Loading...
HomeMy WebLinkAbout1995 OLIVINE CT; ; CB073093; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08-11-2009 · Residential Permit Permit No: CB073093 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: 08/11/2009 # Dwelling Units: Bedrooms: Project Title: Applicant: Building Inspection Request Line (760) 602-2725 1995 OLIVINE CT CBAD RESDNTL 2132921500 Sub Type: Lot#: $314,169.24 Construction Type: Reference #: SFD 40 VN CT 04-09 1 Structure Type: SFD 4 Bathrooms: 4 TRIESTE PL 2: PHS 8, 2745SF LV 639SF GAR/11 0SF DECK/138SF LOG/120SF PORCH/103SF PATIO Owner: Status: Applied: Entered By: Issued: Inspect Area: Orig PC#: Plan Check# ISSUED 12/13/2007 JMA Plan Approved: 08/11/2009 PC 06-35 PC 07-78 WARMINGTON HOMES 701 PALOMAR AIRPORT RD CARLSBAD CA 92011 WARMINGTON TRIESTE ASSOCIATES LP C/O WARMINGTON HOMES CALIFORNIA 3090 PULLMAN ST #A 931-4766 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (S61473) Fee $1,318.65 $0.00 $857.12 $0.00 ($68.57) $31-42 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $3,423.00 05/8 $126.00 $0.00 ?? COSTA MESA CA 92626 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (31 05540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee ( 4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees TOT AL PERMIT FEES $0.00 $160.00 $4,492.00 $3,618.63 $5,717.88 $0.00 $0.00 $0.00 $2,242.00 $0.00 $0.00 $259.00 $60.00 $74.00 $0.00 $0.00 $0.00 $0.00 $0.00 $171.00 $22,482.13 Total Fees: $22,482.13 Total Payments To Date: $22,482.13 Balance Due: $0.00 Inspector: Vk ~ FINAL APrROVAL Date: °' '.3 'Z4f t-0 Clearance: '",!:, ~ 2.S::: ~ 1 O NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively refe1Ted to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file lhe protest and any other required info11Tiation with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. . ra City of Carlsbad Bldg Inspection Request . . . . For: 03/24/201 0 Permit# CB073093 Inspector Assignment: MC Title: TRIESTE PL 2: PHS 8, 2745SF LV Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF PATIO Sub Type: SFO --- Type: RESDNTL Phone: 7608818240 Job Address: 1995 OLIVINE CT Suite: Lot: 40 Location: Inspector: ----- OWNER WARMINGTON TRIESTE ASSOCIATES LP Owner: WARMINGTON TRIESTE ASSOCIATES LP Remarks: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Requested By: KYLE ISBELL Entered By: CHRISTINE R --~ ~ 1i~, ~e,. ~A1> .. t 'FW~H Lr:,L,(,,, t"AQ$ I).! PUlG-C: • NPtJ.-H.E.tll.L4~ ?\ett-14 ~v Ji..T P..A~ D~ / Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 06-35 lns12ection History_ Date Description Act lnsp Comments 03/08/2010 39 Final Electrical AP MC EMR ONLY, OK TO RELEASE METER 03/05/2010 39 Final Electrical CA MC MOVE TO MONDAY 12/09/2009 17 Interior lath/Drywall PA MC DRYWALL ONLY 12/09/2009 1 B Exterior Lath/Drywall AP MC 12/09/2009 23 Gas/Test/Repairs AP MC 12/07/2009 B2 Drywall/Ext Lath/Gas Tesl NR MC PER CONTRACTOR AFTER STOP 11/30/2009 16 Insulation AP PY 11/24/2009 27 Shower Pan/Roman Tubs AP MC 11/24/2009 B4 Rough Combo AP MC MINOR PICK UP 11/23/2009 B4 Rough Combo CA MC PER CONTRACTOR AFTER STOP 11/09/2009 13 Shear Panels/HD's AP MC OK TO WRAP 10/19/2009 15 Roof/Reroof AP MC OK TO DRY IN & LOAD 09/03/2009 11 Ftg/Foundation/Piers AP MC RECEIVED SOILS. PT & FORM CERT. REPORTS City of Carlsbad Bldg Inspection Request For: 03/08/2010 Permit# CB073093 Inspector Assignment: MC Title: TRIESTE PL 2: PHS 8, 2745SF LV Description: 639SF GAR/110SF DECK/138SF LOG/120SF PORCH/103SF PATIO Sub Type: SFD --- Type: RESDNTL Phone: 7608818240 Job Address: 1995 OLIVINE CT Suite: Lot: 40 Location: Inspector: f,4 6 _..,:._ __ _ OWNER WARMINGTON TRIESTE ASSOCIATES L P Owner: WARMINGTON TRIESTE ASSOCIATES L P Remarks: Total Time: CD Description 39 Final Electrical Requested By: KYLE Entered By: JANEAN Act Comments ~ ~-ifL ~~1>.e. --tb :tz,c: ~~ Mc,-n,SL., Comments/Notices/Holds Associated PCRs/CVs Original PC# PC 06-35 lnsg;ection Histo[Y Date Descrlption Act lnsp Comments 03/05/2010 39 Final Electrical CA MC MOVE TO MONDAY 12/09/2009 17 Interior Lath/Drywall PA MC DRYWALL ONLY 12/09/2009 18 Exterior Lath/Drywall AP MC 12/09/2009 23 Gas/Test/Repairs AP MC 12/07/2009 82 Drywall/Ext Lath/Gas Test NR MC PER CONTRACTOR AFTER STOP 11/30/2009 16 Insulation AP PY 11/24/2009 27 Shower Pan/Roman Tubs AP MC 11/24/2009 84 Rough Combo AP MC MINOR PICK UP 11/23/2009 84 Rough Combo CA MC PER CONTRACTOR AFTER STOP 11/09/2009 13 Shear Panels/HD's AP MC OK TO WRAP 10/19/2009 1 5 Roof/Reroof AP MC OK TO DRY IN & LOAD 09/03/2009 11 Ftg/Foundation/Piers AP MC RECEIVED SOILS, PT & FORM CERT. REPORTS 09/03/2009 12 Steel/Bond Beam AP MC 09/03/2009 21 Underground/Under Floor AP MC 09/03/2009 31 Underground/Conduit-Wiring AP MC UFER OK 09/03/2009 98 BMP Inspection PA MC ON GOING 08/25/2009 21 Underground/Under Floor AP MC 08/25/2009 22 Sewer/Water Service AP MC <;.r .. ,t. " lt .. :111\t,. :!\i{' Southern California Soil and Testing, Inc . . sic 6280 Riverdale Street, San Diego, CA 92120 (619) 280-4321 S ~l P.O. Box 600627, San Diego, CA 92160-0627 ~ 83-740 Citrus Avenue, Suite G, Indio, CA 92201-3438 (760)775-5983 Concrete (4x8) Compressive Strength Test Report File Number: 0612215 Project Title: Trieste at La Costa Greens PTCC Phase: 8 Project Location: Ollvine Col.l't Architect: Engineer: William Hezmalhalch Martin Permit No: Contractor: Warmington Homes Plan File No: Location In Structure: Lot: 40 Northwest Corner of Slab Material Supplier: Superior Mix Designation: 375p Admixture(s): Pouolan Time In Mixer: Air Content: (ASTM C173/C231) Air Temp: Truck Number: Samples Made By: (ASTM C31) Laboratory Number Mark On Samples Date Made Date Received Date Tested Diameter, Inches Area. Square Inches Maximum Load, Pounds Compressive Strength, psi Age Tested Required 28 Day Strength, psi Fracture Type 50 minutes 77 degrees F 653 JG 0990219 40 9/4/2009 9/8/2009 9/9/2009 4.00 12.57 51,260 4080 5 Days 4500 Slump inches: (ASTM C143) Unit Weight Plastic/Dry, pcf: (ASTM C138/C567) Concrete Temp: (ASTM C1064) Ticket Number: Samples Tested By: 0990220 0990221 9/4/2009 9/4/2009 9/8/2009 9/8/2009 10/2/2009 10/2/2009 4.00 4.00 12.57 12.57 77,750 73,970 6190 5880 28 Days 28 Days 4500 4500 1 2 5.00 I 88 degrees F 156144 CN Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM C39 standards. This agency makes no other warranties express or implied. Fracture Type: 1 -Reasonably well formed cones on both ends, less than 1 in. of cracking through caps; 2 -Well formed cone on one end. vertical cracks running through caps.no well defined cone on other end; 3 -Columnar vertical cracking through both ends, no well formed cones; 4 -Diagonal fracture with no cracking through ends; 5 -Side fracture at top or bottom (occur commonly with unbonded caps); 6 -Similar to type 5 but end of cylinder is pointed. Distribution: Reviewed By: (1) City of Carlsbad -Building Inspection Department (1) Warmington Homes California Gordon T.M. Wood rd RCE # 60481 PLANNING lNGINEfRING SU~VtYING 11<\IINf: LOS 1\NCELES RIVEl!SIDE Si\N l)lff,fl i\RIZON/\ 1)1\VE 1-il\MM/\R 1.LX WILI.IM/\N /\LIS/\ Vl1\Ll'ANIJO DAN SMITH IMY MAl<TIN CHUCKC/\Trn !)707 W.1plcs S1rel,I S,,,, D,v~o. CA 92121 ll\5ill 5511-4500 PH (851\) 558-1414 F X www.Huns.1kerSO.com I nfo@H unsaker SD .con, HUNSAKER &ASSOCIATES S 1\ N U I I: C 0, ! N ( August 24, 2009 City of Carlsbad Engineering Department 1635 Faraday Avenue Carlsbad, CA 92008-7314 Re: Building Form Certification La Costa Greens Neighborhood 1.17 Carlsbad Tract 04-09/PUD 04-08A Drawing No. 429-2C Lots 35 through 44 Dear City Inspector: Please be advised the building foundation forms are in conformance with the precise grading plans as to horizontal and vertical location. All locations checked were found to be within 0 1 of a foot horizontally and vertically per the precise grading plans Sincerely, D~LS6854 Hunsaker & Associates San Diego, Inc. 0$ kc k.,Ql07\2009\d35 dQCX WO 0107-268 ,8/2412009 2.11 PM ,, GEOCON I N CORPO RA T ,E D 6960 FLANDERS DRIVE -; c~ GEOTECHNICAL CONSULT ANTS IEGO, CALIFORNIA 92121-297 4 • TEL {8581 558-6900 • FAX {8581 558-6159 ~ FOUNDATION OBSERVATION REPORT PROJECT NAME : ::Tb~ G,~<::v,S Wo, ...... ~,JI) ... 1 ,3 LOCATION : Loi. S ~ '\ · 4? PROJECT NO. (;,Yo'? -5 2. 2.t,., DATE : 112./0C, FOUNDATION LOCATION (if not entire building)--------------------------- PLAN FILE NO. PERMIT NOS : LoT-5 J<\ -(11o~"'0r1-, ~ ~ , . ...,.., D ADDITIONAL OBSERVATION REQUIRED FOUNDATION TYPE : ~-. "'iO • D CONVENTIONAL '-\ t. "ii -¢ SUBSTANTIAL CONFORMANCE 17._ POST· TENSIONED • PURPOSE OF OBSERVATION m-Verify soil conditions exposed are similar to those anticipated D Verify footing excavations extend to minimum depth recommended in soil report D Verify foundation reinforcement complies with minimum recommended in soil report D Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report ~ Verify footings have been extended to an appropriate bearing strata D Other ---------------------------------------- • APPLICABLE SOIL REPORT: TITLE : t -~ \ G ... J -cA,., f?p ~,i \J', I ,,, <"',+. -n, .. , G ✓~ ... ~ \J .. \ DA TE : "f /I u/rt,, • SOIL REPORT RECOMMENDATIONS BASED ON : 0 Expansion Condition O VERY LOW O LOW O MEDIUM D HIGH O VERY HIGH D Fill Geometry ------------------------------------- □ Otper : --------------------------------------- • MINIMUM FOUNDATION RECOMMENDATIONS : ( ._-\ 1f -23' fl, ~ Lt O c .:.T l[:_ 2 <, U. \ r '-h □ Footing Depth : 0 12 Inches O 18 Inches D ·24 Inches . OTHER _____________ _ Footing Reinforcement: D No.4 T&B D 2-No.4 T&B D 2-No.5 T&B. D Post-Tensioned OTHER : _____ _ Interior s·lab Reinforcement : D 6x6-10/10 D 6x6-6/6 D No.3@24Inches D No.3@18Inches D Post-Tensioned Slab Bedding Material and Thickness : ~;"•· \ Vapor Barrier : ~v_·,"""°'}------- Foundation Width : __....~"""-'-------------------------------- • OBSERVATIONS : D Substantial conformance with Soil Reports (see ·"Purpose of Observation") r;;/ Substantial conformance with Foundation Plans, Identify : --------------------- 0 Other _______________________________________ _ • COMMENTS : 1!.o'•l.) O 'r, o 1 1°1 Yo -~ \. ,··~OJ.1 'o-1, •• ~, ov--" t;'lo~ o""' \.1 ,• (0<,t ~ < ,.!· w-0,,t,, t ,_JJ ._.:_1 P"'', I -....,.,)._! ... I y ~-' ·--~, kf'< ... I (Ml ~J, -t,, r o""crr~ ~Oc..t/ }('. ~IT t_S ASSUMED THAT All FOOTING EXCAVATIONS Will BE CLEANED OF LOOSE MATERIAL PRIOR TO PLAONG CONCRETE AND THAT THE SOil MOISTURE CONTENT WILL BE MAINTAINED AELD COPIES TO ON REPRESENTATIVE DSAAPP. NO,:' PIAN Fl E1NO.: ·SUB C:ON~. OR, , -.L .... , '' ' ' L,/,(1.f//C~;,(• m Chi of C1rl1bld m Rnal Bulldlnu lnspacdon Dept: Buildi Plan Check #: Permit#: Project Name: Address: Contact Person: Sewer Dist: CB073093 g Planning CMWD St Lite Fire Date: TRIESTE PL 2: PHS 8, 2745SF LV Sub Type: 639SF GAR/11 0SF DECK/138SF LOG/120S F PORCH/103 1995 OLIVINE CT Lot: 40 Phone: LC Water Dist: CA .......................................................................................................................................................... Inspected . A Date ~~zfto By: (2 fE:..At-Ds. Inspected: Approved: Disapproved: r- Inspected A Date ~l~ By: ~ Inspected: Approved: .,,,,..,,.., Disapproved: __ 7' ~ Inspected Date By: Inspected: Approved: Disapproved: __ ··························································································································································· Comments: ______________________________ _