Loading...
HomeMy WebLinkAbout1986 LA COSTA AVE; ; CB090225; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-24-2009 Commercial/Industrial Permit Permit No: CB090225 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: 1986 LA COSTA AV CBAD Tl Sub Type: COMM Lot#: O Status: Valuation: 2165901600 $15,000.00 Construction Type: NEW Applied: Occupancy Group: Reference#: Entered By: Project Title: LA COSTA RESORT EQUIPMENT YARD Plan Approved: NEW HEALY CLEAN AIR SEPARATOR FOR FUEL DISPENSING Issued: Applicant: JAUREGUI & CULVER INC 959 W MISSION AV 92025 760 7 43-0518 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Inspect Area: Plan Check#: Owner: W2007 LA COSTA RESORT CO LL C 50905 AVENIDA BERMUDAS LA QUINTA CA 92253 $163.31 $0.00 · Meter Size Add'I Reel. Water Con. Fee Meter Fee $106.15 $0.00 $0.00 $3.15 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES ISSUED 02/10/2009 RMA 03/12/2009 03/12/2009 PC Total Fees: $273.61 Total Payments To Date: $273.61 Balance Due: ' 'i :,; ..., ( '. ' '··--' ---Cl ,1-:.1, .. ~ ___ A.·: 1 , .. ·le:; i:".~.D Inspector: Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 ?? $273.61 $0.00 NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. lf you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Garlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any • ' eity of Carlsbad 1635 Faraday Ave., Carlsbad, CA 92008 , 760-602-2717 / 2718/ 2719 Fax: 760-602-8558 I Cl V cu·11d·1ngwww.carlsbadca.gov I (/Jfu Permit Application SUITE#/SPACE # /UNIT# 00 LOT# PHASE# # BEDROOMS # BATHROOMS acc. GROUP DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YES □# __ NO □ YES □ NO □ YES □ NO □ ADDRESS H, s.~10.µ Ve CITY STATE ZIP CITY • STATE €su-.l'b.,bt:> Ck PHONE FAX PHONE FAX 71.D -,c.r~ -os s "7t.o • 1 "'3 -o, '1,.. EMAIL EMAIL , , ..J (... \ lo\ c:.o .. e., Ca,.,~ 0 \ •• C.t> 1M I S'S, O IJ STATE ZIP Ck-~~l.5 PHONE FAX ?C.c74~o<s,1 7t,,o 'l-I EMAIL . .J C I V\L 0"1 e.. ARCH/DESIGNER NAME & ADDRESS STATE UC.# STATE LIC.# 7D (Sec. 7011.5 Bu1inM1 and Pr~l~1siom Code: Any City, or _County which r~uire1 a permit (O co~stmt, _alttr/ improve, ~~molish or reP,air. any 1tructureJ prior to ill iuuanu, also requirei the ap_p icant for 1uch p_ermit to file a signed 1t~ttment 1h.it ht ii. ficensed _purmnt ro the prov111on1 of the Contractors License Law {Chapter 9, commendmg with ~eCllon 000 of 01v111on l of the Bustneu .ind Proremons Code} or that he 11 exempt there from, and Ifie bam for the alleged exemption. Any violation of Sfetion 7031.5 by any applicant for a permit 1ubj&t1 Ifie applicant to a civil penalty of not more than fivt hund"d dollm {S500}). WORKl!RS' COMPl!IIIIA'l'IOl\l Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: D I have and wll1 maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. liJ"lhave and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy numberare:lnsuranceCo.STAre: Ce ..... f' IQ,, E'uAJb PolicyNo. l?G 9'1'1A ,_cee ExpirationDate0#-0/-/O This section need not be complet · e per · for one hundred dollars ($100) or less. 7 / ~ .. 00 3D3 'I-S D Certificate of Exemptio . I certify that in the rt of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: F lure to secure wor mpe satlon coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in rovl or In Section 3706 of the Labor code, interest and attorney's fees. I hereby affirm that I am exempt from Contractor's License Law for the following reason· O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not in1ended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section __ Business and Professions Code for this reason 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I {have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone I contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone/ type o! work): _g PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 ol the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or luture building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the appllcatlon and state that the above lnfonnatlon Is correct and that the infonnation on the plans is accurate. l agree to comply with all City ordinances and State laws relating to building construction. l hereby authorize representative of the Ci of Carlsbad to enter upon the above mentioned property !or inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, NTS, JS AND EXPENSES WHICH MAY IN Alfi WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit i quired lor excavation rN oee and demo\tlion or construction of structures rNer 3 stories in height. EXPIRATION: Every pe ·1 issued by the Building 1cia\ e provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within ~ days from the date of h permit or ii the bui ; g zed by such pennlt is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Unfform Building Code), DATE ,:7--/ i) •O'f m m City of ca·rlsbad Bldg Inspection Request For: 08/20/2009 Permit# CB090225 Inspector Assignment: PC Title: LA COSTA RESORT EQUIPMENT YARD Description: NEW HEALY CLEAN AIR SEPARATOR FOR FUEL DISPENSING SYSTEM Type:TI Job Address: Suite: Location: Sub Type: COMM 1986 LA COSTA AV Lot: 0 OWNER W2007 LA COSTA RESORT COLL C Owner: Remarks: --- Phone: 7602160863 Inspector: ~ ~ ~1/ Total Time: Requested By: NA Entered By: CHRISTINE CD Description 11 Ftg/Foundation/Piers 19 Final Structural Act Comments ft£ '14s ~11kt-41J,, t-~~A,/ -h:e.,;,:1/,~~ _J_ ____________ _ -------·------------------------ ----------------------------------------- Comments/Notices/Holds ,--------- I N-otice --F-ire-Department "SPECIAL USE PERMIT-for FLAMMABLE/COMBUSTIBLE LIQUIDS ... " Is required prior to Final Inspection. ---------------------------------- Associated PCRs/CVs Original PC# Inspection History Date Description 04/01/2009 89 Final Combo 03/24/2009 11 Ftg/Foundation/Piers Act lnsp Comments AP PC FIRE DEPT IS SIGNED OFF AP PC Carlsbad 090225 3/2/09 DATE: 3/2/09 JURISDICTION: Carlsbad PLAN CHECK NO.: 090225 EsGil Corporation In <Partnersliip wit/i, qovernment for <Bui{ifing Safety SET: II PROJECT ADDRESS: 1986 La Costa Ave. PROJECT NAME: Healy CAS □~PPLICANT ,JURIS. □ PLAN REVIEWER □ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list below is transmitted herewith for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: ~ Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: ~ REMARKS Prior to Bldg permit issuance the fire Dept. must approve the location of the proposed Healy tank for compliance with the Fire Code. By: Chuck Mendenhall EsGil Corporation 0 GA O MB O EJ O PC Enclosures: 2/24/09 EsGil Corporation In <Partnersfiip witfi <;overnmentfor<Buifaing Safety DATE: 2/18/09 JURISDICTION: Carlsbad PLAN CHECK NO.: 090225 PROJECT ADDRESS: 1986 La Costa Ave. PROJECT NAME: Healy CAS SET:I D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [gj The REMARKS check list below is transmitted herewith for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. Submit two sets of responses and revised design to EsGil Corp for recheck D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. [gj The applicant's copy of the check list has been sent to: Jauregui & Culver, Inc. 959 W. Mission Ave., Escondido, CA 92025 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [gj Esgil Corporation staff did advise the applicant that the plan check has been completed. Person conlacte~/Jo9n Culver Telephone#: (760) 743-0518 Date contactecfY//q/01(by/~) Fax#: (760) 743-0621 ~ REMARKS Check List: A. The design calculations for the tank foundation and anchoring of the tank to the foundation is based on the tank being mounted horizontally on the foundation. The plans show the tank mounted vertically. Submit revised design consistent with the plans. B. The structural part of the plans must be signed and stamped by the engineer assuming design responsibility. C. Prior to Bldg permit issuance the fire Dept. must approve the location of the proposed Healy tank for compliance with the Fire Code. By: Chuck Mendenhall EsGil Corporation 0 GA O MB O EJ O PC Enclosures: 2/12/09 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576 Carlsbad -090225 2/lfJ/09. . ' [DO NOT PAY -THIS IS NOT AN INVOICE} VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 090225 PREPARED BY: Chuck Mendenhall BUILDING ADDRESS: 1986 La Costa Ave. DATE: 2/18/09 BUILDING OCCUPANCY: NA TYPE OF CONSTRUCTION: NA BUILDING AREA Valuation PORTION ( Sq. Ft.) Multiplier Healy Tank NA City Est Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Plan Check Fee by Ordinance Type of Review: D Repetitive Fee -3 Repeats Comments: Complete Review □ Other D Hourly EsGil Fee Reg. VALUE Mod. D Structural Only f--------ll Hr. @ • ($) 15,000 15,000 $150.751 $97.99I $84.421 Sheet 1 of 1 macvalue.doc + .... ,. PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 09-0225 DATE 2/18/9 ADDRESS 1986 La Costa Av Jt,-Sfo, ((p RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE OTHER healy tank PLANNER Chris Sexton POOUSPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING DATE 2/18/9 ENGINEEty_.-,==-----DATE i11tqlo1 Hc\ADMIN\ COUNTF.R/PLINNING /ENGINEEfilNG APPROV Al.I . . ■ . Carlsbad Fire Department ~~-,, ar' ""ING oerr-r ~=-c.1-J..L" r 111 ~OPY Plan Review Requirements Category: TI , COMM Date of Report: 03-09-2009 Reviewed by: ----4<+~_/!, __ ~~ ........ "f~ Name: Address: Permit #: CB090225 JAUREGUI & CUL VER INC 959 W MISSION AV ESCONDIDO CA 92025 Job Name: Job Address: LA COSTA RESORT EQUIPMENT YARD 1986 LA COSTA AV CBAD The item you have submitted for review is i ad~--ew care a comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0003339 [MET] •• City of Carlsbad Fire Department E:ROVE;:, Subject to field inspection and required tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or approve the violation of any law. Article 1 of the Carlsbad (California) Fire Code requires that the owner/operator obtain a "Special Use Permit" from the CFD. Under Chapter 22 of the 2007 ed. of the CFC, you shall obtain a 'Flammable and Combustible Liquids Dispensing, Use, Storage and Tanks' permit. You may obtain this permit by contacting the Carlsbad Fire Department at 760-602-4665. Additionally, Fire Code requires that inspection of of all underground piping prior to burial if appropriate. Entry: 03/09/2009 By: GR Action: AP SPECIAL USE PERMIT REQUIRED CONTENTS: COVERSHEET CALCULATIONS FRANKLIN FUELING SYSTEMS CLEAN AIR SEPARATOR CONCRETE FOUNDATION 1. Cl calculation sheet 2. C2 calculation sheet 3. Franklin Fueling Dwg. 9900-9945V Mounting Slab Details 4. CA State Fire Marshal CODE INTERPRETATION 06-124 By JamesH.Ray Ovit Engineer Santa Rosa, CA 707-480-8115 l , ' ~ ~i . sst J ~ ~----ll'!I--+ . - I I I -.lil.--"---l-..:::::..-:::::.,,,.J._ oO 32." @. 32 f + Sf-I-Bf -/"\ I • • 4 1'., \:; "-.J-'\ !jo◊CAS I 3,73' i No,E: 1 At:l<!\v~ Bo1.-n \tJS'"t-'\L \.1), Tfll~/V/1)()./\1.. LDA,)t w,\l vM'< Wl"'7<~ w11vt 'bVt<:<:r1c:.,,J t-'¼i \f"\IAM l?>aL-c ·L:c.i/\'.i) 15 WIN'\) ltJ 1)l~£l7{u.-.J A AN<>t<,f\... Bolt.s t<> ~t S'tQ11-,).qn St-co l H.lf, Kw\~ BoLI "T'Z.. S "w,+t; 4•· E.\itti1vE' MIi-\ f?l-,,,he-J w,,'f"lt, "'tt .. (\q LOI-\ p ei,,, E. $ R -I<\ ( 7 see~ lt~..-~tt. b<-lvw GASE 501} l3<2ar1 nj . · Mo T •· 35'l (~ l-+ g1e) : '2. I/.> 7. ~"ti f'\[?<Y\S· Boo (2.L./) =-t 1l'2.ao''1't} '57,t,<Jo"11 r-'\p_84'JC:.; I (ooo-(;;..t;) : -38, 4 C>6 I•" f w :. -Z. ~o o 35,770 3,'73 f\ 80D 2. P: l\2.°i1t X= M.2 74 -. IY , 1( '2.406 f 5 :z ~ -?. 0, 88 d'<,µ,1.4 l 10"¼ I_ (): 1fZ 9-+ \00 ~ S'Z. ~ fSf .-_MAX S'OIL 6 EA1(\ \JG; 529 PSF {,.1006 c,K Alte-..Mt~ tl,Y\t~(.l"~olt: \,\,(ti ~t<>.,.,.\u1 (Terl kw,KBC.L"'C 3 I 5/~/d,~Wlt..hr l\ .. E.{'.fett1v-e.ew.kJw-e.~. , , lhs°1all p< .. ES~-,~85 1scu.e.d 'H-o~ ... r r: fMN K' L lA.1 ft-\.~ L-\.,.JC SYSTEM CAS-V· t.O!'>-t"'O ~L-C::.U.LAitoi-'S JAl"'\E'S .H. RAY,C,oil E..11~1Y\eel"' ,....,, W\1'1,/1) c.'f SE-ISM IC SAr->-rA r<..OSA, CA '-'- \'2.-~l-07 Col)E A SCE.. 1-6 S IBL 20o~ c Be z.001 Ji\<R•tfei-..11,-e oJJ~ I-S-8 "' \-C\-08 S E. \ SM \ C , 1 .J.- , '5. 'TA,v~.s~VeSS<€LS w,+Y\ ho l1qu.\cl (O")l~nL Seet<x.tnot-e O}, (AS-t6.ie f1H Vien-she.I (c,d~ I11tr,icrcttoh tt o(.,~\Z'-1 atttlc~ttl 2.6_1 s IT~ (1.Asn.f1ctd1oh ~ D I I 1 "-l $E.tS~ \ c. G (<6(..lN D ~\U 1"/{j,0 5 \ \, ll I fl ('It,(~ E '2.. 1.-\ 5 s ... '2. ftt = I, 0 '1 A l?L{ \ \, \.1-1 I '2.'2.-1 ~~121 fv~\.'$ 11 \\.'--1-'l \\ .. l!,'3' 5,vts ::-f~ Ss :-(f.0 )(2.) = 2.◊ ( l\.ll-1) SM, ~ f ,/~ ~ ( b '5 )( I, 5) :: \. 0 ( \ Ii '-l • Z) I I . .LI,, L) 5 DS:: ½ S MS ~tt)(26):: \ij j .. tr f\ s'D, -: { s,M, ~ (~) ( 1J~): 1,00 -0 (--~.r1 L ( I I• \q-\) (i.A.f$L6 I ,.~-2.) !--l\-1 \ I • S -I 1 :. l ~ i A ei LE :i-1 . \'l . 7,?. l~,B \'z...f), I w --'ooot6 . [Q l \J A L<::...vf rc.,rc C ( f (2..o ( C.<-l)(.{ {( f \J= C.s W \'l.8.1.\ Cs= j~1 -~ : 6, lf Y ~ 3/ \ I ·w = 300 Wl lcf{, ~r v~ss f-\. SEISMI( \ V: (q1~~)(goo) :--'35 '2. ti\ I W\A-11)] t = ~~ G c~ A,. (~.S.15) 'N1rv1> \ f-:. (11i11)(D1~S)(0SL\'3)('2?J'):. 2 3 \ 11.\ q1. : o.oq z.s, Kik'1.1 kd v 2 r ( 6• 5. 10) . k' • J.o1 (Tal,le ,.~) ,. i:+.,_ (~~}<.Kz.1(3)\ (i,1,o+-0+"): 1 (f,,.G,-'() lvo1E 51:.ISM\C... >WtJJ1). kc\, 0.'\ 5 (,4 ~le l ·Lf) V'-., 1oo'l., 10,000 "'I I , o. & T ill -;flt~\. E-$ H {~-I : :. i't , o.oo2.Sl(t.o'3)(l)(o.'\S)(10,oo,,)(o.8 1)= 2\.'7'l I c, , o.85 (,.s.ts.r) D. _ --9 Z )I 3~ ; '2... :> I 'f \1./L\ C; (1alol~ b~2./} : 'Dfyc3~1: 14,60 ..h..: ~: 2'!:'/ I) ~(p •-;)l., \ o. Ii i..s, 6.'/3 0.5~3 _ 'l cJ .l Cf, O.SLl'3 CM '8:SEl.a,OOIIC .i. r '> , __ .,, ---•CU'S 9T01>DS ~.;.::,:-.:'i~ na BASE ~LAN (liUTI tCll>O: ACCIPtMCI Cll'llli\ NR Clll,-ffll ,.,,.,.,_ £ SCMf • .l) • t'-d" -- ) MW 110: 9900-9945 l/h I l . ,; . • • l'ru 11121[; Awot MX:-£5 ACCrPTNa atlltRfA ,s H9I REPWD. ,tr X I" Ml.Tl QI( 1101.T J e 4• £laElJWDIT Ilk SEC~ '{rGA~ SLAB .... • '. r.:;, aml!IA SOI. 8EARINC 1000 pof BASIC "MNO SPC£D 100mpl, SOSMIC S.•29 S,,.19 -. COl«:RElE c,:,wp $11!ille'TH, fl -2SOO pll 11N. REW. 'l'IQD SlllEHClll. ', • -40000 psi ft [A0f W.Y 1W' •• ~ 0.C. CAN IIE USED (P£1! E51t-1JB5 IIEl'OIIT. IS'SU£D Oll/01/04). TYPICAL HOLD DOWN CUP ~-- 11-aa---• ·IZ••----~--DESCRIPQ --------·-................ _ .. ...................... .......,.,,. -:",.""-• 001111fS01£111Aa .a t.02 :-i:--::-.. =:, ~ IDI 1IUMm .m t.006 ------- ::C.T'.-~ ~---ftCl'ID) -t 1/r ~ .. ,::.-=.-Sl'mM. IIISt ---:,:,vv-vv,...., ··-• --• Cl' 1 Date Issued Topic Code Sectlon(s) Requested by California State Fire Marshal CODE INTERPRETATION July 27, 2007 j Interpretation I oe-124 Healy Clean Air Separator (CAS) Tank as a "Vapor Processina Unir CFC 5202.13.3.9 Don Foster Gettler-Ryan Inc. 1364 N. McDowell Blvd, Suite 82 Petaluma, CA 95954 The Calffomla State Fire Marshal has accepted the UL certification of the Healy Clean Air Separator (CAS) Tank as a "Vapor Processing Unit". 2001 CFC Section 5202.13.3.9 Indicates that the vent tennlna,lon from vapor processing units shall be not less than B feet above the processing unit Itself. All of the Healy lnstallatlon materials and the Calffomla Air Resources Board Executive Order VR-202-A exhibits Indicate that the underground storage tank pressure vacuum vent valve termination need only be located 12 feet above grade. No reference Is made to the 8 foot separation requirement. We have two Questions for your consideration and Interpretation: 1. Does the UST pressure vacuum vent valve need to be located B feet above the CAS Tank as Indicated on the attached Deta/11? No. The design of the CAS is such that all vapors from the UST are completely trapped within the "bladder" contained In the CAS. The vent coming from the CAS is to vent the interstitial space between the bladder and the outside wall of the CAS. (See footnote below) 2. Is the Healy CAS Air Breather Assembly considered an underground tank vent In the context of NEC Article 514, Group D, DMslon 1 and 2 Hazardous Locations? · As described in the above, the UST Is "vented" to the bladder contained within the CAS and by design, no vapors are emitted to atmosphere. (See footnote below) Foot oot,: The Intent of this footnote Is for reference only and to provide clarification. It Is not the Intent of the State Flra Marshal to endorse any one specific product, device or methodology. DelCrlptlon of Opamlon of the Haaly Clean Air Seperetor TM: The Healy Systems, Inc., Model 9961 Healy Clean /IIJr Separator"' Is e stand-alone, completely mechanical device that assists In controlling the gasoline vapor emissions from a gasoline dispensing facility. It consists of a 400-gaUon stOl'llge vessel with Integral bladder and associated valving. It Is connected to the ullage space of the GDF storage tanks via the venting systam of the under ground storage tanks. During normal operation of the GDF, with today's concentration of ORVR vehicles approximating 20%, the storage tank ullage space wtU usually operate In the "O- to negative (up to s• WC PN crecklng pressure) pressure range. During" dosed" periods of the GDF, the ullage pressure wlll usuaHy begin to Increase due to vapor growth Inherent In th11 process of introducing air Into the usrs. If the pressure goes slightly abo\'.e atmospheric the vapor from the usrs Will flow Into the Internal bladder. Conversely, when ORVR refueling begins and the UST pressure falls below atmospheric, the vapor Internal to the bladder wHI be drawn back Into the UST unUI the bladder Is fuHy collapsed waiting for the next cycle. The Clean Air Separator"' In over two and one half years (Installed late September of 2002) of being In operation at our C.A.R.B. test site In Sacramento has been evaluated repeatedly to see If there Is any liquid condensaUon In either the bladder or the space between Iha Inner wau ot t,e vessel and outer wall of the bladder. To date there has been no liquid found In either area.