Loading...
HomeMy WebLinkAbout1991 LANCEWOOD LN; ; CB044304; Permit12-11-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB044304 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1991 LANCEWOOD LN CBAD COMMIND Sub Type COMM 2550121700 Lot# 0 $692,11600 Construction Type VN Reference* SDP9801A LA COSTA GLEN-7523 SF MECHANIC CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Applicant CONTINUING LIFE COMMUNITIES LLC 1940LEVANTEST CARLSBAD CA 92009 Status Applied Plan Approved Issued Inspect Area Plan Check* ISSUED 11/30/2004 Entered By 05/04/2005 05/04/2005 RB PC040105 RMA Owner CONTINUING LIFE COMMUNITIES LLC 1940LEVANTEST CARLSBAD CA 92009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $2,282 29 $000 $1,48349 $000 $000 $145 34 $000 $000 $000 $000 $000 $000 $000 $6000 $000 . $000 $000 Meter Size Add'l Reel Water Con Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFF (4305540) License Tax (3104193) License Tax (43041 93) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $7,724 61 $12,59651 $000 $000 $000 $1 ,274 00 $000 $000 $000 $000 $000 $000 $000 $000 77 $25,566 24 Total Fees $25,566 24 Total Payments To Date $25,566 24 Balance Due $000 BUILDING PLANh _\L_IN STORAGE ATTACHED Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 08-31-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB044304 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title Applicant 1991 LANCEWOOD LN CBAD COMMIND Sub Type COMM 2550121700 Lot# 0 Status ISSUED $692,11600 Construction Type VN Applied 11/30/2004 Reference* SDP9801A Entered By LA COSTA GLEN-7523 SF MECHANIC Plan Approved 05/04/2005 CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Issued 05/04/2005 Inspect Area RB Plan Check* PC040105 Owner RMA CONTINUING LIFE COMMUNITIES LLC 1940LEVANTEST CARLSBAD CA 92009 CONTINUING LIFE COMMUNITIES LLC 1940LEVANTEST CARLSBAD CA 92009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $2,282 29 $000 $1,48349 $000 $000 $145 34 $000 $000 $000 $000 $000 $000 $000 $6000 $000 $000 $000 Meter Size Add'l Reel Water Con Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFF (4305540) License Tax (3 104 193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $000 $000 $000 $7,72461 $12,59651 $000 $000 $000 $1,27400 $000 $000 $000 $000 $000 $000 $000 $000 99 $25,566 24 Total Fees $25,566 24 Total Payments To Date $25,566 24 Balance Due BUILDING PLANS IN STORAGE ATTACHED $000 Inspector FINAL APPROVAL Date /fr-V-'fr Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired September 28, 2006 TO Jon Kawada, IMA Design, phone (949) 250-0023, fax (949) 250-0043 Jack Guevara, Costa Verde Landscape, phone (858) 205-7234, fax (714) 668- 9990 Christer Westman, Senior Planner Christine Wauschek, Building Department Pete Dreibelbis, Senior Building Inspector Pat Kelley, Building and Code Inspector Michele Masterson, Management Analyst Michelle Gregory, Senior Office Specialist FROM Michael Elliott, Landscape Architect Consultant to the City of Carlsbad (760) 944-8463 PELA file 52A - La Costa Olen Central Plant - Insp2 REFERENCE 2nd Landscape Inspection PROJECT La Costa Glen - Central Plant Project Number CT92-08 Drawing Number___349-3S Central Plant -~TWTtjaicgwood Lane - CB044304 TheJ^flowmg items were noted as deficient and In need of /Central Plant - 1991 Lanccwood Land - CB044304 1 Complete all items for La Costa Glen Building D per infection report for that building 2 Permit card was signed ic contractor/developer is reminded that irngatwrTfecord drawings (as-builts) will be required to be completed and approved byJheJCriy'pflor to signing off the last unit of the project City if Carlsbad Final Building Inspection SCP 2 1 2006 Dept: Building Egoy Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected Bv Inspected Bv Inspected Bv PC040105 pwflrtrig Planning CMWD StLite Fire I tv iVuV.v! u '.'^"fv CB044304 LA COSTA GLEN-7523 SF MECHANIC CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & 1991 LANCEWOOD LN SCOTT LC S/tt/ Phone1 7604978606 Water Dist. O / Date _ . ) Inspected ?/&?/& Date Inspected Date Inspected Date Permit Type Sub Type STORAG Lot 0 '^ Approved v Approved Approved 09/2 1 /2ID06" • COMM1ND COMM Disapproved Disapproved Disapproved Comments City of Carlsbad Final Building Inspection Dept. Building Engineering Planning CMWD St Lite (Fire~ Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected / By /- \ Inspected Bv Inspected Bv PC040105 CB044304 LA COSTA CENTRAL GLEN-7523 SF MECHANIC PLANT,OFFICE,LAUNDRY,MAINT & 1991 LANCEWOODLN SCOTT LC o-y "3 f-Js ,x ' I Phone 7604978606 Water Dist 0 Date / / Inspected ///7/<3 / ' Date Inspected Date Inspected Date Permit Type • Sub Type STORAG Lot 0 Asf^_ Approved £/^-^ Approved Approved 12/05/2006 COMMIND COMM Jiisapproved Disapproved Disapproved Comments City of Carlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Plan Check # Permit # Project Name Address Contact Person Sewer Olst Inspected Bv Inspected Bv Inspected Bv PC040105 CB044304 Date 09/21/2006 Permit Type COMMIND LA COSTA GLEN-7523 SF MECHANIC Sub Type COMM CENTRAL PLANT.OFFICE, LAUNDRY, 1991 LANCEWOOD LN MAINT & STORAG Lot 0 SCOTT Phone 7604978606 LC Water Dist O j\ ff Date M Wft»* Inspected 1 I W \ Date Inspected Date Inspected I fi(f Approved vL^ Disapproved Approved Disapproved Approved Disapproved Comments City ol Carlsbad Final Building Inspection Dept Building Engineering Plarming CMWD St Lite Fire Plan Check # Permit # Project Name Address Contact Person Sewer Dist Inspected By Inspected By Inspected Bv PC040105 CB044304 LA COSTA GLEN-7523 SF MECHANIC CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & 1991 LANCEWOODLN SCOTT Phone 7604978606 LC Water Dist O Date Inspected Date Inspected Date Inspected Date Permit Type Sub Type STORAG Lot 0 Approved Approved Approved 12/05/2006 COMMIND COMM Disapproved Disapproved Disapproved Comments o/o Mo '—- Inspection List Permit* CB044304 Type COMMIND COMM Date Inspection Item 12/11/2007 19 12/11/2007 19 01/24/2007 89 12/06/2006 89 12/05/2006 89 11/09/200689 11/06/2006 17 11/02/2006 14 11/02/200624 11/02/200634 11/02/200644 11/01/2006 14 11/01/200624 11/01/2006 34 11/01/200644 10/31/2006 84 10/04/2006 89 09/27/2006 89 09/26/2006 89 09/25/2006 89 09/21/2006 89 09/19/200689 09/18/200689 09/15/200689 09/05/2006 84 09/01/2006 14 09/01/2006 84 08/30/2006 17 08/30/2006 84 08/29/2006 17 08/23/2006 84 08/16/2006 29 08/15/2006 23 08/15/200629 08/11/200623 08/11/200629 08/10/2006 23 08/09/2006 23 08/07/2006 17 08/03/2006 14 08/03/2006 1 7 Final Structural Final Structural Final Combo Final Combo Final Combo Final Combo Interior Lath/Drywall Frame/Steel/Boltmg/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Frame/Steel/Bolting/Weldin Rough/Topout Rough Electric Rough/Ducts/Dampers Rough Combo Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Final Combo Rough Combo Frame/Steel/Boltmg/Weldin Rough Combo Interior Lath/Drywall Rough Combo Interior Lath/Drywall Rough Combo Final Plumbing Gas/Test/Repairs Final Plumbing Gas/Test/Repairs Final Plumbing Gas/Test/Repairs Gas/Test/Repairs Interior Lath/Drywall Frame/Steel/Boltmg/Weldin Interior Lath/Drywall Inspector Act - RB RB RB RB TP TP TP TP TP TP RB RB RB RB RB RB RB RB RB RB RB RB ; RB RB RB RB RB RB RB RB RB RB RB TP TP RB RB RB MC MC Rl AP NR CO NS NS AP AP we AP AP CO AP CO we NS Fl CO CO NR NR CO NS NS AP CO CO we CO PA CO AP CO CO AP we PA NR PA AP AP LA COSTA GLEN-7523 SF MECHANIC CENTRAL PLANT,OFFICE,LAUNDRY,MAI Comments No activity for quite a while, OK to fin need Eng Sign off MISSING EMERGENCY BACK UP LIGHTING WAIT FOR R B ROOMS 2ND FLR WALLS 2ND FLR WALLS EXHST @ REST RM SEE NOTICE WILL DO LATER rolled to Wednesday AGAIN SEE NOTICE 2nd time - see notice attached ON CORRECTIONS SEE NOTICE ATTACHED 3RD TIME - T-BAR PAY REFEE 2ND TIME ON T-BAR - SEE NOTICE ATTACHED missing fire caulking @ mech Rm ON T-BAR SEE NOTICE ATTACHED FOR GAS METER RELEASE working early (6 23am) no msp 24 HR GAS TEST STARTED 24 HR TEST NEED 24 HR TEST OK @ EXTERIOR CLOSET RMS SOFFIT FRAMING @RM 113&122 HARD LID @RM 101, 102 HALL, 112, 115 07/27/200617 Interior Lath/Drywall RB PA AND 116 EMPLOYEES LOUNGE HARD LID OK Tuesday, December 11, 2007 Page 1 of 3 07/12/2006 17 07/10/2006 17 07/10/200684 06/29/2006 14 06/29/2006 17 06/27/2006 17 06/27/2006 22 06/23/2006 17 06/19/2006 17 06/19/2006 34 06/14/2006 39 06/12/2006 14 06/12/2006 17 06/12/2006 18 06/12/200639 06/08/2006 17 06/08/2006 84 06/01/2006 24 05/05/2006 84 05/01/2006 14 05/01/2006 24 05/01/2006 34 04/26/2006 24 04/13/200684 04/11/2006 15 04/11/200623 03/02/2006 15 02/24/2006 61 02/24/2006 62 02/21/2006 15 02/17/2006 15 02/09/2006 63 02/02/2006 63 02/02/2006 66 02/01/2006 63 02/01/2006 66 01/24/2006 12 01/18/2006 66 01/09/2006 66 01/06/2006 11 01/05/2006 11 01/04/2006 66 01/04/2006 66 12/22/2005 62 12/22/200566 Interior Lath/Drywall Interior Lath/Drywall Rough Combo Frame/Steel/Bolting/Weldm Interior Lath/Drywall Interior Lath/Drywall Sewer/Water Service Interior Lath/Drywall Interior Lath/Drywall Rough Electric Final Electrical Frame/Steel/Boltmg/Weldm Interior Lath/Drywall Exterior Lath/Drywall Final Electrical Interior Lath/Drywall Rough Combo Rough/Topout Rough Combo Frame/Steel/Bolting/Weldm Rough/Topout Rough Electric Rough/Topout Rough Combo Roof/Reroof Gas/Test/Repairs Roof/Reroof Footing Steel/Bond Beam Roof/Reroof Roof/Reroof Walls Walls Grout Walls Grout Steel/Bond Beam Grout Grout Ftg/Foundation/Piers Ftg/Foundation/Piers Grout Grout Steel/Bond Beam Grout PD RB RB RB RB RB RB RB RB RB RB RB RB RB RB RB RB RB PD RB RB RB RB PD PD PD RB TP TP RB RB PD RB RB RB RB RB RB PY RB RB RB RB PS PS PA PA we CO AP PA PA NS NR PA CO CO CO AP we CO CO AP AP CO CO CO NR CA AP AP PA AP we CO NS AP we AP we CO PA AP AP AP CO PA PA AP AP FIRE CAULKING @ CEILING FOR RMS 102, 101, 115&116 CEILING JOISTS INSP WALLS & LID @ RM 102 & 106 SEE NOTICE ATTACHED WATER SERVICE ONLY OK NEED CORRECTIONS FROM FRMG DONE 1ST EMR ON TESTING EQUIPMENT ONLY SEE NOTICE STILL MISSING CORRECTIONS FRM 5-1 06 SEE NOTICE ATTACHED COMPLETED WITHOUT INSP NEEDCORR FROM 5-1- & 5-12 COMPLETED MAINT BLDG SEE NOTICE ATTACHED MISSING TOP OUT TEST GAS IN PLANT SHEATING& TRUSS OK @ MECHANICAL BLDG RETAINING & SCREEN WALLS WALL L L ON ROOF NAILING ftgs FOR TOP LIFT TOP LIFT 4TH LIFT @ CENTRAL PLANT OK ON 3RD FLOOR LIFT SCREEN WALL pad for soft water tanks FOR TANK PAD - NEED SPEC INSP REPORT 2ND LIFT MAINTANCE BLDG 3RD LIFT @ COOLING TOWER NOTED ON PLANS 2ND LIFT OK W/0 CITY INSP @ COOLING TOWER NOTED ON PLANS 12/21/2005 11 Ftg/Foundation/Piers Tuesday, December 11, 2007 RB WC Page 2 of 3 12/21/2005 12 12/21/200565 12/13/2005 11 12/12/200566 12/06/2005 11 12/06/2005 12 12/05/2005 11 12/05/200566 11/30/200562 11/23/2005 11 11/23/2005 13 11/23/2005 14 11/23/2005 15 11/23/200524 11/23/2005 34 11/23/200544 11/21/2005 11 11/21/200561 11/15/200566 11/08/200581 10/28/2005 11 10/27/2005 12 10/25/2005 11 10/25/2005 12 09/27/2005 1 1 09/16/200541 09/14/2005 22 09/14/2005 31 09/12/2005 22 09/09/2005 22 09/07/2005 22 08/15/200521 08/09/2005 31 08/02/2005 31 08/01/2005 21 08/01/2005 41 07/25/2005 21 07/25/2005 22 Steel/Bond Beam Retaining Walls Ftg/Foundation/Piers Grout Ftg/Foundation/Piers Steel/Bond Beam Ftg/Foundation/Piers Grout Steel/Bond Beam Ftg/Foundation/Piers Shear Panels/HD's Frame/Steel/Bolting/Weldm Roof/Reroof Rough/Topout Rough Electric Rough/Ducts/Dampers Ftg/Foundation/Piers Footing Grout Underground Combo Ftg/Foundation/Piers Steel/Bond Beam Ftg/Foundation/Piers Steel/Bond Beam Ftg/Foundation/Piers Underground Ducts Sewer/Water Service Underground/Conduit-Wirin Sewer/Water Service Sewer/Water Service Sewer/Water Service Underground/Under Floor Underground/Conduit-Wirin Underground/Conduit-Wirin Underground/Under Floor Underground Ducts Underground/Under Floor Sewer/Water Service RB RB PS PS PS PS PS PS PS JM JM JM JM JM JM JM TP TP PS PS PC PC PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PA WC CO AP AP AP CO NR AP CO NR NR NR NR NR NR WC AP CO AP CO PA PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS CO CO AP AP AP AP CO CO PA AP AP AP PA PA AP AP SEE JOB PLANS MISSING STEEL noted on plans HILITED ON PLANS YELLOW 2ND LIFT HILITED YELLOW HILITED PINK PAD FTGS NOT PER PLAN - NEED SOILS LETTER 1ST LIFT CMU WALL AT CENTRAL PLANT WRONG DETAIL NEED SI REPORT FOR 5IN SLAB COOLING TOWER PADS SEE SPEC INSP REPORT POURED BEFORE MY APPROVAL PERIMETER FTG & PIERS - SEE HIGH LITED PLAN @ CENTRAL PLANT MISSING SLAB DOWELS ELEV PIT FLR & WALLS OVER PHONE STORNM DRAIN SAME AS 9/9/05 NO FALL MISSING CO NOT SHADED STORM DRAIN YELLOW HILITE YELLOW HILITED ORANGE HILITE YELLOW HILITE YELLOW HYDRO Tuesday, December 11, 2007 Page 3 of 3 City of Carlsbad Bldg Inspection Request For 12/11/2007 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks No activity for quite a while, OK to fin Phone Inspector Total Time CD Description 19 Final Structural Requested By CHRISTINE Entered By CHRISTINE Act CommentsAct Comments/Notices/Holds Associated PCRs/CVs Original PC# PC040105 PCR06184 ISSUED I.A COSTA GLEN-REVISIONS TO. BLDGS E F.G&H-BULLETIN 6 PCR05141 ISSUED I.A COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN 13UM.KTIN 4 ARCH RI-JVISIONS PCR05223 ISSUED I.A COSTA GLEN STEI-L/CONCRETI- STAIR SUBMITTAL PCR06008 ISSUED LA COSTA GLEN CENTRAL PLANT, DEKI-ERED TRUSS SUBMITIAL PCR06072 ISSUED I.A COSTA GLEN 2ND H.K TI ?</• CENT PLT BULLETIN #5 Inspection History Date Description Act 01/24/2007 89 Final Combo NR 12/06/2006 89 Final Combo CO 12/05/2006 89 Final Combo NS 11/09/2006 89 Final Combo NS TP 11/06/2006 17 Interior Lath/Drywall AP TP 11/02/2006 14 Frame/Steel/Boltmg/Welding AP TP 11/02/2006 24 Rough/Topout WC TP 11/02/2006 34 Rough Electric AP TP 11/02/2006 44 Rough/Ducts/Dampers AP 11/01/2006 14 Frame/Steel/Boltmg/Weldmg CO 11/01/2006 24 Rough/Topout AP Insp Comments RB need Eng Sign off RB MISSING EMERGENCY BACK UP LIGHTING RB TP WAIT FOR R B TP RB RB ROOMS 2ND FLR WALLS 2ND FLR WALLS EXHST @ REST RM SEE NOTICE City of Carlsbad Bldg Inspection Request For 12/06/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7604978606 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By SCOTT Entered By CHRISTINE Act Comment '* Comments/Notices/Holds Associated PCRs/CVs Original PC# PC040105 PCR06184 PENDING I.A COSTA GLEN-REVISIONS TO, BLDGS E.F,G&H-BULLETIN 6 PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED I.A COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4 ARCH REVISIONS PCR05223 ISSUED I.A COSTA GLEN STEEL/CONCRIHT. STAIR SUUMITTAL PCR06008 ISSUED LA COSTA GLEN CENTRAL PLANT DEITERED TRUSS SUBMIT1AL PCR06072 ISSUED LA COSTA GLEN 2ND FLR Tl ft CENT PLT BULLETIN #5 Inspection History Date Description Act 11/09/2006 89 Final Combo NS 11/06/2006 17 Interior Lath/Drywall AP 11/02/2006 14 Frame/Steel/Boltmg/Welding AP 11/02/2006 24 Rough/Topout WC 11/02/2006 34 Rough Electric AP Insp Comments TP WAIT FOR R B TP TP ROOMS 2ND FLR WALLS TP TP 2ND FLR WALLS -f City of Carlsbad Bldg Inspection Request For 11/01/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks rolled from Tuesday Phone Inspector Total Time Requested By CHRISTINE Entered By CHRISTINE CD Description Act Comment 14 Frame/Steel/Bolting/Weldmg 24 Rough/Topout fTf 34 Rough Electric 44 Rough/Ducts/Dampers ll/ cb Comments/Notices/Hold Associated PCRs/CVs Original PC# PC040105 PENDING LA COSTA GLEN-REVISIONS TO BLDGS E I- G&H-BULLETIN 6 LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE , STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT, DEITERED TRUSS SUBMITIAL LA COSTA GLEN, 2ND FLR TI @ CENT PLT , BULLETIN #5 PCR06184 PCR05141 ISSUED PCR05143 ISSUED PCR05154 ISSUED PCR05217 ISSUED PCR05223 ISSUED PCR06008 ISSUED PCR06072 ISSUED Inspection History Date Description Act 10/31/2006 84 Rough Combo " NS 10/04/2006 89 Final Combo Fl 09/27/2006 89 Final Combo CO 09/26/2006 89 Final Combo CO 09/25/2006 89 Final Combo NR Insp Comments RB rolled to Wednesday RB RB AGAIN SEE NOTICE RB 2nd time - see notice attached RB CITY OF CARLSBAD BUILDING DEPARTMENT DATE LOCATION NOTICE PERMIT NO (760) 602-2700 1635 FARADAY AVENUE V- FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? FOR FURTHER INFORMATION, CONTACT J YES PHONE BUILDING II CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 10/04/2006 PermiW CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7604978606 Inspector Total Time Requested By SCOTT Entered By KAREN CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Comment Comments/Notice Associated PCRs/CVs Original PC# PC040105 PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA GLEN STEEUCONCRETE , STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBM1T1AL LA COSTA GLEN, 2ND FLR TI @ CENT PLT , BULLETIN #5 PCR06008/ ISSUED PCR06072/ ISSUED Inspection History Date Description Act 09/27/2006 89 Final Combo CO 09/26/2006 S^Etnal Combo CO 09/25/2006 89 Final CBR^O NR 09/21/2006 89 Final Combo NR 09/19/2006 89 Final Combo CO 09/18/2006 89 Final Combo NS Insp Comments RB AGAIN SEE NOTICE RB 2nd time - see notice attached RB RB ON CORRECTIONS RB SEE NOTICE ATTACHED RB City of Carlsbad Bldg Inspection For 09/27/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7604978606 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By SCOTT Entered By CHRISTINE Act Comment Cornments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Associated PCRs/CVs Original PC# PC040105 LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT BULLETIN fr3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT DEFFERED TRUSS SUBMITIAL LA COSTA GLEN, 2ND FLR TI @ CENT PLT , BULLETIN US Inspection History Date Description 09/25/2006 89 Final Combo 09/21/2006 89 Final Combo 09/19/2006 89 Final Combo 09/18/2006 89 Final Combo 09/15/2006 89 Final Combo 09/05/2006 84 Rough Combo Act NR NR CO NS NS AP Insp RB RB RB RB RB RB Comments ON CORRECTIONS SEE NOTICE ATTACHED NOTICECITY OF CARLSBAD (760)602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE *" ' TIME PERMIT NO -^t^ \—I FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? l_J YES FOR FURTHER INFORM/mON, CONTACT . PHONE ~COOE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 09/26/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7604978606 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By SEAN Entered By JANEAN Act Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# PC040105 PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA.GLEN STEEL/CONCRETE STAIR SUBMITTAL PCR06008 ISSUED LA COSTA GLEN CENTRAL PLANT DEFPCRED TRUSS SUBMIT1AL PCR06072 ISSUED LA COSTA GLEN, 2ND FLRT1 @ CENT PIT BULLETIN US Inspection History Date Description Act 09/21/2006 89 Final Combo NR 09/19/2006 89 Final Combo CO 09/18/2006 89 Final Combo NS 09/15/2006 89 Final Combo NS 09/05/2006 84 Rough Combo AP 09/01/2006 14 Frame/Steel/Boltmg/Weldmg CO Insp Comments RB ON CORRECTIONS RB SEE NOTICE ATTACHED RB RB RB RB 3RD TIME - T-BAR PAY REFEE CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME_ LOCATION PERMIT NO ^ FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE'' L J YES FOR FURTHER 1NFOR1MATION?SDNTACT PHONE BUILDING ifJSI CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 09/19/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7604978606 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By NA Entered By CHRISTINE Act Comment Com ments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRA!, PLANT REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN U3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4 ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE , STAIR SUBMfTTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAL LA COSTA GLEN 2ND FUR Tl @ CENT PLT , BULLETIN #5 Date 09/15/2006 09/05/2006 09/01/2006 09/01/2006 08/30/2006 08/30/2006 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Description 89 Final Combo 84 Rough Combo 14 Frame/Steel/Bolting/Weldmg 84 Rough Combo 17 Interior Lath/Drywall 84 Rough Combo Act NS AP CO CO Insp RB RB RB RB WC RB CO RB Comments 3RD TIME - T-BAR PAY REFEE 2ND TIME ON T-BAR - SEE NOTICE ATTACHED CITY OF CARLSBAD BUILDING DEPARTMENT NOTICE (760)602-2700 1635 FARADAY AVENUE DATE LOCATION PERMIT NO d 6 TIME FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION TEE DUE? L^: YES FOR FURTHER INFORMATION, CONTACT _._ PHONE "BUILDING ifi?PFffoR CODE ENFORCCMCNT OFFICER City of Carlsbad Bldg Inspection Request For 08/31/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks ABOVE CEIL Phone 7604790229 Inspector Total Time CD Description 14 Frame/Steel/Boltmg/Welding Act Comment J "*"" Comments/Notices/Hold Requested By SEAN Entered By JANEAN - I ~-f PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN *3 STRUCT AND PLUMBING I..A COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBM1TTAL LA COSTA GLEN CENTRAL PLANT, DEI'FERED TRUSS SU13M1TIAL LA COSTA GLEN, 2ND FLR TI © CENT PLT BULLETIN U5 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Date Description Act 08/29/2006 17 Interior Lath/Drywall PA 08/23/2006 84 Rough Combo CO 08/16/2006 29 Final Plumbing AP 08/15/2006 23 Gas/Test/Repairs CO 08/15/2006 29 Final Plumbing CO 08/11/2006 23 Gas/Test/Repairs AP 08/11/2006 29 Final Plumbing WC 08/10/2006 23 Gas/Test/Repairs PA 08/09/2006 23 Gas/Test/Repairs NR 08/07/2006 17 Interior Lath/Drywall PA 08/03/2006 14 Frame/Steel/Bollmg/Welding AP 08/03/2006 17 Interior Laln/Drywall AP Insp Comments RB missing fire caulking @ mech Rm RB ON T-BAR SEE NOTICE ATTACHED FOR GAS METER RELEASE working early (6 23am) no msp RB RB RB TP TP RB RB RB MC MC 24 HR GAS TEST STARTED 24 HR TEST NEED 24 HR TEST OK © EXTERIOR CLOSET RMS SOFFIT FRAMING @ RM 113 & 122 HARD LID @ RM 101 102 HALL 112 115 AND 116 CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION. PERMIT NO nFOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? L I YES FOR FURTHER IWPSRMATION, CONTACT PHONE BUILDING INSPE CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 08/30/2006 Permit# CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Subtype COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks FIRE CAULK ? Phone 7602770271 Inspector Total Time CD Description 17 Interior Lath/Drywall Requested By SEAN Entered By JANEAN Act Comment Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Associated PCRs/CVs Original PCS PC040105 LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 S CRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN ST1-EI7CONCRETE STAIR SUDMI'ITAL LA COSTA GL EN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAI. LA COSTA GLEN, 2ND FLR TI @ CENT PLT , BULLETIN #5 Inspection History Date Description Act 08/23/2006 84 Rough Combo CO 08/16/2006 29 Final Plumbing AP 08/15/2006 23 Gas/Test/Repairs CO RB 08/15/2006 29 Final Plumbing CO RB 08/11/2006 23 Gas/Test/Repairs AP TP 08/11/2006 29 Final Plumbing WC TP 08/10/2006 23 Gas/Test/Repairs PA RB 08/09/2006 23 Gas/Test/Repairs NR RB 08/07/2006 17 Interior Lath/Drywall PA RB 08/03/2006 14 Frame/Steel/Boltmg/Welding AP MC 08/03/2006 17 Interior Lath/Drywall AP MC 07/27/2006 17 Interior Lath/Drywall PA RB Insp Comments RB ON T-BAR SEE NOTICE ATTACHED RB FOR GAS METER RELEASE working early (6 23am) no msp 24 HR GAS TEST STARTED 24 HR TEST NEED 24 HR TEST OK @ EXTERIOR CLOSET RMS SOFFIT FRAMING @ RM 113 & 122 HARD LID @ RM 101, 102 HALL, 112 115 AND 116 EMPLOYEES LOUNGE HARD LID OK CITY OF CARLSBAD BUILDING DEPARTMENT DATE LOCATION /??/ A- PERMIT NO NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME_ i—i FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE1? L I YES FOR FURTHER INEflBMATIQ&L CONTACT _ PHONE BUILDING IN:CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 08/23/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7602770063 Inspector Total Time Requested By PATRICK Entered By CHRISTINE CD Description Act Comment G6 CM14 Frame/Steel/Boltmg/Weldmg 24 Rough/Topout 34 Rough Electric 44 Rough/Ducts/Dampers Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL I'LANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT DEI'FERED TRUSS SUBMITIAL LA COSTA GLEN 2ND FLR Tl Q CtN I' PLT , BULLETIN #5 Date 08/16/2006 08/15/2006 08/15/2006 08/11/2006 08/11/2006 08/10/2006 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Description Act 29 Final Plumbing AP 23 Gas/Test/Repairs CO 29 Final Plumbing CO 23 Gas/Test/Repairs AP 29 Final Plumbing WC 23 Gas/Test/Repairs PA Insp RB RB RB TP TP RB Comments FOR GAS METER RELEASE working early (6 23am) no insp 24 HR GAS TEST STARTED 24 HR TEST CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION PERMIT NO FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? I I YES FOR FURTHER INFORMATION. COMTACT PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 08/16/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks/ FINAL> AM PLEASE Total Time Phone 7602770063 Inspector Requested By SEAN Entered By JANEAN CD Description 29 Final Plumbing Act Comment Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4 ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUDMITIAL LA COSTA GLEN 2ND FLR TI @ CENT PLT , BULLETIN #5 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Date Description Act 08/15/2006 23 Gas/Test/Repairs CO 08/15/2006 29 Final Plumbing CO 08/11/2006 23 Gas/Test/Repairs AP 08/11/2006 29 Final Plumbing WC 08/10/2006 23 Gas/Tesl/Repairs PA 08/09/2006 23 Gas/Test/Repairs NR 08/07/2006 17 Interior Lath/Drywall PA 08/03/2006 14 Frame/Steel/Boltmg/Welding AP 08/03/2006 17 Interior Lath/Drywall AP 07/27/2006 17 Interior Lath/Drywall PA 07/12/2006 17 Interior Lath/Drywall PA 07/10/2006 17 Interior Lath/Drywall PA Insp Comments RB working early (6 23am) no msp RB TP 24 HR GAS TEST TP RB RB RB MC MC RB PD RB STARTED 24 HR TEST NEED 24 HR TEST OK @ EXTERIOR CLOSET RMS SOFFIT FRAMING @ RM 113 & 122 HARDLID@RM 101, 102 HALL, 112, 115AND116 EMPLOYEES LOUNGE HARD LID OK FIRE CAULKING @ CEILING FOR RMS 102, 101, 115 & 116 City of Carlsbad Bldg Inspection Request For 08/09/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 00000000000 Inspector Total Time Requested By PATRICK Entered By CHRISTINE CD Description 23 Gas/Test/Repairs Act Comment M^ Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Date 08/07/2006 08/03/2006 08/03/2006 07/27/2006 07/12/2006 07/10/2006 07/10/2006 06/29/2006 06/29/2006 06/27/2006 06/27/2006 06/23/2006 Associated PCRs/CVs Original PC# PC040105 LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAL LA COSTA GLEN 2ND FLR TI @ CENT PLT BULLETIN S3 Inspection History Description 17 Interior Lath/Drywall 14 Frame/Steel/Boltmg/Welding 17 Interior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 17 Interior Lath/Drywall 84 Rough Combo 14 Frame/Steel/Bolling/Welding 17 Interior Lath/Drywall 17 Interior Lath/Drywall 22 Sewer/Water Service 17 Interior Lath/Drywall Act PA AP AP PA PA PA WC CO AP PA PA NS Insp Comments RB OK @ EXTERIOR CLOSET RMS MC SOFFIT FRAMING @RM 113 & 122 HARD LID @RM 101 102 HALL 112, 115 AND 116 EMPLOYEES LOUNGE HARD LID OK MC RB PD RB RB RB RB RB RB RB FIRE CAULKING @ CEILING FOR RMS 102 101, 115 & 116 CEILING JOISTS INSP WALLS & LID @ RM 102 & 106 SEE NOTICE ATTACHED WATER SERVICE ONLY OK NOTICECJTY OF CARLSBAD (760)602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE. LOCATION PERMIT NO /7/g? t—i FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE'' L. ! YES FOR FURTHER INFORMATION, CONTACT PHONE BUlCDlHS 11141 lUluR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 07/27/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Type COMMIND Sub Type COMM Job Address 1991 LANCEWOOD LN Suite Lot 0 Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks FIRE CAULKING Phone 7604790229 Inspector Total Time Requested By SHAWN Entered By CHRISTINE CD Description 17 Interior Lath/Drywall Comment Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Date 07/12/2006 07/10/2006 07/10/2006 06/29/2006 06/29/2006 06/27/2006 06/27/2006 06/23/2006 06/19/2006 06/19/2006 06/14/2006 06/12/2006 Associated PCRs/CVs Original PC# PC040105 LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4 ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL LA COSTA GL EN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAL LA COSTA GLCN 2ND I;LR Tl @ CENT PLT BULLETIN #5 Inspection History Description 17 Interior Lath/Drywall 17 Interior Lalh/Drywall 84 Rough Combo 14 Frame/Steel/Boltmg/Weldmg 17 Interior Lath/Drywall 17 Interior Lath/Drywall 22 Sewer/Water Service 17 Interior Lath/Drywall 17 Interior Lath/Drywall 34 Rough Electric 39 Final Electrical 14 Frame/Steel/Boltmg/Welding Act PA PA WC CO AP PA PA NS NR PA CO CO Comments FIRE CAULKING @ CEILING FOR RMS 102, 101 1154 116 Insp PD RB RB RB CEILING JOISTS INSP RB WALLS & LID @ RM 102 & 106 SEE NOTICE ATTACHED WATER SERVICE ONLY OK RB RB RB RB RB RB RB NEED CORRECTIONS FROM FRMG DONE 1ST EMR ON TESTING EQUIPMENT ONLY SEE NOTICE STILL MISSING CORRECTIONS FRM 5-1-06 City of Carlsbad Bldg Inspection Request For 06/29/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MA1NT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Subtype COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks fire caulk Phone 9016017140 Inspector Total Time CD Description 17 Interior Lath/Drywall fi ~Comment Requested By DAN Entered By CHRISTINE t l;ol®r^ /**•£• Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRA!, PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COST A GLEN BULLETIN -I ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE , STAIR SUBMITTAL LA COST A GLEN CENTRAL PLANT DEFFERED TRUSS SUBMITIAI. LA COSTA GLEN 2ND FLRT1 @ CENT PLT BULLETINS ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Date Description 06/27/2006 17 Interior Lath/Drywall 06/27/2006 22 Sewer/Water Service 06/23/2006 17 Interior Lath/Drywall 06/19/2006 17 Interior Lath/Drywall 06/19/2006 34 Rough Electric 06/14/2006 39 Final Electncal 06/12/2006 14 Frame/Steel/Bolting/Welding 06/12/2006 17 Interior Lath/Drywall 06/12/2006 18 Exterior Lath/DrywaJI 06/12/2006 39 Final Electrical 06/08/2006 17 Interior Lath/Drywall 06/08/2006 84 Rough Combo Act PA PA NS NR PA CO CO CO AP we CO CO Insp RB RB RB RB RB RB RB RB RB RB RB RB Comments SEE NOTICE ATTACHED WATER SERVICE ONLY OK NEED CORRECTIONS FROM FRMG DONE 1ST EMR ON TESTING EQUIPMENT ONLY SEE NOTICE STILL MISSING CORRECTIONS FRM 5-1-06 SEE NOTICE ATTACHED COMPLETED WITHOUT INSP NEEDCORR FROM 5-1-& 5-12 CITY OF CARLSBAD BUILDING DEPARTMENT DATE NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME LOCATION /? f //f <• fl PERMIT NO FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE1? i__i YES FOR FURTHER INFORMATION, CONTACT PHONE CODE ENFORCEMf NT OFFICER City of Carlsbad BIdg Inspection Request For 06/27/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MA1NT & STORAGE Inspector Assignment RB Subtype COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 9016017140 Inspector Total Time Requested By DON Entered By CHRISTINE CD Description 17 Interior Lath/Drywall 22 Sewer/Water Servicu t Comment Pft Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Date 06/23/2006 06/19/2006 06/19/2006 06/14/2006 06/12/2006 06/12/2006 06/12/2006 06/12/2006 06/08/2006 06/08/2006 06/01/2006 Associated PCRs/CVs Original PC# PC040105 LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN TWO LA COSTA GLKN CENTRAL PLANT REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL LA COSTA GLFN CENTRAL PLANT DEFFERED TRUSS SUBMITIAL LA COSTA GLEN 2ND FLR Tl % CEN1 PLT , BULLETIN #5 Inspection History Description Act 17 Interior Lath/Drywall NS 17 Interior Lath/Drywall NR 34 Rough Electric PA 39 Final Electrical CO 14 Frame/Steel/Bolting/Weldmg CO RB 17 Interior Lath/Drywall CO RB 18 Exterior Lath/Drywall AP RB 39 Final Electrical WC RB 17 Interior LalWDrywall CO RB COMPLETED WITHOUT INSP 84 Rough Combo CO RB NEED CORR FROM 5-1-& 5-12 24 Rough/Topout AP RB COMPLETED Insp Comments RB RB NEED CORRECTIONS FROM FRMG DONE 1ST RB EMR ON TELSTING EQUIPMENT ONLY RB SEE NOTICE STILL MISSING CORRECTIONS FRM 5-1-06 SEE NOTICE ATTACHED NOTICE CITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE fa - 2- ~? -~ $& TIME_ LOCATION. PERMIT NO ,\ -^—'- 1 J ) A, 2. FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? i_J YES FOR FURTHER INFORMATION, CONTACT PHONE CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 06/19/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks/ftM PLEASE Phone 9016017140 Inspector Total Time Requested By DON Entered By CHRISTINE CD Description 17 Interior Lath/Dry wall t 34 Rough Electric Act Comment Pfl Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Date 06/14/2006 06/12/2006 06/12/2006 06/12/2006 06/12/2006 06/08/2006 06/08/2006 06/01/2006 05/05/2006 05/01/2006 05/01/2006 Associated PCRs/CVs Original PC# PC040105 LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE , STAIR SL'BMITTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAL LA COSTA GLEN, 2ND FLR Tl @ CENT PLT , BULLETIN X5 Inspection History Description 39 Final Electrical 14 Frame/Steel/Bolting/Welding 17 Interior Lath/Drywall 18 Exterior Lath/Drywall 39 Final Electrical 17 Interior Lath/Drywall 84 Rough Combo 24 Rough/Topoul 84 Rough Combo 14 Frame/Steel/Bolting/Weldmg 24 Rough/Topout Act CO CO CO AP WC CO CO AP AP CO CO Insp RB RB RB RB RB RB RB RB PD RB RB Comments SEE NOTICE STILL MISSING CORRECTIONS FRM 5-1-06 SEE NOTICE ATTACHED COMPLETED WITHOUT INSP NEEDCORR FROM 5-1-& 5-12 COMPLETED MAINT BLDG SEE NOTICE ATTACHED UNSCHEDULED BUILDING INSPECTION DATE (p ( /*? ' O & INSPECTOR /V /> PERMIT # CrU^^V<' r PLAN CHECK # JOB ADDRESS DESCRIPTION CODE DESCRIPTION ACT COMMENTS NOTICE CITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE ~f£-0 £ ;._, PATE if IT^CS K> TIME. LOCATION^ PERMIT NO ._ ^ ^' ' S FOR INSPECTION CALL (760) 602-2725 RE-INSPECTtON FEE DUE'7 L_J YES FOR FURTHER (NFORMATION, CONTACT PHONE BUILDING ^PBCTCSJ.^*^ CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 06/12/2006 Permit# CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT.OFFICE.LAUNDRY.MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7602770047 Inspector Total Time CD Description 17 Interior Lath/Drywall 39 Final Electrical Requested By JAKE Entered By JANEAN Comment Uses Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED Associated PCRs/CVs Original PC# PC040105 LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE , STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAL LA COSTA GLEN, 2ND FLR TI @ CENT PLT , BULLETIN #5 Inspection History Date Description Act Insp 06/08/2006 17 Interior Lath/Drywall CO RB 06/08/2006 84 Rough Combo CO RB 24 Rough/Topout AP RB 84 Rough Combo 14 Frame/Steel/Bolting/Welding 24 Rough/Topout 34 Rough Electric 24 Rough/Topout 84 Rough Combo 06/01/2006 05/05/2006 05/01/2006 05/01/2006 05/01/2006 04/26/2006 04/13/2006 04/11/2006 04/11/2006 15 Roof/Reroof 23 Gas/Test/Repairs Act CO CO AP AP CO CO CO NR CA AP AP PD RB RB RB RB PD PD PD Comments COMPLETED WITHOUT INSP NEED CORR FROM 5-1- & 5-12 COMPLETED MAINT BLDG SEE NOTICE ATTACHED MISSING TOP OUT TEST GAS IN PLANT CITY OF CARLSBAD BUILDING DEPARTMENT DATE i> NOTICE LOCATION /??/ PERMIT NO (760) 602-2700 1 635 FARADAY AVENUE TIME FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? I I YES FOR FURTHER INFORMATION, CONTACT . PHONE CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 06/08/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7604790216 Inspector Total Time Requested By NA Entered By JANEAN CD Description 17 Interior Lath/Drywall Act Comment Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 PCR06072 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLtN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLFN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLtN STEHL/CONCRETE STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBM1TIAL LA COSTA GLFN, 2ND FLR TI @ CENT PLT , BULLETIN #5 Date 06/01/2006 05/05/2006 05/01/2006 05/01/2006 05/01/2006 04/26/2006 04/13/2006 04/11/2006 04/11/2006 03/02/2006 02/24/2006 02/24/2006 ISSUED ISSUED ISSUED ISSUED ISSUED PENDING Inspection History Description 24 Rough/T 84 Rough C 14 Frame/S 24 Rough/T 34 Rough E 24 Rough/T 84 RoughC 15 Roof/Reroof 23 Gas/Test/Re 15 Roof/Reroof 61 Footing opout ombo leel/Bolting/Welc opout lectnc opout ombo oof L/Repairs oof id Beam Act AP AP img CO CO CO NR CA AP AP PA AP we Insp RB PD RB RB RB RB PD PD PD RB TP TP Comments COMPLETED MAINT BLDG SEE NOTICE ATTACHED MISSING TOP OUT TEST GAS IN PLANT SHEATING & TRUSS OK @ MECHANICAL BLDG RETAINING & SCREEN WALLS WALL L L NOTICE CITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE (P ^ 0^^ (S US? TIME_ LOCATION ., PERMIT NO „ ,. -4$3£ L^^-u*?**^--jL^. +t*jr^ fi*S*>4 ~ Zj^^^gx^-L '—! FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE'' ! I YES FOR FURTHER INFORMATION-CONTACT PHONE BUILDING INSPECTOR CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 05/01/2006 Permit# CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT.OFFICE.LAUNDRY.MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location OWNER CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7606070063 Inspector Total Time CD Requested By JAKE Entered By JANEAN Description Frame/Steel/Bolting/Welding Comment Comments/Notices/Hold Associated PCRs/CVs Original PC# PC040105 PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA GLDN STEEL/CONCKETH , STAIR SUBMITTAL PCR06008 ISSUED LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBMITIAL Inspection History Date Description Act 04/26/2006 24 Rough/Topout NR 04/13/2006 84 Rough Combo CA 04/11/2006 15 Roof/Reroof AP 04/11/2006 23 Gas/Test/Repairs AP 03/02/2006 15 Roof/Reroof PA 02/24/2006 61 Footing AP 02/24/2006 62 Steel/Bond Beam WC 02/21/2006 15 Roof/Reroof CO 02/17/2006 15 Roof/Reroof NS 02/09/2006 63 Walls AP 02/02/2006 63 Walls WC 02/02/2006 66 Grout AP 02/01/2006 63 Walls WC Comments MISSING TOP OUT TEST Insp RB PD PD PD GAS IN PLANT RB SHEATING & TRUSS OK @ MECHANICAL BLDG RETAINING & SCREEN WALLS WALL L LTP TP RB RB PD RB RB RB ON ROOF NAILING ftgs FOR TOP LIFT CITY OF CARLSBAD BUILDING DEPARTMENT DATE LOCATION PERMIT NOTICE (760) 602-2700 1635 FARADAY AVENUE &—IA FOR INSPECTION CALL (760) $02-2725 RE-INSPECTION FEE DUE? FOR FURTHEfiiNFORM&TION, CONTACT __ YES PHONE City of Carlsbad Bldg Inspection Request For 04/26/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7602770047 Inspector Total Time Requested By JAKE Entered By JANEAN CD Description 24 Rough/Topout Act ment Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEI./CONCRETE STAIR SLJBMITTAL LA COSTA Gl EN CENTRAL PLANT ORFFERED TRUSS SUBMITIAL ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Date Description 04/13/2006 84 Rough Combo 04/11/2006 15 Roof/Reroof 04/11/2006 23 Gas/Test/Repairs 03/02/2006 15 Roof/Reroof 02/24/2006 61 Footing 02/24/2006 62 Steel/Bond Beam 02/21/2006 15 Roof/Reroof 02/17/2006 15 Roof/Reroof 02/09/2006 63 Walls 02/02/2006 63 Walls 02/02/2006 66 Grout 02/01/2006 63 Walls 02/01/2006 66 Grout Act CA AP AP PA AP we CO NS AP we AP we CO Insp PD PD PD RB TP TP RB RB PD RB RB RB RB Comments GAS IN PLANT SHEATING & TRUS SCREEN WALLS WALL L L ON ROOF NAILING ftgs FOR TOP LIFT TOP LIF1 CITY OF CARLSBAD BUILDING DEPARTMENT NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME.. LOCATION PERMIT NO •4^ FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE'' Lj YES FOR FURTHER INFORMATION, CQfJTACT BUILDING INBPECTOFT PHONE CODE LNFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 02/24/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7602778806 Inspector Total Time Requested By TONY Entered By JANEAN CD Description 62 Steel/Bond Beam Act Comment AM if Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS I.A COSTA GLEN STEEL/CONCRETE , STAIR SUBM1TTAL LA COSTA GLEN CENTRAL PLANT, DEFFERED TRUSS SUBMIT1AL ISSUED ISSUED ISSUED ISSUED ISSUED Inspection History Date Description Act Insp 02/21/2006 15 Roof/Reroof CO RB 02/17/2006 15 Roof/Reroof NS RB 02/09/2006 63 Walls AP PD 02/02/2006 63 Walls WC RB 02/02/2006 66 Grout AP RB 02/01/2006 63 Walls WC RB 02/01/2006 66 Grout CO RB 01/24/2006 12 Steel/Bond Beam 'PA RB 01/18/2006 66 Grout AP RB 01/09/2006 66 Grout AP PY 01/06/2006 11 Ftg/Foundation/Piers AP RB 01/05/2006 11 Ftg/Foundation/Piers CO RB 01/04/2006 66 Grout PA RB Comments ON ROOF NAILING FOR TOP LIFT TOP LIFT 4TH LIFT @ CENTRAL PLANT OK ON 3RD FLOOR LIFT SCREEN WALL pad for soft water tanks FOR TANK PAD - NEED SPEC INSP REPORT 2ND LIFT MAINTANCE BLDG City of Carlsbad Bldg Inspection Request For 02/02/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT.OFFICE.LAUNDRY.MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks CMU WALL INSPECTION Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 63 Walls Act Comment ..__ fi-f f?<- - Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 PCR06008 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CFNTRAL PLANT REVISIONS-BULLETIN TWO LA COSTA GLCN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4 ARCH REVISIONS f,A COSTA GLEN STCHL/CONCRETE STAIR SUBMITTAL LA COSTA GLEN CENTRAL PLANT DEFFEREO TRUSS SUBMITIAL ISSUED ISSUED ISSUED ISSUED PENDING Inspection History Date Description Act 01/24/2006 12 Steel/Bond Beam PA 01/18/2006 66 Grout AP 01/09/2006 66 Grout AP 01/06/2006 11 Ftg/Foundation/Piers AP 01/05/2006 11 Ftg/Foundation/Piers CO 01/04/2006 66 Grout PA 01/04/2006 66 Grout PA 12/22/2005 62 Steel/Bond Beam AP 12/22/2005 66 Grout AP 12/21/2005 11 Ftg/Foundation/Piers WC 12/21/2005 12 Steel/Bond Beam PA 12/21/2005 65 Retaining Walls WC 12/13/2005 11 Ftg/Foundation/Pters CO Insp Comments RB 4TH LIFT @ CENTRAL PLANT OK RB ON 3RD FLOOR LIFT PY SCREEN WALL RB pad for soft water tanks RB FOR TANK PAD-NEED SPEC INSP REPORT RB 2ND LIFT MAINTANCE BLDG RB 3RD LIFT ©COOLING TOWER PS NOTED ON PLANS PS 2ND LIFT OK W/0 CITY INSP PLANS RB RB SEE JOB PLANS RB PS MISSING STEEL COOLING TOWER NOTED ON City of Carlsbad Bldg Inspection Request For 01/24/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks CMU STEEL Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 12 Steel/Bond Beam Act Commen/ f/i Comments/Notices/Hold Associated PCRs/CVs Original PCS PC040105 PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED I.A COSTA GI.EN BULLETIN 4 ARCH REVISIONS PCR05223 ISSUED LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL PCR06008 PENDING LA COSTA GLEN CENTRAL PLANT DEFFERED TRUSS SUBMITIAL Date 01/18/2006 01/09/2006 01/06/2006 01/05/2006 01/04/2006 01/04/2006 12/22/2005 12/22/2005 12/21/2005 12/21/2005 12/21/2005 12/13/2005 12/12/2005 Inspection History Description 66 Grout 66 Grout 11 Ftg/Fou 11 Ftg/Fou, 66 Grout 66 Grout 62 Steel/Be 66 Grout 66 Grout idation/Piers idation/Piers no1 Beam idation/Piers nd Beam 3 Walls idation/Piers Act AP AP AP CO PA PA AP AP we PA we CO AP Insp RB PY RB RB RB RB PS PS RB RB RB PS PS Comments ON 3RD FLOOR LI FT SCREEN WALL pad for soft water tanks FOR TANK PAD - NEED SPEC INSP REPORT 2ND LIFT MAINTANCE BLDG 3RD LIFT @ COOLING TOWER NOTED ON PLANS 2ND LIFT OK W/O CITY INSP @ COOLING TOWER NOTED ON PLANS SEE JOB PLANS MISSING STEEL noted on plans City of Carlsbad Bldg Inspection Request For 01/18/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Type COMMIND Sub Type COMM Job Address 1991 LANGEWOOD LN Suite Lot 0 Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks emu wall grout Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description Act Comment Comments/Notices/Hold PCR05141 PCR05143 PCR05154 PCR05217 PCR05223 Associated PCRs/CVs Original PC# PC040105 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COS FA GLI-N CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COS TAGLFN CENTRAL PLANT BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLLN DULLLTIN 4, ARCH REVISIONS LA COSTA GUN SThtL/CONCRETE STAIR SUDMITTAL ISSUED ISSUED ISSUED ISSUED Inspection History Date Description Act 01/09/2006 66 Grout AP 01/06/2006 11 Ftg/Foundation/Piers AP 01/05/2006 11 Ftg/Foundation/Piers CO 01/04/2006 66 Grout PA 01/04/2006 66 Grout PA 12/22/2005 62 Steel/Bond Beam AP 12/22/2005 66 Grout AP 12/21/2005 11 Ftg/Foundation/Piers WC 12/21/2005 12 Steel/Bond Beam PA 12/21/2005 65 Retaining Walls WC 12/13/2005 11 Ftg/Foundation/Piers CO 12/12/2005 66 Grout AP 12/06/2005 11 Ftg/Foundation/Piers AP 12/06/2005 12 Steel/Bond Beam AP Insp Comments PY SCREEN WALL RB pad for soft water tanks RB FOR TANK PAD • NEED SPEC INSP REPORT RB 2ND LIFT MAINTANCE BLDG RB 3RD LIFT @ COOLING TOWER PS NOTED ON PLANS PS 2ND LIFT OK W/0 CITY INSP @ COOLING TOWER NOTED ON PLANS RB RB RB PS PS PS PS SEE JOB PLANS MISSING STEEL noted on plans HILITED ON PLANS YELLOW 2ND LIFT HILITED YELLOW City of Carlsbad Bldg Inspection Request For 01/06/2006 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment RB Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES ULC Owner Remarks Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 11 Ftg/Foundation/Piers Act Comment Comments/Notices/Hold Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL Inspection History Date Description 01/04/2006 66 Grout 01/04/2006 12/22/2005 12/22/2005 66 Grout 62 Sleet/Bond Beam 66 Grout 12/21/2005 12/21/2005 12/21/2005 12/13/2005 12/12/2005 12/06/2005 12/06/2005 12/05/2005 12/05/2005 11/30/2005 11 Ftg/Foundalion/Piers 12 Steel/Bond Beam 65 Retaining Walls 11 Ftg/Foundation/Piers 66 Grout 11 Ftg/Foundation/Piers 12 Steel/Bond Beam 11 Ftg/Foundation/Piers 66 Grout 62 Steel/Bond Beam Act PA PA AP AP we PA we CO AP AP AP CO NR AP Insp RB RB PS PS RB RB RB PS PS PS PS PS PS PS Comments 2ND LIFT MAINTANCE BLDG 3RD LIFT @ COOLING TOWER NOTED ON PLANS 2ND LIFT OK W/0 CITY INSP @ COOLING TOWER NOTED ON PLANS SEE JOB PLANS MISSING STEEL noted on plans HILITED ON PLANS YELLOW 2ND LIFT HILITED YELLOW HILITED PINK City of Carlsbad Bldg Inspection Req For 01/04/2006 Inspector AssignmPermit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks CMU WALL GROUT Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 66 Grout Act Comment Comments/Notices/Hold Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRA1 PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA GLEN STEEL/CONCRETF STAIR SUBMITTAL Inspection History Date Description Act Insp 12/22/2005 62 Steel/Bond Beam AP PS 12/22/2005 66 Grout AP PS 12/21/2005 11 Ftg/Foundation/Piers WC RB 12/21/2005 12 Steel/Bond Beam PA RB 12/21/2005 65 Retaining Walls WC RB 12/13/2005 11 Ftg/Foundation/Piers CO PS 12/12/2005 66 Grout AP PS 12/06/2005 11 Ftg/Foundation/Piers AP PS 12/06/2005 12 Steel/Bond Beam AP PS 12/05/2005 11 Ftg/Foundation/Piers CO PS 12/05/2005 66 Grout NR PS 11/30/2005 62 Steel/Bond Beam AP PS 11/23/2005 11 Fig/Foundation/Piers CO JM 11/23/2005 13 Shear Panels/HD's NR JM Comments NOTED ON PUNS 2ND LIFT OK W/O CITY INSP @ COOLING TOWER NOTED ON PLANS SEE JOB PLANS MISSING STEEL noted on plans HILITED ON PLANS YELLOW 2ND LIFT HILITED YELLOW HILITED PINK PAD FTGS NOT PER PLAN - NEED SOILS LETTER City of Carlsbad Bldg Inspection Request For 12/22/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS Type COMMIND Sub Type COMM Job Address 1991 LANCEWOOD LN Suite Lot 0 Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks WATER PROOF, FRENCH DRAJN,OK TO CRT Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 62 Steel/Bond Beam 66 Grout Act ^ Comment Com ments/Notices/Hold n^ Date 12/13/2005 12/12/2005 12/06/2005 12/06/2005 12/05/2005 12/05/2005 11/30/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA GLEN STEEL/CONCRETE , STAIR SUBMITTAL Inspection History Description 11 Ftg/Foundation/Piers 66 Grout 11 Ftg/Foundation/Piers 12 Steel/Bond Beam 11 Ftg/Foundation/Piers 66 Grout 62 Steel/Bond Beam 11 Ftg/Foundation/Piers 13 Shear Panels/HD's 14 Frame/Steel/Bolting/Weldmg 15 Roof/Reroof 24 Rough/Topout 34 Rough Electric Act CO AP AP AP CO NR AP CO NR NR NR NR NR Insp Comments PS MISSING STEEL noted on plans HILITED ON PLANS YELLOW 2ND LIFT HILITED YELLOW PS PS PS PS PS PS JM JM JM JM JM JM HILITED PINK PAD FTGS NOT PER PLAN - NEED SOILS LETTER NOTICECITY OF CARLSBAD (760) 602-2700 BUILDING DEPARTMENT 1635 FARADAY AVENUE DATE LOCATION PERMIT NO A/Q FOR INSPECTION CALL (760) 602-2725 RE-INSPECTION FEE DUE? ! I YES NATION, CONTACT _^__ CODE ENFORCEMENT OFFICER City of Carlsbad Bldg Inspection Request For 12/12/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks emu wall grout Phone 7602778806 Inspector Total Time Requested By TONY Entered By JANEAN CD Description 66 Grout Comment Comments/Notices/Hold Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 ISSUED LA COSTA GLEN STEEL/CONCRETE , STAIR SUBMITTAL Inspection History Date 12/06/2005 12/06/2005 12/05/2005 12/05/2005 11/30/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/21/2005 11/21/2005 11/15/2005 Description 11 12 11 66 62 11 13 14 15 24 34 44 11 61 66 Ftg/Foundatio n/P IBFS Steel/Bond Beam Ftg/Foundation/Piers Grout Steel/Bond Beam Ftg/Foundation/Piers Shear Panels/HD's Frame/Steel/Bolting/Welding Roof/Reroof Rough/Topout Rough Electric Rough/Ducts/Dampers Ftg/Foundation/Piers Footing Grout Act AP AP CO NR AP CO NR NR NR NR NR NR we AP CO Insp PS PS PS PS PS JM JM JM JM JM JM JM TP TP PS Comments HILITED ON PLANS YELLOW 2ND LIFT HILITED YELLOW HILITED PINK PAD FTGS NOT PER PLAN - NEED SOILS LETTER 1ST LIFT CMU WALL AT CENTRAL PLANT WRONG DETAIL City of Carlsbad Bldg Inspection Request For 12/06/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7602778806 Inspector / Total Time Requested By TONY Entered By CHRISTINE CD Description 11 Ftg/Foundation/Piers 12 Steel/Bond Beam Act Comment Comments/Notices/Hold Associated PCRs/CVs PCR05141 ISSUED PCR05143 ISSUED PCR05154 ISSUED PCR05217 ISSUED PCR05223 PENDING Inspection History Dale Description 12/05/2005 11 Ftg/Foundation/Piers 12/05/2005 66 Grout 11/30/2005 62 Steel/Bond Beam 11/23/2005 11 Rg/Foundation/Piers 11/23/2005 13 Shear Panels/HD's 11/23/2005 14 Frame/Steel/Bolting/Welding 11/23/2005 15 Roof/Reroof 11/23/2005 24 Rough/Topout 11/23/2005 34 Rough Electric 11/23/2005 44 Rough/Ducts/Dampers 11/21/2005 11 Ftg/Foundation/Piers 11/21/2005 61 Footing 11/15/2005 66 Grout LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL Comments HILITED PINK PAD FTGS NOT PER PLAN - NEED SOILS LETTER Act CO NR AP CO NR NR NR NR NR NR we AP CO Insp PS PS PS M M JM JM JM JM JM TP TP PS 1ST LIFT CMU WALL AT CENTRAL PLANT WRONG DETAIL City of Carlsbad Bldg Inspection Request For 12/05/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS Type COMMIND Sub Type COMM Job Address 1991 LANCEWOOD LN Suite Lot 0 Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks CMU wall grout and P T. Cable Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 11 Ftg/Foundation/Piers 66 Grout t Comment Comments/Notices/Hold Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE PCR05154 ISSUED I.A COSTA GLEN CENTRAL PLANT, BULLETIN H STRUCT AND PLUMBING PCR05217 ISSUED LA COSTA GLEN BULLETIN 4, ARCH REVISIONS PCR05223 PENDING LA COSTA GLEN STEEL/CONCRETE STAIR SUBMITTAL Inspection History Date Description Act 11/30/2005 62 Steel/Bond Beam AP 11/23/2005 11 Ftg/Foundation/Piers CO 11/23/2005 13 Shear Panels/HD's NR 11/23/2005 14 Frame/Steel/Boltmg/Welding NR 11/23/2005 15 Roof/Reroof NR 11/23/2005 24 Rough/Topout NR 11/23/2005 34 Rough Electric NR 11/23/2005 44 Rough/Ducts/Dampers NR 11/21/2005 11 Ftg/Foundation/Piers WC 11/21/2005 61 Footing AP 11/15/2005 66 Grout CO 11/08/2005 81 Underground Combo AP 10/28/2005 11 Ftg/Foundation/Piers CO Insp Comments PS HILITED PINK JM PAD FTGS NOT PER PLAN - NEED SOILS LETTER JM JM JM JM JM JM TP TP 1ST LIFT CMU WALL AT CENTRAL PLANT PS WRONG DETAIL PS NEED SI REPORT FOR 5IN SLAB PC COOLING TOWER PADS SEE SPEC INSP REPORT POURED City of Carlsbad Bldg Inspection Request For 11/30/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS 1991 LANCEWOODLN Lot 0 Type COMMIND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks CMUWALL Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 62 Steel/Bond Beam AcL Comment Comments/Notices/Hold Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRAL. PLANT, REVISIONS-BULLETIN TSVO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT BULLETINS STRUCT AND PLUMBING PCR05217 PENDING LA COSTA GLEN BULLETIN 4, ARCH REVISIONS Date 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/23/2005 11/21/2005 11/21/2005 11/15/2005 1 1/08/2005 10/28/2005 10/27/2005 10/25/2005 Inspection History Description 11 13 14 15 24 34 44 11 61 66 81 11 12 11 Ftg/Foundation/Piers Shear Panels/HD's Frame/Steel/BoltingA'Velding Roof/Reroof Rough/Topout Rough Electric Rough/Ducts/Dampers Ftg/Foundaton/Piers Footing Grout Underground Combo Ftg/Foundation/Piers Steel/Bond Beam Ftg/Foundation/Piers Act CO NR NR NR NR NR NR we AP CO AP CO PA CO Insp JM JM JM JM JM JM JM TP TP PS PS PC PC PS Comments PAD FTGS NOT PER PLAN - NEED SOILS LETTER 1ST LIFT CMU WALL AT CENTRAL PLANT WRONG DETAIL NEED SI REPORT FOR SIN SLAB COOLING TOWER PADS SEE SPEC INSP REPORT BEFORE MY APPROVAL PERIMETER FTG & PIERS - SEE HIGH LITED PLAN PLANT MISSING SLAB DOWELS POURED @ CENTRAL City of Carlsbad Bldg Inspection Request For 11/08/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks p t. cable inspection Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 11 Ftg/Foundation/Piers Comment PCR05141 PCR05143 PCR05154 Date Description 10/28/2005 11 Ftg/Foundation/Piers 10/27/2005 12 Steel/Bond Beam Associated PCRs/CVs ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN TWO ISSUED LA COSTA GLEN CENTRAL PLANT, REVISIONS-BULLETIN ONE ISSUED LA COSTA GLEN CENTRAL PLANT, BULLETIN #3 STRUCT AND PLUMBING Inspection History Act Insp Comments CO PC COOLING TOWER PADS SEE SPEC INSP REPORT POURED BEFORE MY APPROVAL PA PC PERIMETER FTG & PIERS - SEE HIGH LITED PLAN @ CENTRAL PLANT MISSING SLAB DOWELS10/25/2005 11 Fig/Foundation/Piers CO PS 10/25/2005 12 Steel/Bond Beam CO PS 09/27/2005 11 Ftg/Foundahon/Piers AP PS 09/16/2005 41 Underground Duels AP PS 09/14/2005 22 Sewer/Water Service AP PS 09/14/2005 31 Underground/Conduit-Wiring AP PS 09/12/2005 22 Sewer/Water Service CO PS 09/09/2005 22 Sewer/Water Service CO PS 09/07/2005 22 Sewer/Water Service PA PS 08/15/2005 21 Underground/Under Floor AP PS 08/09/2005 31 Underground/Conduit-Wiring AP PS 08/02/2005 31 Underground/Conduit-Wiring AP PS 08/01/2005 21 Underground/Under Floor PA PS 08/01/2005 41 Underground Ducts PA PS 07/25/2005 21 Underground/Under Floor AP PS 07/25/2005 22 Sewer/Water Service AP PS ELEV PIT FLR & WALLS OVER PHONE STORNM DRAIN SAME AS 9/9/05 NO FALL MISSING CO NOT SHADED STORM DRAIN YELLOW HILITE YELLOW HILITED ORANGE HILITE YELLOW HI LITE YELLOW HYDRO City of Carlsbad Bldg Inspection Request For 10/28/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS 1991 LANCE WOOD LN Lot 0 Type COMM1ND Sub Type COMM Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 11 Ftg/Foundation/Piers Act Comment C PCR05141 PCR05143 PCR05154 Date 10/27/2005 10/25/2005 10/25/2005 09/27/2005 09/16/2005 09/14/2005 09/14/2005 09/12/2005 09/09/2005 09/07/2005 08/15/2005 08/09/2005 08/02/2005 08/01/2005 08/01/2005 07/25/2005 07/25/2005 Associated PCRs/CVs ISSUED LA COSTA ULEN CENTRAL PLANT, REVISIONS-BULLETIN TWO ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS -BULLETIN ONE ISSUED LA COSTA GLEN CENTRAL PLANT. BULLETINS STRUCT'AND PLUMBING Inspection History Act Insp Comments PA PC PERIMETER FTG & PIERS SEE HIGH LITED PLAN @ CENTRAL Description 12 Steel/Bond Beam 11 Ftg/Foundation/Piers CO PS 12 Steel/Bond Beam CO PS 11 Ftg/Foundation/Piers AP PS 41 Underground Ducts AP PS 22 Sewer/Water Service AP PS 31 Underground/Conduit-Wiring AP PS 22 Sewer/Water Service CO PS 22 Sewer/Water Service CO PS 22 Sewer/Watei Service PA PS 21 Underground/Under Floor AP PS 31 Underground/Conduit-Wiring AP PS 31 Underground/Conduit-Winng AP PS 21 Underground/Under Floor PA PS 41 Underground Ducts PA PS 21 Underground/Under Floor AP PS 22 Sewer/Water Service AP PS PLANT MISSING SLAB DOWELS ELEV PIT FLR & WALLS OVER PHONE STORNM DRAIN SAME AS 9/9/05 NO FALL MISSING C O NOT SHADED STORM DRAIN YELLOW HILITE YELLOW HILITED ORANGE HILITE YELLOW HILITE YELLOW HYDRO City of Carlsbad Bldg Inspection Request For 09/27/2005 Permit* CB044304 Title LA COSTA GLEN-7523 SF MECHANIC Description CENTRAL PLANT,OFFICE,LAUNDRY,MAINT & STORAGE Inspector Assignment PS Sub Type COMM 1991 LANCEWOODLN Lot 0 Type COMMIND Job Address Suite Location APPLICANT CONTINUING LIFE COMMUNITIES LLC Owner Remarks REBAR FOR ELEV PIT Phone 7602778806 Inspector Total Time Requested By TONY Entered By CHRISTINE CD Description 11 Ftg/Foundation/Piers Act Comment Associated PCRs/CVs PCR05141 ISSUED LA COSTA GLEN CENTRAL PLANT, REVIS1ONS--BULLEFIN TWO PCR05143 ISSUED LA COSTA GLEN CENTRAL PLANT REVISIONS-BULLETIN ONE PCR05154 ISSUED LA COSTA GLEN CENTRAL PLANT BULLETFN#3 STRUCT AND PLUMBING Inspection History Comments OVER PHONE STORNM DRAIN SAME AS 9/9/05 NO FALL MISSING C O NOT SHADED STORM DRAIN YELLOW HILITE YELLOW HILITED ORANGE HILITE YELLOW HILITE YELLOW HYDRO Date 09/16/2005 09/14/2005 09/14/2005 09/12/2005 09/09/2005 09/07/2005 08/15/2005 08/09/2005 08/02/2005 08/01/2005 08/01/2005 07/25/2005 07/25/2005 Description 41 22 31 22 22 22 21 31 31 21 41 21 22 Underground Ducts Sewer/Water Service Underground/Conduit-Wiring Sewer/Water Service Sewer/Water Service Sewer/Water Service Underground/Under Floor Underground/Conduit-Wiring Underground/Conduit-Wiring Underground/Under Floor Underground Ducts Underground/Under Floor Sewer/Water Service Act AP AP AP CO CO PA AP AP AP PA PA AP AP Insp PS PS PS PS PS PS PS PS PS PS PS PS PS L CONTINUING LIFE COMMUNITIES November 3, 2006 Pete Dreibelbis Building Inspector City of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Reference La Costa Glen Building D (Hillside Building) Subject Levante Street West Sidewalk Dear Mr Dreibelbis As a follow up to our onsite meeting of October 24, 2006, to find a potential workable solution, to fix the five year old previously approved sidewalk adjacent to a portion of Levante Street, with the City of Carlsbad's concurrence, CLC is prepared to offer the following corrections to the West Levante sidewalk 1 At the top (South) of West Levante and the intersection of Silverleaf Circle, CLC will agree to remove the "non conforming" ramped area that leads to the pedestrian cross walk to the Commons Building and install a similar ramp in this area but one that substantially conforms to the City allowable slopes and cross slopes Please see Area "A" designated on the attached area site plan 2 Continuing Life Communities (CLC) agrees to remove and replace the center section of four foot wide sidewalk that exceeds a two percent cross slope with a five foot wide sidewalk that does not exceed two percent cross slope Please see Area "B" designated on the attached area site plan 3 At the bottom (North) of West Levante and the intersection of Rush Rose Drive CLC will agree to remove the "non conforming" ramped area that leads to the pedestrian cross walk to the North Entry Gate area and install a similar ramp in this area but one that substantially conforms to the City allowable slopes and cross slopes Please see Area "C" designated on the attached area site plan Mr Dreibelbis, if you are in agreement with the proposed design solution as outlined above, please indicate your agreement by signing the letter below where designated and returning to me at the CLC office If you have questions, I can be reached at 760-704- 6252 1940 Levante Street - Carlsbad, CA 92009 TEL 760-704-6300 ~ FAX 760-704-6262 wwwcontmuinglife com I arruJi agreement with the abaue outlined design Gary E Kutz Vice President - Independent Living Development Mr Pete Dreilbelbis, Building Inspector Thank you in advance for your attention to this matter Sincerely, Date Attachment CONTINUING LIFE COMMUNITIES September 19,2006 Pete Dreilbelbis Building Inspector City Of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Re Building D (Hillside Building) Dear Mr Dreilbelbis Based on the today's review of the project, and subsequent discussions, we would like to take this opportunity to project the time frames for completion of the following items that have been identified by the City of Carlsbad inspection department I Life Safety Items - (1) smoke seal w/astragals at double egress doors, (2) all fire sating, (3) installation of an additional handrail (with removable section for access to HVAC closet) and modification of the existing handrail (12" extension past the end of the ramp), and (4) City approval of the modification to the shafts (change from vertical to horizontal fire dampers) in area 1/level 1 All of the above items are to be completed and inspected by late Wednesday, September 20, 2006 II All Other Items (with the exception of remaining attic ventilation) - to be completed and inspected by October 10, 2006 These items include sidewalk replacement adjacent to Levante Street and east of the permitted building Demolition of this sidewalk will commence immediately upon completion of a civil engineering survey and plan and upon review/approval of same by City Inspector Ron Burke (residents will be protected from walkway during its re- construction) Please note that two other walkways exist for the building residents to reasonably access the southern portion of the community III Attic Ventilation - due to the projected time frames of 4-6 weeks for fabrication/delivery and 1-2 weeks for installation, attic ventilation to be completed and inspected by November 15, 2006 To date we have received Building D fire and engineering signoffs and have been told that we will receive planning signoff tomorrow upon completion of a small guard rail We expect to be in position to receive building signoff late tomorrow (after completion of the above life safety items) thanks in part to the City's efforts on our behalf to help make this possible Thank you for your help and understanding Sincerely, Continuing Life Communities E jkistmJWilson III Chief-Operating Officer 1940 Levante Street - Carlsbad, CA 92009 TEL 760-704-6300 ~ FAX 760 704-6262 wwwcontmuinghfe com CONTINUING LIFE COMMUNITIES November 3, 2006 Pete Dreibelbis Building Inspector City of Carlsbad 1635 Faraday Avenue Carlsbad, California 92008 Reference La Costa Glen Building D (Hillside Building) Subject Levante Street West Sidewalk Dear Mr Dreibelbis As a follow up to our onsite meeting of October 24, 2006, to find a potential workable solution, to fix the five year old previously approved sidewalk adjacent to a portion of Levante Street, with the City of Carlsbad's concurrence, CLC is prepared to offer the following corrections to the West Levante sidewalk 1 At the top (South) of West Levante and the intersection of Silverleaf Circle, CLC will agree to remove the "non conforming" ramped area that leads to the pedestrian cross walk to the Commons Building and install a similar ramp m this area but one that substantially conforms to the City allowable slopes and cross slopes Please see Area "A" designated on the attached area site plan 2 Continuing Life Communities (CLC) agrees to remove and replace the center section of four foot wide sidewalk that exceeds a two percent cross slope with a five foot wide sidewalk that does not exceed two percent cross slope Please see Area "B" designated on the attached area site plan 3 At the bottom (North) of West Levante and the intersection of Rush Rose Drive CLC will agree to remove the "non conforming" ramped area that leads to the pedestrian cross walk to the North Entry Gate area and install a similar ramp in this area but one that substantially conforms to the City allowable slopes and cross slopes Please see Area "C" designated on the attached area site plan Mr Dreibelbis, if you are in agreement with the proposed design solution as outlined above, please indicate your agreement by signing the letter below where designated and returning to me at the CLC office If you have questions, I can be reached at 760-704- 6252 1940 Levante Street ~ Carlsbad, CA 92009 TEL 760-704-6300 - FAX 760 704-6262 www continumghfe com I aman agreement with the abpve outlined design Mr Pete Dreilbelbis, Building Inspector Thank you in advance for your attention to this matter Sincerely, Gary E Kutz Vice President - Independent Living Development Date Attachment RECEIVED JUL 1 2 Z006 THE WEITZ COMPANY July II, 2006 Adam Dillavou Weitz Company 1940 Levante Street Carlsbad, CA 92009 Re: La Costa Glen "Hillside" RFI #242 GECG Job No. 60647-572 Dear Mr. Dillavou, Pursuant to your request regarding the above captioned project, we re-submit our response to RFI #242. If you have any questions please do not hesitate to contact this office. Sincerely, GOUVIS ENGINEERING CONSULTING GROUP, INC. Bill Sauers Project Manager Attachments (2) Mansour Amid, P.E. Executive Vice President L 11 2006 949.752.1612 Fax 949.752.5321 4400 Campus Drive Newport Beach, CA 92660 Las Vegas, NV Palm Springs, CA Pleasanton, CA Sacramento, CA Ho Chi Minh City GOUVIS engineering consulting group,inc, B-5 Job : 60647-202 Ran : PLANT Client ; KTGY Group, he Engineer: Steve_S Date : 07/09/2004{Ver7JO} CBC200I(ZONE 4) Beam ID: 3 FL BM @ ROOF, ALT. Loads (Downward +) Beam Weight 30.0 PLf FROM O.ff TO I9.S1 Primary Roof 741 nf-39.0tx(!8+20)/2fnm 0.00'to 19.50' Point LoadfP I) from left sup/wr of BM 2 @ 9.50 T :Point Load Location PI* ^ 19.50' 9.501 I T Down (DL+LUMax.) Up (DL+LUMax.) 7965/7965 0/0 7900/7900 0/0 *** USE GLB 24F V4 5 1/8 x 18 (Fb=2400 Fv=l95) *** *** W/ Iefc2-2x6 trimmer/stud rightZ-2x6 trimmer/stud ***0.375" Camber Up @ Spanf 9.8') Cr/tKO/ Sheor = 6655 tB @ 1.63' 1.5 x Shear/(Fvx A)=0.457 (Fv=244A= 92.25) CriUcd Moment = 44853 LA x FT @ 9-50' Rotio=0.69fl fFb= 2766 S= 276.75) Critico/ Deflection - -0.647 INCH @ 9.75' Based on (U 240) = 0.975 DiagraniE of die Controlling Load Combination, Reflecting the Critical Values Respectively. Shear Diagram DL + FLJ. + RF_L 6855 Moment Diagram DL + FL_L + RF_L 44B53 Deflection Diagram DL+LL -0.647 GO i v i s engineering consulting group,inc. B-7 Job ; 60647-202 Plan : PLANT Client : KTGY Group, Inc Engineer Steve_S Date : 07/09/2004(Ver7.30) CBC200I(ZONE 4) Beam ID: 4 PL BM @ ROOF, Alt. Loads (Downward +) Beam Weight 40.0 nf FROM O.D' 70 28.5' Point LoadfP I) From /efl support of BA1 3 @26.50 T :Point Load Location PI / 1181/11 \ 28.50' 14.50' SI 0/0 t 8662/8662 0/0 Down (DL+LUMax.) Up (DL+LUKax.) *** USE GLB 24F Y4 51/8x18 (Fb=2400 Fv= 19S) *** *** W/ righc2-2x6 trimmer/stud ***0.37S" Camber Up @ Span(J5.5') Critical Shear = -3597 L& @ 26.68' i.Sx Sheor/ffvx AJ=D.J73 (Fv=244 A= 92.25) Critical Moment = / 7244 L£xFT@ 26.50' Ratio-0.279 (fb- 26S2 S= 276,75) Critical Deflection = -0.477 INCH @ 15.75' Based on (U 240) = 1.425 Diagrams of the Controlling toad Combination, Reflecting the Critical Values Respectively. Shear Diagram DL + FL_L + RF_L Moment Diagram Dl_+FL_L + RFJ_ -as 97 17144 Deflection Diagram DL + LL -0.477 11200 Sent By: Pacific Coast Steel, Inc.;619 287 1574;Dec-14-05 12:24PM;Page 1/3 FACSIMILE TRANSMITTAL SHEET TO: JAKE SANTOS /DrewOlwell FROM: Ron Hudgins COMPANY: Bighorn Construction TITLE: Sales FAX NUMBER: 760-479-1770 DATE: DECEMBBR 14, 2005 PHONE NUMBER:TOTAL NO. OF PAGES INCLUDING COVER: 3 RE:DETAIL 1/SD1 ... COLUMNS @ CARPORTS LA COSTA GLEN PHASE HI Jake / Drew: Enclosed you will find our RFI concerning detail 1/SD1 for the carports at La Costa Glen Phase DI. Please feel free to call me at (619) 241 -7631 with say questions you may have. Thank you Ron Hudgins 7155 MISSION GORGE ROAD, SAN DIEGO, CA 92120 (619) 241-7631, FAX (619) 582-2996 »y:£acmc Coast Steel, inc.; 6192671574; Deo-14-05 12:24PM;Page 2/3 KTGY CROUP, INC. Architecture pJanntojL 1799Z MKChflll South IrvttM, 949/BS1-Z133 FROM:Axel Stoltz Transmit ta/ DATE: PRCUECT: La Costa Glen Phase HI Q DUlUJtnjP D Central Phoi Sr PROJECT NO: 2004032 To: OatiR Hilaf LIT* Comaiunfttcc, LLC Fuller* «.CA 92835 714-25S-IOM F«: a ;i40n Wibon lit D C*mmiglft( LHc ComrnnMitif*, LLC 7fiO-704^2«2 , 7«0-7lO-«66 760-704-6500c 8 GaryKmr, 7W-7ICW252 2SOOKiohelwn Or, Suite 12S 949-2W-0023 FAX: 9^9-250-0043 Q Jvnec M. n D M9-75M612 ext 2« F«« 9«»-7S2^32l Q Mike Hotuhnonda TKSC I79tl Van Ktonun Aventw, Suite 250 Fax; 34JO frvifM Aveaut $w« 200 Newport B«ch, CA92«60Olfi» Siwley 8.CI D 2710 L >ka- Avenue West, Suite 100 C*l* Mttrloa CWtli (Mid AswcUta 4l32-ADt!K*yA>o«ie Tht Weki C»«pMiy (Job Slu) 760-931-7700 Fui 760-93I-WTO D G Jorge O'Day D CithyOUon 310 927-7200 FM: 310 823-5803 D Jffl I. Colo D CollMANeibona ___ , .CA 92009 76M79-002P Fta: 760-X79-1770 Q Erin Ve / (tncludu TrftnnniRal Cover) 'Iption: Di awing* Ord«r Shop Drw/lng Prints 5ampl*s Q Shop Drawing Reproduction* Utxsk ottwr Date Rev No.Pages Description Q Q F«<r Review/Comment Distribution For Your Record* A«knowi««aae Return Enclosures to U* Sent By: Pacific Coast Steel, Inc.; 619 287 1574; Dec-14-05 12:24PM; Page 3/3 ._ N0V-0I-2II! |0:OUM FMKMMt0WIWEHIHC MKSHJ21 T-214 P.OOZ/V92 FHIT PACIFIC COAST STEEL, INC, FACSIMILE TKAKSMITTAL 6HE1T "G: AXELSTOL1Z now KITTY Grrap, lac JMTft 11/7/05 C RE: LA COSTA GLEN CARPORTS RFJ04 DETAIL I/SIH fl» THE COLUMNS % THE CARPORTS GALLS FOKM7IB9 @3"O.C. WTIH3TIE3@1 V4rt$lTO?. IN UEU OF THE TIES SHOWN, CAN WB USE *4 SPIRAL WITH 3PPTTCH ADDING 1 W* TURKS TOP AKD BOTTOM? PLEASE CONFIRM. ,7 7155 MISSION OQROfi ROAD, SAN DJEGO, CA 92110-1130 (613) 216-3*05, FAX («19) 2«*-3£03 ar *d 6S:60 03(1 9002-60-AQN 61922431853 PCSBACKUP PCS ALTERNATE FAX6192431853 12:03:29 p.m. 10-27-2005 1 h OCT-H-MOfi V'.itTHI FROM-CDUVIS EHCmltlNG 948-7SZ-S32I T-MO P.003/003 MIT REQUEST FOR INFORMATION KROM: RonHudgms COMPANY; Gouvia Engineering TITLE: Sales FAX NUMBER: 949-752-5321 DATB: OCTOBER 26, 2005 PHONE NUMBER; 949-732-1612 TOTAL NO. OF PAGES INCLUDING COVER: 1 RE:LA COSTA GLEN / CENTRAL PLANT F14.0 Jrfiks: As pec our conversation, I would like to find the con»ctrdnfercementfcrPadF14*Q?Otttfae i acting schedule it states 5-#6 b« long A short. The plwa also show & cut 10/SD3«4uch does t at exist Cut 12/SD3 shows #5 @ 12' on center. Can you please codfinn Ae oonect Ilewoonfirm ASAP. Fed free to call me at (619) 241-7631 wifliaay questions younuy hove, Thenkyou 20/30 'd 7155 MISSION GORGE ROAD, SAN DIEGO, CA 92120 (619) 241-7631, FAX (619) 582-2996 •OH S003-92-100 11/07/2005 20:52 7604383991 MELCHIDR LAND SURVEY PAGE 02/03 MELCHIOR LAND SURVEYING INC. JN2725 Fax: 760-479-1770 November 8, 2005 Weitz Company C/OWeitz Trailer 1940 Levante Street Carlsbad, CA 92009 Attn: Jake Yamanoho RE: La Costa Glen - Central Plant Building Form Certification Northerly Portion Dear Jake: Melchior Land Surveying, Inc. performed a Survey of the Forms on aportion of the above referenced building on 11-7-05 and found it to be in substantial conformance with the Grading Plans, Drawing Number 419-9A. The elevations on the Forms are generally +/- 0.05 feet of plan grade for finish floor (75.70') and +/- 0.10' feet horizontally. See Attachment. This letter does not certify that all forms are correct per the Architect Plans. If you have any questions, please call. Sincerely, Melchior Land Surveying, Inc. Dale A. Davis, P.L.S. Associate Surveyor Attachment: 20* Scale Plat MAIN OFFICE: 5731 PALMER WAY • SUITE G • CARLSBAD, CA 92010 [760) 438-1726 • FAX (76Q) 438-3991 rnlsi@pacbell.nst LS. 461 11/87/2005 20:52 7604383991 MELCHIOR LAND SURVEY PAGE 03/03 -~-~*~—=*<, CENTRAL PLANT 11/28/2005 23:07 7684383991 MELCHIQR LAND SURVEY PAGE 01/02 MELCHIGR LAND SURVEYING INC. November 29, 2005 \Veitz Company C/O Weitz Trailer 1940 Levante Street Carlsbad, CA 92009 Attn; Jake Yamanoho JN2725 Fax: 760-479-1770 RE: Dear Jake: La Costa Glen - Central Plant Building Form Certification Westerly Portion Melchior Land Surveying, Inc. performed a Survey of the Forms on a portion of the above referenced building on 11-23-05 and found it to be in substantial conformance with the Grading Plans, Drawing Number 419-9A The elevations on the Forms are generally +/- 0.05 feet of plan grade for finish floor (75.70') and +/- 0.10* feet horizontally. Si* Attachment. This letter does not certify that all forms are correct per the Architect Plans. If you have any questions, please call Sincerely, Melchior Land Surveying, Inc. Dale A. Davis, P.L.S. Associate Surveyor Attachment: 20' Scale Plat MAIN OFFICE: 5731 PALMER WAY • SUITE G • CARLSBAD, CA 92010 [76O) 439-1726 • FAX [7BO] 43B-3991 mlsi@pBcbell.net LS. 46' 11/28/2065 23:07 7604383991 MELCHIDR LAND SURVEY PAGE 02/02 CEJTTRALJPLANT Sent By: Pacific Coast Steel, Inc.;619 287 1574;Jan-12-06 1:08PM;Page 1/2 KTGY GROUP, INC. Architecture ^ _ 1 7992 MttCMtt South Irvlna. CmlHtomta 5261-4 94WBS 1 -Z 1 33 FAX 949/65 1 -S 1 S 6 FROM:Axel Stohz Transmttt&l DATE: PROJECT: La Costa Glen Phase III Q DuiMin$ D O Ccnml Pbnl J*C' DlSTRJBUtlON: To: PROJECT NO: 2004032 OBflHHMtlll Lift Comimiiiliwi, IXC BOO Mi tninghde Drive a MftnW w" MOO'C myux Drive N«*p« 1 &MCh, CA »26SO 949-7SM6I2 txl 22* Fa. 949-752-532) Q HUke Hauihimnd O 27 1 U Liker Avenue W«I. Stfilc 100 CifUbiiJ.CA 920M -66W 70^931-7700 FM: 7(SO-931-MJO D Cwif* O'D*y Q C i*y Olmna Ontlimning Life CaaimuMitlM, LLC 1 940 Ltvwitt Street Q Riefc Aiehcnbrcnnfr, 760-710-6260 D OaryK*tt. 7W-71 0-6252 Q DteJeBwhop, ?60-'MO-*25J Q JimBiihop. 7«t-7lO-*253n TKSC 17V1 1 Von Kitman Avcnw, Suite 250 949 7M-OS.5 PM: 949-756-0927 SSunityS. 5«o Lwryjun C*h Mitritwr Curtll Add A»«el«t« 4 1 32-A Del Key Avenue M»flP» d«l Roy, CA 90292 3:0627-7:00 F»: 310122-5803 Q JillLCak D CoH«n NllbOfl «nu dnl|ii 2SOO MJdwtocn E>r. Suite 1 23 M9J*M»23 Fax- 9d9-250-0043 ' Q Junes M ICeerttm D 3420 k^ina AVMIU* Suite 200 Newpon Bwrti, CA 936«0-Ma9 949452-9995 FM! S4?.Bi2.|657 D W> Z*V™kk Tbc Wdtt Compinr <J*b S't«) CwUtMd.CA 92009 760-<79-002!' FM: 760-479-1770 Q &rwi Vetmotte 'IVtnnniMl Cover) Shop Drawing Prints Samples Ordar 3 Shop Drawtnff Reproductions DisK Oth«r Date Rev No.Dascrlptlon Pur Voor ftequest F< r U««/R»f»r*ne« Ft r Review/Comment For Approval For Di»tritoutkM> For Your Records R«c«>m of Enclosures Rttturn Enclosures to Us Other: 10 *d "ON JW 65:60 S002-60-AON rent By: Pacific Coast Steel, Inc.; 619 287 1574; Jan-12-06 1 :OfiPM; '• - AOV-H-2POJ UrOlW RMMOWU OKINOfffM M»-t12-C3tt FACJIMltl TXANSMItTAt 3JEDUT AHL81QL1Z raw •AX 11/7/05 1 Rfi; LA C05TA GLEN CARTORTS RJIAM oroonrr onauemfcAirrfr aru*Kun.r DETAtt I/SDJ WB USfi*4 SKRAt WTTH 3" PITCH ADDING I W TWINS TOP AND BOTTOM? PLEASE CONFIRM. / Page 2/2 715) MISSION OOKOS ROAD. SAN DIIOO, CA S2J20-H30 (09) 2l*-?40i. FAX cc.cn CK Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone:(858)715-5800 Fax:(858)715-5810 D Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax: (951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File # DSA APPLICATION* Client P.O. # PROJECT* Project Name /c, ^-os/t ^A-v j*S $ sv&t_s-?^s Project Location *T/O */*</& Contractor Building Permit* ^^Fieid Report ' n n iff <^?~ s**~ D Concrete ACI Tech Welding Other Documents Referenced Q Soils Report d Plans Date Type of Equipment Used n«riRity Count Q Sample Type: Moisture Count ^fi^i^ £Lr kLJ <$A <?f0o<? Plan File # ^p^0""'Reinforcing Steel 1 1 CD Masonry Q D Bolting Q il Specs. Date Gage Type Amount Made/Taken: Date Z - Time Arrived Timfi Departed OSHPD # Pre-Post Tensioned Tendon Soils Fireproofing n RFI# Calibration Dates 2 y~tzi G ?*:&& /O 'O$ D Batch Plant 1 1 Foundations HH Metal Decking PI Codes fiagn* Jt'&i f^f This Work DWas D Was Not "*-" :L" ' Inspecte^nested, and Sampled in Accordance With j Requirements of the DSA Approved Documents. The Work Inspected D Met Q Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met n Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, alt oi tHe observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.D Did Not Meet. Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Si Approval signajlJf^Rame / Company X!xReviewed By/ DSA Regional Office: School District: Certification # I Exp. Date Inspector's Name Date Date Reviewed "Architect Structural Engineer Project Inspector DSA n Testing Engineers - U.S. 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone:(858)715-5800 Fax:(858)715-5810 (Tut-) Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone: (951)677-0366 Fax:(951)677-5761 -DSA File # DSA APPLICATION* Client P.O. # NTP# PROJECT* CONSTRUCTION INSPECTION REPORT Project Name V A Project Location ' "-^ Contractor kl t- Building Permit # Documents Referenced Type of Equipment Used Density Count D Sample Type: <-'- OST A <^, Ut N^ o I t VAN! 7%. -ST. /c^ T t Field Report O n Concrete Q ACI Tech d Welding D Othnr O Soils Report d Plans Date ^ f1- L^=» P^A C> C /*• Plan File # O Reinforcing Steel O C3 Masonry ^ D Bolting D PI Specs. Date Amount Made/Taken: Date -2-1 FE Time Arrived ' Time Departed QSHPn* Pre-Post Tensioned Tendon Soils Fireproofing n RR* Calibration Dates -E> 2.0 0(& LOO c,c o n Batch Plant d3 Foundations n Metal Decking n Gage* Codes IP F ^£c3^.i^-£T.A c D up UJAV of c' e~ K.V i r- AL PLANJT . A CP- A tLQ&€.1> T'Q This Work KWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected 0 Met D Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.Met D Did Not Meet. Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Signature DSA Regional Office: School District: Certification # / Exp. Date Inspector's Name Approval signature / Name / Company Reviewed by Date. Date Reviewed Copy to: Architect Structural Engineer Project Inspector DSA n Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murriota, California 92562 Phone: (951)677-0366 Fax:(951)677-5761 -U.S. Labs Court, Suite 18 11 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION if Client P.O. # NTp# PROJECT #/01-77Z Date. Time Arrived. Plan File*. Time Departed, OSHPD # Notice to Comply NC #-Date Cleared. Concrete ACtTech Q Q Reinforcing Steel CJ" Masonry D Bolting Other.Weather., ! - .,. • : • . - -,-;-r*- ;. - ^ / JT __ *nto R*terenced [p Sojje Sep-oft Q Plans Date ///-y t£5 D Specs. Q Pre-Post Tensioned Tendon [J Batch Plant Q Soils Q Foundations CD Fireproofing Q Metal Decking Man Power Motetun Count Date Q D Codes Calibration Dates. Gage Type..Gage*. Amount Made/Taken: ThtoWoA DWas Q Was Not »d. Tested, anct Sampled In Accordance With Duments. The Work Inspected D Met Q Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Did Not meat the Requirements of the DSA Documents. The Work Sampled D Met Q Did Not meet the Requirements of the DSA Documents. l.'Tb 8w best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with i workmanship provisions of the Applicable code.D Met D Did Not Meet. ^Project Architect: Inspector of UecWd: Inspector'* Signature Reviewed by DSA Regional Office: School District: Certification #/ Exp. Date Inspector's Name C L /-•' //-y 7- fftA..l-f^&r Date Reviewed 'I ' Project Inspector wil iif:' - - i .-^-'i--P®* SlM^ J-^ibX-Jl.V-f^.;^;^... , ' D Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone: (858) 7t5-5800 Fax: (858) 715-5810 a Testing Engineers - Inland Empire 41146 Elm Street. Suite A Murrieta, California 92562 Phone: (951) 677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. # NTP# PROJECT* Pmjact Name %-i/>i , Pmtect Location i ^7 Contractor \_JLi £ Building Permit* C C (^ -TTTft &--£. *? Ci X ^~,.^-s y*s orTJ" -i-i-t ^Ci^-^p *. «> ^^^^o^- \~fyfMQ Report Q Q Concrete -D ACITech D WekJIng PI nthar Documents Referenced Q Type of Equipment Used rtansMyrmint n Sample Type: Solte Report E3 Plans Date ""SvatA <7 ^^ _iTT-*».»vt X'jA/C C^? ^^:A f/yt-lV. rJb4 -S f'-C A^AT Plan Rle # Q Reinfordng Steel G H^Masonry Lj D Bolting G Waalhor l~~l Specs. Date /H ^,J Date QL 1 TTmeArriwed Time Departed OSHPD* Pre-Post Tensroned Tendon Soils Fjreproofing PI RR# nalihratlon Dates ^1 O <-> 3 G G G ?* Batch Plant Foundations Metal Decking PI Codes fi«ns# Amount Made/Taken: C A- n - u 3 "Tk iXg - op . f ft C <g,f M. This Work DWas D Was Not Inspected, Tested, and Sampled In Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met D DWNot Meet the Requirements of the DSA Documents. The Work Tested D Met D DidNotmeet the Requirements of the DSA Documents. The Work Sampled D Met D CWhM meet the Requirements of tfw DSA Ckxamients. CERTIFICATION OP COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance wfth the approved plans and specifications and the workmanship provisions of the Applicable code.fl Did Not MeatLJ Cc: Project Architect: Structural Engineer Inspector of Record: School District: Certiflcatton#/Exp. Date ?T*'^Date Raviewftri Copy to:Architect Structural Engineer Project Inspector DSA **tlfig Engineers - U.S. Labs 895 Convoy Court, Suite 18 San Diego, California 92111 Phone: (858) 715-5800 Fax:(858)715-5810 D Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION # Client P.O. # NTP# PROJECT* Project Location Contractor Building Permit # \ Documents Referenced Type of Equipment Used rtansfly Count Q Sample Type: ft L^>ST>t L, L/Zf^. I/ '70 S>ti-UXtZL£AP £<#£<.& <• L^£lT^ CL&Obm^ 1 Plan Fife* Field Report Q Notice to Comply D Concrete J^ D ACITech D D Welding D |~| nthor I~1 Sons Report PI Plans Date , - Data 1 / ^ /~AAL<,RAf) <Z*» TimeAniwid ' Time Departed OSHPH* NC # Pnta Cleared ?Relnfofcing Steel O Pre-Post Tenstonad Tendon Masonry Q Softs Bolting D Flreproofing Fl Specs. Data PI RFI * Calibration Dales Amount Made/Taken: ///«-> b 1 £ -&£> Q Batch Plant Q Foundations Q Metal Decking n ftaoa* Codes IL I^SDI 11 t££fAP& ^a (\/&&T\BAA* ThisWork DWas D Was Not Inspected,.Tested, and Sarr^ited in Accordance VVith Requirements of the DSA Approved Documents. The Work Inspected D Met Q DW Not Meet the Requirements of the DSA Documents. TheWork Tested D Met D DM Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. ' CERTIFICATION OF COMPLIANCE: To the best of my knowledge, aH of the observed work, unless otherwise stated, fs in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.Q Did Not Meet. Cc: Project Architect: Structural Engineer Inspector of Record: Inspector's Signature _ Approval signature / Reviewed by Ai/4 Copy to:Architect Structural Engineer Project Inspector DSA DSA Regional Office: School District: Certification #/ Exp. Date Inspector's Name ^Testing ^ 7885 Convoy Court > 18 San Diego, Calif ornV-02111 Phone:(858)715-5800 Fax:(858)715-5810 D Testing Engineers - Inland Empl^ \ Q Testing Engineers - Palm Sfirings 41146 Elm Street, Suite A ', i 820 Research Drive, Suite 2 Murrieta, California 92562 'T^T . Palm Springs, California 92262 Phone: (951) 677-0366 Phone: (760) 325-8378 Fax: (951) 677-5761 Fax: (760) 325-7480 Q FIELD REPORT Q NOTICE TO COMPLY DSA File f DSAApp.# Page of TO: Date /-.r ot Permit Number Job Number y-plG^ Plan Fite Number Address Project: />-**A. /~ • II i _,fi '&'**& &r™*r-J . / " >vi^ «i/7" -« a -** Q -e- £opyjs: Architect ^.Structural Engineer Project Inspector DSA THE WORK:WAS WAS NOT INSPECTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE DSA APPROVED DOCUMENTS. THE WORK INSPECTED: Q MET £] DID THE REQUIREMENTS OF THE DSA APPROVED DOCUMENTS. ;-..!. ••' Project Location * Building Permit* ^A Documents Referenced Type of Equipment Uset Testing Engineers - U.S. Labs a Testing Engineers - Inland Empire DCA ri|0 # 7895 Convoy Court, Suite 18 4114$ blm Street, Suite A SnnPiftgo ^alifAmia °?111 Mu^a i>nfnmta QPW? D8A APPLICATION* Phone: (858) 715-5800 Phone: (951) 677-0366 C|jent PO # Fax: (8b8) / 1 b-58 1 0 Fax: (95 1 ) 677-576 1 NTP* PROJECT* 1 T:rt&tL.. CONSTRUCTION INSPECTION REPORT ' ' ( r~*^ A A. A^'v^ f ' ^f>^ \CfcA \^WM^ Date {-H'fo "f. " i-^VyA^^ *^" ^'^ » C ACV^VS^cr^1 C J^ TimeArriwed " VT 2. / \ ^ . fl~,V (^>Ss.\A Tima Departarf ^> ^C^r-t.^CH Plan File* OSHPD* Q Concrete [Xj Reinforcing Steel Q Pre-Post Tenstoned Tendon Q Batch Plant n ACITech D Masonry D Soils Q Foundations D WekSng Q Bolttng Q Flreproofing Q Metal Decking |^] Othftr f ?* V^ Wlaathftr Man Pnu^ar G Soils Report f^ Plans Date J' O"^ H Specs. Date !~1 RFI# (VJ Codas lAJ.r:* ") ^1 f".1? -' ttrV^A^T Calibration natAs Mntetiim r^itint Rage Typ* ftaga * Amount Made/Taken: V C •<••• ThteWork [3 Was n Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the 96A Approved Documents. The Worlc Inspected 0 Met Q Did Not Meet the Requirements oflheWADocuments. The Work Tested D Met Q Did ftot meet tr« Requirements of the DSA Documents, The Work Sampled D Met D Did Not meet the Requirements of theDSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.Q DkJNotMeet. Cc: Project Architect: Structural Engineer: Inspector of Record: \s *\ r v%~ > ' '• * ? C \'J\ Inspector's Sign. Approval signature / Name / Com Reviewed by Copy to: Architect Structural Engineer Project Inspector DSA UbAKuybneJUfflw ScTiSbi UBWct CerMflcatfon # / Exp. Date Inspector's Name Date. 'ate Reviewed X Tasting Engineers - U.S. Labs , * 7895 Convoy Court, Suite 16 San Diego, California 92111 Phone: (858) 715-5800 Fax:(856)715-5810 a Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT Client P.O. * NTP# PROJECT* Pm)»fit Name A*A ff^^'&A- •/^— *— SU-^V. Pmjftrt Location |^ ILy' t-^l./Av* A~££^ ^7 R,.iHinnPBrmit *<""_. VSO MM ^O M (3 Field Report D (3 Concrete Q ACITech D Weldina H o*" VjjrtYtf i^,,r Documents Referenced Qt Sofls Report [S Plans Date Type of Equlpmanl Usad \J C M (. J , A O ' 1 <*& nanstty roiint , Uniafiira r^wint P Sample Type: ( -^<xA.f^\ W'>V ^ * — Data C^' 'C3 L O^VnlvOl *^A TlmaAfTivfld t C PlanRIa* OSHPDJf D Reinforcing Steel D Pre-Post Tenskxwd Tendon •0 Masonry Q SoHs D Bolting D Rreproofing :, Wa^^iar Uan Pntwar zr^- tf !~i Soecs.Date f~l RFI# r-nO CCL&Al - nalhration DatAA ftaoaTypft Amount Made/Taken: exz> \(0& <w 1&& D Batch Plant Q Foundations G Metal Decking W Codes R»p»* ( ftl4_i±A \\ i _^ This Work 0Was D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the£6A Approved Documents. The Work Inspected H Met D DriNd Meet the Requirements o( the QftVDocunwts. The Work Tested D Met D DW Not meet the Requirements of the DSA Documents. The Work Sampled D Met D DM Not meet the Requirements of the DSA Documents. CHplBCATlON OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is In Confbrmance with - thtf approved plans and specifications and the workmanship provisions of the Applicable code.H" Met D Did Not Meet. Cc: Project Architect: Structural Engineer: Inspector of Record: P8A OfflM Oulmul Ptouiu. Certification # / Exp. Date Inspector's Signature Approval signature /Name/ Company Reviewed by Copy to:Architect Structural Engineer Project inspector DSA n Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 16 San Diego, California 92111 Phone:(858)715-5800 Fax:(858)715-5810 D Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. # NTP# PROJECT* I Pp>j«* Mama L/\ fAG.'Tft f*LJ5*J Hate /2-~ 2- 1~~U *^ " Project Location Contractor ^TfWv/ Rnllriing Parmlt # Tim*, Arrived "7 * ©-O A/"_osri^ ffl^FtoU Report D Nota Q Concrete Q ACITech D Welding n ™w Documents Referenced D Type of Equipment Used l-lanotty Hnimt D Sample Type: Soils Report Q Plans Date Mntefiim fMtm\ PtonFlla* 9 to Comply NO # d Reinforcing Steel S&* Masonry £pi ^Q Bolting WMllhM I~~l Soecs. Date GaaaTvpe ^TlmftHApartaH* OKHPn * Pate ^Icorod D Pre-Post Tenstoned Tendon D Soils C3 Fireprooflng ManPrwBr PI RFI# Amount Made/Taken: ^30 D Batch Plant Q Foundations D Metal Decking -Gaoe* £( &**$£, )A$ i ^ **!*<&& 'This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met D Did rW Meet the Requirements of the DSA Documente. The Work Tested D Met D DWNotmeetmeReo^remerteofrheDSAr^xwrrwrrts. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documente. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.DDkl Not Meet Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Signature Approval signature / Nai Reviewed by DSA Regional Office: School District: Certification # / Exp. Date Inspector's Name Date. Date Reviewed Architect Structural Engineer Project Inspector DSA D Testing Engineers - U.S. Labs 7695 Convoy Court, Suite 16 San Diego, Catfomia 92111 Phone: (658)715-5800 Fax:(858)715-5810 a Testing Engineers - Inland Empire 41146 Elm Street. Suite A Murrieta, California 92562 Phone: (951) 677-0386 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSAFrte* DSAAPPLICATION* Client P.O. # NTP# PROJECT* . , O Q fa o^rA A* ReWReport D Notice to Compty NC#.Date Cleared. Q Concrete D ACITecri D WsfcSng Q Reinforcing Steel D Masonry D O Pw-Posffenstoned Tendon Q BatehPtont O Sorts Q Foundations O Ftreprooflng Q Metal Decking This Work DWas D Was Not kispected. Tested, and Sampled in Aecwdanee With . Requirements of the BSA Approved Docoments. The Work Inspected The Work Tested a a GifilTRCA'lftOH OF COMPLIANCE: To the best of my knowtedgs, aH of the obseiyediwwk, untessotherwise stated, (s in Conforrnance wffii th^ apprpved plans and specifications and the workmanship provisions of the Appficabte code. «DDkJNqtMeet. Cc: Project Architect: Structural Engineer Inspector of Record: inspector!* Signature Approval Signature / fteife/ Company Reviewed by DSA Regional Office: School District: Certification * / Exp. Date .—Inspector's Name Date. DateReviawed Architect Structural Engineer Project Inspector DSA Testing Engineers - U.S. Labs. 7895 Convoy Court, Suite 18 San Diego, California 92111 * Phone: (858) 715-5800 Fax:(858)715-5810 a Testing Engineers - Inland Empire 41146 Elm Street, Suite A t Murrieta, California 92562 * Phone:(951)677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. # NTP* PROJECT* /<*Q "7~7 -t Pmjact Mama i- A ^ c, A C\ ^ •* i <? ^ Pmfart Location / O ? => 1<^ t' ^ K, - ^<L. * j r^ntrartor U \ C -t"Z- Ruilrling Parmtt * B^iekt Report d Q Concrete D ACITech D Welding f~] Ottwr Documents Referenced Q Soils Report Q Plans Date Q Sample Type: Zt^ i l£-(. \' _L> C PlanFfe* \£ Reinforcing Steel O D Masonry Q D BoWng D PI Specs. Date na^Tyr* Amount Made/Taken: Data ; f~ /^ TlmaAirived / Time Departed OSHPD* Pre-Post Tenskmed Tendon Soils FtrepTooflng MflP P"-«"' n RFI* r-lihraMon nah« o/c <~ /j"1. Vi f> jj ,' c"1 C3 Q Batch Plant Q Foundations D Metal Decking PI Codes ftnga* . 3 U,*-t "C'CA*^ *•>• ^./r' "T- « i 1 /I ThisWortc D Was O Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met G Did Not Meet the Requirements of 8w DSA Documents. TheWork Tested D Met Q Dtd Nrt rneet the Requirements ot the DSA Documents. The Woric Sampled D Met D DkJNrt meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.SlitotD Did Not Meat Cc: Project Architect" Structural Engineer Inspector of Record: Inspector's Signature Approval signature / Name / Company Reviewed by DSA Regional Offtee: School District: ' >> r* I . ^ J ^-^.JC.i-'C Certification #/Exp. Date Inspector's Name Cr-'OV^i Date. Date Reviewed Copy to: Architect Structural Engineer Project Inspector DSA a Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone; (858) 715-5800 Fax:(858)715-5810 D Testing Engineers • Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. # NTP# PROJECT* PmJBrtNflmB / t- ( arfe f~.lt*. ~ M<flL M^/*-/l?y /^f><' //? Pmjftrt 1 nralinn |fj*/i / i\ . ^ > ' v-V^V/ L f, -. f C.&fnL&d CA %'W ~r{ f \ / • i r 'fVwrtrafitiy J n " s,Vf 1*7 I fi^,.-ff..,-y Ruilding Parmlt* C ^ (W*j t$f Plan FJta* [SI FiftW Rftport D Notinn to Comply NO # Data fJ-Sf'/fif '?*? TlmeArrivad //-^L - Time Dflpflrted f *0Ofi, »^ „ f C] Concrete Q Reinforcing Steel Q Pro-Post Tenstoned Tendon D Batch Plant Q ACI Tech @* Masonry D Soils D Foundations C] Welding D Bolting - EH . Rreproofing CD Metal Decking Documente Referenced D Soils Ftaport I^f Plans Date & .;]f-l'/-ff' FT Specs. Date *t/(M l~l RFI# NT Codes D Sampto Typ*: — ^ \ 1 PL t -~~~ CL* f fSc^/7?- CP eye //^ L r /• M ^ • i1 D" 1 yi'lfl'SC'nrf y f\a\ \ i *., \V.t{\ ,t y •. ,» ft ;< *•; | ^.f r .vt, M (C/if7..i« 1 (Ifc i f?s.^.( /lAf, i ^ r iffii'i if// Kf_^i,,A 1 ( / f J irt rifllibrattrm nates ftogo Typo ftan« * Amount Made/Taken: ' ^~ u.-tl !i 'r"f^ ! ft/ f •. ^ yM.I;^ Af\ frkot: * f« / /# '- V ^/.-// /, „ i <: A /L'/. (Opksl L We^K. f< t ^fi*fr c-/ SS'.lt'f^ a* ri t/^f /K u/a// /^^>f i /r./1 /Ai^ ( fifllt** \t\\«stf f0S/fr 'kj This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met Q Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Dto Not meet the Requirements of the DSA Documents. The Work Sampted***0iMet Q Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is In Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.Met Q Did Not Meet Cc: Project Architect; Structural Engineer Inspector of Record: i"e, JT ' J> '" T- jr. ^j r^^^s ^.,- if_a. i_j. r-.-..i.4f •-'-•-" "(f^' Inspector's Signature _ Approval signature / Name / Company Reviewed by Architect Structural Engineer Project Inspector DSA DSA Regional Office: School District: Certification #/ Exp. Date Inspector's Name Date Reviewed f-ftc Date. at Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone:(858)715-5800 Fax:(858)715-5810 G Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax: (951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File # DSA APPLICATION* Client P.O. # NTP# PROJECT* * Torf* (*ffi* — AfnrJL PrvirtOrtb PLa<f 77T Projflnt Location (9*tf \^».f$\isnnA j *\-**\ Cilnj tlfff* t ' r~ (f/JtJ^f Contractor / ke WftTt C *»/»»*" Building Permit # C- CflfliW^oi / PlanFita* Date (%/7/^5~ TimeArrivfid lfUtit,^ t Time Dfipartsd 7 <JUt>,i^* OSHPn * ' I j Concrete | | Reinforcing Steel |~1 Pre-Post Tensioned Tendon 1 1 Batch Plant Q ACI Tech 15£ Masonry Q Soils CD Foundations Q Welding O Bolting O Fireproofing D Metal Decking n C . Jf 1 CiT) nnrumfints RRfamnrflrl l~~l Snils R«nnrt R<T Plans Date fi^.") £Al//fl5" TST Soecs. Date ^?X^7V Type of Equipment Us ( -PoT f~fl I £^<T>fe»ftM PI RFI # 1ST Codes flrtV — FZttotlJ-^ ( $Lfl(>t IIS-C.P. (A ) r\J fou/- irr amuTflr/ ThO CJML/ VA/TI/K rur fkp A\JfK /JAOr \n*i WLI KGOM\ q«* j (I'D/ o^A yvVA .//gr?r. ThpiMlrtw K^m Ui '/ /^/? T^ "'^ _ flfrw 1-LAtfh fl fff 7/sf Ct>olt'A<fT<iwf>r Yard fw/ r/*^ yftUifc v/tf/f f/»Ay,|TKg / /i»r Jb ofy<> low- r,.if—r X«/>r/; g /V<rma way runtffft frinT V This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met D Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.ST Met D Did Not Meet. K / y \Cc: Project Architect: Structural Engineer: Js Inspector of Record: Inspector's Signature Approval signature / Name / Company Reviewed by DSA Regional Office: School District: Certification # I Exp. Date Inspector's Name Date,, Date Reviewed Copy to: Architect Structural Engineer Project Inspector n Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone: (858)715-5800 Fax: (858)715-5810 D Testing Engineers - Inland Empire 4114€*Elm Street, Suite A Murrieta, California 92562 Phone: (951)677-0366 Fax: (951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File # DSA APPLICATION* Client P.O. # NTP* PROJECT* Project Name U- f\ L Project Location 1 \^\ Contractor ~i Ruildinq Permit # 0<,lA /Li F^J D /.fx/A-v/Tf r^ VS-r^nopI fM Field Report O r~| Concrete D ACI Tech D Welding l~1 OthPr Documents Referenced C Type of Equipment Used Density Count Q Sample Type: Soils Report dl Plans Date Moisture Cnnnt <"' Plan File # Notice to Comply A? D D Date / t- - S Time Arrived "-, Time Departed^, OSHPD # ffyf'Reinforcing Steel £Q Pre-Post Tensioned Tendon Masonry i 1 Soils Bolting O Fireproofing PI Soecs. Date l~l RFI# Calibration Dates Amount Made/Taken: ' n\ Q)O .00 Q Batch Plant d Foundations CH Metal Decking n fiSQprf Codes L P.I.ACE/3 Pi AA^ ,W Tr/.y S /J -r^f- / Or A^fA .. __ £- /o ^ /A Qr |A M_ \t AA/T^ I Ti/ i r 71 4- ooter \\AJ"f This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met Q Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.'Met D Did Not Meet. Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Signature ~~i Approval signature / Name / Company Reviewed by DSA Regional Office: School District: Certification # / Exp. Date Inspector's Name Date. Date Reviewed Copy to: Architect Structural Engineer Project Inspector DSA i -••-iJ|Sffij\ " a Testing Engineers - U.S. tabs a Testing Engineers - inland Empire If jCWHfcL^ 7895 Convoy Court, Suite 18 41140 Elm Street, Suite A ' ^HHSl^^SaP Die9°> California 92111 Murrieta, California 92562 • \WH 1 Phone; (858) 715-5800 Phone: (951) 677-0366 JHMPF/ FaxNS58) 71 5-5810 Fax:(951)677-5761^$&s&/ x * I ''-^^^F***^ \ CONSTRUCTION INSPECTION REPORT !. Project Name J.^ Co-*-*'- 'r^l'V M**ffii i \ 1 Project Lor-ation /7^ f / »y-A*,.^»\ S4 |^" &iiildbt0 Permit* CA fiVV^OV \ J^^fcW Report x D :i; CH Concrete ; D ACITech j j; D Wefcfing i ' ' ' . ' ' D Ottwr bocuments Referenced D Soils Report Q Plans Date j i : ': i !Typ& o( Equipment Uaad , '• |p SamptoTyp*: , Pro^il ^ PL X Hi- /< />A t* 1 Plan Rto * DSAFHe* DSA APPLICATION* Client P.O. # NTP* PROJECT* "STl lO^^JOD Date 12- S-0 r" Time Arriuftd Q,(f,3i? ,,, Time rtapartad fwwpn* Q Reinforcing Steel Q Pre-Post Tensioned Tendon Q Batch Plant Q Masonty O Soi's D Foundations Q Sotting Q Fireprooflng D Metal Decking l~l Specs. Date D RFt# !~l Codes 1 Calibration Dab* > Amount Made/Taken: Rao«* ,-.-1t. t t- e ',-/"^.^ (^T^^ ^ *. .-.-._ xi* <*». Li^. itL i *Ar *>. 1 ./,/ / 503//? TT^ ~- ~ ' - "' " ' . _.. /-• • |r t r A ill / C ' ***** ^Jf £ .J V7.!A.^LJ A. J/ TNsWork DWas QWasNot Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work inspected D Met D DkJ Not Meet the Requirements of the DSA .Documents. The Work Tested D Met d DM Not meet the Requirements of the DSA Documents. The Work Sampled D Met Q Did Not meet the Requirements of Me DSA Documents. CERTlFtCATION OF COMPLIANCE: To the best of my knowledge, aH of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.at ITf ran Mmei |||! I i Cc: Project Architect: t;! ' • || -i-i Structural Engineer !' inspector of Record: .. ,- • -f _/ / / / DSA Regional Office: School District: Certification #/Exp. Date /? / , -/Date. Reviewed by Date Reviewer! JEopyto: Architect , ; Structural Engineer Project Inspector DSA Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone:(858)715-5800 Fax:(858)715-5810 D Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax:(951)677-5761 Project Name Project Location Contractor CONSTRUCTION INSPECTION REPORT E>3A APPLICATION # Client P.O. # NTP# PROJECT* 59 Field Report Q Concrete D ACITech D Weldin n Notice to Comply NC#.Date Cleared. Q Reinforcing Steel (51 Masonry O Bolting Weather Pre-Post Tensioned Tendon Q Batch Plant Soils G foundations Ftreproofing O Metal Decking Man Power Documents Referenced |~1 Soils Report C Plans Date Type of Equipment Used Abl&<y cO Q*W Density Count Moisture Count, Q Sample Type: Specs. Date.PI RFI#Codes Calibration Dates. Gage Type. Amount Made/Taken: This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the OSAApproved Documents. The Work Inspected EH Met D Did Not Meet the Requirements of the^6A Documents. The Work Tested G Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Cortformance with the approved plans and specifications and the workmanship provisions of the Applicable code.Q Met D Did Not Meet. Cc: Project Architect: Structural Engineer: Inspector of Record: BOA Rugluiml Odium- Inspector's Signatur Approval signature / Name / Company Reviewed by _ Certification #/ Exp. Date Inspector's Name Date. Date Reviewed Copy to: Architect Structural Engineer Project Inspector DSA t X"" Testing Engineers - U.S. uh*r P Testjjig Engineers, -.jhland-^inpire— • 7895 Convoy Court, Suite 18 } 4T146 Elm Street, Suite A San Diego, California 92111 Murrieta, California 92562 Phone: (858) 715-5800 Phone: (951) 677-0366 Fax: (858) 715-5810 Fax: (951) 677-5761\ / \ CONSTRUCTION INSPECTION REPORT Project Name & Project Location * <=* (^o^1^ &i<** A/^f-fft f4r*s*fJv toix«v»>v o-^^y rf«y ir/ "C*«,^. ^*/ / 1_ . I f Jr A, Building Permit *Plan-File # DSA File # DSA APPLICATION* Client P.O. # NTP* PROJECT* 7*°* Date /S' <3 9 - ° J '<Tts* /-c^^v Time Arrived /•*' Jfl ~ fj~ //r**N Time Departed ' ' ^ OSHPn* I3I Concrete Q Reinforcing Steel Q Pre-Post Tensioned Tendon Q Batch Plant H] ACI Tech CD Masonry [2* Soils d Foundations C3 Welding C] Bottjng HH Fireproofing \ CI Metal Decking Documents Referenced Type of Equipment Used Density (-.mint Q Sample Type: ~J 1 f tf "^ A B?l Soils Report ??l Plans Date -3 ~ V ~ Oy |~1 Specs. Date [~] RFI* v PI Codes L/V J t, •. / ; /^/-o *O Calibration Hates \ Amount Made/Taken: R # \ \ \ \ ^-^r*> Oi>/ +tfg'r. ^ ' C±*- This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met D Did Not Meet the Requirements of the DSA Documents. The Work Tested D Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.D Met D Did Not Meet. Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Signature Approval signature / Name / Company Reviewed by DSA Regional Office: School District: Certification # / Exp. Date Inspector's Name ^Date. Date Reviewed Copy to:Architect Structural Engineer Project Inspector DSA ' -dit '"*•**» Mr^# . K. .gy| • . • ;:.V^ : . Project Location , 'l':\. Contractor v - *'• T > Documents Refers ;; Type of Equipment • .," Density Count '• ' '1 f\ •sVu' f "1 Lf U< • / 6f Testing Engineers - U.S. Labs a Testing Engineers - Inland Empire DSA Fna # 7895 Convoy Court, Suite 18 41146 tlm Street, Sutte A San Piego California 92111 Murrieta California 9?!?6? DSA APPLICATION* Phone: (858) 715-5800 Phone:' (951) 677-0366 C|jent po # Fax: (858) /lb-6810 Fax: (951) 6V/-576I NTP# 7 ' ^ PROJECT* /f^Cf'7^7^~ CONSTRUCTION INSPECTION REPORT ' — , ;- /^/j-/ // •«»— i-Ci f i^S-te, G- fc vv / f? ^-4^(- ( r/*Sn-t* Date ///-S^L /O Tfc / TimeArriv^d X-7 V-.X tO^ * f "Z- / 1 ' i ft Mw A / p ^ S * Time Daparted Q .* O O ^"' ' PlanRte* OSHPD* Q Concrete H^Reinforcing Steel Q Pre-Post Tensioned Tendon D Batch Ptant D AClTech D Masonry D Soils Q Foundattona D Welding D Bolftig Q Flreproofing Q Metal Decking need Fl Sous Report f~l Plans Date PI Specs. Date l~l RFI# T^ Codes "" Arnount Made/taken: ( ( ( -1 c ^ £ * A W<? ( » -L K 4 ^4- -l^lwon *l«.(" C-^ «f-r6 hi^-X^^ ^i,W^ *4 Au.V*/. ^/ * i. ) _L »-*.*^--'x».jfc/l / •-•-» y— • •»--. ~rf~ *-* fi f^ " ThteWortc DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met Q Did Not Meet the Requirements of th%DSA Doconwnte. The Work Tested D Met Q Did Not meet the Requirements of the) DSA Documents. The Work Sampled D Met D DW Not meet the Requirements of m DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provistons of the Applicable code. Cc: Project Architect: Stmctural Engineer: Inspector of Record: Inspector's Signature Approval signature / Name / Company Reviewed by DSA Regional Office: School District: Certification # / Exp. Date Inspector's Name o Date. Date Reviewed Architect Structural Engineer Project Inspector DSA ra TeiTesting Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone: (8SB) 715-5800 Fax:(858)715-5810 D Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrteta, California 92562 Phone:(951)677-0366 Fax: (951) 677-5761 CONSTRUCTION INSPECTION REPORT DSA File # DSA APPLICATION* Client P.O. # NTP* PROJECT* Project Name £. A Project Location Contractor if-Jf i Building Permit # ^ f, ^ 4<U O (c *v / ^ ^ M -\ y C t r/fi n -t" Data / / / -? JL /O "B. / 1 / *~\ < t 1 I ~*5 y" C* T ~7- / * ' > I ^ l*lOi< *V / f^ t ii t/ ^ 1 ' ' PtanRIa* Rannrt f~1 MntiRA tn Tftmnh/ Wn * -nmeA^^ '-p.-net C? * /^ f "^ OSHPD* Q Concrete 0"Reinforcing Steel D Pre-Post Tenstoned Tendon Q Batch Plant O ACITech Q Masonry CD Soils Q Foundations D Weiding n Bolting D Fireproofing D Metal Decking Documents Referenced Q Type of Equipment Used Density ttnimi D Sample Typ*: _T«^c-L( <r €,, UL ^j SoHa Report [~! Plans Date • - . !~1 Specs. Date 1~1 RFI # I~1 Codes .nallhratlnn HatAs • * *™'^w Moisture Count Rage Typa fians * Amount Made/Taken: ^(_ -RrMiii'faWr^' nCt. ro « t «r v r - J^i'./0*T ^/^ &« <T^Z ' T / C / )/ / -he -rc » i* -1-arCiA ^-t<r<L V ?A ^1« /f *, 4 I(J w i ' V ' <-. KAcC.r*-? ex ThisWork QWas DWasNot Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met Q Did Not Meet the Requirements of theJJSA Documents. The Wort Tested D Met D Did Not meet me Requirements of thq DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of ths DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, ail of the observed work, unless otherwise stated. Is In Conformonce with the approved plans and specifications and the workmanship provisions of the Applicable code.Did Not Meet. Cc; Project Architect: Structural Engineer Inspector of Record: Inspector's Signature Approval signature / Name / Company Reviewed by DSA Regional Office: School District: Certification * / Exp. Date Inspector's Name "^^ '{ Date. Date Reviewed Copy to:Architect Structural Engineer Project Inspector DSA Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone: (858) 715-5800 Fax:(858)715-5810 a Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone: (951) 677-0366 Fax: (951) 677-5761 CONSTRUCTION INSPECTION REPORT DSA File # DSA APPLICATION * Client P.O. # NTP# PROJECT*•7X6 OSi Field Report [[] Concrete n ACITech D Wekfing D Other Documents Referenced d SoBs Report Q Plans Date^ «4 I; rYr O Notice to Comply NC#Date Cleared. D Masonry D BolBng Q Pre-Post Tensfoned Tendon Q Batch Plant D Soils D Foundations D Fireproofing D MetalDecking Manpower CD Specs. Date.n D Codes Density Count Q Sample Type: Moisture Count..Gage*. Amount Made/Taken: * &r*Ptr ;/} 0J0 * ' / TMsWorlc DWas OWasNot Inspected, Tested, and Sampled in Accordance With Requirements of the OSA Approved Documents. The Work Inspected D Met D MNo( Meet the RequifBmentsritw DSA Doajments. The Work Tested D Met D Did Not meet the Requirements of tuDSA Documents. The Work Sampled D Met Q Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, al of the observed work, unless otherwise stated, is in Conformance with J*TMet D the approved plans and specifications and the workmanship provisions of the Appflcabte code.Did Not Meet Cc: Project Architect: Structural Engineer Inspector of Record: Inspector's Signature Approval signature / Name / Reviewed by Cjjpyjfl:Architect Structural Engineer Project Inspector DSA DSA Regional Office: School District: Certification #/ Exp. Date Inspector's Name Date Reviewed ' ?7 Date. lj(f*8tlng Engineers - U.S. Labs / T895 Convoy Court, Suite 16 / San Diego, CalHomla 92111 Phone:(858)715-5800 Fax:(858)715-5810 D letting Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone: (951) 677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. * NTP* PROJECT* PmjflrtName £^ G*f&TA ^V-^-J * AJflATV ffc/5^<*TY /^ Bullrilnn Parmlt * O.D OM3 O 4 Plan FIlA * Q( Field Report Q Notice to Comply /" i -L/'LJ Concrete CJj D ACITech Q D Welding Q D Othpr . Documents Rafaraneed H Soils Raport f~l Plans Date Typaftf PnulpmontllRAd ^f57?9 Fl^S ^»^ if^TA^SOf(^Aj£ ^ Q Sample Type: VAC** fY/ f^pT6AL ft AMT* Hata ^^ S^^fl ^ Y#a£>1 Tlma Arrive Tlma D«p*rtflri flRHPD # N^ # ' Pntn Cleared , . . Reinforcing Steel D Pro-Post Tensloned Tendon Masonry Q S0"8 Bolting Q Flreproofiny UUaath^r Man Phui« PI fin** Date l~l RFl * "7^J£. Callbiatlnn Dates RflO»Typ« Amount Made/Taken: ,2^/G*r • fazao. n Bateh Plant C] -Foundations D Metal Decking n Hag** Codes Va»^—?r-rLt-A/j-y S7 V/f x . 0 - C*#Apf X.>1X *' /VO KAit IT"i)taf/. *A) n&p /A) TOsWork DWas DWasNol Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected Q Met Q DM Not Meet the Requirements of the DSA Documents. TheWork Tested D Met D DW Not meet the Requirements of the DSA Docunwitt- The Work Sampled D Met Q DM Not meet the Retirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Contormance with the approved plane and specifications and the workmanship provisions of the Applicable code.D Met D Did Not Meet Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Signature Approval signature / Nap Reviewed by DSA Regional Office: School District: Certification #/ Exp, Date Inspector's Name Company Date Reviewed Copy to:Architect Structural Engineer Project Inspector Date. (\4etO Tasting Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone:(858)715-5800 Fax:(858)715-5810 Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone: (951) 677-0366 Fax:(951)677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION # Client P.O. # NTP# PROJECT* Project Name U A C- PmjAct Location ^A t*~ Contractor . J^lCS" Rnildinn Permit * OSTA 61 ^eM C.S.&AD <sA HoMJ ^oKiS-T- Plan File* [~1 Field Report O Notice to Comply D Concrete Q Q ACI Tech D D Welding d Pi Other Documents -Referenced Q Type of Equipment Used O Sample Type: Soils Report Q Plans Date wr* Reinforcing Steel f~| Masonry QjQ Bolting D Waathar l~~l Specs. Date Amount Made/Taken: Date \C5 O TlmeAmved * Time Departed OSHPH* Pre-Post Tensioned Tendon SoRs Flreproofing ynnPnumr n RFI# CaUbralion Dates CT a-oog 7700 15<?C? Q Batch Plant Q Foundations D Metal Decking PI Codes Gage* eg. H AT LI f TsS . "THAT -Fy\ ThisWork HWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of ttie DSA Approved Documents. The Work Inspected S Met Q Did Not Meet the Requirements of the DSA Documents. TheWork Tested B-Met D Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D Did Not meet the Requirements of the DSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, aH of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.D Did Not Meet. Cc: Project Architect: Structural Engineer Inspector of Record: Inspector's Signature Approval signature / Name / Reviewed by DSA Regional Office: School District Certification # /Exp. Date Inspector's Name Copy to: Date. Architect Structural Engineer Project Inspector DSA '•sting Engineer* - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phone:(858)715-5800 Fax: (858) 715-5810 o Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax: (951) 677-5761 CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. # NTP# PROJECT* Prafaet Location /V, Contractor Lu TO ^i/\JjS^^At^ S**te t£l T2, ttJTHAt. rl-A/tfT Date 1/JL3/QS fJt? tZAfcK/tan X*-X Time Arrived TimaDaoartad 7-•oo BuHrtinoParmft* O.# f)(t&41 L Plan File* OfiHPD* ffl FleW Report Q Notice D Concrete D ACITech D Welding PI Othar Documents Referenced O Type of Equipment Used £1- Density Count D Sample Type: SoHs Report D Plans Date j2Q Reinforcing Steel D Pre-Post Tenstoned Tendon D Masonry Q Sote D Bolting D Flreproofing l~l Soeca. Data PI RR # ttoit&llC^/GZ SrT***. P-allhratlon Data* n a a '" Batch Plant Foundations Metal Decking PI Codaa ftaQMTypa Ran** Amount Made/Taken: 50gfc,tfe'0 lti /V ' P* /A?«y UL ThteWbrk BVtes D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of V* S8fr Approved Documents. The Wock Inspected £JU* D OkiN«^^9( the Requirements o*tr«a9«)ocument8. The Work Tested D Met D DW Not meet the Requirements of to DSA Documents. The Work Sampled D Met D DkJ Not meet the Requirements of the DSA Documente. CERTmCATK>N OF COMPLIANCE: To th* best of my knowledge, all of the observed work, unless otherwise stated, Is In Conformance wtth the approved plans and specifications and the workmanship provisions of the Applicable code.DOid Not Meet Co: Project Architect Structural Engineer Inspector of Record: Inspector's Signature DSA Regional Office: School District: Certification # / Exp. Date Inspector's Name 9/4 /Company Data Reviewed by Date Reviewed Copy to: Architect Structural Engineer Project Inspector DSA G Testing Engineers - U.S. Labs 7895 Convoy Court, Suite 18 San Diego, California 92111 Phohe: (858) 71 5-5800 Fax:(858)715-5810 a Testing Engineers - Inland Empire 41146 Elm Street, Suite A Murrieta, California 92562 Phone:(951)677-0366 Fax:(951)677-5761 •••.-•MiM CONSTRUCTION INSPECTION REPORT DSA File* DSA APPLICATION* Client P.O. # NTP# PROJECT* Project Location ^y VQ /* /*/ Building Permit # r>7^fc Cii'" /'• ^$y^5fs*j< L&wfc- _f£. * "* , /fal&/H&fL <£&&&**-( Plan File* ,-^< ,-,@"Tield Report [J Notice to Compty f CD Concrete D D ACITech Q D Welding D PI Ofhflr Documents Referenced \\ Q Sample Type: Soils Report PI Plans Date 5rr A Reinforcing Steel Masonry Bolting Waattior djGA/l- Q Specs. Date Date ^"Z. Time Arrived Time Departed OSHPD* |~| Pre-Post Tenstoned Tendon S^Soite Q Rreproofing PI RFI* Rnlibration Dates *^ j &G&7 13& 3&O Q Batch Plant O Foundations O Metal Decking F! Codes ^tf Ganetf ^"J^^Z. Amount Made/Taken: This Work DWas D Was Not Inspected, Tested, and Sampled in Accordance With Requirements of the DSA Approved Documents. The Work Inspected D Met D Did Not Meet the Requirements of the DSA Documents. The Work Tested DAW'ttl Did Not meet the Requirements of the DSA Documents. The Work Sampled D Met D DidNot meet the Requirements of the OSA Documents. CERTIFICATION OF COMPLIANCE: To the best of my knowledge, all of the observed work, unless otherwise stated, is in Conformance with the approved plans and specifications and the workmanship provisions of the Applicable code.Q+WD Did Not Meat Cc: Project Architect: Structural Engineer: Inspector of Record: Inspector's Signature DSA Regional Office: School District Certification # / Exp. Date Inspector's Name Approval signature / Name / Company Reviewed by Date Reviewed Copy to:Architect Structural Engineer Project Inspector DSA LEUCADIA WASTEWATER DISTRICT APPLICATION FOR SEWER SERVICE The application must be signed by the owner (or his representative) of the property to be served. The total charges must be paid to the District at the time the application is submitted. APPLICANT MUST SUBMIT EVIDENCE OF BUILDING PERMIT WITHIN 60 DAYS. FAILURE TO MAKE SUCH SUBMITTAL WILL RESULT IN AUTOMATIC CANCELLATION OF THE SEWER PERMIT. THE SEWER CAPACITY FEE LESS A $50 ADMINISTRATIVE FEE WILL BE REFUNDED. A six-month construction period shall be provided and sewer service charges for the balance of the fiscal year shall be collected at the time of application for sewer permits. Sewer service charges for subsequent fiscal years shall be collected on the tax roll in same manner as property taxes. If the six-month construction period extends into the subsequent fiscal year, a prorated sewer service charge for that fiscal year shall be collected for the balance of that fiscal year at the time the applicable capacity fees are paid. There will be no additional fee or refund if service actually commences on a different date. If a service lateral is required, it must be installed by the owner/applicant in conformance with the specifications, rules and regulations of the District and subject to inspection by the District. A DISTRICT INSPECTOR MUST BE ON THE SCENE AT THE TIME OF CONNECTION. The service lateral is that part of the sewer system that extends from the main collection line in the street (or easement) to the point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's building sewer. The applicant is also responsible for the construction, at the applicant's expense, of the building of sewer from the applicant's plumbing to the point in the street (or easement) where a connection is made to the service lateral and for construction, maintenance and connection of the service lateral to the main line. IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT. THE APPLICANT OR HIS AUTHORIZED REPRESENTATIVE MUST NOTIFY THE DISTRICT AT THE TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLECTION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED. ALL SUCH CONNECTIONS MUST BE MADE WITH AN LWD INSPECTOR AT THE SCENE AT THE TIME OF CONNECTION. IF, FOR ANY REASON, A CONNECTION IS IMPROPERLY MADE, IT SHALL BE THE RESPONSIBILITY OF THE APPLICANT, AT THE APPLICANT'S EXPENSE, TO DIG UP OR OTHERWISE RE-EXPOSE THE CONNECTION SO THAT AN INSPECTION MAY BE MADE AND THE APPLICANT, AT THE APPLICANT'S EXPENSE, SHALL MAKE ANY CORRECTIONS OR ALTERATIONS REQUIRED BY LWD. IN THE EVENT THAT THE APPLICANT, FOR ANY REASON, FAILS TO TAKE APPROPRIATE ACTION, THE DISTRICT RESERVES THE RIGHT TO DIG UP AND INSPECT THE CONNECTION AND MAKE ANY CORRECTIONS NECESSARY, AT THE APPLICANT'S EXPENSE: OR IN THE ALTERNATIVE, TO DISCONNECT SERVICE. ANY COSTS INCURRED BY LWD IN TAKING SUCH CORRECTIVE ACTION SHALL BE BILLED TO THE APPLICANT AND MAY BE RECORDED AS A LIEN AGAINST THE APPLICANT'S PROPERTY EQUAL IN PROIRITY TO A TAX LIEN. OWNER'S NAME Continuing Life Communities MAILING ADDRESS 1940 Levante Street PHONE NUMBER 704-6263 La Costa Glen 3/4 SERVICE ADDRESS 7835 Rush More Drive/ 1991 Lancewood Lane TRACT NAME/NO. LOT# ASSESSOR'S PARCEL NO. 255-012-1700 CONNECTION FEE: $ 236 . 263 . 40 PRORATED SEWER SERV. FEE $ 2 . 325 . 25 TOTAL S 238.588.65 TYPE/BUILDING Rest Home #/UNITS 71.90 PAID BY: QCASH HCHECK# £oV/ £o3$T ..-,..--- ^ The undersignejj^ereby ^agrees that the above information given is correct and agrees to the conditions as stated. 023389 "wner's Signature Date Rec'd by Account No. Received Resolution No. 1010 Initials City of Carlsbad » ' ^^^^^VWV^^^^^^V^H^^MI^^^^^^^HHBHBHHBuilding Department CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. CfMTAProject Name: Building Permit Plan Check Number: Project Address: A.P.N.: Project Applicant (Owner Name): Project Description: Building Type: Residential: Second Dwelling Unit: Square Feet of Living Area in Residential Additions: Net Square Feet New Area fiL$r\T; Dwellina 1 Square Feet of Living Area in Commercial/Industrial: City Certification of Applicant Information: Square Feet Floor Area ^J £~ 9 p Date: SCHOOL DISTRICTS WITHIN THECITY OF CARLSBAD Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 (331-5000) San Marcos Unified School District 215MataWay San Marcos, CA 92069 (290-2649) Contact "Nanny Pnlnr (By rtppt, Only) Encinitas Union School District 101 South Rancho Santa Fe Rd Encinitas, CA 92024 (944-4300 ext 166) San Dieguito Union High School District 710 Encinitas Blvd. .Encinitas, CA 92024 (753-6491) Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. Signature:Date: Revised 4/2 0/00 1635 Faraday Avenue • Building Counter Carlsbad, CA 92008-7314 • (760) 6O2-270O • (760) 602-2719 • FAX (76O) 602-8558 City of Carlsbad Building Department CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project Name: Building Permit Plan Check Number: Project Address: A.P.N.: Project Applicant (Owner Name): Project Description: Building Type: Residential: />> fa tfl CSS *— ^ Number of New Dwelling Units Square Feet of Living Area in New Dwelling Second Dwelling Unit: Square Feet of Living Area in SOU Residential Additions: Net Square Feet New Area Commercial/Industrial: Square Feet Floor Area City Certification of Applicant Information: Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 (331-5000) HOOL DISTRICTS WITHIN HE CITY OF CARLSBAD San Marcos Unified School District 215 Mata Way San Marcos, CA 92069 (290-2649) Contact: Nancy Dolce (By Appt. Only) utas Union Scfiool District 101 South Rancho Santa Fe Rd Encinitas, CA 92024 (944-4300 ext 166) San Dieguito Union High School District 710 Encinitas Blvd. Acinitas, CA 92024 (753-6491) Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described projects), or that the person executing this declaration is authorized to sign on behalf of the Owner. Signature:Date: 1635 Faraday Avenue • Carlsbad, CA 92008-7314 - (760) 602-270O Anniversary KTQY GROUP, INC. Architecture Planning 1T992 Mitchell South Irvine, California 92614 949/861-2133 FAX 949/851-5156 January 17, 2005 Mr. Mike Peterson City of Carlsbad 1635 Faraday Ave. Carlsbad, CA 92009 Re: La Costa Glen ILU Apartment D Project Number 2004032 Plan Check Numbers: As indicated below Mr. Peterson: Our client, Continuing Life Communities, has informed us that you require the gross and net areas of the buildings for the purpose of calculating school fees. The net areas exclude storage, mechanical/ electrical spaces and unconditioned exterior deck spaces. The breakdown of those areas is: CENTRAL PLANT £PC04-0105) CARPQRTS & GARAGES (PC04-0103) GROSS AREA Non-Qualifying Area Net Area GROSS AREA Non-Qualifying Area Net Area GROSS AREA Non-Quaiirying Area Net Area 113,675 s.f. 15,482 s.f 98,193 s.f. 8,056 s.f. 8,056 s.f. Os.f 12,841 s.f. 12,841 s.f. Os.f If you have any questions regarding foe calculations please do not hesitate to call. Sincerely: •mi uu.i cri.nn TOM nnn7_n7_MPO OCT-24-2COO 7UE 10=13 fl* CARLSBAD ENGINEERING FAX NO! 760 602 1052 ?. 15 WAIS Document Retrieval Page 1 of 7 CALIFORNIA CODES GOVERNMENT CODS S2CTIOU 65995-6S99B €5995. (a) Except foe a fet, charge, dedication, or other requirement authorised under Section 17630 oC the Education Cod*, or pursuant to Chapter 4.7 (cownencing with Section 6S37Q), a fee, charge, dedication, or othet requirement for the construction or reconstruction of school facilities may not be levied or imposed in connection with, cr rcade a condition of, any legislative oc ad5udicative act, or both, by any state or local agency involving, but not limited Co, the planning, use, or development of real property, or any change in governmental organization or reorganisation, AS defined in Section 56021 or 56073. (b) Except as provided in Sections 65995. S and 65995.7, the amount of any fees, charges, dedication*, or other retirements authorised under Section. 1*7620 o£ the Education Coda, or pursuant to Chapter 4.7 (commencing witn Section 65970), or both, nay not exceed the following: (1) In the case of residential construction, including the .location, installation, or occupancy of manufactured homes and mobilehonea, ont dollar and ninety-three cer.ts ($1.93} per square foot of assessable space. "Assessable space," Cor this purpoee, means all of the square footage within the perimeter of a residential structure, not including any carport, walkway, garage, overhang, patio, enclosed patio, detached accessory structure, or similar area. The amount of the square footage within the perimeter of « residential structure shali. be calculated by the building department of the cicy cr ccunty issuing the building permit, in accordance with the standard practice of that city or county in calculating structural perimeters. "Manufactured home" and "mabilehome" have ths meanings set forth in subdivision (£} cf Section 17625 of the Education erode. The application of any f?e, charge, dedication, or other £orm of requirement to the location, installation, or occupancy of manufactured hones and tnobilehomea is subjecc to Section 17 625 of the Education Cod*. (2) In che case of any commercial or industrial construction, thirty-one cents ($O.J1) per square foot cf chargeable covered and enclosed space. "Chargeable covered and enclosed space," for this purpose, means the covered. ac^ inclosed space determined to be within the perimeter of a commercial or industrial structure, not including any storage areae incidental to the principal use of the construction, garage, parking structure, unenclosed walkway, or utility or disposal area, jhe determination of the chargeable covered and ^enclosed ^pace within_the _pe_riittete_r ofn a jcomraercia.l or jnjurr.rial structure shall be made bv tite .building department of rhe city__or cpuiitv iasuing^he building permj.t^ in ^accordance with the building standards of that city or _co_uncy.. (3) *r~he~~amount of the limits set forth in paragraphs (1-) and (2; shall be increased in 2000, and every two years thereafter, according to the -adjustment for inflation set forth in the statewide cost indent for class B construction, as determined by th* State Allocation Board at irs Jaauary meeting, which increase shall be effective as of the date of that meeting. (c) (1) Notwithstanding any other provision of law, during the ter* of a contract entered into between a subdivider or builder and a school district, city, county, or city and ccunty, whether general t.. 09/20/2000 School District Fees San Dieguito Union High School District Contact: Mary Ann Phone: (760) 753-6491 Pricing: Commercial rate @ .18-1/2 cents per sq ft Encinitas Union School District Contact: Pat Sanchez Phone: (760) 944-4300 x 166 Pricing: Commercial rate @ .17 cents per sq ft