Loading...
HomeMy WebLinkAbout1985 PALOMAR OAKS WAY; ; CB921004; Permit5/y BUILDING P ER WI T Permit No: CB921004 10/22/92 15:16 . . '- . Project No':. A9202123 H Page 1 of . 1 - . - . - . / Development No: Job Address: 1985 PALOMAR OAKS-WY ' Suite: 9815 .10/22/92 0001 01 02 Permit Type: INDUSTRIAL. TENANT IMPROVEMENT . . C-PRMT-, 34?500 Parcel No: 213-092722,-00'. . Lot#: . . Valuation 76,897 Construction Type.: •.VN . . •. .. .. Occupancy. Group: B2 Reference#: . Status: ISSUED Description: 6600 ,,SF.WHSE.TO MFG + 363 SF . Applied: 09/22/92.. STORAGE --K W. MICROWAVE . . Apr/Issue: 10/22/92 -. .. Validated By:. CD Appl/Ownr .• GREAT DESIGNS REALTY ' •, ,,.714 827-5551 9557 DEBORAH STREET CYPRESS, CA 906- CONTRACTOR GREAT DESIGjSEA & 4 ic4JO . . 7,14 8275551 9557 DEBORAH ST . . OWNER : CAL PAL - CYPRESS, A 90 1985 P OA}b WY . PCARLSBD/A f09 \ \ Credits--- Fees: .I 039i0 Adjustments: .00 N jtal f-L) 00 Total Fees: 4,039.0f' ot nt2;- 564.00 Fee description A. n' Fee/Un*t Ex t fee Data uiling Permit., 536 INCORPORATED !: Check : Fee' .16.00 Enter "Y" to Autocaic cenp a > 1400'.00 Y C. F\ D. 0 1292.'00 * BUILDING TOTAL. ... .. -, . 3592'00. Enter IIH for Plumbing Issue Fee > •0 . . 20.00 1 Each Plumbing Fixture or Trap . >. . 2 . 7.00 • 14.00 Each Building Sewer . . > 1 15.00 . 15.00 * PLUMBING .TOTAL , . .. . . .• .- 0 - '49.00 -. Enter 'Y" for Electric Issue Fee. > - . •. . . . 10.00 Y .Three Phase Per AMP,- >. 700 , .. .50 350.00 6PANELS * ELECTRICAL TOTAL : . . • . . 0 - . . 360.00 Enter '1 for Mechanical Issue Fee> 0 15.00 1 Install Furn/Ducts. . ' - > , - 2 9.00. 18.00, Each 'Install/Reloc Appliane Vent > - . -, 1 4.50 4.50- * MECHANICAL TOTAL 0 38.100 FIN APPROVAL IN JYCE - - CITY OF CARLSBAD- 2075,11s Palmas Dr, Carlsbad CA 92009 (619) 438-1161,,," QK4i PERMIT APPLICATION . City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 I. PERMJI TYPE A - U Commercial U New Building U enant Improvement - B -ndustrial U New Building Tenant Improvement C - 0 Residential 0 Apartment 0 Condo 0 Single Family Dwelling 0 Addition/Alteratior Duplex 0 Demolition 0 Relocation 0 Mobile Home U Electrical 0 Plumbing Mechanical U Pool 0 Spa 0 Retaining Wall 0 Solar U Other__________ 2. PROJECT INFORMATION Address j4' Narest Cross Street J LEGAL DESCRIPTION o CICK BELOW IF SUBMJT1 LoAA& OA'°fr ° .oM.M A!PJ)Dl...i' No. Subdivision ll.ame/Number L- iuAP NO 35 PLAN CHECK NO. J Z ,,00 </- EST. VAL /'oS . 000 PLAN CX DEPOSIT VALID. BY b C- DATE_________________ 9399 09/22/92 0001. 01 02 C-PRMT 564.00 FOR OFFICE USE ONLY Unit :e No. 2 Energy Calcs W2 Structural Calcs 02 Soils Report 0 1 Addressed 4 2DISCRIP'TION OFWQPJ( /4jof PPtTi1lo'\j6 prev 0 ' . c'/.i .s SQ. FT. f) 1 # OF STORIES JYA - UJN 1AC1 PF311,(J (ii dillerent from applicant) NAME jp ADDRESS ,6tl4 oc-& CITY k-ft 14 C) STATE CA ZIP CODE DAY TELEPHONE() APPLICANT U C(I1tACTOR U AGENT FOR CONTHACTIJR OWIIER U AGENT FOR OWNR p CA NAME r Z ADDRESS [ ZIP CODE q200 ' DAY TELEPHONE (') PROPERTY OWNEUi NAME CAL (4C\L J). ADDRESS /Aa.. OA CITY STATE CA ZIP CODE q,..00' DAY TELEPHONE 6i) I4 - (DWF1DR ,, 9 :E.eo NAME E..Prr CITY C. STATE CA ZIP CODE jOb3o DAY TELEPHONE - 7- 55/ Relations, ora certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exemption: I certify that in the performance 01 the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE S. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden / of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant foruch permit to file a signed statement that he is licensed pursuant to the provisions of Con actor's 'cerise Lawpter 9,,commencj with Section 7000 of Division 3 of the Business and Professions Code) or that he i e p er a the bI4oj tl.alleged 4émption. Any violation of Section 7031.5 by any applicant for a permit subjects t ic ivi alty dollars [$500]). SIGNATURE f)J1) tJ)A1t / 12-'/ f 2— Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25598, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? YES NO Is the applicant oruture building occupant required to obtain a permit from the air pollution control district or air quality management district? EYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES WNO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF ThE OFFICE OF EMERGENCY SERVICES AND ThE AIR POLLUTION CX)N11tOL DIS'IlUCF. WNSThUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code). LENDER'S NAME LENDER'S ADDRESS APPLICANT CERTIFICATION I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARlSBAD AGAINST ALL LIABILITIES, JUDGMENTS (X)STS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. 0511k An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. - Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Build'Code). APPUCM#TS SIGNATURE 1) DATE: IC4, W,46.Aj ) I PERMITS. 6/15/89 TYPE: ITI JOB ADDRESS: APPLICANT: CONTRACTOR: OWNER: REMARKS: MH/KUMAR SPECIAL INSTRUCT: PERMIT# CB921004 DESCRIPTION: 6600 SF WHSE STORAGE - K W 1985 PALOMAR OAKS GREAT DESIGNS REALTY GREAT DESIGNS REALTY & CAL PAL LTD PHONE: INSPECTOR 4Ap DID NOT SAY WHAT TYPE OF INSPECTION OR/LEAVit A PHONE NUMBER**************************/4******* CITY OF CARLSBAD INSPECTION REQUEST FOR 12/23/92, TO MFG + 363 SF MICROWAVE WY PHONE: DEV PHONE: INSPECTOR AREA MC PLANCK# CB921004 0CC GRP B2 CONSTR. TYPE VN STR: FL: STE: 714 827-5551 714 827 5551 0 TOTAL TIME: --RELATED PERMITS-- PERNIT# TYPE AS920076 ASC CD LVL DESCRIPTION 14 ST Frame/Steel/Bolting/Welding 7:: STATUS ISSUED ACT COMMENTS " ,6ZAS _'.5btF4 7 CøfrifL7 (i.J) "i' ***** INSPECTION H 19Ys A*A Y'JM.- F°"— DATE DESCRIPTION ACT INSI COMMENTS 121092 Rough Combo AP MPC MACHINE SHOP AREA 121092 Rough Electric CO MPC SEE INSP NOTES 120892 Rough Combo CO TP PROVIDE APPROVED PLANS/CARD 120192 Exterior Lath/Drywall AP MPC 120192 Rough Combo AP MPC ASSEMBLY AREA CElL 112592 Interior Lath/Drywall CO MPC SEE INSP NOTES 111992 Rough/Topout P1 MPC PROGRESS INSP 111992 Rough/Topout CO MPC SEE INSP NOTES 111992 Rough Electric P1 MPC SEE INSP NOTES 111992 Rough Electric CO MPC SEE INSP NOTES 111692 Frame/Steel/Bolting/Welding P1 MPC CEILING GRID PERIMETERS 111692 Frame/Steel/Bolting/Welding AP MPC STORAGE SHED 111692 Rough Electric P1 MPC PROGRESS INSPECTION 111292 Frame/steel/Bolting/Welding PA MPC STORAGE SHED WALL 110992 Rough Combo. P1 MPC PROGRESS INSPECTION 110492 Ftg/Foundation/Piers AP MPC STORAGE SHED SLAB & FTNGS 110492 Rough/Topout CO MPC ISOLATE CU PIPES & NAILGRD 110492 Rough Electric P1 MPC CLNG & ROOF EQMTS 110492 Rough/Ducts/Dampers P1 MPC CLNG & ROOF EQMTS 102992 Interior Lath/Drywall AP MPC NEW WALLS @ T.I. AREA. 102992 Exterior Lath/Drywall -. AP MPC NEW WALLS @ T.I. AREA 102692 Frame/Steel/Bolting/Welding PA PK WALLS & ROOF FRAMING 102692 Rough Electric PA PK FINAL BUILDING INSPECTION c1VED JAN 0 6 1993 DEPT: BUILDING ENGINEERING IRE- PLANNING U/N WATER PLAN CHECK#: CB921004 DATE: 01/05/93 PERMIT#: CB921004 PERMIT TYPE: ITI PROJECT NAME: 6600 SF WHSE TO MFG + 363 SF STORAGE - KW MICROWAVE ADDRESS: CONTACT PERSON/PHONE#: IWNAR/714 827-5551 SEWER DIST: CA WATER DIST: CA ------------------------------------------------------ INSPECTED DATE BY: INSPECTED: 5/t9 APPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - COMMENTS: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: --c'kr 11I JURISDICTION: PLAN CHECK NO: SET: PROJECT ADDRESS: I95 Rtioma.r Oaks PROJECT NAME: KM,r-' T APPLICANT FILE COPY UPS. DESIGNER Ej The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building, codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. fl The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. fl The applicant's copy of the check list has been sent to: fl Esgil staff did not advise the applicant contact person that plan check has been completed. 11 Esgil staff did advise applicant that the plan check ha ' been completed. Person contacted: Date contacted: to)Ie( Telephone REMARKS: i') F ±L pIs rv± b i A.,,. • . - .- - - By: Enclosures: IL CORPORATION 1j DGA 0CM ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DI'EGO,.CA 92123 (619)560-1468 DATE: I DAPPLICANT JURISDICTION: Cl~ r- 1-6 IOC14CI CKER - DFILE COPY PLANCHECK NO: ajo CLPP SET: Ds DDESIGNER PROJECT ADDRESS: j- /fi-r PROJECT NAME: Ku) E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply E with the jurisdictipn's building codes whenrninor deficien- cies identified are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. fl The applicant's copy of the check list is enclosed for the L..J jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: ba- aII (eeI '-p LII Esgi.l staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: J Oav/g( Date contacted: ,c'//SflL Telephone []REMARKS:___ By: Enclosures: ESGIL CORPORATION ,oII 11GA S-6 JURISDICTION: ___Date plans received by plan checker:_______________ PLAN CHECK NO.:7/OD/ ufDate plan check completed: ,o/,5/gz.By: (./a.,e-, PROJECT ADDRESS: /18-S TO: bcr PLAN CORRECTION SHEEP FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. The plan check is based on regulations enforced by the Building Inspection Department. You may have other. corrections based on laws and ordinances enforced by the. Planning Department, Engineering Department or other departments. The items shown below need clarification, modification or change. All items have to be satisfied before the plans will be-in conformance with the cited codes and regulations. Per Sec. 303(c), of the Uniform Building Code, the approval of the plans does not permit the violation of anystate, county or city law. () Please make all corrections on the original (.7 Please indicate here if any changes have tracings and submit two new sets of prints, been made to the plans that are not a result and any original plan sets that may have been of corrections from this list. If there are returned to you by the jurisdiction, to: other changes, please briefly describe them and where they are located on the plans. Have changes been made to the plans not I resulting from this correction list? Please check. To facilitate checking, please identify, next ___Yes No to each item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. This tt-.e re4/I51?t ,e/y, , p( L.c)I1Ii1 4 51 5 rc-*" 5 /iLd 77.r7,7cc c-h,s 1i iol If g uee d,'s''d A?'? ,%/Q/ ..i 4- 4t44d A 1L c-.4,d /iere/ flu 7%e L on thL 4--Ae 1r. Wo// (pL(- 7/ 5-1q Pa vISA ifK rr1l',L prje-/7ns a 7, 7% / - re- alu P- ir p. 77,j' zddi 'i'-i rp re &dd, Ii n g'7' R,r re Wed -h- b u / /di,71 Prove. i'lt# i-//i 16/e ' f'1 '/ 5/'i?$ ,_7171 7 Oir F-are Nr.iL. rV?'f.. a / ELECTRICAL PLAN CORRECTION SHEET .nmlsDlcnoN:______________ PMZ: I ,I 921004- sEr:1t PLAN E: _CHUCK MENDENHALL DAlE:_ I Cu flot crk c ôk m 4e. ob)ls VIA L cy ec ô ' c Pc c cccx -c (cic o(o* co- e or c(\Cr c\c1cni 0' cg T côieJ dLke C\VCtck oocs excrL *V oc oce. Am p wax 17- e. Xvce oock c -K-04 +0 r:-~ O #L' $ Pcoid ex' I ~ 4cnf -'s- onIA ___ Co tAc, J QY 4*e\&1 t'./ O f (ø0c (ed \1 +LOO OucCe ___ ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: t 1 -ICT JURISDICTION: CARLSBAD LAEEiER DFILE COPY PLAN CHECK NO: d1... 100 -4 SET: .I cups [J-DESIGNER PROJECT.ADDRESS: j Cl 5 PI,,nici,r oer lks PROJECT NAME: 4(vJ_M,'crwcue.—rT fl The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply LI with the jurisdiction's building codes when minor deficien- cies'identified are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. ri The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the Jurisdiction to return to the applicantcontact person. The applicant's copy of the check list has been sent to: Dc bicJcICIL4L49 Goiick I4r+ • Esgil staff didnot advise the applicant contact person that plan check has been completed. El Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # []REMARKS: c1 By:,(ittl- ESIL CO i2rGA 21& TION Enclosures: 'I PIN CORRECTION SO EET TENANT DWVT pj( caEcK No.: —9<-;A-- L4 Date plans received by jurisdiction: JURISDICTION: CARLSBAD Date plans received by Esgil Corporation: Date initial plan check completed: 't - By: PROJT DATA - Applicant contact person: Tel. cQ757c7 J]1DDIG USE:M f. fo R1 TYPE OF CONSTRUCTION: /Il ACTUAL AREA:/- ALLOWABLE AREA: BEIt: iiJ!C SPRINKLERS: OCCUPANT 'LOAD: irJ, FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or, other departments. Code sections cited are based on the 1991 UBC. The circled items listed need clarification, modification or change. All items must be 'satisfied before the plans will 'be in conformance with'the cited codes and' regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the' violation of any state, county or city law. To si,eed uD the recheck Drocess. note on' this list (or a copy) where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked trn 'list when you submit the revised plans. NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEM NE)ING CORRECTIONS WERE LIST NO. 41 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1991 UBC 1. pleas e4 make all corrections on the original 1/. On the first sheet of the plans indicate: tracings and submit two new sets of prints, to: ( Type of construction of the existing building, present and proposed occupancy classifications Esgil Corporation, 9320 Chesapeake Drive, of the remodel area and the occupant load of Suite 0208, San Diego, CA 92123, the remodel areas and the floor where the (619) 560-1468. tenant improvement is located. j. Please make all corrections on the original iA. Provide a note on the plans indicating if -any tracings and submit-two new sets of prints, to: I hazardous materials will be stored and/or used within the building which exceed the The jurisdiction's building department. quantities listed in UBC Tables 9-A and 9-B. Indicate on the Title Sheet of the plans, the 13. A complete description of the activities and name of the legal owner and name of person processes that will occur in this tenant space responsible for the preparation of the plans.. should be provided. A listing of all Section 302(d). hazardous materials should be included. The 4 zj. Each sheet of the plans must be signed by the materials listing should be stated in a form that would make classification in Tables 9-A person responsible for their preparation, even and 9-B possible. The building official may .though there are no structural changes. require a technical report to identify and Business and Professions Code. develop methods of protection from hazardous materials. Section 901(f). Plans and calculations shall be signed by the California state licensed engineer or architect 11/. If control areas are used for exceeding the where there are structural changes to existing / exempt amounts of hazardous materials from buildings or structural additions. Please ( Tables 9-A and 9-B, they shall be constructed include the California license number, seal, of not less that required for a one-hour date of license expiration and date plans are occupancy separation. Section 404. signed. Business and Professions Code. / The number of control areas within a building fi. Provide the correct address and suite number of used for retail/wholesale stores shall not tenant space on the plans. Section 302(d). exceed two; the number of control areas in buildings with other uses shall not exceed 7. Provide a note on the site plan indicating the four. Footnote 1, Tables 9-A and 9-B. previous use of the tenant space or building being remodeled. section 302. S1t' 71. f/c,'r a.rect e.i -1' U leio At e. (-'-. O2?) l. / The aggregate quantity of any hazardous materials "in use" and "in storage" shall not S When the character —f the occupancy or use exceed the quantity listed in Tables 9-A and changes within a building, the building must be 9-B for "storage". Footnotes 2 and 3, Tables made to comply with current Building Code 9-A and 9-B. requirements for the new occupancy. Please provide complete details to show the building Provide a statement on the Title Sheet of the with comply. Section 502. 1 plans that this project shall comply with Title 24 and 1991 UBC, UNC and UPC and 1990 9/. UBC Section 304 requires the Building Official NEC. 'I to determine the total value of all construction work proposed under this permit. . Provide a full dimensioned floor plan showing The value shall include all finish work, the size and use of all rooms or areas within painting, roofing, electrical, plumbing, the space b& improved or altered. Draw the heating, air conditioning, elevator, fire plans to scale and indicate the scale on the extinguishing systems and any other permanent plan. Section 302(d). equipment. Please provide a signed copy of the . designer's or contractor's construction cost 1,9. Indicate the use of all spaces adjacent to the estimate of all work proposed. . 1 area being remodeled or improved. l6. Provide a plot plan showing the distance from 2. Show any existing fire rated area separation the building to the property lines and the f walls, occupancy separation walls, demising location of tenant space (or remodel) within walls, shafts or rated corridors. Identify the building. and provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor- ceiling assemblies or roof-ceiling assemblies. 8/4/92 2 2.1. Identify existing walls to be removed, . In buildings having floors and roofs of wood existing walls to remain and proposed new / frame construction, other than dwelling or walls. Identify bearing walls, non-bearing hotel occupancies, draft stop the area between walls, and shear walls, the ceiling and roof above so that no 23. Show safety glazing in the following concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space locations, per Section 5606(d): has sprinklers, then 9,000 s.f. and 100 L.F.). Where the nearest edge of glazing is Section 2516(f). within a 24-inch arc of either side of a / door in a closed postion (unless there is ,O. Storage areas exceeding 1000 sq. ft. in an intervening wall between the door and ( connection with wholesale or retail sales the glazing or if the glazing is 51 -0" or shall be separated from the public area by a higher above the walking surface). one-hour occupancy separation. If the entire Glazing greater than 9 square feet with building has an automatic sprinkler system, the bottom edge less than 18" above the then the occupancy separation need not be floor and the top edge greater than 36" provided. Section 702(c). above the floor (unless the glazing is / more than 36" horizontally away from 11. An automatic sprinkler system shall be walking surfaces or if a complying / installed in rooms used by the occupants for protective bar is installed), the consumption of alcohol and in accessory C. Glazing in shower and tub enclosures uses where the total area of such unseparated (including windows within 5 feet of tub rooms and assembly uses exceeds 5000 square or shower floor). feet. Section 3802(c). 24. f Provide a section view of all new interior partitions. Show: 32. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the Type, size and spacing of studs. Indicate physically disabled. See the attached gauge for metal studs. Specify correction sheet. Title 241, Part 2. manufacturer and approval number or indicate "to be ICBO approved". 13, The width of the required level area on the Method of attaching top and bottom plates ( side into which doors swing shall extend 24 to structure. (NOTE: Top of partition inches past the strike edge for exterior doors must be secured to roof or floor framing, and 18 inches past the strike edge for unless suspended ceiling has been designed interior doors. Section 2-3304, Title 24. for partition lateral load). ( Wall sheathing material and details of 314. Specify lever-type hardware for passage doors attachment (size and spacing of f on floors accessible to the disabled. Section fasteners). 2-3304, Title 24. Show height of partition and suspended ( ceiling, and height from floor to roof 3. If both sexes will be employed and the number framing or floor framj,ng. of employees exceeds four, provide separate (Ae....., A'Ir1 rorY ) toilet facilities for men and women. If "both 25. Provide notes and/or details to show that the sexes will be employed and the total number of floor and wall finish in toilet rooms are employees will not exceed four", and only one surfaced with a smooth hard non-absorbent restroom is provided, note the words in material extending five inches up the wall., quotation above on the floor plan. Section Similar surfacing shall be provided on the 705(c). walls from the floor to a height of 4 feet around urinals and within water closet 3,6. A -hour occupancy separation is compartments. Section 510(b). / required between occupancy and - the occupancy. Table 5-B. 26. Note on the plans: "All interior finishes must ( comply with Chapter 42 of the UBC". Specify 3ft. Ducts penetrating occupancy or area separation "Class flame spread rating (minimum) ( walls must have fire dampers. Section 4306 for ." (j). 2f7. Note on plan that suspended ceilings shall . In areas where the occupant load exceeds -, comply with UBC Tables 47-A and 23-P. two exits are required. See_________________ Table 33-A. 2. In buildings having floors and roofs of wood frame construction, other than dwelling or 39. Provide an exit analysis plan (may be 8 1/2" x hotel occupancies, draft stop the area between 11" or any convenient size). the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no 4Cr. Exits should have a minimum separation of one- horizontal dimension exceeds 60 L.F. (if space ( half the maximum overall diagonal dimension of has sprinklers, then 3,000 s.f. and 100 L.F.). the building or area served. Section 3303(c). Section 2516(f). 7/8/92 3 The maximum number of required exits and their / required separation must be maintained until egress is provided from the structure. Section 3303(a). Rooms with more than 10 occupants may have one / exit through one adjoining room. Revise exits to comply. Section 3303(e). 43. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 3314 (a). 41. Show that exits are lighted with at least one / foot candle at floor level. Section 3313(a). Show the locations of existing exits from the I building and show the path of travel from the remodel area to the existing exits. 06.Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOC}D DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3c). Ioc.-k flo - 47'. Exit doors should be a minimum size of 3 feet ( by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(f). 4j. Exit doors should swing in the direction of / egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3304(b). Applies to door(s)__________ 4. Regardless of occupant load, a floor or landing f not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access). Section 3304(i). Sc1. Doors should not project more than 7 inches I into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). sj. Provide panic hardware in Group A,E,H-1,H-2,H-3 I and I occupancies. Chapter 33. 54. Double acting doors are not allowed when I serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection / to the exterior of the building. Interruptions by an intervening room is not permitted. Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. 5. Corridors and exterior exit balconies serving ( 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection. Corridors serving less than 50 occupants may be a minimum of 36 inches in width. Section 3305(b). 5. When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction. Show compliance or clearly show on plans which of the following exceptions has been satisfied: Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. Exterior sides of exterior exit balconies. C. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. d. Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet in height need not be fire resistive, provided they are constructed in accordance with Section 1705 and are not more than three fourths of the floor- to-ceiling height. Section 3305 (g). I 4. Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. 5/. Section 3305(g), Exception 5 does not apply to coon corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). 4. Section 3305(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels. 5/28/92 4 6/. If non-rated corridors are used per Section / 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: i. Corridors are non-rated per Section 3305(g), Exception S. Smoke detectors shall be maximum 30' on center. Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. 6j. If a tenant space utilizes Section 3305(g), / Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. 6. Clearly show where the non-rated corridor I system terminates and a rated corridor system commences. 6/. One-hour fire-rated corridors shall have interior door openings protected by tight- fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic- closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305(h). 65 Total area of all openings, except doors,, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed glazing listed and labeled for a fire- protection rating of at least 3/4-hour. Section 3305(h). 6. Show rated corridors, lobbies, reception or foyers cross-batched on the floor plans. 6fr. Provide a complete architectural section of the corridor, or.'exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g). 68 1 . Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor ceilings. Combination fire/smoke dampers are required at duct penetrations of rated corridor walls. Section 4306(j). 6. If a room with an exhaust fan has a door / 'opening into a rated corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)l. 79 If building exceeds two stories and has an / elevator opening into a rated corridor, show ' how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. Section 3305(j). li. If a second door is provided at the elevator / entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort. Section 5106. New provisions in chapter 43 of the 1991 UBC require special treatment of penetrations at fire-resistive assemblies. Provide typical details on the plans showing how the fire- resistive integrity will be maintained at the following conditions (Include the manufacturers' names and ICB0 numbers (or equal) for any sealant): A. THROUGH- PENETRATIONS (through the entire assembly): Fire-resistive bearing walls and/or walls requiring protected openings shall have penetrations protected with through- penetration fire stops having an F- rating, I-rating or 'complying with UBC Standard 43-1, depending on their locations, sizes and combustibility. Fire resistive floor/ceiling assemblies shall have penetrations protected with through-enetration fire stops having and F-rating, I-rating or complying with UBC Standard 43-1, depending on their sizes, combustibility and whether the penetrations are in walls above. B. MEMBRANE-PENETRATIONS (through only one side of an assembly): Fire-resistive walls (whether bearing or not and whether requiring fire protected openings or not) shall have penetrations protected with membrane-penetration fire stops having an F-rating or complying with UBC Standard 43-1, depending on their size and combustibility. Limited steel electrical outlet boxes (not exceeding 16 sq. in., nor more than 100 sq. in. for any 100 sq. ft. of wall) require no protection. Fire-resistive ceilings shall have no penetrations, except for noncombustible sprinkler pipes and steel electrical outlet boxes as described above. NOTE: The plans should indicate the various fire-stop ratings required for all penetrations. 7. Provide a note on the plans stating I "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 4304 and 4305". 8/4/92 ' 5 7. Provide evidence of Health Department approval / (for restaurants or for tenants using X-ray equipment). If nonflammable supply cylinders for medical / gas systems are located inside buildings, show how they comply with UBC Section 702(c)4. Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. Indicate wiring method, i.e. EMT, metal flex. Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314 of the 1991 UBC, provide two sources of power to exit signs and exit illumination. Provide receptacle(s) within 25' of HVAC units. UMC Section 509. Provide multiple switch lighting controls per Title 24, Part 6. MECHANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. () Provide mechanical plans showing existing and proposed HVAC equipment, ducts an access to equipment. Detail access and working clearances to HVAC equipment. 89 Detail disposal of main condensate drainage from air conditioning units. (UMC Section 510) -Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space. (UMC Section 1205) Fire rated corridors are not to be used to convey -air to or from rooms. UMC Section 1002. PIINSING Provide gas line plans and calculations, 1' showing pipe lengths and gas demands. UPC Section 1219. EQ Provide drain, waste and vent plans. Provide-water line sizing calculations. UPC Section 1009. %. Detail how floor drain trap seal is to be .' maintained. UPC Section 707 (floor drain trap priming). Show P .& T valve on water heater and detail / drain line route from P & T valve to the exterior. UPC Section 1007(e). Show -1/4" per 12" slope on drain and waste lines. UPC Section 407. ,9. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 605. 99. Note on the plans that new water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2, associated flushometer valves, if any, shall-use no more than one gallon per flush and shall meet performance standards established by the American National Standards -Institute Standard A112.19.2. H & S Code, Section 17921.3(b). ENERGY Provide complete energy design calculations, including all existing design and new energy design for this building. See attached non- residential energy design checklist. 19, For remodels in-an existing conditioned space, ( show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards. CITY OF CARLSBAD SUPPLEMENT 10/. Floor drains must have auto-prime (City Policy). - 10 . A grease interceptor is required. Show details complying with City Policy 83-34. 104. Roof mounted equipment must be screened and roof penetrations -should be minimized (City Policy 80-6). 8? / N crk, no a ' 7 47 / $ 7 C. — JOIffa IC i•i 'U ,4AJ Ij 4(:c27''ç 8/10/92 6 Condensate drains must connect to a wet trap (dry traps are not permitted). (Memo 1/14/83). 1Q16. Show fans are duct type; City Policy does not / permit ductless fans. 7107. No wiring is permitted on the roof of a t building and wiring on the exterior of a building requires approval by the Building Official. (City Policy) 108. All roof-mounted euipment shall be concealed from view. Provide structural detailing for the screening. All panel boards shall have a minimum 100 amp ( rating 0r approved by the Building Official. Only tank-type water closets that use an average of 1.6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of 1 gallon of water per flush or less shall be installed in new construction. These provisions shall apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. MISCELLANEOUS Please see additional corrections or remarks that follow. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e;, plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes ___No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any. questions regarding these plan check items, please contact__________________ at Esgil Corporation Thank you. Enclosures: 2 P/-ce e-r-c_ 7L1 1-lie- cM1:?t- r'.re'c,e. re 8/10/92 • • • 7 M&MacAL, P1mG, EMEWr PLAN CORRECTION 10_ JURiSDIc1!ICN: LA1145 131t4a DATE:/ — o _ / ] GLEN ADAMIX PLAN CH= NUMBER: ° PLAN (_E(1 D IAJ — 746 P'1 ,1AJ 5 3 /1D 'J /kl 6 o 4o 4 c c- /6-) 5 L #47' 0 *J /2t.'c L#j y / ___ As 7rLd 29 Sc "j Z -3Zf (cx) , too 7i f 72i / L o / 4 ii 5/6 -3 -J ':, US 4f&) (-J S .g4 It r 57 1--174 Q / - 7- ci 5. , 1 / , $ 7_t4 -. h, ,- 7'/\J / /L) /d.4i 3 -• ,o / t' a - 4r AV SO.,q c d- 4,, g,, /42 o 'o ' XD Z s, ' J 4 i.i 3x#' s r / &' C0 0i Jo , 7/a i SA r a 61;uv crk. oo AI 7'd i& c y .j I, r, ,i 44 ci 7 eV 4 AJ Q Sf 4 AiLfQC c-1,3 A 'u ad )C 4.', A 4f /.i / Al 7 0 4.) -7;,, •,4p_(_J IIJ J$/44i O# 5 V5 14e11 S ,-+'uC. r 401 r,-,. s-iz. £ .'1'4ia FG- / / 4 au w er U 4s (fl4s. PAM: SEE: DAlE:_____ Show location of Service(s). Ile- NEC 110-16, 230-2. Specify dimensions of equipment rated 1200 amps or more. NEC 110-16(c). 20. Provide the required access and entrance to working space for equipment rated 1200 amps or more and over 6 feet wide. NEC 110-16(c). SE 6F-LOLL) Show location of all panels, load centers, switchboards, and transformers. NEC110-16, 240-24, 300-21. 22. Provide the required working space about electrical equipment. NEC 110-16. )Submit complete panel schedule(s).QIJ0I Provide overcurrent protection on the 7 secondary side of transformers. NEC 240- 21 Ex., 384-16(d). Provide required transformer ventilation. ' NEC 450-9. 26. Provide receptacle(s) within 25 feet of HVAC equipment. UNC 509. Provide the required 20 amp 1200 VA sign circuit(s) and receptacle(s). NEC 600- 6(b)(c). S Provide "uniform" pattern lighting within sight of multiple switch lighting controls. CAC Title 24, 5319, 29. When two or more exits are required, show exit signs on the lighting plan(s) at all required exits and specify them as being self-luminous or having a second power source (battery or generator). NEC 700- 16/UBC 3314. Gserves In all occupancies where the exit system 100 or more occupants, provide a minimum of 1 footcandle emergency illumination at the floor level and specify a second power source (battery or generator). NEC 700-16/UBC 3313. SaL speed up the recheck process, note on is list (or a copy) where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised nanc. 110 PLAN CHECKER: CHUCK MENDENHALL Submit complete electrical plans reflecting the full extent of work to be performed, including but not limited to the following as applicable. Submit complete service and feeder one- line diagram. NEC 215-5. Show the Available Fault Current (Isc) from the Utility Co. and at equipment where the Isc exceeds 10,000 amps. Show the ampere interrupting capacity (AIC) ratings of service and subservice equipment. NEC 110-9, 230-65. 5. Show the method used to limit fault currents to 10,000 amps on branch circuits. Show fuse letters if used (i.e., JJN, A3T, LPN). co I.iEu. .)Pp.3E-L Show fuse/breaker size(s). NEC 240-6. Show each building disconnecting means. NEC 230-84. Show conduit and wire sizes. Specify wire type (AL or CU) and insulation (i.e. THWN). NEC ART 310. /1. Show the approximate length of feeders. Show the grounding system required for each building, structure, or service. NEC 250-24, 80(a), 81(c). Show the "nearest electrode" used for each transformer secondary ground system (i.e., bldg. steel, cold water pipe). NEC 250-26(c). Show the grounding electrode conductor / size and wire type (AL/CU). NEC 250-94. Submit load calculations. Include long 7 continuous loads (LCL) and largest motor loads. NEC ARt 220. Show/Identify new loads proposed for the / existing equipment. Indicate main service size and total load. 17. Specify wiring, methods (i.e., EMT, Metal Conduit). Any questions on electrical corrections please contact the plan checker shown above at Esgil Corporation at (619) 560-1468. Thank you. 09/04/92 TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction is bcwc _________________________ Plan Check No._________________ References to section numbers with prefix "2" are to Title 24, California Code of Regulations, Part 2 (California Building Code). Prefix 113" is for Part 3 (California Electrical Code). Prefix "5" is for Part 5 (California Plumbing Code). Exemptions claimed for any item shall be requested in writing.and shall include all data needed to determine "unreasonable-hardship" as described in Section 2-422. (S :IT:ED:nRrELOPM~~a~U A)oie— -. c-k c- d. If no landing is provided, the slope of flared sides shall not exceed 1 in 12. HANDICAPPED PARKING SPACES• 2-7103(d) Provide handicapped spaces. 2-7102(b) Space shall be so located that handicapped persons are not compelled to wheel or walk behind parked cars other than his/her own. 2-7102(c) C. Parking space shall be a minimum of 9 ft.x18 ft. with adjacent marked 5 ft. loading zone. Double space shall be 23 ft. wide. Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle. 2-7102(c). Maximum slope of parking surface in any direction shall not exceed 1/4" per foot. 2-7102(e). Parking space(s) shall be identified with the International Symbol of Acdessibility on ref lectorized sign affixed to post or wall, and also duplicated on parking surface (symbol to be 36"x36" and painted at the back of the parking stall). 2-7102(1) 1. Entrance to parking area (or at each stall) shall.have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away. 2-7102(f) If covered parking is provided, then a reasonable portion of the total number of stalls reserved for the disabled shall also be covered. 2-7102(a) Entrances to and vertical clearances within accessible levels of parking structures shall be 8 ft. 2 in. to any structural member, duct or pipe. 2-1102(g) 2 CURB RAMPS Curb ramps shall be located wherever pedestrian path crosses curb. (2- 7103(a)) Curb ramp shall be 48" mm. width (2- 1103(b)) with maximum slopeof 1 in 12. 2-7103(d) C. A level 48" mm. depth landing is required • at top of curb ramps over entirecurb ramp width. 2-7103(d) e. Surface is to be slip resistant and a contrasting finish from adjacent sidewalk. 2-7103(f) f. Border markings shall be 12" wide of 1/4"xl/4" grooves, 3/4" apart, located at top and sides. 2-7103(h) 3. WALES Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-7101(a) Walks sloping greater than 5% (1 in 20) must comply with . ramp requirements of Sec. 2-3301. 2-3325(c) Walk width shall be 48" minimum, and shall have slip-resistant surfaces. 2-3325(a) The maximum cross slope shall not exceed 1/4" per foot. 2-3325(a)3 Gratings are not allowed whenever possible. 2-3325(b) f.. At each gate or door a 6011x60" level area is required when the gate swings toward the walk. 2-3325(e) g. A 481lx44" deep level area is required when the gate swings away from the walk. 2-3325(e) h. A 24" clear space is required at strike side of gate or door. 2-3325(e) PEDESTRIAN RAMPS A path of travel with a slope greater than 1 in 20 shall be considered a ramp. 2-3307(a) The maximum slope shall be 1 in 12. 2-3301(c.1) The width shall be 48" minimum. A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more. Group R Occupancies may be 36" when the occupant load is 50 or less. 2- 3307(b.1) The surface of ramps shall be slip- resistant. 2-3307(g) A 60" intermediate landing is required at maximum elevation change of 30" and 72" landing at each change of direction (over 30 degrees). 2-3307(d.1) Landings are required at top and bottom of ramps. 2-3307(d.1) Bottom landing -shall be minimum of 72" in the direction of travel. Fig. 2-33- 1A Top landing shall be 60" x 60" minimum. 2-3307(d.1) When door swings onto top landing, minimum depth of landing required is door width plus 42". 2-3307(d.l.) Top landing shall have 60" min. width when door swings onto the landing, with 24" on strike side of door at exterior ramp, or 18" at interior ramp. 2-3307(d.1) Ramp handrails are required on each side of ramp, when slops exceeds 1 in 15. 2- 3307(e.1) 1. Ramp handrails shall be continuous, located 30"-34" in height above ramp surface, with 12" extensions beyond top and bottom, and the ends returned. 2-3307(e.1) m. Handrails shall be 1-1/4" to 2" cross section, spaced minimum of 1-1/2" from wall. 2-3307(e.1) n. A 2" high curb or wheel guide rail centered 31* ± 1" above ramp surface is required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length. 2-3307(h.1) SPECIAL ACCESS LIFTS Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial 'Relations, Division of Occupational Safety and Health. 2-5107(a) The lift platform shall be of sufficient size to accommodate a wheelchair (301lx4811). 2-5107(a) There shall be a level and clear floor area or landing (60"x60") at each level for access to the lift. 2-5107(a) HAZARDS a. Provide 80" headroom from walkway surface to any overhanging obstruction. 2-3326(b) b. Headroom Of So" minimum shall be maintained for walks, corridors, aisles, etc. 2-522(f) c. Protruding objects with leading edges between 27" and 80" above finished floor shall not protrude more than 4" into walks, corridors, etc. 2-522(f) d. Free standing objects mounted on posts between 27" and 80" above the floor may project a maximum of 12". 2-522(f) e. Abrupt changes in level exceeding 4" adjacent to walks, except between walks and adjacent streets or drives, shall be identified by 6" high warning curbs above walk surface. 2-3326(a) J . ENTRAJCES, DOORS, VESTIBULES AND CORRIDORS ,I. All primary entrances to buildings shall ( be accessible to the handicapped. 2-3301(f) All required passage doors shall have 32." clear opening at 90 degrees (36" door). 2-3304(f) At least one of a pair of doors shall meet the minimum 32" clear entrance width requirement. 2-3304(f) 41 Threshold shall be no higher than 1/2" above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more than 1/4". 3304(1.1) Exterior level landing may slope up to ( 1/4" per . foot in any direction for surface drainage. 2-413 f. oor hardware shall be of thelevgr or push type, mounted 30" to 44" above the floor and be operable with a maximum effort of 8.5 lbs. for exterior doors and 5 lbs. for interior doors. 2-3304(c), 2.- 3304(1.2) e lower 10" of the door shall be of mooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304(1.3) h. Building entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan. The symbol shall be a white figure on blue background. 2-522(b) At turnstile, provide an access gate, 32" clear width opening, within 30 feet of turnstile. 2-3304(1.4) j. There shall be a clear area on each side / of door, 60" deep in direction of door 'swing and 44" deep in opposite direction Of door swing. 2-3304(i.1) kL Width of clear area on the swing side of i. Approved stairway identification signs I the door shall extend 26" past strike shall be located at each floor level in jamb for exterior doors and 18" past all enclosed stairways in buildings two strike jamb for interior doors. or more stories in height. The sign 2-3304(i.1) shall identify the stairway, indicate whether there is roof access, the floor level, and the upper and lower terminus of the stairway. The information shall be presented using raised Arabic numerals ]/. The space between two consecutive doors and raised braille symbols which conform ( (vestibule) shall provide a minimum of to Section 522(b)3. The sign shall be 48" clear dpth between the open door located approximately 5 feet above the and a second closed door.Doors in a floor landing immediately adjacent to the series at a vestibule shall swing in the door on the strike side. Signs shall same direction, or away from the space comply with requirements of U.B.C. between them. 2-3304(1.1) '•• Standard-No. .33-2. For corridors over 200 feet 'long, see l. ELEVATORS special requirements of Sec. 2-3305(b)2. a. Provide clear inside elevator car FLOORS dimensions as required by U.B.C. Section 5103(d) 6 and Title 24 2-5103(d.1). a. Floors of a given story shall be a coon level throughout or shall be 1. At least one elevator in buildings 4 connected by pedestrian ramps, passenger or more stories in height: 80" by elevators, or s pedal access lifts. 54", with a 62-inch side slide door. 2-522(e) Applies only to: high-rise buildings, A/ElI occupancies, State-owned S. STAIRWAYS buildings, residential care homes, ' hotels, motels, apartments and NO'lI: Only applies where disabled access is condominiums. provided or required to other levels. 2. Elevator in buildings more than two Treads shall have smooth, rounded stories or buildings where disabled exposed edges and be slip resistant. 2- access is required to upper level(s): 3306(s) 68" by 54", with a minimum clear door width of 36". Nosing shall not project more than 1-1/2 inches past face of the riser 3. Elevators other than in (b) above below. .2-3306(s) serving less than 50 occupants shall have a minimum inside platform of 4 Risers shall be sufficiently solid.. feet 6 inches by 4 feet 6 inches and a 2-3306(s) ' minimum clear door width of 36 inches. The upper approach and lower tread of b. Raised Braille markings and Arabic each flight of stairs shall be marked numerals are required on control buttons with a contrasting colored :strip 2" in and door jambs. 2-5103(d.1) width. 2-3306(r) _____ SM]iAY.I FACThTTTh .e. On exterior stairs, each tread shall be marked as noted above. 2-3306(r) TOILET FACILITIES ACCESS ( 34 f. Handrails are required on each side of a. When located on accessible floors, stairway. 2-3306 sanitary facilities shall be made accessible to physically handicapped. g. Handrails shall be located 30" to 34" above nosing,extend 12" beyond top riser and 12" plus tread, width beyond bottom Door-ways shall have 32" minimum clear nosing and returned to wall/newel post. opening width. 2-511.1 2-3306(j.1). There shall be a level area with 60" h. Handrails shall be 1-1/4" to 2" in clear depth in the direction of the door gripping' cross section and 1-1/2" clear swing, and a level area with 64" clear of wall. 2-3306(j.1) 'depth in opposite direction of door swing. 2-511;1(a) () MULTIPLE ACCOMMODATION TOILET FACILITIES a. Provide clear area 60" diameter x 27" high - or, clear space 56" x 63" x 27" high. 2-511.1(a) Doors (other than handicap. compartment) are not to encroach more than 12" into above mentioned clear space. 2-511.1(a) Provide a 28" clear space between water closet and fixture or 32" clear space between water closet and wall. 2-511.1(a) A 48" long clear space is required in front of water closet. A 60" clear space is required when the toilet compartment has a side door. 2-511.1(a) Water closet, compartment door to provide 32" clear width for end entry and 34" clear-width for side entry. Door to be self-closing. 2-511.1(a) 1). SINGLE ACCOMMODATION TOILET FACILITIES a. Water closet shall be located 28" from a fixture or 32" from a wall. 2-511.1(a) Minimum clear space in front of water closet shall be 48". 2-511.1(a). In an existing building, a single accommodation toilet facility may have a space 36" wide x 68 " long in front of water closet. 2-511.1(a) (9 RJ3 BARS AT WATER CLOSET One at side 42" long extending 24" in front of water closet; one at rear 36" long centered on water closet; both mounted 33" above floor. Where a tank- type toilet is used, grab bar may be as high as 36". 2-511.1(a) Bars shall be 1-1/4" to 1-1/2" in diameter with 1-1/2" clearance to wall. 2-511.1(a) C. Bar fasteners. and mounting support shall be able to. withstand 250 lbs./ft. in bending, shear and tension. 2-511.1(a) 59. WAR CLOSET . Height of water closet seat shall be 17" to 19" above floor. 5-1502 Controls shall be operable with one hand, and shall not require. tight grasping, pinching or twisting of the wrist. 5-1502 Controls for the flush valves shall be mounted on the wide side of toilet areas, no more than 4.4" above the floor. 5-1502 The force required to activate controls shall be no greater than 5 pounds force. 5-1502 ' URINALS .\1.11 . . - ()Where urinals are provided, the rim of at least one shall project ? from the wall and be located 17" maximum above floor. 5-1503(a) The force required to activate the flush valve shall be 5 lbs. maximum and located 44" maximum above floor. 5-1503(b) çl. Provide 30" x 68" clear floor space f forward approach. 2-511.1(b)'11 Provide 30" x 48" clear floor space for forward approach. Said clear floor space may include knee and toe space under lavatory described below. 2-511.1(b) Provide clear space beneath lavatories 29" high by 30" wide by 8" deep at top and 9" highby 30" wide by 17" deep at bottom from front of lavatory (toe space). The maximum counter surface height should be 34". 5-1504(a) Hot water and drain pipes under lavatories shall be insulated. 5-1504(b) Faucet controls and operating mechanism (operable with one hand) shall be of the type not requiring tight grasping, pinching or twisting of the wrist (such as lever-operated) and an operating force not exceeding 5 lbs. 5-1504(c) If self-closing valves are used, they shall remain open for at least 10 seconds. 5-1504(c) SMILET ROOM ACCESSORIES Mirror bottom edge shall be located 40" maximum above floor. 2-511.1(b) Toilet tissue dispensers shall be mounted within 12" from the front edge of toilet seat. 2-511.1(b) Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc.) shall be within 40" of floor. 2-511.1(b) 19 SANITARY FACILITIES IDENTIFICATION a. On doorways leading to sanitary facilities the symbols to be provided are 12" Equilateral triangle for men, 12" 'diameter circle for women, and 1/4" thick, centered on door, 60" high and contrasting color. Unisex facilities shall be identified by the circle with the triangle superimposed within the circle. 2-511.1(a) BATHING FACILITIES One such facility shall comply when provided for the public, clients or employees. 2-511.1(a) Shower compartment shall be 42" wide, 68" deep, with a 36" wide entrance. 2-511.1(a) Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec. 2-51la-9, 5-1505 and 5-1506, i.e., folding seat, flexible shower hose, etc. 21. DRINKING FOUNTAIN a. Drinking fountains shall be within alcoves. The alcove shall be not less than 32" wide by 18" deep. 2-511.1(c) b. When the enforcing agency determines that it would create an unreasonable hardship to locate the water fountain in an alcove, the water fountain may project into thepath of travel, and the path of travel shall be identifiable to the blind as follows: The surface of the path of travel at the water fountain shall be textured so that it is clearly identifiable by a blind person using a cane. The minimum textured area shall extend from the wall supporting the water fountain to 1 foot beyond the front edge of the water fountain and shall extend 1 foot beyond each side of the water fountain, or Wing walls shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the path of travel. Also, there shall be a minimum of 32 inches clear between the wing walls. c. Note on the plans that drinking fountain shall conform to requirements of Sec. 2-511c and 5-1507. -? 22. PUBLIC TELEPHONE Provide space 30" x 48" for forward or parallel approach to telephone. 2-511.1(d) Note on the plans that public telephone shall conform to requirements of Sec. 2-511.1(d). Z. ELECTRICAL REQUIREMENTS 15, 20 and 30 amp receptacle outlets shall be installed not less than 12" above floor. 3-210-50(e) Center of switches shall be located not less than 36" nor more than 48" above the floor. 3-380-8(c) .Z. PLUMBING REQUIREMENTS a. Where kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc., the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist (i.e., use lever- operated, push-type, etc.). If self- closing valves are used, they shall remain open for at least 10 seconds. 5-1508 AUDITORIUMS, ASSflBLY HALLS, THEATRES, ETC. Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance. 2-611(b) This structure requires wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(b) Each wheelchair space shall be 60" x 30" and level. 2-611(b) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(b) This structure requires seats for semi-ambulant persons. Clear leg space shall be at least 24". 2-611(b) Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible. 2-611(b) 2. STADIUMS, GRANDSTANDS,. BLEACHERS, PAVILIONS, GYMNASIUMS This structure requires wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-611(c) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(c) Ticket booths must be accessible from both sides. 2-611(c) Participation areas such as ball courts, exercise rooms, tracks, and • clubrooms must be accessible. 2-611(c) Spectator and participant sanitary and locker facilities must conform to the requirements of Chapter 2-5. 2-611(c) 27/ DINING, BANQUET AND BAR FACILITIES Access shall be provided at primary entrances. 2-611(d) Wheelchair access shall be provided to all areas where each type of functional activity occurs. 2-611(d) This facility requires wheelchair seating spaces. 2-611(d) At least one wheelchair seating space shall be provided for each dining, banquet and bar area. 2-611(d) Access to wheelchair seating spaces shall be provided by 36" minimum clear width main aisles. 2-611(d) Cafeteria line aisles shall be a minimum of 36" clear width. 2-611(d) Access to food preparation are-as shall comply with provisions for entrance doors and doorways contained, in Section 2-3304. 2-611(d) Restrooms and powder rooms shall conform to the requirements in Section 2-511. 2-611(d) 2. RELIGIOUS FACILITIES Sanctuary areas shall be accessible. 2- 611(e) Provide _ wheelchair seating spaces in the sanctuary. Use Section 2- 611(b). 2-611(e) C. Provide wheelchair access to raised platforms, choir rooms, choir lofts, performing areas and other similar areas. 2-611(e) Assembly areas along with enclosed and unenclosed platforms and stages shall be made accessible. 2-611(e) Sanitary facilities shall conform to the requirements of Chapter 2-5. 2-611(e) 2. ASSISIIVE-LISIENING DEVICES Assembly areas with permanently installed public address systems (other than exclusively for paging or background music), shall provide assistive-listening systems for people with hearing impairments. 2-611(1) Since the capacity of the assembly area 'exceeds 99, this facility requires - personal receivers to be available on request. 2-611(f) C. If the system provided is limited to specific areas or seats, then such areas or seats shall be within a 50-foot viewing distance of the performing area. d. A sign shall be posted in a prominent place indicating the availability of assistive-listening devices. The sign shall include the international symbol of deafness and wording that states "Assistive-listening System Available". GtXJP B OCCUPANCY RXURDIENTS /0. Group B occupancies used for assembly put-poses but having an occupant load of less than 50 shall conform to all the requirements for Group A occupancies covered in Section 2-611. 2-712(d) (1. SALES FACILITIES General sales, display and office areas together with related toilet rooms must be accessible. 2-712(b) Sales employee work stations shall be located on accessible levels. Employee work areas shall be accessible to employees in wheelchairs, and the customer side of sales or checkout stations shall be accessible. 2-712(b) - This facility requires check stands accessible to the physically handicapped, based upon 1 for 8 checkstands or less, 2 for 9 or more. 2- 712(b) Where quick check stands are provided, at least one shall be accessible. 2-712(b) Check stands shall be made accessible by providing a 36" aisle on the customer side of the stand. 2-712(b) Accessible check stands shall be identified by the International Symbol of Accessibility and shall state, "This check stand to be open at all times for handicapped/physically disabled customers". 2-712(b) Z2. FITTING OR DRESSING ROOMS Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the physically handicapped. 2-712(b) Minimum dimension of room shall be 60" x 60". 2-712(b) C. Bottom of the mirror shall be located within 20" of the floor. 2-712(b) d. Height of clothing hooks shall not be greater than 48" from the floor. 2-712(b) 33. a. Accessible sanitation facilities in all / Group H Occupancies shall be provided. as specified in chapter 2-5. 2-913(a) Accessible floors and levels shall comply with the requirements specified in Chapter 2-5. 2-913(a) Employee work areas shall be accessible by means of -a 36-inch minimum aisle width, and a 32-inch minimum clear opening door width. 2-913(a) ADDI'flOS, ALIF2JIIOIS AXD REPAIRS TO EXISTDiG BUfl.DINGS. (2-uoA(b)11) ,. 34. The area of specific addition, alteration and/or 'repair, shall comply with the provisions of Title 24. Additionally: (3) The primary entrance to the building and path of travel to the specific area 'shall be accessible to the handicapped persons. -.. Compliance must be shown, beinnin from the existing parking area an leading to the area of alteration. ()xisting restrooms, water fountains, and public telephones which serve said specific area must be shown to be accessible to and functional for handicapped persons. (. Information regarding handicapped accessibility shall be posted in lobby per Sec. 2-522. 12/29/89 Datei 9II';. JurisdictionCARLSBAD Prepared byt D Bldg. Dept. J+c4- VALUATION AND PLAN CHECK FEE 0 Esgi]. PLAN CHECK NO. _-I BUILDING ADDRESS -115 /3frn&r oo ks u4y APPLICANT/CONTACT ,. //a/ PHONi NO.7&-57 BUILDING OCCUPANCY - DESIGNER PHONE /t If TYPE OF CONSTRUCTION CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA VALUATION I MOLTIPLIER VALUE / TL Cd _______ / 5:, o6 3 -.1 - ____ • 1___ Ct0 • 7 Air ConditioninE Commercial . • . Residential .. . Res. or Comm. Fire SDrinklers •• /'77 Total Value Building Permit Fee $ Plan Check Fee CoMMCNTs 1 O rrh'c.. . • 0 SHEET I OF / 12/87 _ City--of Carlsbad Engineering Department BUILDING PLANCHECK CHECKLIST - DATE :_-30 &EP 92. PLANCHECK NO .Q5 92- 4001 BUILDING ADDRESS 195 PILOM/R OS VJ1-Y PROJECT DESCRIPTION: * ASSESSOR's PARCEL NUMBER: EST. VALUE____________ ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have submitted for review has been Please see the attached report of deficiencies approved: The approval is based on plans, marked with . Make necessary corrections t0 information arid/or specifications provided in your plans-'OC specifications for compliance with submittal; therefore any changes to these items applicable codes and standards. Submit corrected after this date, including field modifications, must plans and/or specifications to this office for review. be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to : comply with instructions in this report can result in - . suspension of permit to build. - • - By:S.SC1EDELL Date: OSEP9L - By: Date • By: - . Date: • H FOR OFFIAL USE ONLY. II BUILDING PLANCHECK CHECKLIST SITE PLAN 1 s 2ndf 3rdv' 0 D 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Property Lines Easements Existing & Proposed Structures E. Easements Existing Street Improvements F. Right-of-Way Width & Adjacent Streets O 0 0 2. Show on site plan: A Drainage Patterns C. Existing Topography B. Existing & Proposed Slopes El o 0 3. Show on a section drawing or include a note stating that there is a minimum of 6" N/1 difference between the finished floor and the finished grade elevation adjacent to the structure. 0 0 0 4. Include note: "Surface water to be directed away from the building foundation at a 2% qA gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)." [Per 1985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the Street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). 121" 0 0 5. Include on title sheet Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION Cs82-0180 IE1ZM1rrED 3-,2--411=-r 2- QFRCE q- I I63P W(1OOSE C884-O'3 PE41rrE A11!T704J'4L 1340 FTL O'FiC.E CER 84— 0605 PERMIUU iO 2-DS P11 OFRCE u 59(3 f4 IOR 4b1)1T70AjAL (4'64 u. P:\docs\chk1st\bp0001.frm Page 1 of 4 REV 6/5/92 / BUILDING PIANCHECK CHECKLIST ,J/f4 DISCRETIONARY APPROVAL COMPLIANCE 1Stv 2nd' 3rd./ 0 0 0 6. Project does not comply with the following Engineering Conditions of approval for Project No. . Conditions were complied with by. Date i'4J4 DEDICATION REQUIREMENTS 0 .0 0 7. Dedication for all street Rights-of-Way adjacent to the building, site and any storm drain or utility easements on. the building site is required for all new buildings and for remodels with a value at or exceeding $______________ -pursuant to Code Section 18.40.030. . Dedication required as follows: Attached please find an application form and submittal checklist for the dedication ' process. Provide the completed application form and the requirements on the checklist at the time..of resubmittal. , . •• . p , • - Dedication completed by Date IMPROVEMENT REQUIREMENTS . . . 0. 0 0 8a. All needed public improvements upon and adjacent to the building site must be . constructed at time of building construction whenever the value of the construction exceeds $ . , . -pursuant to Code Section 18.40.040. Public improvements required as follows:- Please have a registered Civil Engineer prepare appropriate improvement plans and - submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an 'application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal Improvement Plans signed by ____________________________ Date BUILDING PLANCHECK CHECKLIST 1 stJ 2nd 1 3rd,/ 0 0 0 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $_ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City. prior to issuance of a Building Permit. Future public improvements required as follows:_______________________________ \ \ 8c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department Future Improvement Agreement completed by:________________________________ Date:_________________ 0 0 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. - GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. O 0 0 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). O 0 0 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. • •, Grading Inspector sign off by Date 0 • 0 9c. No Grading Permit required. BUILDING PLANCHECK CHECKLIST P:\docs\chk1st\bp0001.frm - Page 3 of 4 • REV 6/5/92 NIA MISCELLANEOUS PERMITS 1 SW 2nd' 3rdv' 0 0 0 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, trees, driveways.. A separate Right-of-Way permit issued by the Engineering Department is required for the, following: Please complete attached Right-of-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the .time of resubmittal. • • El 0 0 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. 0 0 0 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. . Industrial waste permit accepted by: • Date: • -. • _ •• p I U P:\docS\chk1sl\bp0001.frm CALCULATIONS WORKSHEET N EDU CALCULATIONS: EDU's: ADT CALCULATIONS: ADT's: FEES REQUIRED: 4< WITHIN CFD: O YES (NO BRIDGE & THOROUGHFARE FEE, REDUCED TRAFFIC IMPACT FEE) ONO O 1. PARK-IN-LIEU FEE PARK AREA: FEE/UNIT:_________ O 2.TRAFFIC IMPACT FEE ADT's: FEE/ADT: 0 3. BRIDGE AND THOROUGHFARE FEE ADT's: FEE/ADT:___________ - El 4. FACILITIES MANAGEMENT FEE ZONE: . FEE/EDU:_________ O 5. PUBLIC FACILITIES FEE O 6 SEWER FEES PERMIT No. EDU's: FEE/EDU:_________ BENEFIT AREA: FEE: O 7. SEWER LATERAL REQUIRED (2,500 DEPOSIT) ). REMARKS: ThIs a.D \A#S PERMIrTED PblZ iD2i)5 FT2- FF c. I3 FT1 uVA1E-)tjSE. "1OU OFF(CE FT )SE.o TO C ULAT1 -4J SUMS TO 94 I FT zEiouS€ FT USEI TD c2ALC. Pcki&) 11 I2J35 FT2 . 'OU 11ZE £W( 2Z'I4 cT1 itJ ' I( FTL QLtIi'JG .. P:\docs\chklst\bp000l.frm . . REV 6/5/92 r K NO INCRE4SEuJ OiC,E. 2PE ô".J sr LW2 - / PLANNING CHECKLIST Plan Check No. ? /V Address (E ci Og . Planner DAVID RICK - Phone 438-1161 ext. 4328 / (Name) Type of Project and Use Zone PM Facilities Management Zone ______________ Legend Item Complete (J) Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified Environmental Review Required: YES - NO DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES - NO . TYPE APPROVALJRESO. NO. ______ DATE: PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? 'If not, state conditions which require action. 5 Conditions' of 'Approval ' /O cl California Coastal Commission Permit Required: YES NO DATE OF APPROVAL: S San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ODD ODD Zoning: DOD 1. Front: Int. Side: Street Side: Rear: Lot coverage: Required Required Required Required Required Shown Shown Shown Shown Shown Height: Required Shown Parking: Spaces Required '7 Shown 22 Guest Spaces Required Shown C~l /C3 0 Landscape Plan Required: YES NO__ SEe attached submittal requirements for landscape, plans Site Plan: Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grãde adjacent to building, existing topographical lines, existing and proposed slopes and driveway. Provide legal description of property. Provide assessor's parcel number. Setbacks: DOD 2. C , CCI:J1 'Adtional Comments I rni ,.,.I OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE /0)2 PLNCK.FRM City of Carlsbad 92207 Fire Department e Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Repo rt:Wednesday, October 21, 1992 Reviewed by:d Contact Name Dan Dalai Address 9449 Goodwick Court City, State San Diego CA 92123 --Bldg. Dept. No. 92-1004 Planning No. Job Name KWMicrowave Job Address 1985 Palomar Oaks Ste. or Bldg. No. Approved - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with, instructions in this report can result in suspension of permit to construct or install improvements. O Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards: Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFD Job# 92207 File#__________ 2560 Orion Way • Carlsbad, California 92008 (619) 931-2121 92207 Fire Department • Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report:Monday, October 5, 1992 Reviewed by:0. 6QcJL' Contact Name Dan Dalai Address 9449Goodwick Court City, State San Diego CA 92123 Bldg. Dept. No. 92-1004 Planning No. Job Name KWMicrowave Job Address 1985 Palomar Oaks Ste. or Bldg. No. O Approved - The item you have submitted for review has been. approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure óontinued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Z Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Review 1st 3rd Other Agency ID CFDJob# 92207 File#___________ 2560 Orion Way 0 Carlsbad, California 92008. ° (619) 931-2121 RquIrements Category: Building Plan Check HAFo 7 Defiàiency!tern: Pending 01 Project Data Provide complete address and suite designation. Provide building construction information indicating occupancy classification, type of construction, number of stories, aggregate square footage, occupant load, and description of intended uses. Deficiency Item: P e n d I n g 03 Floor Plan Provide a complete floor plan of building or suite. Show exiting from all areas. Indicate use or occupancy of each room including adjacent suite if applicable. Deficiency Item: P e n d I n g 11 Knox Box Knox Box required when access to or within a structure or an area is unduly difficult because of secured openings or where immediate access' is necessary for life saving or fire-fighting purposes. The Fire Dept. will determine the location for the key box and provide an authorized order form. Deficiency Item: P e n d I n g 14 Provide Technical Report The building official may require a technical opinion and report to identify and develop methods of protection from the hazards presented by the hazardous materials. The opinion and report shall be prepared by a qualified person, firm or corporation approved by the building official and shall be provided without charge to the enforcing agency. The opinion and report may include, but is not limited to, the preparation of a hazardous material management plan (HMMP); chemical analysis; recommendations for methods of isolation, separation, containment or protection of hazardous materials or processes. The technical report shall contain a listing of quantities and classification of all hazardous materials which will be stored, dispensed, handled, or used on the premises. Deficiency Item: Pending 15 Automatic Fire Sprinkler System Required An automatic fire sprinkler system shall be installed in occupancies and locations as set forth in UFC 10.306 and the Carlsbad Municipal Code. The Carlsbad Municipal Code requirements for location of fire extinguishing systems are as follows: In buildings two or more stories in height, an autojnatic fire extinguishing system shall be installed in those areas which lie below the lowest elevation of fire department vehicular access. An automatic fire extinguishing system shall be installed in all buildings hereafter constructed in which the aggregate floor area exceeds 10,000 square feet, or in which the existing aggregate floor area is expanded to exceed 10,000 square feet. An automatic fire extinguishing system conforming to either NFPA standards 13 or 13R shall be installed in all one or two story apartment houses and other buildings which contain fewer than 16 attached dwelling units and have an aggregate floor area which exceeds 10,000 square feet. Note: Residential sprinkler systems such as those designed in accordance with NFPA standards 13R and 13D may not be used as the basis for increases to the basic allowable floor area or exemption from any other Uniform Building Code requirement. I Provide information on the design density of the existing sprinkler system. I I Deficiency Item: P e n d I n g 18 Fire Extinguishers Required Provide one 2A1OBC fire extinguisher for each 6000 square feet or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. See item 32 for any additional fire extinguisher requirements. Page 2 10/05/92 Rbquirements Category: Building Plan Check HAFiio7 Deficiency Item: Pending 24 Special Egress Control Devices When approved by the building official, exit doors in Group B, Division 2 Occupancies may be equipped with approved listed special egress-control devices of the time-delay type, provided the building is protected throughout by an approved automatic sprinkler system and an approved automatic smoke-detection system. Such devices shall conform to all of the conditions stated in UBC 3304(e). Deficiency Item: Pe n In g 25 Exit Signs Exit signs shall be installed at required exit doorways and where otherwise necessary to clearly indicate the direction of egress when the exit serves an occupant load of 50 or more. Illumination: Signs shall be internally or externally illuminated by two electric lamps or shall be of an approved self-luminous type. Power Supply: Current supply to one of the lamps for exit signs shall be provided by the premises' wiring system. Power to the other lamp shall be from storage batteries or an on-site generator set. Deficiency Item: Pending 26 Exit Illumination Exits shall be illuminated at any time the building is occupied with light having intensity of not less than 1 footcandle at floor level. The power supply for exit illumination shall normally be provided by the premises'wiring system. In the event of its failure, illumination shall be automatically provided from an emergency system of Group I, Division 1 Occupancies and for all other occupancies where the exiting system serves an occupant load of 100 or more. Deficiency Item: P end In g 28 Corridor Construction I Walls of corridors serving a GroupR, Division 1 or Group I Occupancy having an occupant load of 10 or more and walls of corridors serving other occupancies having an occupant load of 30 or more shall be of not less than one-hour fire-resistive construction and the ceilings shall be not less than that required for a one-hour fire-resistive floor or roof system. Exception for Offices: Corridor walls and ceilings need not be of fire-resistive construction. within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and when the corridor has a listed supervised, low voltage smoke detector system installed. For other exceptions refer to UBC 3305(g) Deficiency Item: P e n d I n g 29 High Piled Combustible Storage Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high piled stock piling is to be done, submit a complete storage plan and description of the commodities to be stored. Show compliance with Article 81 of the Uniform Fire Code. Deficiency Item: P e n d I n g 30 Flammable or Combustible Liquids Storage, dispensing or use of any flammable or combustible liquids shall comply with Article 79 of the Uniform Fire Code. See item 32 for additional requirements. Page 3 10/05/92 Ranuiramants Catnorv: Buildina Plan Check HAFo 7 Deficiency Item: Pending 31 Other Permits Required Permits are required for the blowing: compressed gases, dry cleaning plants, dust producing operations, flammable or combustible liquid tank installation, hazardous materials, hazardous production materials, organic coatings, places of assembly, spraying or dipping, tents, canopies and temporary membrane air-supported structures. See item 32 for specific requirements for other permits. Deficiency Item: Pending 33 Plan Revisions Please submit 2 sets of plans to Esgil and an additional set directly to the Carlsbad Fire Department at 2560 Orion Way, Carlsbad CA 92008. Page 4 10/05/92 COMPUTUD DATuI CU KO._________ DATE BUT NO. OF_I PROJECTs k vJ IlIJd D. I £ I Q I LU to 10) 1LL el DIMENSIONAL DRAWING (cont) r 2'-11 1/2 1 '-O'-3 9/16 [902] [90] OUTSIDE AIR 1'-5 7/8 FILTER/ECONOMIZER ACCESS PANEL ECONOMIZER HOOD [454] 2'-911/16' 0'-3 1/8 CORNER 561 —' •r79] OUTDOOR COIL. CORNER 6 — — O'-S 1/2 II I t1[l40] II (VERTICAL) [320] @IN000R [RURNAIROPENING I i'-o S/8 ------- ••.._ _____ RETURN AIR (HORIZONTAL) II V-11/4" COIL _ II = $ II 37) 5-3 11/16W II DRAIN OPENING I [65] ALT. CONDENSATE I t_ O'-2 9/16 [1617] I IN BASEPAN SUPPLY II I AIR I 2'-4 3/4 I OPENING [730] l lVERTICAL) I I I 1.-b 1/2 I [571.51 I I SUPPLY AIR - - - (HORIZONTAL) '-5 7/16 '2 CORNER C 3'-4 1/4 [138] 13111 /8 CORNER 0 [1022.4] 1 -1 L'-8 3/16 [208] 1-8 7'-3 3/8 I [2219] O'-O 3/8 [10] -. CONTROL BOX & COMPRESSOR ACCESS PANEL INDOOR FAN MOTOR, BLOWER AND ELECTRIC HEAT ACCESS PANEL pp I I A -1 00 FORK TRUCK SLOTS 1 3/8[35] (TYP 8 PLACES) Model 548B090 —6— IN DIMENSIONAL DRAWING (cont) 1'-1 1/4" [3363 I...- ' (101) - 2'-45/16" --' - 1'-05/8" FILTER ACCESS DOOR - [719] [3211 (DISPOSABLE FILTERS) - II RETURN 1i ACCESSORY II AIR 'I 2'-911/16"HOOD FILTER OPENING [856] (HORIZONTAL' / II 1'-11 7/8" 11 SUPPLY A1R" [3521 OPENING i II Ii / I 2'-1 7/8 - l (HORIZONTAL) i II ,, ••J [657] _________________ OUTSIDE AIR 3'-1 1/8" 1,j to'-6 1/8 to'.415I16" * (943) I [156] [125] SUPPLY AIR RETURN AIR (VERTICAL) (VERTICAL) E STD. CONDENSATE DRAIN 2'-6 13/16" [782) Q'7 3/0" -. [187] 1 HO'-3 13116 (971 MOUNT DISCONNECT I IL-S HERE A HF I 2'-O 3/8" [6 19] [1O29)L I I' ___ OUTDOOR COIL 3'-4 1 /2' 0'- 5 3/4" 3/4.r L [95) 4'-11 15/16" (146) O'-2TYP [1522] [51] NOTES: Dimensions in ( ) are in millimeters. Minimum clearance from outdoor coil: 12 inches opposite one side of coil; 36 inches opposite other side of coil (optional as to which side); 60 inches overhead. Minimum recommended clearance for service: 48 inches all 4 sides. 60 inches overhead. On vertical discharge applications, ductwork to be attached to accessory roof curb only. CONNECTION SIZES A 1 3/8' DIA. [35] FIELD POWER SUPPLY HOLE 8 2 1/2DIA [64] POWER SUPPLY KNOCK-OUT C 1 3/401A [44] CHARGING PORT HOLE D . 7/8" DIA. [223 FIELD CONTROL WIRING HOLE E 3/4-14 NPT CONDENSATE DRAIN EE] F 2 DIA [51) POWER SUPPLY KNOCK-OUT ) STD. UNIT WT. ECONOMIZER WT. CORNER WT. (A) CORNER WT. (B) CORNER WT. (C) CORNER WT. (D) 4 LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. 5488090 920 417 27 12 163 74 137 62 235 107 280 1 127 Model 548B090 (cent) -- IP zi INDUSTRIAL WASTE DISCHARGE PERMIT APPLICATION' APPL NO.________10o) IND. CLASS____________l(. BUSINESS NAME K. L. N\1 C_2_e1 4i Ca . TIIi'].];1*1.AQV PHONE NUMBER O2..DO Type of Business (check all that apply) O Agricultural Assembly U Automotive O Chemical Handling Electronics O Food O Government 0 Laboratory C3 Laundry Manufacturing U Medical O Metal Work El Office O Photo Lab O Retail O Service Station - O Warehouse O Other___________________ DESCRIBE WASTE OTHER THAN DOMESTIC (Chemicals, Particulates, etc.)________________________ Al/A - GENERAL DESCRIPTION OF ONSITE WASTEWATER PROCESSING: (chemical & physical characteristics)_ Is business presently in operation at site? 0 YES NO Has Wastewater Discharge Permit been applied for throug,h the Encina Water Authority? 0 YES 0 NO Applicant's Name Su KDEi Th-NTOj Title 4 E)JT Phone 617- 62-OZOO Please Print Agency: 1<. VJ Mi iW Signature: bate Signature of Representative 0 EXEMPT 1Z1. 'NOT EXEMPT Date forwarded to Encina /0-)4-9--) Date_________________ P:\00CS\141SF0RNS\FRWM5 REV. 2/10/92 Hazardous Materials 92- /O1 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE 1PIWIIWIF11BLOIThICT Management Division COUNTY OF SAN DIEGO Business Name Contact Person Telephone K.W. MkRowAuE c.eS'. S -iAS" PA-rL q -. Is s 2-O2OO. Mailing Address City State Zip Plan File# tqs PALW w iq' • Site Address City State Zip Plan File# 54cna p4.-S 48oUE. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION: OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 1. Explosive or Blasting Agents 4. Flammable Solids 7. Pyrophorics 10. Cryogenics 13. Corrosives Compressed Gases 5. Organic Peroxides S. Unstable Reactives 11. Highly Toxic or Toxic Materials 14. Other Health Hazards Flammable or Combustible Liquids 6. Oxidizers 9. Water Reactives 12. Radioactives PART II: COUNTY OF SAN DIEGO HEALTH DEPARTMENT - HAZARDOUS MATERIALS MANAGEMENT DIVISION: CONTINGENCY PLAN REVIEW: / OFFICE USE ONLY If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Management 1. Division, 1255 Imperial Avenue, 3rd Floor, San Diego, CA 92186-5261. Telephone (619) 338-2222 prior to the issuance of a RMPP Exempt building permit. FEES MAY BE REQUIRED Date Initials 0 Yes No RMPP Required CTJ r--J Is your business listed on the reverse side of this form? Will your business dispose of Hazardous Substances or Medical Waste in any amount? Date Initials J . Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, RMPP Completed 500 pounds, 200 cubic feet or carcinogens/reproductive toxins in any quantity? .. Will your business use an existing or install an underground storage tank? Will your business store or handle Acutely Hazardous Materials? - Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions is yes, applicant must contact the Air Pollution Control District, 9150 Chesapeake Drive, San Diego, CA 92123. Telephone (619) 694-3307 prior to the issuance of a building permit. YES NO ] Will the intended occupant install or use any of the equipment listed on the Listing of Air Pollution Control District Permit Categories, on the reverse side of this form? (ANSWER ONLY IF QUESTION 1 I YES.) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 1 2) as listed in the current Directory of School and Community College Districts, published by the San Diego County Office of Education and the current California Private School Directory, compiled in accordance with provisions of Education Code Section 33190? ness \Yl -JJ'i F/t'-) Name of Owner or Authorized Agent: penalty of perjury that to the best of my knowledge and belief the responses made herein are tru and correct. e Signature of Owner or AuzeA gentdcIarnder Date: ¶ ( 2_2- 212- Do not write below this line FIRE DEPARTMENT OCCUPANCY CLASSIFICATION: BY: Date: EXEMPT FROM PERMIT REQUIREMENTS COUNTY-HMMD APCD APPROVED FOR BUILDING PERMIT BUT NOT OCCUPANCY COUNTY-HMMD APCD APPROVED FOR OCCUPANCY COUNTY-HMMD APCD Environmental Health Services County of San Diego DHS:HM-9171 (6/92) Department of Health Services LIST OF BUSINESSES WHICH REQUIRE REVIEW AND APPROVAL FROM COUNTY OF SAN DIEGO HEALTH DEPARTMENT THE HAZARDOUS MATERIALS MANAGEMENT DIVISION AUTOMOTIVE CHEMICAL HANDLING OTHERS AND MISCELLANEOUS Battery Manufacturing/Recycling Boat Yard Car Wash Dealership Maintenance and Paint Machine Shop Painting Radiator Shop Rental Yard Equipment Repair, Preventive Maintenance Repair, Major Overhaul Transportation Services Wrecking and Recycling METAL WORKING Anodizing Chemical Milling/Etching Finish-Coating, Painting Flame Spraying Foundry Machine Shop-Drilling, Lathes, Mills Metal Plating Metal Prepping/Chemical Coating Precious Metal Recovery Sand Blasting, Grinding Steel Fabricator Wrought Iron Manufacturing Agricultural Suppliers/Distributors Chemical Suppliers/Distributors Chemical Manufacturer Coatings/Adhesives Compressed Gas Supplier/Distributor Dry Cleaning- Fiberglass/Resin Applications Gas Station Industrial LaiJndry Laboratories Laboratory Suppliers/Distributors Oil and Fuel Bulk Supply Pesticide Operator/Distributor Photographic Processing Pool Supplies/Maintenance Printing/Blue Printing Road Coatings Swimming Pool (Gas Chlorination Systems Only) Toxic Gas Handler Toxic Gas Mfg. Asphalt Plant Chiropractic Offices Co-Generation Plant Dental Clinic/Offices Dialysis Centers Frozen Food Procealng'Facilitieé ' Government Agencies Hazardous Waste Haulers, Hspitals/Cdnvalscnt Homes Laboratories, Biological Laboratories Medical Clinics/Offices Public Utilities Rock Quarry Veterinary Clinic/Hospitals Wood/Furniture Manufacturer/Refinishing Ship Repair/Construction AEROSPACE Aerospace Industry Aircraft Manufacturing Aircraft Maintenance ELECTRONICS Electronics Components Mfg. tElectrojAsse!&nd Sub Assemby lrinte Circuit Board Mfg. NOTE: THE ABOVE LIST INCLUDES BUSINESSES WHICH TYPICALLY USE, STORE, HANDLE AND DISPOSE OF HAZARDOUS SUBSTANCES. ANY BUSINESS NOT INCLUDED ON THIS LIST WHICH HANDLES, USES OR DISPOSES OF HAZARDOUS SUBSTANCES MAY STILL REQUIRE HAZARDOUS MATERIALS MANAGEMENT DIVISION (HMMD) REVIEW OF BUSINESS PLANS. : FOR MORE INFORMATION CALL (619)338-2222. LISTING OF AIR POLLUTION CONTROL DISTRICT PERMIT CATEGORIES Businesses which include any of the following operations or equipment will require clearance from the Air Pollution Control District. CHEMICAL 47-Organic Gas Sterilizers 32-Acid Chemical Milling 33-Can & Coil Manufacturing 44-Evaporators, Dryers & Stills Processing Organic Materials 24-Dry Chemical Mixing & Detergent Spray Towers 35-Bulk Dry Chemical Storage COATINGS & SURFACE PREPARATION 01-Abrasive Blasting Equipment 27-Coating & Painting 37-Plasma Arc & Ceramic Deposition Spray Booths 38-Paint, Stain & Ink Mfg. METALS 18-Metal Melting Devices 19-Oil Quenching & Salt Baths 32-Hot Dip Galvanizing 39-Precious Metals Refining 25-Gasoline & Alcohol Bulk Plans & Terminals 25-Intermediate Refuelers 26-Gasoline & Alcohol Fuel Dispensing COMBUSTION 34-Piston Internal-Combustion Engines 13-'Boilers & Heaters 0 Million Btu/Hr. or larger) 13-Gas Turbines, and Turbine Test Cells & Stands 14-Incinerators & Crematories 15-Burn Out Ovens 16-Core Ovens ELECTRONICS 29-Solder Levelers 29-Hydrosqueegees 42-Electronic Component Manufacturing FOOD 12-Fish Canneries 12-Smoke Houses 50-Coffee Roasters 35-Bulk Flour & Powdered Sugar Storage ROCK AND MINERAL 04-Hot Asphalt Batch Plants 05-Rock Drills 07-Sand Rock & Aggregate Plants 08-Concrete Batch, CTB, Concrete Mixers, Mixers & Silos 10-Brick Manufacturing SOLVENT USE 28-Vapor & Cold Degreasing 30-Solvent & Extract Driers 31-Dry Cleaning OTHER 03-Asphalt Roofing Kettles and Tankers 46-Reverse Osmosis Membrane Mfg. 51-Aqueous Waste Neutralization 11-Tire Buffers 17-Brake Debonders 23-Bulk Grain & Dry Chemical Transfer & Storage 45-Rubber Mixers 48-Landfill Gas Flare or Recovery Systems 21-Waste Disposal & Reclamation Units 36-Grinding Booths & Rooms 40-Asphalt Pavement Heaters 43-Ceramic Slip Casting 41-Perlite Processing 40-Cooling Towers-Registration Only ORGANIC COMPOUND MARKETING (GASOLINE, ETC.) NOTE: OTHER EQUIPMENT NOT LISTED HERE THAT IS CAPABLE OF EMITTING AIR CONTAMINANTS MAY REQUIRE AN AIR POLLUTION CONTROL DISTRICT PERMIT. IF THERE ARE ANY QUESTIONS, CONTACT THE AIR POLLUTION CONTROL DISTRICT AT (619) 694-3307. Environmental Health Services c-__----. County of San Diego DHS:HM-9171 (6/92) Department of Health Services