04-17-2008 Residential Permit Permit No: CB073047
Building Inspection Request Line (760) 602-2725
Job Address: 1990 MARCASITE PL CBAD
Permit Type: RESDNTL Sub Type:
Parcel No: 2132913300 Lot#:
Valuation: $300,348.00 Construction Type:
SFD
69
VN
Status:
Applied:
Entered By:
ISSUED
12/11/2007
JMA
Occupancy Group:
04/17/2008
Reference #: CT 04-09 Plan Approved:
# Dwelling Units: Structure Type: SFD Issued: 04/17/2008
Bedrooms: 4 Bathrooms: 4 Inspect Area:
Project Title: TRIESTE PL 3: PHS 5 -2742SF LV Orig PC#:
598SF GAR/162SF DECK/162SF LOG/70SF PORCH Plan Check#:
PC 06-35
PC07-75
Applicant:
WARMINGTON HOMES
701 PALOMAR AIRPORT RD
CARLSBAD CA 92011
931-4766
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
$1,271.61
$0.00
$826.55
$0.00
($66.12)
$30.03
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$7,702.00
D1
$0.00
$0.00
Owner:
WARMINGTON TRIESTE ASSOCIATES LP
C/0 WARMINGTON HOMES CALIFORNIA
3090 PULLMAN ST #A
COSTA MESA CA 92626
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (310554_1)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $27,3g1.53 Total Payments To Date: $27,391.53 Balance Due:
FINAL APPROVAL
Inspector: Date: Clearance: \1 z , \ a:;.i I
$0.00
$225.00
$7,188.00
$3,618.63
$5,466.33
$0.00
$0.00
$0.00
$750.00
$0.00
$0.00
$252.00
$60.00
$67.50
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$27,391.53
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a}, and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar J3ny subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
f x i n fw i h lim' 11 i I
City of Carlsbad Bldg Inspection Request
For: 01/21/2009
Permit# CB073047 Inspector Assignment: MC ---
Title: TRIESTE PL 3: PHS 5 -2742SF LV
Description: 598SF GAR/162SF DECK/162SF LOG/70SF PORCH
Sub Type: SFD Type: RESDNTL Phone: 7604271926
Job Address: 1990 MARCASITE PL
Suite: Lot: 69
Location: Inspector: (vtL -~---
OWNER WARMINGTON TRIESTE ASSOCIATES LP
Owner: WARMINGTON TRIESTE ASSOCIATES LP
Remarks:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Act
n
*
Comments
Requested By: KYLE
Entered By: CW
Pkf"~t> :lclU..-'t"A-"6 Af" :f'."l><TUIZBS •IL..
Nt,t-l-M""'.'t" Al-UC f'\\?J,,,Ua ~ A,,f"
Comments/Notices/Holds
Associated PCRs/CVs Original PC# PC 06-35
lns12ection HistO!}'.
Date Description Act lnsp Comments
01/07/2009 89 Final Combo NR MC PER CONTRACTOR AFTER STOP
10/28/2008 39 Final Electrical AP MC EMR ONLY, OK TO RELEASE METER
09/05/2008 82 Drywall/Ext Lath/Gas Test AP PC
08/29/2008 16 Insulation AP MC
08/27/2008 84 Rough Combo AP MC MINOR PICK UP
08/22/2008 84 Rough Combo co PC COMPLETE ALL TRADES -COMPLETE LA TH
08/04/2008 13 Shear Panels/HD's AP MC OK TO WRAP
07/11/2008 15 Roof/Reroof AP MC
05/29/2008 81 Underground Combo AP MC RECEIVED SOILS, PT & BLDG PLACEMENT REPORTS, UFER GRND
OK
05/19/2008 21 Underground/Under Floor AP MC BACK FLOW PREVENTER
05/19/2008 22 Sewer/Water Service AP MC
Chi Of Carlsbad
~ ·; Flnal B1Hdln1 11111cuon
~ ~·-..
Dept: B_uikl
Plan Check#:
Permit #:
Project Name:
Address:
Contact Person:
Sewer Dist:
lanning CMWD St Lite Fire
CB073047
TRIESTE PL 3: PHS 5 -2742SF LV
598SF GAR/162SF DECK/162SF LOG/?0SF PORCH
1990 MARCASITE PL
Phone:
LC Water Dist: CA
Date:
Permit Type:
Sub Type:
Lot: 69
DEC -1 2008
I
_ 11/26/2008
RESDNTL
SFD
..........................................................................................................................................................
Inspected ~~ Date 11/u;/46 By: &~ Inspected: Approved: x Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __ .......................................................................................................................................................... ,
Comments: ______________________________ _
Southern California Soil and Testing, Inc.
6280 Riverdale Street, San Diego, CA 92120 (619) 280-4321
P.O. Box 600627, San Diego, CA 92160-0627
83-740 Citrus Avenue, Suite G, Indio, CA 92201 -3438 (760) 77 5-5983
Concrete (4x8) Compressive Strength Test Report
FileNumber: 0612215
Project Title: Trieste at La Costa Greens PTCC Phase: 5
Project Location: l 990 Marca site P lace
Architect: n/a
Engineer: WM Hazmalhalch Permit No: CB07-3047
Contractor: Warmington Plan File No:
Location In Structure: Lot: 69 Northwest Corner of Slab
Material Supplier: Superior
Mix Designation: 375p
Admixture(s): Pozzolan
Time In Mixer:
Air Content: (ASTM C173/C231)
Air Temp:
Truck Number:
Samples Made By: (ASTM C31)
Laboratory Number
Mark On Samples
Date Made
Date Received
Date Tested
Diameter. Inches
Area, Square Inches
Maximum Load, Pounds
Compressive Strength, psi
Age Tested
Required 28 Day Strength, psi
Fracture Type
60 minutes
70 degrees F
481
LR
0870705
LOT 69
5/30/2008
6/2/2008
6/6/2008
4.00
12.57
53890
4290
7 Days
4500
Slump inches: (ASTM C143)
Unit Weight Plastic/Dry, pcf: (ASTM
C138/C567)
Concrete Temp: (ASTM C1064)
Ticket Number:
Samples Tested By:
0870706 0870707
5/30/2008 5/30/2008
6/2/2008 6/2/2008
6/27/2008 6/27/2008
4.00 4.00
12.57 12.57
80050 79950
6370 6360
28 Days 28 Days
4500 4500
1 2
4.00
I
76 degrees F
56048
GEN CN
Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable
ASTM C39 standards. This agency makes no other warranties express or implied.
Fracture Type: 1 -Reasonably well formed cones on both ends, less than 1 in. of cracking through caps: 2 -Well formed cone on
one end, vertical cracks running through caps.no well defined cone on other end; 3 -Columnar vertical cracking through both ends,
no well formed cones; 4 -Diagonal fracture with no cracking through ends; 5 -Side fracture at top or bottom (occur commonly with
unbonded caps); 6 -Similar to type 5 but end of cylinder is pointed.
Distribution:
(1) City of Carlsbad -Building Inspection Department
Reviewed By: / ______.::----~ -----(1) Warmington Homes California Gordon T.M. Woodard RCE # 60481
GEOCON Q __ Q ·--
< I NC]ORPO R ·ATED GEOTECHNIC~tCONSULTANTS ~~
6 <T6f) FLANDERS DRIVE ■ SAN DIEGO , CALIFORNIA 92121·297 4 ■ TEL 1858) 558·6900 ■ FAX 1858) 558·6159 •
FOUNDATION OBSERVATION REPORT
PROJECT NAME : Tc, e. G.::.(! f:~ s. -W .,,_.c.r-,, , "'i , r -, .-J
LOCATION : l ,,r ~ l l, -1/1 ,
FOUNDATION LOCATION (if not entire building)
PLAN FILE NO.
FOUNDATION TYPE :
0 faONVENTIONAL
[3" POST· TENSIONED
'¥ I -~ ,_A.-..
PROJECT NO. o c,. ~1° 3 -SZ · .c...i.o
DATE : __ .s_· _2 _2_-_o_<s ____ _
0 ADDITIONAL OBSERVATION REQUIRED
~SST ANTIAL CONFORMANCE
-. • PURPOSE OF OBSERVATION \-', ',O M D,.fZ GA,.~ l$ Fl-,
~y erify soil conditions exposed are similar to those anticipated
ct' Verify footing excavations extend to minimum depth recommended in soil report
D Verify foundation reinforcement complies with minimum recommended in soil report
D ~fy slab reinforcement, sand bedding and moisture barrier comply with minimum -recommended in soil report
o'\,erify footings have been extended to an appropriate bearing strata
D Other
• APPLICABLE SOIL REPORT :
\ __ ,-~...,~•--6~--t..~e~a~,_,_..s. __ ~1_-_1~7 ___________________ DATE : _____ _
TITLE : -~(,,,.~'-·-' -~--"~·-•~_L,_1_~;_,,_1-_, ... _• __ f..._•'r _T_--+-_v_. ~ ____ L_-·'-__ L._-_· _r 4=~--
• SOIL REPORT RECOMMENDATIONS BASED ON:
cri'xpansion Condition D VERY LOW
-/ ... < I,=.'' IY'Fill Geometry ------------------------------------
0 LOW ~EDIUM 0 HIGH 0 VERY HIGH
□ Other : ____ ___;;l,,'--"'L'-----=t..,_e, ____ c:,,,,. __ -r_~,LL-===----1-/---G. __ '1 __ -_C....;::__-r_-'--_J.__'-----------
• MINIMUM FOUNDAT~ON ECOMMENDATIONS :_ .....,.,., ~L c..,,,..r .J.l.-,_ 'I
D Footing Depth : 12 Inches ~1:'5'~Inches D 24 Inches OTH§.!3 1-, -:.. 2-'-' >-t '" 2. 3
Footing Reinforcement: D No.4 T&B D 2-No.4 T&B D 2-No.5 T&B c:YPost-Tensioned OTHER : _____ _
Interior Slab Reinforcement : D 6x6-10/10 D 6x6-6/6 D No.3@24Inches D No.3@18Inches .£1 Post-Tensioned
Slab Bedding Material and Thickness : ____________ Vapor Barrier :
Foundation Width : 'Z ,_ ' ,_,,
• OBSffivATIONS:
d's~bstantial conformance with Soil Reports (see "Purpose of Observation")
~stantial conformance with Foundation Plans. Identify : '"'>;-~ r:~·-) ..1o--, Q,,.__ . ....,-5 ... ....J
~ 2~,.3
0 Other
• COMMENTS : ----------------------------------
NOTE : IT IS ASSUMED THAT All FOOTING EXCAVATIONS Will SE QEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOil MOISTURE CONTENT Will SE MAINTAINED
-r7~ cc_--:i-t:5 #= .5:;-2-
v FIELD COPIES TO GEOCoN REPRESENTATIVE
PI.ANNINC
ENCtNEERINC
SURVEYING
WH~MlNGfON-SAN DIEGO
HUNSAKER
&ASSOCIATES
S A. N O I t C 0. l N r.
NO.507 P.2/2.
IIMNE
LOSANGEL£l May 14, 2008
RIVERSIDE
SAN OIECO
Al:.IZONA
DAVE HAMMAR
LEX WJlllMAN
ALIS/\ VIALPANDO
DAN SMITH
RAY MAfCTIN
CHUC~ CATER
!)'07 WOiples Sltc!tl
SMI Oic•in, CA 92121
HVil\l 5!in...4JIIQ l'H
(MIU 55ff-1414 FX
www.t;uns:tlccrSO.a,rn
11ifn@Hu"~1kl'fSO.cnm
City of Carlsbad
Engineering Department
1635 Faraday Avenue
Carlsbad, CA 92008-7314
Re: Building Form Certification
La Costa Greens Neighborhood 1.17
Carlsbad Tract 04-09/PUD 04-0BA
Drawing No. 429-2C
Lots 45 through 49 and 64 through 71
Dear City Inspector:
Please be advised the building foundation forms iire in conformance with the
precise grading plans as to horizontal and vertical location. All locations checked
were found to be within O 1 of a foot horizontally and vertically per the precise
grading plans.
Sincerely,
o,(b Sm~ Ls 68'<
Hunsaker & Associates San Diego, Inc.
TK ~I ~.~1C7~011~'clll dOG•
\lrO a107·JOI •114120111 IP U "-"'
0 H .. s. BOlTJNG
0$.1\APP. NO.: