Loading...
HomeMy WebLinkAbout2001 Arenal Rd; ; CBC2018-0094; Permit(city of Carlsbad Commercial Permit Print Date: 02/27/2018 Permit No: CBC2018-0094 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2001 Arena1 Rd BLDG-Commercial $0.00 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check#: Description: TIME WARNER: NEW 100A METER PEDESTAL Applicant: OANG LEE 12681 Pala Dr Garden Grove, CA 92841-3926 714-897-6300 PLUMBING, ELECTRICAL, AND MECHANICAL PERMIT Total Fees: $170.00 Total Payments To Date: P/M/E $170.00 Status: Applied: Issued: Permit Finaled: Inspector: Final Inspection: Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES ff APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Closed -Finaled 02/16/2018 02/20/2018 MColl 2/27/2018 11:07:56AM $170.00 $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov · (cicyof Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 78CMI02-2719 Fax: 760-602-8558 email: bulldlng@carlsbadca.gov www.carlsbadca.gov Plan Check No.Gg)C,c() 18° -Qffi ~ Est. Value Plan Ck. Deposit Date -2.D- SUITE#/SPACE#/UNIT# APN # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE CCC. GROUP EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS {SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS YESD # __ NOD YES O NOD YES D NOD Ci zq;tff tf/ ADDRESS CITY STATE ZIP PHONE FAX EMAIL STATE UC.# PROPERTY OWNER NAME ~c ADDRESS CITY PHONE EMAIL STATE ZIP ZIP qz.t Z, __ --j (Sec, 7031.5 Business and P_rofessions Code: Any City or County which requires a permit to_construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a sii;!ned statement that he is licensed pursuant to the prov1s1ons of the Contractor's License Law /Cha'/'ter 9, commending with Section 7000 of D1v1s1on 3 of the Business and Professions Code} or that he 1s exem_P.t therefrom, and the basis for the alleged exemption. Any v1olat1on of Section 103 .5 by any applicant for a permit subJects the applicant to a civil penalty of not more than five hundred dollars {$500}). WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of peryury one of the following declarations: LI I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co Policy No. Expiration Date __________ _ This section need not be completed if the permit is for one hundred dollars ($100) or less LI Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up lo one hundred thousand dollars (&100,000). in addition to the cost of compensation, damages as provided for in Section 3706 of lhe Labor code, interest and attorney's fees . .Ji$ CONTRACTOR SIGNATURE 0AGENT DATE OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) Cl I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section ______ Business and Professions Code for this reason 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement D Yes D No 2. I (have I have not) signed an application for a building permit for the proposed work 3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone f contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address f phone I contractors' license number) 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work): ,A$ PROPERTY OWNER SIGNATURE 0AGENT DATE ,COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES ANO THE AIR POLLUTION CONTROL DISTRICT. I certify that I have read the application and state that the above infonnation is correct and that the infonnation on the plans is accurate. I agree to oomplywith all City ordinances and State laws relating to bulldlngoonsbuction. I hereby authorize representative of the City of Carlsbad to enterupoo the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABIUrlES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMrT. OSHA: M OSHA permit is required for excavations over 5'0' deep and derrdition or construction of struciures over 3 stories in hffi'Jhl EXPIRATION: Every permit issued by the Building Official under lhe provisions of this Code shall expire · ital.ion and become null and void if the building or work authorized by such permit is notoommenced within 180 days from the date of such pennit or if the building or authorized by such pennlt is sus or abandoned al any time after the work is commenced for a period of 180 s (Section 106.4.4 Uniform Building Code). AS APPLICANT'S SIGNATURE DATE Permit Type: Work Class: Status: Scheduled Date BLDG-Commercial P/M/E Closed -Finaled Actual Start Date Inspection Type 02127/2018 02/27/2018 BLDG-34 Rough Electrical Application Date: 02/16/2018 Issue Data: 02/20/2018 Expiration Date: 08/27/2018 IVR Number: 9592 Inspection No. Inspection Status 049923-2018 Passed Checklist ltcm COMMENTS Owner: Subdivision: Address: 2001 Arena! Rd Carlsbad, CA Primary Inspector Re inspection Complete -·--·----·---·--------- Michael Collins Complete Passed BLDG-Building Deficiency 100 amp pedestal with driven ground Yes February 27, 2018 BLDG-Final Inspection 049924-2018 Checklist Item BLDG-Building Deficiency BLDG-Electrical Final Passed COMMENTS EMR emailed to SDGE Michael Collins Passed Yes Yes Complete Page 1 of 1 ELECTRIC UNDERGROUND METER & SERVICE LOCATION A ~-Sen1pra E_nergy.ulil_lty"' Customer Copy Notification#: 300000103846 Job#: I TB: 1127-F7 Wanted Date: ON INSPECTION Date Prepared: 07/20/2016 Customer Type: Commercial Service Type: UG SERVICE NEW Project TIiie: TWC, 2001 ARENAL RD MP NEW Project Address: 2001 ARENAL RD I Project City: CARLSBAD Addltional Address Info: Customer POC: CARLOS LOPEZ Customer Phone #: 858-695-3220 SDGE Contact: Operations Assistant Contact Info: , 760-432-5805 I Traffic Control Permit Required [ZjSDG&E Application Required-Call: 1-S00-411_-7343 Excavation/Encroachment Permits Required By: Customer Munlclpal Inspection required By: CITY OF CARLSBAD I Temp Service Charge due on First Bill$ 0.00 SERVICE ATTACHMENT POINT AND/OR METER LOCATION: Customer Is to locate new 1 OOAMP meter pedestal 20 feet west of 03398268949. Face pedestal toward street and maintain 3ft x 3ft dearance. Customer Is to provide trench, backfill, surface repair, and compaction, pull tape and 3 inch conduit from D3398268949 to new meter pedestal. Address must be permanently marked on meter pedestal. See Specs 692-692-1. Customer Is to obtain a permit and inspection from the City of Carlsbad. Contact SDG&E at 760-432-5805 to set up a pre-meet prior to excavating. Station ID#: 755-160 Structure #: D3398268949 I Joint Trench With: Handhole Installed By: Handhole Lid Shall Read: Standards Page: Ladder Arms: I Stop Trench: from Pole Riser Quad: Bend Installed By: SDG&E I Bend Type: TRANSFORMER Bend Info: 3" 90 DEG 36"R DB60 Conduit Installed By: CUSTOMER Conduit Size: 3" Service Panel Rating: 100 Number/Size of Main Switch: 1@100 I Voltage: 120/240 # of Wires: 3 Phase: 1 Utililies Maximum Contrlbullon to Fault Current: 42000 Metering: Self Contained. Test Bypass Facilities Reqd Meter Clips: 4 Meter height --4'0" min. (3'0" min. for multiple lnstallatfon) --6'3" max. From finish grade to centerline of meter base. Meters are required to be readily accesslble 24 hours per day. Meters must be located In a safe area free of any potentlally hazardous or dangerous condition. Provide 3-ft. x 3-ft. clear and level working space in front of meter. \Nhere meter room Is proposed, contact the planner at the nearest SDG&E office. Meter bases and meter .service disconnects must be located at or Immediately adjacent to each olher and be Identified with address and unit number. PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT "811" AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILITIES. 2. Phone Operations Assistant at 760-432-5805 for the following: - 3 Working days prior to trenching to arrange pre-meet with Inspector and initiate trenching process. -After excavation of trench, Installation of conduit and service entrance equipment at meter location, CALL FOR INSPECTION. Do not cover conduit without Inspector's written approval to backfill. -When trench is backfilled and compacted, CALL FOR INSPECTION. -If service entrance equipment Is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT. 3. Meter cannot be set until Inspector has approved Installation, Jncludlng service equipment, and receipt of city/county/state inspection Additional Information: l_ylghl of Way Required Assessor's Parcel Number: Please call your Operations Assistant at 760-432-5805 with questions about application, inspection, construction installation and to schedule a crew. If SDG&E encounters hazardous or toxic material whlle performing construction of your project, SDG&E will halt work immediately and It will be your responsibility to remove and or clean up all hazardous or toxic material prior to SDG&E continuing construction. SDG&E shall have no liablllty or obligation whatsoever to cleanup, remove or remediate any hazardous or toxic materlals discovered during the course of construction unless lt Is through negligence of SDG&E. Customer-owned facllltles to receive gas service are subject to all applicable local and state of CaHfornla inspectfon authority requirements. Building address and/or houseline must be permanently identified prior to meter set. Information on this sheet is void after six (6) months. Keep this noUce with butldlng permit. Planned By: Jessica Mims Phone#:6586365713 Job Notification # 300000103846 Planner Name: Jessica Mims Customer Name: TWC/CARLOS LOPEZ P/G 1127 F7 ' ' ' I METER AND SERVICE LOCATION: ~··· -· r·-·3""' CONDUIT Date: 7/20/2016 Planner Phone: 858-636-5713 Customer Phone: 760-497-9289 CUSTOMER TO INSTALL NEW 100AMP METER PEDETAL WITHIN 2Q,FT WEST OF D339268949. Call Btt: Tit'() ',',b·/cfog Do.)l:!I Before Yo11 Oig! t N I L 11 s!l§( :. -~ Sentpra tne--rgy ..a:-:.r