Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2002 PALOMAR AIRPORT RD; ; CB070727; Permit
City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09-09-2015 Commercial/Industrial Permit Permit No: CB070727 Building Inspection Request Line (760) 602-2725 Job Address: 2002 PALOMAR AIRPORT RD CBAD Permit Type: COMMIND Sub Type: INDUST Status: ISSUED Parcel No: 7602216000 Lot #: 0 Applied: 02/27/2007 Valuation: $185610.00 Construction Type: VN Entered By: KG Occupancy Group: Reference # Plan Approved: 06/26/2007 Issued: 06/26/2007 Inspect Area PD Plan Check #: PC070019 Project Title: MAGELLAN AVIATION BLDG 'E" 5472 SF HANGAR, Applicant: Owner: ANDERSON HOWARD COUNTY OF SAN DIEGO/PALOMAR AIRPORT 2194 CARMEL VALLEY RD DEL MAR CA 92014 . PUBLIC AGENCY 00000 858-755-5009 Building Permit $811.44 Meter Size Add'l Building Permit Fee $0.00 Add] Red. Water Con. Fee $0.00 Plan Check $527.44 Meter Fee $0.00 AddI Building Permit Fee $0.00 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $38.98 PFF (3105540) $3,378.10 Park Fee $2,921.60 PFF (4305540) $3,118.25 LFM Fee $0.00 License Tax (3104193) $0.00 Bridge Fee $0.00 License Tax (4304193) $0.00 BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $140.40 BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $129.60 Renewal Fee $0.00 PLUMBING TOTAL $62.00 Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $110.00 Other Building Fee $0.00 MECHANICAL TOTAL $0.00 Pot. Water ConFee $0.00 Master Drainage Fee $0.00 Meter Size Sewer Fee $501.38 Addl Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00 Red. Water Con. Fee $0.00 Additional Fees $0.00 Green Bldg Stands (5B1473) Fee ?? HMP Fee $0.00 Fire Expedidted Plan Review ?? Green Bldg Standards Plan Chk ?? TOTAL PERMIT FEES $11,739.19 Total Fees: $11,739.19 Total Payments To Date: $11,739.19 Balance Due: $0.00 Inspector: FINAL APPROVAL Date: 91 Clearance: NOTICE: Please take NOTICE that approval of your project includes the"Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as fees/exactions. You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your rlght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any Inspection List Permit#: CB070727 Type: COMMIND INDUST MAGELLAN AVIATION BLDG "E' 5472 SF HANGAR, Date Inspection Item Inspector Act Comments 03/05/2009 19 Final Structural TP PA TIM IS WAITING ON SPECIAL INSP. REPORTS 01/26/2009 89 Final Combo TP CO NEED STRUCT PLANS & Si REPORT 09/03/2008 89 Final Combo TP AP 08/26/2008 89 Final Combo TP NR 08/12/2008 89 Final Combo TP CO 08/12/2008 89 Final Combo TP CO 07/28/2008 89 Final Combo CO NOTICE ATTACHED 03/11/2008 17 Interior Lath/Drywall TP AP F. CAULK @ CLMNS 03/05/2008 17 Interior Lath/Drywall TP NR N/COMP. F/CAULK @ CLMNS 02/26/2008 17 Interior Lath/Drywall TP AP 2ND LAYER FOR RATED WALL 02/11/2008 14 Frame/Steel/BoltinglWeldin TP AP 1HR WALL INFILL 02/11/2008 17 Interior Lath/Drywall TP AP SHAFT WALLBOARD IN 1 H WALL 02/08/2008 17 Interior Lath/Drywall TP NR CORR N/COMP. 02/06/2008 17 Interior Lath/Drywall TP CO 01/15/2008 31 Underground/Conduit-Wirin JM PA CONDUIT ONLY TO HANGAR 11/14/2007 11 Ftg/Foundation/Piers JM AP OK TO POUR W/FORM CERT FROM SURVEYOR - LIFER OK 10/31/2007 ii Ftg/Foundation/Piers TP NR N/COMP. 10/31/2007 12 Steel/Bond Beam TP NR 09/27/2007 21 Underground/Under Floor TP CO 4" WATSE WITH C/O SPEC 09/17/2007 21 Underground/Under Floor TP AP SEWER MAIN TO BLDG 09/17/2007 22 Sewer/Water Service TP AP Tuesday, September 30, 2014 Page 1 of 1 Special Inspector's Final Report Project Name: //'/ //V477'/ '44// Permit Number: 6 070?2 '7 Project Address: cM'4 %..yot4'city Insp. Name: Special Inspector's Certification of Compliance TO THE BUILDING OFFICIAL: I hereby certify that the following portions of the work at the above address which required continuous inspection, and which I was employed to inspect, were inspected by me and comply with the provisions of the Building Code applicable thereto and were based upon approved plans, specifications, and the applicable workmanship provisions of the California Building Code. TYPE OF INSPECTION: Slump/cylinders t Rebar Placement Cl Tendon Placement 9 Welding/Structural Steel LI Concrete Placement' U Shot Crete I High-Strength Bolts ' U Precast/Post Tensioned Concrete U Masonry U Spray-Applied/Fire Proofing U Nondestructive Testing (NDT) U Other 0 Off site Fabricator (if any): Description and location of work completed: 171 I had sufficient time to inspect all materials used and placed. I was not employed by the contractor,:subcpacr or material vendor. Signed: Date:7-209 ' Print Name: h ' t , Cltv of Carlsbad 5 Final Building Inspection Dept: Building Engineering P, lanning CMWD St Lite Fire Plan Check #: PC070019 Date: 07/28/2008 Permit #: 0B070727 Permit Type: COMMIND Project Name: MAGELLAN AVIATION BLDG E Sub Type: INDUST 5472 SF HANGAR, Address: 2002 PALOMAR AIRPORT RD Lot: 0 Contact Person: MARK Phone: 7608024109 Sewer Dist: CA Water Dist: CA Inspected. By: Date !anr'A&Inspected:_______ Approved: frisapproved: Inspected Date By: . Inspected: . Approved: Disapproved: Inspected Date . 0 By: . Inspected: Approved: Disapproved: Comments: Ls~ C7o7z ,• City olCarlsbad Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Fire Plan Check #: PC070019 Date: 07/28/2008 Permit #: C6070727 Permit Type: COMMIND Project Name:• MAGELLAN AVIATION BLDG "E" Sub Type: INDUST 5472 SF HANGAR, Address: 2002 PALOMAR AIRPORT RD Lot: .0 Contact Person: MARK Phone: 7608024109 Sewer 01st: CA Water 01st: CA Inspe ted Date By: ttj Inspected: 7Zo Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Inspected . Date By: Inspected: Approved: _______ Disapproved: Comments: . ci o' do ( 1 . - - , it :City of Carlsbad I Final BuildingIInspection Dept: Building Engineering Planning CMWD St Lite ____ Plan Check #: PC070019 Date: 07/28/2008 Permit #: CB070727 Permit Type: COMMIND Project Name: MAGELLAN AVIATION BLDG "E Sub Type: INDUST 5472 SF HANGAR, Address: 2002 PALOMAR AIRPORT RD Lot: 0 Contact Person: MARK Phone: 7608024109 Sewer Dist: CA Water Dist: CA Inspected Date By: Inspected: 7//cs /n/ Approved: j/" Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Inspected Date By: Inspected: Approved: Disapproved: Comments: City of Carlsbad Bldg Inspection Request L%~*J__j . For: 01/26/2009 Permit# CB070727 Inspector Assignment: TP Title: MAGELLAN AVIATION BLDG "E" Description: 5472 SF HANGAR, Type: COMM IND Sub Type: IN DUST Phone: Job Address: 2002 PALOMAR AIRPORT RD Suite: Lot: 0 Location: Inspector: 11 OWNER COUNTY OF SAN DIEGOIPALOMAR AIRPORT Owner: Remarks: can you final this permit? Total Time: Requested By: CHRISTINE Entered By: CHRISTINE CD Description Act Comments - S / 19 Final Structural A'''' _r ,t 74 , 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Comments/Notices/Holds Associated PCRs/CVs Original PC# PC070019 PCRO8002 ISSUED MAGELLAN-BLDG E REVISIONTO; CONSTRUCTION TYPE PCRO8005 ISSUED MAGELLAN AVIATION BLDGS E&I; ELECTRICAL REVISIONS PCR08077 ISSUED MAGELLAN BLDG I-ADD ELEC RM; INSIDE OFFICE Inspection History Date Description 09/03/2008 89 Final combo 08/26/2008 89 Final combo 08/12/2008 89 Final combo 08/12/2008 89 Final combo 07/28/2008 89 Final Combo 03/11/2008 17 Interior Lath/Drywall 03/05/2008 17 Interior Lath/Drywall 02/26/2008 17 Interior Lath/Drywall 02/11/2008 14 Frame/Steel/Bolting/Welding 02/11/2008 17 Interior Lath/Drywall 02/08/2008 17 Interior Lath/Drywall Act Insp Comments AP TP NR TP CO TP CO TP Co MC NOTICE ATTACHED AP TP F. CAULK @ CLMNS NR TP N/COMP. F/CAULK © CLMNS AP TP 2ND LAYER FOR RATED WALL AP TP 1HR WALL INFILL AP TP SHAFT WALL BOARD IN 1 HR WALL NR TP CORR N/COMP. C City of Carlsbad Bldg Inspection Request Lu For: 01/26/2009 Permit# CB070727 Inspector Assignment: TP 02/06/2008 17 Interior Lath/Drywall Co TP 01/15/2008 31 Underground/Conduit-Wiring PA JM CONDUIT ONLY TO HANGAR 11/14/2007 11 Ftg/Foundation/Piers AP JM OK TO POUR W/FORM CERT FROM SURVEYOR - LIFER OK 10/31/2007 11 Ftg/Foundation/Piers NR TP N/COMP. 10/31/2007 12 Steel/Bond Beam NR TP 09/27/2007 21 Underground/Under Floor CO TP 4 WATSE WITH C/O SPEC 09/17/2007 21 Underground/Under Floor AP TP SEWER MAIN TO BLDG 09/17/2007 22 Sewer/Water Service AP TP P1 Special Inspector's Final Report Project Name: /Z'i'/ /4177 /2/. permit Number: .(O?ô?2 7 Project Address: %y0t.t4"City Insp. Name:________________ Special Inspector's Certification of Compliance TO THE BUILDING OFFICIAL: hereby certify that the following portions of the work at the above address which' required continuous inspection, and which I was employed to inspect, were inspected by me and comply with the provisions of the Building Code applicable thereto and were based upon approved plans, specifications, and the applicable workmanship provisions of the California Building Code, TYPE OF INSPECTION: li Slump/cylinders Rebar Placement IJ Tendon Placement l Welding/Structural Steel I Concrete Placement U Shot Crete ZI High-Strength Bolts U Precast/Post Tensioned Concrete U Masonry Cl Spray-Applied/Fire Proofing 0 Nondestructive Testing (NDT) U Other 0 Offsite Fabricator (if any): Description and location of work completed: IZE I had sufficient time to inspect all materials used and placed. I was not employed by the contractor,:suabc1ra-Zct r or material vendor. Signed: D ate: 72O9 Print Name: 10 City of Carlsbad Bldg Inspection Request For: 09/27/2007 Permit# CB070727 Inspector Assignment: Title: MAGELLAN AVIATION BLDG "E" Description: 5472 SF HANGAR, Type:COMMIND Sub Type: INDUST Phone: 7608465876 Job Address: 2002 PALOMAR AIRPORT RD Suite: Lot: 0 Location: Inspector: OWNER COUNTY OF SAN DIEGO/PALOMAR AIRPORT Owner: Remarks: Total Time: Requested By: PETER Entered By: CHRISTINE CD Description Act Comments 21 Underground/UnderFloor _-o i,,j,ri ce Comments/Notices/Holds Associated PCRs/CVs Original PC# PC070019 Inspection History Date Description Act Insp comments 09/17/2007 21 Underground/Under Floor AP TP SEWER MAIN TO BLDG 09/17/2007 22 Sewer/Water Service AP TP Structural Inspections 4 Special Inspection Company' 440 Tilling Way, El Cajon, CA 92020 Telephone: (619) 749-4912, Fax: (619) 749-5693, Cell: (619) 770-9559, Pager: (619) 907-3511 UI Inspection Report Project Name: MAGELLAN AVIATION BUILDING E Project Address: 2002 PALOMAR AIRPORT RD. Architect: Engineer:__________________________________ Contractor: M.W.CONSTRUCTION Page: 1 of 1 Permit #: CB 070727 File #: DSA#: Other: Report #: 01 INSRECTION . ..L. MATERhLDES:CRIPTIN •. INSPECTION CHECKLIST Structural Steel El H.S. Bolts H.S. Botts A325 Plans/Specs D Masonry Prisms Conc. PSI Clearances Concrete fl Mortar/Grout Grout PSI Positions E Fireproofing D Conc. Cylinders fl Mortar PSI fj Sizes o Other: Fireproof Steel 3/4" 0 Laps Other: BOLTS Other: fl Elect/Wire Consolidation Other: fl Other: Fireproof Torque Ft.Lbs: Other: fl Other: Other: Other: O Other: J Other: Other: Other: I-KbOKMLU SUlAL INl-'b(IIUN UN I HE INSIALLAlIUN ANU 1-ASTENING OF 3/4" HIGH STRENGTH BOLTED CONNECTIONS THROUGHOUT THE ROOF GIRDER TO GIRDER, GIRDER TO COLUMN CONNECTIONS. INSPECTED FASTENING OF BOLTS BY THE TURN OF THE NUT METHOD. FASTENING OF BOLTS IS COMPLETE. CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control. Inspector: MARIO BATTAGLIA Cert: City of SD #350 2/12/08 Signatke Date lnsp.. cv 1: 2/12/013 Day 2: I.. !Day..4................................................................................ Time Start: 9:00 Time Stop: 1:00 Copies of report submitted to: Structural Inspections A Special inspection Company" 440 Tilling Way, El Cajon, CA 92020 Telephone: (619)749-4912, Fax: (619) 749-5693, Cell: (619) 770-9559, Pager: (619) 907-3511 Inspection Report Project Name: MAGELLAN AVIATION BUILDING E Project Address:2002 PALOMAR AIRPORT RD. Architect: Engineer:__________________________________ Contractor: M.W.CONSTRUCTION Page: 1 of 1 Repoil #: 02 Permit #: CB 070727 File #: DSA #: Other: INSPECTION I MATERIAL SAMPLING QTY I MATERIAL DESCRIPTION INSPECTION CHECKLIST Structural Steel I El H.S. !301ts H.S. Bolts ED Plans/Specs O Masonry n Prisns . Conc. PSI fl Clearances fl Concrete EJ Mortar/Grout Grout PSI Positions EJ Fireproofing J Conc. Cylinders Mortar PSI Sizes Other: - Fireproof Steel 5/8" A.T. Laps Other: EPDXY 0 Other: . Elect/Wire fl Consolidation O Other: Other: Fireproof Torque Ft.Lbs: O Other: Other: Other: HILTLI HIT Other: Li Other: Other: Z Other: 8" EMBED EJ Other: PERFORMED CONTINUOUS SPECIAL INSPECTION ON THE INSTALLATION OF 8 TOTAL, 5/8" A.T. EPDXY ANCHOR BOLTS INTO FOUNDATION AT 2— ROLL UP DOOR COLUMNS. VERIFIED BOLT TYPES, SIZES, HOLE SIZES, DEPTH, LOCATION, CLEANLINESS AND EPDXY TYPE PRIOR TO INSTALLATION. CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections of the building codes. This report covers the Iocatjns QJthe}work inspected and does not constitute opinion or project control. I / - Inspector: MARIO BATTAGLIA Cert: City of SD #350 3/6/08 Signature. Date f98 .çy,2. ... ... Time Start: . 1:00 Tin ....................3:00 '-- ../':.....I LJ jrjr74 rr,* GEOCON I N C 0 R P0 RAT E D ,GEOTECHNICAL CONSULTANTS ara 6960 FLANDERS DRIVE • SAN DIEGO, CALIFORNIA 92121-2974 U TEL (858) 558-6900 • FAX (858) 558-6159 FOUNDATION OBSERVATION REPORT PROJECT NA LOCATION: FOUNDATIOI PROJECT NO. -O DATE: PLAN FILE NO. PERMIT NOS: FOUNDATION TYPE: CONVENTIONAL -O POST-TENSIONED 0 ADDITIONAL OBSERVATION REQUIRED , SUBSTANTIAL CONFORMANCE PURPOSE OF. OBSERVATION Verify soil conditions exposed are similar to those anticipated 'Verify footing excavations extend to minimum depth recommended in soil report C3 Verify foundation reinforcement complies with minimum recommended in soil report Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report Verify footings have been extended to an appropriate1 bearing strata El Other APPLICABLE SOIL TITLE.J1fWO-1 c4-77c DATE: SOIL REPORTRECOMMI IONS BASED ON: • . U Expansion Condition 0 VERY LOW 0 LOW 0 MEDIUM )HIGH El VERY HIGH El Fill Geometry El Other: MINIMUM FOUNDATION RECOMMENDATIONS: ' I.,Footing Depth: El 12 Inches El 18 Inches 24 Inches OTHER Footing Reinforcement: El No.4 T&B El 2-No.4 T&B El 2-No.5 T&B 0 Post-Tensioned OTHER: Interior Slab Reinforcement: 0 6x6-10/10 0 6x6-616 .0 No.3@241nche5 El No.3@181nches 0 Post-Tensioned Slab Bedding Material and Thickness: Vapor Barrier: Foundation Width: OBSERVATIONS: 'LSubstantial conformance with Soil Reports (see 'Purpose of Observation) 'tSubstantial conformance with Foundation Plans Identify ccCC)Co - kw r4 c-- Qk C*t Other _ )() 1VL71 , COMMENTS: ecr4 OLL)flex Act fi e±eirfl C-ecccyn (NOTE: SSYM7T ALL FOOTING EXCAVATIONS- WILL BE FIELEY'COPIES TO OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOIL MOISTURE CONTENT WILL BE MAINTAINED (3 GEOCON REPRESENTTIE- Frederick R. LePage P.O. Box 2796 Ramona, Ca 92065 (760) 525-1975 Cell (760) 789-3166 Fax Setback Certification November 19, 2007 To: John Mildbrandt, Building Inspector City of Carlsbad 1635 Faraday Drive Carlsbad, Ca 92008 Re: Building 'E' for Magellan Aviation @ Palomar Airport I have surveyed the existing form adjacent to the property line for the subject Building and I certify that it conforms to the minimum building setback per the approved plans. Sincerely, Fred LePage PLS 7524 cc 'EXR 12-31-2007) * \\ \ NO. 7524 .11 John RU Bucj±j INCORPORATED CONCRETE COMPRESSION TEST REPORT 01/08108 CLIENT: CHARLES E. MASON, JR.. LAB NO.: 7781-1-2-3 P.O. BOX 1696 FILE NO.: P-4883 CHINO, CALIFORNIA 91710 PROJECT: MAGELLAN AVIATION - 2006 PALOMAR AIRPORT ROAD, CARLSBAD, CALIFORNIA LOCATION IN STRUCTURE: DATE SAMPLED: SAMPLED AND MADE BY: (ASTMC I72. ASTM C 31) IDENTIFICATION MARK: DATE SAMPLES RECEIVED: NO. OF SAMPLES MADE: DESIGN PSI @ 28 DAYS: AIR CONTENT: SLAB/FOOTING AT BUILDING E 11f9/07 SLUMP-INCHES: 5 (MAX. ALLOWABLE) CLIENT SLUMP-INCHES: 5 (ACTUAL) (ASTM C 143) 1-ABC CONCRETE TEMP.: NA 11/26/07 (ASTM Cl 084) 3 MATERIAL MIX NO.: 3030067 3,000 TRUCK TICKET NO.: 255937 NA LOAD NO.: NA SAMPLE I.D. NO. AGE (DAYS) DIA. (IN.) AREA (SQ. IN.) COMPRESSIVE STRENGTH (ASTM C 39) LOAD (LBS.) (P.5.1.) TYPE OF FRACTURE 1 14 6.00 28.27 81,000 2,870 SIDE FRACTURES AT TOP OR BOTTOM 2 28 6.00 28.27 102,000 3,610 SIDE FRACTURES AT TOP OR BOTTOM 3 28 6.00 2827 107,000 3.780 SIDE FRACTURES AT TOP OR BOTTOM REMARKS: THE COMPRESSIVE STRENGTH EXCEEDS INDICATED DESIGN STRENGTH. COPIES TO: (1) CLIENT (1) AL SHANKLE CONSTRUCTION CO. GEOTECHNICAL ENGINEERS • TESTING AND INSPECTION 2257 South Lilac Ave., Bloomington, CA 92316-2907 81oornington (909) 877-1321 Riverside (909) 783-1910 Fax (909) 877-6210 H2A Architects Hawkins Hawkins Anderson, LLP 2194 Carmel Valley Road Del Mar, California 92014 858.755.5009 fax 858.755.1236 1-12Aarchitects.com San Diego Del Mar July 31, 2008 RE: Magellan Aviation Hangar E' (CB PC07-0019) 2002 Palomar Airport Road Carlsbad, Ca 92008 To Whom It May Concern, The panic hardware on the pedestrian door in Hangar 'E', as shown on the permitted set of plans CB PC07-0019, is not required by Building Code. The only requirement necessary per Section 1003.3.1.8 is that Regardless of the Occupant Load served, exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.' As long as the hardware installed on site satisfies the above condition, it meets the requirement of the Building Code. See attached sheet A4.0 for revised door schedule. Please feel free to contact me if you have any questions or concerns. Howard L. Anderson, Architect ~ "I . - 858.755.5009 x1 01 howard@h2aarchitects.com AN C 92 Ln T. 024 Or cp'-'Y