGrain:. - • Fc_p,erp= - - 625 PSI Adjusted Properties • S . _per Fb'(Tension): . • • • • Fb'= • . 1138 PSI Adjustment Fact6rs:.Cd=1.00 CF--1.30 . • • - . . • • Fv': - • . . • . Fv 95 • PSI Adjustment Factors:. Cd=1 .00:. . . - . • Design Requirements: . . Controlling Moment: . - . . M= 234 FT-LB 1.998 Ft from left support of span 2 (Center Span) Critical moment created by combining all dead loads and 1ive loads on span(s) 2 • ., Controlling Shear: • . . V= 327 -LB Ata distance dfrom right support of span 2 (Center Span) Critical shear created bv,combining all dead loads and live loads on span(s) 2 S • Comparisons With Required Sections: . •. - • . .. S - - : •- Section Modulus (Moment):. • - Sreq= - . 2.47 . 1N3 -. -. . • .- . - • . - .. . S= 7.56 . 1N3 Area (Shear): : • . . . S - • • Areq= 5.16 1N2 • . S • S . A= 8.25 1N2 S • Moment oflnertia (De flOction): •.. S • S lreq=' 1:29 • 1N4 S • •S . • • . . . 1= • -20.80 1N4 S . -S Catalog -Flow SP Fan Bhp Qty Number (CFM) (inwc) RPM (HP) 2 165R4B 2000 .500 948 .287 Altitude (ft): 1270 Temperature (F): 70 Motor Information HP RPM Volts/Ph/Hz Enclosure Mounted 1/3 1725 1 460/3/60 ODP Yes A 20-15/16 B 34-11/16 C 30-3/4-. G •. 2 TSq. . 24 Roof Open. Sq.* - 19-1/2 Unit Wt(lbs) 130 MARK: EFI, co OK PROJECT AIR PRODUCTS C®US , DATE: 0413-2007. ACRU-B ____ Upblast Centrifugal B Exhaust Ventilator - - -. Roof Mounted/Belt Drive STANDARD CONSTRUCTION FEATURES: - All aluminum housing -Backward inclined all aluminum wheel - * Two piece top cap with stainless steel quick release latches - - One piece bottom spinning - Welded curb cap corners - Birdscreen C Vibration isolators- Lifting Lugs - Permanently lubricated _____ ° _____ A ball bearing motors .'Static resistant belts - Adjustable pitch drives through 5 hp motor - Corrosion resistant fasteners - -, Regreasable bearings in a cast iron pillow block housing, rated - at 200,000 hours average life - All fans factory adjusted to specified fan RPM - Transit tested packaging. Standard motors - Ti G shipfactoryinstaIied. .. TSq. t Perfôimance •• DirneAslons (inches) Root opening size for curbs supplied by Cook only. includes tan, motor & accessories. - Sound Data 8 OctaveBands dB (10 _12 Watts) - f_a • - - Accessories: . . -. Fan Curve BD-18 DAMPER- .334 .267 .200 'ower HP) .134 .067- 0.00 yersIurve 0 600 .1200 1800 2400 3000. -• , Point of Operation 0 • - Flow (CFM) • - . .. - - • v5.4.50.9960 - . • . . . 1 "33' 5 6 7 8 LwA 80 63 59 55 50 70 • 59 -10.0 ROOF CURB RCG 22-9.5 H W/CANT W/TRAY I • - . . • 0.80 0.60 SP I ' • ,. • •. • (inwc) 0.40 a,. 0.20 - Fan Curve Legend CFM vsSP - CFM vs HP Mark Qty Description A Max B C Sq # Panels [F1 2 BD-18 DAMPER' 5-3/16 1-7/8 - 17-3/e 1 .' icOOI( PROJECT AIR PRODUCTS DATE: 04-13-2007 B D Gravity Backdraft Damper. STANDARD CONSTRUCTION FEATURES: .02 Aluminum blades- .06 aluminum frame.- Aluminum hinge pins - Nylon bushing. - t t f I Flow 40 + ____1 ____ -1-•• - L - Dimensions (inches) 4 .4 4 4, • .4 4 'S 4 4 4 4 .,,& S 'S ,•- PROJECT: AIR, PRODUCTS - DATE: 04-13-2007 R CG - Galvanized Steel-,' . Canted Roof Curb 4, STANDARD CONSTRUCTION FEATURES:*Wood Nailer * 18 gauge galvanized steel - 1-1/2 V Sq 3'ibs. density thermal and'accousticai. - \ FSq. insulation - Continuously welded corners.- - , •• - : A - Wood nailer Options:(As noted below*) ' Ht 1) No wood nailer (deduct 1-1/2 '0 '0 - for actual height) 2) Damper tray, • r ___________ ___________________ ________ - L~oof.open "-Insulation Sq.- ing - Optional Damer Tay ' 'Dimension S ( incheis) -- Mark '. Qty, Description Ht Options*, A F Sq. V Sq. W Sq. - Roof Opening [EF1 2 RCG22 95 2 11/2 221/2 30-1/2 15-3/4 191/2 " - r . . .4, , .4. 4 , 4.-, 4 . 4 . .. .4% S -, . 4 4 - .4 .4 •44 - • '-.4, 4 4, '4 . 4 . . ,•4 4 .4- +, 7 .- . S - . , 4. . •.., . .4'- . . , -. - -_ - .. p - - 3.. 4 .'- 4 .1'' ' .. • ., . • 4 - -, 4- -, I ',,' '.4.' 1 ' 4 - I 4'- ' 4 4 - 4 4 I , , I •. . 1• • .4 ., 4,'4 . 4 * 4.• . •. *4 , 3. 4 .4 A, ' 4 , ,,, 5 4 - - . 3. , . -.4 4- - .4 . '4. %_ 4. S. 4 -.- 4 - .4 , 4 - •' 4 4' .4 r ', 5,4 _5_ 4 --' ' :- - . -.,-- , , .-- - -: - . 4 .4__ .. .4 4 5_ , 5.• 3. ".4. 4 4 _4 4 - - V5.4 '. I , • .4 . .4 . ' - - l-4. .,• ,_- . 4 75 ' • 4' 4 . 4 1 1- 5, 4 '.4 .4 - --- .4 4 '5• , -I . - -- .4 - - , .4 5- .4 -. 4 .4 4'g I • •; - - ' - :---- -+• "I - •_ • . -4. I - •• . - I - 4, 4 • * - 4 - 4-.,. 4- A 30-1/2 3 C 10- LXW 69x69 :L 'TSq. 36 Roof Open. 5q•*' 3171/2 Unit Wt(lbs) .604 1 2 3 4 5 6 7 8 LwA dBA Sones 8587868480787772 86 75 25 - .'. Fan Curve - 1,50 Accessories:. ROOF CURB RCG'34-9.5H W/CANTW/TRAY .. 0.90 SP- - ' . . (inwc) 0,60 0.30 Fan Curve Legend CFMvsSP CFMvsHP .890 .600 Power HP) .400 .200 0.00 ywiru Curve - - - - Q . 1500 - 3000 4500 • • 6000 .. 7500 Point of Operation 0 . • . Flow (CFM) • v5.4.50.9960 .' COOI( ' jjJ PROJECT 'AIR PRODUCTS C ' : DATE: 04-13-2007 H Hooded Filtered Supply V&ntilàtor - Extruded Aluminum Propeller ".. Roof Mounted/Belt Drive _______________ Lx W. STANDARD CONSTRUCTION FEATURES =0-' Extruded aluniinum propeller - Spun steel - ,Galvanizedhood - Heavy duty steelpower :'• A assembly- Welded curb cap corners - Adjustable c pitch drives through 5 h motor - Regreasable bearings in cast housing rated at 200 000 hours average life - Propellers are staticall and dynamically balanced;- Washable filters - Quick ________ T Sq. L B release filter retainers Corrosion resistant -'- - fasteners - Static resistant belts All fans factory, adjusted to specified..RPM.' NOTE: . •'-. Dimensions (inches) F Size 48-60 requires field assembly of hood. Perfarmance Qty Catalog' Number Flow (CFM) SP (inwc) Fan RPM Bhp (HP) 2' 24HEF713. 5000 .500 1244 .980 Altitude (ft): 1270 Ternperare (F): 70 - Motor Information '. Roof opening size for curbs supplied by Cook only. - Includes fan, motor & accessories. - Sound Data 8 Octave Bands dB (10 Watts) -' HP, RPM Volts/Ph/Hz Ehclósure Mounted 1 1725 115/1/60 ODP Yes, . V PROJECT AIR PRODUCTS 0 ATE 4-13-2007" RCG Galvaniied Steel ' ' ,. CantédRoof Curb V V V V •:_VV; V V STANDARD CONSTRUCTION FEATURES:. Wood Nailer 18 gaugegalvanized steel - 1-1I2"T V V V Sq. - V V 3 Ibs.densitythermal and accoustical V F Sq. • V V V insulation - Continuously welded corners V V Wood nailer. . . 'A V V 4 V 4 , . Options:(As noted below*) • -. V • - Ht. V 1) No wood nailer (deduct 1-1/2". • • V V V for actual height) 2) Damper tray. [\ \,—insulation V • V V V V F-- Roof Opening w sq.Tray V V V V V 4 . :7 . - . - V •' 4 V ' Dimensions (inches) PV V V - •. Mark . VV Qty. V Description Ht - - 0pt1ons A F Sq. V Sq. W Sq. Ro Opening V V SF1 - -. - V 2 RCG34 9.5 2 .- 1-1/2 42-1/2 27-3/4 31-1/2 • V .1 }V BY\ G OHANIAN RAdK DEIdN & EN1INEERINd do 1 MATE....2-14-07 412 WET BROADWAY, ØUITE #204 SHEET NO RD -11829 t dLENI.LE,dA 91204 JOB NO SUBJECT 'mL(818)Uo-3810 FAX (818)240-3813 4 - 'V .• STRUCTURAL CALCULATIONS 9FSTORAGE RACKS FOR 'V AIR PRODUCTS 1979 PALOMAR OAKS WAY V CARLSBAD CA 92009 C, ,', • V 4 V •4V V - V :, 1' 4. V • V V • • - V.: 4 V • ' PER CBC 2001 V EDITION •• V - 1 •• : • VVV OH4* Al I— STORAGE RACKS CAPACITY rn EXP 6/30/07 5000 # / LEVEL / 4 1V CALM 1 THRU 4 DRAWINGS RD-11829 V • • - V V - ••VV• V V •• - V V - VI V •V V •V V VV V. - V ,.V V ••V V •V • V V:. . • V -• V, • V VVVV V : • ,V V • . - • •V • V i w C 6ö7 BY G OHANIAN RACiK DEI(N & ENdINEERIN( CIO.—3 DATE - 412 -WEØT BROADWAY, UITE #204 'SHEET. NO....................... (LENDALE, dA. 91204 -JOB NO. ...!?T...... SUBJECT TEL (818)240-3810 FAX (818)240-3813 - ---:-.- V.. COLUMN -ANALYSIS 1' 1 2 Fy5O KSI J~J = 70x1 799 Fe irxE_g A=.78 X1;2 ;( rx .i):. S X_ X -8O i_i_45 F=F(1— !28KSI t09 'Max S Fb 24K ,P =F xA22K Pa 'V V P6 12 V 'V V V . COMBINED STRESS RATIO. E ._-t 3133 V P0M _ Q 12 +24,_..9 <,•• V V VV V V 51K BASE PLATE ANCH. TENSION = 12—(2.6x3.5') =4'8 K V '- .8"x5"x3/8"- V 6 V V V V • ,/TBASE PLATE .' ANCHOR SHEAR 18K 71010j, (2)-1/2"0 HILTI KWIK BOLT 3 ANCHORS ESR-1385 OR APPROVED EQUAL DESIGNED FOR 1/2 STRESS (NO SPECIAL INSPECTION REQ D) '. ALLOW. TENSION=.9 K : '' • ALLOW SHEAR=1 5K _4<1.33 RACK COLUMNS DESIGNED SUCH THAT IF THE FRONT COL IS DAMAGED. THE REAR COL. HAS EXTRA CAPACITY TO SUPPORT - ' . •. - THE FULL LOAD OF THAT BAY (SEC 2222-5) V •V V •V -V V •,• "K 'VV •V MOMENT AT BEAM CONNECTION 7/16"0 RIVET © '.100 © I A 1 Fy =79 L. © ©'J Va = 1 x79x 4 = 3K © 0 III Ma =3'<x2x xl 33-32 K 4 PIN CONN.0 © CONN.- b 71 .4' V. ç ' - I V V V •V I , •. - V. - V •V 'V tI.V V •VVV AIR PRODU Material Safety Data Sheet Version 2.3 MSDS Number 300000005296 Revision Date 03/18/2007 Print Date 06/10/2007 1. PRODUCT AND COMPANY IDENTIFICATION Product name TEOS Chemical formula C8H2004Su Synonyms Ethyl Silicate,Tetraethoxysilane Tetraethyl Silicate Product Use Description : Semiconductor Processing Company. : Air Products and Chemicals, Inc 7201 Hamilton Blvd. Allentown, PA 18195-1501 GST No. 123600835 RT0001 OST No. 102753981 TQ0001 Telephone : 1-610-481 -4911 Corporate 1-800-345-3148 Chemicals Cust Sery - 1-800-752-1597Gases/Electronics Cust Sery Emergency telephone number 800-523-9374 USA 01-610-481-7711 International 2 COMPOSITION/INFORMATION ON INGREDIENTS Components CAS Number Concentration (Weight) Silicic acid (H4SiO4) tetraethyl ester 78-10-4 100% Concentration is nominal. For the exact product composition, please refer to Air Products technical specifications Contains no other components or impurities which will influence the classification of the product 3 HAZARDS IDENTIFICATION Emergency Overview Keep away from heat and sources of ignition Components of the product'may affect the nervous system. Combustible Liquid. - Severe eye irritant; - Moderate skin irritant. Potential Health Effects Inhalation May cause central nervous system effects such as headache, nausea dizziness confusion, breathing difficulties Severe cases of overexposure can result in respiratory failure. Irritation of mucous membranes. Eye contact Severe:eye irritation. - Skin contact -- : If absorbedthrough the skin,'may causecenfral nervous system effects, such 1/8 Air Products and Chemicals Inc TEOS a MriaI Safety Data Sheet E.Ion42 3.. MSDS Number 300000005296 Revision bate 03/18/2007 . ; • Print Date 06/10/2007 as headache, nausea dizziness, confusion, breathing difficulties Causes skin - irritation. - 4 Ingestion . • ','r • 4 -, - - S : May, cause central nervous system effects, such as headache, nausea; • vomiting, abdominal pain, dizziness, confusion, breathing difficulties. Severe cases of overexposure can result in respiratory failure.f- Chronic Health Hazard : This product contains no listed carcinogens according to IARC, ACGIHNTP arid/or OSHA in concentrations of 0.1 percent or greater. r Exposure Guidelines .• .- - -, --- r-.-- - ••. Target Organs Eyes Skin Lungs.- —t- ,-4 - - -• --, Uver. • L;. -. Blood - ; Kidney. •'f 1i:-.:-• •- •. . Central nervous system 4 Condition • Aggravated Medical - - 4 Kidney disorders Neurological disorders Liver disorders Eye disease Skin disorders and Allergies. A -4. FIRST AID MEASURES 5 S :.. •. - --- .-4.---S•- . • . .. - General advice Seek medical advice If breathing has stopped or is labored give assisted respirations Supplemental oxygen may be indicated If the heart has stopped, 4 trained personnel should begin cardiopulmonary resuscitation immediately. .! .- Eye contact .'_4 -.-* --011 - : Rinse immediately-with plèntyof water also under the eyelids for at least 20 minutes: Remove contact lenses. - - - Skin contact - • ..., S iate Wash . off immedly with plenty of water for at least 20 minutes. Immediately., - remove contaminated clothing and any extraneous chemical if possible to do - so without delay. - • •-.-,: - . Ingestion : Never give, anything by mouth to ariUnconsôious person. Immediately give - 'largequantities Of water to drink. Induce vomiting if person is conscious -. Prevent aspiration of vomit. Turn victim's head to theside.. Inhalation Move to fresh air. * . -S •,.5 a4- --•--:--. ••Y - - 4.'•'_ . . - •• .,j .5 _*- _•5. . •., 5. FIRE-FIGHTING MEASURES. - ., . •- - :-+'. :-. :.. '.. SuitabW extinguishing media Alcohol resistant foam Carbon dioxide (CO2) 'a Dry chemical.' . • :. - - pry sand. 4 Limestone powder. - . S - 44: -- . . • - -- . - Specific hazards Burning produces noxious and toxic fumes In the event of fire, cool tank'with - - . - ... • -- - . 4, - Air Products and Chemicals,lnc 2/8 4 A544 4 fT T EOS 'V Material Safety Data Sheet Version 2.3 MSDS Number 300000005296 Revision Date 03/18/2007 Print Date 06/10/2007 water spray. Downwind personnel must be evacuated. Fire or intense heat may cause violent rupture of packages. Flash back possible over considerable distance. May form explosive mixtures in air. Special protective equipment : Use personal protective equipment. Wear self contained breathing apparatus for fire-fighters for fire fighting if necessary. Further information : Do not allow run-off from fire fighting to enter drains or water courses., Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations. -. ACCIDENTAL RELEASE MEASURES Personal precautions Wear suitable protective clothing gloves and eye/face protection Use self- contained breathing apparatus and chemically protective clothing Remove all sources of ignition. Evacuate personnel to safe areas. Environmental precautions : Prevent spilled product from entering streams or drinking water supplies. Local authorities should be advised if significant spillages cannot be contained. Construct a dike to prevent spreading Shut off or remove all ignition sources Methods for cleaning up Contact Air Products' Emergency Response Center for advice Approach suspected leak areas with caution Absorb with inert absorbent materials such as: Dry sand. Vermiculite. Activated charcoal. Place in appropriate chemical waste container. Additional advice : if possible, stop flow of produdt. HANDLING AND STORAGE . . Handling See 'Flammable and Combustible Liquid Code NFPA No 30 National Fire Protection Association Boston MA Emergency showers and eye wash stations should be readily accessible. Adhere to work practice rules established by government regulations Avoid contact with eyes Use personal protective equipment When using do not eat drink or smoke Storage Keep containers tightly closed in a dry, cool and well ventilated place Keep away from heat and sources of ignition. Keep in a dry, cool place. Keep away from Oxidizers. Technical measures/Precautions .. Keep away from open flames, hot surfaces and sources of ignition. Storage Temperature : 32 - 104 °F (0 - 40 °C) 8 EXPOSURE CONTROLS /.PERSONAL PROTECTION Engineering measures Maintain process conditions to ensure temperature is below product flashpoint 3/8 Air Products and Chemicals Inc TEOS 1 -4 ' •- 4-J. 4 M.ErlaI Safety Data Sheet Version' 2 3 " - MSDS Number 300000005296 Revision Date 03/18/2007 ,' -. - Print Date 06/10/2007 t,Ensure adequate ventilation .4 'accessible, Provide readily viiash stations and safety showers: Provide natural or explosion-proof ventilation àdéquate-tó ensure concentrations are kept below exposure limits. , 4. ,- Personal protective equipthent - -. Respiratory protection : Use Air Purifying Respiratàr'with organic vapor cartridges when exposure is likely.. . - 14 1 •-.- Hand protection : Impervious gloves... Silvershield gloves. - - •', Butyl rubber 1 . The breakthrough time of the selected 'glove(s) must be greater than the intended use period . Eye protection ' pt•,,'z ',-.'.--,'' Chemical resistant goggles must be worn I , • ''4'' t-., •••. , 4•'4 4 Skin and body protection 4,' •' 4. '4 I Long sleeve shirts and trousers without cuffs - " . , .4 •1 '. -C ,' • - -, ..: '.._ . ,,. .. 0 - ' i -. - . , . . . . ., .4 Environmental exposure : Prevent spilled product from entering streams or drinking water supplies. Local controls" authorities should be advised if significant spillages cannot be contained - Construct a dike to prevent spreading Shut off or remove all ignition sources Special instructions for : Provide readily acdéssible' eye wash stations and safety showers. Wash at the -. protection and hygiene end of each workshift and before eating, smoking or using the toilet Exposurelirnit(s)' .'. '4, ,'0 - . ,,•. ..' . {. - •' :'- , - . ', '- . -.4. .' , / .. •..it . ?. . Silicic acid (H4SiO4), . Time Weighted Average (TWA): ACGIH , - ;- 10 ppm . -- tetraethyl éster. . . 1 Silicic acid (H4SiO4), ;-. RecOmmended exposure limit (REL):NIOSH.. 10 ppm 85 mg/m3 tetraethyl ester.\ ,•-',,r" .,'.' ,'.-',.' ').i.:"'4-.. 4"4 4 4 •4 . ' - Silicic acid,(H4SiO4), '-- OSHA Z1• ' .. .?--- , - 100 ppm. ' 850 mg/m3 tetraethyl ester -• . . - . •.; •. 4' .. . . . Silicic acid (H4SiO4), ..PEL: Time Weighted Average (TWA): OSHA Z1 ' . 10 ppm 85 mg/m3 tetraethyl ester . . ' . . . . . . : . . , '• Silicic acid (H4SiO4), - ,Time Weighted Average (TWA) Permissible 4' -,, ,to ppm 85mg/rn3 tetraethyl estér'- Exposure Limit (PEL): US CACEL-- .4 .. ,. '-,-.1. •,. ' I 9. PHYSICAL AND CHEMICAL PROPERTIES -; •44 , . 0 ,, - ' •'-': .' t: ...... Form Liquid .. .,,. , .••; 4. Color Colorless Odor - .........- 44' I•• ,.• ......... .4;I'4'4 4 4._4 : Alcoholic. - Poor warning pro es at low concèntrations.' . 4,J4.-.. 44. Molecular Weight 208.13 g/mol 4• 44 •4 ..•!:•/ Relative density >0.934 (water =1) -. 4 44. 4 .4' ,• 'f'• -, - 4 C4• 4 4 • .-,.- .- . -4'' rn Air Products and Chemicals Inc -4/8..- '4" TEOS 1 ' 4- - - 4 4'-. 4 . 0. - •L, 4'• - - . ,•,'44' ., 4- .t, -- 4 4,, -4 Material. Safety Data Sheet Version 2.3 MSDS Number 300000005296 Revision Date 03/18/2007 Print Date 06/10/2007 Vapor pressure : 2.83 mmHg at 20 °C Boiling point/range : 334°F (168 °C) Melting point/range : -116 OF (-82 °C) Flash point : 52 °C Autoignition temperature : 260 °C Upper flammability limit : 5.75 %(V) Upper flammability limit : Not applicable. Lower flammability limit : 0.9 %(V) Lower flammability limit : Not applicable. STABILITY AND REACTIVITY Stability : Stable under normal conditions. Conditions to avoid : Heat, flames and sparks. Exposure to air. Exposure to light Exposure to moisture. Materials to avoid : Oxidizing agents. Strong acids. Strong bases. Carbon steel. Plastics. Hazardous decomposition : Hazardous combustion products: products Carbon dioxide (CO2). Carbon monoxide. Silicon Dioxide. Hydrolysis products: Ethanol. Silicon compounds. Hazardous reactions : Decomposes when moist. TOXICOLOGICAL INFORMATION • Acute Health Hazard Ingestion : LD50: - No data available. Inhalation : LC50: Harmful by inhalation. • Skin. : LD50: 4E :•:• Air Products and Chemicals,Inc . TEOS .... . •.' Material Safety Data Sheet Version 2 3 / MSDS Number 300000005296 sion; cRviDäte03/18/20O7 ... . :... Pnnt Date 06/10/2007 .. Toxic in contact with skin ....: .. 4 Eye irritation/corrosion Severe eye irritation H. . . ,,.•- -.1. Acute dermal Skin irritation irritation/corrosion - - . '--. 12.ECOLOGICALIN FORMAT ]ON . '•-:--.. Ecotoxicity effects 3 Aquatic toxicity No data is available on the product itself Toxicity to other organisms No data available Persistence degradabihty and .. Mobility No data available Bioaccumulation -'- _d No data is available on the product itself ). 13 DISPOSAL CONSIDERATIONS Waste from residues I unused lContact supplier if guidance is required products --1 f•• • Contaminated packaging Dispose of container and unued contents in as with federal state and local requirements -14 TRANSPORT INFORMATION. '. ;'. - •-. - DOT Proper shipping name Tetraethyl silicate Class 3 UN/ID No UN1292 Packing group Ill IATA Proper shipping name Tetraethyl silicate ft , Class 3 UN/ID No UN1292 Packing group Ill IMDG Proper shipping name TETRAETHYL SILICATE IV- Class 3- No. UN1292 Air Products and Chemicals Inc 4 TEOS S- • -. -•:-4 -'--..--• •- / -S - - - •- -. - -- I Material Safety Data Sheet Version 2.3 .. .. . S MSDS Number 300000005296. Revision Date 03/18/2007 Print Date 06/10/2007 Packing group : : III TOG . Proper shipping name : TETRAETHYL SILICATE Class . : 3 UN/ID No. : UN1292 ., . Packing group. : III Further Information . . Note: if regulated as a hazardous material (Dangerous Good) in transportation, please refer to shipping papers or contact Air Products for complete shipping description information. REGULATORY INFORMATION OSHA Hazard Communication Standard (29 CFR 1910.1200) Hazard Class(es) Combustible Liquid. Irritant. Country Regulatory list Notification USA . TSCA Included on Inventory. EU EINECS Included on EINECS inventory or polymer substance, monomers included on EINECS inventory or no longer polymer. Canada DSL . Included on Inventory. Australia AICS Included on Inventory. Japan ENCS Included on Inventory. South Korea ECL Included on Inventory. China SEPA Included on Inventory. Philippines I PICCS . Included on Inventory. EPA SARA Title HI Section 312 (40 CFR 370) Hazard Classification: Acute Health Hazard Fire Hazard. EPA SARA Title III Section 313 (40 CFR 372) Component(s) above 'de minimus' level: None. US. California Safe Drinking Water '& Toxic Enforcement Act (Proposition 65) This product does not contain any chemicals known to State of California to cause cancer, birth defects or any other harm. OTHER INFORMATION S NFPA Rating .. 5 . Health : 2 Fire . : 2 Instability : 0 HMIS Rating S S S 7/8 Air Products and Chemicals,Inc S TEOS Storage, Prepared by : Air Products and Chemicals. Inc. Global EH&S Product Safety Department For additional information, please visit our Product Stewardship we& site at http:I/www.airproducts.com/productstewardship/ - - tr I. ,. r-- ',.. -. - 7 - . - . S S - -. .5.- '-• S - . . ) S . • ---"5--S •- - --. . • .. - S - • . . S I ,, *•. S. •5_•• ;-•.• ... _-. ••-5-• - - -. • - :'Air Products and Chemicals,lnc . . . TEOS NR DUCTS AA,- Ma'teeia[Sadety. Data Sheet .. Version 1.8. . . .. MSDS Number 300000005308 Revision Date 03/20/2005 Pnnt Date 06110/2007 1. PRODUCT AND COMPANY IDENTIFICATION. . •. .; Product name : TOMCATS .. .. Chemical formula C4H1604Si4 Synonyms 1 3 5 7, Tetramethylcyclotetrasiloxane Cyclotetrasiloxane 2,4,6.8 Tetramethyl,TMCTS Product Use Description Semiconductor Processing . Company . : Air.Products and Chemicals,lnc 7201 Hamilton Blvd. . . Allentown, PA 18195-1501 Telephone : 1-800-345-3148 Chemicals . -. 1-800-752-i597. Gases and Electronic Chemicals Emergency telephone number 800-523-9374 USA . :. 01-610-481-7711 International . 2 COMPOSITION/INFORMATION ON INGREDIENTS Conentration is nominal..For the exact product composition, please refer t Air Products technical specifications. Contains no other components or impurities which will influence the classification of the product. 3 HAZARDS IDENTIFICATION Emergency Overview Keep away frOm heat and sour cepfignition. • .,, . Flammable. ,. . •, Moderate respiratory irritant . Moderate skin irritant . • Irritating to eyes. -. . Decomposes in contact with water Harmful in contact with skin Harmful if swallowed. .• . May react with water to generate flammable hydrogen gas. Potential Health Effects Inhalation May cause nose,. throat and lung irritation. Inhalation of vapors and/or aerosols in high concentration may cause irritation of respiratory system. Eye contact Contact with eyes may cause irritation 117 Air Products and Chemicals Inc TOMCATS Components .•, ,. CAS Number Concentration (Weight) 2,4,6,8-Tetrámethylcyclotetrasiloxane 2370-88-9 100 % I •,._ S. - Material Safety Data Sheet Version .1.8. . -. . ' ,MSDS Number 300000005308 Revision Date 03/20/2005 -.-i- f' '. SPrint Date 06/10/2007 V ' a Skin contact Causes skin irritation Harmful in contact with skin Symptoms of overexposure 'may be headache, dizziness, tiredness, nausea and vomiting. Ingestion Harmful if swallowed Chronic Health Hazard : This product contains no listed carcinogens according to IARC, ACGIHNTP and/or OSHA in concentations of 0.1 percent or greater. 4 .5 • " Il' ' Exposure Guidelines Target Organs Respiratory system Skin. Eyes ;. .• 4' 4.' t Symptoms Repeated and/or prolonged exposure to low concentrations of vapors and/or aerosols may cause Sore throat ., Aggravated Medical Condition 4 -a ne , .,, . .. 7 V Adverse respiratory effects (such as cough, tightss . of chest or shortness of breath) Asthma Skin disorders and Allergies. Adverse. skin effects (sticlias rash, irritàtior or corrosion). Adverse eye effects (such as conjunctivitis or corneal damage) Eye disease ., FIRST AIDMEASURES S •. ''554' • S • - General advice Seek medical advice If breathing has stopd or is labored give assisted' \ respirations. Supplemental oxygen may be indicated. If the heart has stopped, 'trained personnel should begin cardiopulmonary resuscitation immediately. - 5- Eye contact Rinse immediately with plenty of water, also underjhe eyelids for at least 20 minutes. Remove contact lenses. S . .......... Skin contact Wash off immçdiately with plenty of water.for at least 20 minutes. Immediately remove contaminated clothing and any extianeoug chemical, if possible to do so without delay. 4 'S I * Ingestion : If a person vomits when lying on his back, 'pIace him in the recovery position. .4.,, Do not induce vomiting. Never give anything by mouth to an unconscioLi person. Gently wipe or rinse the inside of the mouth with water. Prevent,•. aspiration of vomit Turn victim's head to the side Inhalation : If breathing has stopped or is labored, give assisted respiratio'ns. ' Supplemental oxygen may be indicated. If the heart has stopped, trained personnel should begin cardiopulmonary resuscitation immediately. Move to fresh air. . . - ;... '-.,.. '. •. . . - - . FIREFIGHTING MEASURES Suitable extinguishing media : For smaller fires, use dry chemical or, carbon dioxide, do not use water. For. ... large fires, flood fire area with water from as far as possible, using a protective barrier and appropriate pdrsonái protective equipment. - . .- Carbon dioxide (CO2). - ...-.. '- •. . . . •. . 5---- •'••••4 -1 •-. ,-*- * . .••. . '. -. : .' , .: '.,. . '... :' 217 Air Products and Chemicals Inc . I 1TOMCATS I ( . . . . .... 4 5. 5- - .5 5 -•.I .-i . •S • S V, -. St is.. Material Safety Data Sheet Version 1.8 MSDS Number 300000005308 Revision Date 03/20/2005 Print Date 06/10/2007 Dry chemical. Dry sand. - Limestone powder. Extinguishing media which : Water. must not be used for safety Alcohol-resistant foam. reasons Specific hazards Fire or intense heat may cause violent rupture of packages Flash back possible over considerable distance May form explosive mixtures in air. Burning produces obnoxious and toxic fumes Decomposes in contact with water. .' Special protective equipment 'Avoid contact with the skin. Use personal protective equipment. Wear sell for fire-fighters ' ' contained breathing apparatus for fire fighting if necessary. Further information Do not allow run-off from fire fighting to enter drains or water courses .6. ACCIDENTAL RELEASE MEASURES Personal precautions ' Use self-contained breathing apparatus and chemically protective clothing. Wear suitable protective clothing, gloves and eye/face protection. Remove all sources of ignition. Evacuate personnel to safe areas. Environmental precautions. Shut off or remove all ignition sources. Methods for cleaning up Approach suspected leak areas with caution. Contact Air Products' Emergency Response Center for advice Absorb with inert absorbent materials such as Dry sand Vermiculite Activated charcoal Place in appropriate chemical waste container. Additional advice : Protect from water; If possible, stop flow of product.' 7. HANDLING AND STORAGE Handling Do not breathe vapors/dust. Emergency showers and eye wash stations should be readily accessible. Adhere to work practice rules established by government regulations Avoid contact with eyes See Flammable and Combustible Liquid Code" NFPA No. 30, National Fire Protection Association, Boston, MA. Use personal protective equipment When using do not eat drink or smoke Storage ' To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded. Keep containers tightly closed in a dry, cool and well ventilated place Keep away from heat and sources of ignition. Keep in a dry, cool place; Keep away from Oxidizers. Store in an area suitable for water reactive materials. Minimize exposure to air. Exposure may cause material to degrade. Store under a nitrogen atmosphere. Technical measures/Precautions Keep away from open flames, hot surfaces and sources of ignition Keep away from heat sparks open flame water, alcohols silanols or other hydroxyl containing compounds • :I.4' ' •..-L . • Air Products and Chemicals,lnc 4). . Material Safety DataSheet Vêsion AS MSDS Number 300000005308 Revisión'Date 03/20/2005 - Print Date 06/10/2007 Storage temperature 32- 104°F (0 40 °C) - 8. EXPOSURE CONTROLS / PERSONAL PROTECTION - S . ,- -4-- •'-•.: ' Engineering measures • Use explosion proof equipment Provide readily accessible eye wash stations and safety showers Provide natural or ei0I6bio'h-0'ro6f ventilation adequate to ensure concentrations are kept below exposure limits Personal protective equipment Respiratory protection :. Wear, appropriate respirator when ventilation is inádéquate. Wear a full-face respirator with organic vapor cartridges when exposure is likely. Hand protection Impervious : gloves. . •••. - - .4-.- 5. *5 -4 • • Butyl rubber Viton gloves. - breakthrough time of the selected glove(s) must be greater than thè...-•-,The intended use period, Eye protection 44 Chemical safety glases - Chemical resistant goggles must be worn 4 - . - Skin and body protection : Long-sieeve shirts and -trousers without cuffs.' Impervious clothing Environmental exposure Shut off or remove all ignition sources controls Special instructions for : Provide readily accessible eye wash stations and safety showers. Wash at the protection and hygiene. érid.bf éaOh wórkshift and before eating, smoking or using the toilet. Remove. contaminated clothing. Drench affected area with water for at least 15 rhinUtes 9 PHYSICAL AND CHEMICAL PROPERTIES. . S -- •• 44. - Form : Liquid . . . '.• -, . 04, '-..• * Color Colorless Odor Ether like Molecular Weight Relative vapor density 8 (air = 1) Heavier than air'.s. 4- - 1,4 Relative density 4 0..991, (water = 1) 4- I - 7.02 68 °F °C)4- ' Vapor pressure mmHg at (20 5. 4. '' -'• - - - - - ... - •-. - - 's-A ,4. j4. - 44 5- 'I 4 4/7 f 4 Air Products and Chemicals,lnc - - '-• " - - TOMCATS '4-*5• .- - '4-- - •_- - . ':'- - - • - .., . . -. Material Safety Data Sheet Version 1.8 MSDS Number 300000005308 Revision Date 03/20/2005 Print Date 06/10/2007 Boiling point/range : 275 OF (135 °C) Melting point/range : -85 OF ( 65 °C) Flash point : 24 °C Autoignition temperature : 482 OF (250 °C) Upper flammability limit : >10.0%(V) Lower flammability limit : 0.7 %(V) Water solubility : Insoluble. Decomposes in contact with water. STABILITY AND REACTIVITY Stability : Stable under normal conditions. Conditions to avoid : Heat, flames and sparks. Exposure to moisture. Materials to avoid : Oxidizing agents. Humid air. Water. Acids. Bases. Alcohols. • Hydroxyl containing compounds. Silanols. Heavy metals. Hazardous decomposition : Hazardous combustion products: products Hydrogen. Carbon monoxide. Carbon dioxide (CO2). Silica. Hazardous reactions : Decomposes in contact with water. TOXICOLOGICAL INFORMATION Acute Health Hazard Ingestion • : Harmful if swallowed. Inhalation : No data is available on the product itself. Skin. • : Harmful in contact with skin. Eye irritation/corrosion : Eye irritation. Acute dermal : Skin irritation. irritation/corrosion .• 5 •: •, • Air Products and Chemicals,lnc TOMCATS 4 - -. i • '..-: .. • .. - f - . *_•• ...- * - - ateriaI Safety Data Sheet Version 11'.8 MSDS Number 300000005308 ok Revision Date 03/20/2005 Print Date 06/10/2007 Al .-- -- - 12. ECOLOGICAL INFORMATION ..- •••' . r Ecotoxicity effects Aquatic toxicity ,. No data is available on tli'e product itself 4 Toxi6ity td other organisms oi No data available r . . - ••-- * Persistence and degradability If Mobility,No data available Bioaccumulation No data is available on the product itself -.4 . .' ., . • .__'.4•_,_..'_ 13 DISPOSAL CONSIDERATIONS r Waste from residues / unused 4 1 Contact supplier if guidance is required • roducts p . '• . • - - --. . . • ................................................ Contaminated Dispose contents in federal, of container and unused accordance with state, packaging : and local requirements 4 • . . . '- 14 TRANSPORT INFORMATION .1 *__ -4 • CFR 4 •••.•- .*,•_*_•' .. .-, 4 .-•r .4 .( #•.•4 - Proper shipping name Flammable liquids n o s (2 4 6 8 Tetramethylcyclotetrasiloxane) Class. : 3 • ;. . :.. ,}•. .. . -' UN/IDNo UN1993 ' '-Packing group : Ill - •.-.:. '"- .-.. :-' • IATA ' Proper shipping name Flammable liquid n o s (246 8-Tetramethylcyclotetrasiloxane) Class 3 UN/ID No UN1993 -- 4_ - - • Packing group . . •• Ill Kj • *. • . - l!v1DG• . ,..-•. .-- .. . - :- . *4 •'' ........................................................-' - Proper shipping name : FLAMMABLE LIQUID,N.O.S:•(2,4;6,8;Tetramethylcyclotetrasiloxane) Class 3 UN/ID No UN1993 - Packing group Ill 4. - 4.'.- CTC Proper shipping name FLAMMABLE LIQUID, N 0 S (2,4 6 8 letramethylcyclotetrasuloxane) 14 Class : UN/ID No 3 - . * - .•. • - UN1993 .4 . III *4 3 Packing group - -c -4 6/7 -4- Air Products and Chemucals,tnc / ' TOMCATS '--' t: - • -•- • - - 4 4. Country ' Regulatory list - Notification USA , TSCA Included on Inventory. EU EINECS Included on EINECS inventory or polymer substance, monomers included-6n EINECS inventory or no longe? polymer. Canada DSL ' Not on Inventory: Australia AICS Included on Inventory. Japan . ENCS Included on Inventory. South Korea. ECL Not on Inventory. China SEPA ' . Included on Inventory. Philippines I PICCS Included on Inventory. Material Safety Data Sheet Version 1,8 - MSDS Number 300000005308 Revision Date 03/20/2005 Print Date 06/10/2007 15. REGULATORY INFORMATION -. 4 OSHA Hazard Communication Standard (29 CFR 1910.1200) HázardClass(és) Flammable. Irritant. - EPA SARA Title III Section 312 (40 CFR 370) Hazard Classification: Fire Hazard. Acute Health Hazard , US. California Safe Drinking Water & Toxic Enforóement Act (Proposition 65) This product does not contain any chemicals known to State of California to cause cancer, birth defects or anyother harm. 16. OTHER INFORMATION : NFPA Rating , ' -- Health . : 1 Fire :3 Instability ': 1 . Special, : W - HMIS Rating - S Health Flammability : 3 ,. - Physical hazard : .1' 'Prepared by : Air Products and Chemicals, Inc. Global EH&S Product Safety Department For additional information, please visit our Product Stewardship web site at ,. http//www.airproducts.com/productstewardship/ • : •• :- • ' •: ' : 7 . .•• • . . • :- ••; Air Products and Chemicals,lnc : ' . TOMCATS • , " Ernedco corn Vision Glo Exit Signs - ,Page 1 of 2 • ' Home.I Order Status I.ReglsterlView .Ji' Search item Number j - I 1-800-4 Traffic &Parking- Signs . __ I____ltl _ II __(__________________ $ Related I Machine Safety & Status IIi' Exit / Fire Signs Lock-Out & Electrical 'i" VISIOfl Glo Exit Signs Replacernei . Evacuation - Chemical & Right-Lo-rnow -. ,. . Two safety features in. one! Unique combination of photoluminescent Signs Exit / Fire 5 Safety Training 'and honeycomb high intenity, reflectivity provides an eye-catching & 3-Way' sign that glows for up to six hours after a power failure and Warehouse & Shipping constantly reflects light during an emergency. Professional glossy finished 'plastic with foam adhesive backing allows easy mounting in fast Exit & Fire - ' your,offlce or warehouse. Easily adheresto cement-block walls or TrafficSig Security Solutions WOOd: Subsurface-printed for long-lasting use. - pricin Si Pipe & Valve Marking '• - ' - -: Item No S220G Industr ai . 0, Tags interlorSigns Wording EXIT '1~ Decals Smoking Policy and Facility Size 8" -X 12' Color GRiEN ., lo First Aid & Protective Wear Material PLASTIC I , Custom Products .- - , •_1_ - Traffic Control Spanish & Bilingual UTT1 -Item No-S22011 • I - Wording EXIT I ' Regulation Resource Site I Size 8"X12" I L I Color RED Clearance & Web Specials . material -PLASTIC - r Product Descriptions iTN1fl o ernedco Originals • 4 Quote Request ____________ Item No S221G Wording EXIT 'With arrw right - Clicki to Customer Service Size 9" X 12". -- '• ' ' • . My Favorites -colol -GREEN- , - -- . ' . ,• Material- :pJC • Links JTITTIfl Item No 'S221R Wording EXIT with arrow right Size 9" X 12" - • , - *emedco' i-I'I Color RED • , -• IMEflhJI4SroIl1iNWO1uI - - Material"PLASTIC •- . - . • - -. . - 4--. . • . - -S. 4 .• 4 . I . ' - 4- - •• Item No S222G Wording EXIT EXIT with arrow left . * . - , - Size -9" X12" -' - ' , - . 0 • • - . Color GREEN . , - - ' . - -Material PLASTIC 41 - - - • - - 1• • • - ' . - . - Item No S222R 4 - .4-_*•_. - • . *5 - I. • 2 - I- 4 4ttp://www.einedco.com/prodGrouvAT.asp?d6pi%5Fid=3612&CC=N 6/20/2007 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# __"2S'1 HV# - L-j17' BP DATE 3 iL i07 Business Name Business Contact Telephone # Air Products and Chemicals, Inc. Randy Skow 0 760-929-6213 Project Address City State Zip Code APN# 1979 Palomar Oaks Way Carlsbad CA 92011- Mailing Address City State Zip Code Plan File# 1969 Palomar Oaks Way Carlsbad CA 92011- 071434 Project Contact Telephone # Craig Stephens (760) 929-6251 x The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT -HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards Flammable/Combustible !ids 7. Pyrophoncs 11.. Highly Toxic or Toxic Materials 15. None of These. lammable Solids 8. Unstable Reactives 12. Radioactives PART It: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3" floor, San Diego, CA 92101. Call (619) 338-2222 prior to the issuance of a building permit FEES ARE REQUIRED. Expected Date of Occupancy: 2007-08-01 YES NO Z 0 Is your business listed on the reverse side of this form? (check all that apply). 0 ED Will your business dispose of Hazardous Substances or Medical Waste in any amount? C9 0 Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? 00 Will your business use an existing or install an underground storage tank? 010 Will your business store or handle Regulated Substances (CalARP)? 0 0 Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? 0 CalARP Exempt Date Initials 0 CalARP Required Date Initials 0 CalARP Complete Date Initials PART Ill: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. YES NO 0C9 Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facts/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). 0 0 (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/; or contact the appropriate school district). 0 Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? 0 Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities: Briefly describe proposed project: Chemical processor - Chemical-storage I declare under penalty of pequry that to the best of my knowledge and b-te res ses made n re and correct. Al __________________ ____________ Name of owrir or Aulhorized Agent Signature of OwnW or A7uh-or,06 Age Date FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY -CLASSIFICATION: BY: DATE: I / EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD APCD C D APCD APCD REVIEW€ NAM 1 07 ____ _______________ 14 HM-9171 (04/07) County of San Dieoo - DPI-i - I4a7,rrIr,,c M,,tpth,k fliwknn 4105 Sorrento Valley Blvd. Klausbruckner& Associates San Diego, CA 92121 Tel: (858) 677-9878 Fax: (858) 677-9894 Air Products H=3/H'7 Storage Area 1979 Palomar Oaks Way Carlsbad, CA, 92011 Hazardous Materials Report. Rev 3.1 Date: June 15, 2007 •• Additional Info: