Loading...
HomeMy WebLinkAbout2001 CORDOBA PL; ; PCR09105; Permit01-13-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plan Check Revision Permit No:PCR09105 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: PC#: Project Title: 2001 CORDOBA PL CBAD PCR 2072401400 Lot#: $0.00 Construction Type: CB090648 PURNEL RES-UPDATE ELECT PANEL FROM 100 AMP TO 400 AMP 0 NEW Applicant: RAY PURNEL 68-393 MOONLIGHT DR CATHEDRAL CITY 92234 7602503153 Status: ISSUED Applied: 08/06/2009 Entered By: LSM Plan Approved: 08/07/2009 Issued: 08/07/2009 Inspect Area: Owner: PURNEL RAYMOND&ANDERSON LYNDA 2001 CORDOBA PL CARLSBAD CA 92008 Plan Check Revision Fee Additional Fees $105.00 $0.00 Total Fees:$105.00 Total Payments To Date:$105.00 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which YOU have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. «r <*. CITY OF CARLSBAD PLAN CHECK REVISION APPLICATION B-15 Development Services Building Department 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov Plan Check Revision No. Project Address 2°o> gog.ooe>A PtAeg Contact Original Plan Check No. Date Contact Address 68" 0*73 MOOMUfcHT PE1V6 General Scope of Work City<?A7>tePftrt«- C»1V Zip ertAVPE Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person. 1 Elements revised: Calculations Q Soils D Energy G OtherPlans ,.-,«!#* 2 Describe revisions in detail WJ/TH A- 44)6 AMp P/WEL. . 3 '' UNOERGfediW*7 sewv* PEEP n^/»t srfteer UTIL.-H VAULT- V 3 List page(s) where each revision is shown 4 List revised sheets that replace existing sheets 5 Does this revision, in any way, alter the exterior of the project? O Does this revision add ANY new floor area(s)? Q Yes T Does this revision affect any fire related issues? HH Yes 8 Is this a complete set? [y Yes [H No ^Signature- Yes 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-2717/2718/2719 www.carlsbadca.gov Fax: 760-602-8558 City of Carlsbad BUILDING DEPARTMENT 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: 760-602-7541 / Fax: 760-6024558 Plan Chech Comments / 2OO7 Codes From: Steve Borossay Pages:\ Phone:Date: &Jlfo<*> o G CONTACT HOURS FOR STEVE BOROSSAY: TUESDAY THROUGH FRIDAY: 1PM - 5PM *** Please make corrections referred to below and run TWO new prints. If red marks are on plans as a part of this Plan Check response please return red marked set with the new prints. * This is a BUILDING REVIEW ONLY. Comments or approval do not apply to any other City department review. For information on the status of approval from other departments please contact staff @760-«02-271 7/2718/2719. § ~-o CO epp I /O is 0 UAJ 0 / A T Concrete Encased Electrode (Rebar) 2007 California Electrical Code Article 250.52(A)(3) Published: May 1980. Revised: July 2005 The NEC makes it clear that underground metal water pipei can no longer be relied upon to assure a permanent and effective ground. To this end, several different grounding electrodes are identified as acceptable alternatives to the water pipe. The two most commonly used are the ground rod and the concrete encased electrode. The use ofgTduhd rods and concrete encased electrodes has raised questions. The intent of this newsletter is to identify the minimum requirements for an acceptable concrete encased electrode constructed of reinforcing steel (rebar), commonly called a "ufer" ground. These minimum requirements are as follows: •c=?f 1. The #4(1/2") or larger rebar to which the grounding electrode conductor is connected must be a minimum of 20 feet long, unbroken. 2. The total developed length of rebar at the bottom of the foundation must be no less than 20 feet. Where splices are necessary to obtain the required 20 feet of rebar, they must be made so that the two bars overlap by no less than 15 inches and are secured by at least two steel tie wires. 3. The rebar may only extend out of the slab in a dry location. 4. The rebar must extend out of the slab at least six inches and no more than 18 inches and the point of connection of the grounding electrode connector must be accessible. Exception: Where the connection of the grounding electrode conductor is encased in concrete and the connector is listed for concrete encasement. THE #4 (1/2") REBAR EXTENING OUT OF THE SLAB MUST BE A MINIMUM OF 20' LONG, UNBROKEN 2" MIN. 4" MAX.~L T MINIMUM OVERLAP 15-1 20'• FOOTING OR FOUNDATION MINIMUM DEVELOPED LENGTH January 2008 San Diego Area Electrical Newsletters 20 ioe OP 4-00 Amf loo A»vif» -400 Aw\f T, |?<H_e MAiu E>iz.eAi^trt_ , I C. To >feafc-0 w<MOfL-, CySLO^MO P-OO w iTrt IN/ S-o'1 OF iawice 4 TO 2OO 70 4/0 P I- POL£ 50 AMP 2. foi_e 5-0 AMf 2. Poi_e 30 Z POLJ5 "A"ZOO ZO 20 2-0 Arvi P 2-0 I POLE - P&LE - Electrical Load Calculation - Residential Project: 2001 Cordoba PI, Carlsbad CA Plan Type: Computed Load (Article 220) 2020 General lighting load @ 3 watts per square foot 4 Small appliance load @ 1500 watts each 1 Laundry load @ 1500 watts each Total general lighting and small Demand Factor (Table 220-11) First 3000 watts or less @ 100% appliance load From 3001 to 120,000 watts @ 35% Remainder over 120,000 watts @ 25% Net general lighting and small appliance load Fixed Appliance Load (Article 220-17) 1 Refrigerator 1 Dishwasher 1 Oven-Microwave 40 amp 240 volt 1 Disposal 1 Hood 1 Insta hot water dispenser Watts per 1650 1440 9600 900 600 780 Total Demand Factor 75% Total with demand factor Other Loads 1 A/C compressor 22.7 amps, 240v 1 Spa - 40 amps 230v 1 Furnace 1 Dryer 1 Range (future) 1 RV connection 30 amp 125v 1 RV Connection 50 amp 125v Watts per 5221 9200 1440 5000 10,000 3750 6259 6,060 6,000 1,500 13,560 3,000 3,696 0 6,696 1,650 1,440 9,600 900 600 780 14,970 11,228 5,221 9,200 1,440 5,000 10,000 6,250 Requires 4flQ Amp Service Total other loads 37,111 Total Load 68,595 Watts 68,595 Watts / 240 Volts = 286 Amps SOGJ ELECTRIC UNDERGROUND ulETER & SERVICE LOCATION Customer Copy Sempra Energy ui«y' Wanted Date: ON TRENCH INSPECTION Project Address: 2001 CORDOBA PL Project City: CARLSBAD Contact CINDY ANDERSON Customer Phone ft 760-238-7970 Contact Phone ft 760-238-7970 Service Type: UG Service Rewire/Relocation Project No: 955750 Job No: 010 Protect Tide: ANDERSON. DAVID (SOT-NP) I Traffic Control Permit Required. Excavation/Encroachment Permits Required By Customer Service Attachment Point and/or Meter Location: Customer is responsible for 8 SDG&E approved 400 amp residential meter panel, with a Class 320 plug-in meter socket Customer to provide all excavation, trench, 3" conduit, backfill, compaction, 3/4" pulling and measuring tape in conduit and surface repair from the existing handhole to new meter panel. The panel shall be marked with either a rating of "320 Amperes Continuous" or "400 Amperes Maximum (320 Amperes Continuous)". Please see Service Guide 611 for specific clearances. SDG&E Application Required - Cad: Municipal Inspection Required By City of Carlsbad Meter height -W mfo. -6T max. From finish grade to conteriine of meter base. Meters are required to be readty accessible 24 hours per day. Meters must be located in a safe area free of any potentialy hazardous or dangerous condition. Provide 3-fl. X 3-ft Minimum dear and level working space In front of meter. Where meter room is proposed, contact the planner at the nearer! SDG&E office. Meter bases and meter service disconnects must be located at or immediately adjacent to each other and be identified with address and unit number K serves. PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT 1-800-227-2600 AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTILITIES. 2. Phone SDG&E at 760-476-5611 for the following: • 3 working days prior to trenching to arrange pre-meet with inspector and initiate trenching process. • After excavation of trench, instalation of conduit and service entrance equipment at meter location, CALL FOR INSPECTION. Do not cover conduit without inspector's written approval to backfil. • When t/em* is badrfilted and compacted, CALL FOR INSPECTION. • If service entrance equipment is installed after DackfM, CALL FOR INSPECTION OF THE EQUIPMENT. 3. Meter cannot be set until inspector has approved installation, including service equipment, and receipt of ctty/countyAlate inspection clearance. Power Source: 303-297 Structure Number EXISTING HANDHOLE Joint Trench with:Handhole Instated by. Standards Page *Handhole Lid Shan Read: Ladder Arms:Stop Trench:from pole Riser Quad: Bend Installed by: SDG&E Type: Handhole 3" 90 Peg 36"R DB60 Conduit Installed by Customer Conduit Size: 1-DBS- Service Panel Rating: 400 Number/Size of Main Switch: 1 @ 400 AMPS Voltage: 120/240 # of Wires: 3 Phase: Single Utilities Maximum Contribution to Fault Current 22000 Amps Metering: Self-Contained Meter Clips: 4 Temp Service Charge Due on First BB $ T.B. 1106-J7 Customer Type: Residential Date Prepared: 07/22/2009 Additional Information: Q Right-of-way Required Assessor's Parcel Number: Please caH your Service Coordinator Wendy Jensen at 760-476-5611 with questions about application, Inspection, construction instalation and to schedule a crew. To minimize the electrical outage, you are advised to schedule a morning disconnect with an afternoon reconnect There is no charge for this service. Before you change out your meter consider (1) SDG&E needs 5 working days advance notice to schedule a crew and (2) SOG&E will not reconnect the service without municipal approval on the new panel. Please contact the City/County regarding permits and inspections. » SDGiE «wwnln hrardou or toxic nuMrM «Mi perfuming omtucfcm of your proJKt SDG&E«« Monti ImnwdM^xd I ««b« your raponttatytoraiinwndfcrdMnuprirwifdouiortoJdcii^^ SDG«EtfulhMr»U>%oroUg«lfon •Mnmr to dun up, ramow or remed* any haantoin or toxic iraM* dhcownd during •» owMofcomtudlonunltuitiitmugpirMglgMictof 3DGSE. Cuttonw-oimdlicMMtanMiwilKMalMnlnira wb|Ktto rf w>lcil>ltlocilinlib*o<Cd<Dmi«ln<p««xi«it»rttyrK|uHiTitn^ BuMng •MrananMrmefebiMmurfbtpofMprlortomifcrMt MgmullononMiriiMttevold tfkribp) months tan d*. KMpWtnollntiWibuWng Planner KIM MAGEO Telephone: 760-476-5612 PCR09105 2001 CORDOBA PL PURNEL RES-UPDATE ELECT -v- Approved Building Planning Engineering HazMat Health Sate Forms/Fees FOG HazMal/APCD Health PE&M Comments Building Planning Engineering Fire Xtlcn Need? Application Complete? Y N Fees Complete? Y N