HomeMy WebLinkAbout1986 LA COSTA AVE; ; CB090225; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-24-2009 Commercial/Industrial Permit Permit No: CB090225
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
1986 LA COSTA AV CBAD
Tl Sub Type: COMM
Lot#: O Status:
Valuation:
2165901600
$15,000.00 Construction Type: NEW Applied:
Occupancy Group: Reference#: Entered By:
Project Title: LA COSTA RESORT EQUIPMENT YARD Plan Approved:
NEW HEALY CLEAN AIR SEPARATOR FOR FUEL DISPENSING Issued:
Applicant:
JAUREGUI & CULVER INC
959 W MISSION AV 92025
760 7 43-0518
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Inspect Area:
Plan Check#:
Owner:
W2007 LA COSTA RESORT CO LL C
50905 AVENIDA BERMUDAS
LA QUINTA CA 92253
$163.31
$0.00 ·
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee $106.15
$0.00
$0.00
$3.15
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1.00
SDCWAFee
CFD Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
HMP Fee
TOTAL PERMIT FEES
ISSUED
02/10/2009
RMA
03/12/2009
03/12/2009
PC
Total Fees: $273.61 Total Payments To Date: $273.61 Balance Due:
' 'i :,; ..., ( '. ' '··--' ---Cl ,1-:.1, .. ~
___ A.·: 1 , .. ·le:; i:".~.D
Inspector: Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
??
$273.61
$0.00
NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. lf you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Garlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
• ' eity of Carlsbad
1635 Faraday Ave., Carlsbad, CA 92008
, 760-602-2717 / 2718/ 2719
Fax: 760-602-8558
I Cl V cu·11d·1ngwww.carlsbadca.gov
I (/Jfu Permit Application
SUITE#/SPACE # /UNIT#
00
LOT# PHASE# # BEDROOMS # BATHROOMS acc. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
YES □# __ NO □ YES □ NO □ YES □ NO □
ADDRESS H, s.~10.µ Ve
CITY STATE ZIP CITY • STATE
€su-.l'b.,bt:> Ck
PHONE FAX PHONE FAX
71.D -,c.r~ -os s "7t.o • 1 "'3 -o, '1,..
EMAIL EMAIL , ,
..J (... \ lo\ c:.o .. e., Ca,.,~ 0 \ •• C.t> 1M
I S'S, O IJ
STATE ZIP Ck-~~l.5
PHONE FAX
?C.c74~o<s,1 7t,,o 'l-I
EMAIL .
.J C I V\L 0"1 e..
ARCH/DESIGNER NAME & ADDRESS STATE UC.# STATE LIC.#
7D
(Sec. 7011.5 Bu1inM1 and Pr~l~1siom Code: Any City, or _County which r~uire1 a permit (O co~stmt, _alttr/ improve, ~~molish or reP,air. any 1tructureJ prior to ill iuuanu, also requirei the ap_p icant for 1uch p_ermit to file a signed 1t~ttment 1h.it ht ii. ficensed _purmnt ro the prov111on1 of the Contractors License Law {Chapter 9, commendmg with ~eCllon 000 of 01v111on l of the Bustneu .ind Proremons Code} or that he 11 exempt there from, and Ifie bam for the alleged exemption. Any violation of Sfetion 7031.5 by any applicant for a permit 1ubj&t1 Ifie applicant to a civil penalty of not more than fivt hund"d dollm {S500}).
WORKl!RS' COMPl!IIIIA'l'IOl\l
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations:
D I have and wll1 maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
liJ"lhave and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
numberare:lnsuranceCo.STAre: Ce ..... f' IQ,, E'uAJb PolicyNo. l?G 9'1'1A ,_cee ExpirationDate0#-0/-/O
This section need not be complet · e per · for one hundred dollars ($100) or less. 7 / ~ .. 00 3D3 'I-S D Certificate of Exemptio . I certify that in the rt of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: F lure to secure wor mpe satlon coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
rovl or In Section 3706 of the Labor code, interest and attorney's fees.
I hereby affirm that I am exempt from Contractor's License Law for the following reason·
O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not in1ended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
O I am exempt under Section __ Business and Professions Code for this reason
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I {have/ have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone/ type o! work):
_g PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 ol the
Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or luture building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the appllcatlon and state that the above lnfonnatlon Is correct and that the infonnation on the plans is accurate. l agree to comply with all City ordinances and State laws relating to building construction.
l hereby authorize representative of the Ci of Carlsbad to enter upon the above mentioned property !or inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, NTS, JS AND EXPENSES WHICH MAY IN Alfi WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit i quired lor excavation rN oee and demo\tlion or construction of structures rNer 3 stories in height.
EXPIRATION: Every pe ·1 issued by the Building 1cia\ e provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within ~ days from the date of h permit or ii the bui ; g zed by such pennlt is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unfform Building Code),
DATE ,:7--/ i) •O'f
m m City of ca·rlsbad Bldg Inspection Request
For: 08/20/2009
Permit# CB090225 Inspector Assignment: PC
Title: LA COSTA RESORT EQUIPMENT YARD
Description: NEW HEALY CLEAN AIR SEPARATOR FOR FUEL
DISPENSING SYSTEM
Type:TI
Job Address:
Suite:
Location:
Sub Type: COMM
1986 LA COSTA AV
Lot: 0
OWNER W2007 LA COSTA RESORT COLL C
Owner:
Remarks:
---
Phone: 7602160863
Inspector: ~ ~ ~1/
Total Time: Requested By: NA
Entered By: CHRISTINE
CD Description
11 Ftg/Foundation/Piers
19 Final Structural
Act Comments
ft£ '14s ~11kt-41J,, t-~~A,/ -h:e.,;,:1/,~~
_J_ ____________ _
-------·------------------------
-----------------------------------------
Comments/Notices/Holds ,---------
I
N-otice --F-ire-Department "SPECIAL USE PERMIT-for FLAMMABLE/COMBUSTIBLE LIQUIDS ... " Is required prior to Final
Inspection. ----------------------------------
Associated PCRs/CVs Original PC#
Inspection History
Date Description
04/01/2009 89 Final Combo
03/24/2009 11 Ftg/Foundation/Piers
Act lnsp Comments
AP PC FIRE DEPT IS SIGNED OFF
AP PC
Carlsbad 090225
3/2/09
DATE: 3/2/09
JURISDICTION: Carlsbad
PLAN CHECK NO.: 090225
EsGil Corporation
In <Partnersliip wit/i, qovernment for <Bui{ifing Safety
SET: II
PROJECT ADDRESS: 1986 La Costa Ave.
PROJECT NAME: Healy CAS
□~PPLICANT
,JURIS.
□ PLAN REVIEWER
□ FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department
staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list below is transmitted herewith for your information. The plans are being held at
Esgil Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax #:
~ REMARKS Prior to Bldg permit issuance the fire Dept. must approve the location of the
proposed Healy tank for compliance with the Fire Code.
By: Chuck Mendenhall
EsGil Corporation
0 GA O MB O EJ O PC
Enclosures:
2/24/09
EsGil Corporation
In <Partnersfiip witfi <;overnmentfor<Buifaing Safety
DATE: 2/18/09
JURISDICTION: Carlsbad
PLAN CHECK NO.: 090225
PROJECT ADDRESS: 1986 La Costa Ave.
PROJECT NAME: Healy CAS
SET:I
D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[gj The REMARKS check list below is transmitted herewith for your information. The plans are
being held at Esgil Corporation until corrected plans are submitted for recheck. Submit two
sets of responses and revised design to EsGil Corp for recheck
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
[gj The applicant's copy of the check list has been sent to:
Jauregui & Culver, Inc.
959 W. Mission Ave., Escondido, CA 92025
D Esgil Corporation staff did not advise the applicant that the plan check has been completed.
[gj Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person conlacte~/Jo9n Culver Telephone#: (760) 743-0518
Date contactecfY//q/01(by/~) Fax#: (760) 743-0621
~ REMARKS Check List: A. The design calculations for the tank foundation and anchoring of the
tank to the foundation is based on the tank being mounted horizontally on the foundation. The
plans show the tank mounted vertically. Submit revised design consistent with the plans. B.
The structural part of the plans must be signed and stamped by the engineer assuming design
responsibility. C. Prior to Bldg permit issuance the fire Dept. must approve the location of the
proposed Healy tank for compliance with the Fire Code.
By: Chuck Mendenhall
EsGil Corporation
0 GA O MB O EJ O PC
Enclosures:
2/12/09
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad -090225
2/lfJ/09. . '
[DO NOT PAY -THIS IS NOT AN INVOICE}
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 090225
PREPARED BY: Chuck Mendenhall
BUILDING ADDRESS: 1986 La Costa Ave.
DATE: 2/18/09
BUILDING OCCUPANCY: NA TYPE OF CONSTRUCTION: NA
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Healy Tank NA City Est
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Plan Check Fee by Ordinance
Type of Review:
D Repetitive Fee -3 Repeats
Comments:
Complete Review
□ Other
D Hourly
EsGil Fee
Reg. VALUE
Mod.
D Structural Only
f--------ll Hr. @ •
($)
15,000
15,000
$150.751
$97.99I
$84.421
Sheet 1 of 1
macvalue.doc +
.... ,.
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB 09-0225 DATE 2/18/9
ADDRESS 1986 La Costa Av Jt,-Sfo, ((p
RESIDENTIAL ADDITION-
MINOR (<17,000.00)
RETAINING WALL
VILLAGE FAIRE
OTHER healy tank
PLANNER Chris Sexton
POOUSPA
TENANT IMPROVEMENT
COMPLETE OFFICE BUILDING
DATE 2/18/9
ENGINEEty_.-,==-----DATE i11tqlo1
Hc\ADMIN\ COUNTF.R/PLINNING /ENGINEEfilNG APPROV Al.I
.
. ■ . Carlsbad Fire Department ~~-,, ar' ""ING oerr-r ~=-c.1-J..L" r 111
~OPY
Plan Review Requirements Category: TI , COMM
Date of Report: 03-09-2009 Reviewed by: ----4<+~_/!, __ ~~ ........ "f~
Name:
Address:
Permit #: CB090225
JAUREGUI & CUL VER INC
959 W MISSION AV
ESCONDIDO CA 92025
Job Name:
Job Address:
LA COSTA RESORT EQUIPMENT YARD
1986 LA COSTA AV CBAD
The item you have submitted for review is i
ad~--ew
care a comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval.
Conditions:
Cond: CON0003339
[MET]
•• City of Carlsbad Fire Department E:ROVE;:,
Subject to field inspection and required tests, notations hereon, conditions in correspondence and
conformance with applicable regulations. The stamping of these plans shall not be held to permit or
approve the violation of any law.
Article 1 of the Carlsbad (California) Fire Code requires that the owner/operator obtain a "Special
Use Permit" from the CFD. Under Chapter 22 of the 2007 ed. of the CFC, you shall obtain a
'Flammable and Combustible Liquids Dispensing, Use, Storage and Tanks' permit. You may obtain this
permit by contacting the Carlsbad Fire Department at 760-602-4665.
Additionally, Fire Code requires that inspection of of all underground piping prior to burial if
appropriate.
Entry: 03/09/2009 By: GR Action: AP SPECIAL USE PERMIT REQUIRED
CONTENTS:
COVERSHEET
CALCULATIONS
FRANKLIN FUELING SYSTEMS
CLEAN AIR SEPARATOR
CONCRETE FOUNDATION
1. Cl calculation sheet
2. C2 calculation sheet
3. Franklin Fueling Dwg. 9900-9945V Mounting Slab Details
4. CA State Fire Marshal CODE INTERPRETATION 06-124
By
JamesH.Ray
Ovit Engineer
Santa Rosa, CA
707-480-8115
l ,
' ~ ~i
. sst J ~ ~----ll'!I--+ . -
I
I
I
-.lil.--"---l-..:::::..-:::::.,,,.J._
oO
32."
@. 32 f + Sf-I-Bf -/"\
I • • 4 1'., \:; "-.J-'\
!jo◊CAS
I
3,73'
i
No,E: 1 At:l<!\v~ Bo1.-n \tJS'"t-'\L \.1), Tfll~/V/1)()./\1..
LDA,)t w,\l vM'< Wl"'7<~ w11vt 'bVt<:<:r1c:.,,J
t-'¼i \f"\IAM l?>aL-c ·L:c.i/\'.i) 15 WIN'\) ltJ 1)l~£l7{u.-.J A
AN<>t<,f\... Bolt.s t<> ~t S'tQ11-,).qn St-co l H.lf, Kw\~
BoLI "T'Z.. S "w,+t; 4•· E.\itti1vE' MIi-\ f?l-,,,he-J w,,'f"lt,
"'tt .. (\q LOI-\ p ei,,, E. $ R -I<\ ( 7 see~ lt~..-~tt. b<-lvw
GASE 501} l3<2ar1 nj . ·
Mo T •· 35'l (~ l-+ g1e) : '2. I/.> 7. ~"ti
f'\[?<Y\S· Boo (2.L./) =-t 1l'2.ao''1't} '57,t,<Jo"11
r-'\p_84'JC:.; I (ooo-(;;..t;) : -38, 4 C>6 I•" f
w :. -Z. ~o o 35,770
3,'73 f\ 80D
2. P: l\2.°i1t
X= M.2 74 -. IY , 1( '2.406
f 5 :z ~ -?. 0, 88 d'<,µ,1.4
l
10"¼ I_ (): 1fZ 9-+ \00 ~ S'Z. ~ fSf
.-_MAX S'OIL 6 EA1(\ \JG; 529 PSF {,.1006 c,K
Alte-..Mt~ tl,Y\t~(.l"~olt: \,\,(ti ~t<>.,.,.\u1 (Terl kw,KBC.L"'C 3 I
5/~/d,~Wlt..hr l\ .. E.{'.fett1v-e.ew.kJw-e.~. , ,
lhs°1all p< .. ES~-,~85 1scu.e.d 'H-o~
... r r:
fMN K' L lA.1 ft-\.~ L-\.,.JC
SYSTEM CAS-V·
t.O!'>-t"'O ~L-C::.U.LAitoi-'S JAl"'\E'S .H. RAY,C,oil E..11~1Y\eel"' ,....,,
W\1'1,/1) c.'f SE-ISM IC SAr->-rA r<..OSA, CA '-'-
\'2.-~l-07
Col)E A SCE.. 1-6 S IBL 20o~ c Be z.001 Ji\<R•tfei-..11,-e oJJ~ I-S-8 "'
\-C\-08
S E. \ SM \ C , 1 .J.-
, '5. 'TA,v~.s~VeSS<€LS w,+Y\ ho l1qu.\cl (O")l~nL Seet<x.tnot-e O},
(AS-t6.ie f1H Vien-she.I (c,d~ I11tr,icrcttoh tt o(.,~\Z'-1 atttlc~ttl
2.6_1 s IT~ (1.Asn.f1ctd1oh ~ D
I I 1 "-l $E.tS~ \ c. G (<6(..lN D ~\U 1"/{j,0 5
\ \, ll I fl ('It,(~ E '2.. 1.-\ 5 s ... '2. ftt = I, 0 '1 A l?L{ \ \, \.1-1
I '2.'2.-1 ~~121 fv~\.'$ 11 \\.'--1-'l
\\ .. l!,'3' 5,vts ::-f~ Ss :-(f.0 )(2.) = 2.◊ ( l\.ll-1)
SM, ~ f ,/~ ~ ( b '5 )( I, 5) :: \. 0 ( \ Ii '-l • Z)
I I . .LI,, L) 5 DS:: ½ S MS ~tt)(26):: \ij j .. tr f\
s'D, -: { s,M, ~ (~) ( 1J~): 1,00 -0
(--~.r1 L ( I I• \q-\)
(i.A.f$L6 I ,.~-2.)
!--l\-1 \ I • S -I 1 :. l ~ i A ei LE :i-1
. \'l . 7,?.
l~,B
\'z...f), I
w --'ooot6 .
[Q l \J A L<::...vf rc.,rc C ( f (2..o ( C.<-l)(.{ {( f
\J= C.s W
\'l.8.1.\ Cs= j~1 -~ : 6, lf Y ~ 3/ \ I ·w = 300 Wl lcf{, ~r v~ss f-\.
SEISMI( \ V: (q1~~)(goo) :--'35 '2. ti\
I W\A-11)] t = ~~ G c~ A,. (~.S.15) 'N1rv1> \ f-:. (11i11)(D1~S)(0SL\'3)('2?J'):. 2 3 \ 11.\ q1. : o.oq z.s, Kik'1.1 kd v 2 r ( 6• 5. 10)
. k' • J.o1 (Tal,le ,.~) ,.
i:+.,_ (~~}<.Kz.1(3)\ (i,1,o+-0+"): 1 (f,,.G,-'() lvo1E 51:.ISM\C... >WtJJ1).
kc\, 0.'\ 5 (,4 ~le l ·Lf)
V'-., 1oo'l., 10,000
"'I I , o. & T ill -;flt~\. E-$ H {~-I
: :. i't , o.oo2.Sl(t.o'3)(l)(o.'\S)(10,oo,,)(o.8 1)= 2\.'7'l
I c, , o.85 (,.s.ts.r)
D. _ --9 Z )I 3~ ; '2... :>
I 'f \1./L\
C; (1alol~ b~2./}
: 'Dfyc3~1: 14,60
..h..: ~: 2'!:'/ I) ~(p •-;)l.,
\ o. Ii
i..s, 6.'/3 0.5~3 _
'l cJ .l
Cf, O.SLl'3
CM '8:SEl.a,OOIIC
.i. r '> , __ .,,
---•CU'S 9T01>DS
~.;.::,:-.:'i~ na BASE ~LAN
(liUTI tCll>O: ACCIPtMCI Cll'llli\ NR Clll,-ffll ,.,,.,.,_ £ SCMf • .l) • t'-d" --
)
MW 110: 9900-9945
l/h
I l . ,; . • • l'ru 11121[; Awot MX:-£5 ACCrPTNa atlltRfA ,s H9I REPWD. ,tr X I" Ml.Tl QI( 1101.T J e 4• £laElJWDIT Ilk
SEC~ '{rGA~ SLAB .... • '. r.:;,
aml!IA SOI. 8EARINC 1000 pof
BASIC "MNO SPC£D 100mpl,
SOSMIC S.•29 S,,.19
-. COl«:RElE c,:,wp $11!ille'TH, fl -2SOO pll 11N. REW. 'l'IQD SlllEHClll. ', • -40000 psi
ft [A0f W.Y 1W' •• ~ 0.C.
CAN IIE USED (P£1! E51t-1JB5 IIEl'OIIT. IS'SU£D Oll/01/04).
TYPICAL HOLD DOWN CUP ~--
11-aa---• ·IZ••----~--DESCRIPQ --------·-................ _ .. ...................... .......,.,,.
-:",.""-• 001111fS01£111Aa .a t.02 :-i:--::-.. =:, ~ IDI 1IUMm .m t.006 -------
::C.T'.-~ ~---ftCl'ID) -t 1/r ~ .. ,::.-=.-Sl'mM. IIISt
---:,:,vv-vv,...., ··-• --• Cl' 1
Date Issued
Topic
Code Sectlon(s)
Requested by
California State Fire Marshal
CODE INTERPRETATION
July 27, 2007 j Interpretation I oe-124
Healy Clean Air Separator (CAS) Tank as a "Vapor
Processina Unir
CFC 5202.13.3.9
Don Foster
Gettler-Ryan Inc.
1364 N. McDowell Blvd, Suite 82
Petaluma, CA 95954
The Calffomla State Fire Marshal has accepted the UL certification of the
Healy Clean Air Separator (CAS) Tank as a "Vapor Processing Unit". 2001
CFC Section 5202.13.3.9 Indicates that the vent tennlna,lon from vapor
processing units shall be not less than B feet above the processing unit
Itself.
All of the Healy lnstallatlon materials and the Calffomla Air Resources
Board Executive Order VR-202-A exhibits Indicate that the underground
storage tank pressure vacuum vent valve termination need only be located
12 feet above grade. No reference Is made to the 8 foot separation
requirement.
We have two Questions for your consideration and Interpretation:
1. Does the UST pressure vacuum vent valve need to be located B feet
above the CAS Tank as Indicated on the attached Deta/11?
No. The design of the CAS is such that all vapors from the UST are completely
trapped within the "bladder" contained In the CAS. The vent coming from the
CAS is to vent the interstitial space between the bladder and the outside wall of
the CAS. (See footnote below)
2. Is the Healy CAS Air Breather Assembly considered an underground
tank vent In the context of NEC Article 514, Group D, DMslon 1 and 2
Hazardous Locations? ·
As described in the above, the UST Is "vented" to the bladder contained within
the CAS and by design, no vapors are emitted to atmosphere. (See footnote
below)
Foot oot,: The Intent of this footnote Is for reference only and to provide clarification. It Is
not the Intent of the State Flra Marshal to endorse any one specific product, device or
methodology.
DelCrlptlon of Opamlon of the Haaly Clean Air Seperetor TM:
The Healy Systems, Inc., Model 9961 Healy Clean /IIJr Separator"' Is e stand-alone, completely
mechanical device that assists In controlling the gasoline vapor emissions from a gasoline
dispensing facility. It consists of a 400-gaUon stOl'llge vessel with Integral bladder and associated
valving. It Is connected to the ullage space of the GDF storage tanks via the venting systam of the
under ground storage tanks. During normal operation of the GDF, with today's concentration of
ORVR vehicles approximating 20%, the storage tank ullage space wtU usually operate In the "O-
to negative (up to s• WC PN crecklng pressure) pressure range. During" dosed" periods of the
GDF, the ullage pressure wlll usuaHy begin to Increase due to vapor growth Inherent In th11
process of introducing air Into the usrs. If the pressure goes slightly abo\'.e atmospheric the
vapor from the usrs Will flow Into the Internal bladder. Conversely, when ORVR refueling begins
and the UST pressure falls below atmospheric, the vapor Internal to the bladder wHI be drawn
back Into the UST unUI the bladder Is fuHy collapsed waiting for the next cycle.
The Clean Air Separator"' In over two and one half years (Installed late September of 2002) of
being In operation at our C.A.R.B. test site In Sacramento has been evaluated repeatedly to see If
there Is any liquid condensaUon In either the bladder or the space between Iha Inner wau ot t,e
vessel and outer wall of the bladder. To date there has been no liquid found In either area.